Infra: Decommission 3n-hsw - pxe/ansible
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14    1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
15    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
16    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
17    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19    1. [Requirements](#requirements)
20    1. [Addressing](#addressing)
21    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24    1. [Server Types](#server-types)
25    1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29       1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
30       1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
31       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32       1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
33       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34       1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
35       1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
36       1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
37       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
38       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
39       1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
40    1. [Per Testbed Wiring](#per-testbed-wiring)
41       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42       1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
43       1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
44       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45       1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
46       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
48       1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
49       1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
50       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
51       1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
52       1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
53 1. [Inventory](#inventory)
54    1. [Appliances](#appliances)
55    1. [Arm Servers](#arm-servers)
56    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57    1. [Network Interface Cards](#network-interface-cards)
58    1. [Pluggables and Cables](#pluggables-and-cables)
59    1. [Other Parts](#other-parts)
60
61 ## Purpose
62
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
65
66 ## Testbeds Overview
67
68 ### Summary List
69
70 ```
71  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
72  1. 1-Node-Haswell     nomad  hsw   na    4    4    0    4    0    0    0    0    0    0    0    0
73  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0
74  3. 1-Node-ThunderX2   perf   tx2   na    1    1    .5   0    .5   0    0    0    1    0    0    0
75  4. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0
76  5. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    1    0
77  6. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0    0
78  7. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0
79  8. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0
80  9. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    6    0
81 10. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0
82 11. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0
83 12. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0
84 13. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0
85 14. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    2
86                                  Totals: 25   31   15    4   19    1    2    3    3    2    7    2
87 ```
88
89 ### 1-Node-Skylake Xeon Intel (1n-skx)
90
91 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
92 ports connected back-to-back ([Server Types](#server-types)).
93 Used for FD.io VPP_Device functional driver tests.
94
95 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
96
97 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC
98 ports connected back-to-back ([Server Types](#server-types)).
99 Used for FD.io VPP_Device functional driver tests.
100
101 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
102
103 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
104 NIC ports connected back-to-back ([Server Types](#server-types)).
105
106 Used for FD.io VPP_Device functional driver tests.
107
108 ### 2-Node-Skylake Xeon Intel (2n-skx)
109
110 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
111 (Server-Type-B2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
114
115 ### 2-Node-Denverton Atom Intel (2n-dnv)
116
117 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
118 TG (Server-Type-B2) connected in a 2-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
121
122 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
123
124 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
125 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
126 circular topology ([Server Types](#server-types)).
127 Used for FD.io TCP/IP and HTTP performance tests.
128
129 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
130
131 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
132 one TG (Server-Type-C3) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
135
136 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
137
138 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
139 one TG (Server-Type-D2) connected in a 2-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
142
143 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
144
145 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) and
146 one TG (Server-Type-B12) connected in a 2-node circular topology
147 ([Server Types](#server-types)).
148 Used for FD.io performance tests.
149
150 ### 3-Node-Haswell Xeon Intel (3n-hsw)
151
152 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
153 TG (Server-Type-A2) connected in a 3-node circular topology
154 ([Server Types](#server-types)).
155 Used for FD.io performance tests.
156
157 ### 3-Node-Skylake Xeon Intel (3n-skx)
158
159 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
160 TG (Server-Type-B2) connected in a 3-node circular topology.
161 Used for FD.io performance tests.
162
163 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
164
165 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
166 TG (Server-Type-B12) connected in a 3-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
169
170 ### 3-Node-Rangeley Atom Testbeds
171
172 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
173 TG (Server-Type-2) connected in a 3-node circular topology
174 ([Server Types](#server-types)).
175 Used for FD.io performance tests.
176
177 ## Server Management
178
179 ### Requirements
180
181 For management purposes, each server must have following two ports
182 connected to the management network:
183
184 ```
185 - 1GE IPMI port
186   - IPMI - Intelligent Platform Management Interface.
187   - Required for access to embedded server management with WebUI, CLI,
188     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
189 - 1GE/10GE/40GE management port
190   - hostOS management port for general system management.
191 ```
192
193 ### Addressing
194
195 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
196 Management port, which are connected to two different VLANs.
197
198 ```
199 1. LOM (IPMI) VLAN:
200     - Subnet: 10.30.50.0/24
201     - Gateway: 10.30.50.1
202     - Broadcast: 10.30.50.255
203     - DNS1: 199.204.44.24
204     - DNS2: 199.204.47.54
205 2. Management Vlan:
206     - Subnet: 10.30.51.0/24
207     - Gateway: 10.30.51.1
208     - Broadcast: 10.30.51.255
209     - DNS1: 199.204.44.24
210     - DNS2: 199.204.47.54
211 ```
212
213 To access these hosts, VPN connection is required.
214
215 ### LOM (IPMI) VLAN IP Addresses
216
217 Name         | Comment
218 ------------ | -------
219 10.30.50.0   | network
220 10.30.51.1   | Router
221 10.30.50.2   | LF Reserved
222 10.30.50.3   | LF Reserved
223 10.30.50.4   | LF Reserved
224 10.30.50.5   | LF Reserved
225 10.30.50.6   | LF Reserved
226 10.30.50.7   | LF Reserved
227 10.30.50.8   | LF Reserved
228 10.30.50.9   | LF Reserved
229 10.30.50.10  | LF Reserved
230 10.30.50.11  | LF Reserved
231 10.30.50.12  | LF Reserved
232 10.30.50.13  | LF Reserved
233 10.30.50.14  | LF Reserved
234 10.30.50.15  | LF Reserved
235 10.30.50.22  | s42-nomad
236 10.30.50.24  | s43-nomad
237 10.30.50.25  | s44-nomad
238 10.30.50.26  | s45-nomad
239 10.30.50.28  | s41-nomad
240 10.30.50.29  | s39-nomad
241 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
242 10.30.50.30  | s40-nomad
243 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
244 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
245 10.30.50.36  | s17-t33-sut1
246 10.30.50.37  | s18-t33-sut2
247 10.30.50.38  | fdio-marvell-dev
248 10.30.50.39  | s53-nomad
249 10.30.50.40  | s54-nomad
250 10.30.50.41  | s3-t21-sut1
251 10.30.50.42  | s4-t21-tg1
252 10.30.50.43  | s11-t31-sut1
253 10.30.50.44  | s12-t31-sut2
254 10.30.50.45  | s13-t31-tg1
255 10.30.50.46  | s19-t33t34-tg1
256 10.30.50.47  | s1-t11-sut1
257 10.30.50.48  | s2-t12-sut1
258 10.30.50.49  | s5-t22-sut1
259 10.30.50.50  | s6-t22-tg1
260 10.30.50.51  | s7-t23-sut1
261 10.30.50.52  | s8-t23-tg1
262 10.30.50.53  | s9-t24-sut1
263 10.30.50.54  | s10-t24-tg1
264 10.30.50.55  | s14-t32-sut1
265 10.30.50.56  | s15-t32-sut2
266 10.30.50.57  | s16-t32-tg1
267 10.30.50.58  | s25-t25-sut1
268 10.30.50.59  | s26-t25-tg1
269 10.30.50.65  | s52-nomad
270 10.30.50.66  | s51-nomad
271 10.30.50.67  | s49-nomad
272 10.30.50.68  | s50-nomad
273 10.30.50.69  | s27-t34-sut1
274 10.30.50.70  | s55-t36-sut1
275 10.30.50.71  | s56-t37-sut1
276 10.30.50.255 | Broadcast
277 n/a          | s20-t34-sut1
278 n/a          | s21-t34-sut2
279 10.30.55.0   | network
280 10.30.55.1   | Router
281 10.30.55.10  | s28-t26t35-tg1
282 10.30.55.11  | s29-t26-sut1
283 10.30.55.12  | s30-t35-sut1
284 10.30.55.13  | s31-t35-sut2
285 10.30.55.14  | s46-nomad
286 10.30.55.15  | s47-nomad
287 10.30.55.16  | s48-nomad
288 10.30.55.17  | s57-nomad
289 10.30.55.18  | s33-t27-sut1
290 10.30.55.19  | s34-t27-tg1
291 10.30.55.20  | s35-t28-sut1
292 10.30.55.21  | s36-t28-tg1
293 10.30.55.22  | s37-t29-sut1
294 10.30.55.23  | s38-t29-tg1
295 10.30.55.24  | s60-t210-sut1
296 10.30.55.25  | s61-t210-tg1
297 10.30.55.255 | Broadcast
298
299 ### Management VLAN IP Addresses
300
301 Name                      | Comment
302 ------------------------- | -------
303 10.30.51.0                | network
304 10.30.51.1                | Router
305 10.30.51.2                | LF Reserved
306 10.30.51.3                | LF Reserved
307 10.30.51.4                | LF Reserved
308 10.30.51.5                | LF Reserved
309 10.30.51.6                | LF Reserved
310 10.30.51.7                | LF Reserved
311 10.30.51.8                | LF Reserved
312 10.30.51.15               | LF Reserved
313 10.30.51.22               | s42-nomad
314 10.30.51.24               | s43-nomad
315 10.30.51.25               | s44-nomad
316 10.30.51.26               | s45-nomad
317 10.30.51.28               | s41-nomad
318 10.30.51.29               | s39-nomad
319 10.30.51.30               | s40-nomad
320 10.30.51.36               | s17-t33-sut1
321 10.30.51.37               | s18-t33-sut2
322 10.30.51.38               | fdio-marvell-dev
323 10.30.51.39               | s53-nomad
324 10.30.51.40               | s54-nomad
325 10.30.51.44               | s3-t21-sut1
326 10.30.51.45               | s4-t21-tg1
327 10.30.51.46               | s11-t31-sut1
328 10.30.51.47               | s12-t31-sut2
329 10.30.51.48               | s13-t31-tg1
330 10.30.51.49               | s19-t33t34-tg1
331 10.30.51.50               | s1-t11-sut1
332 10.30.51.51               | s2-t12-sut1
333 10.30.51.52               | s5-t22-sut1
334 10.30.51.53               | s6-t22-tg1
335 10.30.51.54               | s7-t23-sut1
336 10.30.51.55               | s8-t23-tg1
337 10.30.51.56               | s9-t24-sut1
338 10.30.51.57               | s10-t24-tg1
339 10.30.51.58               | s14-t32-sut1
340 10.30.51.59               | s15-t32-sut2
341 10.30.51.60               | s16-t32-tg1
342 10.30.51.61               | s25-t25-sut1
343 10.30.51.62               | s26-t25-tg1
344 10.30.51.65               | s52-nomad
345 10.30.51.66               | s51-nomad
346 10.30.51.67               | s49-nomad
347 10.30.51.68               | s50-nomad
348 10.30.51.69               | s27-t34-sut1
349 10.30.51.70               | s55-t36-sut1
350 10.30.51.71               | s56-t37-sut1
351 10.30.51.72-10.30.51.254  | FREE
352 10.30.51.255              | Broadcast
353 10.32.8.0                 | network
354 10.32.8.1                 | Router
355 10.32.8.10                | s28-t26t35-tg1
356 10.32.8.11                | s29-t26-sut1
357 10.32.8.12                | s30-t35-sut1
358 10.32.8.13                | s31-t35-sut2
359 10.32.8.14                | s46-nomad
360 10.32.8.15                | s47-nomad
361 10.32.8.16                | s48-nomad
362 10.32.8.17                | s57-nomad
363 10.32.8.18                | s33-t27-sut1
364 10.32.8.19                | s34-t27-tg1
365 10.32.8.20                | s35-t28-sut1
366 10.32.8.21                | s36-t28-tg1
367 10.32.8.22                | s37-t29-sut1
368 10.32.8.23                | s38-t29-tg1
369 10.32.8.24                | s60-t210-sut1
370 10.32.8.25                | s61-t210-tg1
371 10.32.8.255               | Broadcast
372
373 ## Server Specifications
374
375 ### Server Types
376
377 FD.io CSIT lab contains following server types:
378 ```
379 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
380     - Quantity: 6 servers.
381     - Physical connectivity:
382         - CIMC and host management ports.
383         - NIC ports connected in 3-node topologies.
384     - Main HW configuration:
385         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
386         - Processors: 2* E5-2699v3 2.3 GHz.
387         - RAM Memory: 16* 32GB DDR4-2133MHz.
388         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
389     - NICs configuration:
390         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
391             - PCIe Slot1: empty.
392             - PCIe Slot2: empty.
393             - PCIe Slot3: empty.
394         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
395             - PCIe Slot4: empty.
396             - PCIe Slot5: empty.
397             - PCIe Slot6: empty
398         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
399 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
400     - Quantity: 3 servers.
401     - Physical connectivity:
402         - CIMC and host management ports.
403         - NIC ports connected in 3-node topologies.
404     - Main HW configuration:
405         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
406         - Processors: 2* E5-2699v3 2.3 GHz.
407         - RAM Memory: 16* 32GB DDR4-2133MHz.
408         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
409     - NICs configuration:
410         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
411             - PCIe Slot1: empty.
412             - PCIe Slot2: empty.
413             - PCIe Slot3: empty.
414         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
415             - PCIe Slot4: empty.
416             - PCIe Slot5: empty.
417             - PCIe Slot6: empty
418         - MLOM slot: empty.
419 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
420     - Quantity: 3 servers.
421     - Physical connectivity:
422         - CIMC and host management ports.
423         - no NIC ports, standalone setup.
424     - Main HW configuration:
425         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
426         - Processors: 2* E5-2699v3 2.3 GHz.
427         - RAM Memory: 16* 32GB DDR4-2133MHz.
428         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
429     - NICs configuration:
430         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
431             - no cards.
432         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
433             - no cards.
434         - MLOM slot: empty.
435 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
436     - Quantity: ---
437     - Physical connectivity:
438         - IPMI and host management ports.
439         - NIC ports connected into 2-node and 3-node topologies.
440     - Main HW configuration:
441         - Chassis: SuperMicro SYS-7049GP-TRT.
442         - Motherboard: SuperMicro X11DPG-QT.
443         - Processors: 2* Intel Platinum 8180 2.5 GHz.
444         - RAM Memory: 16* 16GB DDR4-2666MHz.
445         - Disks: 2* 1.6TB 6G SATA SSD.
446     - NICs configuration:
447         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
448             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
449             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
450             - PCIe Slot9 5e:00.xx: empty.
451         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
452             - PCIe Slot6 86:00.xx: empty.
453             - PCIe Slot8 af:00.xx: empty.
454             - PCIe Slot10 d8:00.xx: empty.
455 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
456     - Quantity: ---
457     - Physical connectivity:
458         - IPMI and host management ports.
459         - NIC ports connected into 2-node and 3-node topologies.
460     - Main HW configuration:
461         - Chassis: SuperMicro SYS-7049GP-TRT.
462         - Motherboard: SuperMicro X11DPG-QT.
463         - Processors: 2* Intel Platinum 8180 2.5 GHz.
464         - RAM Memory: 16* 16GB DDR4-2666MHz.
465         - Disks: 2* 1.6TB 6G SATA SSD.
466     - NICs configuration:
467         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
468             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
469             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
470             - PCIe Slot9 5e:00.xx: empty.
471         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
472             - PCIe Slot6 86:00.xx: empty.
473             - PCIe Slot8 af:00.xx: empty.
474             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
475 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
476     - Quantity: 2
477     - Physical connectivity:
478         - IPMI(?) and host management ports.
479         - NIC ports connected into 3-node topology.
480     - Main HW configuration:
481         - Chassis: Huawei TaiShan 2280.
482         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
483         - RAM Memory: 8* 16GB DDR4-2400MT/s
484         - Disks: 1* 4TB SATA HDD
485     - NICs configuration:
486         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
487         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
488 7. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
489     - Quantity: TBD based on testbed allocation.
490     - Physical connectivity:
491         - Management: serial Port (usb) for console
492         - NIC ports connected into 2-node.
493     - Main HW configuration:
494         - Chassis: Netgate XG-2758-1u
495         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
496         - RAM Memory: 16GB ECC
497         - Disks: 150 GB
498     - NICs configuration:
499         - 2x 10Gb Intel 82599ES
500         - 4x 1GB Intel I354
501 8. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
502     - Quantity: 2.
503     - Physical connectivity:
504         - IPMI and host management ports.
505         - NIC ports connected into 1-node topologies.
506     - Main HW configuration:
507         - Chassis: SuperMicro SYS-7049GP-TRT.
508         - Motherboard: SuperMicro X11DPG-QT.
509         - Processors: 2* Intel Platinum 8180 2.5 GHz.
510         - RAM Memory: 16* 16GB DDR4-2666MHz.
511         - Disks: 2* 1.6TB 6G SATA SSD.
512     - NICs configuration:
513         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
514             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
515             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
516             - PCIe Slot9 5e:00.xx: empty.
517         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
518             - PCIe Slot6 86:00.xx: empty.
519             - PCIe Slot8 af:00.xx: empty.
520             - PCIe Slot10 d8:00.xx: empty.
521 9. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
522     - Quantity: 1.
523     - Physical connectivity:
524         - Host management interface: 10/100/1000-BaseT.
525         - 8-port 10GE SFP+ integrated NIC.
526     - Main HW configuration:
527         - Chassis: PS10GE4NG.
528         - Motherboard: SuperMicro X11DPG-QT.
529         - Processors: Quad-Core, Intel Processor.
530         - HW accelerators: FPGA offload.
531         - RAM Memory: 64GB.
532         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
533         - Physical Interfaces: 4 * 10GE SFP+.
534         - Operating System: Native IxOS.
535     - Interface configuration:
536         - Port-1: 10GE SFP+.
537         - Port-2: 10GE SFP+.
538         - Port-3: 10GE SFP+.
539         - Port-4: 10GE SFP+.
540 10. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
541     - Quantity: 1.
542     - Physical connectivity:
543         - IPMI and host management ports.
544         - NIC ports.
545     - Main HW configuration:
546         - Chassis: SuperMicro SYS-7049GP-TRT.
547         - Motherboard: SuperMicro X11DPG-QT.
548         - Processors: 2* Intel Platinum 8180 2.5 GHz.
549         - RAM Memory: 16* 16GB DDR4-2666MHz.
550         - Disks: 2* 1.6TB 6G SATA SSD.
551     - NICs configuration:
552         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
553             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
554             - PCIe Slot4 3b:00.xx: empty.
555             - PCIe Slot9 5e:00.xx: empty.
556         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
557             - PCIe Slot6 86:00.xx: empty.
558             - PCIe Slot8 af:00.xx: empty.
559             - PCIe Slot10 d8:00.xx: empty.
560 11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
561     - Quantity: 1
562     - Physical connectivity:
563         - IPMI and host management ports.
564         - NIC ports connected into 1-node topologies.
565     - Main HW configuration:
566         - Chassis: Gigabyte R181-T90 1U
567         - Motherboard: MT91-FS1
568         - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
569         - RAM Memory: 4* 32GB RDIMM
570         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
571     - NICs configuration:
572         - Numa0:
573             - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
574         - Numa1:
575             - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
576 12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
577     - Quantity: 4
578     - Physical connectivity:
579         - IPMI and host management ports.
580         - NIC ports.
581     - Main HW configuration:
582         - Chassis: SuperMicro SYS-E300-9A
583         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
584         - RAM Memory: 32GB ECC
585         - Disks: 480 GB
586     - NICs configuration:
587         - 2x 10Gb Intel x553 fiber ports
588         - 2x 10Gb Intel x553 copper ports
589         - 4x 1GB Intel I350 ports
590 13. Server-Type-B11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
591     - Quantity: 2
592     - Physical connectivity:
593         - IPMI and host management ports.
594         - NIC ports connected into 1-node topologies.
595     - Main HW configuration:
596         - Chassis: GIGABYTE Rack Mount
597         - Motherboard: MT91-FS4-00
598         - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
599         - RAM Memory: 16 * 16GB DIMM
600         - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
601     - NICs configuration:
602         - Numa0:
603             - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
604             - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
605         - Numa1:
606             - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
607             - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
608 14. Server-Type-B12: Purpose - Skylake Xeon TG for FD.io performance testing.
609     - Quantity: ---
610     - Physical connectivity:
611         - IPMI and host management ports.
612         - NIC ports connected into 2-node and 3-node topologies.
613     - Main HW configuration:
614         - Chassis: SuperMicro SYS-7049GP-TRT.
615         - Motherboard: SuperMicro X11DPG-QT.
616         - Processors: 2* Intel Platinum 8180 2.5 GHz.
617         - RAM Memory: 16* 16GB DDR4-2666MHz.
618         - Disks: 2* 1.6TB 6G SATA SSD.
619     - NICs configuration:
620         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
621             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
622             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
623             - PCIe Slot9 5e:00.xx: empty.
624         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
625             - PCIe Slot6 86:00.xx: empty.
626             - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
627             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
628
629 15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
630     - Quantity: 1.
631     - Physical connectivity:
632         - IPMI and host management ports.
633         - NIC ports connected into 1-node testbed topologies.
634     - Main HW configuration:
635         - Chassis: SuperMicro SYS-7049GP-TRT.
636         - Motherboard: SuperMicro X11DPG-QT.
637         - Processors: 2* Intel Platinum 8280 2.7 GHz.
638         - RAM Memory: 12* 16GB DDR4-2933.
639         - Disks: 2* 1.92TB SATA SSD.
640     - NICs configuration:
641         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
642             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
643             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
644             - PCIe Slot9 5e:00.xx: empty.
645         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
646             - PCIe Slot6 86:00.xx: empty.
647             - PCIe Slot8 af:00.xx: empty.
648             - PCIe Slot10 d8:00.xx: empty.
649 16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
650     - Quantity: 3
651     - Physical connectivity:
652         - IPMI and host management ports.
653         - NIC ports connected into 2-node testbed topologies.
654     - Main HW configuration:
655         - Chassis: SuperMicro SYS-7049GP-TRT.
656         - Motherboard: SuperMicro X11DPG-QT.
657         - Processors: 2* Intel Gold 6252N 2.3 GHz.
658         - RAM Memory: 12* 16GB DDR4-2933.
659         - Disks: 2* 1.92TB SATA SSD.
660     - NICs configuration:
661         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
662             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
663             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
664             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
665         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
666             - PCIe Slot6 86:00.xx: empty.
667             - PCIe Slot8 af:00.xx: empty.
668             - PCIe Slot10 d8:00.xx: empty.
669 17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
670     - Quantity: 3.
671     - Physical connectivity:
672         - IPMI and host management ports.
673         - NIC ports connected into 2-node testbed topologies.
674     - Main HW configuration:
675         - Chassis: SuperMicro SYS-7049GP-TRT.
676         - Motherboard: SuperMicro X11DPG-QT.
677         - Processors: 2* Intel Platinum 8280 2.7 GHz.
678         - RAM Memory: 12* 16GB DDR4-2933.
679         - Disks: 2* 1.92TB SATA SSD.
680     - NICs configuration:
681         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
682             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
683             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
684             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
685         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
686             - PCIe Slot6 86:00.xx: empty.
687             - PCIe Slot8 af:00.xx: empty.
688             - PCIe Slot10 d8:00.xx: empty.
689 18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
690     - Quantity: 3.
691     - Physical connectivity:
692         - CIMC and host management ports.
693         - no NIC ports, standalone setup.
694     - Main HW configuration:
695         - Chassis: SuperMicro 1029P-WTRT.
696         - Motherboard: SuperMicro X11DDW-NT.
697         - Processors: 2* Intel Platinum 8280 2.7 GHz.
698         - RAM Memory: 12* 16GB DDR4-2933.
699         - Disks: 4* 1.92TB SATA SSD.
700     - NICs configuration:
701         - Numa0:
702             - no cards.
703         - Numa1:
704             - no cards.
705 19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
706     - Quantity: 1.
707     - Physical connectivity:
708         - IPMI and host management ports.
709         - NIC ports connected into 2-node testbed topologies.
710     - Main HW configuration:
711         - Chassis: SuperMicro AS-1114S-WTRT
712         - Processors: 1* AMD EPYC 7532 2.4 GHz.
713         - RAM Memory: 8* 32GB DDR4-2933.
714         - Disks: 1* 1TB SATA SSD.
715     - NICs configuration:
716         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
717             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
718             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
719             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
720 20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
721     - Quantity: 1.
722     - Physical connectivity:
723         - IPMI and host management ports.
724         - NIC ports connected into 2-node testbed topologies.
725     - Main HW configuration:
726         - Chassis: SuperMicro AS-1114S-WTRT
727         - Processors: 1* AMD EPYC 7532 2.4 GHz.
728         - RAM Memory: 8* 32GB DDR4-2933.
729         - Disks: 1* 1TB SATA SSD.
730     - NICs configuration:
731         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
732             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
733             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
734             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
735 ```
736
737 ### Naming Convention
738
739 Following naming convention is used within this page to specify physical
740 connectivity and wiring across defined CSIT testbeds:
741
742 ```
743 - testbedname: testbedN.
744 - hostname:
745     - traffic-generator: tN-tgW.
746     - system-under-testX: tN-sutX.
747 - portnames:
748     - tN-tgW-cY/pZ.
749     - tN-sutX-cY/pZ.
750 - where:
751     - N - testbed number.
752     - tgW - server acts as traffic-generator with W index.
753     - sutX - server acts as system-under-test with X index.
754     - Y - PCIe slot number denoting a NIC card number within the host.
755     - Z - port number on the NIC card.
756 ```
757
758 ## Testbeds Configuration
759
760 ### Per Testbed Server Allocation and Naming
761
762 #### 1-Node-Skylake Servers (1n-skx) PROD
763
764 ```
765 - SUT [Server-Type-B6]:
766     - testbedname: testbed11.
767     - hostname: s1-t11-sut1.
768     - IPMI IP: 10.30.50.47
769     - Host IP: 10.30.51.50
770     - portnames:
771         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
772         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
773         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
774         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
775         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
776         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
777         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
778         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
779 - SUT [Server-Type-B6]:
780     - testbedname: testbed12.
781     - hostname: s2-t12-sut1.
782     - IPMI IP: 10.30.50.48
783     - Host IP: 10.30.51.51
784     - portnames:
785         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
786         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
787         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
788         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
789         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
790         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
791         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
792         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
793 ```
794
795 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
796
797 ```
798 - SUT [Server-Type-B11]:
799     - testbedname: testbed36
800     - hostname: s55-t36-sut1
801     - IPMI IP: 10.30.50.70
802     - Host IP: 10.30.51.70
803     - portnames:
804         - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
805         - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
806         - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
807         - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
808         - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
809         - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
810         - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
811         - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
812 - SUT [Server-Type-B11]:
813     - testbedname: testbed37
814     - hostname: s56-t37-sut1
815     - IPMI IP: 10.30.50.71
816     - Host IP: 10.30.51.71
817     - portnames:
818         - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
819         - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
820         - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
821         - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
822         - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
823         - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
824         - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
825         - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
826 ```
827
828 #### 1-Node-Cascadelake Servers (1n-clx) PROD
829
830 ```
831 - SUT [Server-Type-C1]:
832     - testbedname: testbed11.
833     - hostname: s32-t14-sut1.
834     - IPMI IP: 10.30.55.17
835     - Host IP: 10.32.8.17
836     - portnames:
837         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
838         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
839         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
840         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
841         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
842         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
843         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
844         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
845 ```
846
847 #### 2-Node-Skylake Servers (2n-skx) PROD
848
849 ```
850 - SUT [Server-Type-B1]:
851     - testbedname: testbed21.
852     - hostname: s3-t21-sut1.
853     - IPMI IP: 10.30.50.41
854     - Host IP: 10.30.51.44
855     - portnames:
856         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
857         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
858         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
859         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
860         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
861         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
862 - TG [Server-Type-B2]:
863     - testbedname: testbed21.
864     - hostname: s4-t21-tg1.
865     - IPMI IP: 10.30.50.42
866     - Host IP: 10.30.51.45
867     - portnames:
868         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
869         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
870         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
871         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
872         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
873         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
874 - SUT [Server-Type-B1]:
875     - testbedname: testbed22.
876     - hostname: s5-t22-sut1.
877     - IPMI IP: 10.30.50.49
878     - Host IP: 10.30.51.52
879     - portnames:
880         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
881         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
882         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
883         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
884         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
885         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
886 - TG [Server-Type-B2]:
887     - testbedname: testbed22.
888     - hostname: s6-t22-tg1.
889     - IPMI IP: 10.30.50.50
890     - Host IP: 10.30.51.53
891     - portnames:
892         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
893         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
894         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
895         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
896         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
897         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
898 - SUT [Server-Type-B1]:
899     - testbedname: testbed23.
900     - hostname: s7-t23-sut1.
901     - IPMI IP: 10.30.50.51
902     - Host IP: 10.30.51.54
903     - portnames:
904         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
905         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
906         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
907         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
908         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
909         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
910 - TG [Server-Type-B2]:
911     - testbedname: testbed23.
912     - hostname: s8-t23-tg1.
913     - IPMI IP: 10.30.50.52
914     - Host IP: 10.30.51.55
915     - portnames:
916         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
917         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
918         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
919         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
920         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
921         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
922 - SUT [Server-Type-B1]:
923     - testbedname: testbed24.
924     - hostname: s9-t24-sut1.
925     - IPMI IP: 10.30.50.53
926     - Host IP: 10.30.51.56
927     - portnames:
928         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
929         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
930         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
931         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
932         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
933         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
934 - TG [Server-Type-B2]:
935     - testbedname: testbed24.
936     - hostname: s10-t24-tg1.
937     - IPMI IP: 10.30.50.54
938     - Host IP: 10.30.51.57
939     - portnames:
940         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
941         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
942         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
943         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
944         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
945         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
946 ```
947
948 #### 2-Node-Denverton Servers (2n-dnv) PROD
949
950 Note: ServerB28 (TG) is shared between testbed26 & testbed35
951
952 ```
953 - TG [Server-Type-B2]:
954     - testbednames: testbed26 and testbed35.
955     - hostname: s28-t26t35-tg1.
956     - IPMI IP: 10.30.55.10
957     - Host IP: 10.32.8.10
958     - portnames:
959         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
960         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
961         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
962         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
963         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
964         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
965         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
966         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
967         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
968         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
969         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
970         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
971 - SUT [Server-Type-B10]:
972     - testbednames: testbed26.
973     - hostname: s29-t26-sut1.
974     - IPMI IP: 10.30.55.11
975     - Host IP: 10.32.8.11
976     - portnames:
977         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
978         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
979         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
980         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
981 ```
982
983 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
984
985 ```
986 - SUT [Server-Type-B8]:
987     - testbedname: testbed25.
988     - hostname: s25-t25-sut1.
989     - IPMI IP: 10.30.50.58
990     - Host IP: 10.30.51.61
991     - portnames:
992         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
993         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
994         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
995         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
996 - TG [Server-Type-B7]:
997     - testbedname: testbed25.
998     - hostname: s26-t25-tg1.
999     - IPMI IP: 10.30.50.59
1000     - Host IP: 10.30.51.62
1001     - portnames:
1002         - s26-t25-tg1-p1 - 10GE-port1.
1003         - s26-t25-tg1-p2 - 10GE-port2.
1004         - s26-t25-tg1-p3 - 10GE-port3.
1005         - s26-t25-tg1-p4 - 10GE-port4.
1006 ```
1007
1008 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1009
1010 ```
1011 - SUT [Server-Type-C2]:
1012     - testbedname: testbed27.
1013     - hostname: s33-t27-sut1.
1014     - IPMI IP: 10.30.55.18
1015     - Host IP: 10.32.8.18
1016     - portnames:
1017         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1018         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1019         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1020         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1021         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1022         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1023         - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1024         - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1025         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1026         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1027 - TG [Server-Type-C3]:
1028     - testbedname: testbed27.
1029     - hostname: s34-t27-tg1.
1030     - IPMI IP: 10.30.55.19
1031     - Host IP: 10.32.8.19
1032     - portnames:
1033         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1034         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1035         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1036         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1037         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1038         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1039         - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1040         - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1041         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1042         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1043 - SUT [Server-Type-C2]:
1044     - testbedname: testbed28.
1045     - hostname: s35-t28-sut1.
1046     - IPMI IP: 10.30.55.20
1047     - Host IP: 10.32.8.20
1048     - portnames:
1049         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1050         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1051         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1052         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1053         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1054         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1055         - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1056         - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1057         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1058         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1059 - TG [Server-Type-C3]:
1060     - testbedname: testbed28.
1061     - hostname: s36-t28-tg1.
1062     - IPMI IP: 10.30.55.21
1063     - Host IP: 10.32.8.21
1064     - portnames:
1065         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1066         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1067         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1068         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1069         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1070         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1071         - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1072         - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1073         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1074         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1075 - SUT [Server-Type-C2]:
1076     - testbedname: testbed29.
1077     - hostname: s37-t29-sut1.
1078     - IPMI IP: 10.30.55.22
1079     - Host IP: 10.32.8.22
1080     - portnames:
1081         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1082         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1083         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1084         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1085         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1086         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1087         - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1088         - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1089         - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1090         - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1091 - TG [Server-Type-C3]:
1092     - testbedname: testbed29.
1093     - hostname: s38-t29-tg1.
1094     - IPMI IP: 10.30.55.23
1095     - Host IP: 10.32.8.23
1096     - portnames:
1097         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1098         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1099         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1100         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1101         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1102         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1103         - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1104         - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1105         - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1106         - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1107 ```
1108
1109 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1110
1111 ```
1112 - SUT [Server-Type-D1]:
1113     - testbedname: testbed210.
1114     - hostname: s60-t210-sut1.
1115     - IPMI IP: 10.30.55.24
1116     - Host IP: 10.32.8.24
1117     - portnames:
1118         - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1119         - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1120         - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1121         - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1122         - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1123         - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1124         - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1125         - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1126 - TG [Server-Type-D2]:
1127     - testbedname: testbed210.
1128     - hostname: s61-t210-tg1.
1129     - IPMI IP: 10.30.55.25
1130     - Host IP: 10.32.8.25
1131     - portnames:
1132         - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1133         - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1134         - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1135         - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1136         - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1137         - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1138         - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1139         - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1140 ```
1141
1142 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1143
1144 Note: Server19 (TG) is shared between testbed33 & testbed34
1145
1146 ```
1147 - SUT [Server-Type-B9]:
1148     - testbedname: testbed34.
1149     - hostname: s27-t34-sut1.
1150     - IPMI IP: 10.30.50.69
1151     - Host IP: 10.30.51.69
1152     - portnames:
1153         - s27-t34-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1154         - s27-t34-sut1-c6/p2 - 40GE-port1 XL710-QDA2-2p40GE.
1155         - s27-t34-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1156         - s27-t34-sut1-c18/p2 - 40GE-port1 XL710-QDA2-2p40GE.
1157 - TG [Server-Type-B12]:
1158     - testbedname: testbed33 and testbed34.
1159     - hostname: s19-t33t34-tg1.
1160     - IPMI IP: 10.30.50.46
1161     - Host IP: 10.30.51.49
1162     - portnames:
1163         - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1164         - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1165         - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1166         - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1167         - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1168         - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1169         - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1170         - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
1171         - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1172         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1173         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1174         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1175 ```
1176
1177 #### 3-Node-Skylake Servers (3n-skx) PROD
1178
1179 ```
1180 - ServerB11 [Server-Type-B1]:
1181     - testbedname: testbed31.
1182     - hostname: s11-t31-sut1.
1183     - IPMI IP: 10.30.50.43
1184     - Host IP: 10.30.51.46
1185     - portnames:
1186         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1187         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1188         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1189         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1190         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1191         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1192         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1193         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1194 - ServerB12 [Server-Type-B1]:
1195     - testbedname: testbed31.
1196     - hostname: s12-t31-sut2.
1197     - IPMI IP: 10.30.50.44
1198     - Host IP: 10.30.51.47
1199     - portnames:
1200         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1201         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1202         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1203         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1204         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1205         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1206         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1207         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1208 - ServerB13 [Server-Type-B2]:
1209     - testbedname: testbed31.
1210     - hostname: s13-t31-tg1.
1211     - IPMI IP: 10.30.50.45
1212     - Host IP: 10.30.51.48
1213     - portnames:
1214         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1215         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1216         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1217         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1218         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1219         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1220         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1221         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1222 - ServerB14 [Server-Type-B1]:
1223     - testbedname: testbed32.
1224     - hostname: s14-t32-sut1.
1225     - IPMI IP: 10.30.50.55
1226     - Host IP: 10.30.51.58
1227     - portnames:
1228         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1229         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1230         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1231         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1232         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1233         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1234         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1235         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1236 - ServerB15 [Server-Type-B1]:
1237     - testbedname: testbed32.
1238     - hostname: s15-t32-sut2.
1239     - IPMI IP: 10.30.50.56
1240     - Host IP: 10.30.51.59
1241     - portnames:
1242         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1243         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1244         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1245         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1246         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1247         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1248         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1249         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1250 - ServerB16 [Server-Type-B2]:
1251     - testbedname: testbed32.
1252     - hostname: s16-t32-tg1.
1253     - IPMI IP: 10.30.50.57
1254     - Host IP: 10.30.51.60
1255     - portnames:
1256         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1257         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1258         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1259         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1260         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1261         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1262         - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1263         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1264 ```
1265
1266 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1267
1268 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1269
1270 ```
1271 - ServerB22 [Server-Type-B5]:
1272     - testbedname: testbed35.
1273     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1274     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1275     - Host IP: 10.30.51.9
1276     - portnames:
1277         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1278         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1279     - 1GB ports (tbd)
1280 - ServerB23 [Server-Type-B5]:
1281     - testbedname: testbed35.
1282     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1283     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1284     - Host IP: 10.30.51.10
1285     - portnames:
1286         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1287         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1288     - 1GB ports (tbd)
1289 - ServerB24 [Server-Type-B5]:
1290     - testbedname: testbed35.
1291     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1292     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1293     - Host IP: 10.30.51.11
1294     - portnames:
1295         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1296         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1297     - 1GB ports (tbd)
1298 ```
1299
1300 #### 3-Node-Taishan Servers (3n-tsh) PROD
1301
1302 Note: Server19 (TG) is shared between testbed33 & testbed34
1303
1304 ```
1305 - SUT [Server-Type-B3]:
1306     - testbedname: testbed33.
1307     - hostname: s17-t33-sut1.
1308     - IPMI IP: 10.30.50.36
1309     - Host IP: 10.30.51.36
1310     - portnames:
1311         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1312         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1313         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1314         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1315 - SUT [Server-Type-B3]:
1316     - testbedname: testbed33.
1317     - hostname: s18-t33-sut2.
1318     - IPMI IP: 10.30.50.37
1319     - Host IP: 10.30.51.37
1320     - portnames:
1321         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1322         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1323         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1324         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1325 - TG [Server-Type-B12]:
1326     - testbedname: testbed33 and testbed34.
1327     - hostname: s19-t33t34-tg1.
1328     - IPMI IP: 10.30.50.46
1329     - Host IP: 10.30.51.49
1330     - portnames:
1331         - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1332         - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1333         - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1334         - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1335         - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1336         - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1337         - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1338         - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
1339         - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1340         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1341         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1342         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1343 ```
1344
1345 #### 3-Node-Denverton Servers (3n-dnv) PROD
1346
1347 ```
1348 - ServerB30 [Server-Type-B10]:
1349     - testbednames: testbed35.
1350     - hostname: s30-t35-sut1.
1351     - IPMI IP: 10.30.55.12
1352     - Host IP: 10.32.8.12
1353     - portnames:
1354         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1355         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1356         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1357         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1358 - ServerB31 [Server-Type-B10]:
1359     - testbednames: testbed35.
1360     - hostname: s31-t35-sut2.
1361     - IPMI IP: 10.30.55.13
1362     - Host IP: 10.32.8.13
1363     - portnames:
1364         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1365         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1366         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1367         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1368 ```
1369
1370 ### Per Testbed Wiring
1371
1372 #### 1-Node-Skylake Wiring (1n-skx) PROD
1373
1374 ```
1375 - testbed11:
1376     - ring1 10GE-ports x710-4p10GE:
1377         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1378     - ring2 10GE-ports x710-4p10GE:
1379         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1380     - ring3 10GE-ports x710-4p10GE:
1381         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1382     - ring4 10GE-ports x710-4p10GE:
1383         - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1384     - ring5 100GE-ports e810-2p100GE:
1385         - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1386     - ring6 100GE-ports e810-2p100GE:
1387         - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1388 - testbed12:
1389     - ring1 10GE-ports x710-4p10GE:
1390         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1391     - ring2 10GE-ports x710-4p10GE:
1392         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1393     - ring3 10GE-ports x710-4p10GE:
1394         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1395     - ring4 10GE-ports x710-4p10GE:
1396         - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1397     - ring5 100GE-ports e810-2p100GE:
1398         - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1399     - ring6 100GE-ports e810-2p100GE:
1400         - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1401 ```
1402
1403 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1404
1405 ```
1406 - testbed36:
1407     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1408         - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1.
1409     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1410         - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2.
1411     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1412         - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1.
1413     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1414         - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2.
1415
1416 - testbed37:
1417     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1418         - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1.
1419     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1420         - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2.
1421     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1422         - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1.
1423     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1424         - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2.
1425 ```
1426
1427 #### 1-Node-Cascadelake Wiring (1n-clx) PROD
1428
1429 ```
1430 - testbed14:
1431     - ring1 10GE-ports x710-4p10GE:
1432         - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1433     - ring2 10GE-ports x710-4p10GE:
1434         - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1435     - ring3 10GE-ports x710-4p10GE:
1436         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1437     - ring4 10GE-ports x710-4p10GE:
1438         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1439 ```
1440
1441 #### 2-Node-Skylake Wiring (2n-skx) PROD
1442
1443 ```
1444 - testbed21:
1445     - ring1 10GE-ports x710-4p10GE on SUT:
1446         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1447         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1448     - ring2 10GE-ports x710-4p10GE on SUT:
1449         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1450         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1451     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1452         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1453         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1454 - testbed22:
1455     - ring1 10GE-ports x710-4p10GE on SUT:
1456         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1457         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1458     - ring2 10GE-ports x710-4p10GE on SUT:
1459         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1460         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1461     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1462         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1463         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1464 - testbed23:
1465     - ring1 10GE-ports x710-4p10GE on SUT:
1466         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1467         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1468     - ring2 10GE-ports x710-4p10GE on SUT:
1469         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1470         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1471     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1472         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1473         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1474 - testbed24:
1475     - ring1 10GE-ports x710-4p10GE on SUT:
1476         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1477         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1478     - ring2 10GE-ports x710-4p10GE on SUT:
1479         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1480         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1481     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1482         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1483         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1484 ```
1485
1486 #### 2-Node-Denverton Wiring (2n-dnv) PROD
1487
1488 ```
1489 - testbed26:
1490     - ring1 10GE-ports x553 copper port on SUT:
1491         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1492         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1493     - ring2 10GE-ports x553 fiber port on SUT:
1494         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1495         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1496 ```
1497
1498 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1499
1500 ```
1501 - testbed25:
1502     - link1 10GE-port x710-4p10GE on SUT:
1503         - t25-tg1-p1 to t25-sut1-c2/p1.
1504     - link2 10GE-port x710-4p10GE on SUT:
1505         - t25-tg1-p2 to t25-sut1-c2/p2.
1506     - link3 10GE-port x710-4p10GE on SUT:
1507         - t25-tg1-p3 to t25-sut1-c2/p3.
1508     - link4 10GE-port x710-4p10GE on SUT:
1509         - t25-tg1-p4 to t25-sut1-c2/p4.
1510 ```
1511
1512 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1513
1514 ```
1515 - testbed27:
1516     - ring1 10GE-ports x710-4p10GE on SUT:
1517         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1518         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1519     - ring2 10GE-ports x710-4p10GE on SUT:
1520         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1521         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1522     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1523         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1524         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1525     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1526         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1527         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1528     - ring5 100GE-ports e810-2p100GE on SUT:
1529         - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1530         - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1531 - testbed28:
1532     - ring1 10GE-ports x710-4p10GE on SUT:
1533         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1534         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1535     - ring2 10GE-ports x710-4p10GE on SUT:
1536         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1537         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1538     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1539         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1540         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1541     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1542         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1543         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1544     - ring5 100GE-ports e810-2p100GE on SUT:
1545         - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1546         - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1547 - testbed29:
1548     - ring1 10GE-ports x710-4p10GE on SUT:
1549         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1550         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1551     - ring2 10GE-ports x710-4p10GE on SUT:
1552         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1553         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1554     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1555         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1556         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1557     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1558         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1559         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1560     - ring6 100GE-ports e810-2p100GE on SUT:
1561         - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1562         - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1563 ```
1564
1565 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1566
1567 ```
1568 - testbed210:
1569     - ring1 10GE-ports x710-4p10GE on SUT:
1570         - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1571         - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1572     - ring2 10GE-ports x710-4p10GE on SUT:
1573         - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1574         - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1575     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1576         - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1577         - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1578     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1579         - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1580         - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1581 ```
1582
1583 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
1584
1585 ```
1586 - testbed34:
1587     - ring1 10GE-ports x520-2p10GE on SUTs:
1588         - s27-t34-sut1-c18/p1 - s19-t33t34-tg1-c8/p1.
1589         - s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2.
1590 ```
1591
1592 #### 3-Node-Skylake Wiring (3n-skx) PROD
1593
1594 ```
1595 - testbed31:
1596     - ring1 10GE-ports x710-4p10GE on SUTs:
1597         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1598         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1599         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1600     - ring2 10GE-ports x710-4p10GE on SUT:
1601         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1602         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1603         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1604     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1605         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1606         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1607         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1608     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1609         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1610         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1611         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1612     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1613         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1614         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1615 - testbed32:
1616     - ring1 10GE-ports x710-4p10GE on SUTs:
1617         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1618         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1619         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1620     - ring2 10GE-ports x710-4p10GE on SUT:
1621         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1622         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1623         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1624     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1625         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1626         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1627         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1628     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1629         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1630         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1631         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1632     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1633         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1634         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1635 ```
1636
1637 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1638
1639 ```
1640 To be completed.
1641 ```
1642
1643 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1644
1645 ```
1646 - testbed33:
1647     - ring1 10GE-ports x520-2p10GE on SUTs:
1648         - s19-t33t34-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1649         - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1650         - s18-t33-sut2-c6/p1 - s19-t33t34-tg1-c2/p1.
1651     - ring2 25GE-ports cx4-2p25GE on SUTs:
1652         - s19-t33t34-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1653         - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1654         - s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1.
1655 ```
1656
1657 #### 3-Node-Denverton Wiring (3n-dnv) PROD
1658
1659 ```
1660 - testbed35:
1661     - ring1 10GE-ports x553 copper port on SUTs:
1662         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1663         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1664         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1665     - ring2 10GE-ports x553 fiber port on SUTs:
1666         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1667         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1668         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1669 ```
1670
1671 ## Inventory
1672
1673 ### Appliances
1674
1675 ```
1676 1. Ixia PerfectStorm One Appliance
1677     - 1 * PS10GE4NG
1678         - Chassis: PS10GE4NG.
1679         - Motherboard: SuperMicro X11DPG-QT.
1680         - Processors: Quad-Core, Intel Processor.
1681         - HW accelerators: FPGA offload.
1682         - RAM Memory: 64GB.
1683         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1684         - Physical Interfaces: 4 * 10GE SFP+.
1685         - Operating System: Native IxOS.
1686 ```
1687
1688 ### Arm Servers
1689
1690 ```
1691 1. Arm Cortex A-72 servers
1692     - 2 * ThunderX2 (VPP Device)
1693         - Chassis: GIGABYTE Rack Mount
1694         - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
1695         - RAM Memory: 16* 16GB DIMM
1696         - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1697     - 1 * ThunderX2 (Performance)
1698         - Chassis: GIGABYTE Rack Mount
1699         - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
1700         - RAM Memory: 4* 32GB RDIMM
1701         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1702     - 2 * Huawei TaiShan 2280.
1703         - Chassis: Huawei TaiShan 2280.
1704         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
1705         - RAM Memory: 8* 16GB DDR4-2400MT/s.
1706         - Disks: 1* 4TB SATA HDD.
1707 ```
1708
1709 ### Xeon and Atom Servers
1710
1711 ```
1712 1. Intel Xeon servers:
1713     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1714         - Chassis: SuperMicro SYS-7049GP-TRT.
1715         - Motherboard: SuperMicro X11DPG-QT.
1716         - Processors: 2* Intel Platinum 8180 2.5 GHz.
1717         - RAM Memory: 16* 16GB DDR4-2666MHz.
1718         - Disks: 2* 1.6TB 6G SATA SSD.
1719 2. Intel Atom servers with Rangely processors.
1720     - 3 * Netgate XG-2758-1u
1721         - Chassis: Netgate XG-2758-1u
1722         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1723         - RAM Memory: 16GB ECC
1724         - Disks: 150 GB
1725 ```
1726
1727 ### Network Interface Cards
1728
1729 ```
1730 1. 10GE NICs
1731     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1732     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1733     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1734 2. 25GE NICs
1735     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1736 3. 40GE NICs
1737     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1738 4. 100GE NICs
1739     - 4 * mcx556a-edat NICs (not on site yet, in transit)
1740 ```
1741
1742 ### Pluggables and Cables
1743
1744 Pluggables:
1745
1746 ```
1747 1. 10GE SFP+
1748     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1749     - 80 * 10G SR optic (generic, "Intel" compatible branded)
1750 2. 25GE SFP28
1751     - None
1752 3. 40GE QSFP+
1753     - None
1754 4. 100GE
1755     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1756 ```
1757
1758 Standalone cables:
1759
1760 ```
1761 1. 10GE
1762     - None
1763 2. 25GE
1764     - None
1765 3. 40GE QSFP+
1766     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
1767 4. 100GE
1768     - None
1769 ```
1770
1771 ### Other Parts