ebc14789e6a351d8d803c818d5762462ddef94ad
[csit.git] / docs / report / vpp_performance_tests / overview.rst
1 Overview
2 ========
3
4 Tested Physical Topologies
5 --------------------------
6
7 CSIT VPP performance tests are executed on physical baremetal servers hosted by
8 LF FD.io project. Testbed physical topology is shown in the figure below.
9
10 ::
11
12     +------------------------+           +------------------------+
13     |                        |           |                        |
14     |  +------------------+  |           |  +------------------+  |
15     |  |                  |  |           |  |                  |  |
16     |  |                  <----------------->                  |  |
17     |  |       DUT1       |  |           |  |       DUT2       |  |
18     |  +--^---------------+  |           |  +---------------^--+  |
19     |     |                  |           |                  |     |
20     |     |            SUT1  |           |  SUT2            |     |
21     +------------------------+           +------------------^-----+
22           |                                                 |
23           |                                                 |
24           |                  +-----------+                  |
25           |                  |           |                  |
26           +------------------>    TG     <------------------+
27                              |           |
28                              +-----------+
29
30 SUT1 and SUT2 are two System Under Test servers (Cisco UCS C240, each with two
31 Intel XEON CPUs), TG is a Traffic Generator (TG, another Cisco UCS C240, with
32 two Intel XEON CPUs). SUTs run VPP SW application in Linux user-mode as a
33 Device Under Test (DUT). TG runs TRex SW application as a packet Traffic
34 Generator. Physical connectivity between SUTs and to TG is provided using
35 different NIC models that need to be tested for performance. Currently
36 installed and tested NIC models include:
37
38 #. 2port10GE X520-DA2 Intel.
39 #. 2port10GE X710 Intel.
40 #. 2port10GE VIC1227 Cisco.
41 #. 2port40GE VIC1385 Cisco.
42 #. 2port40GE XL710 Intel.
43
44 From SUT and DUT perspective, all performance tests involve forwarding packets
45 between two physical Ethernet ports (10GE or 40GE). Due to the number of
46 listed NIC models tested and available PCI slot capacity in SUT servers, in
47 all of the above cases both physical ports are located on the same NIC. In
48 some test cases this results in measured packet throughput being limited not
49 by VPP DUT but by either the physical interface or the NIC capacity.
50
51 Going forward CSIT project will be looking to add more hardware into FD.io
52 performance labs to address larger scale multi-interface and multi-NIC
53 performance testing scenarios.
54
55 For test cases that require DUT (VPP) to communicate with
56 VirtualMachines(VMs)/LinuxContainers(LXCs) over vhost-user/memif
57 interfaces, N of VM/LXC instances are created on SUT1 and SUT2. For N=1
58 DUT forwards packets between vhost/memif and physical interfaces. For
59 N>1 DUT a logical service chain forwarding topology is created on DUT by
60 applying L2 or IPv4/IPv6 configuration depending on the test suite. DUT
61 test topology with N VM/LXC instances is shown in the figure below
62 including applicable packet flow thru the DUTs and VMs/LXCs (marked in
63 the figure with ``***``).
64
65 ::
66
67     +-------------------------+           +-------------------------+
68     | +---------+ +---------+ |           | +---------+ +---------+ |
69     | |VM/LXC[1]| |VM/LXC[N]| |           | |VM/LXC[1]| |VM/LXC[N]| |
70     | |  *****  | |  *****  | |           | |  *****  | |  *****  | |
71     | +--^---^--+ +--^---^--+ |           | +--^---^--+ +--^---^--+ |
72     |   *|   |*     *|   |*   |           |   *|   |*     *|   |*   |
73     | +--v---v-------v---v--+ |           | +--v---v-------v---v--+ |
74     | |  *   *       *   *  |*|***********|*|  *   *       *   *  | |
75     | |  *   *********   ***<-|-----------|->***   *********   *  | |
76     | |  *    DUT1          | |           | |       DUT2       *  | |
77     | +--^------------------+ |           | +------------------^--+ |
78     |   *|                    |           |                    |*   |
79     |   *|            SUT1    |           |  SUT2              |*   |
80     +-------------------------+           +-------------------------+
81         *|                                                     |*
82         *|                                                     |*
83         *|                    +-----------+                    |*
84         *|                    |           |                    |*
85         *+-------------------->    TG     <--------------------+*
86         **********************|           |**********************
87                               +-----------+
88
89 For VM/LXC tests, packets are switched by DUT multiple times: twice for
90 a single VM/LXC, three times for two VMs/LXCs, N+1 times for N VMs/LXCs.
91 Hence the external throughput rates measured by TG and listed in this
92 report must be multiplied by (N+1) to represent the actual DUT aggregate
93 packet forwarding rate.
94
95 Note that reported DUT (VPP) performance results are specific to the
96 SUTs tested. Current LF FD.io SUTs are based on Intel XEON E5-2699v3
97 2.3GHz CPUs. SUTs with other CPUs are likely to yield different results.
98 A good rule of thumb, that can be applied to estimate VPP packet
99 thoughput for Phy-to-Phy (NIC-to-NIC, PCI-to-PCI) topology, is to expect
100 the forwarding performance to be proportional to CPU core frequency,
101 assuming CPU is the only limiting factor and all other SUT parameters
102 equivalent to FD.io CSIT environment. The same rule of thumb can be also
103 applied for Phy-to-VM/LXC-to-Phy (NIC-to-VM/LXC-to-NIC) topology, but
104 due to much higher dependency on intensive memory operations and
105 sensitivity to Linux kernel scheduler settings and behaviour, this
106 estimation may not always yield good enough accuracy.
107
108 For detailed LF FD.io test bed specification and physical topology
109 please refer to
110 `LF FD.io CSIT testbed wiki page <https://wiki.fd.io/view/CSIT/CSIT_LF_testbed>`_.
111
112 Performance Tests Coverage
113 --------------------------
114
115 Performance tests are split into the two main categories:
116
117 - Throughput discovery - discovery of packet forwarding rate using binary search
118   in accordance to RFC2544.
119
120   - NDR - discovery of Non Drop Rate packet throughput, at zero packet loss;
121     followed by one-way packet latency measurements at 10%, 50% and 100% of
122     discovered NDR throughput.
123   - PDR - discovery of Partial Drop Rate, with specified non-zero packet loss
124     currently set to 0.5%; followed by one-way packet latency measurements at
125     100% of discovered PDR throughput.
126
127 - Throughput verification - verification of packet forwarding rate against
128   previously discovered throughput rate. These tests are currently done against
129   0.9 of reference NDR, with reference rates updated periodically.
130
131 CSIT |release| includes following performance test suites, listed per NIC type:
132
133 - 2port10GE X520-DA2 Intel
134
135   - **L2XC** - L2 Cross-Connect switched-forwarding of untagged, dot1q, dot1ad
136     VLAN tagged Ethernet frames.
137   - **L2BD** - L2 Bridge-Domain switched-forwarding of untagged Ethernet frames
138     with MAC learning; disabled MAC learning i.e. static MAC tests to be added.
139   - **IPv4** - IPv4 routed-forwarding.
140   - **IPv6** - IPv6 routed-forwarding.
141   - **IPv4 Scale** - IPv4 routed-forwarding with 20k, 200k and 2M FIB entries.
142   - **IPv6 Scale** - IPv6 routed-forwarding with 20k, 200k and 2M FIB entries.
143   - **VMs with vhost-user** - virtual topologies with 1 VM and service chains
144     of 2 VMs using vhost-user interfaces, with VPP forwarding modes incl. L2
145     Cross-Connect, L2 Bridge-Domain, VXLAN with L2BD, IPv4 routed-forwarding.
146   - **COP** - IPv4 and IPv6 routed-forwarding with COP address security.
147   - **iACL** - IPv4 and IPv6 routed-forwarding with iACL address security.
148   - **LISP** - LISP overlay tunneling for IPv4-over-IPv4, IPv6-over-IPv4,
149     IPv6-over-IPv6, IPv4-over-IPv6 in IPv4 and IPv6 routed-forwarding modes.
150   - **VXLAN** - VXLAN overlay tunnelling integration with L2XC and L2BD.
151   - **QoS Policer** - ingress packet rate measuring, marking and limiting
152     (IPv4).
153   - **CGNAT** - Carrier Grade Network Address Translation tests with varying
154     number of users and ports per user.
155
156 - 2port40GE XL710 Intel
157
158   - **L2XC** - L2 Cross-Connect switched-forwarding of untagged Ethernet frames.
159   - **L2BD** - L2 Bridge-Domain switched-forwarding of untagged Ethernet frames
160     with MAC learning.
161   - **IPv4** - IPv4 routed-forwarding.
162   - **IPv6** - IPv6 routed-forwarding.
163   - **VMs with vhost-user** - virtual topologies with 1 VM and service chains
164     of 2 VMs using vhost-user interfaces, with VPP forwarding modes incl. L2
165     Cross-Connect, L2 Bridge-Domain, VXLAN with L2BD, IPv4 routed-forwarding.
166   - **IPSec** - IPSec encryption with AES-GCM, CBC-SHA1 ciphers, in combination
167     with IPv4 routed-forwarding.
168   - **IPSec+LISP** - IPSec encryption with CBC-SHA1 ciphers, in combination
169     with LISP-GPE overlay tunneling for IPv4-over-IPv4.
170
171 - 2port10GE X710 Intel
172
173   - **L2BD** - L2 Bridge-Domain switched-forwarding of untagged Ethernet frames
174     with MAC learning.
175   - **VMs with vhost-user** - virtual topologies with 1 VM using vhost-user
176     interfaces, with VPP forwarding modes incl. L2 Bridge-Domain.
177
178 - 2port10GE VIC1227 Cisco
179
180   - **L2BD** - L2 Bridge-Domain switched-forwarding of untagged Ethernet frames
181     with MAC learning.
182
183 - 2port40GE VIC1385 Cisco
184
185   - **L2BD** - L2 Bridge-Domain switched-forwarding of untagged Ethernet frames
186      with MAC learning.
187
188 Execution of performance tests takes time, especially the throughput discovery
189 tests. Due to limited HW testbed resources available within FD.io labs hosted
190 by Linux Foundation, the number of tests for NICs other than X520 (a.k.a.
191 Niantic) has been limited to few baseline tests. Over time we expect the HW
192 testbed resources to grow, and will be adding complete set of performance
193 tests for all models of hardware to be executed regularly and(or)
194 continuously.
195
196 Performance Tests Naming
197 ------------------------
198
199 CSIT |release| follows a common structured naming convention for all
200 performance and system functional tests, introduced in CSIT |release-1|.
201
202 The naming should be intuitive for majority of the tests. Complete
203 description of CSIT test naming convention is provided on `CSIT test naming wiki
204 <https://wiki.fd.io/view/CSIT/csit-test-naming>`_.
205
206 Here few illustrative examples of the new naming usage for performance test
207 suites:
208
209 #. **Physical port to physical port - a.k.a. NIC-to-NIC, Phy-to-Phy, P2P**
210
211    - *PortNICConfig-WireEncapsulation-PacketForwardingFunction-
212      PacketProcessingFunction1-...-PacketProcessingFunctionN-TestType*
213    - *10ge2p1x520-dot1q-l2bdbasemaclrn-ndrdisc.robot* => 2 ports of 10GE on
214      Intel x520 NIC, dot1q tagged Ethernet, L2 bridge-domain baseline switching
215      with MAC learning, NDR throughput discovery.
216    - *10ge2p1x520-ethip4vxlan-l2bdbasemaclrn-ndrchk.robot* => 2 ports of 10GE
217      on Intel x520 NIC, IPv4 VXLAN Ethernet, L2 bridge-domain baseline
218      switching with MAC learning, NDR throughput discovery.
219    - *10ge2p1x520-ethip4-ip4base-ndrdisc.robot* => 2 ports of 10GE on Intel
220      x520 NIC, IPv4 baseline routed forwarding, NDR throughput discovery.
221    - *10ge2p1x520-ethip6-ip6scale200k-ndrdisc.robot* => 2 ports of 10GE on
222      Intel x520 NIC, IPv6 scaled up routed forwarding, NDR throughput
223      discovery.
224
225 #. **Physical port to VM (or VM chain) to physical port - a.k.a. NIC2VM2NIC,
226    P2V2P, NIC2VMchain2NIC, P2V2V2P**
227
228    - *PortNICConfig-WireEncapsulation-PacketForwardingFunction-
229      PacketProcessingFunction1-...-PacketProcessingFunctionN-VirtEncapsulation-
230      VirtPortConfig-VMconfig-TestType*
231    - *10ge2p1x520-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-ndrdisc.robot* => 2 ports
232      of 10GE on Intel x520 NIC, dot1q tagged Ethernet, L2 bridge-domain
233      switching to/from two vhost interfaces and one VM, NDR throughput
234      discovery.
235    - *10ge2p1x520-ethip4vxlan-l2bdbasemaclrn-eth-2vhost-1vm-ndrdisc.robot* => 2
236      ports of 10GE on Intel x520 NIC, IPv4 VXLAN Ethernet, L2 bridge-domain
237      switching to/from two vhost interfaces and one VM, NDR throughput
238      discovery.
239    - *10ge2p1x520-ethip4vxlan-l2bdbasemaclrn-eth-4vhost-2vm-ndrdisc.robot* => 2
240      ports of 10GE on Intel x520 NIC, IPv4 VXLAN Ethernet, L2 bridge-domain
241      switching to/from four vhost interfaces and two VMs, NDR throughput
242      discovery.
243
244 Methodology: Multi-Thread and Multi-Core
245 ----------------------------------------
246
247 **HyperThreading** - CSIT |release| performance tests are executed with SUT
248 servers' Intel XEON CPUs configured in HyperThreading Disabled mode (BIOS
249 settings). This is the simplest configuration used to establish baseline
250 single-thread single-core SW packet processing and forwarding performance.
251 Subsequent releases of CSIT will add performance tests with Intel
252 HyperThreading Enabled (requires BIOS settings change and hard reboot).
253
254 **Multi-core Test** - CSIT |release| multi-core tests are executed in the
255 following VPP thread and core configurations:
256
257 #. 1t1c - 1 VPP worker thread on 1 CPU physical core.
258 #. 2t2c - 2 VPP worker threads on 2 CPU physical cores.
259
260 Note that in quite a few test cases running VPP on 2 physical cores hits
261 the tested NIC I/O bandwidth or packets-per-second limit.
262
263 Methodology: Packet Throughput
264 ------------------------------
265
266 Following values are measured and reported for packet throughput tests:
267
268 - NDR binary search per RFC2544:
269
270   - Packet rate: "RATE: <aggregate packet rate in packets-per-second> pps
271     (2x <per direction packets-per-second>)"
272   - Aggregate bandwidth: "BANDWIDTH: <aggregate bandwidth in Gigabits per
273     second> Gbps (untagged)"
274
275 - PDR binary search per RFC2544:
276
277   - Packet rate: "RATE: <aggregate packet rate in packets-per-second> pps (2x
278     <per direction packets-per-second>)"
279   - Aggregate bandwidth: "BANDWIDTH: <aggregate bandwidth in Gigabits per
280     second> Gbps (untagged)"
281   - Packet loss tolerance: "LOSS_ACCEPTANCE <accepted percentage of packets
282     lost at PDR rate>""
283
284 - NDR and PDR are measured for the following L2 frame sizes:
285
286   - IPv4: 64B, IMIX_v4_1 (28x64B,16x570B,4x1518B), 1518B, 9000B.
287   - IPv6: 78B, 1518B, 9000B.
288
289
290 Methodology: Packet Latency
291 ---------------------------
292
293 TRex Traffic Generator (TG) is used for measuring latency of VPP DUTs. Reported
294 latency values are measured using following methodology:
295
296 - Latency tests are performed at 10%, 50% of discovered NDR rate (non drop rate)
297   for each NDR throughput test and packet size (except IMIX).
298 - TG sends dedicated latency streams, one per direction, each at the rate of
299   10kpps at the prescribed packet size; these are sent in addition to the main
300   load streams.
301 - TG reports min/avg/max latency values per stream direction, hence two sets
302   of latency values are reported per test case; future release of TRex is
303   expected to report latency percentiles.
304 - Reported latency values are aggregate across two SUTs due to three node
305   topology used for all performance tests; for per SUT latency, reported value
306   should be divided by two.
307 - 1usec is the measurement accuracy advertised by TRex TG for the setup used in
308   FD.io labs used by CSIT project.
309 - TRex setup introduces an always-on error of about 2*2usec per latency flow -
310   additonal Tx/Rx interface latency induced by TRex SW writing and reading
311   packet timestamps on CPU cores without HW acceleration on NICs closer to the
312   interface line.
313
314
315 Methodology: KVM VM vhost
316 -------------------------
317
318 CSIT |release| introduced environment configuration changes to KVM Qemu vhost-
319 user tests in order to more representatively measure |vpp-release| performance
320 in configurations with vhost-user interfaces and VMs.
321
322 Current setup of CSIT FD.io performance lab is using tuned settings for more
323 optimal performance of KVM Qemu:
324
325 - Qemu virtio queue size has been increased from default value of 256 to 1024
326   descriptors.
327 - Adjusted Linux kernel CFS scheduler settings, as detailed on this CSIT wiki
328   page: https://wiki.fd.io/view/CSIT/csit-perf-env-tuning-ubuntu1604.
329
330 Adjusted Linux kernel CFS settings make the NDR and PDR throughput performance
331 of VPP+VM system less sensitive to other Linux OS system tasks by reducing
332 their interference on CPU cores that are designated for critical software
333 tasks under test, namely VPP worker threads in host and Testpmd threads in
334 guest dealing with data plan.
335
336 Methodology: IPSec with Intel QAT HW cards
337 ------------------------------------------
338
339 VPP IPSec performance tests are using DPDK cryptodev device driver in
340 combination with HW cryptodev devices - Intel QAT 8950 50G - present in
341 LF FD.io physical testbeds. DPDK cryptodev can be used for all IPSec
342 data plane functions supported by VPP.
343
344 Currently CSIT |release| implements following IPSec test cases:
345
346 - AES-GCM, CBC-SHA1 ciphers, in combination with IPv4 routed-forwarding
347   with Intel xl710 NIC.
348 - CBC-SHA1 ciphers, in combination with LISP-GPE overlay tunneling for
349   IPv4-over-IPv4 with Intel xl710 NIC.
350
351 Methodology: TRex Traffic Generator Usage
352 -----------------------------------------
353
354 The `TRex traffic generator <https://wiki.fd.io/view/TRex>`_ is used for all
355 CSIT performance tests. TRex stateless mode is used to measure NDR and PDR
356 throughputs using binary search (NDR and PDR discovery tests) and for quick
357 checks of DUT performance against the reference NDRs (NDR check tests) for
358 specific configuration.
359
360 TRex is installed and run on the TG compute node. The typical procedure is:
361
362 - If the TRex is not already installed on TG, it is installed in the
363   suite setup phase - see `TRex intallation`_.
364 - TRex configuration is set in its configuration file
365   ::
366
367   /etc/trex_cfg.yaml
368
369 - TRex is started in the background mode
370   ::
371
372   $ sh -c 'cd /opt/trex-core-2.25/scripts/ && sudo nohup ./t-rex-64 -i -c 7 --iom 0 > /dev/null 2>&1 &' > /dev/null
373
374 - There are traffic streams dynamically prepared for each test. The traffic
375   is sent and the statistics obtained using trex_stl_lib.api.STLClient.
376
377 **Measuring packet loss**
378
379 - Create an instance of STLClient
380 - Connect to the client
381 - Add all streams
382 - Clear statistics
383 - Send the traffic for defined time
384 - Get the statistics
385
386 If there is a warm-up phase required, the traffic is sent also before test and
387 the statistics are ignored.
388
389 **Measuring latency**
390
391 If measurement of latency is requested, two more packet streams are created (one
392 for each direction) with TRex flow_stats parameter set to STLFlowLatencyStats. In
393 that case, returned statistics will also include min/avg/max latency values.