1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
15 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
16 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
17 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
19 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
20 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
21 1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
22 1. [Server Management](#server-management)
23 1. [Requirements](#requirements)
24 1. [Addressing](#addressing)
25 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
26 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
27 1. [Server Specifications](#server-specifications)
28 1. [Server Types](#server-types)
29 1. [Naming Convention](#naming-convention)
30 1. [Testbeds Configuration](#testbeds-configuration)
31 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
32 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
33 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
34 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
35 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
36 1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
37 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
38 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
39 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
40 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
41 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
42 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
43 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
44 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
45 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
46 1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
47 1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
48 1. [Per Testbed Wiring](#per-testbed-wiring)
49 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
50 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
51 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
52 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
53 1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
54 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
55 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
56 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
57 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
58 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
59 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
60 1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
61 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
62 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
63 1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
64 1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
65 1. [Inventory](#inventory)
66 1. [Appliances](#appliances)
67 1. [Arm Servers](#arm-servers)
68 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
69 1. [Network Interface Cards](#network-interface-cards)
70 1. [Pluggables and Cables](#pluggables-and-cables)
71 1. [Other Parts](#other-parts)
75 This note includes specification of the physical testbed infrastructure
76 hosted by LFN FD.io CSIT project.
83 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx #snr
84 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0 0 0 0
85 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0 0 0
86 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 0
87 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0 0 0
88 5. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 0 0 2 0 0 0 0
89 6. 2-Node-Skylake perf skx skx 3 3 3 0 6 0 0 0 0 0 0 0 0 0 0
90 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0 0 0
91 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0 0 0
92 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0 0 0
93 10. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 0 1 0 0 0 0 0 0
94 11. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0
95 12. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 0 0
96 13. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 0 0
97 14. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 0 0 0
98 15. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 0 0 2 0 0 1 0
99 16. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 0 0
100 17. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 0 0
101 18. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 0 0 6 0
102 19. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 0 0 .5 2
103 Totals: 34 44 21.5 4 17 1 2 3 3 2 4 7 2 15.5 2
106 ### 1-Node-Skylake Xeon Intel (1n-skx)
108 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
109 ports connected back-to-back ([Server Types](#server-types)).
110 Used for FD.io VPP_Device functional driver tests.
112 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
114 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
115 ports connected back-to-back ([Server Types](#server-types)).
116 Used for FD.io VPP_Device functional driver tests.
118 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
120 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
121 NIC ports connected back-to-back ([Server Types](#server-types)).
123 Used for FD.io VPP_Device functional driver tests.
125 ### 2-Node-Skylake Xeon Intel (2n-skx)
127 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
128 (Server-Type-B2) connected in a 2-node circular topology
129 ([Server Types](#server-types)).
130 Used for FD.io performance tests.
132 ### 2-Node-Denverton Atom Intel (2n-dnv)
134 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
135 TG (Server-Type-B2) connected in a 2-node circular topology
136 ([Server Types](#server-types)).
137 Used for FD.io performance tests.
139 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
141 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
142 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
143 circular topology ([Server Types](#server-types)).
144 Used for FD.io TCP/IP and HTTP performance tests.
146 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
148 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
149 one TG (Server-Type-C3) connected in a 2-node circular topology
150 ([Server Types](#server-types)).
151 Used for FD.io performance tests.
153 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
155 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
156 one TG (Server-Type-D2) connected in a 2-node circular topology
157 ([Server Types](#server-types)).
158 Used for FD.io performance tests.
160 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
162 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
163 one TG (Server-Type-E31) connected in a 2-node circular topology
164 ([Server Types](#server-types)).
165 Used for FD.io performance tests.
167 ### 2-Node-Icelake Xeon Intel (2n-icx)
169 Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
170 one TG (Server-Type-F2) connected in a 2-node circular topology
171 ([Server Types](#server-types)).
172 Used for FD.io performance tests.
174 ### 3-Node-Haswell Xeon Intel (3n-hsw)
176 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
177 TG (Server-Type-A2) connected in a 3-node circular topology
178 ([Server Types](#server-types)).
179 Used for FD.io performance tests.
181 ### 3-Node-Skylake Xeon Intel (3n-skx)
183 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
184 TG (Server-Type-B2) connected in a 3-node circular topology.
185 Used for FD.io performance tests.
187 ### 3-Node-Rangeley Atom Testbeds
189 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
190 TG (Server-Type-2) connected in a 3-node circular topology
191 ([Server Types](#server-types)).
192 Used for FD.io performance tests.
194 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
196 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
197 TG (Server-Type-E31) connected in a 3-node circular topology
198 ([Server Types](#server-types)).
199 Used for FD.io performance tests.
201 ### 3-Node-Altra Arm Ampere (3n-alt)
203 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
204 TG (Server-Type-F4) connected in a 3-node circular topology
205 ([Server Types](#server-types)).
206 Used for FD.io performance tests.
208 ### 3-Node-Icelake Xeon Intel (3n-icx)
210 Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
211 TG (Server-Type-F3) connected in a 3-node circular topology
212 ([Server Types](#server-types)).
213 Used for FD.io performance tests.
215 ### 3-Node-SnowRidge Atom Intel (3n-snr)
217 Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
218 TG (Server-Type-F4) connected in a 3-node circular topology
219 ([Server Types](#server-types)).
220 Used for FD.io performance tests.
227 For management purposes, each server must have following two ports
228 connected to the management network:
232 - IPMI - Intelligent Platform Management Interface.
233 - Required for access to embedded server management with WebUI, CLI,
234 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
235 - 1GE/10GE/40GE management port
236 - hostOS management port for general system management.
241 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
242 Management port, which are connected to two different VLANs.
246 - Subnet: 10.30.50.0/24
247 - Gateway: 10.30.50.1
248 - Broadcast: 10.30.50.255
249 - DNS1: 199.204.44.24
250 - DNS2: 199.204.47.54
252 - Subnet: 10.30.51.0/24
253 - Gateway: 10.30.51.1
254 - Broadcast: 10.30.51.255
255 - DNS1: 199.204.44.24
256 - DNS2: 199.204.47.54
259 To access these hosts, VPN connection is required.
261 ### LOM (IPMI) VLAN IP Addresses
264 ------------ | -------
267 10.30.50.2 | LF Reserved
268 10.30.50.3 | LF Reserved
269 10.30.50.4 | LF Reserved
270 10.30.50.5 | LF Reserved
271 10.30.50.6 | LF Reserved
272 10.30.50.7 | LF Reserved
273 10.30.50.8 | LF Reserved
274 10.30.50.9 | LF Reserved
275 10.30.50.10 | LF Reserved
276 10.30.50.11 | LF Reserved
277 10.30.50.12 | LF Reserved
278 10.30.50.13 | LF Reserved
279 10.30.50.14 | LF Reserved
280 10.30.50.15 | LF Reserved
281 10.30.50.16 | s16-nomad
282 10.30.50.17 | s17-nomad
283 10.30.50.18 | s18-nomad
284 10.30.50.19 | s19-nomad
285 10.30.50.20 | s20-nomad
286 10.30.50.21 | s21-nomad
287 10.30.50.22 | s22-nomad
288 10.30.50.23 | s23-nomad
289 10.30.50.24 | s24-nomad
290 10.30.50.25 | s25-nomad
291 10.30.50.26 | s26-nomad
292 10.30.50.36 | s17-t33-sut1
293 10.30.50.37 | s18-t33-sut2
294 10.30.50.38 | fdio-marvell-dev
295 10.30.50.39 | s53-nomad
296 10.30.50.40 | s54-nomad
297 10.30.50.41 | s3-t21-sut1
298 10.30.50.42 | s4-t21-tg1
299 10.30.50.43 | s11-t31-sut1
300 10.30.50.44 | s12-t31-sut2
301 10.30.50.45 | s13-t31-tg1
302 10.30.50.46 | s19-t33t211-tg1
303 10.30.50.47 | s1-t11-sut1
304 10.30.50.48 | s2-t12-sut1
305 10.30.50.49 | s5-t22-sut1
306 10.30.50.50 | s6-t22-tg1
307 10.30.50.51 | s7-t23-sut1
308 10.30.50.52 | s8-t23-tg1
309 10.30.50.53 | s9-t24-sut1
310 10.30.50.54 | s10-t24-tg1
311 10.30.50.55 | s14-t32-sut1
312 10.30.50.56 | s15-t32-sut2
313 10.30.50.57 | s16-t32-tg1
314 10.30.50.58 | s25-t25-sut1
315 10.30.50.59 | s26-t25-tg1
316 10.30.50.65 | s52-nomad
317 10.30.50.66 | s51-nomad
318 10.30.50.67 | s49-nomad
319 10.30.50.68 | s50-nomad
320 10.30.50.69 | s27-t211-sut1
321 10.30.50.70 | s55-t13-sut1
322 10.30.50.71 | s56-t14-sut1
323 10.30.50.72 | s62-t34-sut1
324 10.30.50.73 | s63-t34-sut2
325 10.30.50.74 | s64-t34-tg1
326 10.30.50.75 | s65-t37-sut1
327 10.30.50.76 | s66-t37-sut2
328 10.30.50.77 | s67-t37-tg1
329 10.30.50.78 | s78-t38-sut1
330 10.30.50.79 | s79-t38-sut2
331 10.30.50.80 | s80-t38-tg1
332 10.30.50.81 | s71-t212-sut1
333 10.30.50.82 | s72-t212-tg1
334 10.30.50.83 | s83-t213-sut1
335 10.30.50.84 | s84-t213-tg1
336 10.30.50.85 | s85-t214-sut1
337 10.30.50.86 | s86-t214-tg1
338 10.30.50.87 | s87-t215-sut1
339 10.30.50.88 | s88-t215-tg1
340 10.30.50.89 | s89-t39t310-tg1
341 10.30.50.90 | s90-t311t312-tg1
342 10.30.50.91 | s58-nomad
343 10.30.50.92 | s59-nomad
344 10.30.50.93 | s93-t39-sut1
345 10.30.50.94 | s94-t39-sut2
346 10.30.50.255 | Broadcast
349 10.30.55.10 | s28-t26t35-tg1
350 10.30.55.11 | s29-t26-sut1
351 10.30.55.12 | s30-t35-sut1
352 10.30.55.13 | s31-t35-sut2
353 10.30.55.18 | s33-t27-sut1
354 10.30.55.19 | s34-t27-tg1
355 10.30.55.20 | s35-t28-sut1
356 10.30.55.21 | s36-t28-tg1
357 10.30.55.22 | s37-t29-sut1
358 10.30.55.23 | s38-t29-tg1
359 10.30.55.24 | s60-t210-sut1
360 10.30.55.25 | s61-t210-tg1
361 10.30.55.255 | Broadcast
363 ### Management VLAN IP Addresses
366 -------------| -------
369 10.30.51.2 | LF Reserved
370 10.30.51.3 | LF Reserved
371 10.30.51.4 | LF Reserved
372 10.30.51.5 | LF Reserved
373 10.30.51.6 | LF Reserved
374 10.30.51.7 | LF Reserved
375 10.30.51.8 | LF Reserved
376 10.30.51.15 | LF Reserved
377 10.30.51.16 | s16-nomad
378 10.30.51.17 | s17-nomad
379 10.30.51.18 | s18-nomad
380 10.30.51.19 | s19-nomad
381 10.30.51.20 | s20-nomad
382 10.30.51.21 | s21-nomad
383 10.30.51.22 | s22-nomad
384 10.30.51.23 | s23-nomad
385 10.30.51.24 | s24-nomad
386 10.30.51.25 | s25-nomad
387 10.30.51.26 | s26-nomad
388 10.30.51.36 | s17-t33-sut1
389 10.30.51.37 | s18-t33-sut2
390 10.30.51.38 | fdio-marvell-dev
391 10.30.51.39 | s53-nomad
392 10.30.51.40 | s54-nomad
393 10.30.51.44 | s3-t21-sut1
394 10.30.51.45 | s4-t21-tg1
395 10.30.51.46 | s11-t31-sut1
396 10.30.51.47 | s12-t31-sut2
397 10.30.51.48 | s13-t31-tg1
398 10.30.51.49 | s19-t33t211-tg1
399 10.30.51.50 | s1-t11-sut1
400 10.30.51.51 | s2-t12-sut1
401 10.30.51.52 | s5-t22-sut1
402 10.30.51.53 | s6-t22-tg1
403 10.30.51.54 | s7-t23-sut1
404 10.30.51.55 | s8-t23-tg1
405 10.30.51.56 | s9-t24-sut1
406 10.30.51.57 | s10-t24-tg1
407 10.30.51.58 | s14-t32-sut1
408 10.30.51.59 | s15-t32-sut2
409 10.30.51.60 | s16-t32-tg1
410 10.30.51.61 | s25-t25-sut1
411 10.30.51.62 | s26-t25-tg1
412 10.30.51.65 | s52-nomad
413 10.30.51.66 | s51-nomad
414 10.30.51.67 | s49-nomad
415 10.30.51.68 | s50-nomad
416 10.30.51.69 | s27-t211-sut1
417 10.30.51.70 | s55-t13-sut1
418 10.30.51.71 | s56-t14-sut1
419 10.30.51.72 | s62-t34-sut1
420 10.30.51.73 | s63-t34-sut2
421 10.30.51.74 | s64-t34-tg1
422 10.30.51.75 | s65-t37-sut1
423 10.30.51.76 | s66-t37-sut2
424 10.30.51.77 | s67-t37-tg1
425 10.30.51.78 | s78-t38-sut1
426 10.30.51.79 | s79-t38-sut2
427 10.30.51.80 | s80-t38-tg1
428 10.30.51.81 | s71-t212-sut1
429 10.30.51.82 | s72-t212-tg1
430 10.30.51.83 | s83-t213-sut1
431 10.30.51.84 | s84-t213-tg1
432 10.30.51.85 | s85-t214-sut1
433 10.30.51.86 | s86-t214-tg1
434 10.30.51.87 | s87-t215-sut1
435 10.30.51.88 | s88-t215-tg1
436 10.30.51.89 | s89-t39t310-tg1
437 10.30.51.90 | s90-t311t312-tg1
438 10.30.51.91 | s58-nomad
439 10.30.51.92 | s59-nomad
440 10.30.51.93 | s93-t39-sut1
441 10.30.51.94 | s94-t39-sut2
442 10.30.51.255 | Broadcast
445 10.32.8.10 | s28-t26t35-tg1
446 10.32.8.11 | s29-t26-sut1
447 10.32.8.12 | s30-t35-sut1
448 10.32.8.13 | s31-t35-sut2
449 10.32.8.18 | s33-t27-sut1
450 10.32.8.19 | s34-t27-tg1
451 10.32.8.20 | s35-t28-sut1
452 10.32.8.21 | s36-t28-tg1
453 10.32.8.22 | s37-t29-sut1
454 10.32.8.23 | s38-t29-tg1
455 10.32.8.24 | s60-t210-sut1
456 10.32.8.25 | s61-t210-tg1
457 10.32.8.255 | Broadcast
459 ## Server Specifications
463 FD.io CSIT lab contains following server types:
465 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
466 - Quantity: 6 servers.
467 - Physical connectivity:
468 - CIMC and host management ports.
469 - NIC ports connected in 3-node topologies.
470 - Main HW configuration:
471 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
472 - Processors: 2* E5-2699v3 2.3 GHz.
473 - RAM Memory: 16* 32GB DDR4-2133MHz.
474 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
475 - NICs configuration:
476 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
480 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
484 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
485 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
486 - Quantity: 3 servers.
487 - Physical connectivity:
488 - CIMC and host management ports.
489 - NIC ports connected in 3-node topologies.
490 - Main HW configuration:
491 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
492 - Processors: 2* E5-2699v3 2.3 GHz.
493 - RAM Memory: 16* 32GB DDR4-2133MHz.
494 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
495 - NICs configuration:
496 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
500 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
505 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
506 - Quantity: 3 servers.
507 - Physical connectivity:
508 - CIMC and host management ports.
509 - no NIC ports, standalone setup.
510 - Main HW configuration:
511 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
512 - Processors: 2* E5-2699v3 2.3 GHz.
513 - RAM Memory: 16* 32GB DDR4-2133MHz.
514 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
515 - NICs configuration:
516 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
518 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
521 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
523 - Physical connectivity:
524 - IPMI and host management ports.
525 - NIC ports connected into 2-node and 3-node topologies.
526 - Main HW configuration:
527 - Chassis: SuperMicro SYS-7049GP-TRT.
528 - Motherboard: SuperMicro X11DPG-QT.
529 - Processors: 2* Intel Platinum 8180 2.5 GHz.
530 - RAM Memory: 16* 16GB DDR4-2666MHz.
531 - Disks: 2* 1.6TB 6G SATA SSD.
532 - NICs configuration:
533 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
534 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
535 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
536 - PCIe Slot9 5e:00.xx: empty.
537 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
538 - PCIe Slot6 86:00.xx: empty.
539 - PCIe Slot8 af:00.xx: empty.
540 - PCIe Slot10 d8:00.xx: empty.
541 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
543 - Physical connectivity:
544 - IPMI and host management ports.
545 - NIC ports connected into 2-node and 3-node topologies.
546 - Main HW configuration:
547 - Chassis: SuperMicro SYS-7049GP-TRT.
548 - Motherboard: SuperMicro X11DPG-QT.
549 - Processors: 2* Intel Platinum 8180 2.5 GHz.
550 - RAM Memory: 16* 16GB DDR4-2666MHz.
551 - Disks: 2* 1.6TB 6G SATA SSD.
552 - NICs configuration:
553 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
554 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
555 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
556 - PCIe Slot9 5e:00.xx: empty.
557 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
558 - PCIe Slot6 86:00.xx: empty.
559 - PCIe Slot8 af:00.xx: empty.
560 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
561 6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
562 - Quantity: TBD based on testbed allocation.
563 - Physical connectivity:
564 - Management: serial Port (usb) for console
565 - NIC ports connected into 2-node.
566 - Main HW configuration:
567 - Chassis: Netgate XG-2758-1u
568 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
569 - RAM Memory: 16GB ECC
571 - NICs configuration:
572 - 2x 10Gb Intel 82599ES
574 7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
576 - Physical connectivity:
577 - IPMI and host management ports.
578 - NIC ports connected into 1-node topologies.
579 - Main HW configuration:
580 - Chassis: SuperMicro SYS-7049GP-TRT.
581 - Motherboard: SuperMicro X11DPG-QT.
582 - Processors: 2* Intel Platinum 8180 2.5 GHz.
583 - RAM Memory: 16* 16GB DDR4-2666MHz.
584 - Disks: 2* 1.6TB 6G SATA SSD.
585 - NICs configuration:
586 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
587 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
588 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
589 - PCIe Slot9 5e:00.xx: empty.
590 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
591 - PCIe Slot6 86:00.xx: empty.
592 - PCIe Slot8 af:00.xx: empty.
593 - PCIe Slot10 d8:00.xx: empty.
594 8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
596 - Physical connectivity:
597 - Host management interface: 10/100/1000-BaseT.
598 - 8-port 10GE SFP+ integrated NIC.
599 - Main HW configuration:
600 - Chassis: PS10GE4NG.
601 - Motherboard: SuperMicro X11DPG-QT.
602 - Processors: Quad-Core, Intel Processor.
603 - HW accelerators: FPGA offload.
605 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
606 - Physical Interfaces: 4 * 10GE SFP+.
607 - Operating System: Native IxOS.
608 - Interface configuration:
613 9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
615 - Physical connectivity:
616 - IPMI and host management ports.
618 - Main HW configuration:
619 - Chassis: SuperMicro SYS-7049GP-TRT.
620 - Motherboard: SuperMicro X11DPG-QT.
621 - Processors: 2* Intel Platinum 8180 2.5 GHz.
622 - RAM Memory: 16* 16GB DDR4-2666MHz.
623 - Disks: 2* 1.6TB 6G SATA SSD.
624 - NICs configuration:
625 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
626 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
627 - PCIe Slot4 3b:00.xx: empty.
628 - PCIe Slot9 5e:00.xx: empty.
629 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
630 - PCIe Slot6 86:00.xx: empty.
631 - PCIe Slot8 af:00.xx: empty.
632 - PCIe Slot10 d8:00.xx: empty.
633 10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
635 - Physical connectivity:
636 - IPMI and host management ports.
638 - Main HW configuration:
639 - Chassis: SuperMicro SYS-E300-9A
640 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
641 - RAM Memory: 32GB ECC
643 - NICs configuration:
644 - 2x 10Gb Intel x553 fiber ports
645 - 2x 10Gb Intel x553 copper ports
646 - 4x 1GB Intel I350 ports
647 11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
649 - Physical connectivity:
650 - IPMI and host management ports.
651 - NIC ports connected into 1-node testbed topologies.
652 - Main HW configuration:
653 - Chassis: SuperMicro SYS-7049GP-TRT.
654 - Motherboard: SuperMicro X11DPG-QT.
655 - Processors: 2* Intel Platinum 8280 2.7 GHz.
656 - RAM Memory: 12* 16GB DDR4-2933.
657 - Disks: 2* 1.92TB SATA SSD.
658 - NICs configuration:
659 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
660 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
661 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
662 - PCIe Slot9 5e:00.xx: empty.
663 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
664 - PCIe Slot6 86:00.xx: empty.
665 - PCIe Slot8 af:00.xx: empty.
666 - PCIe Slot10 d8:00.xx: empty.
667 12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
669 - Physical connectivity:
670 - IPMI and host management ports.
671 - NIC ports connected into 2-node testbed topologies.
672 - Main HW configuration:
673 - Chassis: SuperMicro SYS-7049GP-TRT.
674 - Motherboard: SuperMicro X11DPG-QT.
675 - Processors: 2* Intel Gold 6252N 2.3 GHz.
676 - RAM Memory: 12* 16GB DDR4-2933.
677 - Disks: 2* 1.92TB SATA SSD.
678 - NICs configuration:
679 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
680 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
681 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
682 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
683 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
684 - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
685 - PCIe Slot8 af:00.xx: empty.
686 - PCIe Slot10 d8:00.xx: empty.
687 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
689 - Physical connectivity:
690 - IPMI and host management ports.
691 - NIC ports connected into 2-node testbed topologies.
692 - Main HW configuration:
693 - Chassis: SuperMicro SYS-7049GP-TRT.
694 - Motherboard: SuperMicro X11DPG-QT.
695 - Processors: 2* Intel Platinum 8280 2.7 GHz.
696 - RAM Memory: 12* 16GB DDR4-2933.
697 - Disks: 2* 1.92TB SATA SSD.
698 - NICs configuration:
699 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
700 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
701 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
702 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
703 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
704 - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
705 - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
706 - PCIe Slot10 d8:00.xx: empty.
707 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
709 - Physical connectivity:
710 - IPMI and host management ports.
711 - no NIC ports, standalone setup.
712 - Main HW configuration:
713 - Chassis: SuperMicro 1029P-WTRT.
714 - Motherboard: SuperMicro X11DDW-NT.
715 - Processors: 2* Intel Platinum 8280 2.7 GHz.
716 - RAM Memory: 12* 16GB DDR4-2933.
717 - Disks: 4* 1.92TB SATA SSD.
718 - NICs configuration:
723 15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
725 - Physical connectivity:
726 - IPMI and host management ports.
727 - NIC ports connected into 2-node testbed topologies.
728 - Main HW configuration:
729 - Chassis: SuperMicro AS-1114S-WTRT
730 - Processors: 1* AMD EPYC 7532 2.4 GHz.
731 - RAM Memory: 8* 32GB DDR4-2933.
732 - Disks: 1* 1TB SATA SSD.
733 - NICs configuration:
734 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
735 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
736 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
737 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
738 16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
740 - Physical connectivity:
741 - IPMI and host management ports.
742 - NIC ports connected into 2-node testbed topologies.
743 - Main HW configuration:
744 - Chassis: SuperMicro AS-1114S-WTRT
745 - Processors: 1* AMD EPYC 7532 2.4 GHz.
746 - RAM Memory: 8* 32GB DDR4-2933.
747 - Disks: 1* 1TB SATA SSD.
748 - NICs configuration:
749 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
750 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
751 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
752 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
753 17. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
755 - Physical connectivity:
756 - IPMI and host management ports.
757 - NIC ports connected into 1-node topologies.
758 - Main HW configuration:
759 - Chassis: GIGABYTE Rack Mount
760 - Motherboard: MT91-FS4-00
761 - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
762 - RAM Memory: 16 * 16GB DIMM
763 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
764 - NICs configuration:
766 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
767 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
769 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
770 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
771 18. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
773 - Physical connectivity:
774 - IPMI(?) and host management ports.
775 - NIC ports connected into 3-node topology.
776 - Main HW configuration:
777 - Chassis: Huawei TaiShan 2280.
778 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
779 - RAM Memory: 8* 16GB DDR4-2400MT/s
780 - Disks: 1* 4TB SATA HDD
781 - NICs configuration:
782 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
783 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
784 19. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
786 - Physical connectivity:
787 - IPMI and host management ports.
788 - NIC ports connected into 2-node topologies.
789 - Main HW configuration:
790 - Chassis: Gigabyte R181-T90 1U
791 - Motherboard: MT91-FS1
792 - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
793 - RAM Memory: 4* 32GB RDIMM
794 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
795 - NICs configuration:
799 - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
800 20. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
802 - Physical connectivity:
803 - IPMI and host management ports.
804 - NIC ports connected into 3-node topologies.
805 - Main HW configuration:
806 - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
807 - Motherboard: Mt.Jade Motherboard
808 - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
809 - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
810 - RAM Memory: 16* 8GB DDR4-3200MT/s
811 - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
812 - NICs configuration:
814 - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
817 21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
819 - Physical connectivity:
820 - IPMI and host management ports.
821 - Main HW configuration:
822 - Chassis: Gigabyte R152-P30-00 1U
823 - Motherboard: MP32-AR1-00
824 - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
825 - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
826 - RAM Memory: 12* 16GB DDR4-3200MT/s
827 - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
828 22. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
830 - Physical connectivity:
831 - IPMI and host management ports.
832 - NIC ports connected into 2-node and 3-node topologies.
833 - Main HW configuration:
834 - Chassis: SuperMicro SYS-7049GP-TRT.
835 - Motherboard: SuperMicro X11DPG-QT.
836 - Processors: 2* Intel Platinum 8180 2.5 GHz.
837 - RAM Memory: 16* 16GB DDR4-2666MHz.
838 - Disks: 2* 1.6TB 6G SATA SSD.
839 - NICs configuration:
840 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
841 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
842 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
843 - PCIe Slot9 5e:00.xx: empty.
844 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
845 - PCIe Slot6 86:00.xx: empty.
846 - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
847 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
848 23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
850 - Physical connectivity:
851 - IPMI and host management ports.
852 - NIC ports connected into 2-node or 3-node testbed topologies.
853 - Main HW configuration:
854 - Chassis: SuperMicro SYS-740GP-TNRT.
855 - Motherboard: Super X12DPG-QT6.
856 - Processors: 2* Intel Platinum 8358 2.6 GHz.
857 - RAM Memory: 16* 16GB DDR4-3200.
858 - Disks: 2* 960GB SATA SSD.
859 - NICs configuration:
860 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
861 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
862 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
863 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
864 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
865 - PCIe Slot6 86:00.xx: empty.
866 - PCIe Slot8 af:00.xx: empty.
867 - PCIe Slot10 d8:00.xx: empty.
868 24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
870 - Physical connectivity:
871 - IPMI and host management ports.
872 - NIC ports connected into 2-node testbed topologies.
873 - Main HW configuration:
874 - Chassis: SuperMicro SYS-740GP-TNRT.
875 - Motherboard: Super X12DPG-QT6.
876 - Processors: 2* Intel Platinum 8358 2.6 GHz.
877 - RAM Memory: 16* 16GB DDR4-3200.
878 - Disks: 2* 960GB SATA SSD.
879 - NICs configuration:
880 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
881 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
882 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
883 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
884 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
885 - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
886 - PCIe Slot8 af:00.xx: empty.
887 - PCIe Slot10 d8:00.xx: empty.
888 25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
890 - Physical connectivity:
891 - IPMI and host management ports.
892 - NIC ports connected into 3-node testbed topologies.
893 - Main HW configuration:
894 - Chassis: SuperMicro SYS-740GP-TNRT.
895 - Motherboard: Super X12DPG-QT6.
896 - Processors: 2* Intel Platinum 8358 2.6 GHz.
897 - RAM Memory: 16* 16GB DDR4-3200.
898 - Disks: 2* 960GB SATA SSD.
899 - NICs configuration:
900 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
901 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
902 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
903 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
904 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
905 - PCIe Slot6 86:00.xx: empty.
906 - PCIe Slot8 af:00.xx: empty.
907 - PCIe Slot10 d8:00.xx: empty.
908 26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
910 - Physical connectivity:
911 - IPMI and host management ports.
912 - NIC ports connected into 2-node and/or 3-node testbed topologies.
913 - Main HW configuration:
914 - Chassis: SuperMicro SYS-740GP-TNRT.
915 - Motherboard: Super X12DPG-QT6.
916 - Processors: 2* Intel Platinum 8358 2.6 GHz.
917 - RAM Memory: 16* 16GB DDR4-3200.
918 - Disks: 2* 960GB SATA SSD.
919 - NICs configuration:
920 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
921 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
922 - PCIe Slot4 3b:00.xx: empty.
923 - PCIe Slot9 5e:00.xx: empty.
924 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
925 - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
926 - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
927 - PCIe Slot10 d8:00.xx: empty.
928 27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
930 - Physical connectivity:
931 - IPMI and host management ports.
932 - NIC ports connected into 3-node testbed topology.
933 - Main HW configuration:
934 - Chassis: Intel JACOBSVILLE SDP.
935 - Motherboard: Intel JACOBSVILLE E63448-400.
936 - Processors: 1* Intel Atom P5362B 2.2 GHz.
937 - RAM Memory: 2* 16GB DDR4-2933.
938 - Disks: ?* ? SATA SSD.
939 - NICs configuration:
940 - Numa0: (x16, PCIe3.0 lane)
941 - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
944 ### Naming Convention
946 Following naming convention is used within this page to specify physical
947 connectivity and wiring across defined CSIT testbeds:
950 - testbedname: testbedN.
952 - traffic-generator: tN-tgW.
953 - system-under-testX: tN-sutX.
958 - N - testbed number.
959 - tgW - server acts as traffic-generator with W index.
960 - sutX - server acts as system-under-test with X index.
961 - Y - PCIe slot number denoting a NIC card number within the host.
962 - Z - port number on the NIC card.
965 ## Testbeds Configuration
967 ### Per Testbed Server Allocation and Naming
969 #### 1-Node-Skylake Servers (1n-skx) PROD
972 - SUT [Server-Type-B6]:
973 - testbedname: testbed11.
974 - hostname: s1-t11-sut1.
975 - IPMI IP: 10.30.50.47
976 - Host IP: 10.30.51.50
978 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
979 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
980 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
981 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
982 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
983 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
984 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
985 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
986 - SUT [Server-Type-B6]:
987 - testbedname: testbed12.
988 - hostname: s2-t12-sut1.
989 - IPMI IP: 10.30.50.48
990 - Host IP: 10.30.51.51
992 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
993 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
994 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
995 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
996 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
997 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
998 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
999 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
1002 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
1005 - SUT [Server-Type-E11]:
1006 - testbedname: testbed13
1007 - hostname: s55-t13-sut1
1008 - IPMI IP: 10.30.50.70
1009 - Host IP: 10.30.51.70
1011 - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1012 - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1013 - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1014 - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1015 - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1016 - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1017 - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1018 - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1019 - SUT [Server-Type-E11]:
1020 - testbedname: testbed14
1021 - hostname: s56-t14-sut1
1022 - IPMI IP: 10.30.50.71
1023 - Host IP: 10.30.51.71
1025 - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1026 - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1027 - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1028 - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1029 - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1030 - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1031 - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1032 - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1035 #### 1-Node-Cascadelake Servers (1n-clx) PROD
1038 - SUT [Server-Type-C1]:
1039 - testbedname: testbed11.
1040 - hostname: s32-t14-sut1.
1041 - IPMI IP: 10.30.55.17
1042 - Host IP: 10.32.8.17
1044 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1045 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1046 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1047 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1048 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
1049 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
1050 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
1051 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
1054 #### 2-Node-Skylake Servers (2n-skx) PROD
1057 - SUT [Server-Type-B1]:
1058 - testbedname: testbed21.
1059 - hostname: s3-t21-sut1.
1060 - IPMI IP: 10.30.50.41
1061 - Host IP: 10.30.51.44
1063 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1064 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1065 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1066 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1067 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1068 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1069 - TG [Server-Type-B2]:
1070 - testbedname: testbed21.
1071 - hostname: s4-t21-tg1.
1072 - IPMI IP: 10.30.50.42
1073 - Host IP: 10.30.51.45
1075 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1076 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1077 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1078 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1079 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1080 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1081 - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1082 - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1083 - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1084 - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1085 - SUT [Server-Type-B1]:
1086 - testbedname: testbed22.
1087 - hostname: s5-t22-sut1.
1088 - IPMI IP: 10.30.50.49
1089 - Host IP: 10.30.51.52
1091 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1092 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1093 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1094 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1095 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1096 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1097 - TG [Server-Type-B2]:
1098 - testbedname: testbed22.
1099 - hostname: s6-t22-tg1.
1100 - IPMI IP: 10.30.50.50
1101 - Host IP: 10.30.51.53
1103 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1104 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1105 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1106 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1107 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1108 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1109 - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1110 - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1111 - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1112 - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1113 - SUT [Server-Type-B1]:
1114 - testbedname: testbed23.
1115 - hostname: s7-t23-sut1.
1116 - IPMI IP: 10.30.50.51
1117 - Host IP: 10.30.51.54
1119 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1120 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1121 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1122 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1123 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1124 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1125 - TG [Server-Type-B2]:
1126 - testbedname: testbed23.
1127 - hostname: s8-t23-tg1.
1128 - IPMI IP: 10.30.50.52
1129 - Host IP: 10.30.51.55
1131 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1132 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1133 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1134 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1135 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1136 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1137 - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1138 - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1139 - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1140 - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1141 - SUT [Server-Type-B1]:
1142 - testbedname: testbed24.
1143 - hostname: s9-t24-sut1.
1144 - IPMI IP: 10.30.50.53
1145 - Host IP: 10.30.51.56
1147 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1148 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1149 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1150 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1151 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1152 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1153 - TG [Server-Type-B2]:
1154 - testbedname: testbed24.
1155 - hostname: s10-t24-tg1.
1156 - IPMI IP: 10.30.50.54
1157 - Host IP: 10.30.51.57
1159 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1160 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1161 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1162 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1163 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1164 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1165 - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1166 - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1167 - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1168 - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1171 #### 2-Node-Denverton Servers (2n-dnv) PROD
1173 Note: ServerB28 (TG) is shared between testbed26 & testbed35
1176 - TG [Server-Type-B2]:
1177 - testbednames: testbed26 and testbed35.
1178 - hostname: s28-t26t35-tg1.
1179 - IPMI IP: 10.30.55.10
1180 - Host IP: 10.32.8.10
1182 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
1183 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
1184 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
1185 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
1186 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
1187 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
1188 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
1189 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
1190 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
1191 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
1192 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
1193 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
1194 - SUT [Server-Type-B10]:
1195 - testbednames: testbed26.
1196 - hostname: s29-t26-sut1.
1197 - IPMI IP: 10.30.55.11
1198 - Host IP: 10.32.8.11
1200 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
1201 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
1202 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
1203 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
1206 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
1209 - SUT [Server-Type-B8]:
1210 - testbedname: testbed25.
1211 - hostname: s25-t25-sut1.
1212 - IPMI IP: 10.30.50.58
1213 - Host IP: 10.30.51.61
1215 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1216 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1217 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1218 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1219 - TG [Server-Type-B7]:
1220 - testbedname: testbed25.
1221 - hostname: s26-t25-tg1.
1222 - IPMI IP: 10.30.50.59
1223 - Host IP: 10.30.51.62
1225 - s26-t25-tg1-p1 - 10GE-port1.
1226 - s26-t25-tg1-p2 - 10GE-port2.
1227 - s26-t25-tg1-p3 - 10GE-port3.
1228 - s26-t25-tg1-p4 - 10GE-port4.
1231 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1234 - SUT [Server-Type-C2]:
1235 - testbedname: testbed27.
1236 - hostname: s33-t27-sut1.
1237 - IPMI IP: 10.30.55.18
1238 - Host IP: 10.32.8.18
1240 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1241 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1242 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1243 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1244 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1245 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1246 - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1247 - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1248 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1249 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1250 - TG [Server-Type-C3]:
1251 - testbedname: testbed27.
1252 - hostname: s34-t27-tg1.
1253 - IPMI IP: 10.30.55.19
1254 - Host IP: 10.32.8.19
1256 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1257 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1258 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1259 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1260 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1261 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1262 - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1263 - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1264 - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
1265 - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
1266 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1267 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1268 - SUT [Server-Type-C2]:
1269 - testbedname: testbed28.
1270 - hostname: s35-t28-sut1.
1271 - IPMI IP: 10.30.55.20
1272 - Host IP: 10.32.8.20
1274 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1275 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1276 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1277 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1278 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1279 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1280 - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1281 - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1282 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1283 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1284 - TG [Server-Type-C3]:
1285 - testbedname: testbed28.
1286 - hostname: s36-t28-tg1.
1287 - IPMI IP: 10.30.55.21
1288 - Host IP: 10.32.8.21
1290 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1291 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1292 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1293 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1294 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1295 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1296 - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1297 - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1298 - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
1299 - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
1300 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1301 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1302 - SUT [Server-Type-C2]:
1303 - testbedname: testbed29.
1304 - hostname: s37-t29-sut1.
1305 - IPMI IP: 10.30.55.22
1306 - Host IP: 10.32.8.22
1308 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1309 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1310 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1311 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1312 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1313 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1314 - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1315 - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1316 - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1317 - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1318 - TG [Server-Type-C3]:
1319 - testbedname: testbed29.
1320 - hostname: s38-t29-tg1.
1321 - IPMI IP: 10.30.55.23
1322 - Host IP: 10.32.8.23
1324 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1325 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1326 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1327 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1328 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1329 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1330 - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1331 - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1332 - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1333 - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1336 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1339 - SUT [Server-Type-D1]:
1340 - testbedname: testbed210.
1341 - hostname: s60-t210-sut1.
1342 - IPMI IP: 10.30.55.24
1343 - Host IP: 10.32.8.24
1345 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1346 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1347 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1348 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1349 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1350 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1351 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1352 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1353 - TG [Server-Type-D2]:
1354 - testbedname: testbed210.
1355 - hostname: s61-t210-tg1.
1356 - IPMI IP: 10.30.55.25
1357 - Host IP: 10.32.8.25
1359 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1360 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1361 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1362 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1363 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1364 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1365 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1366 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1369 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1371 Note: Server19 (TG) is shared between testbed33 & testbed211
1374 - SUT [Server-Type-E22]:
1375 - testbedname: testbed211.
1376 - hostname: s27-t211-sut1.
1377 - IPMI IP: 10.30.50.69
1378 - Host IP: 10.30.51.69
1380 - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1381 - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1382 - TG [Server-Type-E31]:
1383 - testbedname: testbed33 and testbed211.
1384 - hostname: s19-t33t211-tg1.
1385 - IPMI IP: 10.30.50.46
1386 - Host IP: 10.30.51.49
1388 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1389 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1390 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1391 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1392 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1393 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1394 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1395 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1396 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1397 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1398 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1399 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1402 #### 2-Node-Icelake Servers (2n-icx) PROD
1405 - SUT [Server-Type-F1]:
1406 - testbedname: testbed212.
1407 - hostname: s71-t212-sut1.
1408 - IPMI IP: 10.30.51.81
1409 - Host IP: 10.30.50.81
1411 - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1412 - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1413 - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1414 - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1415 - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1416 - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1417 - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1418 - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1419 - TG [Server-Type-F2]:
1420 - testbedname: testbed212.
1421 - hostname: s72-t212-tg1.
1422 - IPMI IP: 10.30.51.82
1423 - Host IP: 10.30.50.82
1425 - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1426 - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1427 - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1428 - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1429 - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1430 - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1431 - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1432 - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1433 - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1434 - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1435 - SUT [Server-Type-F1]:
1436 - testbedname: testbed213.
1437 - hostname: s83-t213-sut1.
1438 - IPMI IP: 10.30.51.83
1439 - Host IP: 10.30.50.83
1441 - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1442 - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1443 - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1444 - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1445 - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1446 - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1447 - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1448 - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1449 - TG [Server-Type-F2]:
1450 - testbedname: testbed213.
1451 - hostname: s84-t213-tg1.
1452 - IPMI IP: 10.30.51.84
1453 - Host IP: 10.30.50.84
1455 - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1456 - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1457 - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1458 - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1459 - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1460 - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1461 - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1462 - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1463 - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1464 - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1465 - SUT [Server-Type-F1]:
1466 - testbedname: testbed214.
1467 - hostname: s85-t214-sut1.
1468 - IPMI IP: 10.30.51.85
1469 - Host IP: 10.30.50.85
1471 - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1472 - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1473 - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1474 - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1475 - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1476 - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1477 - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1478 - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1479 - TG [Server-Type-F2]:
1480 - testbedname: testbed214.
1481 - hostname: s86-t214-tg1.
1482 - IPMI IP: 10.30.51.86
1483 - Host IP: 10.30.50.86
1485 - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1486 - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1487 - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1488 - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1489 - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1490 - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1491 - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1492 - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1493 - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1494 - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1495 - SUT [Server-Type-F1]:
1496 - testbedname: testbed215.
1497 - hostname: s87-t215-sut1.
1498 - IPMI IP: 10.30.51.87
1499 - Host IP: 10.30.50.87
1501 - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1502 - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1503 - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1504 - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1505 - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1506 - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1507 - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1508 - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1509 - TG [Server-Type-F2]:
1510 - testbedname: testbed215.
1511 - hostname: s88-t215-tg1.
1512 - IPMI IP: 10.30.51.88
1513 - Host IP: 10.30.50.88
1515 - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1516 - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1517 - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1518 - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1519 - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1520 - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1521 - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1522 - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1523 - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1524 - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1527 #### 3-Node-Skylake Servers (3n-skx) PROD
1530 - ServerB11 [Server-Type-B1]:
1531 - testbedname: testbed31.
1532 - hostname: s11-t31-sut1.
1533 - IPMI IP: 10.30.50.43
1534 - Host IP: 10.30.51.46
1536 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1537 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1538 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1539 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1540 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1541 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1542 - ServerB12 [Server-Type-B1]:
1543 - testbedname: testbed31.
1544 - hostname: s12-t31-sut2.
1545 - IPMI IP: 10.30.50.44
1546 - Host IP: 10.30.51.47
1548 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1549 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1550 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1551 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1552 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1553 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1554 - ServerB13 [Server-Type-B2]:
1555 - testbedname: testbed31.
1556 - hostname: s13-t31-tg1.
1557 - IPMI IP: 10.30.50.45
1558 - Host IP: 10.30.51.48
1560 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1561 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1562 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1563 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1564 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1565 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1566 - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1567 - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1568 - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1569 - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1570 - ServerB14 [Server-Type-B1]:
1571 - testbedname: testbed32.
1572 - hostname: s14-t32-sut1.
1573 - IPMI IP: 10.30.50.55
1574 - Host IP: 10.30.51.58
1576 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1577 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1578 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1579 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1580 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1581 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1582 - ServerB15 [Server-Type-B1]:
1583 - testbedname: testbed32.
1584 - hostname: s15-t32-sut2.
1585 - IPMI IP: 10.30.50.56
1586 - Host IP: 10.30.51.59
1588 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1589 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1590 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1591 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1592 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1593 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1594 - ServerB16 [Server-Type-B2]:
1595 - testbedname: testbed32.
1596 - hostname: s16-t32-tg1.
1597 - IPMI IP: 10.30.50.57
1598 - Host IP: 10.30.51.60
1600 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1601 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1602 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1603 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1604 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1605 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1606 - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1607 - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1608 - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1609 - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1612 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1614 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1617 - ServerB22 [Server-Type-B5]:
1618 - testbedname: testbed35.
1619 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1620 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1621 - Host IP: 10.30.51.9
1623 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1624 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1626 - ServerB23 [Server-Type-B5]:
1627 - testbedname: testbed35.
1628 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1629 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1630 - Host IP: 10.30.51.10
1632 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1633 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1635 - ServerB24 [Server-Type-B5]:
1636 - testbedname: testbed35.
1637 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1638 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1639 - Host IP: 10.30.51.11
1641 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1642 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1646 #### 3-Node-Taishan Servers (3n-tsh) PROD
1648 Note: Server19 (TG) is shared between testbed33 & testbed211
1651 - SUT [Server-Type-E21]:
1652 - testbedname: testbed33.
1653 - hostname: s17-t33-sut1.
1654 - IPMI IP: 10.30.50.36
1655 - Host IP: 10.30.51.36
1657 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1658 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1659 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1660 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1661 - SUT [Server-Type-E21]:
1662 - testbedname: testbed33.
1663 - hostname: s18-t33-sut2.
1664 - IPMI IP: 10.30.50.37
1665 - Host IP: 10.30.51.37
1667 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1668 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1669 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1670 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1671 - TG [Server-Type-E31]:
1672 - testbedname: testbed33 and testbed211.
1673 - hostname: s19-t33t211-tg1.
1674 - IPMI IP: 10.30.50.46
1675 - Host IP: 10.30.51.49
1677 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1678 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1679 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1680 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1681 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1682 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1683 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1684 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1685 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1686 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1687 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1688 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1691 #### 3-Node-Altra Servers (3n-alt) PROD
1694 - SUT [Server-Type-E23]:
1695 - testbedname: testbed34.
1696 - hostname: s62-t34-sut1.
1697 - IPMI IP: 10.30.50.72
1698 - Host IP: 10.30.51.72
1700 - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1701 - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1702 - SUT [Server-Type-E23]:
1703 - testbedname: testbed34.
1704 - hostname: s63-t34-sut2.
1705 - IPMI IP: 10.30.50.73
1706 - Host IP: 10.30.51.73
1708 - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1709 - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1710 - TG [Server-Type-F4]:
1711 - testbedname: testbed34.
1712 - hostname: s64-t34-tg1.
1713 - IPMI IP: 10.30.50.74
1714 - Host IP: 10.30.51.74
1716 - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1717 - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1718 - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1719 - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1720 - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1721 - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1722 - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1723 - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1724 - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1725 - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1728 #### 3-Node-Denverton Servers (3n-dnv) PROD
1731 - ServerB30 [Server-Type-B10]:
1732 - testbednames: testbed35.
1733 - hostname: s30-t35-sut1.
1734 - IPMI IP: 10.30.55.12
1735 - Host IP: 10.32.8.12
1737 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1738 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1739 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1740 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1741 - ServerB31 [Server-Type-B10]:
1742 - testbednames: testbed35.
1743 - hostname: s31-t35-sut2.
1744 - IPMI IP: 10.30.55.13
1745 - Host IP: 10.32.8.13
1747 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1748 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1749 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1750 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1753 #### 3-Node-Icelake Servers (3n-icx) PROD
1756 - ServerF1 [Server-Type-F1]:
1757 - testbedname: testbed37.
1758 - hostname: s65-t37-sut1.
1759 - IPMI IP: 10.30.50.75
1760 - Host IP: 10.30.51.75
1762 - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1763 - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1764 - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1765 - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1766 - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1767 - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1768 - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1769 - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1770 - ServerF1 [Server-Type-F1]:
1771 - testbedname: testbed37.
1772 - hostname: s66-t37-sut2.
1773 - IPMI IP: 10.30.50.76
1774 - Host IP: 10.30.51.76
1776 - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1777 - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1778 - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1779 - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1780 - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1781 - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1782 - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1783 - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1784 - ServerF3 [Server-Type-F3]:
1785 - testbedname: testbed37.
1786 - hostname: s67-t37-tg1.
1787 - IPMI IP: 10.30.50.77
1788 - Host IP: 10.30.51.77
1790 - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1791 - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1792 - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1793 - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1794 - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1795 - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1796 - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1797 - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1798 - ServerF1 [Server-Type-F1]:
1799 - testbedname: testbed38.
1800 - hostname: s78-t38-sut1.
1801 - IPMI IP: 10.30.50.78
1802 - Host IP: 10.30.51.78
1804 - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1805 - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1806 - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1807 - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1808 - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1809 - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1810 - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1811 - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1812 - ServerF1 [Server-Type-F1]:
1813 - testbedname: testbed38.
1814 - hostname: s79-t38-sut2.
1815 - IPMI IP: 10.30.50.79
1816 - Host IP: 10.30.51.79
1818 - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1819 - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1820 - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1821 - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1822 - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1823 - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1824 - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1825 - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1826 - ServerF3 [Server-Type-F3]:
1827 - testbedname: testbed38.
1828 - hostname: s80-t38-tg1.
1829 - IPMI IP: 10.30.50.80
1830 - Host IP: 10.30.51.80
1832 - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1833 - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1834 - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1835 - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1836 - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1837 - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1838 - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1839 - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1842 #### 3-Node-SnowRidge Servers (3n-snr) PROD
1845 - ServerG1 [Server-Type-G1]:
1846 - testbedname: testbed39.
1847 - hostname: s93-t39-sut1.
1848 - IPMI IP: 10.30.50.93
1849 - Host IP: 10.30.51.93
1851 - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1852 - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1853 - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
1854 - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
1855 - ServerG1 [Server-Type-G1]:
1856 - testbedname: testbed39.
1857 - hostname: s94-t39-sut2.
1858 - IPMI IP: 10.30.50.94
1859 - Host IP: 10.30.51.94
1861 - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1862 - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1863 - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1864 - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1865 - ServerF4 [Server-Type-F4]:
1866 - testbedname: testbed39.
1867 - hostname: s89-t39t310-tg1.
1868 - IPMI IP: 10.30.50.89
1869 - Host IP: 10.30.51.89
1871 - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1872 - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1873 - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1874 - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1877 ### Per Testbed Wiring
1879 #### 1-Node-Skylake Wiring (1n-skx) PROD
1883 - ring1 10GE-ports x710-4p10GE:
1884 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1885 - ring2 10GE-ports x710-4p10GE:
1886 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1887 - ring3 10GE-ports x710-4p10GE:
1888 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1889 - ring4 10GE-ports x710-4p10GE:
1890 - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1891 - ring5 100GE-ports e810-2p100GE:
1892 - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1893 - ring6 100GE-ports e810-2p100GE:
1894 - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1896 - ring1 10GE-ports x710-4p10GE:
1897 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1898 - ring2 10GE-ports x710-4p10GE:
1899 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1900 - ring3 10GE-ports x710-4p10GE:
1901 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1902 - ring4 10GE-ports x710-4p10GE:
1903 - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1904 - ring5 100GE-ports e810-2p100GE:
1905 - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1906 - ring6 100GE-ports e810-2p100GE:
1907 - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1910 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1914 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1915 - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1916 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1917 - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1918 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1919 - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1920 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1921 - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1924 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1925 - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1926 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1927 - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1928 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1929 - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1930 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1931 - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1934 #### 2-Node-Skylake Wiring (2n-skx) PROD
1938 - ring1 10GE-ports x710-4p10GE on SUT:
1939 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1940 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1941 - ring2 10GE-ports x710-4p10GE on SUT:
1942 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1943 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1944 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1945 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1946 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1947 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1948 - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
1949 - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
1951 - ring1 10GE-ports x710-4p10GE on SUT:
1952 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1953 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1954 - ring2 10GE-ports x710-4p10GE on SUT:
1955 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1956 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1957 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1958 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1959 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1960 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1961 - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
1962 - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
1964 - ring1 10GE-ports x710-4p10GE on SUT:
1965 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1966 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1967 - ring2 10GE-ports x710-4p10GE on SUT:
1968 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1969 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1970 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1971 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1972 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1973 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1974 - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
1975 - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
1977 - ring1 10GE-ports x710-4p10GE on SUT:
1978 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1979 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1980 - ring2 10GE-ports x710-4p10GE on SUT:
1981 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1982 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1983 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1984 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1985 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1986 - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1987 - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
1988 - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
1991 #### 2-Node-Denverton Wiring (2n-dnv) PROD
1995 - ring1 10GE-ports x553 copper port on SUT:
1996 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1997 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1998 - ring2 10GE-ports x553 fiber port on SUT:
1999 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
2000 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
2003 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
2007 - link1 10GE-port x710-4p10GE on SUT:
2008 - t25-tg1-p1 to t25-sut1-c2/p1.
2009 - link2 10GE-port x710-4p10GE on SUT:
2010 - t25-tg1-p2 to t25-sut1-c2/p2.
2011 - link3 10GE-port x710-4p10GE on SUT:
2012 - t25-tg1-p3 to t25-sut1-c2/p3.
2013 - link4 10GE-port x710-4p10GE on SUT:
2014 - t25-tg1-p4 to t25-sut1-c2/p4.
2017 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
2021 - ring1 10GE-ports x710-4p10GE on SUT:
2022 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
2023 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
2024 - ring2 10GE-ports x710-4p10GE on SUT:
2025 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
2026 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
2027 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2028 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
2029 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
2030 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2031 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
2032 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
2033 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
2034 - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
2035 - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
2036 - ring6 100GE-ports e810-2p100GE on TG:
2037 - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
2038 - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
2040 - ring1 10GE-ports x710-4p10GE on SUT:
2041 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
2042 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
2043 - ring2 10GE-ports x710-4p10GE on SUT:
2044 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
2045 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
2046 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2047 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
2048 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
2049 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2050 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
2051 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
2052 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
2053 - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
2054 - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
2055 - ring6 100GE-ports e810-2p100GE on TG:
2056 - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
2057 - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
2059 - ring1 10GE-ports x710-4p10GE on SUT:
2060 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
2061 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
2062 - ring2 10GE-ports x710-4p10GE on SUT:
2063 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
2064 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
2065 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2066 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
2067 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
2068 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2069 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
2070 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
2071 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
2072 - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
2073 - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
2076 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
2080 - ring1 10GE-ports x710-4p10GE on SUT:
2081 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
2082 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
2083 - ring2 10GE-ports x710-4p10GE on SUT:
2084 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
2085 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
2086 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2087 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
2088 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
2089 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2090 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
2091 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
2094 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
2098 - ring1 10GE-ports x520-2p10GE on SUTs:
2099 - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
2100 - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
2103 #### 2-Node-Icelake Wiring (2n-icx) PROD
2107 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2108 - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
2109 - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
2110 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2111 - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
2112 - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
2113 - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
2114 - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
2115 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2116 - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
2117 - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
2118 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2119 - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
2120 - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
2122 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2123 - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
2124 - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
2125 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2126 - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
2127 - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
2128 - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
2129 - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
2130 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2131 - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
2132 - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
2133 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2134 - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
2135 - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
2137 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2138 - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
2139 - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
2140 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2141 - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
2142 - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
2143 - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
2144 - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
2145 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2146 - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
2147 - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
2148 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2149 - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
2150 - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
2152 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2153 - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
2154 - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
2155 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2156 - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
2157 - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
2158 - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
2159 - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
2160 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2161 - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
2162 - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
2163 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2164 - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
2165 - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
2168 #### 3-Node-Skylake Wiring (3n-skx) PROD
2172 - ring1 10GE-ports x710-4p10GE on SUTs:
2173 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
2174 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
2175 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
2176 - ring2 10GE-ports x710-4p10GE on SUT:
2177 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
2178 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
2179 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
2180 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2181 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
2182 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
2183 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
2184 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
2185 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
2186 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
2187 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
2188 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
2189 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
2190 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
2192 - ring1 10GE-ports x710-4p10GE on SUTs:
2193 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
2194 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
2195 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
2196 - ring2 10GE-ports x710-4p10GE on SUT:
2197 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
2198 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
2199 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
2200 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2201 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
2202 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
2203 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
2204 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
2205 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
2206 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
2207 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
2208 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
2209 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
2210 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
2213 #### 3-Node-Rangeley Wiring (3n-rng) VERIFY
2219 #### 3-Node-Taishan Wiring (3n-tsh) PROD
2223 - ring1 10GE-ports x520-2p10GE on SUTs:
2224 - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
2225 - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
2226 - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
2227 - ring2 25GE-ports cx4-2p25GE on SUTs:
2228 - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
2229 - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
2230 - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
2233 #### 3-Node-Altra Wiring (3n-alt) PROD
2237 - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
2238 - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
2239 - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
2240 - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
2243 #### 3-Node-Denverton Wiring (3n-dnv) PROD
2247 - ring1 10GE-ports x553 copper port on SUTs:
2248 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
2249 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
2250 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
2251 - ring2 10GE-ports x553 fiber port on SUTs:
2252 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
2253 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
2254 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
2257 #### 3-Node-Icelake Wiring (3n-icx) PROD
2261 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
2262 - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
2263 - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
2264 - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
2265 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
2266 - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
2267 - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
2268 - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
2269 - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
2270 - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
2271 - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
2272 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
2273 - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
2274 - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
2275 - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
2277 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
2278 - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
2279 - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
2280 - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
2281 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
2282 - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
2283 - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
2284 - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
2285 - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
2286 - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
2287 - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
2288 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
2289 - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
2290 - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
2291 - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
2294 #### 3-Node-SnowRidge Wiring (3n-snr) PROD
2298 - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
2299 - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
2300 - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
2301 - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
2302 - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
2303 - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
2304 - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
2312 1. Ixia PerfectStorm One Appliance
2314 - Chassis: PS10GE4NG.
2315 - Motherboard: SuperMicro X11DPG-QT.
2316 - Processors: Quad-Core, Intel Processor.
2317 - HW accelerators: FPGA offload.
2319 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
2320 - Physical Interfaces: 4 * 10GE SFP+.
2321 - Operating System: Native IxOS.
2327 1. Arm Cortex A-72 servers
2328 - 2 * ThunderX2 (VPP Device)
2329 - Chassis: GIGABYTE Rack Mount
2330 - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
2331 - RAM Memory: 16* 16GB DIMM
2332 - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
2333 - 1 * ThunderX2 (Performance)
2334 - Chassis: GIGABYTE Rack Mount
2335 - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
2336 - RAM Memory: 4* 32GB RDIMM
2337 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
2338 - 2 * Huawei TaiShan 2280.
2339 - Chassis: Huawei TaiShan 2280.
2340 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
2341 - RAM Memory: 8* 16GB DDR4-2400MT/s.
2342 - Disks: 1* 4TB SATA HDD.
2343 2. Arm Neoverse N1 servers
2344 - 2 * Ampere Altra (Performance)
2345 - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
2346 - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
2347 - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
2348 - RAM Memory: 16* 8GB DDR4-3200MT/s
2349 - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
2350 - 2 * Ampere Altra (Build)
2351 - Chassis: Gigabyte R152-P30-00 1U
2352 - Motherboard: MP32-AR1-00
2353 - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
2354 - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
2355 - RAM Memory: 12* 16GB DDR4-3200MT/s
2356 - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
2359 ### Xeon and Atom Servers
2362 1. Intel Xeon servers:
2363 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
2364 - Chassis: SuperMicro SYS-7049GP-TRT.
2365 - Motherboard: SuperMicro X11DPG-QT.
2366 - Processors: 2* Intel Platinum 8180 2.5 GHz.
2367 - RAM Memory: 16* 16GB DDR4-2666MHz.
2368 - Disks: 2* 1.6TB 6G SATA SSD.
2369 2. Intel Atom servers with Rangely processors.
2370 - 3 * Netgate XG-2758-1u
2371 - Chassis: Netgate XG-2758-1u
2372 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
2373 - RAM Memory: 16GB ECC
2377 ### Network Interface Cards
2390 ### Pluggables and Cables