FIX: Selecting VPP packages
[csit.git] / docs / lab / Testbeds_Xeon_Skx_Arm_Atom.md
index 1875c31..3227ee0 100644 (file)
@@ -1,8 +1,12 @@
 ## FD.io CSIT testbeds - Xeon Skylake, Arm, Atom
-This is a low-level design implemented as an extensions of FD.io CSIT lab to accommodate the new Intel Xeon Skylake, Arm AArch64 and Atom devices. Content has been copied from [FD.io CSIT testbeds wiki page: Xeon_skx, Arm, Atom](https://wiki.fd.io/view/CSIT/Testbeds:_Xeon_Skx,_Arm,_Atom).
+
+This is a low-level design implemented as an extensions of FD.io CSIT lab to
+accommodate the new Intel Xeon Skylake, Arm AArch64 and Atom devices.
 
 ## Testbeds Overview
+
 ### Testbeds Type Breakdown
+
 ```
  #.  CSIT_tb.           Purpose.    SUT.  TG.   #tb.  #SUTs.  #TGs. #skx_node.
  1.  1-node Xeon.       func.       skx.  n/a.  2.    2.      0.    2.
@@ -17,31 +21,57 @@ This is a low-level design implemented as an extensions of FD.io CSIT lab to acc
 ```
 
 ### 1-Node Xeon Testbeds
-One 1-node Xeon testbed for VPP_Device tests is built using one SUT (Type-6 server), with NIC ports connected back-to-back.
+
+One 1-node Xeon testbed for VPP_Device tests is built using one SUT (Type-6
+server), with NIC ports connected back-to-back.
 
 ### 2-Node Xeon Testbeds
-Four 2-node Xeon testbeds (are expected to be built|are built), with each testbed using one SUTs (Type-1 server) and one TG (Type-2 server) connected back-to-back. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections.
+
+Four 2-node Xeon testbeds (are expected to be built|are built), with each
+testbed using one SUTs (Type-1 server) and one TG (Type-2 server) connected
+back-to-back. NIC cards placement into slots and NIC ports connectivity is
+following the testbed specification included in next sections.
 
 ### 3-Node Xeon Testbeds
-Two 3-node Xeon testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-1 server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections.
+
+Two 3-node Xeon testbeds (are expected to be built|are built), with each testbed
+using two SUTs (Type-1 server) and one TG (Type-2 server) connected in full-mesh
+triangle. NIC cards placement into slots and NIC ports connectivity is following
+the testbed specification included in next sections.
 
 ### 1-Node Arm Marvell ThunderX2 Testbed
-One 1-node ThunderX2 testbed for VPP_Device tests is expected to be built using one SUT (Type-9 server), with NIC ports connected back-to-back.
+
+One 1-node ThunderX2 testbed for VPP_Device tests is expected to be built using
+one SUT (Type-9 server), with NIC ports connected back-to-back.
 
 ### 3-Node Arm Huawei TaiShan Testbed
-One 3-node TaiShan testbed is built, with each testbed using two SUTs (Type-3 server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections.
+
+One 3-node TaiShan testbed is built, with each testbed using two SUTs (Type-3
+server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards
+placement into slots and NIC ports connectivity is following the testbed
+specification included in next sections.
 
 ### 3-Node Arm Marvell MACCHIATObin Testbed
-One 3-node MACCHIATObin testbeds is built, with each testbed using two SUTs (Type-4 server) and one TG (Type-2 server) connected in full-mesh triangle. Built-in NIC ports connectivity is following the testbed specification included in next sections.
+
+One 3-node MACCHIATObin testbeds is built, with each testbed using two SUTs
+(Type-4 server) and one TG (Type-2 server) connected in full-mesh triangle.
+Built-in NIC ports connectivity is following the testbed specification included
+in next sections.
 
 ### TCP/IP and L47 Testbeds
+
 One 2-node Ixia PS One and Xeon server testbed, for TCP/IP host stack tests.
 
 ### Atom Testbeds
-One 3-node Atom (Netgate based) testbed is built consisting of three SUTs (Type-5 Netgate device.) NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in the next section.
+One 3-node Atom (Netgate based) testbed is built consisting of three SUTs
+(Type-5 Netgate device.) NIC cards placement into slots and NIC ports
+connectivity is following the testbed specification included in the next
+section.
 
 ## Inventory
+
 ### Appliances
+
 ```
 1. Ixia PerfectStorm One Appliance
     - 1 * PS10GE4NG
@@ -56,6 +86,7 @@ One 3-node Atom (Netgate based) testbed is built consisting of three SUTs (Type-
 ```
 
 ### Arm Servers
+
 ```
 1. Arm Cortex A-72 servers
     - 1 * ThunderX2
@@ -95,6 +126,7 @@ Huawei TaiShan 2280 | CSIT Performance | Up, Manual perf experiments | s17-t33-s
   | | VPP dev debug | Up, Manual VPP Device experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | fdio-mcbin3 | 10.30.51.43 | 10.30.51.49, then connect to /dev/ttyUSB2 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.5
 
 ### Xeon and Atom Servers
+
 ```
 1. Intel Xeon servers:
     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
@@ -112,6 +144,7 @@ Huawei TaiShan 2280 | CSIT Performance | Up, Manual perf experiments | s17-t33-s
 ```
 
 ### Network Interface Cards
+
 ```
 1. 10GE NICs
     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
@@ -126,7 +159,9 @@ Huawei TaiShan 2280 | CSIT Performance | Up, Manual perf experiments | s17-t33-s
 ```
 
 ### Pluggables and Cables
+
 Pluggables:
+
 ```
 1. 10GE SFP+
     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
@@ -140,6 +175,7 @@ Pluggables:
 ```
 
 Standalone cables:
+
 ```
 1. 10GE
     - None
@@ -152,25 +188,36 @@ Standalone cables:
 ```
 
 ### Other Network Cards
+
 Any QATs?
 
 ## Installation Status
-Lab installation status is tracked by LF IT team in [FD.io Server Status](https://docs.google.com/document/d/16TdvGC73wuNQjkP355MTXRckv7yqnaxJkWwX7G7izEo/edit?ts=5b10411b#heading=h.dprb64shku8u).
+
+Lab installation status is tracked by LF IT team in
+[FD.io Server Status](https://docs.google.com/document/d/16TdvGC73wuNQjkP355MTXRckv7yqnaxJkWwX7G7izEo/edit?ts=5b10411b#heading=h.dprb64shku8u).
 
 ## Server/Device Management and Naming
+
 ### Server Management Requirements
+
 Total of 20 SM SYS-7049GP-TRT servers are made available for FD.IO CSIT testbed.
-For management purposes, each server must have following two ports connected to the management network:
+For management purposes, each server must have following two ports connected to
+the management network:
+
 ```
 - 1GE IPMI port
   - IPMI - Intelligent Platform Management Interface.
-  - Required for access to embedded server management with WebUI, CLI, SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
+  - Required for access to embedded server management with WebUI, CLI, SNMPv3,
+    IPMIv2.0, for firmware (BIOS) and OS updates.
 - 1GE/10GE management port
   - hostOS management port for general system management.
 ```
 
 ### Server and Port Naming Convention
-Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds:
+
+Following naming convention is used within this page to specify physical
+connectivity and wiring across defined CSIT testbeds:
+
 ```
 - testbedname: testbedN.
 - hostname:
@@ -190,7 +237,10 @@ Following naming convention is used within this page to specify physical connect
 ```
 
 ### Server Management - Addressing
-Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port, which are connected to two different VLANs.
+
+Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management
+port, which are connected to two different VLANs.
+
 ```
 1. LOM (IPMI) VLAN:
     - Subnet: 10.30.50.0/24
@@ -205,6 +255,7 @@ Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port
     - DNS1: 199.204.44.24
     - DNS2: 199.204.47.54
 ```
+
 To access these hosts, an VPN connection is required.
 
 ### LOM (IPMI) VLAN IP Addresses
@@ -214,9 +265,14 @@ To access these hosts, an VPN connection is required.
 ..
 
 ## Testbeds Specification - Target Build
+
 ### Server/Ports Naming, NIC Placement
+
 #### 1-Node Xeon
-Each server in 1-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
+
+Each server in 1-node Xeon topology has its NIC cards placed, and NIC cards and
+ports indexed per following specification:
+
 ```
 - Server1 [Type-6]:
     - testbedname: testbed11.
@@ -249,7 +305,10 @@ Each server in 1-node Xeon topology has its NIC cards placed, and NIC cards and
 ```
 
 #### 2-Node Xeon
-Each server in 2-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
+
+Each server in 2-node Xeon topology has its NIC cards placed, and NIC cards and
+ports indexed per following specification:
+
 ```
 - Server3 [Type-1]:
     - testbedname: testbed21.
@@ -366,7 +425,10 @@ Each server in 2-node Xeon topology has its NIC cards placed, and NIC cards and
 ```
 
 #### 3-Node Xeon
-Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
+
+Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and
+ports indexed per following specification:
+
 ```
 - Server11 [Type-1]:
     - testbedname: testbed31.
@@ -455,6 +517,7 @@ Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and
 ```
 
 #### 1-Node Arm
+
 ```
 - Server17 [Type-3]:
     - testbedname: testbed13.
@@ -471,7 +534,9 @@ Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and
 ```
 
 #### 3-Node Arm
+
 Note: Server19 (TG) is shared between testbed33 & testbed34
+
 ```
 - Server17 [Type-3]:
     - testbedname: testbed33.
@@ -528,7 +593,10 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
 ```
 
 #### TCP/IP and L47
-Each server (appliance) in 2-node TCP/IP topology has its NIC cards placed, and NIC cards and ports indexed per following specification:
+
+Each server (appliance) in 2-node TCP/IP topology has its NIC cards placed, and
+NIC cards and ports indexed per following specification:
+
 ```
 - Server25 [Type-8]:
     - testbedname: testbed25.
@@ -553,7 +621,9 @@ Each server (appliance) in 2-node TCP/IP topology has its NIC cards placed, and
 ```
 
 #### 3-Node Atom
+
 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
+
 ```
 - Server22 [Type-5]:
     - testbedname: testbed35.
@@ -585,8 +655,12 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
 ```
 
 ### Physical Connectivity within Testbeds
+
 #### 1-Node Xeon
-Two 1-Node testbeds are constructed by connecting 2 Xeon servers using below specification:
+
+Two 1-Node testbeds are constructed by connecting 2 Xeon servers using below
+specification:
+
 ```
 - testbed11:
     - ring1 10GE-ports x710-4p10GE:
@@ -609,7 +683,10 @@ Two 1-Node testbeds are constructed by connecting 2 Xeon servers using below spe
 ```
 
 #### 2-Node Xeon
-Four 2-Node testbeds are constructed by connecting 8 Xeon servers using below specification:
+
+Four 2-Node testbeds are constructed by connecting 8 Xeon servers using below
+specification:
+
 ```
 - testbed21:
     - ring1 10GE-ports x710-4p10GE on SUT:
@@ -678,7 +755,10 @@ Four 2-Node testbeds are constructed by connecting 8 Xeon servers using below sp
 ```
 
 #### 3-Node Xeon
-Two 3-Node testbeds are constructed by connecting 6 Xeon servers using below specification:
+
+Two 3-Node testbeds are constructed by connecting 6 Xeon servers using below
+specification:
+
 ```
 - testbed31:
     - ring1 10GE-ports x710-4p10GE on SUTs:
@@ -724,7 +804,10 @@ Two 3-Node testbeds are constructed by connecting 6 Xeon servers using below spe
 
 
 #### 1-Node Arm
-One 1-Node testbed is constructed by connecting 1 Arm server using below specification:
+
+One 1-Node testbed is constructed by connecting 1 Arm server using below
+specification:
+
 ```
 - testbed13:
     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
@@ -735,9 +818,11 @@ One 1-Node testbed is constructed by connecting 1 Arm server using below specifi
         - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
 ```
 
-
 #### 3-Node Arm
-One 3-Node testbed is constructed by connecting 2 TaiShan servers and one Xeon server using below specification:
+
+One 3-Node testbed is constructed by connecting 2 TaiShan servers and one Xeon
+server using below specification:
+
 ```
 - testbed33:
     - ring1 10GE-ports 82599-2p10GE on SUTs:
@@ -749,7 +834,10 @@ One 3-Node testbed is constructed by connecting 2 TaiShan servers and one Xeon s
         - t33-sut1-c4/p1 - t33-sut2-c4/p2.
         - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
 ```
-One 3-Node testbed is constructed by connecting 2 MACCHIATObin servers and one Xeon server using below specification:
+
+One 3-Node testbed is constructed by connecting 2 MACCHIATObin servers and one
+Xeon server using below specification:
+
 ```
 - testbed34:
     - ring1 10GE-ports Marvell on SUTs:
@@ -759,7 +847,10 @@ One 3-Node testbed is constructed by connecting 2 MACCHIATObin servers and one X
 ```
 
 #### TCP/IP and L47
-One 2-Node TCP/IP testbed is constructed by connecting Ixia PSOne and 1 Xeon server using below specification:
+
+One 2-Node TCP/IP testbed is constructed by connecting Ixia PSOne and 1 Xeon
+server using below specification:
+
 ```
 - testbed25:
     - link1 10GE-port x710-4p10GE on SUT:
@@ -773,13 +864,19 @@ One 2-Node TCP/IP testbed is constructed by connecting Ixia PSOne and 1 Xeon ser
 ```
 
 #### 3-Node Atom
+
 ..
 
 ## Server Specification
+
 ### Hardware Configuration
-The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware server configurations:
+
+The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
+server configurations:
+
 ```
-1. Type-1: Purpose - (Intel Xeon Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
+1. Type-1: Purpose - (Intel Xeon Processor) SUT for SW Data Plane Workload i.e.
+   VPP, testpmd.
     - Quantity: TBD based on testbed allocation.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -819,7 +916,8 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-3. Type-3: Purpose - (Arm hip07-d05 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
+3. Type-3: Purpose - (Arm hip07-d05 Processor) SUT for SW Data Plane Workload
+   i.e. VPP, testpmd.
     - Quantity: 2
     - Physical connectivity:
         - IPMI(?) and host management ports.
@@ -832,7 +930,8 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
     - NICs configuration:
         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
         - PCIe Slot6 11:00.xx: 82599-2p10GE Intel.
-4. Type-4: Purpose - (Arm Armada 8040 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
+4. Type-4: Purpose - (Arm Armada 8040 Processor) SUT for SW Data Plane Workload
+   i.e. VPP, testpmd.
     - Quantity: 3
     - Physical connectivity:
         - Host management ports.
@@ -844,7 +943,8 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
         - Disks: 1* 128GB(?) SATA SDD
     - NICs configuration:
         - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
-5. Type-5: Purpose - (Intel Atom Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
+5. Type-5: Purpose - (Intel Atom Processor) SUT for SW Data Plane Workload i.e.
+   VPP, testpmd.
     - Quantity: TBD based on testbed allocation.
     - Physical connectivity:
         - Management: serial Port (usb) for console
@@ -877,7 +977,8 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-7. Type-7: Purpose - Ixia PerfectStorm One Appliance TG for TCP/IP performance tests.
+7. Type-7: Purpose - Ixia PerfectStorm One Appliance TG for TCP/IP performance
+   tests.
     - Quantity: 1.
     - Physical connectivity:
         - Host management interface: 10/100/1000-BaseT.
@@ -916,7 +1017,8 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-9. Type-9: Purpose - (Marvell ThunderX2 Processor) SUT for VPP_Device functional tests.
+9. Type-9: Purpose - (Marvell ThunderX2 Processor) SUT for VPP_Device functional
+   tests.
     - Quantity: 1
     - Physical connectivity:
         - IPMI and host management ports.
@@ -933,7 +1035,8 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
             - PCIe Slot3 08:00.xx: XL710-QDA2.
         - Numa1:
             - PCIe Slot6 85:00.xx: XL710-QDA2.
-10. Type-10: Purpose - (Intel Atom C3000 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd.
+10. Type-10: Purpose - (Intel Atom C3000 Processor) SUT for SW Data Plane
+    Workload i.e. VPP, testpmd.
     - Quantity: 4
     - Physical connectivity:
         - IPMI and host management ports.
@@ -950,7 +1053,9 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ### Xeon Skx Server BIOS Configuration
+
 #### Boot Feature
+
 ```
   |  Quiet Boot                                [Enabled]               |Boot option                  |
   |                                                                    |                             |
@@ -970,6 +1075,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 #### CPU Configuration
+
 ```
   |  Processor Configuration                                           |Enables Hyper Threading      |
   |  --------------------------------------------------                |(Software Method to          |
@@ -1004,6 +1110,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ##### Advanced Power Management Configuration
+
 ```
   |  Advanced Power Management Configuration                           |Switch CPU Power Management  |
   |  --------------------------------------------------                |profile                      |
@@ -1018,6 +1125,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ###### CPU P State Control
+
 ```
   |  CPU P State Control                                               |Enable/Disable EIST          |
   |                                                                    |(P-States)                   |
@@ -1026,6 +1134,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ###### Hardware PM State Control
+
 ```
   |  Hardware PM State Control                                         |Disable: Hardware chooses a  |
   |                                                                    |P-state based on OS Request  |
@@ -1039,6 +1148,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ###### CPU C State Control
+
 ```
   |  CPU C State Control                                               |Autonomous Core C-State      |
   |                                                                    |Control                      |
@@ -1048,6 +1158,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ###### Package C State Control
+
 ```
   |  Package C State Control                                           |Package C State limit        |
   |                                                                    |                             |
@@ -1055,6 +1166,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ###### CPU T State Control
+
 ```
   |  CPU T State Control                                               |Enable/Disable Software      |
   |                                                                    |Controlled T-States          |
@@ -1062,6 +1174,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ##### Chipset Configuration
+
 ```
   |  WARNING: Setting wrong values in below sections may cause         |North Bridge Parameters      |
   |           system to malfunction.                                   |                             |
@@ -1070,6 +1183,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ###### North Bridge
+
 ```
   |> UPI Configuration                                                 |Displays and provides        |
   |> Memory Configuration                                              |option to change the UPI     |
@@ -1077,6 +1191,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ###### UPI Configuration
+
 ```
   |  UPI Configuration                                                 |Choose Topology Precedence   |
   |  --------------------------------------------------                |to degrade features if       |
@@ -1101,6 +1216,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ###### Memory Configuration
+
 ```
   |                                                                    |POR - Enforces Plan Of       |
   |  --------------------------------------------------                |Record restrictions for      |
@@ -1121,6 +1237,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ###### IIO Configuration
+
 ```
   |  IIO Configuration                                                 |Expose IIO DFX devices and   |
   |  --------------------------------------------------                |other CPU devices like PMON  |
@@ -1138,6 +1255,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ###### CPU1 Configuration
+
 ```
   |  IOU0 (IIO PCIe Br1)                       [Auto]                  |Selects PCIe port            |
   |  IOU1 (IIO PCIe Br2)                       [Auto]                  |Bifurcation for selected     |
@@ -1148,6 +1266,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ###### CPU2 Configuration
+
 ```
   |  IOU0 (IIO PCIe Br1)                       [Auto]                  |Selects PCIe port            |
   |  IOU1 (IIO PCIe Br2)                       [Auto]                  |Bifurcation for selected     |
@@ -1158,6 +1277,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ##### South Bridge
+
 ```
   |                                                                    |Enables Legacy USB support.  |
   |  USB Module Version                        17                      |AUTO option disables legacy  |
@@ -1177,6 +1297,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 #### PCIe/PCI/PnP Configuration
+
 ```
   |  PCI Bus Driver Version                    A5.01.12                |Enables or Disables 64bit    |
   |                                                                    |capable Devices to be        |
@@ -1204,6 +1325,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 #### ACPI Settings
+
 ```
   |  ACPI Settings                                                     |Enable or Disable Non        |
   |                                                                    |uniform Memory Access        |
@@ -1214,6 +1336,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 #### DMIDECODE
+
 ```
   # dmidecode 3.1
   Getting SMBIOS data from sysfs.
@@ -1414,6 +1537,7 @@ The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware
 ```
 
 ### Xeon Skx Server Firmware Inventory
+
 ```
 Host.           IPMI IP.      BIOS. CPLD.     Aptio SU.   CPU Microcode.  PCI Bus.   ME Operation FW.    X710 Firmware.            XXV710 Firmware.          i40e.