feat(docs): Add SPR inventory types
[csit.git] / docs / lab / testbed_specifications.md
index fad1bdc..1c2d912 100644 (file)
@@ -6,24 +6,20 @@
    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
-   1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
-   1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
    1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
    1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
    1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
-   1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
    1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
    1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
    1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
+   1. [2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)](#2-node-full-sapphirerapids-xeon-intel-2nf-spr)
+   1. [2-Node-SapphireRapids Xeon Intel (2n-spr)](#2-Node-SapphireRapids-Xeon-Intel-2n-spr)
 1. [Server Management](#server-management)
-   1. [Requirements](#requirements)
    1. [Addressing](#addressing)
-   1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
-   1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
 1. [Server Specifications](#server-specifications)
    1. [Server Types](#server-types)
    1. [Naming Convention](#naming-convention)
       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
       1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
       1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
-      1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
-      1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
       1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
       1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
       1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
       1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
-      1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
       1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
       1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
       1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
       1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
+      1. [2-Node-SapphireRapids Servers (2n-spr) PROD](#2-Node-sapphirerapids-servers-2n-spr-prod)
    1. [Per Testbed Wiring](#per-testbed-wiring)
       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
       1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
       1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
-      1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
-      1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
       1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
       1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
       1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
-      1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
       1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
       1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
       1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
       1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
       1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
-1. [Inventory](#inventory)
-   1. [Appliances](#appliances)
-   1. [Arm Servers](#arm-servers)
-   1. [Xeon and Atom Servers](#xeon-and-atom-servers)
-   1. [Network Interface Cards](#network-interface-cards)
-   1. [Pluggables and Cables](#pluggables-and-cables)
-   1. [Other Parts](#other-parts)
+      1. [2-Node-SapphireRapids Wiring (2n-spr) PROD](#2-Node-sapphirerapids-wiring-2n-spr-prod)
 
 ## Purpose
 
@@ -80,27 +65,22 @@ hosted by LFN FD.io CSIT project.
 ### Summary List
 
 ```
- #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx #snr
- 1. 1-Node-Haswell     nomad  hsw   na    4    4    0    4    0    0    0    0    0    0    0    0    0    0    0
- 2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0    0    0    0
- 3. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0    0    0    0
- 4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0    1    0    0    0
- 5. 1-Node-AmpereAltra nomad  alt   na    2    2    0    0    0    0    0    0    0    0    2    0    0    0    0
- 6. 2-Node-Skylake     perf   skx   skx   3    3    3    0    6    0    0    0    0    0    0    0    0    0    0
- 7. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0    0    0    0
- 8. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0    0    0    0
- 9. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0    6    0    0    0
-10. 2-Node-ThunderX2   perf   tx2   skx   1    1    .5   0    .5   0    0    0    1    0    0    0    0    0    0
-11. 2-Node-Icelake     perf   icx   icx   4    4    4    0    0    0    0    0    0    0    0    0    0    8    0
-12. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0    0    0    0
-13. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0    0    0    0
-14. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0    0    0    0
-15. 3-Node-Altra       perf   alt   icx   1    2    1    0    0    0    0    0    0    0    2    0    0    1    0
-16. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0    0    0    0
-17. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    0    2    0    0
-18. 3-Node-Icelake     perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    0    0    6    0
-19. 3-Node-SnowRidge   perf   snr   icx   1    2    .5   0    0    0    0    0    0    0    0    0    0    .5   2
-                                 Totals: 34   44  21.5   4   17    1    2    3    3    2    4    7    2  15.5   2
+ #. Type                 Purpose  SUT   TG    #TB  #SUT #TG  #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr
+ 1. 1-Node-Skylake         nomad  skx   na    5    5    0    5    0    0    0    0    0    0    0    0    0    0
+ 2. 1-Node-Cascadelake     nomad  clx   na    1    1    0    0    0    0    0    0    0    1    0    0    0    0
+ 3. 1-Node-AmpereAltra     nomad  alt   na    2    2    0    0    0    0    0    0    2    0    0    0    0    0
+ 4. 2-Node-IxiaPS1L47      tcp    skx   ps1   1    1    1    1    1    0    0    0    0    0    0    0    0    0
+ 5. 2-Node-Cascadelake     perf   clx   clx   3    3    3    0    0    0    0    0    0    6    0    0    0    0
+ 6. 2-Node-ThunderX2       perf   tx2   skx   1    1    .5   .5   0    0    1    0    0    0    0    0    0    0
+ 7. 2-Node-Icelake         perf   icx   icx   4    4    4    0    0    0    0    0    0    0    0    8    0    0
+ 8. 3-Node-Rangeley        perf   rng   skx   1    3    1    0    0    2    0    0    0    0    0    0    0    0
+ 9. 3-Node-Taishan         perf   tsh   skx   1    2    .5   .5   0    0    0    2    0    0    0    0    0    0
+10. 3-Node-Altra           perf   alt   icx   1    2    1    0    0    0    0    0    2    0    0    1    0    0
+11. 2-Node-Zen2            perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    2    0    0    0
+12. 3-Node-Icelake         perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    6    0    0
+13. 3-Node-SnowRidge       perf   snr   icx   1    2    .5   0    0    0    0    0    0    0    0    .5   2    0
+13. 2-Node-SapphireRapids  perf   spr   spr   4    4    4    0    0    0    0    0    0    0    0    0    0    8
+                                     Totals: 28   35  18.5   7    1    2    1    2    4    7    2   15.5  2    8
 ```
 
 ### 1-Node-Skylake Xeon Intel (1n-skx)
@@ -122,20 +102,6 @@ NIC ports connected back-to-back ([Server Types](#server-types)).
 
 Used for FD.io VPP_Device functional driver tests.
 
-### 2-Node-Skylake Xeon Intel (2n-skx)
-
-Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
-(Server-Type-B2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-Denverton Atom Intel (2n-dnv)
-
-Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
-TG (Server-Type-B2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
 
 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
@@ -171,19 +137,6 @@ one TG (Server-Type-F2) connected in a 2-node circular topology
 ([Server Types](#server-types)).
 Used for FD.io performance tests.
 
-### 3-Node-Haswell Xeon Intel (3n-hsw)
-
-Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
-TG (Server-Type-A2) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-Skylake Xeon Intel (3n-skx)
-
-Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
-TG (Server-Type-B2) connected in a 3-node circular topology.
-Used for FD.io performance tests.
-
 ### 3-Node-Rangeley Atom Testbeds
 
 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
@@ -219,22 +172,23 @@ TG (Server-Type-F4) connected in a 3-node circular topology
 ([Server Types](#server-types)).
 Used for FD.io performance tests.
 
+### 2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)
 
-## Server Management
+One 2-Node-Full-SapphireRapids testbed includes one SUT (Server-Type-H1) and
+one TG (Server-Type-H2) connected in a 2-node physical topology
+with NUMA (socket) daisy chaining. For more detail see
+[Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
+Used for FD.io performance tests in a full system SUT setup with all PCIe
+Gen5 x16 lane slots populated with 2p200GbE NICs.
 
-### Requirements
+### 2-Node-SapphireRapids Xeon Intel (2n-spr)
 
-For management purposes, each server must have following two ports
-connected to the management network:
+Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and
+one TG (Server-Type-H6) connected in a 2-node circular topology. For more
+detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
+Used for FD.io performance tests.
 
-```
-- 1GE IPMI port
-  - IPMI - Intelligent Platform Management Interface.
-  - Required for access to embedded server management with WebUI, CLI,
-    SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
-- 1GE/10GE/40GE management port
-  - hostOS management port for general system management.
-```
+## Server Management
 
 ### Addressing
 
@@ -258,271 +212,16 @@ Management port, which are connected to two different VLANs.
 
 To access these hosts, VPN connection is required.
 
-### LOM (IPMI) VLAN IP Addresses
-
-Name         | Comment
------------- | -------
-10.30.50.0   | network
-10.30.51.1   | Router
-10.30.50.2   | LF Reserved
-10.30.50.3   | LF Reserved
-10.30.50.4   | LF Reserved
-10.30.50.5   | LF Reserved
-10.30.50.6   | LF Reserved
-10.30.50.7   | LF Reserved
-10.30.50.8   | LF Reserved
-10.30.50.9   | LF Reserved
-10.30.50.10  | LF Reserved
-10.30.50.11  | LF Reserved
-10.30.50.12  | LF Reserved
-10.30.50.13  | LF Reserved
-10.30.50.14  | LF Reserved
-10.30.50.15  | LF Reserved
-10.30.50.16  | s16-nomad
-10.30.50.17  | s17-nomad
-10.30.50.18  | s18-nomad
-10.30.50.19  | s19-nomad
-10.30.50.20  | s20-nomad
-10.30.50.21  | s21-nomad
-10.30.50.22  | s22-nomad
-10.30.50.23  | s23-nomad
-10.30.50.24  | s24-nomad
-10.30.50.25  | s25-nomad
-10.30.50.26  | s26-nomad
-10.30.50.36  | s17-t33-sut1
-10.30.50.37  | s18-t33-sut2
-10.30.50.38  | fdio-marvell-dev
-10.30.50.39  | s53-nomad
-10.30.50.40  | s54-nomad
-10.30.50.41  | s3-t21-sut1
-10.30.50.42  | s4-t21-tg1
-10.30.50.43  | s11-t31-sut1
-10.30.50.44  | s12-t31-sut2
-10.30.50.45  | s13-t31-tg1
-10.30.50.46  | s19-t33t211-tg1
-10.30.50.47  | s1-t11-sut1
-10.30.50.48  | s2-t12-sut1
-10.30.50.49  | s5-t22-sut1
-10.30.50.50  | s6-t22-tg1
-10.30.50.51  | s7-t23-sut1
-10.30.50.52  | s8-t23-tg1
-10.30.50.53  | s9-t24-sut1
-10.30.50.54  | s10-t24-tg1
-10.30.50.55  | s14-t32-sut1
-10.30.50.56  | s15-t32-sut2
-10.30.50.57  | s16-t32-tg1
-10.30.50.58  | s25-t25-sut1
-10.30.50.59  | s26-t25-tg1
-10.30.50.65  | s52-nomad
-10.30.50.66  | s51-nomad
-10.30.50.67  | s49-nomad
-10.30.50.68  | s50-nomad
-10.30.50.69  | s27-t211-sut1
-10.30.50.70  | s55-t13-sut1
-10.30.50.71  | s56-t14-sut1
-10.30.50.72  | s62-t34-sut1
-10.30.50.73  | s63-t34-sut2
-10.30.50.74  | s64-t34-tg1
-10.30.50.75  | s65-t37-sut1
-10.30.50.76  | s66-t37-sut2
-10.30.50.77  | s67-t37-tg1
-10.30.50.78  | s78-t38-sut1
-10.30.50.79  | s79-t38-sut2
-10.30.50.80  | s80-t38-tg1
-10.30.50.81  | s71-t212-sut1
-10.30.50.82  | s72-t212-tg1
-10.30.50.83  | s83-t213-sut1
-10.30.50.84  | s84-t213-tg1
-10.30.50.85  | s85-t214-sut1
-10.30.50.86  | s86-t214-tg1
-10.30.50.87  | s87-t215-sut1
-10.30.50.88  | s88-t215-tg1
-10.30.50.89  | s89-t39t310-tg1
-10.30.50.90  | s90-t311t312-tg1
-10.30.50.91  | s58-nomad
-10.30.50.92  | s59-nomad
-10.30.50.93  | s93-t39-sut1
-10.30.50.94  | s94-t39-sut2
-10.30.50.255 | Broadcast
-10.30.55.0   | network
-10.30.55.1   | Router
-10.30.55.10  | s28-t26t35-tg1
-10.30.55.11  | s29-t26-sut1
-10.30.55.12  | s30-t35-sut1
-10.30.55.13  | s31-t35-sut2
-10.30.55.18  | s33-t27-sut1
-10.30.55.19  | s34-t27-tg1
-10.30.55.20  | s35-t28-sut1
-10.30.55.21  | s36-t28-tg1
-10.30.55.22  | s37-t29-sut1
-10.30.55.23  | s38-t29-tg1
-10.30.55.24  | s60-t210-sut1
-10.30.55.25  | s61-t210-tg1
-10.30.55.255 | Broadcast
-
-### Management VLAN IP Addresses
-
-Name         | Comment
--------------| -------
-10.30.51.0   | network
-10.30.51.1   | Router
-10.30.51.2   | LF Reserved
-10.30.51.3   | LF Reserved
-10.30.51.4   | LF Reserved
-10.30.51.5   | LF Reserved
-10.30.51.6   | LF Reserved
-10.30.51.7   | LF Reserved
-10.30.51.8   | LF Reserved
-10.30.51.15  | LF Reserved
-10.30.51.16  | s16-nomad
-10.30.51.17  | s17-nomad
-10.30.51.18  | s18-nomad
-10.30.51.19  | s19-nomad
-10.30.51.20  | s20-nomad
-10.30.51.21  | s21-nomad
-10.30.51.22  | s22-nomad
-10.30.51.23  | s23-nomad
-10.30.51.24  | s24-nomad
-10.30.51.25  | s25-nomad
-10.30.51.26  | s26-nomad
-10.30.51.36  | s17-t33-sut1
-10.30.51.37  | s18-t33-sut2
-10.30.51.38  | fdio-marvell-dev
-10.30.51.39  | s53-nomad
-10.30.51.40  | s54-nomad
-10.30.51.44  | s3-t21-sut1
-10.30.51.45  | s4-t21-tg1
-10.30.51.46  | s11-t31-sut1
-10.30.51.47  | s12-t31-sut2
-10.30.51.48  | s13-t31-tg1
-10.30.51.49  | s19-t33t211-tg1
-10.30.51.50  | s1-t11-sut1
-10.30.51.51  | s2-t12-sut1
-10.30.51.52  | s5-t22-sut1
-10.30.51.53  | s6-t22-tg1
-10.30.51.54  | s7-t23-sut1
-10.30.51.55  | s8-t23-tg1
-10.30.51.56  | s9-t24-sut1
-10.30.51.57  | s10-t24-tg1
-10.30.51.58  | s14-t32-sut1
-10.30.51.59  | s15-t32-sut2
-10.30.51.60  | s16-t32-tg1
-10.30.51.61  | s25-t25-sut1
-10.30.51.62  | s26-t25-tg1
-10.30.51.65  | s52-nomad
-10.30.51.66  | s51-nomad
-10.30.51.67  | s49-nomad
-10.30.51.68  | s50-nomad
-10.30.51.69  | s27-t211-sut1
-10.30.51.70  | s55-t13-sut1
-10.30.51.71  | s56-t14-sut1
-10.30.51.72  | s62-t34-sut1
-10.30.51.73  | s63-t34-sut2
-10.30.51.74  | s64-t34-tg1
-10.30.51.75  | s65-t37-sut1
-10.30.51.76  | s66-t37-sut2
-10.30.51.77  | s67-t37-tg1
-10.30.51.78  | s78-t38-sut1
-10.30.51.79  | s79-t38-sut2
-10.30.51.80  | s80-t38-tg1
-10.30.51.81  | s71-t212-sut1
-10.30.51.82  | s72-t212-tg1
-10.30.51.83  | s83-t213-sut1
-10.30.51.84  | s84-t213-tg1
-10.30.51.85  | s85-t214-sut1
-10.30.51.86  | s86-t214-tg1
-10.30.51.87  | s87-t215-sut1
-10.30.51.88  | s88-t215-tg1
-10.30.51.89  | s89-t39t310-tg1
-10.30.51.90  | s90-t311t312-tg1
-10.30.51.91  | s58-nomad
-10.30.51.92  | s59-nomad
-10.30.51.93  | s93-t39-sut1
-10.30.51.94  | s94-t39-sut2
-10.30.51.255 | Broadcast
-10.32.8.0    | network
-10.32.8.1    | Router
-10.32.8.10   | s28-t26t35-tg1
-10.32.8.11   | s29-t26-sut1
-10.32.8.12   | s30-t35-sut1
-10.32.8.13   | s31-t35-sut2
-10.32.8.18   | s33-t27-sut1
-10.32.8.19   | s34-t27-tg1
-10.32.8.20   | s35-t28-sut1
-10.32.8.21   | s36-t28-tg1
-10.32.8.22   | s37-t29-sut1
-10.32.8.23   | s38-t29-tg1
-10.32.8.24   | s60-t210-sut1
-10.32.8.25   | s61-t210-tg1
-10.32.8.255  | Broadcast
-
 ## Server Specifications
 
 ### Server Types
 
 FD.io CSIT lab contains following server types:
 ```
-1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
-    - Quantity: 6 servers.
-    - Physical connectivity:
-        - CIMC and host management ports.
-        - NIC ports connected in 3-node topologies.
-    - Main HW configuration:
-        - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
-        - Processors: 2* E5-2699v3 2.3 GHz.
-        - RAM Memory: 16* 32GB DDR4-2133MHz.
-        - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
-    - NICs configuration:
-        - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
-            - PCIe Slot1: empty.
-            - PCIe Slot2: empty.
-            - PCIe Slot3: empty.
-        - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
-            - PCIe Slot4: empty.
-            - PCIe Slot5: empty.
-            - PCIe Slot6: empty
-        - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
-2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
-    - Quantity: 3 servers.
-    - Physical connectivity:
-        - CIMC and host management ports.
-        - NIC ports connected in 3-node topologies.
-    - Main HW configuration:
-        - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
-        - Processors: 2* E5-2699v3 2.3 GHz.
-        - RAM Memory: 16* 32GB DDR4-2133MHz.
-        - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
-    - NICs configuration:
-        - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
-            - PCIe Slot1: empty.
-            - PCIe Slot2: empty.
-            - PCIe Slot3: empty.
-        - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
-            - PCIe Slot4: empty.
-            - PCIe Slot5: empty.
-            - PCIe Slot6: empty
-        - MLOM slot: empty.
-3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
-    - Quantity: 3 servers.
-    - Physical connectivity:
-        - CIMC and host management ports.
-        - no NIC ports, standalone setup.
-    - Main HW configuration:
-        - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
-        - Processors: 2* E5-2699v3 2.3 GHz.
-        - RAM Memory: 16* 32GB DDR4-2133MHz.
-        - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
-    - NICs configuration:
-        - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
-            - no cards.
-        - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
-            - no cards.
-        - MLOM slot: empty.
-4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
+1. Server-Type-B2: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
     - Quantity: ---
     - Physical connectivity:
         - IPMI and host management ports.
-        - NIC ports connected into 2-node and 3-node topologies.
     - Main HW configuration:
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
@@ -531,47 +230,14 @@ FD.io CSIT lab contains following server types:
         - Disks: 2* 1.6TB 6G SATA SSD.
     - NICs configuration:
         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
-            - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
+            - PCIe Slot2 18:00.xx: empty.
+            - PCIe Slot4 3b:00.xx: empty.
             - PCIe Slot9 5e:00.xx: empty.
         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
-    - Quantity: ---
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node and 3-node topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.5 GHz.
-        - RAM Memory: 16* 16GB DDR4-2666MHz.
-        - Disks: 2* 1.6TB 6G SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
-            - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
-            - PCIe Slot9 5e:00.xx: empty.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
-    - Quantity: TBD based on testbed allocation.
-    - Physical connectivity:
-        - Management: serial Port (usb) for console
-        - NIC ports connected into 2-node.
-    - Main HW configuration:
-        - Chassis: Netgate XG-2758-1u
-        - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
-        - RAM Memory: 16GB ECC
-        - Disks: 150 GB
-    - NICs configuration:
-        - 2x 10Gb Intel 82599ES
-        - 4x 1GB Intel I354
-7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
+2. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
     - Quantity: 2.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -591,7 +257,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
+3. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
     - Quantity: 1.
     - Physical connectivity:
         - Host management interface: 10/100/1000-BaseT.
@@ -610,7 +276,7 @@ FD.io CSIT lab contains following server types:
         - Port-2: 10GE SFP+.
         - Port-3: 10GE SFP+.
         - Port-4: 10GE SFP+.
-9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
+4. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
     - Quantity: 1.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -630,21 +296,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
-    - Quantity: 4
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-E300-9A
-        - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
-        - RAM Memory: 32GB ECC
-        - Disks: 480 GB
-    - NICs configuration:
-        - 2x 10Gb Intel x553 fiber ports
-        - 2x 10Gb Intel x553 copper ports
-        - 4x 1GB Intel I350 ports
-11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
+5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
     - Quantity: 1.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -664,7 +316,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
+6. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
     - Quantity: 3
     - Physical connectivity:
         - IPMI and host management ports.
@@ -684,7 +336,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
+7. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
     - Quantity: 3.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -704,7 +356,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
             - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
             - PCIe Slot10 d8:00.xx: empty.
-14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
+8. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
     - Quantity: 3.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -720,7 +372,7 @@ FD.io CSIT lab contains following server types:
             - no cards.
         - Numa1:
             - no cards.
-15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
+9. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
     - Quantity: 1.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -735,7 +387,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
+10. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
     - Quantity: 1.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -750,7 +402,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
-17.  Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
+11.  Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
     - Quantity: 2
     - Physical connectivity:
         - IPMI and host management ports.
@@ -768,7 +420,7 @@ FD.io CSIT lab contains following server types:
         - Numa1:
             - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
             - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
-18.  Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
+12.  Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
     - Quantity: 2
     - Physical connectivity:
         - IPMI(?) and host management ports.
@@ -781,7 +433,7 @@ FD.io CSIT lab contains following server types:
     - NICs configuration:
         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
-19.  Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
+13.  Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
     - Quantity: 1
     - Physical connectivity:
         - IPMI and host management ports.
@@ -797,7 +449,7 @@ FD.io CSIT lab contains following server types:
             - no cards
         - Numa1:
             - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
-20.  Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
+14.  Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
     - Quantity: 2
     - Physical connectivity:
         - IPMI and host management ports.
@@ -814,7 +466,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
         - Numa1:
             - no cards.
-21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
+15. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
     - Quantity: 2.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -825,7 +477,7 @@ FD.io CSIT lab contains following server types:
         - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
         - RAM Memory: 12* 16GB DDR4-3200MT/s
         - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
-22.  Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
+16.  Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
     - Quantity: 1
     - Physical connectivity:
         - IPMI and host management ports.
@@ -845,7 +497,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
+17. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
     - Quantity: 8.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -857,15 +509,15 @@ FD.io CSIT lab contains following server types:
         - RAM Memory: 16* 16GB DDR4-3200.
         - Disks: 2* 960GB SATA SSD.
     - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+        - Numa0: (x16, x16, x16 PCIe4.0 lanes)
             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+        - Numa1: (x16, x16, x16 PCIe4.0 lanes)
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
+18. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
     - Quantity: 3.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -877,15 +529,15 @@ FD.io CSIT lab contains following server types:
         - RAM Memory: 16* 16GB DDR4-3200.
         - Disks: 2* 960GB SATA SSD.
     - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+        - Numa0: (x16, x16, x16 PCIe4.0 lanes)
             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+        - Numa1: (x16, x16, x16 PCIe4.0 lanes)
             - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
+19. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
     - Quantity: 3.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -897,15 +549,15 @@ FD.io CSIT lab contains following server types:
         - RAM Memory: 16* 16GB DDR4-3200.
         - Disks: 2* 960GB SATA SSD.
     - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+        - Numa0: (x16, x16, x16 PCIe4.0 lanes)
             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+        - Numa1: (x16, x16, x16 PCIe4.0 lanes)
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+20. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
     - Quantity: 3.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -917,15 +569,15 @@ FD.io CSIT lab contains following server types:
         - RAM Memory: 16* 16GB DDR4-3200.
         - Disks: 2* 960GB SATA SSD.
     - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+        - Numa0: (x16, x16, x16 PCIe4.0 lanes)
             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
             - PCIe Slot4 3b:00.xx: empty.
             - PCIe Slot9 5e:00.xx: empty.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+        - Numa1: (x16, x16, x16 PCIe4.0 lanes)
             - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
             - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
             - PCIe Slot10 d8:00.xx: empty.
-27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
+21. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
     - Quantity: 2
     - Physical connectivity:
         - IPMI and host management ports.
@@ -939,6 +591,126 @@ FD.io CSIT lab contains following server types:
     - NICs configuration:
         - Numa0: (x16, PCIe3.0 lane)
             - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
+22. Server-Type-H1: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
+    - Quantity: 1.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 3-numa-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-741GE-TNRT.
+        - Motherboard: Super X13DEG-QT-P.
+        - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+        - RAM Memory: 16* 32GB DDR5-4800.
+        - Disks: 2* 960GB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+            - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+            - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+            - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+        - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+            - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+            - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+            - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+23. Server-Type-H2: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
+    - Quantity: 1.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 3-numa-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-741GE-TNRT.
+        - Motherboard: Super X13DEG-QT-P.
+        - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+        - RAM Memory: 16* 32GB DDR5-4800.
+        - Disks: 2* 960GB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+            - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+            - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+            - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+        - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+            - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+            - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+            - PCIe Slot11 d8:00.xx: empty.
+24. Server-Type-H3: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
+    - Quantity: 1.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 3-numa-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-741GE-TNRT.
+        - Motherboard: Super X13DEG-QT-P.
+        - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+        - RAM Memory: 16* 32GB DDR5-4800.
+        - Disks: 2* 960GB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+            - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
+            - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+            - PCIe Slot10 5e:00.xx: empty.
+        - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+            - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel.
+            - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
+            - PCIe Slot11 d8:00.xx: empty.
+25. Server-Type-H4: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
+    - Quantity: 1.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 3-numa-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-741GE-TNRT.
+        - Motherboard: Super X13DEG-QT-P.
+        - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+        - RAM Memory: 16* 32GB DDR5-4800.
+        - Disks: 2* 960GB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+            - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
+            - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+            - PCIe Slot10 5e:00.xx: empty.
+        - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+            - PCIe Slot7 86:00.xx: empty.
+            - PCIe Slot9 af:00.xx: empty.
+            - PCIe Slot11 d8:00.xx: empty.
+26. Server-Type-H5: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
+    - Quantity: 2.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-741GE-TNRT.
+        - Motherboard: Super X13DEG-QT-P.
+        - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+        - RAM Memory: 16* 32GB DDR5-4800.
+        - Disks: 2* 960GB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+            - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+            - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
+            - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
+        - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+            - PCIe Slot7 86:00.xx: empty.
+            - PCIe Slot9 af:00.xx: empty.
+            - PCIe Slot11 d8:00.xx: empty.
+27. Server-Type-H6: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
+    - Quantity: 2.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-741GE-TNRT.
+        - Motherboard: Super X13DEG-QT-P.
+        - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
+        - RAM Memory: 16* 32GB DDR5-4800.
+        - Disks: 2* 960GB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe5.0 lanes)
+            - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+            - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
+            - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
+        - Numa1: (x16, x16, x16 PCIe5.0 lanes)
+            - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
+            - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
+            - PCIe Slot11 d8:00.xx: empty.
 ```
 
 ### Naming Convention
@@ -1051,158 +823,6 @@ connectivity and wiring across defined CSIT testbeds:
         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
 ```
 
-#### 2-Node-Skylake Servers (2n-skx) PROD
-
-```
-- SUT [Server-Type-B1]:
-    - testbedname: testbed21.
-    - hostname: s3-t21-sut1.
-    - IPMI IP: 10.30.50.41
-    - Host IP: 10.30.51.44
-    - portnames:
-        - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
-    - testbedname: testbed21.
-    - hostname: s4-t21-tg1.
-    - IPMI IP: 10.30.50.42
-    - Host IP: 10.30.51.45
-    - portnames:
-        - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B1]:
-    - testbedname: testbed22.
-    - hostname: s5-t22-sut1.
-    - IPMI IP: 10.30.50.49
-    - Host IP: 10.30.51.52
-    - portnames:
-        - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
-    - testbedname: testbed22.
-    - hostname: s6-t22-tg1.
-    - IPMI IP: 10.30.50.50
-    - Host IP: 10.30.51.53
-    - portnames:
-        - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B1]:
-    - testbedname: testbed23.
-    - hostname: s7-t23-sut1.
-    - IPMI IP: 10.30.50.51
-    - Host IP: 10.30.51.54
-    - portnames:
-        - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
-    - testbedname: testbed23.
-    - hostname: s8-t23-tg1.
-    - IPMI IP: 10.30.50.52
-    - Host IP: 10.30.51.55
-    - portnames:
-        - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B1]:
-    - testbedname: testbed24.
-    - hostname: s9-t24-sut1.
-    - IPMI IP: 10.30.50.53
-    - Host IP: 10.30.51.56
-    - portnames:
-        - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
-    - testbedname: testbed24.
-    - hostname: s10-t24-tg1.
-    - IPMI IP: 10.30.50.54
-    - Host IP: 10.30.51.57
-    - portnames:
-        - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 2-Node-Denverton Servers (2n-dnv) PROD
-
-Note: ServerB28 (TG) is shared between testbed26 & testbed35
-
-```
-- TG [Server-Type-B2]:
-    - testbednames: testbed26 and testbed35.
-    - hostname: s28-t26t35-tg1.
-    - IPMI IP: 10.30.55.10
-    - Host IP: 10.32.8.10
-    - portnames:
-        - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
-        - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
-        - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
-        - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
-        - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
-        - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
-        - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
-        - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
-        - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
-        - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
-        - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
-        - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
-- SUT [Server-Type-B10]:
-    - testbednames: testbed26.
-    - hostname: s29-t26-sut1.
-    - IPMI IP: 10.30.55.11
-    - Host IP: 10.32.8.11
-    - portnames:
-        - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
-        - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
-        - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
-        - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
-```
-
 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
 
 ```
@@ -1405,8 +1025,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
 - SUT [Server-Type-F1]:
     - testbedname: testbed212.
     - hostname: s71-t212-sut1.
-    - IPMI IP: 10.30.51.81
-    - Host IP: 10.30.50.81
+    - IPMI IP: 10.30.50.81
+    - Host IP: 10.30.51.81
     - portnames:
         - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
@@ -1419,8 +1039,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
 - TG [Server-Type-F2]:
     - testbedname: testbed212.
     - hostname: s72-t212-tg1.
-    - IPMI IP: 10.30.51.82
-    - Host IP: 10.30.50.82
+    - IPMI IP: 10.30.50.82
+    - Host IP: 10.30.51.82
     - portnames:
         - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
@@ -1435,8 +1055,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
 - SUT [Server-Type-F1]:
     - testbedname: testbed213.
     - hostname: s83-t213-sut1.
-    - IPMI IP: 10.30.51.83
-    - Host IP: 10.30.50.83
+    - IPMI IP: 10.30.50.83
+    - Host IP: 10.30.51.83
     - portnames:
         - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
@@ -1449,8 +1069,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
 - TG [Server-Type-F2]:
     - testbedname: testbed213.
     - hostname: s84-t213-tg1.
-    - IPMI IP: 10.30.51.84
-    - Host IP: 10.30.50.84
+    - IPMI IP: 10.30.50.84
+    - Host IP: 10.30.51.84
     - portnames:
         - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
@@ -1465,8 +1085,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
 - SUT [Server-Type-F1]:
     - testbedname: testbed214.
     - hostname: s85-t214-sut1.
-    - IPMI IP: 10.30.51.85
-    - Host IP: 10.30.50.85
+    - IPMI IP: 10.30.50.85
+    - Host IP: 10.30.51.85
     - portnames:
         - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
@@ -1479,8 +1099,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
 - TG [Server-Type-F2]:
     - testbedname: testbed214.
     - hostname: s86-t214-tg1.
-    - IPMI IP: 10.30.51.86
-    - Host IP: 10.30.50.86
+    - IPMI IP: 10.30.50.86
+    - Host IP: 10.30.51.86
     - portnames:
         - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
@@ -1495,8 +1115,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
 - SUT [Server-Type-F1]:
     - testbedname: testbed215.
     - hostname: s87-t215-sut1.
-    - IPMI IP: 10.30.51.87
-    - Host IP: 10.30.50.87
+    - IPMI IP: 10.30.50.87
+    - Host IP: 10.30.51.87
     - portnames:
         - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
@@ -1509,8 +1129,8 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
 - TG [Server-Type-F2]:
     - testbedname: testbed215.
     - hostname: s88-t215-tg1.
-    - IPMI IP: 10.30.51.88
-    - Host IP: 10.30.50.88
+    - IPMI IP: 10.30.50.88
+    - Host IP: 10.30.51.88
     - portnames:
         - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
@@ -1524,91 +1144,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
         - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 ```
 
-#### 3-Node-Skylake Servers (3n-skx) PROD
-
-```
-- ServerB11 [Server-Type-B1]:
-    - testbedname: testbed31.
-    - hostname: s11-t31-sut1.
-    - IPMI IP: 10.30.50.43
-    - Host IP: 10.30.51.46
-    - portnames:
-        - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB12 [Server-Type-B1]:
-    - testbedname: testbed31.
-    - hostname: s12-t31-sut2.
-    - IPMI IP: 10.30.50.44
-    - Host IP: 10.30.51.47
-    - portnames:
-        - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB13 [Server-Type-B2]:
-    - testbedname: testbed31.
-    - hostname: s13-t31-tg1.
-    - IPMI IP: 10.30.50.45
-    - Host IP: 10.30.51.48
-    - portnames:
-        - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- ServerB14 [Server-Type-B1]:
-    - testbedname: testbed32.
-    - hostname: s14-t32-sut1.
-    - IPMI IP: 10.30.50.55
-    - Host IP: 10.30.51.58
-    - portnames:
-        - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB15 [Server-Type-B1]:
-    - testbedname: testbed32.
-    - hostname: s15-t32-sut2.
-    - IPMI IP: 10.30.50.56
-    - Host IP: 10.30.51.59
-    - portnames:
-        - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB16 [Server-Type-B2]:
-    - testbedname: testbed32.
-    - hostname: s16-t32-tg1.
-    - IPMI IP: 10.30.50.57
-    - Host IP: 10.30.51.60
-    - portnames:
-        - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
 
 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
@@ -1725,31 +1260,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
         - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 ```
 
-#### 3-Node-Denverton Servers (3n-dnv) PROD
-
-```
-- ServerB30 [Server-Type-B10]:
-    - testbednames: testbed35.
-    - hostname: s30-t35-sut1.
-    - IPMI IP: 10.30.55.12
-    - Host IP: 10.32.8.12
-    - portnames:
-        - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
-        - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
-        - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
-        - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
-- ServerB31 [Server-Type-B10]:
-    - testbednames: testbed35.
-    - hostname: s31-t35-sut2.
-    - IPMI IP: 10.30.55.13
-    - Host IP: 10.32.8.13
-    - portnames:
-        - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
-        - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
-        - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
-        - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
-```
-
 #### 3-Node-Icelake Servers (3n-icx) PROD
 
 ```
@@ -1874,6 +1384,107 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
         - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
 ```
 
+#### 2-Node-SapphireRapids Servers (2n-spr) PROD
+
+```
+- SUT [Server-Type-H1]:
+    - testbedname: testbed21.
+    - hostname: s52-t21-sut1.
+    - IPMI IP: 10.30.50.52
+    - Host IP: 10.30.51.52
+    - portnames:
+        - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+        - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+        - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
+        - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
+        - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
+        - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
+        - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
+        - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
+        - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
+        - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
+        - s52-t21-sut1-c11/p1 - 200GE-port1 ConnectX7-2p200GE.
+        - s52-t21-sut1-c11/p2 - 200GE-port2 ConnectX7-2p200GE.
+- TG [Server-Type-H2]:
+    - testbedname: testbed21.
+    - hostname: s53-t21-tg1.
+    - IPMI IP: 10.30.51.53
+    - Host IP: 10.30.50.53
+    - portnames:
+        - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+        - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+        - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
+        - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
+        - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
+        - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
+        - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
+        - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
+        - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
+        - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
+- SUT [Server-Type-H3]:
+    - testbedname: testbed22.
+    - hostname: s54-t22-sut1.
+    - IPMI IP: 10.30.50.54
+    - Host IP: 10.30.51.54
+    - portnames:
+        - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- TG [Server-Type-H4]:
+    - testbedname: testbed22.
+    - hostname: s55-t22-tg1.
+    - IPMI IP: 10.30.51.55
+    - Host IP: 10.30.50.55
+    - portnames:
+        - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- SUT [Server-Type-H5]:
+    - testbedname: testbed23.
+    - hostname: s56-t23-sut1.
+    - IPMI IP: 10.30.50.56
+    - Host IP: 10.30.51.56
+    - portnames:
+        - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+        - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+        - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- TG [Server-Type-H6]:
+    - testbedname: testbed23.
+    - hostname: s57-t23-tg1.
+    - IPMI IP: 10.30.51.57
+    - Host IP: 10.30.50.57
+    - portnames:
+        - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
+        - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
+        - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
+        - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
+        - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+```
+
 ### Per Testbed Wiring
 
 #### 1-Node-Skylake Wiring (1n-skx) PROD
@@ -1931,75 +1542,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
         - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
 ```
 
-#### 2-Node-Skylake Wiring (2n-skx) PROD
-
-```
-- testbed21:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
-        - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
-        - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
-        - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
-    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
-        - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
-- testbed22:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
-        - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
-        - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
-        - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
-    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
-        - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
-- testbed23:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
-        - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
-        - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
-        - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
-    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
-        - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
-- testbed24:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
-        - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
-        - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
-        - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
-    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
-        - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
-```
-
-#### 2-Node-Denverton Wiring (2n-dnv) PROD
-
-```
-- testbed26:
-    - ring1 10GE-ports x553 copper port on SUT:
-        - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
-        - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
-    - ring2 10GE-ports x553 fiber port on SUT:
-        - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
-        - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
-```
-
 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
 
 ```
@@ -2165,51 +1707,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
         - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
 ```
 
-#### 3-Node-Skylake Wiring (3n-skx) PROD
-
-```
-- testbed31:
-    - ring1 10GE-ports x710-4p10GE on SUTs:
-        - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
-        - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
-        - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
-        - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
-        - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
-        - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
-        - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
-        - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
-        - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
-        - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
-- testbed32:
-    - ring1 10GE-ports x710-4p10GE on SUTs:
-        - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
-        - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
-        - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
-        - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
-        - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
-        - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
-        - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
-        - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
-        - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
-        - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
-```
-
 #### 3-Node-Rangeley Wiring (3n-rng) VERIFY
 
 ```
@@ -2240,20 +1737,6 @@ To be completed.
         - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
 ```
 
-#### 3-Node-Denverton Wiring (3n-dnv) PROD
-
-```
-- testbed35:
-    - ring1 10GE-ports x553 copper port on SUTs:
-        - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
-        - s30-t35-sut1-p1 to s31-t35-sut2-p1.
-        - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
-    - ring2 10GE-ports x553 fiber port on SUTs:
-        - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
-        - s30-t35-sut1-p3 to s31-t35-sut2-p3.
-        - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
-```
-
 #### 3-Node-Icelake Wiring (3n-icx) PROD
 
 ```
@@ -2304,117 +1787,8 @@ To be completed.
         - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
 ```
 
-## Inventory
-
-### Appliances
-
-```
-1. Ixia PerfectStorm One Appliance
-    - 1 * PS10GE4NG
-        - Chassis: PS10GE4NG.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: Quad-Core, Intel Processor.
-        - HW accelerators: FPGA offload.
-        - RAM Memory: 64GB.
-        - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
-        - Physical Interfaces: 4 * 10GE SFP+.
-        - Operating System: Native IxOS.
-```
-
-### Arm Servers
-
-```
-1. Arm Cortex A-72 servers
-    - 2 * ThunderX2 (VPP Device)
-        - Chassis: GIGABYTE Rack Mount
-        - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
-        - RAM Memory: 16* 16GB DIMM
-        - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
-    - 1 * ThunderX2 (Performance)
-        - Chassis: GIGABYTE Rack Mount
-        - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
-        - RAM Memory: 4* 32GB RDIMM
-        - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
-    - 2 * Huawei TaiShan 2280.
-        - Chassis: Huawei TaiShan 2280.
-        - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
-        - RAM Memory: 8* 16GB DDR4-2400MT/s.
-        - Disks: 1* 4TB SATA HDD.
-2. Arm Neoverse N1 servers
-    - 2 * Ampere Altra (Performance)
-        - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
-        - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
-        - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
-        - RAM Memory: 16* 8GB DDR4-3200MT/s
-        - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
-    - 2 * Ampere Altra (Build)
-        - Chassis: Gigabyte R152-P30-00 1U
-        - Motherboard: MP32-AR1-00
-        - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
-        - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
-        - RAM Memory: 12* 16GB DDR4-3200MT/s
-        - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
-```
-
-### Xeon and Atom Servers
+#### 2-Node-SapphireRapids Wiring (2n-spr) PROD
 
 ```
-1. Intel Xeon servers:
-    - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.5 GHz.
-        - RAM Memory: 16* 16GB DDR4-2666MHz.
-        - Disks: 2* 1.6TB 6G SATA SSD.
-2. Intel Atom servers with Rangely processors.
-    - 3 * Netgate XG-2758-1u
-        - Chassis: Netgate XG-2758-1u
-        - Processors: 1* Rangely (Atom) C2758 2.4 GHz
-        - RAM Memory: 16GB ECC
-        - Disks: 150 GB
-```
-
-### Network Interface Cards
-
-```
-1. 10GE NICs
-    - ?
-2. 25GE NICs
-    - ?
-3. 40GE NICs
-    - ?
-4. 100GE NICs
-    - ?
-```
-
-### Pluggables and Cables
-
-Pluggables:
-
-```
-1. 10GE SFP+
-    - ?
-2. 25GE SFP28
-    - ?
-3. 40GE QSFP+
-    - ?
-4. 100GE
-    - ?
-```
-
-Standalone cables:
-
-```
-1. 10GE
-    - ?
-2. 25GE
-    - ?
-3. 40GE QSFP+
-    - ?
-4. 100GE
-    - ?
-```
-
-### Other Parts
-
-None.
+TBD
+```
\ No newline at end of file