lab WIP: add new 3n-alt Arm testbed
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14    1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
15    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
16    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
17    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
18    1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
19 1. [Server Management](#server-management)
20    1. [Requirements](#requirements)
21    1. [Addressing](#addressing)
22    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
23    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
24 1. [Server Specifications](#server-specifications)
25    1. [Server Types](#server-types)
26    1. [Naming Convention](#naming-convention)
27 1. [Testbeds Configuration](#testbeds-configuration)
28    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
29       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
30       1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
31       1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
32       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
33       1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
34       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
35       1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
36       1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
37       1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
38       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
39       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
40       1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
41       1. [3-Node-Altra Servers (3n-alt) TBD](#3-node-altra-servers-3n-alt-tbd)
42    1. [Per Testbed Wiring](#per-testbed-wiring)
43       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
44       1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
45       1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
46       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
47       1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
48       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
49       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
50       1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
51       1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
52       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
53       1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
54       1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
55       1. [3-Node-Altra Wiring (3n-alt) TBD](#3-node-altra-wiring-3n-alt-tbd)
56 1. [Inventory](#inventory)
57    1. [Appliances](#appliances)
58    1. [Arm Servers](#arm-servers)
59    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
60    1. [Network Interface Cards](#network-interface-cards)
61    1. [Pluggables and Cables](#pluggables-and-cables)
62    1. [Other Parts](#other-parts)
63
64 ## Purpose
65
66 This note includes specification of the physical testbed infrastructure
67 hosted by LFN FD.io CSIT project.
68
69 ## Testbeds Overview
70
71 ### Summary List
72
73 ```
74  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2
75  1. 1-Node-Haswell     nomad  hsw   na    4    4    0    4    0    0    0    0    0    0    0    0    0
76  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0    0
77  3. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0    0
78  4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0    1    0
79  5. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0    0    0
80  6. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0    0
81  7. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0    0
82  8. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0    6    0
83  9. 2-Node-ThunderX2   perf   tx2   skx   1    1    .5   0    .5   0    0    0    1    0    0    0    0
84 10. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0    0
85 11. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0    0
86 12. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0    0
87 13. 3-Node-Altra       perf   alt   tbd   1    2    tbd  0    0    0    0    0    0    0    2    0    0
88 14. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0    0
89 15. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    0    2
90                                  Totals: 26   33   15    4   19    1    2    3    3    2    2    7    2
91 ```
92
93 ### 1-Node-Skylake Xeon Intel (1n-skx)
94
95 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
96 ports connected back-to-back ([Server Types](#server-types)).
97 Used for FD.io VPP_Device functional driver tests.
98
99 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
100
101 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
102 ports connected back-to-back ([Server Types](#server-types)).
103 Used for FD.io VPP_Device functional driver tests.
104
105 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
106
107 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
108 NIC ports connected back-to-back ([Server Types](#server-types)).
109
110 Used for FD.io VPP_Device functional driver tests.
111
112 ### 2-Node-Skylake Xeon Intel (2n-skx)
113
114 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
115 (Server-Type-B2) connected in a 2-node circular topology
116 ([Server Types](#server-types)).
117 Used for FD.io performance tests.
118
119 ### 2-Node-Denverton Atom Intel (2n-dnv)
120
121 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
122 TG (Server-Type-B2) connected in a 2-node circular topology
123 ([Server Types](#server-types)).
124 Used for FD.io performance tests.
125
126 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
127
128 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
129 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
130 circular topology ([Server Types](#server-types)).
131 Used for FD.io TCP/IP and HTTP performance tests.
132
133 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
134
135 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
136 one TG (Server-Type-C3) connected in a 2-node circular topology
137 ([Server Types](#server-types)).
138 Used for FD.io performance tests.
139
140 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
141
142 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
143 one TG (Server-Type-D2) connected in a 2-node circular topology
144 ([Server Types](#server-types)).
145 Used for FD.io performance tests.
146
147 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
148
149 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
150 one TG (Server-Type-E31) connected in a 2-node circular topology
151 ([Server Types](#server-types)).
152 Used for FD.io performance tests.
153
154 ### 3-Node-Haswell Xeon Intel (3n-hsw)
155
156 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
157 TG (Server-Type-A2) connected in a 3-node circular topology
158 ([Server Types](#server-types)).
159 Used for FD.io performance tests.
160
161 ### 3-Node-Skylake Xeon Intel (3n-skx)
162
163 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
164 TG (Server-Type-B2) connected in a 3-node circular topology.
165 Used for FD.io performance tests.
166
167 ### 3-Node-Rangeley Atom Testbeds
168
169 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
170 TG (Server-Type-2) connected in a 3-node circular topology
171 ([Server Types](#server-types)).
172 Used for FD.io performance tests.
173
174 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
175
176 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
177 TG (Server-Type-E31) connected in a 3-node circular topology
178 ([Server Types](#server-types)).
179 Used for FD.io performance tests.
180
181 ### 3-Node-Altra Arm Ampere (3n-alt)
182
183 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
184 TG (TBD Server-Type-xxx) connected in a 3-node circular topology
185 ([Server Types](#server-types)).
186 Used for FD.io performance tests.
187
188 ## Server Management
189
190 ### Requirements
191
192 For management purposes, each server must have following two ports
193 connected to the management network:
194
195 ```
196 - 1GE IPMI port
197   - IPMI - Intelligent Platform Management Interface.
198   - Required for access to embedded server management with WebUI, CLI,
199     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
200 - 1GE/10GE/40GE management port
201   - hostOS management port for general system management.
202 ```
203
204 ### Addressing
205
206 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
207 Management port, which are connected to two different VLANs.
208
209 ```
210 1. LOM (IPMI) VLAN:
211     - Subnet: 10.30.50.0/24
212     - Gateway: 10.30.50.1
213     - Broadcast: 10.30.50.255
214     - DNS1: 199.204.44.24
215     - DNS2: 199.204.47.54
216 2. Management Vlan:
217     - Subnet: 10.30.51.0/24
218     - Gateway: 10.30.51.1
219     - Broadcast: 10.30.51.255
220     - DNS1: 199.204.44.24
221     - DNS2: 199.204.47.54
222 ```
223
224 To access these hosts, VPN connection is required.
225
226 ### LOM (IPMI) VLAN IP Addresses
227
228 Name         | Comment
229 ------------ | -------
230 10.30.50.0   | network
231 10.30.51.1   | Router
232 10.30.50.2   | LF Reserved
233 10.30.50.3   | LF Reserved
234 10.30.50.4   | LF Reserved
235 10.30.50.5   | LF Reserved
236 10.30.50.6   | LF Reserved
237 10.30.50.7   | LF Reserved
238 10.30.50.8   | LF Reserved
239 10.30.50.9   | LF Reserved
240 10.30.50.10  | LF Reserved
241 10.30.50.11  | LF Reserved
242 10.30.50.12  | LF Reserved
243 10.30.50.13  | LF Reserved
244 10.30.50.14  | LF Reserved
245 10.30.50.15  | LF Reserved
246 10.30.50.22  | s42-nomad
247 10.30.50.24  | s43-nomad
248 10.30.50.25  | s44-nomad
249 10.30.50.26  | s45-nomad
250 10.30.50.28  | s41-nomad
251 10.30.50.29  | s39-nomad
252 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
253 10.30.50.30  | s40-nomad
254 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
255 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
256 10.30.50.36  | s17-t33-sut1
257 10.30.50.37  | s18-t33-sut2
258 10.30.50.38  | fdio-marvell-dev
259 10.30.50.39  | s53-nomad
260 10.30.50.40  | s54-nomad
261 10.30.50.41  | s3-t21-sut1
262 10.30.50.42  | s4-t21-tg1
263 10.30.50.43  | s11-t31-sut1
264 10.30.50.44  | s12-t31-sut2
265 10.30.50.45  | s13-t31-tg1
266 10.30.50.46  | s19-t33t211-tg1
267 10.30.50.47  | s1-t11-sut1
268 10.30.50.48  | s2-t12-sut1
269 10.30.50.49  | s5-t22-sut1
270 10.30.50.50  | s6-t22-tg1
271 10.30.50.51  | s7-t23-sut1
272 10.30.50.52  | s8-t23-tg1
273 10.30.50.53  | s9-t24-sut1
274 10.30.50.54  | s10-t24-tg1
275 10.30.50.55  | s14-t32-sut1
276 10.30.50.56  | s15-t32-sut2
277 10.30.50.57  | s16-t32-tg1
278 10.30.50.58  | s25-t25-sut1
279 10.30.50.59  | s26-t25-tg1
280 10.30.50.65  | s52-nomad
281 10.30.50.66  | s51-nomad
282 10.30.50.67  | s49-nomad
283 10.30.50.68  | s50-nomad
284 10.30.50.69  | s27-t211-sut1
285 10.30.50.70  | s55-t13-sut1
286 10.30.50.71  | s56-t14-sut1
287 10.30.50.72  | s62-t34-sut1
288 10.30.50.73  | s63-t34-sut2
289 10.30.50.74  | s64-t34-tg1
290 10.30.50.255 | Broadcast
291 10.30.55.0   | network
292 10.30.55.1   | Router
293 10.30.55.10  | s28-t26t35-tg1
294 10.30.55.11  | s29-t26-sut1
295 10.30.55.12  | s30-t35-sut1
296 10.30.55.13  | s31-t35-sut2
297 10.30.55.14  | s46-nomad
298 10.30.55.15  | s47-nomad
299 10.30.55.16  | s48-nomad
300 10.30.55.17  | s57-nomad
301 10.30.55.18  | s33-t27-sut1
302 10.30.55.19  | s34-t27-tg1
303 10.30.55.20  | s35-t28-sut1
304 10.30.55.21  | s36-t28-tg1
305 10.30.55.22  | s37-t29-sut1
306 10.30.55.23  | s38-t29-tg1
307 10.30.55.24  | s60-t210-sut1
308 10.30.55.25  | s61-t210-tg1
309 10.30.55.255 | Broadcast
310
311 ### Management VLAN IP Addresses
312
313 Name                      | Comment
314 ------------------------- | -------
315 10.30.51.0                | network
316 10.30.51.1                | Router
317 10.30.51.2                | LF Reserved
318 10.30.51.3                | LF Reserved
319 10.30.51.4                | LF Reserved
320 10.30.51.5                | LF Reserved
321 10.30.51.6                | LF Reserved
322 10.30.51.7                | LF Reserved
323 10.30.51.8                | LF Reserved
324 10.30.51.15               | LF Reserved
325 10.30.51.22               | s42-nomad
326 10.30.51.24               | s43-nomad
327 10.30.51.25               | s44-nomad
328 10.30.51.26               | s45-nomad
329 10.30.51.28               | s41-nomad
330 10.30.51.29               | s39-nomad
331 10.30.51.30               | s40-nomad
332 10.30.51.36               | s17-t33-sut1
333 10.30.51.37               | s18-t33-sut2
334 10.30.51.38               | fdio-marvell-dev
335 10.30.51.39               | s53-nomad
336 10.30.51.40               | s54-nomad
337 10.30.51.44               | s3-t21-sut1
338 10.30.51.45               | s4-t21-tg1
339 10.30.51.46               | s11-t31-sut1
340 10.30.51.47               | s12-t31-sut2
341 10.30.51.48               | s13-t31-tg1
342 10.30.51.49               | s19-t33t211-tg1
343 10.30.51.50               | s1-t11-sut1
344 10.30.51.51               | s2-t12-sut1
345 10.30.51.52               | s5-t22-sut1
346 10.30.51.53               | s6-t22-tg1
347 10.30.51.54               | s7-t23-sut1
348 10.30.51.55               | s8-t23-tg1
349 10.30.51.56               | s9-t24-sut1
350 10.30.51.57               | s10-t24-tg1
351 10.30.51.58               | s14-t32-sut1
352 10.30.51.59               | s15-t32-sut2
353 10.30.51.60               | s16-t32-tg1
354 10.30.51.61               | s25-t25-sut1
355 10.30.51.62               | s26-t25-tg1
356 10.30.51.65               | s52-nomad
357 10.30.51.66               | s51-nomad
358 10.30.51.67               | s49-nomad
359 10.30.51.68               | s50-nomad
360 10.30.51.69               | s27-t211-sut1
361 10.30.51.70               | s55-t13-sut1
362 10.30.51.71               | s56-t14-sut1
363 10.30.51.72               | s62-t34-sut1
364 10.30.51.73               | s63-t34-sut2
365 10.30.51.74               | s64-t34-tg1
366 10.30.51.75-10.30.51.254  | FREE
367 10.30.51.255              | Broadcast
368 10.32.8.0                 | network
369 10.32.8.1                 | Router
370 10.32.8.10                | s28-t26t35-tg1
371 10.32.8.11                | s29-t26-sut1
372 10.32.8.12                | s30-t35-sut1
373 10.32.8.13                | s31-t35-sut2
374 10.32.8.14                | s46-nomad
375 10.32.8.15                | s47-nomad
376 10.32.8.16                | s48-nomad
377 10.32.8.17                | s57-nomad
378 10.32.8.18                | s33-t27-sut1
379 10.32.8.19                | s34-t27-tg1
380 10.32.8.20                | s35-t28-sut1
381 10.32.8.21                | s36-t28-tg1
382 10.32.8.22                | s37-t29-sut1
383 10.32.8.23                | s38-t29-tg1
384 10.32.8.24                | s60-t210-sut1
385 10.32.8.25                | s61-t210-tg1
386 10.32.8.255               | Broadcast
387
388 ## Server Specifications
389
390 ### Server Types
391
392 FD.io CSIT lab contains following server types:
393 ```
394 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
395     - Quantity: 6 servers.
396     - Physical connectivity:
397         - CIMC and host management ports.
398         - NIC ports connected in 3-node topologies.
399     - Main HW configuration:
400         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
401         - Processors: 2* E5-2699v3 2.3 GHz.
402         - RAM Memory: 16* 32GB DDR4-2133MHz.
403         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
404     - NICs configuration:
405         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
406             - PCIe Slot1: empty.
407             - PCIe Slot2: empty.
408             - PCIe Slot3: empty.
409         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
410             - PCIe Slot4: empty.
411             - PCIe Slot5: empty.
412             - PCIe Slot6: empty
413         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
414 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
415     - Quantity: 3 servers.
416     - Physical connectivity:
417         - CIMC and host management ports.
418         - NIC ports connected in 3-node topologies.
419     - Main HW configuration:
420         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
421         - Processors: 2* E5-2699v3 2.3 GHz.
422         - RAM Memory: 16* 32GB DDR4-2133MHz.
423         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
424     - NICs configuration:
425         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
426             - PCIe Slot1: empty.
427             - PCIe Slot2: empty.
428             - PCIe Slot3: empty.
429         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
430             - PCIe Slot4: empty.
431             - PCIe Slot5: empty.
432             - PCIe Slot6: empty
433         - MLOM slot: empty.
434 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
435     - Quantity: 3 servers.
436     - Physical connectivity:
437         - CIMC and host management ports.
438         - no NIC ports, standalone setup.
439     - Main HW configuration:
440         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
441         - Processors: 2* E5-2699v3 2.3 GHz.
442         - RAM Memory: 16* 32GB DDR4-2133MHz.
443         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
444     - NICs configuration:
445         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
446             - no cards.
447         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
448             - no cards.
449         - MLOM slot: empty.
450 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
451     - Quantity: ---
452     - Physical connectivity:
453         - IPMI and host management ports.
454         - NIC ports connected into 2-node and 3-node topologies.
455     - Main HW configuration:
456         - Chassis: SuperMicro SYS-7049GP-TRT.
457         - Motherboard: SuperMicro X11DPG-QT.
458         - Processors: 2* Intel Platinum 8180 2.5 GHz.
459         - RAM Memory: 16* 16GB DDR4-2666MHz.
460         - Disks: 2* 1.6TB 6G SATA SSD.
461     - NICs configuration:
462         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
463             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
464             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
465             - PCIe Slot9 5e:00.xx: empty.
466         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
467             - PCIe Slot6 86:00.xx: empty.
468             - PCIe Slot8 af:00.xx: empty.
469             - PCIe Slot10 d8:00.xx: empty.
470 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
471     - Quantity: ---
472     - Physical connectivity:
473         - IPMI and host management ports.
474         - NIC ports connected into 2-node and 3-node topologies.
475     - Main HW configuration:
476         - Chassis: SuperMicro SYS-7049GP-TRT.
477         - Motherboard: SuperMicro X11DPG-QT.
478         - Processors: 2* Intel Platinum 8180 2.5 GHz.
479         - RAM Memory: 16* 16GB DDR4-2666MHz.
480         - Disks: 2* 1.6TB 6G SATA SSD.
481     - NICs configuration:
482         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
483             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
484             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
485             - PCIe Slot9 5e:00.xx: empty.
486         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
487             - PCIe Slot6 86:00.xx: empty.
488             - PCIe Slot8 af:00.xx: empty.
489             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
490 6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
491     - Quantity: TBD based on testbed allocation.
492     - Physical connectivity:
493         - Management: serial Port (usb) for console
494         - NIC ports connected into 2-node.
495     - Main HW configuration:
496         - Chassis: Netgate XG-2758-1u
497         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
498         - RAM Memory: 16GB ECC
499         - Disks: 150 GB
500     - NICs configuration:
501         - 2x 10Gb Intel 82599ES
502         - 4x 1GB Intel I354
503 7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
504     - Quantity: 2.
505     - Physical connectivity:
506         - IPMI and host management ports.
507         - NIC ports connected into 1-node topologies.
508     - Main HW configuration:
509         - Chassis: SuperMicro SYS-7049GP-TRT.
510         - Motherboard: SuperMicro X11DPG-QT.
511         - Processors: 2* Intel Platinum 8180 2.5 GHz.
512         - RAM Memory: 16* 16GB DDR4-2666MHz.
513         - Disks: 2* 1.6TB 6G SATA SSD.
514     - NICs configuration:
515         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
516             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
517             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
518             - PCIe Slot9 5e:00.xx: empty.
519         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
520             - PCIe Slot6 86:00.xx: empty.
521             - PCIe Slot8 af:00.xx: empty.
522             - PCIe Slot10 d8:00.xx: empty.
523 8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
524     - Quantity: 1.
525     - Physical connectivity:
526         - Host management interface: 10/100/1000-BaseT.
527         - 8-port 10GE SFP+ integrated NIC.
528     - Main HW configuration:
529         - Chassis: PS10GE4NG.
530         - Motherboard: SuperMicro X11DPG-QT.
531         - Processors: Quad-Core, Intel Processor.
532         - HW accelerators: FPGA offload.
533         - RAM Memory: 64GB.
534         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
535         - Physical Interfaces: 4 * 10GE SFP+.
536         - Operating System: Native IxOS.
537     - Interface configuration:
538         - Port-1: 10GE SFP+.
539         - Port-2: 10GE SFP+.
540         - Port-3: 10GE SFP+.
541         - Port-4: 10GE SFP+.
542 9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
543     - Quantity: 1.
544     - Physical connectivity:
545         - IPMI and host management ports.
546         - NIC ports.
547     - Main HW configuration:
548         - Chassis: SuperMicro SYS-7049GP-TRT.
549         - Motherboard: SuperMicro X11DPG-QT.
550         - Processors: 2* Intel Platinum 8180 2.5 GHz.
551         - RAM Memory: 16* 16GB DDR4-2666MHz.
552         - Disks: 2* 1.6TB 6G SATA SSD.
553     - NICs configuration:
554         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
555             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
556             - PCIe Slot4 3b:00.xx: empty.
557             - PCIe Slot9 5e:00.xx: empty.
558         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
559             - PCIe Slot6 86:00.xx: empty.
560             - PCIe Slot8 af:00.xx: empty.
561             - PCIe Slot10 d8:00.xx: empty.
562 10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
563     - Quantity: 4
564     - Physical connectivity:
565         - IPMI and host management ports.
566         - NIC ports.
567     - Main HW configuration:
568         - Chassis: SuperMicro SYS-E300-9A
569         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
570         - RAM Memory: 32GB ECC
571         - Disks: 480 GB
572     - NICs configuration:
573         - 2x 10Gb Intel x553 fiber ports
574         - 2x 10Gb Intel x553 copper ports
575         - 4x 1GB Intel I350 ports
576 11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
577     - Quantity: 1.
578     - Physical connectivity:
579         - IPMI and host management ports.
580         - NIC ports connected into 1-node testbed topologies.
581     - Main HW configuration:
582         - Chassis: SuperMicro SYS-7049GP-TRT.
583         - Motherboard: SuperMicro X11DPG-QT.
584         - Processors: 2* Intel Platinum 8280 2.7 GHz.
585         - RAM Memory: 12* 16GB DDR4-2933.
586         - Disks: 2* 1.92TB SATA SSD.
587     - NICs configuration:
588         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
589             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
590             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
591             - PCIe Slot9 5e:00.xx: empty.
592         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
593             - PCIe Slot6 86:00.xx: empty.
594             - PCIe Slot8 af:00.xx: empty.
595             - PCIe Slot10 d8:00.xx: empty.
596 12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
597     - Quantity: 3
598     - Physical connectivity:
599         - IPMI and host management ports.
600         - NIC ports connected into 2-node testbed topologies.
601     - Main HW configuration:
602         - Chassis: SuperMicro SYS-7049GP-TRT.
603         - Motherboard: SuperMicro X11DPG-QT.
604         - Processors: 2* Intel Gold 6252N 2.3 GHz.
605         - RAM Memory: 12* 16GB DDR4-2933.
606         - Disks: 2* 1.92TB SATA SSD.
607     - NICs configuration:
608         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
609             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
610             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
611             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
612         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
613             - PCIe Slot6 86:00.xx: empty.
614             - PCIe Slot8 af:00.xx: empty.
615             - PCIe Slot10 d8:00.xx: empty.
616 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
617     - Quantity: 3.
618     - Physical connectivity:
619         - IPMI and host management ports.
620         - NIC ports connected into 2-node testbed topologies.
621     - Main HW configuration:
622         - Chassis: SuperMicro SYS-7049GP-TRT.
623         - Motherboard: SuperMicro X11DPG-QT.
624         - Processors: 2* Intel Platinum 8280 2.7 GHz.
625         - RAM Memory: 12* 16GB DDR4-2933.
626         - Disks: 2* 1.92TB SATA SSD.
627     - NICs configuration:
628         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
629             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
630             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
631             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
632         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
633             - PCIe Slot6 86:00.xx: empty.
634             - PCIe Slot8 af:00.xx: empty.
635             - PCIe Slot10 d8:00.xx: empty.
636 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
637     - Quantity: 3.
638     - Physical connectivity:
639         - CIMC and host management ports.
640         - no NIC ports, standalone setup.
641     - Main HW configuration:
642         - Chassis: SuperMicro 1029P-WTRT.
643         - Motherboard: SuperMicro X11DDW-NT.
644         - Processors: 2* Intel Platinum 8280 2.7 GHz.
645         - RAM Memory: 12* 16GB DDR4-2933.
646         - Disks: 4* 1.92TB SATA SSD.
647     - NICs configuration:
648         - Numa0:
649             - no cards.
650         - Numa1:
651             - no cards.
652 15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
653     - Quantity: 1.
654     - Physical connectivity:
655         - IPMI and host management ports.
656         - NIC ports connected into 2-node testbed topologies.
657     - Main HW configuration:
658         - Chassis: SuperMicro AS-1114S-WTRT
659         - Processors: 1* AMD EPYC 7532 2.4 GHz.
660         - RAM Memory: 8* 32GB DDR4-2933.
661         - Disks: 1* 1TB SATA SSD.
662     - NICs configuration:
663         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
664             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
665             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
666             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
667 16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
668     - Quantity: 1.
669     - Physical connectivity:
670         - IPMI and host management ports.
671         - NIC ports connected into 2-node testbed topologies.
672     - Main HW configuration:
673         - Chassis: SuperMicro AS-1114S-WTRT
674         - Processors: 1* AMD EPYC 7532 2.4 GHz.
675         - RAM Memory: 8* 32GB DDR4-2933.
676         - Disks: 1* 1TB SATA SSD.
677     - NICs configuration:
678         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
679             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
680             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
681             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
682 17.  Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
683     - Quantity: 2
684     - Physical connectivity:
685         - IPMI and host management ports.
686         - NIC ports connected into 1-node topologies.
687     - Main HW configuration:
688         - Chassis: GIGABYTE Rack Mount
689         - Motherboard: MT91-FS4-00
690         - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
691         - RAM Memory: 16 * 16GB DIMM
692         - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
693     - NICs configuration:
694         - Numa0:
695             - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
696             - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
697         - Numa1:
698             - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
699             - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
700 18.  Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
701     - Quantity: 2
702     - Physical connectivity:
703         - IPMI(?) and host management ports.
704         - NIC ports connected into 3-node topology.
705     - Main HW configuration:
706         - Chassis: Huawei TaiShan 2280.
707         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
708         - RAM Memory: 8* 16GB DDR4-2400MT/s
709         - Disks: 1* 4TB SATA HDD
710     - NICs configuration:
711         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
712         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
713 19.  Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
714     - Quantity: 1
715     - Physical connectivity:
716         - IPMI and host management ports.
717         - NIC ports connected into 2-node topologies.
718     - Main HW configuration:
719         - Chassis: Gigabyte R181-T90 1U
720         - Motherboard: MT91-FS1
721         - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
722         - RAM Memory: 4* 32GB RDIMM
723         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
724     - NICs configuration:
725         - Numa0:
726             - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
727         - Numa1:
728             - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
729 20.  Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
730     - Quantity: 1
731     - Physical connectivity:
732         - IPMI and host management ports.
733         - NIC ports connected into 3-node topologies.
734     - Main HW configuration:
735         - Chassis: TBD
736         - Motherboard: TBD
737         - Processors: n* TBD
738         - RAM Memory: n* TBD
739         - Disks: TBD
740     - NICs configuration:
741         - Numa0:
742             - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
743             - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
744         - Numa1:
745             - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
746             - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
747 21.  Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
748     - Quantity: 1
749     - Physical connectivity:
750         - IPMI and host management ports.
751         - NIC ports connected into 2-node and 3-node topologies.
752     - Main HW configuration:
753         - Chassis: SuperMicro SYS-7049GP-TRT.
754         - Motherboard: SuperMicro X11DPG-QT.
755         - Processors: 2* Intel Platinum 8180 2.5 GHz.
756         - RAM Memory: 16* 16GB DDR4-2666MHz.
757         - Disks: 2* 1.6TB 6G SATA SSD.
758     - NICs configuration:
759         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
760             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
761             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
762             - PCIe Slot9 5e:00.xx: empty.
763         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
764             - PCIe Slot6 86:00.xx: empty.
765             - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
766             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
767 ```
768
769 ### Naming Convention
770
771 Following naming convention is used within this page to specify physical
772 connectivity and wiring across defined CSIT testbeds:
773
774 ```
775 - testbedname: testbedN.
776 - hostname:
777     - traffic-generator: tN-tgW.
778     - system-under-testX: tN-sutX.
779 - portnames:
780     - tN-tgW-cY/pZ.
781     - tN-sutX-cY/pZ.
782 - where:
783     - N - testbed number.
784     - tgW - server acts as traffic-generator with W index.
785     - sutX - server acts as system-under-test with X index.
786     - Y - PCIe slot number denoting a NIC card number within the host.
787     - Z - port number on the NIC card.
788 ```
789
790 ## Testbeds Configuration
791
792 ### Per Testbed Server Allocation and Naming
793
794 #### 1-Node-Skylake Servers (1n-skx) PROD
795
796 ```
797 - SUT [Server-Type-B6]:
798     - testbedname: testbed11.
799     - hostname: s1-t11-sut1.
800     - IPMI IP: 10.30.50.47
801     - Host IP: 10.30.51.50
802     - portnames:
803         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
804         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
805         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
806         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
807         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
808         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
809         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
810         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
811 - SUT [Server-Type-B6]:
812     - testbedname: testbed12.
813     - hostname: s2-t12-sut1.
814     - IPMI IP: 10.30.50.48
815     - Host IP: 10.30.51.51
816     - portnames:
817         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
818         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
819         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
820         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
821         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
822         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
823         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
824         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
825 ```
826
827 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
828
829 ```
830 - SUT [Server-Type-E11]:
831     - testbedname: testbed13
832     - hostname: s55-t13-sut1
833     - IPMI IP: 10.30.50.70
834     - Host IP: 10.30.51.70
835     - portnames:
836         - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
837         - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
838         - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
839         - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
840         - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
841         - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
842         - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
843         - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
844 - SUT [Server-Type-E11]:
845     - testbedname: testbed14
846     - hostname: s56-t14-sut1
847     - IPMI IP: 10.30.50.71
848     - Host IP: 10.30.51.71
849     - portnames:
850         - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
851         - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
852         - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
853         - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
854         - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
855         - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
856         - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
857         - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
858 ```
859
860 #### 1-Node-Cascadelake Servers (1n-clx) PROD
861
862 ```
863 - SUT [Server-Type-C1]:
864     - testbedname: testbed11.
865     - hostname: s32-t14-sut1.
866     - IPMI IP: 10.30.55.17
867     - Host IP: 10.32.8.17
868     - portnames:
869         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
870         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
871         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
872         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
873         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
874         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
875         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
876         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
877 ```
878
879 #### 2-Node-Skylake Servers (2n-skx) PROD
880
881 ```
882 - SUT [Server-Type-B1]:
883     - testbedname: testbed21.
884     - hostname: s3-t21-sut1.
885     - IPMI IP: 10.30.50.41
886     - Host IP: 10.30.51.44
887     - portnames:
888         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
889         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
890         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
891         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
892         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
893         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
894 - TG [Server-Type-B2]:
895     - testbedname: testbed21.
896     - hostname: s4-t21-tg1.
897     - IPMI IP: 10.30.50.42
898     - Host IP: 10.30.51.45
899     - portnames:
900         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
901         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
902         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
903         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
904         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
905         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
906         - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
907         - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
908         - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
909         - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
910 - SUT [Server-Type-B1]:
911     - testbedname: testbed22.
912     - hostname: s5-t22-sut1.
913     - IPMI IP: 10.30.50.49
914     - Host IP: 10.30.51.52
915     - portnames:
916         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
917         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
918         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
919         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
920         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
921         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
922 - TG [Server-Type-B2]:
923     - testbedname: testbed22.
924     - hostname: s6-t22-tg1.
925     - IPMI IP: 10.30.50.50
926     - Host IP: 10.30.51.53
927     - portnames:
928         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
929         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
930         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
931         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
932         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
933         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
934         - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
935         - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
936         - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
937         - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
938 - SUT [Server-Type-B1]:
939     - testbedname: testbed23.
940     - hostname: s7-t23-sut1.
941     - IPMI IP: 10.30.50.51
942     - Host IP: 10.30.51.54
943     - portnames:
944         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
945         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
946         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
947         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
948         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
949         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
950 - TG [Server-Type-B2]:
951     - testbedname: testbed23.
952     - hostname: s8-t23-tg1.
953     - IPMI IP: 10.30.50.52
954     - Host IP: 10.30.51.55
955     - portnames:
956         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
957         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
958         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
959         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
960         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
961         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
962         - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
963         - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
964         - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
965         - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
966 - SUT [Server-Type-B1]:
967     - testbedname: testbed24.
968     - hostname: s9-t24-sut1.
969     - IPMI IP: 10.30.50.53
970     - Host IP: 10.30.51.56
971     - portnames:
972         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
973         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
974         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
975         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
976         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
977         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
978 - TG [Server-Type-B2]:
979     - testbedname: testbed24.
980     - hostname: s10-t24-tg1.
981     - IPMI IP: 10.30.50.54
982     - Host IP: 10.30.51.57
983     - portnames:
984         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
985         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
986         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
987         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
988         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
989         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
990         - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
991         - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
992         - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
993         - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
994 ```
995
996 #### 2-Node-Denverton Servers (2n-dnv) PROD
997
998 Note: ServerB28 (TG) is shared between testbed26 & testbed35
999
1000 ```
1001 - TG [Server-Type-B2]:
1002     - testbednames: testbed26 and testbed35.
1003     - hostname: s28-t26t35-tg1.
1004     - IPMI IP: 10.30.55.10
1005     - Host IP: 10.32.8.10
1006     - portnames:
1007         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
1008         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
1009         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
1010         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
1011         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
1012         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
1013         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
1014         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
1015         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
1016         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
1017         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
1018         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
1019 - SUT [Server-Type-B10]:
1020     - testbednames: testbed26.
1021     - hostname: s29-t26-sut1.
1022     - IPMI IP: 10.30.55.11
1023     - Host IP: 10.32.8.11
1024     - portnames:
1025         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
1026         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
1027         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
1028         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
1029 ```
1030
1031 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
1032
1033 ```
1034 - SUT [Server-Type-B8]:
1035     - testbedname: testbed25.
1036     - hostname: s25-t25-sut1.
1037     - IPMI IP: 10.30.50.58
1038     - Host IP: 10.30.51.61
1039     - portnames:
1040         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1041         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1042         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1043         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1044 - TG [Server-Type-B7]:
1045     - testbedname: testbed25.
1046     - hostname: s26-t25-tg1.
1047     - IPMI IP: 10.30.50.59
1048     - Host IP: 10.30.51.62
1049     - portnames:
1050         - s26-t25-tg1-p1 - 10GE-port1.
1051         - s26-t25-tg1-p2 - 10GE-port2.
1052         - s26-t25-tg1-p3 - 10GE-port3.
1053         - s26-t25-tg1-p4 - 10GE-port4.
1054 ```
1055
1056 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1057
1058 ```
1059 - SUT [Server-Type-C2]:
1060     - testbedname: testbed27.
1061     - hostname: s33-t27-sut1.
1062     - IPMI IP: 10.30.55.18
1063     - Host IP: 10.32.8.18
1064     - portnames:
1065         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1066         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1067         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1068         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1069         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1070         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1071         - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1072         - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1073         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1074         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1075 - TG [Server-Type-C3]:
1076     - testbedname: testbed27.
1077     - hostname: s34-t27-tg1.
1078     - IPMI IP: 10.30.55.19
1079     - Host IP: 10.32.8.19
1080     - portnames:
1081         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1082         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1083         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1084         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1085         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1086         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1087         - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1088         - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1089         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1090         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1091 - SUT [Server-Type-C2]:
1092     - testbedname: testbed28.
1093     - hostname: s35-t28-sut1.
1094     - IPMI IP: 10.30.55.20
1095     - Host IP: 10.32.8.20
1096     - portnames:
1097         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1098         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1099         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1100         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1101         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1102         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1103         - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1104         - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1105         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1106         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1107 - TG [Server-Type-C3]:
1108     - testbedname: testbed28.
1109     - hostname: s36-t28-tg1.
1110     - IPMI IP: 10.30.55.21
1111     - Host IP: 10.32.8.21
1112     - portnames:
1113         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1114         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1115         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1116         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1117         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1118         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1119         - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1120         - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1121         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1122         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1123 - SUT [Server-Type-C2]:
1124     - testbedname: testbed29.
1125     - hostname: s37-t29-sut1.
1126     - IPMI IP: 10.30.55.22
1127     - Host IP: 10.32.8.22
1128     - portnames:
1129         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1130         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1131         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1132         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1133         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1134         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1135         - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1136         - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1137         - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1138         - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1139 - TG [Server-Type-C3]:
1140     - testbedname: testbed29.
1141     - hostname: s38-t29-tg1.
1142     - IPMI IP: 10.30.55.23
1143     - Host IP: 10.32.8.23
1144     - portnames:
1145         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1146         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1147         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1148         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1149         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1150         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1151         - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1152         - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1153         - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1154         - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1155 ```
1156
1157 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1158
1159 ```
1160 - SUT [Server-Type-D1]:
1161     - testbedname: testbed210.
1162     - hostname: s60-t210-sut1.
1163     - IPMI IP: 10.30.55.24
1164     - Host IP: 10.32.8.24
1165     - portnames:
1166         - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1167         - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1168         - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1169         - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1170         - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1171         - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1172         - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1173         - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1174 - TG [Server-Type-D2]:
1175     - testbedname: testbed210.
1176     - hostname: s61-t210-tg1.
1177     - IPMI IP: 10.30.55.25
1178     - Host IP: 10.32.8.25
1179     - portnames:
1180         - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1181         - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1182         - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1183         - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1184         - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1185         - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1186         - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1187         - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1188 ```
1189
1190 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1191
1192 Note: Server19 (TG) is shared between testbed33 & testbed211
1193
1194 ```
1195 - SUT [Server-Type-E22]:
1196     - testbedname: testbed211.
1197     - hostname: s27-t211-sut1.
1198     - IPMI IP: 10.30.50.69
1199     - Host IP: 10.30.51.69
1200     - portnames:
1201         - s27-t211-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1202         - s27-t211-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1203         - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1204         - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1205 - TG [Server-Type-E31]:
1206     - testbedname: testbed33 and testbed211.
1207     - hostname: s19-t33t211-tg1.
1208     - IPMI IP: 10.30.50.46
1209     - Host IP: 10.30.51.49
1210     - portnames:
1211         - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1212         - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1213         - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1214         - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1215         - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1216         - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1217         - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1218         - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1219         - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1220         - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1221         - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1222         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1223 ```
1224
1225 #### 3-Node-Skylake Servers (3n-skx) PROD
1226
1227 ```
1228 - ServerB11 [Server-Type-B1]:
1229     - testbedname: testbed31.
1230     - hostname: s11-t31-sut1.
1231     - IPMI IP: 10.30.50.43
1232     - Host IP: 10.30.51.46
1233     - portnames:
1234         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1235         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1236         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1237         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1238         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1239         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1240         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1241         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1242 - ServerB12 [Server-Type-B1]:
1243     - testbedname: testbed31.
1244     - hostname: s12-t31-sut2.
1245     - IPMI IP: 10.30.50.44
1246     - Host IP: 10.30.51.47
1247     - portnames:
1248         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1249         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1250         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1251         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1252         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1253         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1254         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1255         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1256 - ServerB13 [Server-Type-B2]:
1257     - testbedname: testbed31.
1258     - hostname: s13-t31-tg1.
1259     - IPMI IP: 10.30.50.45
1260     - Host IP: 10.30.51.48
1261     - portnames:
1262         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1263         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1264         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1265         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1266         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1267         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1268         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1269         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1270         - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1271         - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1272         - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1273         - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1274 - ServerB14 [Server-Type-B1]:
1275     - testbedname: testbed32.
1276     - hostname: s14-t32-sut1.
1277     - IPMI IP: 10.30.50.55
1278     - Host IP: 10.30.51.58
1279     - portnames:
1280         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1281         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1282         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1283         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1284         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1285         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1286         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1287         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1288 - ServerB15 [Server-Type-B1]:
1289     - testbedname: testbed32.
1290     - hostname: s15-t32-sut2.
1291     - IPMI IP: 10.30.50.56
1292     - Host IP: 10.30.51.59
1293     - portnames:
1294         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1295         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1296         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1297         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1298         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1299         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1300         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1301         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1302 - ServerB16 [Server-Type-B2]:
1303     - testbedname: testbed32.
1304     - hostname: s16-t32-tg1.
1305     - IPMI IP: 10.30.50.57
1306     - Host IP: 10.30.51.60
1307     - portnames:
1308         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1309         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1310         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1311         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1312         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1313         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1314         - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1315         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1316         - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1317         - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1318         - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1319         - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1320 ```
1321
1322 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1323
1324 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1325
1326 ```
1327 - ServerB22 [Server-Type-B5]:
1328     - testbedname: testbed35.
1329     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1330     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1331     - Host IP: 10.30.51.9
1332     - portnames:
1333         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1334         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1335     - 1GB ports (tbd)
1336 - ServerB23 [Server-Type-B5]:
1337     - testbedname: testbed35.
1338     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1339     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1340     - Host IP: 10.30.51.10
1341     - portnames:
1342         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1343         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1344     - 1GB ports (tbd)
1345 - ServerB24 [Server-Type-B5]:
1346     - testbedname: testbed35.
1347     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1348     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1349     - Host IP: 10.30.51.11
1350     - portnames:
1351         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1352         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1353     - 1GB ports (tbd)
1354 ```
1355
1356 #### 3-Node-Taishan Servers (3n-tsh) PROD
1357
1358 Note: Server19 (TG) is shared between testbed33 & testbed211
1359
1360 ```
1361 - SUT [Server-Type-E21]:
1362     - testbedname: testbed33.
1363     - hostname: s17-t33-sut1.
1364     - IPMI IP: 10.30.50.36
1365     - Host IP: 10.30.51.36
1366     - portnames:
1367         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1368         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1369         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1370         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1371 - SUT [Server-Type-E21]:
1372     - testbedname: testbed33.
1373     - hostname: s18-t33-sut2.
1374     - IPMI IP: 10.30.50.37
1375     - Host IP: 10.30.51.37
1376     - portnames:
1377         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1378         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1379         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1380         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1381 - TG [Server-Type-E31]:
1382     - testbedname: testbed33 and testbed211.
1383     - hostname: s19-t33t211-tg1.
1384     - IPMI IP: 10.30.50.46
1385     - Host IP: 10.30.51.49
1386     - portnames:
1387         - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1388         - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1389         - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1390         - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1391         - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1392         - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1393         - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1394         - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1395         - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1396         - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1397         - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1398         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1399 ```
1400
1401 #### 3-Node-Altra Servers (3n-alt) TBD
1402
1403 ```
1404 - SUT [Server-Type-E23]:
1405     - testbedname: testbed34.
1406     - hostname: s62-t34-sut1.
1407     - IPMI IP: 10.30.50.72
1408     - Host IP: 10.30.51.72
1409     - portnames:
1410         - s62-t34-sut1-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1411         - s62-t34-sut1-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1412         - s62-t34-sut1-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
1413         - s62-t34-sut1-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
1414 - SUT [Server-Type-E23]:
1415     - testbedname: testbed34.
1416     - hostname: s63-t34-sut2.
1417     - IPMI IP: 10.30.50.73
1418     - Host IP: 10.30.51.73
1419     - portnames:
1420         - s63-t34-sut2-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1421         - s63-t34-sut2-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1422         - s63-t34-sut2-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
1423         - s63-t34-sut2-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
1424 - TG [TBD Server-Type]:
1425     - testbedname: testbed34.
1426     - hostname: s64-t34-tg1.
1427     - IPMI IP: 10.30.50.74
1428     - Host IP: 10.30.51.74
1429     - portnames:
1430         - s64-t34-tg1-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1431         - s64-t34-tg1-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1432         - s64-t34-tg1-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
1433         - s64-t34-tg1-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
1434 ```
1435
1436 #### 3-Node-Denverton Servers (3n-dnv) PROD
1437
1438 ```
1439 - ServerB30 [Server-Type-B10]:
1440     - testbednames: testbed35.
1441     - hostname: s30-t35-sut1.
1442     - IPMI IP: 10.30.55.12
1443     - Host IP: 10.32.8.12
1444     - portnames:
1445         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1446         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1447         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1448         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1449 - ServerB31 [Server-Type-B10]:
1450     - testbednames: testbed35.
1451     - hostname: s31-t35-sut2.
1452     - IPMI IP: 10.30.55.13
1453     - Host IP: 10.32.8.13
1454     - portnames:
1455         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1456         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1457         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1458         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1459 ```
1460
1461 ### Per Testbed Wiring
1462
1463 #### 1-Node-Skylake Wiring (1n-skx) PROD
1464
1465 ```
1466 - testbed11:
1467     - ring1 10GE-ports x710-4p10GE:
1468         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1469     - ring2 10GE-ports x710-4p10GE:
1470         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1471     - ring3 10GE-ports x710-4p10GE:
1472         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1473     - ring4 10GE-ports x710-4p10GE:
1474         - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1475     - ring5 100GE-ports e810-2p100GE:
1476         - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1477     - ring6 100GE-ports e810-2p100GE:
1478         - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1479 - testbed12:
1480     - ring1 10GE-ports x710-4p10GE:
1481         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1482     - ring2 10GE-ports x710-4p10GE:
1483         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1484     - ring3 10GE-ports x710-4p10GE:
1485         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1486     - ring4 10GE-ports x710-4p10GE:
1487         - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1488     - ring5 100GE-ports e810-2p100GE:
1489         - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1490     - ring6 100GE-ports e810-2p100GE:
1491         - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1492 ```
1493
1494 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1495
1496 ```
1497 - testbed13:
1498     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1499         - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1500     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1501         - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1502     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1503         - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1504     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1505         - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1506
1507 - testbed14:
1508     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1509         - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1510     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1511         - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1512     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1513         - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1514     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1515         - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1516 ```
1517
1518 #### 2-Node-Skylake Wiring (2n-skx) PROD
1519
1520 ```
1521 - testbed21:
1522     - ring1 10GE-ports x710-4p10GE on SUT:
1523         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1524         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1525     - ring2 10GE-ports x710-4p10GE on SUT:
1526         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1527         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1528     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1529         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1530         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1531     - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1532         - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
1533         - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
1534 - testbed22:
1535     - ring1 10GE-ports x710-4p10GE on SUT:
1536         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1537         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1538     - ring2 10GE-ports x710-4p10GE on SUT:
1539         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1540         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1541     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1542         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1543         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1544     - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1545         - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
1546         - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
1547 - testbed23:
1548     - ring1 10GE-ports x710-4p10GE on SUT:
1549         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1550         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1551     - ring2 10GE-ports x710-4p10GE on SUT:
1552         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1553         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1554     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1555         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1556         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1557     - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1558         - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
1559         - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
1560 - testbed24:
1561     - ring1 10GE-ports x710-4p10GE on SUT:
1562         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1563         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1564     - ring2 10GE-ports x710-4p10GE on SUT:
1565         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1566         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1567     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1568         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1569         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1570     - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1571         - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
1572         - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
1573 ```
1574
1575 #### 2-Node-Denverton Wiring (2n-dnv) PROD
1576
1577 ```
1578 - testbed26:
1579     - ring1 10GE-ports x553 copper port on SUT:
1580         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1581         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1582     - ring2 10GE-ports x553 fiber port on SUT:
1583         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1584         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1585 ```
1586
1587 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1588
1589 ```
1590 - testbed25:
1591     - link1 10GE-port x710-4p10GE on SUT:
1592         - t25-tg1-p1 to t25-sut1-c2/p1.
1593     - link2 10GE-port x710-4p10GE on SUT:
1594         - t25-tg1-p2 to t25-sut1-c2/p2.
1595     - link3 10GE-port x710-4p10GE on SUT:
1596         - t25-tg1-p3 to t25-sut1-c2/p3.
1597     - link4 10GE-port x710-4p10GE on SUT:
1598         - t25-tg1-p4 to t25-sut1-c2/p4.
1599 ```
1600
1601 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1602
1603 ```
1604 - testbed27:
1605     - ring1 10GE-ports x710-4p10GE on SUT:
1606         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1607         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1608     - ring2 10GE-ports x710-4p10GE on SUT:
1609         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1610         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1611     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1612         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1613         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1614     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1615         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1616         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1617     - ring5 100GE-ports e810-2p100GE on SUT:
1618         - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1619         - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1620 - testbed28:
1621     - ring1 10GE-ports x710-4p10GE on SUT:
1622         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1623         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1624     - ring2 10GE-ports x710-4p10GE on SUT:
1625         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1626         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1627     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1628         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1629         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1630     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1631         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1632         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1633     - ring5 100GE-ports e810-2p100GE on SUT:
1634         - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1635         - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1636 - testbed29:
1637     - ring1 10GE-ports x710-4p10GE on SUT:
1638         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1639         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1640     - ring2 10GE-ports x710-4p10GE on SUT:
1641         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1642         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1643     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1644         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1645         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1646     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1647         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1648         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1649     - ring6 100GE-ports e810-2p100GE on SUT:
1650         - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1651         - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1652 ```
1653
1654 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1655
1656 ```
1657 - testbed210:
1658     - ring1 10GE-ports x710-4p10GE on SUT:
1659         - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1660         - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1661     - ring2 10GE-ports x710-4p10GE on SUT:
1662         - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1663         - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1664     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1665         - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1666         - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1667     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1668         - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1669         - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1670 ```
1671
1672 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
1673
1674 ```
1675 - testbed211:
1676     - ring1 10GE-ports x520-2p10GE on SUTs:
1677         - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
1678         - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
1679 ```
1680
1681 #### 3-Node-Skylake Wiring (3n-skx) PROD
1682
1683 ```
1684 - testbed31:
1685     - ring1 10GE-ports x710-4p10GE on SUTs:
1686         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1687         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1688         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1689     - ring2 10GE-ports x710-4p10GE on SUT:
1690         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1691         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1692         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1693     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1694         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1695         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1696         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1697     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1698         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1699         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1700         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1701     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1702         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1703         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1704 - testbed32:
1705     - ring1 10GE-ports x710-4p10GE on SUTs:
1706         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1707         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1708         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1709     - ring2 10GE-ports x710-4p10GE on SUT:
1710         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1711         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1712         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1713     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1714         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1715         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1716         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1717     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1718         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1719         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1720         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1721     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1722         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1723         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1724 ```
1725
1726 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1727
1728 ```
1729 To be completed.
1730 ```
1731
1732 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1733
1734 ```
1735 - testbed33:
1736     - ring1 10GE-ports x520-2p10GE on SUTs:
1737         - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1738         - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1739         - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
1740     - ring2 25GE-ports cx4-2p25GE on SUTs:
1741         - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1742         - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1743         - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
1744 ```
1745
1746 #### 3-Node-Altra Wiring (3n-alt) TBD
1747
1748 ```
1749 - testbed34:
1750     - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
1751         - s64-t34-tg1-cn/p2 - s62-t34-sut1-cn/p2.
1752         - s62-t34-sut1-cn/p1 - s63-t34-sut2-cn/p2.
1753         - s63-t34-sut2-cn/p1 - s64-t34-tg1-cn/p1.
1754     - ring2 100GE-ports ConnectX5-2p100GE on SUTs:
1755         - s64-t34-tg1-ck/p2 - s62-t34-sut1-ck/p2.
1756         - s62-t34-sut1-ck/p1 - s63-t34-sut2-ckp2.
1757         - s63-t34-sut2-ck/p1 - s64-t34-tg1-ck/p1.
1758 ```
1759
1760 #### 3-Node-Denverton Wiring (3n-dnv) PROD
1761
1762 ```
1763 - testbed35:
1764     - ring1 10GE-ports x553 copper port on SUTs:
1765         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1766         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1767         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1768     - ring2 10GE-ports x553 fiber port on SUTs:
1769         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1770         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1771         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1772 ```
1773
1774 ## Inventory
1775
1776 ### Appliances
1777
1778 ```
1779 1. Ixia PerfectStorm One Appliance
1780     - 1 * PS10GE4NG
1781         - Chassis: PS10GE4NG.
1782         - Motherboard: SuperMicro X11DPG-QT.
1783         - Processors: Quad-Core, Intel Processor.
1784         - HW accelerators: FPGA offload.
1785         - RAM Memory: 64GB.
1786         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1787         - Physical Interfaces: 4 * 10GE SFP+.
1788         - Operating System: Native IxOS.
1789 ```
1790
1791 ### Arm Servers
1792
1793 ```
1794 1. Arm Cortex A-72 servers
1795     - 2 * ThunderX2 (VPP Device)
1796         - Chassis: GIGABYTE Rack Mount
1797         - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
1798         - RAM Memory: 16* 16GB DIMM
1799         - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1800     - 1 * ThunderX2 (Performance)
1801         - Chassis: GIGABYTE Rack Mount
1802         - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
1803         - RAM Memory: 4* 32GB RDIMM
1804         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1805     - 2 * Huawei TaiShan 2280.
1806         - Chassis: Huawei TaiShan 2280.
1807         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
1808         - RAM Memory: 8* 16GB DDR4-2400MT/s.
1809         - Disks: 1* 4TB SATA HDD.
1810     - 2 * Ampere Altra
1811         - Chassis: TBD
1812         - Processors: TBD
1813         - RAM Memory: TBD
1814         - Disks: TBD
1815 ```
1816
1817 ### Xeon and Atom Servers
1818
1819 ```
1820 1. Intel Xeon servers:
1821     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1822         - Chassis: SuperMicro SYS-7049GP-TRT.
1823         - Motherboard: SuperMicro X11DPG-QT.
1824         - Processors: 2* Intel Platinum 8180 2.5 GHz.
1825         - RAM Memory: 16* 16GB DDR4-2666MHz.
1826         - Disks: 2* 1.6TB 6G SATA SSD.
1827 2. Intel Atom servers with Rangely processors.
1828     - 3 * Netgate XG-2758-1u
1829         - Chassis: Netgate XG-2758-1u
1830         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1831         - RAM Memory: 16GB ECC
1832         - Disks: 150 GB
1833 ```
1834
1835 ### Network Interface Cards
1836
1837 ```
1838 1. 10GE NICs
1839     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1840     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1841     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1842 2. 25GE NICs
1843     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1844 3. 40GE NICs
1845     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1846 4. 100GE NICs
1847     - 4 * mcx556a-edat NICs (not on site yet, in transit)
1848 ```
1849
1850 ### Pluggables and Cables
1851
1852 Pluggables:
1853
1854 ```
1855 1. 10GE SFP+
1856     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1857     - 80 * 10G SR optic (generic, "Intel" compatible branded)
1858 2. 25GE SFP28
1859     - None
1860 3. 40GE QSFP+
1861     - None
1862 4. 100GE
1863     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1864 ```
1865
1866 Standalone cables:
1867
1868 ```
1869 1. 10GE
1870     - None
1871 2. 25GE
1872     - None
1873 3. 40GE QSFP+
1874     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
1875 4. 100GE
1876     - None
1877 ```
1878
1879 ### Other Parts