b52ada86604f2654c6429cc6f767cb370ec86c0d
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14    1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
15    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
16    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
17    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19    1. [Requirements](#requirements)
20    1. [Addressing](#addressing)
21    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24    1. [Server Types](#server-types)
25    1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29       1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
30       1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
31       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32       1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
33       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34       1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
35       1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
36       1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
37       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
38       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
39       1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
40    1. [Per Testbed Wiring](#per-testbed-wiring)
41       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42       1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
43       1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
44       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45       1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
46       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
48       1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
49       1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
50       1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
51       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
52       1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
53       1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
54 1. [Inventory](#inventory)
55    1. [Appliances](#appliances)
56    1. [Arm Servers](#arm-servers)
57    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
58    1. [Network Interface Cards](#network-interface-cards)
59    1. [Pluggables and Cables](#pluggables-and-cables)
60    1. [Other Parts](#other-parts)
61
62 ## Purpose
63
64 This note includes specification of the physical testbed infrastructure
65 hosted by LFN FD.io CSIT project.
66
67 ## Testbeds Overview
68
69 ### Summary List
70
71 ```
72  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
73  1. 1-Node-Haswell     nomad  hsw   ---   4    4    0    4    0    0    0    0    0    0    0    0
74  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0
75  3. 1-Node-ThunderX2   perf   tx2   na    1    1    .5   0    .5   0    0    0    1    0    0    0
76  4. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0
77  5. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    1    0
78  6. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0    0
79  7. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0
80  8. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0
81  9. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    6    0
82 10. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0
83 11. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0
84 12. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0
85 13. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0
86 14. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    2
87                                  Totals: 25   31   15    4   19    1    2    3    3    2    7    2
88 ```
89
90 ### 1-Node-Skylake Xeon Intel (1n-skx)
91
92 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
93 ports connected back-to-back ([Server Types](#server-types)).
94 Used for FD.io VPP_Device functional driver tests.
95
96 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
97
98 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC
99 ports connected back-to-back ([Server Types](#server-types)).
100 Used for FD.io VPP_Device functional driver tests.
101
102 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
103
104 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
105 NIC ports connected back-to-back ([Server Types](#server-types)).
106
107 Used for FD.io VPP_Device functional driver tests.
108
109 ### 2-Node-Skylake Xeon Intel (2n-skx)
110
111 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
112 (Server-Type-B2) connected in a 2-node circular topology
113 ([Server Types](#server-types)).
114 Used for FD.io performance tests.
115
116 ### 2-Node-Denverton Atom Intel (2n-dnv)
117
118 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
119 TG (Server-Type-B2) connected in a 2-node circular topology
120 ([Server Types](#server-types)).
121 Used for FD.io performance tests.
122
123 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
124
125 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
126 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
127 circular topology ([Server Types](#server-types)).
128 Used for FD.io TCP/IP and HTTP performance tests.
129
130 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
131
132 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
133 one TG (Server-Type-C3) connected in a 2-node circular topology
134 ([Server Types](#server-types)).
135 Used for FD.io performance tests.
136
137 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
138
139 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
140 one TG (Server-Type-D2) connected in a 2-node circular topology
141 ([Server Types](#server-types)).
142 Used for FD.io performance tests.
143
144 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
145
146 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) and
147 one TG (Server-Type-B12) connected in a 2-node circular topology
148 ([Server Types](#server-types)).
149 Used for FD.io performance tests.
150
151 ### 3-Node-Haswell Xeon Intel (3n-hsw)
152
153 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
154 TG (Server-Type-A2) connected in a 3-node circular topology
155 ([Server Types](#server-types)).
156 Used for FD.io performance tests.
157
158 ### 3-Node-Skylake Xeon Intel (3n-skx)
159
160 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
161 TG (Server-Type-B2) connected in a 3-node circular topology.
162 Used for FD.io performance tests.
163
164 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
165
166 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
167 TG (Server-Type-B12) connected in a 3-node circular topology
168 ([Server Types](#server-types)).
169 Used for FD.io performance tests.
170
171 ### 3-Node-Rangeley Atom Testbeds
172
173 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
174 TG (Server-Type-2) connected in a 3-node circular topology
175 ([Server Types](#server-types)).
176 Used for FD.io performance tests.
177
178 ## Server Management
179
180 ### Requirements
181
182 For management purposes, each server must have following two ports
183 connected to the management network:
184
185 ```
186 - 1GE IPMI port
187   - IPMI - Intelligent Platform Management Interface.
188   - Required for access to embedded server management with WebUI, CLI,
189     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
190 - 1GE/10GE/40GE management port
191   - hostOS management port for general system management.
192 ```
193
194 ### Addressing
195
196 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
197 Management port, which are connected to two different VLANs.
198
199 ```
200 1. LOM (IPMI) VLAN:
201     - Subnet: 10.30.50.0/24
202     - Gateway: 10.30.50.1
203     - Broadcast: 10.30.50.255
204     - DNS1: 199.204.44.24
205     - DNS2: 199.204.47.54
206 2. Management Vlan:
207     - Subnet: 10.30.51.0/24
208     - Gateway: 10.30.51.1
209     - Broadcast: 10.30.51.255
210     - DNS1: 199.204.44.24
211     - DNS2: 199.204.47.54
212 ```
213
214 To access these hosts, VPN connection is required.
215
216 ### LOM (IPMI) VLAN IP Addresses
217
218 Name         | Comment
219 ------------ | -------
220 10.30.50.0   | network
221 10.30.51.1   | Router
222 10.30.50.2   | LF Reserved
223 10.30.50.3   | LF Reserved
224 10.30.50.4   | LF Reserved
225 10.30.50.5   | LF Reserved
226 10.30.50.6   | LF Reserved
227 10.30.50.7   | LF Reserved
228 10.30.50.8   | LF Reserved
229 10.30.50.9   | LF Reserved
230 10.30.50.10  | LF Reserved
231 10.30.50.11  | LF Reserved
232 10.30.50.12  | LF Reserved
233 10.30.50.13  | LF Reserved
234 10.30.50.14  | LF Reserved
235 10.30.50.15  | LF Reserved
236 10.30.50.28  | s41-nomad
237 10.30.50.29  | s39-nomad
238 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
239 10.30.50.30  | s40-nomad
240 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
241 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
242 10.30.50.32  | s42-nomad
243 10.30.50.33  | s43-nomad
244 10.30.50.34  | s44-nomad
245 10.30.50.35  | s45-nomad
246 10.30.50.36  | s17-t33-sut1
247 10.30.50.37  | s18-t33-sut2
248 10.30.50.38  | fdio-marvell-dev
249 10.30.50.39  | s53-nomad
250 10.30.50.40  | s54-nomad
251 10.30.50.41  | s3-t21-sut1
252 10.30.50.42  | s4-t21-tg1
253 10.30.50.43  | s11-t31-sut1
254 10.30.50.44  | s12-t31-sut2
255 10.30.50.45  | s13-t31-tg1
256 10.30.50.46  | s19-t33t34-tg1
257 10.30.50.47  | s1-t11-sut1
258 10.30.50.48  | s2-t12-sut1
259 10.30.50.49  | s5-t22-sut1
260 10.30.50.50  | s6-t22-tg1
261 10.30.50.51  | s7-t23-sut1
262 10.30.50.52  | s8-t23-tg1
263 10.30.50.53  | s9-t24-sut1
264 10.30.50.54  | s10-t24-tg1
265 10.30.50.55  | s14-t32-sut1
266 10.30.50.56  | s15-t32-sut2
267 10.30.50.57  | s16-t32-tg1
268 10.30.50.58  | s25-t25-sut1
269 10.30.50.59  | s26-t25-tg1
270 10.30.50.65  | s52-nomad
271 10.30.50.66  | s51-nomad
272 10.30.50.67  | s49-nomad
273 10.30.50.68  | s50-nomad
274 10.30.50.69  | s27-t34-sut1
275 10.30.50.70  | s55-t36-sut1
276 10.30.50.71  | s56-t37-sut1
277 10.30.50.255 | Broadcast
278 n/a          | s20-t34-sut1
279 n/a          | s21-t34-sut2
280 10.30.55.0   | network
281 10.30.55.1   | Router
282 10.30.55.10  | s28-t26t35-tg1
283 10.30.55.11  | s29-t26-sut1
284 10.30.55.12  | s30-t35-sut1
285 10.30.55.13  | s31-t35-sut2
286 10.30.55.14  | s46-nomad
287 10.30.55.15  | s47-nomad
288 10.30.55.16  | s48-nomad
289 10.30.55.17  | s57-nomad
290 10.30.55.18  | s33-t27-sut1
291 10.30.55.19  | s34-t27-tg1
292 10.30.55.20  | s35-t28-sut1
293 10.30.55.21  | s36-t28-tg1
294 10.30.55.22  | s37-t29-sut1
295 10.30.55.23  | s38-t29-tg1
296 10.30.55.24  | s60-t210-sut1
297 10.30.55.25  | s61-t210-tg1
298 10.30.55.255 | Broadcast
299
300 ### Management VLAN IP Addresses
301
302 Name                      | Comment
303 ------------------------- | -------
304 10.30.51.0                | network
305 10.30.51.1                | Router
306 10.30.51.2                | LF Reserved
307 10.30.51.3                | LF Reserved
308 10.30.51.4                | LF Reserved
309 10.30.51.5                | LF Reserved
310 10.30.51.6                | LF Reserved
311 10.30.51.7                | LF Reserved
312 10.30.51.8                | LF Reserved
313 10.30.51.15               | LF Reserved
314 10.30.51.28               | s41-nomad
315 10.30.51.29               | s39-nomad
316 10.30.51.30               | s40-nomad
317 10.30.51.32               | s42-nomad
318 10.30.51.33               | s43-nomad
319 10.30.51.34               | s44-nomad
320 10.30.51.35               | s45-nomad
321 10.30.51.36               | s17-t33-sut1
322 10.30.51.37               | s18-t33-sut2
323 10.30.51.38               | fdio-marvell-dev
324 10.30.51.39               | s53-nomad
325 10.30.51.40               | s54-nomad
326 10.30.51.44               | s3-t21-sut1
327 10.30.51.45               | s4-t21-tg1
328 10.30.51.46               | s11-t31-sut1
329 10.30.51.47               | s12-t31-sut2
330 10.30.51.48               | s13-t31-tg1
331 10.30.51.49               | s19-t33t34-tg1
332 10.30.51.50               | s1-t11-sut1
333 10.30.51.51               | s2-t12-sut1
334 10.30.51.52               | s5-t22-sut1
335 10.30.51.53               | s6-t22-tg1
336 10.30.51.54               | s7-t23-sut1
337 10.30.51.55               | s8-t23-tg1
338 10.30.51.56               | s9-t24-sut1
339 10.30.51.57               | s10-t24-tg1
340 10.30.51.58               | s14-t32-sut1
341 10.30.51.59               | s15-t32-sut2
342 10.30.51.60               | s16-t32-tg1
343 10.30.51.61               | s25-t25-sut1
344 10.30.51.62               | s26-t25-tg1
345 10.30.51.65               | s52-nomad
346 10.30.51.66               | s51-nomad
347 10.30.51.67               | s49-nomad
348 10.30.51.68               | s50-nomad
349 10.30.51.69               | s27-t34-sut1
350 10.30.51.70               | s55-t36-sut1
351 10.30.51.71               | s56-t37-sut1
352 10.30.51.72-10.30.51.254  | FREE
353 10.30.51.255              | Broadcast
354 10.32.8.0                 | network
355 10.32.8.1                 | Router
356 10.32.8.10                | s28-t26t35-tg1
357 10.32.8.11                | s29-t26-sut1
358 10.32.8.12                | s30-t35-sut1
359 10.32.8.13                | s31-t35-sut2
360 10.32.8.14                | s46-nomad
361 10.32.8.15                | s47-nomad
362 10.32.8.16                | s48-nomad
363 10.32.8.17                | s57-nomad
364 10.32.8.18                | s33-t27-sut1
365 10.32.8.19                | s34-t27-tg1
366 10.32.8.20                | s35-t28-sut1
367 10.32.8.21                | s36-t28-tg1
368 10.32.8.22                | s37-t29-sut1
369 10.32.8.23                | s38-t29-tg1
370 10.32.8.24                | s60-t210-sut1
371 10.32.8.25                | s61-t210-tg1
372 10.32.8.255               | Broadcast
373
374 ## Server Specifications
375
376 ### Server Types
377
378 FD.io CSIT lab contains following server types:
379 ```
380 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
381     - Quantity: 6 servers.
382     - Physical connectivity:
383         - CIMC and host management ports.
384         - NIC ports connected in 3-node topologies.
385     - Main HW configuration:
386         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
387         - Processors: 2* E5-2699v3 2.3 GHz.
388         - RAM Memory: 16* 32GB DDR4-2133MHz.
389         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
390     - NICs configuration:
391         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
392             - PCIe Slot1: empty.
393             - PCIe Slot2: empty.
394             - PCIe Slot3: empty.
395         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
396             - PCIe Slot4: empty.
397             - PCIe Slot5: empty.
398             - PCIe Slot6: empty
399         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
400 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
401     - Quantity: 3 servers.
402     - Physical connectivity:
403         - CIMC and host management ports.
404         - NIC ports connected in 3-node topologies.
405     - Main HW configuration:
406         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
407         - Processors: 2* E5-2699v3 2.3 GHz.
408         - RAM Memory: 16* 32GB DDR4-2133MHz.
409         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
410     - NICs configuration:
411         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
412             - PCIe Slot1: empty.
413             - PCIe Slot2: empty.
414             - PCIe Slot3: empty.
415         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
416             - PCIe Slot4: empty.
417             - PCIe Slot5: empty.
418             - PCIe Slot6: empty
419         - MLOM slot: empty.
420 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
421     - Quantity: 3 servers.
422     - Physical connectivity:
423         - CIMC and host management ports.
424         - no NIC ports, standalone setup.
425     - Main HW configuration:
426         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
427         - Processors: 2* E5-2699v3 2.3 GHz.
428         - RAM Memory: 16* 32GB DDR4-2133MHz.
429         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
430     - NICs configuration:
431         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
432             - no cards.
433         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
434             - no cards.
435         - MLOM slot: empty.
436 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
437     - Quantity: ---
438     - Physical connectivity:
439         - IPMI and host management ports.
440         - NIC ports connected into 2-node and 3-node topologies.
441     - Main HW configuration:
442         - Chassis: SuperMicro SYS-7049GP-TRT.
443         - Motherboard: SuperMicro X11DPG-QT.
444         - Processors: 2* Intel Platinum 8180 2.5 GHz.
445         - RAM Memory: 16* 16GB DDR4-2666MHz.
446         - Disks: 2* 1.6TB 6G SATA SSD.
447     - NICs configuration:
448         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
449             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
450             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
451             - PCIe Slot9 5e:00.xx: empty.
452         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
453             - PCIe Slot6 86:00.xx: empty.
454             - PCIe Slot8 af:00.xx: empty.
455             - PCIe Slot10 d8:00.xx: empty.
456 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
457     - Quantity: ---
458     - Physical connectivity:
459         - IPMI and host management ports.
460         - NIC ports connected into 2-node and 3-node topologies.
461     - Main HW configuration:
462         - Chassis: SuperMicro SYS-7049GP-TRT.
463         - Motherboard: SuperMicro X11DPG-QT.
464         - Processors: 2* Intel Platinum 8180 2.5 GHz.
465         - RAM Memory: 16* 16GB DDR4-2666MHz.
466         - Disks: 2* 1.6TB 6G SATA SSD.
467     - NICs configuration:
468         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
469             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
470             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
471             - PCIe Slot9 5e:00.xx: empty.
472         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
473             - PCIe Slot6 86:00.xx: empty.
474             - PCIe Slot8 af:00.xx: empty.
475             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
476 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
477     - Quantity: 2
478     - Physical connectivity:
479         - IPMI(?) and host management ports.
480         - NIC ports connected into 3-node topology.
481     - Main HW configuration:
482         - Chassis: Huawei TaiShan 2280.
483         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
484         - RAM Memory: 8* 16GB DDR4-2400MT/s
485         - Disks: 1* 4TB SATA HDD
486     - NICs configuration:
487         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
488         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
489 7. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
490     - Quantity: TBD based on testbed allocation.
491     - Physical connectivity:
492         - Management: serial Port (usb) for console
493         - NIC ports connected into 2-node.
494     - Main HW configuration:
495         - Chassis: Netgate XG-2758-1u
496         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
497         - RAM Memory: 16GB ECC
498         - Disks: 150 GB
499     - NICs configuration:
500         - 2x 10Gb Intel 82599ES
501         - 4x 1GB Intel I354
502 8. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
503     - Quantity: 2.
504     - Physical connectivity:
505         - IPMI and host management ports.
506         - NIC ports connected into 1-node topologies.
507     - Main HW configuration:
508         - Chassis: SuperMicro SYS-7049GP-TRT.
509         - Motherboard: SuperMicro X11DPG-QT.
510         - Processors: 2* Intel Platinum 8180 2.5 GHz.
511         - RAM Memory: 16* 16GB DDR4-2666MHz.
512         - Disks: 2* 1.6TB 6G SATA SSD.
513     - NICs configuration:
514         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
515             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
516             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
517             - PCIe Slot9 5e:00.xx: empty.
518         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
519             - PCIe Slot6 86:00.xx: empty.
520             - PCIe Slot8 af:00.xx: empty.
521             - PCIe Slot10 d8:00.xx: empty.
522 9. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
523     - Quantity: 1.
524     - Physical connectivity:
525         - Host management interface: 10/100/1000-BaseT.
526         - 8-port 10GE SFP+ integrated NIC.
527     - Main HW configuration:
528         - Chassis: PS10GE4NG.
529         - Motherboard: SuperMicro X11DPG-QT.
530         - Processors: Quad-Core, Intel Processor.
531         - HW accelerators: FPGA offload.
532         - RAM Memory: 64GB.
533         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
534         - Physical Interfaces: 4 * 10GE SFP+.
535         - Operating System: Native IxOS.
536     - Interface configuration:
537         - Port-1: 10GE SFP+.
538         - Port-2: 10GE SFP+.
539         - Port-3: 10GE SFP+.
540         - Port-4: 10GE SFP+.
541 10. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
542     - Quantity: 1.
543     - Physical connectivity:
544         - IPMI and host management ports.
545         - NIC ports.
546     - Main HW configuration:
547         - Chassis: SuperMicro SYS-7049GP-TRT.
548         - Motherboard: SuperMicro X11DPG-QT.
549         - Processors: 2* Intel Platinum 8180 2.5 GHz.
550         - RAM Memory: 16* 16GB DDR4-2666MHz.
551         - Disks: 2* 1.6TB 6G SATA SSD.
552     - NICs configuration:
553         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
554             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
555             - PCIe Slot4 3b:00.xx: empty.
556             - PCIe Slot9 5e:00.xx: empty.
557         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
558             - PCIe Slot6 86:00.xx: empty.
559             - PCIe Slot8 af:00.xx: empty.
560             - PCIe Slot10 d8:00.xx: empty.
561 11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
562     - Quantity: 1
563     - Physical connectivity:
564         - IPMI and host management ports.
565         - NIC ports connected into 1-node topologies.
566     - Main HW configuration:
567         - Chassis: Gigabyte R181-T90 1U
568         - Motherboard: MT91-FS1
569         - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
570         - RAM Memory: 4* 32GB RDIMM
571         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
572     - NICs configuration:
573         - Numa0:
574             - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
575         - Numa1:
576             - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
577 12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
578     - Quantity: 4
579     - Physical connectivity:
580         - IPMI and host management ports.
581         - NIC ports.
582     - Main HW configuration:
583         - Chassis: SuperMicro SYS-E300-9A
584         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
585         - RAM Memory: 32GB ECC
586         - Disks: 480 GB
587     - NICs configuration:
588         - 2x 10Gb Intel x553 fiber ports
589         - 2x 10Gb Intel x553 copper ports
590         - 4x 1GB Intel I350 ports
591 13. Server-Type-B11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
592     - Quantity: 2
593     - Physical connectivity:
594         - IPMI and host management ports.
595         - NIC ports connected into 1-node topologies.
596     - Main HW configuration:
597         - Chassis: GIGABYTE Rack Mount
598         - Motherboard: MT91-FS4-00
599         - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
600         - RAM Memory: 16 * 16GB DIMM
601         - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
602     - NICs configuration:
603         - Numa0:
604             - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
605             - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
606         - Numa1:
607             - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
608             - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
609 14. Server-Type-B12: Purpose - Skylake Xeon TG for FD.io performance testing.
610     - Quantity: ---
611     - Physical connectivity:
612         - IPMI and host management ports.
613         - NIC ports connected into 2-node and 3-node topologies.
614     - Main HW configuration:
615         - Chassis: SuperMicro SYS-7049GP-TRT.
616         - Motherboard: SuperMicro X11DPG-QT.
617         - Processors: 2* Intel Platinum 8180 2.5 GHz.
618         - RAM Memory: 16* 16GB DDR4-2666MHz.
619         - Disks: 2* 1.6TB 6G SATA SSD.
620     - NICs configuration:
621         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
622             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
623             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
624             - PCIe Slot9 5e:00.xx: empty.
625         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
626             - PCIe Slot6 86:00.xx: empty.
627             - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
628             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
629
630 15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
631     - Quantity: 1.
632     - Physical connectivity:
633         - IPMI and host management ports.
634         - NIC ports connected into 1-node testbed topologies.
635     - Main HW configuration:
636         - Chassis: SuperMicro SYS-7049GP-TRT.
637         - Motherboard: SuperMicro X11DPG-QT.
638         - Processors: 2* Intel Platinum 8280 2.7 GHz.
639         - RAM Memory: 12* 16GB DDR4-2933.
640         - Disks: 2* 1.92TB SATA SSD.
641     - NICs configuration:
642         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
643             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
644             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
645             - PCIe Slot9 5e:00.xx: empty.
646         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
647             - PCIe Slot6 86:00.xx: empty.
648             - PCIe Slot8 af:00.xx: empty.
649             - PCIe Slot10 d8:00.xx: empty.
650 16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
651     - Quantity: 3
652     - Physical connectivity:
653         - IPMI and host management ports.
654         - NIC ports connected into 2-node testbed topologies.
655     - Main HW configuration:
656         - Chassis: SuperMicro SYS-7049GP-TRT.
657         - Motherboard: SuperMicro X11DPG-QT.
658         - Processors: 2* Intel Gold 6252N 2.3 GHz.
659         - RAM Memory: 12* 16GB DDR4-2933.
660         - Disks: 2* 1.92TB SATA SSD.
661     - NICs configuration:
662         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
663             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
664             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
665             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
666         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
667             - PCIe Slot6 86:00.xx: empty.
668             - PCIe Slot8 af:00.xx: empty.
669             - PCIe Slot10 d8:00.xx: empty.
670 17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
671     - Quantity: 3.
672     - Physical connectivity:
673         - IPMI and host management ports.
674         - NIC ports connected into 2-node testbed topologies.
675     - Main HW configuration:
676         - Chassis: SuperMicro SYS-7049GP-TRT.
677         - Motherboard: SuperMicro X11DPG-QT.
678         - Processors: 2* Intel Platinum 8280 2.7 GHz.
679         - RAM Memory: 12* 16GB DDR4-2933.
680         - Disks: 2* 1.92TB SATA SSD.
681     - NICs configuration:
682         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
683             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
684             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
685             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
686         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
687             - PCIe Slot6 86:00.xx: empty.
688             - PCIe Slot8 af:00.xx: empty.
689             - PCIe Slot10 d8:00.xx: empty.
690 18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
691     - Quantity: 3.
692     - Physical connectivity:
693         - CIMC and host management ports.
694         - no NIC ports, standalone setup.
695     - Main HW configuration:
696         - Chassis: SuperMicro 1029P-WTRT.
697         - Motherboard: SuperMicro X11DDW-NT.
698         - Processors: 2* Intel Platinum 8280 2.7 GHz.
699         - RAM Memory: 12* 16GB DDR4-2933.
700         - Disks: 4* 1.92TB SATA SSD.
701     - NICs configuration:
702         - Numa0:
703             - no cards.
704         - Numa1:
705             - no cards.
706 19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
707     - Quantity: 1.
708     - Physical connectivity:
709         - IPMI and host management ports.
710         - NIC ports connected into 2-node testbed topologies.
711     - Main HW configuration:
712         - Chassis: SuperMicro AS-1114S-WTRT
713         - Processors: 1* AMD EPYC 7532 2.4 GHz.
714         - RAM Memory: 8* 32GB DDR4-2933.
715         - Disks: 1* 1TB SATA SSD.
716     - NICs configuration:
717         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
718             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
719             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
720             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
721 20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
722     - Quantity: 1.
723     - Physical connectivity:
724         - IPMI and host management ports.
725         - NIC ports connected into 2-node testbed topologies.
726     - Main HW configuration:
727         - Chassis: SuperMicro AS-1114S-WTRT
728         - Processors: 1* AMD EPYC 7532 2.4 GHz.
729         - RAM Memory: 8* 32GB DDR4-2933.
730         - Disks: 1* 1TB SATA SSD.
731     - NICs configuration:
732         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
733             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
734             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
735             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
736 ```
737
738 ### Naming Convention
739
740 Following naming convention is used within this page to specify physical
741 connectivity and wiring across defined CSIT testbeds:
742
743 ```
744 - testbedname: testbedN.
745 - hostname:
746     - traffic-generator: tN-tgW.
747     - system-under-testX: tN-sutX.
748 - portnames:
749     - tN-tgW-cY/pZ.
750     - tN-sutX-cY/pZ.
751 - where:
752     - N - testbed number.
753     - tgW - server acts as traffic-generator with W index.
754     - sutX - server acts as system-under-test with X index.
755     - Y - PCIe slot number denoting a NIC card number within the host.
756     - Z - port number on the NIC card.
757 ```
758
759 ## Testbeds Configuration
760
761 ### Per Testbed Server Allocation and Naming
762
763 #### 1-Node-Skylake Servers (1n-skx) PROD
764
765 ```
766 - SUT [Server-Type-B6]:
767     - testbedname: testbed11.
768     - hostname: s1-t11-sut1.
769     - IPMI IP: 10.30.50.47
770     - Host IP: 10.30.51.50
771     - portnames:
772         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
773         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
774         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
775         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
776         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
777         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
778         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
779         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
780 - SUT [Server-Type-B6]:
781     - testbedname: testbed12.
782     - hostname: s2-t12-sut1.
783     - IPMI IP: 10.30.50.48
784     - Host IP: 10.30.51.51
785     - portnames:
786         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
787         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
788         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
789         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
790         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
791         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
792         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
793         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
794 ```
795
796 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
797
798 ```
799 - SUT [Server-Type-B11]:
800     - testbedname: testbed36
801     - hostname: s55-t36-sut1
802     - IPMI IP: 10.30.50.70
803     - Host IP: 10.30.51.70
804     - portnames:
805         - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
806         - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
807         - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
808         - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
809         - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
810         - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
811         - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
812         - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
813 - SUT [Server-Type-B11]:
814     - testbedname: testbed37
815     - hostname: s56-t37-sut1
816     - IPMI IP: 10.30.50.71
817     - Host IP: 10.30.51.71
818     - portnames:
819         - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
820         - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
821         - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
822         - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
823         - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
824         - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
825         - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
826         - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
827 ```
828
829 #### 1-Node-Cascadelake Servers (1n-clx) PROD
830
831 ```
832 - SUT [Server-Type-C1]:
833     - testbedname: testbed11.
834     - hostname: s32-t14-sut1.
835     - IPMI IP: 10.30.55.17
836     - Host IP: 10.32.8.17
837     - portnames:
838         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
839         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
840         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
841         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
842         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
843         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
844         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
845         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
846 ```
847
848 #### 2-Node-Skylake Servers (2n-skx) PROD
849
850 ```
851 - SUT [Server-Type-B1]:
852     - testbedname: testbed21.
853     - hostname: s3-t21-sut1.
854     - IPMI IP: 10.30.50.41
855     - Host IP: 10.30.51.44
856     - portnames:
857         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
858         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
859         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
860         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
861         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
862         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
863 - TG [Server-Type-B2]:
864     - testbedname: testbed21.
865     - hostname: s4-t21-tg1.
866     - IPMI IP: 10.30.50.42
867     - Host IP: 10.30.51.45
868     - portnames:
869         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
870         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
871         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
872         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
873         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
874         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
875 - SUT [Server-Type-B1]:
876     - testbedname: testbed22.
877     - hostname: s5-t22-sut1.
878     - IPMI IP: 10.30.50.49
879     - Host IP: 10.30.51.52
880     - portnames:
881         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
882         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
883         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
884         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
885         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
886         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
887 - TG [Server-Type-B2]:
888     - testbedname: testbed22.
889     - hostname: s6-t22-tg1.
890     - IPMI IP: 10.30.50.50
891     - Host IP: 10.30.51.53
892     - portnames:
893         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
894         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
895         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
896         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
897         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
898         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
899 - SUT [Server-Type-B1]:
900     - testbedname: testbed23.
901     - hostname: s7-t23-sut1.
902     - IPMI IP: 10.30.50.51
903     - Host IP: 10.30.51.54
904     - portnames:
905         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
906         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
907         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
908         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
909         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
910         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
911 - TG [Server-Type-B2]:
912     - testbedname: testbed23.
913     - hostname: s8-t23-tg1.
914     - IPMI IP: 10.30.50.52
915     - Host IP: 10.30.51.55
916     - portnames:
917         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
918         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
919         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
920         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
921         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
922         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
923 - SUT [Server-Type-B1]:
924     - testbedname: testbed24.
925     - hostname: s9-t24-sut1.
926     - IPMI IP: 10.30.50.53
927     - Host IP: 10.30.51.56
928     - portnames:
929         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
930         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
931         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
932         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
933         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
934         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
935 - TG [Server-Type-B2]:
936     - testbedname: testbed24.
937     - hostname: s10-t24-tg1.
938     - IPMI IP: 10.30.50.54
939     - Host IP: 10.30.51.57
940     - portnames:
941         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
942         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
943         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
944         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
945         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
946         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
947 ```
948
949 #### 2-Node-Denverton Servers (2n-dnv) PROD
950
951 Note: ServerB28 (TG) is shared between testbed26 & testbed35
952
953 ```
954 - TG [Server-Type-B2]:
955     - testbednames: testbed26 and testbed35.
956     - hostname: s28-t26t35-tg1.
957     - IPMI IP: 10.30.55.10
958     - Host IP: 10.32.8.10
959     - portnames:
960         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
961         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
962         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
963         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
964         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
965         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
966         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
967         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
968         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
969         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
970         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
971         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
972 - SUT [Server-Type-B10]:
973     - testbednames: testbed26.
974     - hostname: s29-t26-sut1.
975     - IPMI IP: 10.30.55.11
976     - Host IP: 10.32.8.11
977     - portnames:
978         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
979         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
980         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
981         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
982 ```
983
984 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
985
986 ```
987 - SUT [Server-Type-B8]:
988     - testbedname: testbed25.
989     - hostname: s25-t25-sut1.
990     - IPMI IP: 10.30.50.58
991     - Host IP: 10.30.51.61
992     - portnames:
993         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
994         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
995         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
996         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
997 - TG [Server-Type-B7]:
998     - testbedname: testbed25.
999     - hostname: s26-t25-tg1.
1000     - IPMI IP: 10.30.50.59
1001     - Host IP: 10.30.51.62
1002     - portnames:
1003         - s26-t25-tg1-p1 - 10GE-port1.
1004         - s26-t25-tg1-p2 - 10GE-port2.
1005         - s26-t25-tg1-p3 - 10GE-port3.
1006         - s26-t25-tg1-p4 - 10GE-port4.
1007 ```
1008
1009 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1010
1011 ```
1012 - SUT [Server-Type-C2]:
1013     - testbedname: testbed27.
1014     - hostname: s33-t27-sut1.
1015     - IPMI IP: 10.30.55.18
1016     - Host IP: 10.32.8.18
1017     - portnames:
1018         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1019         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1020         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1021         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1022         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1023         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1024         - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1025         - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1026         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1027         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1028 - TG [Server-Type-C3]:
1029     - testbedname: testbed27.
1030     - hostname: s34-t27-tg1.
1031     - IPMI IP: 10.30.55.19
1032     - Host IP: 10.32.8.19
1033     - portnames:
1034         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1035         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1036         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1037         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1038         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1039         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1040         - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1041         - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1042         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1043         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1044 - SUT [Server-Type-C2]:
1045     - testbedname: testbed28.
1046     - hostname: s35-t28-sut1.
1047     - IPMI IP: 10.30.55.20
1048     - Host IP: 10.32.8.20
1049     - portnames:
1050         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1051         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1052         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1053         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1054         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1055         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1056         - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1057         - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1058         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1059         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1060 - TG [Server-Type-C3]:
1061     - testbedname: testbed28.
1062     - hostname: s36-t28-tg1.
1063     - IPMI IP: 10.30.55.21
1064     - Host IP: 10.32.8.21
1065     - portnames:
1066         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1067         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1068         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1069         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1070         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1071         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1072         - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1073         - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1074         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1075         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1076 - SUT [Server-Type-C2]:
1077     - testbedname: testbed29.
1078     - hostname: s37-t29-sut1.
1079     - IPMI IP: 10.30.55.22
1080     - Host IP: 10.32.8.22
1081     - portnames:
1082         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1083         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1084         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1085         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1086         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1087         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1088         - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1089         - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1090         - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1091         - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1092 - TG [Server-Type-C3]:
1093     - testbedname: testbed29.
1094     - hostname: s38-t29-tg1.
1095     - IPMI IP: 10.30.55.23
1096     - Host IP: 10.32.8.23
1097     - portnames:
1098         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1099         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1100         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1101         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1102         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1103         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1104         - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1105         - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1106         - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1107         - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1108 ```
1109
1110 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1111
1112 ```
1113 - SUT [Server-Type-D1]:
1114     - testbedname: testbed210.
1115     - hostname: s60-t210-sut1.
1116     - IPMI IP: 10.30.55.24
1117     - Host IP: 10.32.8.24
1118     - portnames:
1119         - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1120         - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1121         - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1122         - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1123         - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1124         - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1125         - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1126         - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1127 - TG [Server-Type-D2]:
1128     - testbedname: testbed210.
1129     - hostname: s61-t210-tg1.
1130     - IPMI IP: 10.30.55.25
1131     - Host IP: 10.32.8.25
1132     - portnames:
1133         - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1134         - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1135         - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1136         - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1137         - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1138         - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1139         - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1140         - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1141 ```
1142
1143 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1144
1145 Note: Server19 (TG) is shared between testbed33 & testbed34
1146
1147 ```
1148 - SUT [Server-Type-B9]:
1149     - testbedname: testbed34.
1150     - hostname: s27-t34-sut1.
1151     - IPMI IP: 10.30.50.69
1152     - Host IP: 10.30.51.69
1153     - portnames:
1154         - s27-t34-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1155         - s27-t34-sut1-c6/p2 - 40GE-port1 XL710-QDA2-2p40GE.
1156         - s27-t34-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1157         - s27-t34-sut1-c18/p2 - 40GE-port1 XL710-QDA2-2p40GE.
1158 - TG [Server-Type-B12]:
1159     - testbedname: testbed33 and testbed34.
1160     - hostname: s19-t33t34-tg1.
1161     - IPMI IP: 10.30.50.46
1162     - Host IP: 10.30.51.49
1163     - portnames:
1164         - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1165         - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1166         - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1167         - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1168         - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1169         - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1170         - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1171         - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
1172         - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1173         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1174         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1175         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1176 ```
1177
1178 #### 3-Node-Skylake Servers (3n-skx) PROD
1179
1180 ```
1181 - ServerB11 [Server-Type-B1]:
1182     - testbedname: testbed31.
1183     - hostname: s11-t31-sut1.
1184     - IPMI IP: 10.30.50.43
1185     - Host IP: 10.30.51.46
1186     - portnames:
1187         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1188         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1189         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1190         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1191         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1192         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1193         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1194         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1195 - ServerB12 [Server-Type-B1]:
1196     - testbedname: testbed31.
1197     - hostname: s12-t31-sut2.
1198     - IPMI IP: 10.30.50.44
1199     - Host IP: 10.30.51.47
1200     - portnames:
1201         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1202         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1203         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1204         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1205         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1206         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1207         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1208         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1209 - ServerB13 [Server-Type-B2]:
1210     - testbedname: testbed31.
1211     - hostname: s13-t31-tg1.
1212     - IPMI IP: 10.30.50.45
1213     - Host IP: 10.30.51.48
1214     - portnames:
1215         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1216         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1217         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1218         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1219         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1220         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1221         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1222         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1223 - ServerB14 [Server-Type-B1]:
1224     - testbedname: testbed32.
1225     - hostname: s14-t32-sut1.
1226     - IPMI IP: 10.30.50.55
1227     - Host IP: 10.30.51.58
1228     - portnames:
1229         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1230         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1231         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1232         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1233         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1234         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1235         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1236         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1237 - ServerB15 [Server-Type-B1]:
1238     - testbedname: testbed32.
1239     - hostname: s15-t32-sut2.
1240     - IPMI IP: 10.30.50.56
1241     - Host IP: 10.30.51.59
1242     - portnames:
1243         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1244         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1245         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1246         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1247         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1248         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1249         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1250         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1251 - ServerB16 [Server-Type-B2]:
1252     - testbedname: testbed32.
1253     - hostname: s16-t32-tg1.
1254     - IPMI IP: 10.30.50.57
1255     - Host IP: 10.30.51.60
1256     - portnames:
1257         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1258         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1259         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1260         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1261         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1262         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1263         - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1264         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1265 ```
1266
1267 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1268
1269 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1270
1271 ```
1272 - ServerB22 [Server-Type-B5]:
1273     - testbedname: testbed35.
1274     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1275     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1276     - Host IP: 10.30.51.9
1277     - portnames:
1278         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1279         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1280     - 1GB ports (tbd)
1281 - ServerB23 [Server-Type-B5]:
1282     - testbedname: testbed35.
1283     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1284     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1285     - Host IP: 10.30.51.10
1286     - portnames:
1287         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1288         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1289     - 1GB ports (tbd)
1290 - ServerB24 [Server-Type-B5]:
1291     - testbedname: testbed35.
1292     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1293     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1294     - Host IP: 10.30.51.11
1295     - portnames:
1296         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1297         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1298     - 1GB ports (tbd)
1299 ```
1300
1301 #### 3-Node-Taishan Servers (3n-tsh) PROD
1302
1303 Note: Server19 (TG) is shared between testbed33 & testbed34
1304
1305 ```
1306 - SUT [Server-Type-B3]:
1307     - testbedname: testbed33.
1308     - hostname: s17-t33-sut1.
1309     - IPMI IP: 10.30.50.36
1310     - Host IP: 10.30.51.36
1311     - portnames:
1312         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1313         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1314         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1315         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1316 - SUT [Server-Type-B3]:
1317     - testbedname: testbed33.
1318     - hostname: s18-t33-sut2.
1319     - IPMI IP: 10.30.50.37
1320     - Host IP: 10.30.51.37
1321     - portnames:
1322         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1323         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1324         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1325         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1326 - TG [Server-Type-B12]:
1327     - testbedname: testbed33 and testbed34.
1328     - hostname: s19-t33t34-tg1.
1329     - IPMI IP: 10.30.50.46
1330     - Host IP: 10.30.51.49
1331     - portnames:
1332         - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1333         - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1334         - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1335         - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1336         - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1337         - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1338         - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1339         - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
1340         - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1341         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1342         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1343         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1344 ```
1345
1346 #### 3-Node-Denverton Servers (3n-dnv) PROD
1347
1348 ```
1349 - ServerB30 [Server-Type-B10]:
1350     - testbednames: testbed35.
1351     - hostname: s30-t35-sut1.
1352     - IPMI IP: 10.30.55.12
1353     - Host IP: 10.32.8.12
1354     - portnames:
1355         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1356         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1357         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1358         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1359 - ServerB31 [Server-Type-B10]:
1360     - testbednames: testbed35.
1361     - hostname: s31-t35-sut2.
1362     - IPMI IP: 10.30.55.13
1363     - Host IP: 10.32.8.13
1364     - portnames:
1365         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1366         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1367         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1368         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1369 ```
1370
1371 ### Per Testbed Wiring
1372
1373 #### 1-Node-Skylake Wiring (1n-skx) PROD
1374
1375 ```
1376 - testbed11:
1377     - ring1 10GE-ports x710-4p10GE:
1378         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1379     - ring2 10GE-ports x710-4p10GE:
1380         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1381     - ring3 10GE-ports x710-4p10GE:
1382         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1383     - ring4 10GE-ports x710-4p10GE:
1384         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1385 - testbed12:
1386     - ring1 10GE-ports x710-4p10GE:
1387         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1388     - ring2 10GE-ports x710-4p10GE:
1389         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1390     - ring3 10GE-ports x710-4p10GE:
1391         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1392     - ring4 10GE-ports x710-4p10GE:
1393         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1394 ```
1395
1396 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1397
1398 ```
1399 - testbed36:
1400     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1401         - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1.
1402     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1403         - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2.
1404     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1405         - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1.
1406     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1407         - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2.
1408
1409 - testbed37:
1410     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1411         - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1.
1412     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1413         - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2.
1414     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1415         - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1.
1416     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1417         - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2.
1418 ```
1419
1420 #### 1-Node-Cascadelake Wiring (1n-clx) PROD
1421
1422 ```
1423 - testbed14:
1424     - ring1 10GE-ports x710-4p10GE:
1425         - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1426     - ring2 10GE-ports x710-4p10GE:
1427         - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1428     - ring3 10GE-ports x710-4p10GE:
1429         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1430     - ring4 10GE-ports x710-4p10GE:
1431         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1432 ```
1433
1434 #### 2-Node-Skylake Wiring (2n-skx) PROD
1435
1436 ```
1437 - testbed21:
1438     - ring1 10GE-ports x710-4p10GE on SUT:
1439         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1440         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1441     - ring2 10GE-ports x710-4p10GE on SUT:
1442         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1443         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1444     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1445         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1446         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1447 - testbed22:
1448     - ring1 10GE-ports x710-4p10GE on SUT:
1449         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1450         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1451     - ring2 10GE-ports x710-4p10GE on SUT:
1452         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1453         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1454     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1455         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1456         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1457 - testbed23:
1458     - ring1 10GE-ports x710-4p10GE on SUT:
1459         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1460         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1461     - ring2 10GE-ports x710-4p10GE on SUT:
1462         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1463         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1464     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1465         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1466         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1467 - testbed24:
1468     - ring1 10GE-ports x710-4p10GE on SUT:
1469         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1470         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1471     - ring2 10GE-ports x710-4p10GE on SUT:
1472         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1473         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1474     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1475         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1476         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1477 ```
1478
1479 #### 2-Node-Denverton Wiring (2n-dnv) PROD
1480
1481 ```
1482 - testbed26:
1483     - ring1 10GE-ports x553 copper port on SUT:
1484         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1485         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1486     - ring2 10GE-ports x553 fiber port on SUT:
1487         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1488         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1489 ```
1490
1491 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1492
1493 ```
1494 - testbed25:
1495     - link1 10GE-port x710-4p10GE on SUT:
1496         - t25-tg1-p1 to t25-sut1-c2/p1.
1497     - link2 10GE-port x710-4p10GE on SUT:
1498         - t25-tg1-p2 to t25-sut1-c2/p2.
1499     - link3 10GE-port x710-4p10GE on SUT:
1500         - t25-tg1-p3 to t25-sut1-c2/p3.
1501     - link4 10GE-port x710-4p10GE on SUT:
1502         - t25-tg1-p4 to t25-sut1-c2/p4.
1503 ```
1504
1505 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1506
1507 ```
1508 - testbed27:
1509     - ring1 10GE-ports x710-4p10GE on SUT:
1510         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1511         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1512     - ring2 10GE-ports x710-4p10GE on SUT:
1513         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1514         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1515     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1516         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1517         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1518     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1519         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1520         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1521     - ring5 100GE-ports e810-2p100GE on SUT:
1522         - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1523         - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1524 - testbed28:
1525     - ring1 10GE-ports x710-4p10GE on SUT:
1526         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1527         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1528     - ring2 10GE-ports x710-4p10GE on SUT:
1529         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1530         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1531     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1532         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1533         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1534     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1535         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1536         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1537     - ring5 100GE-ports e810-2p100GE on SUT:
1538         - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1539         - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1540 - testbed29:
1541     - ring1 10GE-ports x710-4p10GE on SUT:
1542         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1543         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1544     - ring2 10GE-ports x710-4p10GE on SUT:
1545         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1546         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1547     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1548         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1549         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1550     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1551         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1552         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1553     - ring6 100GE-ports e810-2p100GE on SUT:
1554         - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1555         - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1556 ```
1557
1558 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1559
1560 ```
1561 - testbed210:
1562     - ring1 10GE-ports x710-4p10GE on SUT:
1563         - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1564         - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1565     - ring2 10GE-ports x710-4p10GE on SUT:
1566         - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1567         - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1568     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1569         - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1570         - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1571     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1572         - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1573         - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1574 ```
1575
1576 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
1577
1578 ```
1579 - testbed34:
1580     - ring1 10GE-ports x520-2p10GE on SUTs:
1581         - s27-t34-sut1-c18/p1 - s19-t33t34-tg1-c8/p1.
1582         - s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2.
1583 ```
1584
1585 #### 3-Node-Skylake Wiring (3n-skx) PROD
1586
1587 ```
1588 - testbed31:
1589     - ring1 10GE-ports x710-4p10GE on SUTs:
1590         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1591         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1592         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1593     - ring2 10GE-ports x710-4p10GE on SUT:
1594         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1595         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1596         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1597     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1598         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1599         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1600         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1601     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1602         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1603         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1604         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1605     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1606         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1607         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1608 - testbed32:
1609     - ring1 10GE-ports x710-4p10GE on SUTs:
1610         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1611         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1612         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1613     - ring2 10GE-ports x710-4p10GE on SUT:
1614         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1615         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1616         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1617     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1618         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1619         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1620         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1621     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1622         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1623         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1624         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1625     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1626         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1627         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1628 ```
1629
1630 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1631
1632 ```
1633 To be completed.
1634 ```
1635
1636 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1637
1638 ```
1639 - testbed33:
1640     - ring1 10GE-ports x520-2p10GE on SUTs:
1641         - s19-t33t34-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1642         - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1643         - s18-t33-sut2-c6/p1 - s19-t33t34-tg1-c2/p1.
1644     - ring2 25GE-ports cx4-2p25GE on SUTs:
1645         - s19-t33t34-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1646         - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1647         - s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1.
1648 ```
1649
1650 #### 3-Node-Denverton Wiring (3n-dnv) PROD
1651
1652 ```
1653 - testbed35:
1654     - ring1 10GE-ports x553 copper port on SUTs:
1655         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1656         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1657         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1658     - ring2 10GE-ports x553 fiber port on SUTs:
1659         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1660         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1661         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1662 ```
1663
1664 ## Inventory
1665
1666 ### Appliances
1667
1668 ```
1669 1. Ixia PerfectStorm One Appliance
1670     - 1 * PS10GE4NG
1671         - Chassis: PS10GE4NG.
1672         - Motherboard: SuperMicro X11DPG-QT.
1673         - Processors: Quad-Core, Intel Processor.
1674         - HW accelerators: FPGA offload.
1675         - RAM Memory: 64GB.
1676         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1677         - Physical Interfaces: 4 * 10GE SFP+.
1678         - Operating System: Native IxOS.
1679 ```
1680
1681 ### Arm Servers
1682
1683 ```
1684 1. Arm Cortex A-72 servers
1685     - 2 * ThunderX2 (VPP Device)
1686         - Chassis: GIGABYTE Rack Mount
1687         - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
1688         - RAM Memory: 16* 16GB DIMM
1689         - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1690     - 1 * ThunderX2 (Performance)
1691         - Chassis: GIGABYTE Rack Mount
1692         - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
1693         - RAM Memory: 4* 32GB RDIMM
1694         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1695     - 2 * Huawei TaiShan 2280.
1696         - Chassis: Huawei TaiShan 2280.
1697         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
1698         - RAM Memory: 8* 16GB DDR4-2400MT/s.
1699         - Disks: 1* 4TB SATA HDD.
1700 ```
1701
1702 ### Xeon and Atom Servers
1703
1704 ```
1705 1. Intel Xeon servers:
1706     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1707         - Chassis: SuperMicro SYS-7049GP-TRT.
1708         - Motherboard: SuperMicro X11DPG-QT.
1709         - Processors: 2* Intel Platinum 8180 2.5 GHz.
1710         - RAM Memory: 16* 16GB DDR4-2666MHz.
1711         - Disks: 2* 1.6TB 6G SATA SSD.
1712 2. Intel Atom servers with Rangely processors.
1713     - 3 * Netgate XG-2758-1u
1714         - Chassis: Netgate XG-2758-1u
1715         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1716         - RAM Memory: 16GB ECC
1717         - Disks: 150 GB
1718 ```
1719
1720 ### Network Interface Cards
1721
1722 ```
1723 1. 10GE NICs
1724     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1725     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1726     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1727 2. 25GE NICs
1728     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1729 3. 40GE NICs
1730     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1731 4. 100GE NICs
1732     - 4 * mcx556a-edat NICs (not on site yet, in transit)
1733 ```
1734
1735 ### Pluggables and Cables
1736
1737 Pluggables:
1738
1739 ```
1740 1. 10GE SFP+
1741     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1742     - 80 * 10G SR optic (generic, "Intel" compatible branded)
1743 2. 25GE SFP28
1744     - None
1745 3. 40GE QSFP+
1746     - None
1747 4. 100GE
1748     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1749 ```
1750
1751 Standalone cables:
1752
1753 ```
1754 1. 10GE
1755     - None
1756 2. 25GE
1757     - None
1758 3. 40GE QSFP+
1759     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
1760 4. 100GE
1761     - None
1762 ```
1763
1764 ### Other Parts