-## FD.io CSIT Testbeds - Xeon Haswell
-
-This is a low-level design implemented as an original FD.io CSIT lab based on
-Cisco UCS-c240m4 servers based on Intel Xeon Haswell processors.
-
-### Server Hardware Configuration
-
-Total of 10 Cisco UCS-c240 servers with Intel Xeon Haswell processors have been
-used to built FD.io CSIT 3-Node Haswell (3n-hsw) performance testbeds and VIRL
-functional testbeds. Following three HW configuration types of UCS x86 servers
-are used:
-
-```
- 1. Type-1: Purpose - VPP functional and performance conformance testing.
-    - Quantity: 6 computers as SUT hosts (Systems Under Test).
-    - Physical connectivity:
-        - CIMC and host management ports.
-        - NIC ports connected in 3-node topologies.
-    - Main HW configuration:
-        - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
-        - Processors: 2* E5-2699v3 2.3 GHz.
-        - RAM Memory: 16* 32GB DDR4-2133MHz.
-        - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
-    - NICs configuration:
-        - Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
-            - PCIe Slot1: Cisco VIC 1385 2p40GE.
-            - PCIe Slot2: Intel NIC x520 2p10GE.
-            - PCIe Slot3: empty.
-        - Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
-            - PCIe Slot4: Intel NIC xl710 2p40GE.
-            - PCIe Slot5: Intel NIC x710 2p10GE.
-            - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
-        - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
- 2. Type-2: Purpose - VPP functional and performance conformance testing.
-    - Quantity: 3 computers as TG hosts (Traffic Generators).
-    - Physical connectivity:
-        - CIMC and host management ports.
-        - NIC ports connected in 3-node topologies.
-    - Main HW configuration:
-        - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
-        - Processors: 2* E5-2699v3 2.3 GHz.
-        - RAM Memory: 16* 32GB DDR4-2133MHz.
-        - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
-    - NICs configuration:
-        - Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
-            - PCIe Slot1: Intel NIC xl710 2p40GE.
-            - PCIe Slot2: Intel NIC x710 2p10GE.
-            - PCIe Slot3: Intel NIC x710 2p10GE.
-        - Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
-            - PCIe Slot4: Intel NIC xl710 2p40GE.
-            - PCIe Slot5: Intel NIC x710 2p10GE.
-            - PCIe Slot6: Intel NIC x710 2p10GE.
-        - MLOM slot: empty.
- 3. Type-3: Purpose - VIRL functional conformance.
-    - Quantity: 3 computers as VIRL hosts.
-    - Physical connectivity:
-        - CIMC and host management ports.
-        - no NIC ports, standalone setup.
-    - Main HW configuration:
-        - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
-        - Processors: 2* E5-2699v3 2.3 GHz.
-        - RAM Memory: 16* 32GB DDR4-2133MHz.
-        - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
-    - NICs configuration:
-        - Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
-            - no cards.
-        - Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
-            - no cards.
-        - MLOM slot: empty.
-```
-
-## Testbeds1,2,3 Connectivity
-
-### Management Ports
-
-Total of 10 UCSC-C240-M4SX servers is made available for FD.IO CSIT testbed. For
-management purposes, each server must have following two ports connected to the
-management network:
-
-```
- 1. 1GE CIMC port
-    - CIMC - Cisco Integrated Management Controller.
-    - Required for provides embedded server management with WebUI, CLI, SNMPv3,
-      IPMIv2.0.
- 2. 1GE management port
-    - hostOS management port.
-```
-
-### Naming Convention
-
-Following naming convention is used within this page to specify physical
-connectivity and wiring across defined CSIT testbeds:
-
-```
- - testbedname: testbedN.
- - hostname:
-    - traffic-generator: tN-tgW.
-    - system-under-testX: tN-sutX.
- - portnames:
-    - tN-tgW-cY/pZ.
-    - tN-sutX-cY/pZ.
- - where:
-    - N - testbed number.
-    - tgW - server acts as traffic-generator with W index.
-    - sutX - server acts as system-under-test with X index.
-    - Y - PCIe slot number denoting a NIC card number within the host.
-        - Y=1,2,3 - slots in Riser 1, Right PCIe Riser Board, NUMA node 0.
-        - Y=4,5,6 - slots in Riser 2, Left PCIe Riser Board, NUMA node 1.
-        - Y=m - the MLOM slot.
-    - Z - port number on the NIC card.
-```
-
-### 3-node Topology Testbeds for Performance
-
-Nine servers are used to build three of 3-node topologies, with each topology
-using two servers of Type-1 (SUT function) and one server of Type-2
-(TG function). Server NIC cards are placed and NIC ports are connected using the
-scheme defined in next sections.
-
-### LOM (CIMC) and Management networks
-
-Each server has a LOM (Lights-Out-Management e.g. Cisco CIMC) and a Management
-port, which are connected to two different VLANs.
-
-```
- 1. LOM (CIMC) VLAN:
-    - Subnet: 10.30.50.0/24
-    - Gateway: 10.30.50.1
-    - Broadcast: 10.30.50.255
-    - DNS1: 199.204.44.24
-    - DNS2: 199.204.47.54
- 2. Management Vlan:
-    - Subnet: 10.30.51.0/24
-    - Gateway: 10.30.51.1
-    - Broadcast: 10.30.51.255
-    - DNS1: 199.204.44.24
-    - DNS2: 199.204.47.54
-```
-To access these hosts, an VPN connection is required.
-
-#### LOM (CIMC) VLAN IP Addresses allocation
-
-Name | Comment
----- | -------
-10.30.50.0 | network
-10.30.51.1 | Router
-10.30.50.2 | LF Reserved
-10.30.50.3 | LF Reserved
-10.30.50.4 | LF Reserved
-10.30.50.5 | LF Reserved
-10.30.50.6 | LF Reserved
-10.30.50.7 | LF Reserved
-10.30.50.8 | LF Reserved
-10.30.50.9 | LF Reserved
-10.30.50.10 | LF Reserved
-10.30.50.11 | LF Reserved
-10.30.50.12 | LF Reserved
-10.30.50.13 | LF Reserved
-10.30.50.14 | LF Reserved
-10.30.50.15 | LF Reserved
-10.30.50.16 | t1-tg1
-10.30.50.17 | t1-sut1
-10.30.50.18 | t1-sut2
-10.30.50.20 | t2-tg1
-10.30.50.21 | t2-sut1
-10.30.50.22 | t2-sut2
-10.30.50.24 | t3-tg1
-10.30.50.25 | t3-sut1
-10.30.50.26 | t3-sut-2
-10.30.50.28 | t4-sut1
-10.30.50.29 | t4-sut2
-10.30.50.30 | t4-sut3
-10.30.50.255 | Broadcast
-
-#### Management VLAN IP Addresses allocation
-
-Name | Comment
----- | -------
-10.30.51.0 | network
-10.30.51.1 | Router
-10.30.51.2 | LF Reserved
-10.30.51.3 | LF Reserved
-10.30.51.4 | LF Reserved
-10.30.51.5 | LF Reserved
-10.30.51.6 | LF Reserved
-10.30.51.7 | LF Reserved
-10.30.51.8 | LF Reserved
-10.30.51.9 | netgate-1
-10.30.51.10 | netgate-2
-10.30.51.11 | netgate-3
-10.30.51.12 | softiron-1
-10.30.51.13 | softiron-2
-10.30.51.14 | softiron-3
-10.30.51.15 | LF Reserved
-10.30.51.16 | t1-tg1
-10.30.51.17 | t1-sut1
-10.30.51.18 | t1-sut2
-10.30.51.20 | t2-tg1
-10.30.51.21 | t2-sut1
-10.30.51.22 | t2-sut2
-10.30.51.24 | t3-tg1
-10.30.51.25 | t3-sut1
-10.30.51.26 | t3-sut-2
-10.30.51.28 | t4-sut1
-10.30.51.29 | t4-sut2
-10.30.51.30 | t4-sut3
-10.30.51.31-10.30.51.105 | VIRL1
-10.30.51.106-10.30.51.180 | VIRL2
-10.30.51.181-10.30.51.254 | VIRL3
-10.30.51.255 | Broadcast
-
-### Testbeds1,2,3 Naming: Servers, Ports
-
-Each server in 3-node Topology has its NIC cards placed, and NIC cards and ports
-indexed using defined naming convention:
-
-```
- 1. Server1 of Type-1:
-    - testbedname: testbed1.
-    - hostname: t1-sut1.
-    - CIMC IP: 10.30.50.17
-    - Host IP: 10.30.51.17
-    - portnames:
-        - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 2. Server2 of Type-1:
-    - testbedname: testbed1.
-    - hostname: t1-sut2.
-    - CIMC IP: 10.30.50.18
-    - Host IP: 10.30.51.18
-    - portnames:
-        - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 3. Server3 of Type-2:
-    - testbedname: testbed1.
-    - hostname: t1-tg1.
-    - CIMC IP: 10.30.50.16
-    - Host IP: 10.30.51.16
-    - portnames:
-        - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 4. Server4 of Type-1:
-    - testbedname: testbed2.
-    - hostname: t2-sut1.
-    - CIMC IP: 10.30.50.21
-    - Host IP: 10.30.51.21
-    - portnames:
-        - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 5. Server5 of Type-1:
-    - testbedname: testbed2.
-    - hostname: t2-sut2.
-    - CIMC IP: 10.30.50.22
-    - Host IP: 10.30.51.22
-    - portnames:
-        - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 6. Server6 of Type-2:
-    - testbedname: testbed2.
-    - hostname: t2-tg1.
-    - CIMC IP: 10.30.50.20
-    - Host IP: 10.30.51.20
-    - portnames:
-        - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 7. Server7 of Type-1:
-    - testbedname: testbed3.
-    - hostname: t3-sut1.
-    - CIMC IP: 10.30.50.25
-    - Host IP: 10.30.51.25
-    - portnames:
-        - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 8. Server8 of Type-1:
-    - testbedname: testbed3.
-    - hostname: t3-sut2.
-    - CIMC IP: 10.30.50.26
-    - Host IP: 10.30.51.26
-    - portnames:
-        - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 9. Server9 of Type-2:
-    - testbedname: testbed3.
-    - hostname: t3-tg1.
-    - CIMC IP: 10.30.50.24
-    - Host IP: 10.30.51.24
-    - portnames:
-        - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-```
-
-### Testbeds1,2,3 Network Connectivity
-
-Listed nine servers are connected into the three of 3-node testbeds, testbed1,
-testbed2 and testbed3, using defined naming convention as follows:
-
-```
- 1. testbed1:
-    - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
-        - t1-tg1-c1/p1 to t1-sut1-c1/p2.
-        - t1-sut1-c1/p1 to t1-sut2-c1/p2.
-        - t1-sut2-c1/p1 to t1-tg1-c1/p2.
-    - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
-        - t1-tg1-c2/p1 to t1-sut1-c2/p2.
-        - t1-sut1-c2/p1 to t1-sut2-c2/p2.
-        - t1-sut2-c2/p1 to t1-tg1-c2/p2.
-    - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
-        - t1-tg1-c4/p1 to t1-sut1-c4/p2.
-        - t1-sut1-c4/p1 to t1-sut2-c4/p2.
-        - t1-sut2-c4/p1 to t1-tg1-c4/p2.
-    - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
-        - t1-tg1-c5/p1 to t1-sut1-c5/p2.
-        - t1-sut1-c5/p1 to t1-sut2-c5/p2.
-        - t1-sut2-c5/p1 to t1-tg1-c5/p2.
-    - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
-        - t1-tg1-c2/p1 to t1-sut1-cm/p2.
-        - t1-sut1-cm/p1 to t1-sut2-cm/p2.
-        - t1-sut2-cm/p1 to t1-tg1-c2/p2.
-    - TG loopback ports Intel NIC x710 2p10GE
-        - t1-tg1-c6/p1 to t1-tg1-c6/p2.
-
- 2. testbed2:
-    - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
-        - t2-tg1-c1/p1 to t2-sut1-c1/p2.
-        - t2-sut1-c1/p1 to t2-sut2-c1/p2.
-        - t2-sut2-c1/p1 to t2-tg1-c1/p2.
-    - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
-        - t2-tg1-c2/p1 to t2-sut1-c2/p2.
-        - t2-sut1-c2/p1 to t2-sut2-c2/p2.
-        - t2-sut2-c2/p1 to t2-tg1-c2/p2.
-    - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
-        - t2-tg1-c4/p1 to t2-sut1-c4/p2.
-        - t2-sut1-c4/p1 to t2-sut2-c4/p2.
-        - t2-sut2-c4/p1 to t2-tg1-c4/p2.
-    - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
-        - t2-tg1-c5/p1 to t2-sut1-c5/p2.
-        - t2-sut1-c5/p1 to t2-sut2-c5/p2.
-        - t2-sut2-c5/p1 to t2-tg1-c5/p2.
-    - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
-        - t2-tg1-c2/p1 to t2-sut1-cm/p2.
-        - t2-sut1-cm/p1 to t2-sut2-cm/p2.
-        - t2-sut2-cm/p1 to t2-tg1-c2/p2.
-    - TG loopback ports Intel NIC x710 2p10GE
-        - t2-tg1-c6/p1 to t2-tg1-c6/p2.
-
- 3. testbed3:
-    - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
-        - t3-tg1-c1/p1 to t3-sut1-c1/p2.
-        - t3-sut1-c1/p1 to t3-sut2-c1/p2.
-        - t3-sut2-c1/p1 to t3-tg1-c1/p2.
-    - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
-        - t3-tg1-c2/p1 to t3-sut1-c2/p2.
-        - t3-sut1-c2/p1 to t3-sut2-c2/p2.
-        - t3-sut2-c2/p1 to t3-tg1-c2/p2.
-    - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
-        - t3-tg1-c4/p1 to t3-sut1-c4/p2.
-        - t3-sut1-c4/p1 to t3-sut2-c4/p2.
-        - t3-sut2-c4/p1 to t3-tg1-c4/p2.
-    - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
-        - t3-tg1-c5/p1 to t3-sut1-c5/p2.
-        - t3-sut1-c5/p1 to t3-sut2-c5/p2.
-        - t3-sut2-c5/p1 to t3-tg1-c5/p2.
-    - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
-        - t3-tg1-c2/p1 to t3-sut1-cm/p2.
-        - t3-sut1-cm/p1 to t3-sut2-cm/p2.
-        - t3-sut2-cm/p1 to t3-tg1-c2/p2.
-    - TG loopback ports Intel NIC x710 2p10GE
-        - t3-tg1-c6/p1 to t3-tg1-c6/p2.
-```
-
-## Testbeds1,2,3 Server Specifications
-
-### Linux lscpu
-
-```
- $ lscpu
- Architecture:          x86_64
- CPU op-mode(s):        32-bit, 64-bit
- Byte Order:            Little Endian
- CPU(s):                36
- On-line CPU(s) list:   0-35
- Thread(s) per core:    1
- Core(s) per socket:    18
- Socket(s):             2
- NUMA node(s):          2
- Vendor ID:             GenuineIntel
- CPU family:            6
- Model:                 63
- Model name:            Intel(R) Xeon(R) CPU E5-2699 v3 @ 2.30GHz
- Stepping:              2
- CPU MHz:               2294.249
- BogoMIPS:              4589.82
- Virtualization:        VT-x
- L1d cache:             32K
- L1i cache:             32K
- L2 cache:              256K
- L3 cache:              46080K
- NUMA node0 CPU(s):     0-17
- NUMA node1 CPU(s):     18-35
- Flags:                 fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx pdpe1gb rdtscp lm constant_tsc arch_perfmon pebs bts rep_good nopl xtopology nonstop_tsc aperfmperf eagerfpu pni pclmulqdq
- dtes64 monitor ds_cpl vmx smx est tm2 ssse3 sdbg fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt tsc_deadline_timer aes xsave avx f16c rdrand lahf_lm abm epb tpr_shadow vnmi flexpriority ept vpid fsgsbase tsc_adjust bmi1 avx2 smep bmi2 erms invpcid cqm xsaveopt
- cqm_llc cqm_occup_llc dtherm arat pln pts
-```
-
-### Linux dmidecode pci
-
-```
- $ dmidecode --type 9 | grep 'Handle\|Slot\|Type\|Address'
- Handle 0x0046, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:1
-     Type: x8 PCI Express 3 x8
-     Bus Address: 0000:0a:02.0
- Handle 0x0047, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:2
-     Type: x8 PCI Express 3 x8
-     Bus Address: 0000:0e:03.2
- Handle 0x0048, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:3
-     Type: x8 PCI Express 3 x8
-     Bus Address: 0000:0d:03.0
- Handle 0x0049, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:4
-     Type: x8 PCI Express 3 x8
-     Bus Address: 0000:85:02.2
- Handle 0x004A, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:5
-     Type: x8 PCI Express 3 x16
-     Bus Address: 0000:87:03.0
- Handle 0x004B, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:6
-     Type: x8 PCI Express 3 x8
-     Bus Address: 0000:84:02.0
- Handle 0x004C, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:MLOM
-     Type: x8 Other
-     Bus Address: 0000:01:01.0
- Handle 0x004D, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:HBA
-     Type: x8 Other
-     Bus Address: 0000:0c:02.2
- Handle 0x004E, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:NVMe1
-     Type: x4 PCI Express 3 x4
-     Bus Address: 0000:82:01.0
- Handle 0x004F, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:NVMe2
-     Type: x4 PCI Express 3 x4
-     Bus Address: 0000:83:01.1
- Handle 0x0050, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:2.1
-     Type: x16 PCI Express 3 x16
-     Bus Address: 0000:00:1f.7
- Handle 0x0051, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:2.2
-     Type: x16 PCI Express 3 x16
-     Bus Address: 0000:00:1f.7
- Handle 0x0052, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:2.3
-     Type: x16 PCI Express 3 x16
-     Bus Address: 0000:00:1f.7
- Handle 0x0053, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:2.4
-     Type: x16 PCI Express 3 x16
-     Bus Address: 0000:00:1f.7
- Handle 0x0054, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:2.5
-     Type: x16 PCI Express 3 x16
-     Bus Address: 0000:00:1f.7
- Handle 0x0055, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:5.1
-     Type: x8 PCI Express 3 x16
-     Bus Address: 0000:00:1f.7
- Handle 0x0056, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:5.2
-     Type: x8 PCI Express 3 x16
-     Bus Address: 0000:00:1f.7
- Handle 0x0057, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:5.3
-     Type: x8 PCI Express 3 x16
-     Bus Address: 0000:00:1f.7
- Handle 0x0058, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:5.4
-     Type: x8 PCI Express 3 x16
-     Bus Address: 0000:00:1f.7
- Handle 0x0059, DMI type 9, 17 bytes
- System Slot Information
-     Designation: SlotID:5.5
-     Type: x8 PCI Express 3 x16
-     Bus Address: 0000:00:1f.7
-```
-
-### Linux dmidecode memory
-
-```
- $ dmidecode -t memory
- # dmidecode 2.12
- SMBIOS 2.8 present.
-
- Handle 0x0022, DMI type 16, 23 bytes
- Physical Memory Array
-     Location: System Board Or Motherboard
-     Use: System Memory
-     Error Correction Type: Multi-bit ECC
-     Maximum Capacity: 1536 GB
-     Error Information Handle: Not Provided
-     Number Of Devices: 24
-
- Handle 0x0024, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_A1
-     Bank Locator: NODE 0 CHANNEL 0 DIMM 0
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80EC7380
-     Asset Tag: DIMM_A1_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x0025, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_A2
-     Bank Locator: NODE 0 CHANNEL 0 DIMM 1
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80EC73D1
-     Asset Tag: DIMM_A2_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x0026, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: Unknown
-     Data Width: Unknown
-     Size: No Module Installed
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_A3
-     Bank Locator: NODE 0 CHANNEL 0 DIMM 2
-     Type: Other
-     Type Detail: None
-     Speed: Unknown
-     Manufacturer: NO DIMM
-     Serial Number: NO DIMM
-     Asset Tag: NO DIMM
-     Part Number: NO DIMM
-     Rank: Unknown
-     Configured Clock Speed: Unknown
-
- Handle 0x0027, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_B1
-     Bank Locator: NODE 0 CHANNEL 1 DIMM 0
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80EC7325
-     Asset Tag: DIMM_B1_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x0028, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_B2
-     Bank Locator: NODE 0 CHANNEL 1 DIMM 1
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80EC7334
-     Asset Tag: DIMM_B2_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x0029, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: Unknown
-     Data Width: Unknown
-     Size: No Module Installed
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_B3
-     Bank Locator: NODE 0 CHANNEL 1 DIMM 2
-     Type: Other
-     Type Detail: None
-     Speed: Unknown
-     Manufacturer: NO DIMM
-     Serial Number: NO DIMM
-     Asset Tag: NO DIMM
-     Part Number: NO DIMM
-     Rank: Unknown
-     Configured Clock Speed: Unknown
-
- Handle 0x002A, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_C1
-     Bank Locator: NODE 0 CHANNEL 2 DIMM 0
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80EC7329
-     Asset Tag: DIMM_C1_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x002B, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_C2
-     Bank Locator: NODE 0 CHANNEL 2 DIMM 1
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80EC732D
-     Asset Tag: DIMM_C2_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x002C, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: Unknown
-     Data Width: Unknown
-     Size: No Module Installed
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_C3
-     Bank Locator: NODE 0 CHANNEL 2 DIMM 2
-     Type: Other
-     Type Detail: None
-     Speed: Unknown
-     Manufacturer: NO DIMM
-     Serial Number: NO DIMM
-     Asset Tag: NO DIMM
-     Part Number: NO DIMM
-     Rank: Unknown
-     Configured Clock Speed: Unknown
-
- Handle 0x002D, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_D1
-     Bank Locator: NODE 0 CHANNEL 3 DIMM 0
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80EC73D3
-     Asset Tag: DIMM_D1_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x002E, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_D2
-     Bank Locator: NODE 0 CHANNEL 3 DIMM 1
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80EC7330
-     Asset Tag: DIMM_D2_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x002F, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: Unknown
-     Data Width: Unknown
-     Size: No Module Installed
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_D3
-     Bank Locator: NODE 0 CHANNEL 3 DIMM 2
-     Type: Other
-     Type Detail: None
-     Speed: Unknown
-     Manufacturer: NO DIMM
-     Serial Number: NO DIMM
-     Asset Tag: NO DIMM
-     Part Number: NO DIMM
-     Rank: Unknown
-     Configured Clock Speed: Unknown
-
- Handle 0x0030, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_E1
-     Bank Locator: NODE 1 CHANNEL 0 DIMM 0
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80E54252
-     Asset Tag: DIMM_E1_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x0031, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_E2
-     Bank Locator: NODE 1 CHANNEL 0 DIMM 1
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80E54235
-     Asset Tag: DIMM_E2_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x0032, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: Unknown
-     Data Width: Unknown
-     Size: No Module Installed
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_E3
-     Bank Locator: NODE 1 CHANNEL 0 DIMM 2
-     Type: Other
-     Type Detail: None
-     Speed: Unknown
-     Manufacturer: NO DIMM
-     Serial Number: NO DIMM
-     Asset Tag: NO DIMM
-     Part Number: NO DIMM
-     Rank: Unknown
-     Configured Clock Speed: Unknown
-
- Handle 0x0033, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_F1
-     Bank Locator: NODE 1 CHANNEL 1 DIMM 0
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80E54218
-     Asset Tag: DIMM_F1_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x0034, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_F2
-     Bank Locator: NODE 1 CHANNEL 1 DIMM 1
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80E54236
-     Asset Tag: DIMM_F2_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x0035, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: Unknown
-     Data Width: Unknown
-     Size: No Module Installed
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_F3
-     Bank Locator: NODE 1 CHANNEL 1 DIMM 2
-     Type: Other
-     Type Detail: None
-     Speed: Unknown
-     Manufacturer: NO DIMM
-     Serial Number: NO DIMM
-     Asset Tag: NO DIMM
-     Part Number: NO DIMM
-     Rank: Unknown
-     Configured Clock Speed: Unknown
-
- Handle 0x0036, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_G1
-     Bank Locator: NODE 1 CHANNEL 2 DIMM 0
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80E54247
-     Asset Tag: DIMM_G1_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x0037, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_G2
-     Bank Locator: NODE 1 CHANNEL 2 DIMM 1
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80E5421E
-     Asset Tag: DIMM_G2_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x0038, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: Unknown
-     Data Width: Unknown
-     Size: No Module Installed
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_G3
-     Bank Locator: NODE 1 CHANNEL 2 DIMM 2
-     Type: Other
-     Type Detail: None
-     Speed: Unknown
-     Manufacturer: NO DIMM
-     Serial Number: NO DIMM
-     Asset Tag: NO DIMM
-     Part Number: NO DIMM
-     Rank: Unknown
-     Configured Clock Speed: Unknown
-
- Handle 0x0039, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_H1
-     Bank Locator: NODE 1 CHANNEL 3 DIMM 0
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80E5423C
-     Asset Tag: DIMM_H1_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x003A, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: 72 bits
-     Data Width: 64 bits
-     Size: 32 GB
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_H2
-     Bank Locator: NODE 1 CHANNEL 3 DIMM 1
-     Type: Other
-     Type Detail: None
-     Speed: 2133 MHz
-     Manufacturer: 0xAD00
-     Serial Number: 80E5424D
-     Asset Tag: DIMM_H2_AssetTag
-     Part Number: HMA84GL7MMR4N-TF
-     Rank: 4
-     Configured Clock Speed: 2133 MHz
-
- Handle 0x003B, DMI type 17, 34 bytes
- Memory Device
-     Array Handle: 0x0022
-     Error Information Handle: Not Provided
-     Total Width: Unknown
-     Data Width: Unknown
-     Size: No Module Installed
-     Form Factor: DIMM
-     Set: None
-     Locator: DIMM_H3
-     Bank Locator: NODE 1 CHANNEL 3 DIMM 2
-     Type: Other
-     Type Detail: None
-     Speed: Unknown
-     Manufacturer: NO DIMM
-     Serial Number: NO DIMM
-     Asset Tag: NO DIMM
-     Part Number: NO DIMM
-     Rank: Unknown
-     Configured Clock Speed: Unknown
-```
-
-### Xeon Hsw Server BIOS Configuration
-
-```
- C240 / # scope bios
- C240 /bios # show advanced detail
- Set-up parameters:
-    Intel(R) VT-d ATS Support: Enabled
-    Adjacent Cache Line Prefetcher: Enabled
-    All Onboard LOM Ports: Enabled
-    Altitude: 300 M
-    Bits per second: 115200
-    Power Technology: Performance
-    Channel Interleaving: Auto
-    Intel(R) VT-d Coherency Support: Disabled
-    Console Redirection: COM 0
-    Number of Enabled Cores: All
-    Energy Performance: Performance
-    CPU Performance: Enterprise
-    DCU IP Prefetcher: Enabled
-    DCU Streamer Prefetch: Enabled
-    Demand Scrub: Enabled
-    Direct Cache Access Support: Auto
-    Enhanced Intel Speedstep(R) Tec: Disabled
-    Execute Disable: Enabled
-    Flow Control: None
-    Hardware Prefetcher: Enabled
-    Intel(R) Hyper-Threading Techno: Disabled
-    Intel(R) Turbo Boost Technology: Disabled
-    Intel(R) VT: Enabled
-    Intel(R) VT-d: Enabled
-    Intel(R) Interrupt Remapping: Enabled
-    Legacy USB Support: Enabled
-    Extended APIC: XAPIC
-    LOM Port 1 OptionROM: Enabled
-    LOM Port 2 OptionROM: Enabled
-    MMIO above 4GB: Enabled
-    NUMA: Enabled
-    PCI ROM CLP: Disabled
-    Package C State Limit: C6 Retention
-    Intel(R) Pass Through DMA: Disabled
-    Patrol Scrub: Enabled
-    xHCI Mode: Disabled
-    All PCIe Slots OptionROM: Enabled
-    PCIe Slot:1 OptionROM: Disabled
-    PCIe Slot:2 OptionROM: Disabled
-    PCIe Slot:3 OptionROM: Disabled
-    PCIe Slot:4 OptionROM: Disabled
-    PCIe Slot:5 OptionROM: Disabled
-    PCIe Slot:6 OptionROM: Disabled
-    PCIe Slot:HBA Link Speed: GEN3
-    PCIe Slot:HBA OptionROM: Enabled
-    PCIe Slot:MLOM OptionROM: Enabled
-    PCIe Slot:N1 OptionROM: Enabled
-    PCIe Slot:N2 OptionROM: Enabled
-    Processor Power state C1 Enhanc: Disabled
-    Processor C3 Report: Disabled
-    Processor C6 Report: Disabled
-    P-STATE Coordination: HW ALL
-    Putty KeyPad: ESCN
-    Energy Performance Tuning: BIOS
-    QPI Link Frequency Select: Auto
-    QPI Snoop Mode: Home Snoop
-    Rank Interleaving: Auto
-    Redirection After BIOS POST: Always Enable
-    PCH SATA Mode: AHCI
-    Select Memory RAS: Maximum Performance
-    SR-IOV Support: Enabled
-    Terminal Type: VT100
-    Port 60/64 Emulation: Enabled
-    Workload Configuration: Balanced
-    CDN Support for VIC: Disabled
-    Out-of-Band Management: Disabled
- C240-FCH1950V1H5 /bios/advanced #
-```
-