Code Review
/
csit.git
/ blobdiff
commit
grep
author
committer
pickaxe
?
search:
re
summary
|
shortlog
|
log
|
commit
|
commitdiff
|
review
|
tree
raw
|
inline
| side by side
feat(infra): Onboard Mellanox I.
[csit.git]
/
docs
/
lab
/
testbed_specifications.md
diff --git
a/docs/lab/testbed_specifications.md
b/docs/lab/testbed_specifications.md
index
579ccf4
..
2c1cd38
100644
(file)
--- a/
docs/lab/testbed_specifications.md
+++ b/
docs/lab/testbed_specifications.md
@@
-668,7
+668,7
@@
FD.io CSIT lab contains following server types:
- PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
- PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx: e
mpty
.
+ - PCIe Slot6 86:00.xx: e
810-2p100GE Intel
.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
- PCIe Slot8 af:00.xx: empty.
- PCIe Slot10 d8:00.xx: empty.
13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
@@
-688,13
+688,13
@@
FD.io CSIT lab contains following server types:
- PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
- PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
- Numa1: (x16, x16, x16 PCIe3.0 lanes)
- - PCIe Slot6 86:00.xx:
empty
.
- - PCIe Slot8 af:00.xx:
empty
.
+ - PCIe Slot6 86:00.xx:
ConnectX5-2p100GE Mellanox
.
+ - PCIe Slot8 af:00.xx:
ConnectX5-2p100GE Mellanox
.
- PCIe Slot10 d8:00.xx: empty.
14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
- Quantity: 3.
- Physical connectivity:
- PCIe Slot10 d8:00.xx: empty.
14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
- Quantity: 3.
- Physical connectivity:
- -
CIMC
and host management ports.
+ -
IPMI
and host management ports.
- no NIC ports, standalone setup.
- Main HW configuration:
- Chassis: SuperMicro 1029P-WTRT.
- no NIC ports, standalone setup.
- Main HW configuration:
- Chassis: SuperMicro 1029P-WTRT.
@@
-1232,8
+1232,10
@@
Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
+ - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+ - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
- s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- SUT [Server-Type-C2]:
- s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- SUT [Server-Type-C2]:
@@
-1264,8
+1266,10
@@
Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
- - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
+ - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+ - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+ - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
- s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- SUT [Server-Type-C2]:
- s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
- SUT [Server-Type-C2]:
@@
-1296,8
+1300,8
@@
Note: ServerB28 (TG) is shared between testbed26 & testbed35
- s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
- s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
- s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
- - s38-t29-tg1-c6/p1 - 100GE-port1
e810
-2p100GE.
- - s38-t29-tg1-c6/p2 - 100GE-port2
e810
-2p100GE.
+ - s38-t29-tg1-c6/p1 - 100GE-port1
ConnectX5
-2p100GE.
+ - s38-t29-tg1-c6/p2 - 100GE-port2
ConnectX5
-2p100GE.
- s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
```
- s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
- s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
```
@@
-1964,9
+1968,12
@@
Note: Server64 (TG) is shared between testbed34 & testbed36
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
- s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
- s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
- - ring5 100GE-ports e810-2p100GE on SUT:
+ - ring5 100GE-ports e810-2p100GE on SUT
100GE-ports ConnectX5-2p100GE on TG
:
- s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
- s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
- s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
- s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
+ - ring6 100GE-ports e810-2p100GE on TG:
+ - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
+ - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
- testbed28:
- ring1 10GE-ports x710-4p10GE on SUT:
- s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
- testbed28:
- ring1 10GE-ports x710-4p10GE on SUT:
- s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
@@
-1980,9
+1987,12
@@
Note: Server64 (TG) is shared between testbed34 & testbed36
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
- s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
- s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
- - ring5 100GE-ports e810-2p100GE on SUT:
+ - ring5 100GE-ports e810-2p100GE on SUT
100GE-ports ConnectX5-2p100GE on TG
:
- s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
- s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
- s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
- s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
+ - ring6 100GE-ports e810-2p100GE on TG:
+ - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
+ - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
- testbed29:
- ring1 10GE-ports x710-4p10GE on SUT:
- s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
- testbed29:
- ring1 10GE-ports x710-4p10GE on SUT:
- s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
@@
-1996,7
+2006,7
@@
Note: Server64 (TG) is shared between testbed34 & testbed36
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
- s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
- ring4 100GE-ports ConnectX5-2p100GE on SUT:
- s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
- s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
- - ring
6 100GE-ports e810-2p100GE on SUT
:
+ - ring
5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG
:
- s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
- s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
```
- s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
- s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
```