1 # FD.io CSIT Testbed Specifications
3 1. [FD.io CSIT Testbed Specifications](#fdio-csit-testbed-specifications)
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
9 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
10 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
11 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
12 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
13 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
14 1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
15 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
16 1. [Server Management](#server-management)
17 1. [Requirements](#requirements)
18 1. [Addressing](#addressing)
19 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
20 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
21 1. [Server Type Specification](#server-type-specification)
22 1. [Server and Port Naming](#server-and-port-naming)
23 1. [Testbeds Configuration](#testbeds-configuration)
24 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
25 1 [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
26 1 [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
27 1 [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
28 1 [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
29 1 [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
30 1 [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
31 1 [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
32 1 [3-Node-Rangeley (3n-rng) VERIFY](#3-node-rangeley-3n-rng-verify)
33 1 [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip)
34 1 [3-Node-Mcbin (3n-mcb) TODO](#3-node-mcbin-3n-mcb-todo)
35 1. [Per Testbed Wiring](#per-testbed-wiring)
36 1 [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
37 1 [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
38 1 [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
39 1 [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
40 1 [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
41 1 [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
42 1 [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
43 1 [3-Node-Rangeley (3n-rng) TODO](#3-node-rangeley-3n-rng-todo)
44 1 [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip)
45 1 [3-Node-Mcbin (3n-mcb) WIP](#3-node-mcbin-3n-mcb-wip)
46 1. [Inventory](#inventory)
47 1. [Appliances](#appliances)
48 1. [Arm Servers](#arm-servers)
49 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
50 1. [Network Interface Cards](#network-interface-cards)
51 1. [Pluggables and Cables](#pluggables-and-cables)
52 1. [Other Parts](#other-parts)
54 ## FD.io CSIT Testbed Specifications
56 This note includes specification of the physical testbed infrastructure
57 hosted by LFN FD.io CSIT project.
64 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
65 1. 1-Node-Skylake func skx na 2 2 0 0 2 0 0 0 0 0 0
66 2. 1-Node-Thunderx2 func tx2 na 1 1 0 0 0 0 0 0 1 0 0
67 3. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0
68 4. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0
69 5. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0
70 6. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0
71 7. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0
72 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0
73 9. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0
74 10. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2
75 11. 1-Node-VIRL func hsw --- 3 3 0 3 0 0 0 0 0 0 0
76 Totals: 17 26 14 12 19 1 2 1 1 2 2
79 ### 1-Node-Skylake Xeon Intel (1n-skx)
81 Each 1-Node-Skylake testbed includes one SUT (Type-B6 server) with NIC
82 ports connected back-to-back.
83 Used for FD.io VPP_Device functional driver tests.
85 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
87 Each 1-Node-ThunderX2 testbed includes one SUT (Type-B9 server) with NIC
88 ports connected back-to-back.
89 Used for FD.io VPP_Device functional driver tests.
91 ### 2-Node-Skylake Xeon Intel (2n-skx)
93 Each 2-Node-Skylake testbed includes one SUT (Type-B1 server) and one TG
94 (Type-B2 server) connected back-to-back.
95 Used for FD.io performance tests.
97 ### 2-Node-Denverton Atom Intel (2n-dnv)
99 Each 2-Node-Skylake testbed includes one SUT (Type-B10 server) and one TG
100 (Type-B2 server) connected back-to-back.
101 Used for FD.io performance tests.
103 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
105 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Type-B1 server) and one
106 TG (Ixia PSOne appliance) with 10GE interfaces connected back-to-back.
107 Used for FD.io TCP/IP and HTTP performance tests.
109 ### 3-Node-Haswell Xeon Intel (3n-skx)
111 ### 3-Node-Skylake Xeon Intel (3n-skx)
113 Each 3-Node-Skylake testbed includes two SUTs (Type-B1 servers) and one
114 TG (Type-B2 server) connected in full-mesh triangle.
115 Used for FD.io performance tests.
117 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
119 Each 3-Node-TaiShan testbed includes two SUTs (Type-B3 server) and one TG
120 (Type-B2 server) connected in full-mesh triangle.
121 Used for FD.io performance tests.
123 ### 3-Node-MACCHIATObin Arm Marvell
125 Each 3-Node-MACCHIATObin testbed includes two SUTs (Type-B4 server) and
126 one TG (Type-B2 server) connected in full-mesh triangle.
127 Used for FD.io performance tests.
129 ### 3-Node-Rangeley Atom Testbeds
131 Each 3-Node-Rangeley testbed includes two SUTs (Type-B5 Netgate device)
132 and one TG (Type-2 server) connected in full-mesh triangle.
133 Used for FD.io performance tests.
139 For management purposes, each server must have following two ports
140 connected to the management network:
144 - IPMI - Intelligent Platform Management Interface.
145 - Required for access to embedded server management with WebUI, CLI, SNMPv3,
146 IPMIv2.0, for firmware (BIOS) and OS updates.
147 - 1GE/10GE/40GE management port
148 - hostOS management port for general system management.
153 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management
154 port, which are connected to two different VLANs.
158 - Subnet: 10.30.50.0/24
159 - Gateway: 10.30.50.1
160 - Broadcast: 10.30.50.255
161 - DNS1: 199.204.44.24
162 - DNS2: 199.204.47.54
164 - Subnet: 10.30.51.0/24
165 - Gateway: 10.30.51.1
166 - Broadcast: 10.30.51.255
167 - DNS1: 199.204.44.24
168 - DNS2: 199.204.47.54
171 To access these hosts, VPN connection is required.
173 ### LOM (IPMI) VLAN IP Addresses
176 ------------ | -------
179 10.30.50.2 | LF Reserved
180 10.30.50.3 | LF Reserved
181 10.30.50.4 | LF Reserved
182 10.30.50.5 | LF Reserved
183 10.30.50.6 | LF Reserved
184 10.30.50.7 | LF Reserved
185 10.30.50.8 | LF Reserved
186 10.30.50.9 | LF Reserved
187 10.30.50.10 | LF Reserved
188 10.30.50.11 | LF Reserved
189 10.30.50.12 | LF Reserved
190 10.30.50.13 | LF Reserved
191 10.30.50.14 | LF Reserved
192 10.30.50.15 | LF Reserved
194 10.30.50.17 | t1-sut1
195 10.30.50.18 | t1-sut2
197 10.30.50.21 | t2-sut1
198 10.30.50.22 | t2-sut2
200 10.30.50.25 | t3-sut1
201 10.30.50.26 | t3-sut-2
202 10.30.50.28 | t4-sut1
203 10.30.50.29 | t4-sut2
204 10.30.50.30 | t4-sut3
205 10.30.50.36 | s17-t33-sut1
206 10.30.50.37 | s18-t33-sut2
207 10.30.50.41 | s3-t21-sut1
208 10.30.50.42 | s4-t21-tg1
209 10.30.50.43 | s11-t31-sut1
210 10.30.50.44 | s12-t31-sut2
211 10.30.50.45 | s13-t31-tg1
212 10.30.50.46 | s19-t33t34-tg1
213 10.30.50.47 | s1-t11-sut1
214 10.30.50.48 | s2-t12-sut1
215 10.30.50.49 | s5-t22-sut1
216 10.30.50.50 | s6-t22-tg1
217 10.30.50.51 | s7-t23-sut1
218 10.30.50.52 | s8-t23-tg1
219 10.30.50.53 | s9-t24-sut1
220 10.30.50.54 | s10-t24-tg1
221 10.30.50.55 | s14-t32-sut1
222 10.30.50.56 | s15-t32-sut2
223 10.30.50.57 | s16-t32-tg1
224 10.30.50.58 | s25-t25-sut1
225 10.30.50.59 | s26-t25-tg1
226 10.30.50.69 | s27-t13-sut
227 10.30.50.255 | Broadcast
229 ### Management VLAN IP Addresses
232 ------------------------- | -------
235 10.30.51.2 | LF Reserved
236 10.30.51.3 | LF Reserved
237 10.30.51.4 | LF Reserved
238 10.30.51.5 | LF Reserved
239 10.30.51.6 | LF Reserved
240 10.30.51.7 | LF Reserved
241 10.30.51.8 | LF Reserved
242 10.30.51.9 | s22-t35-sut1 (netgate-1)
243 10.30.51.10 | s23-t35-sut2 (netgate-2)
244 10.30.51.11 | s24-t35-sut3 (netgate-3)
245 10.30.51.12 | softiron-1
246 10.30.51.13 | softiron-2
247 10.30.51.14 | softiron-3
248 10.30.51.15 | LF Reserved
250 10.30.51.17 | t1-sut1
251 10.30.51.18 | t1-sut2
253 10.30.51.21 | t2-sut1
254 10.30.51.22 | t2-sut2
256 10.30.51.25 | t3-sut1
257 10.30.51.26 | t3-sut-2
258 10.30.51.28 | t4-sut1
259 10.30.51.29 | t4-sut2
260 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0, TO BE VERIFIED
261 10.30.51.30 | t4-sut3
262 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1, TO BE VERIFIED
263 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2, TO BE VERIFIED
264 10.30.51.36 | s17-t33-sut1
265 10.30.51.37 | s18-t33-sut2
266 10.30.51.41 | s20-t34-sut1
267 10.30.51.42 | s21-t34-sut2
268 10.30.51.44 | s3-t21-sut1
269 10.30.51.45 | s4-t21-tg1
270 10.30.51.46 | s11-t31-sut1
271 10.30.51.47 | s12-t31-sut2
272 10.30.51.48 | s13-t31-tg1
273 10.30.51.49 | s19-t33t34-tg1
274 10.30.51.50 | s1-t11-sut1
275 10.30.51.51 | s2-t12-sut1
276 10.30.51.52 | s5-t22-sut1
277 10.30.51.53 | s6-t22-tg1
278 10.30.51.54 | s7-t23-sut1
279 10.30.51.55 | s8-t23-tg1
280 10.30.51.56 | s9-t24-sut1
281 10.30.51.57 | s10-t24-tg1
282 10.30.51.58 | s14-t32-sut1
283 10.30.51.59 | s15-t32-sut2
284 10.30.51.60 | s16-t32-tg1
285 10.30.51.61 | s25-t25-sut1
286 10.30.51.62 | s26-t25-tg1
287 10.30.51.69 | s27-t13-sut1
288 10.30.51.70-10.30.51.105 | VIRL1 TO BE VERIFIED
289 10.30.51.106-10.30.51.180 | VIRL2
290 10.30.51.181-10.30.51.254 | VIRL3
291 10.30.51.255 | Broadcast
293 ## Server Type Specification
295 FD.io CSIT lab contains following server types:
297 1. Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
298 - Quantity: 6 servers.
299 - Physical connectivity:
300 - CIMC and host management ports.
301 - NIC ports connected in 3-node topologies.
302 - Main HW configuration:
303 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
304 - Processors: 2* E5-2699v3 2.3 GHz.
305 - RAM Memory: 16* 32GB DDR4-2133MHz.
306 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
307 - NICs configuration:
308 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
309 - PCIe Slot1: Cisco VIC 1385 2p40GE.
310 - PCIe Slot2: Intel NIC x520 2p10GE.
312 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
313 - PCIe Slot4: Intel NIC xl710 2p40GE.
314 - PCIe Slot5: Intel NIC x710 2p10GE.
315 - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
316 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
317 2. Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
318 - Quantity: 3 servers.
319 - Physical connectivity:
320 - CIMC and host management ports.
321 - NIC ports connected in 3-node topologies.
322 - Main HW configuration:
323 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
324 - Processors: 2* E5-2699v3 2.3 GHz.
325 - RAM Memory: 16* 32GB DDR4-2133MHz.
326 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
327 - NICs configuration:
328 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
329 - PCIe Slot1: Intel NIC xl710 2p40GE.
330 - PCIe Slot2: Intel NIC x710 2p10GE.
331 - PCIe Slot3: Intel NIC x710 2p10GE.
332 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
333 - PCIe Slot4: Intel NIC xl710 2p40GE.
334 - PCIe Slot5: Intel NIC x710 2p10GE.
335 - PCIe Slot6: Intel NIC x710 2p10GE.
337 3. Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
338 - Quantity: 3 servers.
339 - Physical connectivity:
340 - CIMC and host management ports.
341 - no NIC ports, standalone setup.
342 - Main HW configuration:
343 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
344 - Processors: 2* E5-2699v3 2.3 GHz.
345 - RAM Memory: 16* 32GB DDR4-2133MHz.
346 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
347 - NICs configuration:
348 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
350 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
353 4. Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
355 - Physical connectivity:
356 - IPMI and host management ports.
357 - NIC ports connected into 2-node and 3-node topologies.
358 - Main HW configuration:
359 - Chassis: SuperMicro SYS-7049GP-TRT.
360 - Motherboard: SuperMicro X11DPG-QT.
361 - Processors: 2* Intel Platinum 8180 2.3 GHz.
362 - RAM Memory: 16* 16GB DDR4-2666MHz.
363 - Disks: 2* 1.6TB 6G SATA SSD.
364 - NICs configuration:
365 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
366 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
367 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
368 - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
369 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
370 - PCIe Slot6 86:00.xx: empty.
371 - PCIe Slot8 af:00.xx: empty.
372 - PCIe Slot10 d8:00.xx: empty.
373 2. Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
375 - Physical connectivity:
376 - IPMI and host management ports.
377 - NIC ports connected into 2-node and 3-node topologies.
378 - Main HW configuration:
379 - Chassis: SuperMicro SYS-7049GP-TRT.
380 - Motherboard: SuperMicro X11DPG-QT.
381 - Processors: 2* Intel Platinum 8180 2.3 GHz.
382 - RAM Memory: 16* 16GB DDR4-2666MHz.
383 - Disks: 2* 1.6TB 6G SATA SSD.
384 - NICs configuration:
385 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
386 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
387 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
388 - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
389 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
390 - PCIe Slot6 86:00.xx: empty.
391 - PCIe Slot8 af:00.xx: empty.
392 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
393 3. Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
395 - Physical connectivity:
396 - IPMI(?) and host management ports.
397 - NIC ports connected into 3-node topology.
398 - Main HW configuration:
399 - Chassis: Huawei TaiShan 2280.
400 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
401 - RAM Memory: 8* 16GB DDR4-2400MT/s
402 - Disks: 1* 4TB SATA HDD
403 - NICs configuration:
404 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
405 - PCIe Slot6 11:00.xx: 82599-2p10GE Intel.
406 4. Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
408 - Physical connectivity:
409 - Host management ports.
410 - NIC ports connected into 2-node and 3-node topologies.
411 - Main HW configuration:
412 - Chassis: MACCHIATObin.
413 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
414 - RAM Memory: 1* 16GB DDR4
415 - Disks: 1* 128GB(?) SATA SDD
416 - NICs configuration:
417 - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
418 5. Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
419 - Quantity: TBD based on testbed allocation.
420 - Physical connectivity:
421 - Management: serial Port (usb) for console
422 - NIC ports connected into 2-node.
423 - Main HW configuration:
424 - Chassis: Netgate XG-2758-1u
425 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
426 - RAM Memory: 16GB ECC
428 - NICs configuration:
429 - 2x 10Gb Intel 82599ES
431 6. Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
433 - Physical connectivity:
434 - IPMI and host management ports.
435 - NIC ports connected into 2-node and 3-node topologies.
436 - Main HW configuration:
437 - Chassis: SuperMicro SYS-7049GP-TRT.
438 - Motherboard: SuperMicro X11DPG-QT.
439 - Processors: 2* Intel Platinum 8180 2.3 GHz.
440 - RAM Memory: 16* 16GB DDR4-2666MHz.
441 - Disks: 2* 1.6TB 6G SATA SSD.
442 - NICs configuration:
443 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
444 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
445 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
446 - PCIe Slot9 5e:00.xx: empty.
447 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
448 - PCIe Slot6 86:00.xx: empty.
449 - PCIe Slot8 af:00.xx: empty.
450 - PCIe Slot10 d8:00.xx: empty.
451 7. Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
453 - Physical connectivity:
454 - Host management interface: 10/100/1000-BaseT.
455 - 8-port 10GE SFP+ integrated NIC.
456 - Main HW configuration:
457 - Chassis: PS10GE4NG.
458 - Motherboard: SuperMicro X11DPG-QT.
459 - Processors: Quad-Core, Intel Processor.
460 - HW accelerators: FPGA offload.
462 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
463 - Physical Interfaces: 4 * 10GE SFP+.
464 - Operating System: Native IxOS.
465 - Interface configuration:
470 8. Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
472 - Physical connectivity:
473 - IPMI and host management ports.
475 - Main HW configuration:
476 - Chassis: SuperMicro SYS-7049GP-TRT.
477 - Motherboard: SuperMicro X11DPG-QT.
478 - Processors: 2* Intel Platinum 8180 2.3 GHz.
479 - RAM Memory: 16* 16GB DDR4-2666MHz.
480 - Disks: 2* 1.6TB 6G SATA SSD.
481 - NICs configuration:
482 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
483 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
484 - PCIe Slot4 3b:00.xx: empty.
485 - PCIe Slot9 5e:00.xx: empty.
486 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
487 - PCIe Slot6 86:00.xx: empty.
488 - PCIe Slot8 af:00.xx: empty.
489 - PCIe Slot10 d8:00.xx: empty.
490 9. Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
492 - Physical connectivity:
493 - IPMI and host management ports.
494 - NIC ports connected into 1-node topologies.
495 - Main HW configuration:
496 - Chassis: Gigabyte R181-T90 1U
497 - Motheboard: MT91-FS1
498 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
499 - RAM Memory: 4* 32GB RDIMM
500 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
501 - NICs configuration:
503 - PCIe Slot1 05:00.xx: XL710-QDA2.
504 - PCIe Slot3 08:00.xx: XL710-QDA2.
506 - PCIe Slot6 85:00.xx: XL710-QDA2.
507 10. Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
509 - Physical connectivity:
510 - IPMI and host management ports.
512 - Main HW configuration:
513 - Chassis: SuperMicro SYS-E300-9A
514 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
515 - RAM Memory: 32GB ECC
517 - NICs configuration:
518 - 2x 10Gb Intel x553 fiber ports
519 - 2x 10Gb Intel x553 copper ports
520 - 4x 1GB Intel I350 ports
523 ### Server and Port Naming
525 Following naming convention is used within this page to specify physical
526 connectivity and wiring across defined CSIT testbeds:
529 - testbedname: testbedN.
531 - traffic-generator: tN-tgW.
532 - system-under-testX: tN-sutX.
537 - N - testbed number.
538 - tgW - server acts as traffic-generator with W index.
539 - sutX - server acts as system-under-test with X index.
540 - Y - PCIe slot number denoting a NIC card number within the host.
541 - Z - port number on the NIC card.
544 ## Testbeds Configuration
546 ### Per Testbed Server Allocation and Naming
548 #### 1-Node-Skylake (1n-skx) PROD
551 - ServerB1 [Type-B6]:
552 - testbedname: testbed11.
553 - hostname: s1-t11-sut1.
554 - IPMI IP: 10.30.50.47
555 - Host IP: 10.30.51.50
557 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
558 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
559 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
560 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
561 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
562 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
563 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
564 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
565 - ServerB2 [Type-B6]:
566 - testbedname: testbed12.
567 - hostname: s2-t12-sut1.
568 - IPMI IP: 10.30.50.48
569 - Host IP: 10.30.51.51
571 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
572 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
573 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
574 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
575 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
576 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
577 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
578 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
581 #### 1-Node-Thunderx2 (1n-tx2) WIP
584 - ServerB17 [Type-B9]:
585 - testbedname: testbed13.
586 - hostname: s27-t13-sut1.
587 - IPMI IP: 10.30.50.69
588 - Host IP: 10.30.51.69
590 - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
591 - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
592 - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
593 - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
594 - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
595 - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
598 #### 2-Node-Skylake (2n-skx) PROD
601 - ServerB3 [Type-B1]:
602 - testbedname: testbed21.
603 - hostname: s3-t21-sut1.
604 - IPMI IP: 10.30.50.41
605 - Host IP: 10.30.51.44
607 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
608 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
609 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
610 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
611 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
612 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
613 - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
614 - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
615 - ServerB4 [Type-B2]:
616 - testbedname: testbed21.
617 - hostname: s4-t21-tg1.
618 - IPMI IP: 10.30.50.42
619 - Host IP: 10.30.51.45
621 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
622 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
623 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
624 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
625 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
626 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
627 - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
628 - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
629 - ServerB5 [Type-B1]:
630 - testbedname: testbed22.
631 - hostname: s5-t22-sut1.
632 - IPMI IP: 10.30.50.49
633 - Host IP: 10.30.51.52
635 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
636 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
637 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
638 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
639 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
640 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
641 - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
642 - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
643 - ServerB6 [Type-B2]:
644 - testbedname: testbed22.
645 - hostname: s6-t22-tg1.
646 - IPMI IP: 10.30.50.50
647 - Host IP: 10.30.51.53
649 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
650 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
651 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
652 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
653 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
654 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
655 - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
656 - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
657 - ServerB7 [Type-B1]:
658 - testbedname: testbed23.
659 - hostname: s7-t23-sut1.
660 - IPMI IP: 10.30.50.51
661 - Host IP: 10.30.51.54
663 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
664 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
665 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
666 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
667 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
668 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
669 - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
670 - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
671 - ServerB8 [Type-B2]:
672 - testbedname: testbed23.
673 - hostname: s8-t23-tg1.
674 - IPMI IP: 10.30.50.52
675 - Host IP: 10.30.51.55
677 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
678 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
679 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
680 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
681 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
682 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
683 - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
684 - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
685 - ServerB9 [Type-B1]:
686 - testbedname: testbed24.
687 - hostname: s9-t24-sut1.
688 - IPMI IP: 10.30.50.53
689 - Host IP: 10.30.51.56
691 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
692 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
693 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
694 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
695 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
696 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
697 - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
698 - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
699 - ServerB10 [Type-B2]:
700 - testbedname: testbed24.
701 - hostname: s10-t24-tg1.
702 - IPMI IP: 10.30.50.54
703 - Host IP: 10.30.51.57
705 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
706 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
707 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
708 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
709 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
710 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
711 - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
712 - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
715 #### 2-Node-Denverton (2n-dnv) TODO
721 #### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
724 - ServerB25 [Type-B8]:
725 - testbedname: testbed25.
726 - hostname: s25-t25-sut1.
727 - IPMI IP: 10.30.50.58
728 - Host IP: 10.30.51.61
730 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
731 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
732 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
733 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
734 - ServerB26 [Type-B7]:
735 - testbedname: testbed25.
736 - hostname: s26-t25-tg1.
737 - IPMI IP: 10.30.50.59
738 - Host IP: 10.30.51.62
740 - s26-t25-tg1-p1 - 10GE-port1.
741 - s26-t25-tg1-p2 - 10GE-port2.
742 - s26-t25-tg1-p3 - 10GE-port3.
743 - s26-t25-tg1-p4 - 10GE-port4.
746 #### 3-Node-Haswell (3n-hsw) PROD
749 1. Server1 of Type-1:
750 - testbedname: testbed1.
752 - CIMC IP: 10.30.50.17
753 - Host IP: 10.30.51.17
755 - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
756 - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
757 - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
758 - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
759 - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
760 - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
761 - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
762 - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
763 - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
764 - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
765 2. Server2 of Type-1:
766 - testbedname: testbed1.
768 - CIMC IP: 10.30.50.18
769 - Host IP: 10.30.51.18
771 - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
772 - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
773 - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
774 - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
775 - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
776 - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
777 - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
778 - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
779 - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
780 - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
781 3. Server3 of Type-2:
782 - testbedname: testbed1.
784 - CIMC IP: 10.30.50.16
785 - Host IP: 10.30.51.16
787 - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
788 - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
789 - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
790 - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
791 - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
792 - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
793 - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
794 - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
795 - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
796 - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
797 - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
798 - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
799 4. Server4 of Type-1:
800 - testbedname: testbed2.
802 - CIMC IP: 10.30.50.21
803 - Host IP: 10.30.51.21
805 - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
806 - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
807 - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
808 - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
809 - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
810 - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
811 - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
812 - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
813 - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
814 - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
815 5. Server5 of Type-1:
816 - testbedname: testbed2.
818 - CIMC IP: 10.30.50.22
819 - Host IP: 10.30.51.22
821 - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
822 - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
823 - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
824 - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
825 - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
826 - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
827 - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
828 - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
829 - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
830 - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
831 6. Server6 of Type-2:
832 - testbedname: testbed2.
834 - CIMC IP: 10.30.50.20
835 - Host IP: 10.30.51.20
837 - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
838 - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
839 - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
840 - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
841 - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
842 - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
843 - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
844 - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
845 - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
846 - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
847 - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
848 - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
849 7. Server7 of Type-1:
850 - testbedname: testbed3.
852 - CIMC IP: 10.30.50.25
853 - Host IP: 10.30.51.25
855 - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
856 - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
857 - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
858 - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
859 - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
860 - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
861 - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
862 - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
863 - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
864 - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
865 8. Server8 of Type-1:
866 - testbedname: testbed3.
868 - CIMC IP: 10.30.50.26
869 - Host IP: 10.30.51.26
871 - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
872 - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
873 - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
874 - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
875 - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
876 - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
877 - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
878 - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
879 - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
880 - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
881 9. Server9 of Type-2:
882 - testbedname: testbed3.
884 - CIMC IP: 10.30.50.24
885 - Host IP: 10.30.51.24
887 - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
888 - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
889 - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
890 - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
891 - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
892 - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
893 - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
894 - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
895 - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
896 - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
897 - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
898 - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
901 #### 3-Node-Skylake (3n-skx) PROD
904 - ServerB11 [Type-B1]:
905 - testbedname: testbed31.
906 - hostname: s11-t31-sut1.
907 - IPMI IP: 10.30.50.43
908 - Host IP: 10.30.51.46
910 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
911 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
912 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
913 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
914 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
915 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
916 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
917 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
918 - ServerB12 [Type-B1]:
919 - testbedname: testbed31.
920 - hostname: s12-t31-sut2.
921 - IPMI IP: 10.30.50.44
922 - Host IP: 10.30.51.47
924 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
925 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
926 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
927 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
928 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
929 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
930 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
931 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
932 - ServerB13 [Type-B2]:
933 - testbedname: testbed31.
934 - hostname: s13-t31-tg1.
935 - IPMI IP: 10.30.50.45
936 - Host IP: 10.30.51.48
938 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
939 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
940 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
941 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
942 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
943 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
944 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
945 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
946 - ServerB14 [Type-B1]:
947 - testbedname: testbed32.
948 - hostname: s14-t32-sut1.
949 - IPMI IP: 10.30.50.55
950 - Host IP: 10.30.51.58
952 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
953 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
954 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
955 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
956 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
957 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
958 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
959 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
960 - ServerB15 [Type-B1]:
961 - testbedname: testbed32.
962 - hostname: s15-t32-sut2.
963 - IPMI IP: 10.30.50.56
964 - Host IP: 10.30.51.59
966 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
967 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
968 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
969 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
970 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
971 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
972 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
973 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
974 - ServerB16 [Type-B2]:
975 - testbedname: testbed32.
976 - hostname: s16-t32-tg1.
977 - IPMI IP: 10.30.50.57
978 - Host IP: 10.30.51.60
980 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
981 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
982 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
983 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
984 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
985 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
986 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
987 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
990 Note: ServerB19 (TG) is shared between testbed33 & testbed34
992 #### 3-Node-Rangeley (3n-rng) VERIFY
994 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
997 - ServerB22 [Type-B5]:
998 - testbedname: testbed35.
999 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1000 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1001 - Host IP: 10.30.51.9
1003 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1004 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1006 - ServerB23 [Type-B5]:
1007 - testbedname: testbed35.
1008 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1009 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1010 - Host IP: 10.30.51.10
1012 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1013 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1015 - ServerB24 [Type-B5]:
1016 - testbedname: testbed35.
1017 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1018 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1019 - Host IP: 10.30.51.11
1021 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1022 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1026 #### 3-Node-Taishan (3n-tsh) WIP
1029 - ServerB17 [Type-B3]:
1030 - testbedname: testbed33.
1031 - hostname: s17-t33-sut1.
1032 - IPMI IP: 10.30.50.36
1033 - Host IP: 10.30.51.36
1035 - s17-t33-sut1-c6/p1 - 10GE-port1 82599-2p10GE.
1036 - s17-t33-sut1-c6/p2 - 10GE-port2 82599-2p10GE.
1037 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1038 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1039 - ServerB18 [Type-B3]:
1040 - testbedname: testbed33.
1041 - hostname: s18-t33-sut2.
1042 - IPMI IP: 10.30.50.37
1043 - Host IP: 10.30.51.37
1045 - s18-t33-sut2-c6/p1 - 10GE-port1 82599-2p10GE.
1046 - s18-t33-sut2-c6/p2 - 10GE-port2 82599-2p10GE.
1047 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1048 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1049 - ServerB19 [Type-B2]:
1050 - testbednames: testbed33 and testbed34.
1051 - hostname: s19-t33t34-tg1.
1052 - IPMI IP: 10.30.50.46
1053 - Host IP: 10.30.51.49
1055 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1056 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1057 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1058 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1059 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1060 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1061 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1062 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1063 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1064 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1065 - ServerB20 [Type-B4]:
1066 - testbedname: testbed34.
1067 - hostname: s20-t34-sut1.
1069 - Host IP: 10.30.51.41
1071 - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1072 - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1073 - ServerB21 [Type-B4]:
1074 - testbedname: testbed34.
1075 - hostname: s21-t34-sut2.
1077 - Host IP: 10.30.51.42
1079 - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1080 - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1083 #### 3-Node-Mcbin (3n-mcb) TODO
1089 ### Per Testbed Wiring
1091 #### 1-Node-Skylake (1n-skx) PROD
1095 - ring1 10GE-ports x710-4p10GE:
1096 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1097 - ring2 10GE-ports x710-4p10GE:
1098 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1099 - ring3 10GE-ports x710-4p10GE:
1100 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1101 - ring4 10GE-ports x710-4p10GE:
1102 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1104 - ring1 10GE-ports x710-4p10GE:
1105 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1106 - ring2 10GE-ports x710-4p10GE:
1107 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1108 - ring3 10GE-ports x710-4p10GE:
1109 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1110 - ring4 10GE-ports x710-4p10GE:
1111 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1114 #### 1-Node-Thunderx2 (1n-tx2) WIP
1118 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1119 - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1120 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1121 - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1122 - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1123 - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1126 #### 2-Node-Skylake (2n-skx) PROD
1130 - ring1 10GE-ports x710-4p10GE on SUT:
1131 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1132 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1133 - ring2 10GE-ports x710-4p10GE on SUT:
1134 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1135 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1136 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1137 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1138 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1139 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1140 - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1.
1141 - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2.
1142 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1143 - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
1144 - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
1146 - ring1 10GE-ports x710-4p10GE on SUT:
1147 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1148 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1149 - ring2 10GE-ports x710-4p10GE on SUT:
1150 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1151 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1152 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1153 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1154 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1155 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1156 - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1.
1157 - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2.
1158 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1159 - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
1160 - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
1162 - ring1 10GE-ports x710-4p10GE on SUT:
1163 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1164 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1165 - ring2 10GE-ports x710-4p10GE on SUT:
1166 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1167 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1168 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1169 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1170 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1171 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1172 - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1.
1173 - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2.
1174 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1175 - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
1176 - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
1178 - ring1 10GE-ports x710-4p10GE on SUT:
1179 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1180 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1181 - ring2 10GE-ports x710-4p10GE on SUT:
1182 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1183 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1184 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1185 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1186 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1187 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1188 - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1.
1189 - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2.
1190 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1191 - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
1192 - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
1195 #### 2-Node-Denverton (2n-dnv) TODO
1201 #### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
1205 - link1 10GE-port x710-4p10GE on SUT:
1206 - t25-tg1-p1 to t25-sut1-c2/p1.
1207 - link2 10GE-port x710-4p10GE on SUT:
1208 - t25-tg1-p2 to t25-sut1-c2/p2.
1209 - link3 10GE-port x710-4p10GE on SUT:
1210 - t25-tg1-p3 to t25-sut1-c2/p3.
1211 - link4 10GE-port x710-4p10GE on SUT:
1212 - t25-tg1-p4 to t25-sut1-c2/p4.
1215 #### 3-Node-Haswell (3n-hsw) PROD
1219 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1220 - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1221 - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1222 - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1223 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1224 - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1225 - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1226 - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1227 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1228 - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1229 - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1230 - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1231 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1232 - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1233 - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1234 - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1235 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1236 - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1237 - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1238 - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1239 - TG loopback ports Intel NIC x710 2p10GE
1240 - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1243 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1244 - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1245 - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1246 - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1247 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1248 - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1249 - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1250 - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1251 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1252 - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1253 - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1254 - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1255 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1256 - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1257 - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1258 - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1259 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1260 - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1261 - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1262 - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1263 - TG loopback ports Intel NIC x710 2p10GE
1264 - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1267 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1268 - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1269 - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1270 - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1271 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1272 - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1273 - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1274 - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1275 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1276 - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1277 - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1278 - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1279 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1280 - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1281 - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1282 - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1283 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1284 - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1285 - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1286 - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1287 - TG loopback ports Intel NIC x710 2p10GE
1288 - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1291 #### 3-Node-Skylake (3n-skx) PROD
1295 - ring1 10GE-ports x710-4p10GE on SUTs:
1296 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1297 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1298 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1299 - ring2 10GE-ports x710-4p10GE on SUT:
1300 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1301 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1302 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1303 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1304 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1305 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1306 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1307 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1308 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1309 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1310 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1311 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1312 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1313 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1315 - ring1 10GE-ports x710-4p10GE on SUTs:
1316 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1317 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1318 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1319 - ring2 10GE-ports x710-4p10GE on SUT:
1320 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1321 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1322 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1323 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1324 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1325 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1326 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1327 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1328 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1329 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1330 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1331 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1332 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1333 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1336 #### 3-Node-Rangeley (3n-rng) TODO
1342 #### 3-Node-Taishan (3n-tsh) WIP
1346 - ring1 10GE-ports 82599-2p10GE on SUTs:
1347 - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1348 - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1349 - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1350 - ring2 25GE-ports cx4-2p25GE on SUTs:
1351 - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1352 - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1353 - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1356 #### 3-Node-Mcbin (3n-mcb) WIP
1360 - ring1 10GE-ports Marvell on SUTs:
1361 - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1362 - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1363 - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1371 1. Ixia PerfectStorm One Appliance
1373 - Chassis: PS10GE4NG.
1374 - Motherboard: SuperMicro X11DPG-QT.
1375 - Processors: Quad-Core, Intel Processor.
1376 - HW accelerators: FPGA offload.
1378 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1379 - Physical Interfaces: 4 * 10GE SFP+.
1380 - Operating System: Native IxOS.
1386 1. Arm Cortex A-72 servers
1388 - Chassis: Marvell ThunderX2
1389 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1390 - RAM Memory: 4* 32GB RDIMM
1391 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1392 - 2 * Huawei TaiShan 2280.
1393 - Chassis: Huawei TaiShan 2280.
1394 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1395 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1396 - Disks: 1* 4TB SATA HDD.
1398 - Chassis: MACCHIATObin.
1399 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1400 - RAM Memory: 1* 16GB DDR4.
1401 - Disks: 1* 128GB(?) SATA SDD.
1404 ### Xeon and Atom Servers
1407 1. Intel Xeon servers:
1408 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1409 - Chassis: SuperMicro SYS-7049GP-TRT.
1410 - Motherboard: SuperMicro X11DPG-QT.
1411 - Processors: 2* Intel Platinum 8180 2.3 GHz.
1412 - RAM Memory: 16* 16GB DDR4-2666MHz.
1413 - Disks: 2* 1.6TB 6G SATA SSD.
1414 2. Intel Atom servers with Rangely processors.
1415 - 3 * Netgate XG-2758-1u
1416 - Chassis: Netgate XG-2758-1u
1417 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1418 - RAM Memory: 16GB ECC
1422 ### Network Interface Cards
1426 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1427 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1428 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1430 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1432 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1434 - 4 * mcx556a-edat NICs (not on site yet, in transit)
1437 ### Pluggables and Cables
1443 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1444 - 80 * 10G SR optic (generic, "Intel" compatible branded)
1450 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)