feat(core): DNV decommission
[csit.git] / docs / lab / testbed_specifications.md
index 196c956..8b40248 100644 (file)
@@ -6,14 +6,11 @@
    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
-   1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
-   1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
    1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
    1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
    1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
-   1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
    1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
       1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
       1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
-      1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
-      1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
       1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
       1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
       1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
       1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
-      1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
       1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
       1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
       1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
       1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
-      1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
-      1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
       1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
       1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
       1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
-      1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
       1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
       1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
       1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
@@ -80,27 +71,26 @@ hosted by LFN FD.io CSIT project.
 ### Summary List
 
 ```
- #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx #snr
- 1. 1-Node-Haswell     nomad  hsw   na    4    4    0    4    0    0    0    0    0    0    0    0    0    0    0
- 2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0    0    0    0
- 3. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0    0    0    0
- 4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0    1    0    0    0
- 5. 1-Node-AmpereAltra nomad  alt   na    2    2    0    0    0    0    0    0    0    0    2    0    0    0    0
- 6. 2-Node-Skylake     perf   skx   skx   3    3    3    0    6    0    0    0    0    0    0    0    0    0    0
- 7. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0    0    0    0
- 8. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0    0    0    0
- 9. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0    6    0    0    0
-10. 2-Node-ThunderX2   perf   tx2   skx   1    1    .5   0    .5   0    0    0    1    0    0    0    0    0    0
-11. 2-Node-Icelake     perf   icx   icx   4    4    4    0    0    0    0    0    0    0    0    0    0    8    0
-12. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0    0    0    0
-13. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0    0    0    0
-14. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0    0    0    0
-15. 3-Node-Altra       perf   alt   icx   1    2    .5   0    0    0    0    0    0    0    2    0    0    .5   0
-16. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0    0    0    0
-17. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    0    2    0    0
-18. 3-Node-Icelake     perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    0    0    6    0
-19. 3-Node-SnowRidge   perf   snr   icx   1    2    .5   0    0    0    0    0    0    0    0    0    0    .5   2
-                                 Totals: 34   44   21    4   17    1    2    3    3    2    4    7    2   15    2
+ #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr
+ 1. 1-Node-Haswell     nomad  hsw   na    4    4    0    4    0    0    0    0    0    0    0    0    0    0
+ 2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0    0    0
+ 3. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    2    0    0    0    0    0    0
+ 4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    1    0    0    0
+ 5. 1-Node-AmpereAltra nomad  alt   na    2    2    0    0    0    0    0    0    0    2    0    0    0    0
+ 6. 2-Node-Skylake     perf   skx   skx   3    3    3    0    6    0    0    0    0    0    0    0    0    0
+ 7. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    0    0    0    0    0    0    0
+ 8. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0    0    0
+ 9. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    6    0    0    0
+10. 2-Node-ThunderX2   perf   tx2   skx   1    1    .5   0    .5   0    0    1    0    0    0    0    0    0
+11. 2-Node-Icelake     perf   icx   icx   4    4    4    0    0    0    0    0    0    0    0    0    8    0
+12. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0    0    0
+13. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0    0    0
+14. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    2    0    0    0    0    0
+15. 3-Node-Altra       perf   alt   icx   1    2    1    0    0    0    0    0    0    2    0    0    1    0
+17. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    2    0    0
+18. 3-Node-Icelake     perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    0    6    0
+19. 3-Node-SnowRidge   perf   snr   icx   1    2    .5   0    0    0    0    0    0    0    0    0    .5   2
+                                 Totals: 32   41  20.5   4   17    1    2    3    2    4    7    2  15.5   2
 ```
 
 ### 1-Node-Skylake Xeon Intel (1n-skx)
@@ -122,20 +112,6 @@ NIC ports connected back-to-back ([Server Types](#server-types)).
 
 Used for FD.io VPP_Device functional driver tests.
 
-### 2-Node-Skylake Xeon Intel (2n-skx)
-
-Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
-(Server-Type-B2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-Denverton Atom Intel (2n-dnv)
-
-Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
-TG (Server-Type-B2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
 
 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
@@ -178,12 +154,6 @@ TG (Server-Type-A2) connected in a 3-node circular topology
 ([Server Types](#server-types)).
 Used for FD.io performance tests.
 
-### 3-Node-Skylake Xeon Intel (3n-skx)
-
-Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
-TG (Server-Type-B2) connected in a 3-node circular topology.
-Used for FD.io performance tests.
-
 ### 3-Node-Rangeley Atom Testbeds
 
 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
@@ -278,21 +248,20 @@ Name         | Comment
 10.30.50.13  | LF Reserved
 10.30.50.14  | LF Reserved
 10.30.50.15  | LF Reserved
-10.30.50.22  | s42-nomad
-10.30.50.24  | s43-nomad
-10.30.50.25  | s44-nomad
-10.30.50.26  | s45-nomad
-10.30.50.28  | s41-nomad
-10.30.50.29  | s39-nomad
-10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
-10.30.50.30  | s40-nomad
-10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
-10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
+10.30.50.16  | s16-nomad
+10.30.50.17  | s17-nomad
+10.30.50.18  | s18-nomad
+10.30.50.19  | s19-nomad
+10.30.50.20  | s20-nomad
+10.30.50.21  | s21-nomad
+10.30.50.22  | s22-nomad
+10.30.50.23  | s23-nomad
+10.30.50.24  | s24-nomad
+10.30.50.25  | s25-nomad
+10.30.50.26  | s26-nomad
 10.30.50.36  | s17-t33-sut1
 10.30.50.37  | s18-t33-sut2
 10.30.50.38  | fdio-marvell-dev
-10.30.50.39  | s53-nomad
-10.30.50.40  | s54-nomad
 10.30.50.41  | s3-t21-sut1
 10.30.50.42  | s4-t21-tg1
 10.30.50.43  | s11-t31-sut1
@@ -312,16 +281,12 @@ Name         | Comment
 10.30.50.57  | s16-t32-tg1
 10.30.50.58  | s25-t25-sut1
 10.30.50.59  | s26-t25-tg1
-10.30.50.65  | s52-nomad
-10.30.50.66  | s51-nomad
-10.30.50.67  | s49-nomad
-10.30.50.68  | s50-nomad
 10.30.50.69  | s27-t211-sut1
 10.30.50.70  | s55-t13-sut1
 10.30.50.71  | s56-t14-sut1
 10.30.50.72  | s62-t34-sut1
 10.30.50.73  | s63-t34-sut2
-10.30.50.74  | s64-t34t36-tg1
+10.30.50.74  | s64-t34-tg1
 10.30.50.75  | s65-t37-sut1
 10.30.50.76  | s66-t37-sut2
 10.30.50.77  | s67-t37-tg1
@@ -338,8 +303,8 @@ Name         | Comment
 10.30.50.88  | s88-t215-tg1
 10.30.50.89  | s89-t39t310-tg1
 10.30.50.90  | s90-t311t312-tg1
-10.30.50.91  | s58-nomad
-10.30.50.92  | s59-nomad
+10.30.50.91  | s91-nomad
+10.30.50.92  | s92-nomad
 10.30.50.93  | s93-t39-sut1
 10.30.50.94  | s94-t39-sut2
 10.30.50.255 | Broadcast
@@ -349,10 +314,6 @@ Name         | Comment
 10.30.55.11  | s29-t26-sut1
 10.30.55.12  | s30-t35-sut1
 10.30.55.13  | s31-t35-sut2
-10.30.55.14  | s46-nomad
-10.30.55.15  | s47-nomad
-10.30.55.16  | s48-nomad
-10.30.55.17  | s57-nomad
 10.30.55.18  | s33-t27-sut1
 10.30.55.19  | s34-t27-tg1
 10.30.55.20  | s35-t28-sut1
@@ -377,18 +338,20 @@ Name         | Comment
 10.30.51.7   | LF Reserved
 10.30.51.8   | LF Reserved
 10.30.51.15  | LF Reserved
-10.30.51.22  | s42-nomad
-10.30.51.24  | s43-nomad
-10.30.51.25  | s44-nomad
-10.30.51.26  | s45-nomad
-10.30.51.28  | s41-nomad
-10.30.51.29  | s39-nomad
-10.30.51.30  | s40-nomad
+10.30.51.16  | s16-nomad
+10.30.51.17  | s17-nomad
+10.30.51.18  | s18-nomad
+10.30.51.19  | s19-nomad
+10.30.51.20  | s20-nomad
+10.30.51.21  | s21-nomad
+10.30.51.22  | s22-nomad
+10.30.51.23  | s23-nomad
+10.30.51.24  | s24-nomad
+10.30.51.25  | s25-nomad
+10.30.51.26  | s26-nomad
 10.30.51.36  | s17-t33-sut1
 10.30.51.37  | s18-t33-sut2
 10.30.51.38  | fdio-marvell-dev
-10.30.51.39  | s53-nomad
-10.30.51.40  | s54-nomad
 10.30.51.44  | s3-t21-sut1
 10.30.51.45  | s4-t21-tg1
 10.30.51.46  | s11-t31-sut1
@@ -408,16 +371,12 @@ Name         | Comment
 10.30.51.60  | s16-t32-tg1
 10.30.51.61  | s25-t25-sut1
 10.30.51.62  | s26-t25-tg1
-10.30.51.65  | s52-nomad
-10.30.51.66  | s51-nomad
-10.30.51.67  | s49-nomad
-10.30.51.68  | s50-nomad
 10.30.51.69  | s27-t211-sut1
 10.30.51.70  | s55-t13-sut1
 10.30.51.71  | s56-t14-sut1
 10.30.51.72  | s62-t34-sut1
 10.30.51.73  | s63-t34-sut2
-10.30.51.74  | s64-t34t36-tg1
+10.30.51.74  | s64-t34-tg1
 10.30.51.75  | s65-t37-sut1
 10.30.51.76  | s66-t37-sut2
 10.30.51.77  | s67-t37-tg1
@@ -434,8 +393,8 @@ Name         | Comment
 10.30.51.88  | s88-t215-tg1
 10.30.51.89  | s89-t39t310-tg1
 10.30.51.90  | s90-t311t312-tg1
-10.30.51.91  | s58-nomad
-10.30.51.92  | s59-nomad
+10.30.51.91  | s91-nomad
+10.30.51.92  | s92-nomad
 10.30.51.93  | s93-t39-sut1
 10.30.51.94  | s94-t39-sut2
 10.30.51.255 | Broadcast
@@ -445,10 +404,6 @@ Name         | Comment
 10.32.8.11   | s29-t26-sut1
 10.32.8.12   | s30-t35-sut1
 10.32.8.13   | s31-t35-sut2
-10.32.8.14   | s46-nomad
-10.32.8.15   | s47-nomad
-10.32.8.16   | s48-nomad
-10.32.8.17   | s57-nomad
 10.32.8.18   | s33-t27-sut1
 10.32.8.19   | s34-t27-tg1
 10.32.8.20   | s35-t28-sut1
@@ -797,28 +752,38 @@ FD.io CSIT lab contains following server types:
         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
     - NICs configuration:
         - Numa0:
-            - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
+            - no cards
         - Numa1:
             - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
 20.  Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
-    - Quantity: 1
+    - Quantity: 2
     - Physical connectivity:
         - IPMI and host management ports.
         - NIC ports connected into 3-node topologies.
     - Main HW configuration:
-        - Chassis: TBD
-        - Motherboard: TBD
-        - Processors: n* TBD
-        - RAM Memory: n* TBD
-        - Disks: TBD
+        - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
+        - Motherboard: Mt.Jade Motherboard
+        - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
+        - RAM Memory: 16* 8GB DDR4-3200MT/s
+        - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
     - NICs configuration:
         - Numa0:
-            - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
-            - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
+            - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
         - Numa1:
-            - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
-            - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-21.  Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
+            - no cards.
+21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
+    - Quantity: 2.
+    - Physical connectivity:
+        - IPMI and host management ports.
+    - Main HW configuration:
+        - Chassis: Gigabyte R152-P30-00 1U
+        - Motherboard: MP32-AR1-00
+        - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
+        - RAM Memory: 12* 16GB DDR4-3200MT/s
+        - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
+22.  Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
     - Quantity: 1
     - Physical connectivity:
         - IPMI and host management ports.
@@ -838,7 +803,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-22. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
+23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
     - Quantity: 8.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -858,7 +823,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-23. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
+24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
     - Quantity: 3.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -878,7 +843,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-24. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
+25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
     - Quantity: 3.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -898,7 +863,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-25. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
     - Quantity: 3.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -918,30 +883,20 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
             - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
             - PCIe Slot10 d8:00.xx: empty.
-26. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
-    - Quantity: 2.
-    - Physical connectivity:
-        - IPMI and host management ports.
-    - Main HW configuration:
-        - Chassis: Gigabyte R152-P30-00 1U
-        - Motherboard: MP32-AR1-00
-        - Processors: 1* Ampere(R) Altra(R) Processor (Neoverse N1)
-        - RAM Memory: 4* 16GB RDIMM-3200MHz
-        - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
 27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
     - Quantity: 2
     - Physical connectivity:
         - IPMI and host management ports.
         - NIC ports connected into 3-node testbed topology.
     - Main HW configuration:
-        - Chassis: ?.
-        - Motherboard: ?.
-        - Processors: ?* Intel Atom P5362B 2.2 GHz.
-        - RAM Memory: ?* ?GB DDR4-2933.
+        - Chassis: Intel JACOBSVILLE SDP.
+        - Motherboard: Intel JACOBSVILLE E63448-400.
+        - Processors: 1* Intel Atom P5362B 2.2 GHz.
+        - RAM Memory: 2* 16GB DDR4-2933.
         - Disks: ?* ? SATA SSD.
     - NICs configuration:
         - Numa0: (x16, PCIe3.0 lane)
-            - PCIe Slot yy:00.xx: ?.
+            - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
 ```
 
 ### Naming Convention
@@ -1054,158 +1009,6 @@ connectivity and wiring across defined CSIT testbeds:
         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
 ```
 
-#### 2-Node-Skylake Servers (2n-skx) PROD
-
-```
-- SUT [Server-Type-B1]:
-    - testbedname: testbed21.
-    - hostname: s3-t21-sut1.
-    - IPMI IP: 10.30.50.41
-    - Host IP: 10.30.51.44
-    - portnames:
-        - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
-    - testbedname: testbed21.
-    - hostname: s4-t21-tg1.
-    - IPMI IP: 10.30.50.42
-    - Host IP: 10.30.51.45
-    - portnames:
-        - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B1]:
-    - testbedname: testbed22.
-    - hostname: s5-t22-sut1.
-    - IPMI IP: 10.30.50.49
-    - Host IP: 10.30.51.52
-    - portnames:
-        - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
-    - testbedname: testbed22.
-    - hostname: s6-t22-tg1.
-    - IPMI IP: 10.30.50.50
-    - Host IP: 10.30.51.53
-    - portnames:
-        - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B1]:
-    - testbedname: testbed23.
-    - hostname: s7-t23-sut1.
-    - IPMI IP: 10.30.50.51
-    - Host IP: 10.30.51.54
-    - portnames:
-        - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
-    - testbedname: testbed23.
-    - hostname: s8-t23-tg1.
-    - IPMI IP: 10.30.50.52
-    - Host IP: 10.30.51.55
-    - portnames:
-        - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B1]:
-    - testbedname: testbed24.
-    - hostname: s9-t24-sut1.
-    - IPMI IP: 10.30.50.53
-    - Host IP: 10.30.51.56
-    - portnames:
-        - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- TG [Server-Type-B2]:
-    - testbedname: testbed24.
-    - hostname: s10-t24-tg1.
-    - IPMI IP: 10.30.50.54
-    - Host IP: 10.30.51.57
-    - portnames:
-        - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 2-Node-Denverton Servers (2n-dnv) PROD
-
-Note: ServerB28 (TG) is shared between testbed26 & testbed35
-
-```
-- TG [Server-Type-B2]:
-    - testbednames: testbed26 and testbed35.
-    - hostname: s28-t26t35-tg1.
-    - IPMI IP: 10.30.55.10
-    - Host IP: 10.32.8.10
-    - portnames:
-        - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
-        - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
-        - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
-        - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
-        - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
-        - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
-        - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
-        - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
-        - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
-        - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
-        - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
-        - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
-- SUT [Server-Type-B10]:
-    - testbednames: testbed26.
-    - hostname: s29-t26-sut1.
-    - IPMI IP: 10.30.55.11
-    - Host IP: 10.32.8.11
-    - portnames:
-        - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
-        - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
-        - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
-        - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
-```
-
 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
 
 ```
@@ -1380,8 +1183,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
     - IPMI IP: 10.30.50.69
     - Host IP: 10.30.51.69
     - portnames:
-        - s27-t211-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s27-t211-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
         - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
         - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
 - TG [Server-Type-E31]:
@@ -1529,91 +1330,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
         - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 ```
 
-#### 3-Node-Skylake Servers (3n-skx) PROD
-
-```
-- ServerB11 [Server-Type-B1]:
-    - testbedname: testbed31.
-    - hostname: s11-t31-sut1.
-    - IPMI IP: 10.30.50.43
-    - Host IP: 10.30.51.46
-    - portnames:
-        - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB12 [Server-Type-B1]:
-    - testbedname: testbed31.
-    - hostname: s12-t31-sut2.
-    - IPMI IP: 10.30.50.44
-    - Host IP: 10.30.51.47
-    - portnames:
-        - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB13 [Server-Type-B2]:
-    - testbedname: testbed31.
-    - hostname: s13-t31-tg1.
-    - IPMI IP: 10.30.50.45
-    - Host IP: 10.30.51.48
-    - portnames:
-        - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- ServerB14 [Server-Type-B1]:
-    - testbedname: testbed32.
-    - hostname: s14-t32-sut1.
-    - IPMI IP: 10.30.50.55
-    - Host IP: 10.30.51.58
-    - portnames:
-        - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB15 [Server-Type-B1]:
-    - testbedname: testbed32.
-    - hostname: s15-t32-sut2.
-    - IPMI IP: 10.30.50.56
-    - Host IP: 10.30.51.59
-    - portnames:
-        - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-- ServerB16 [Server-Type-B2]:
-    - testbedname: testbed32.
-    - hostname: s16-t32-tg1.
-    - IPMI IP: 10.30.50.57
-    - Host IP: 10.30.51.60
-    - portnames:
-        - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
 
 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
@@ -1695,8 +1411,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
 
 #### 3-Node-Altra Servers (3n-alt) PROD
 
-Note: Server64 (TG) is shared between testbed34 & testbed36
-
 ```
 - SUT [Server-Type-E23]:
     - testbedname: testbed34.
@@ -1704,53 +1418,32 @@ Note: Server64 (TG) is shared between testbed34 & testbed36
     - IPMI IP: 10.30.50.72
     - Host IP: 10.30.51.72
     - portnames:
-        - s62-t34-sut1-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
-        - s62-t34-sut1-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
-        - s62-t34-sut1-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s62-t34-sut1-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
+        - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
 - SUT [Server-Type-E23]:
     - testbedname: testbed34.
     - hostname: s63-t34-sut2.
     - IPMI IP: 10.30.50.73
     - Host IP: 10.30.51.73
     - portnames:
-        - s63-t34-sut2-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
-        - s63-t34-sut2-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
-        - s63-t34-sut2-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s63-t34-sut2-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
+        - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
 - TG [Server-Type-F4]:
     - testbedname: testbed34.
-    - hostname: s64-t34t36-tg1.
+    - hostname: s64-t34-tg1.
     - IPMI IP: 10.30.50.74
     - Host IP: 10.30.51.74
     - portnames:
-        - s64-t34-tg1-c1/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s64-t34-tg1-c1/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-```
-
-#### 3-Node-Denverton Servers (3n-dnv) PROD
-
-```
-- ServerB30 [Server-Type-B10]:
-    - testbednames: testbed35.
-    - hostname: s30-t35-sut1.
-    - IPMI IP: 10.30.55.12
-    - Host IP: 10.32.8.12
-    - portnames:
-        - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
-        - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
-        - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
-        - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
-- ServerB31 [Server-Type-B10]:
-    - testbednames: testbed35.
-    - hostname: s31-t35-sut2.
-    - IPMI IP: 10.30.55.13
-    - Host IP: 10.32.8.13
-    - portnames:
-        - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
-        - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
-        - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
-        - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
+        - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+        - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 ```
 
 #### 3-Node-Icelake Servers (3n-icx) PROD
@@ -1851,24 +1544,30 @@ Note: Server64 (TG) is shared between testbed34 & testbed36
     - IPMI IP: 10.30.50.93
     - Host IP: 10.30.51.93
     - portnames:
-        - s93-t39-sut1-c1/p1 - 100GE-port1 e810-DA2-2p100GE.
-        - s93-t39-sut1-c1/p2 - 100GE-port2 e810-DA2-2p100GE.
+        - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
 - ServerG1 [Server-Type-G1]:
     - testbedname: testbed39.
     - hostname: s94-t39-sut2.
     - IPMI IP: 10.30.50.94
     - Host IP: 10.30.51.94
     - portnames:
-        - s94-t39-sut2-c1/p1 - 100GE-port1 e810-DA2-2p100GE.
-        - s94-t39-sut2-c1/p2 - 100GE-port1 e810-DA2-2p100GE.
+        - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
 - ServerF4 [Server-Type-F4]:
     - testbedname: testbed39.
     - hostname: s89-t39t310-tg1.
     - IPMI IP: 10.30.50.89
     - Host IP: 10.30.51.89
     - portnames:
-        - s89-t39t310-tg1-c6/p1 - 100GE-port1 e810-DA2-2p100GE.
-        - s89-t39t310-tg1-c6/p2 - 100GE-port1 e810-DA2-2p100GE.
+        - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
 ```
 
 ### Per Testbed Wiring
@@ -1928,75 +1627,6 @@ Note: Server64 (TG) is shared between testbed34 & testbed36
         - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
 ```
 
-#### 2-Node-Skylake Wiring (2n-skx) PROD
-
-```
-- testbed21:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
-        - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
-        - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
-        - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
-    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
-        - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
-- testbed22:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
-        - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
-        - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
-        - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
-    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
-        - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
-- testbed23:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
-        - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
-        - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
-        - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
-    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
-        - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
-- testbed24:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
-        - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
-        - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
-        - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
-    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
-        - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
-```
-
-#### 2-Node-Denverton Wiring (2n-dnv) PROD
-
-```
-- testbed26:
-    - ring1 10GE-ports x553 copper port on SUT:
-        - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
-        - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
-    - ring2 10GE-ports x553 fiber port on SUT:
-        - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
-        - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
-```
-
 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
 
 ```
@@ -2162,51 +1792,6 @@ Note: Server64 (TG) is shared between testbed34 & testbed36
         - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
 ```
 
-#### 3-Node-Skylake Wiring (3n-skx) PROD
-
-```
-- testbed31:
-    - ring1 10GE-ports x710-4p10GE on SUTs:
-        - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
-        - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
-        - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
-        - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
-        - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
-        - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
-        - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
-        - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
-        - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
-        - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
-- testbed32:
-    - ring1 10GE-ports x710-4p10GE on SUTs:
-        - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
-        - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
-        - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
-        - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
-        - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
-        - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
-        - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
-        - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
-        - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
-        - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
-        - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
-```
-
 #### 3-Node-Rangeley Wiring (3n-rng) VERIFY
 
 ```
@@ -2232,27 +1817,9 @@ To be completed.
 ```
 - testbed34:
     - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
-        - s64-t34-tg1-cn/p2 - s62-t34-sut1-cn/p2.
-        - s62-t34-sut1-cn/p1 - s63-t34-sut2-cn/p2.
-        - s63-t34-sut2-cn/p1 - s64-t34-tg1-cn/p1.
-    - ring2 100GE-ports ConnectX5-2p100GE on SUTs:
-        - s64-t34-tg1-ck/p2 - s62-t34-sut1-ck/p2.
-        - s62-t34-sut1-ck/p1 - s63-t34-sut2-ckp2.
-        - s63-t34-sut2-ck/p1 - s64-t34-tg1-ck/p1.
-```
-
-#### 3-Node-Denverton Wiring (3n-dnv) PROD
-
-```
-- testbed35:
-    - ring1 10GE-ports x553 copper port on SUTs:
-        - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
-        - s30-t35-sut1-p1 to s31-t35-sut2-p1.
-        - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
-    - ring2 10GE-ports x553 fiber port on SUTs:
-        - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
-        - s30-t35-sut1-p3 to s31-t35-sut2-p3.
-        - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
+        - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
+        - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
+        - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
 ```
 
 #### 3-Node-Icelake Wiring (3n-icx) PROD
@@ -2296,10 +1863,13 @@ To be completed.
 
 ```
 - testbed39:
-    - ring1 100GE-ports e810-DA2-2p100GE on SUTs and TG:
+    - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
         - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
         - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
         - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
+        - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
+        - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
+        - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
 ```
 
 ## Inventory
@@ -2338,11 +1908,20 @@ To be completed.
         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
         - RAM Memory: 8* 16GB DDR4-2400MT/s.
         - Disks: 1* 4TB SATA HDD.
-    - 2 * Ampere Altra
-        - Chassis: TBD
-        - Processors: TBD
-        - RAM Memory: TBD
-        - Disks: TBD
+2. Arm Neoverse N1 servers
+    - 2 * Ampere Altra (Performance)
+        - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
+        - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
+        - RAM Memory: 16* 8GB DDR4-3200MT/s
+        - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
+    - 2 * Ampere Altra (Build)
+        - Chassis: Gigabyte R152-P30-00 1U
+        - Motherboard: MP32-AR1-00
+        - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
+        - RAM Memory: 12* 16GB DDR4-3200MT/s
+        - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
 ```
 
 ### Xeon and Atom Servers
@@ -2367,15 +1946,13 @@ To be completed.
 
 ```
 1. 10GE NICs
-    - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
-    - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
-    - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
+    - ?
 2. 25GE NICs
-    - 12 * Intel® Ethernet Network Adapter XXV710-DA2
+    - ?
 3. 40GE NICs
-    - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
+    - ?
 4. 100GE NICs
-    - 4 * mcx556a-edat NICs (not on site yet, in transit)
+    - ?
 ```
 
 ### Pluggables and Cables
@@ -2384,27 +1961,26 @@ Pluggables:
 
 ```
 1. 10GE SFP+
-    - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
-    - 80 * 10G SR optic (generic, "Intel" compatible branded)
+    - ?
 2. 25GE SFP28
-    - None
+    - ?
 3. 40GE QSFP+
-    - None
+    - ?
 4. 100GE
-    - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
+    - ?
 ```
 
 Standalone cables:
 
 ```
 1. 10GE
-    - None
+    - ?
 2. 25GE
-    - None
+    - ?
 3. 40GE QSFP+
-    - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
+    - ?
 4. 100GE
-    - None
+    - ?
 ```
 
 ### Other Parts