feat(pxe): Migrate Ubuntu Jammy I.
[csit.git] / docs / lab / testbed_specifications.md
index 30343aa..fad1bdc 100644 (file)
@@ -18,6 +18,7 @@
    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
    1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
    1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
+   1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
 1. [Server Management](#server-management)
    1. [Requirements](#requirements)
    1. [Addressing](#addressing)
       1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
       1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
       1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
-      1. [2-Node-Icelake Servers (2n-icx) TBD](#2-node-icelake-servers-2n-icx-tbd)
+      1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
       1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
-      1. [3-Node-Altra Servers (3n-alt) TBD](#3-node-altra-servers-3n-alt-tbd)
-      1. [3-Node-Icelake Servers (3n-icx) TBD](#3-node-icelake-servers-3n-icx-tbd)
+      1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
+      1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
+      1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
    1. [Per Testbed Wiring](#per-testbed-wiring)
       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
       1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
       1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
       1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
-      1. [2-Node-Icelake Servers (2n-icx) TBD](#2-node-icelake-servers-2n-icx-tbd)
+      1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
-      1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
+      1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
       1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
-      1. [3-Node-Altra Wiring (3n-alt) TBD](#3-node-altra-wiring-3n-alt-tbd)
-      1. [3-Node-Icelake Wiring (3n-icx) TBD](#3-node-icelake-wiring-3n-icx-tbd)
+      1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
+      1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
+      1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
 1. [Inventory](#inventory)
    1. [Appliances](#appliances)
    1. [Arm Servers](#arm-servers)
@@ -77,25 +80,27 @@ hosted by LFN FD.io CSIT project.
 ### Summary List
 
 ```
- #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx
- 1. 1-Node-Haswell     nomad  hsw   na    4    4    0    4    0    0    0    0    0    0    0    0    0    0
- 2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0    0    0
- 3. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0    0    0
- 4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0    1    0    0
- 5. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0    0    0    0
- 6. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0    0    0
- 7. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0    0    0
- 8. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0    6    0    0
- 9. 2-Node-ThunderX2   perf   tx2   skx   1    1    .5   0    .5   0    0    0    1    0    0    0    0    0
-10. 2-Node-Icelake     perf   icx   icx   4    4    4    0    0    0    0    0    0    0    0    0    0    8
-11. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0    0    0
-12. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0    0    0
-13. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0    0    0
-14. 3-Node-Altra       perf   alt   icx   1    2    .5   0    0    0    0    0    0    0    2    0    0    .5
-15. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0    0    0
-16. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    0    2    0
-17. 3-Node-Icelake     perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    6    0    6
-                                 Totals: 32   41  21.5   4   19    1    2    3    3    2    2    7    2  14.5
+ #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx #snr
+ 1. 1-Node-Haswell     nomad  hsw   na    4    4    0    4    0    0    0    0    0    0    0    0    0    0    0
+ 2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0    0    0    0
+ 3. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0    0    0    0
+ 4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0    1    0    0    0
+ 5. 1-Node-AmpereAltra nomad  alt   na    2    2    0    0    0    0    0    0    0    0    2    0    0    0    0
+ 6. 2-Node-Skylake     perf   skx   skx   3    3    3    0    6    0    0    0    0    0    0    0    0    0    0
+ 7. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0    0    0    0
+ 8. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0    0    0    0
+ 9. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0    6    0    0    0
+10. 2-Node-ThunderX2   perf   tx2   skx   1    1    .5   0    .5   0    0    0    1    0    0    0    0    0    0
+11. 2-Node-Icelake     perf   icx   icx   4    4    4    0    0    0    0    0    0    0    0    0    0    8    0
+12. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0    0    0    0
+13. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0    0    0    0
+14. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0    0    0    0
+15. 3-Node-Altra       perf   alt   icx   1    2    1    0    0    0    0    0    0    0    2    0    0    1    0
+16. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0    0    0    0
+17. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    0    2    0    0
+18. 3-Node-Icelake     perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    0    0    6    0
+19. 3-Node-SnowRidge   perf   snr   icx   1    2    .5   0    0    0    0    0    0    0    0    0    0    .5   2
+                                 Totals: 34   44  21.5   4   17    1    2    3    3    2    4    7    2  15.5   2
 ```
 
 ### 1-Node-Skylake Xeon Intel (1n-skx)
@@ -207,6 +212,14 @@ TG (Server-Type-F3) connected in a 3-node circular topology
 ([Server Types](#server-types)).
 Used for FD.io performance tests.
 
+### 3-Node-SnowRidge Atom Intel (3n-snr)
+
+Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
+TG (Server-Type-F4) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+
 ## Server Management
 
 ### Requirements
@@ -265,16 +278,17 @@ Name         | Comment
 10.30.50.13  | LF Reserved
 10.30.50.14  | LF Reserved
 10.30.50.15  | LF Reserved
-10.30.50.22  | s42-nomad
-10.30.50.24  | s43-nomad
-10.30.50.25  | s44-nomad
-10.30.50.26  | s45-nomad
-10.30.50.28  | s41-nomad
-10.30.50.29  | s39-nomad
-10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
-10.30.50.30  | s40-nomad
-10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
-10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
+10.30.50.16  | s16-nomad
+10.30.50.17  | s17-nomad
+10.30.50.18  | s18-nomad
+10.30.50.19  | s19-nomad
+10.30.50.20  | s20-nomad
+10.30.50.21  | s21-nomad
+10.30.50.22  | s22-nomad
+10.30.50.23  | s23-nomad
+10.30.50.24  | s24-nomad
+10.30.50.25  | s25-nomad
+10.30.50.26  | s26-nomad
 10.30.50.36  | s17-t33-sut1
 10.30.50.37  | s18-t33-sut2
 10.30.50.38  | fdio-marvell-dev
@@ -308,23 +322,27 @@ Name         | Comment
 10.30.50.71  | s56-t14-sut1
 10.30.50.72  | s62-t34-sut1
 10.30.50.73  | s63-t34-sut2
-10.30.50.74  | s64-t34t36-tg1
+10.30.50.74  | s64-t34-tg1
 10.30.50.75  | s65-t37-sut1
 10.30.50.76  | s66-t37-sut2
 10.30.50.77  | s67-t37-tg1
-10.30.50.78  | s68-t38-sut1
-10.30.50.79  | s69-t38-sut2
-10.30.50.80  | s70-t38-tg1
+10.30.50.78  | s78-t38-sut1
+10.30.50.79  | s79-t38-sut2
+10.30.50.80  | s80-t38-tg1
 10.30.50.81  | s71-t212-sut1
 10.30.50.82  | s72-t212-tg1
-10.30.50.83  | s73-t213-sut1
-10.30.50.84  | s74-t213-tg1
-10.30.50.85  | s75-t214-sut1
-10.30.50.86  | s76-t214-tg1
-10.30.50.87  | s77-t215-sut1
-10.30.50.88  | s78-t215-tg1
-10.30.50.89  | s79-t39t310-tg1
-10.30.50.90  | s80-t311t312-tg1
+10.30.50.83  | s83-t213-sut1
+10.30.50.84  | s84-t213-tg1
+10.30.50.85  | s85-t214-sut1
+10.30.50.86  | s86-t214-tg1
+10.30.50.87  | s87-t215-sut1
+10.30.50.88  | s88-t215-tg1
+10.30.50.89  | s89-t39t310-tg1
+10.30.50.90  | s90-t311t312-tg1
+10.30.50.91  | s58-nomad
+10.30.50.92  | s59-nomad
+10.30.50.93  | s93-t39-sut1
+10.30.50.94  | s94-t39-sut2
 10.30.50.255 | Broadcast
 10.30.55.0   | network
 10.30.55.1   | Router
@@ -332,10 +350,6 @@ Name         | Comment
 10.30.55.11  | s29-t26-sut1
 10.30.55.12  | s30-t35-sut1
 10.30.55.13  | s31-t35-sut2
-10.30.55.14  | s46-nomad
-10.30.55.15  | s47-nomad
-10.30.55.16  | s48-nomad
-10.30.55.17  | s57-nomad
 10.30.55.18  | s33-t27-sut1
 10.30.55.19  | s34-t27-tg1
 10.30.55.20  | s35-t28-sut1
@@ -360,13 +374,17 @@ Name         | Comment
 10.30.51.7   | LF Reserved
 10.30.51.8   | LF Reserved
 10.30.51.15  | LF Reserved
-10.30.51.22  | s42-nomad
-10.30.51.24  | s43-nomad
-10.30.51.25  | s44-nomad
-10.30.51.26  | s45-nomad
-10.30.51.28  | s41-nomad
-10.30.51.29  | s39-nomad
-10.30.51.30  | s40-nomad
+10.30.51.16  | s16-nomad
+10.30.51.17  | s17-nomad
+10.30.51.18  | s18-nomad
+10.30.51.19  | s19-nomad
+10.30.51.20  | s20-nomad
+10.30.51.21  | s21-nomad
+10.30.51.22  | s22-nomad
+10.30.51.23  | s23-nomad
+10.30.51.24  | s24-nomad
+10.30.51.25  | s25-nomad
+10.30.51.26  | s26-nomad
 10.30.51.36  | s17-t33-sut1
 10.30.51.37  | s18-t33-sut2
 10.30.51.38  | fdio-marvell-dev
@@ -400,23 +418,27 @@ Name         | Comment
 10.30.51.71  | s56-t14-sut1
 10.30.51.72  | s62-t34-sut1
 10.30.51.73  | s63-t34-sut2
-10.30.51.74  | s64-t34t36-tg1
+10.30.51.74  | s64-t34-tg1
 10.30.51.75  | s65-t37-sut1
 10.30.51.76  | s66-t37-sut2
 10.30.51.77  | s67-t37-tg1
-10.30.51.78  | s68-t38-sut1
-10.30.51.79  | s69-t38-sut2
-10.30.51.80  | s70-t38-tg1
+10.30.51.78  | s78-t38-sut1
+10.30.51.79  | s79-t38-sut2
+10.30.51.80  | s80-t38-tg1
 10.30.51.81  | s71-t212-sut1
 10.30.51.82  | s72-t212-tg1
-10.30.51.83  | s73-t213-sut1
-10.30.51.84  | s74-t213-tg1
-10.30.51.85  | s75-t214-sut1
-10.30.51.86  | s76-t214-tg1
-10.30.51.87  | s77-t215-sut1
-10.30.51.88  | s78-t215-tg1
-10.30.51.89  | s79-t39t310-tg1
-10.30.51.90  | s80-t311t312-tg1
+10.30.51.83  | s83-t213-sut1
+10.30.51.84  | s84-t213-tg1
+10.30.51.85  | s85-t214-sut1
+10.30.51.86  | s86-t214-tg1
+10.30.51.87  | s87-t215-sut1
+10.30.51.88  | s88-t215-tg1
+10.30.51.89  | s89-t39t310-tg1
+10.30.51.90  | s90-t311t312-tg1
+10.30.51.91  | s58-nomad
+10.30.51.92  | s59-nomad
+10.30.51.93  | s93-t39-sut1
+10.30.51.94  | s94-t39-sut2
 10.30.51.255 | Broadcast
 10.32.8.0    | network
 10.32.8.1    | Router
@@ -424,10 +446,6 @@ Name         | Comment
 10.32.8.11   | s29-t26-sut1
 10.32.8.12   | s30-t35-sut1
 10.32.8.13   | s31-t35-sut2
-10.32.8.14   | s46-nomad
-10.32.8.15   | s47-nomad
-10.32.8.16   | s48-nomad
-10.32.8.17   | s57-nomad
 10.32.8.18   | s33-t27-sut1
 10.32.8.19   | s34-t27-tg1
 10.32.8.20   | s35-t28-sut1
@@ -663,7 +681,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
+            - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
@@ -683,13 +701,13 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
+            - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
+            - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
             - PCIe Slot10 d8:00.xx: empty.
 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
     - Quantity: 3.
     - Physical connectivity:
-        - CIMC and host management ports.
+        - IPMI and host management ports.
         - no NIC ports, standalone setup.
     - Main HW configuration:
         - Chassis: SuperMicro 1029P-WTRT.
@@ -776,28 +794,38 @@ FD.io CSIT lab contains following server types:
         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
     - NICs configuration:
         - Numa0:
-            - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
+            - no cards
         - Numa1:
             - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
 20.  Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
-    - Quantity: 1
+    - Quantity: 2
     - Physical connectivity:
         - IPMI and host management ports.
         - NIC ports connected into 3-node topologies.
     - Main HW configuration:
-        - Chassis: TBD
-        - Motherboard: TBD
-        - Processors: n* TBD
-        - RAM Memory: n* TBD
-        - Disks: TBD
+        - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
+        - Motherboard: Mt.Jade Motherboard
+        - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
+        - RAM Memory: 16* 8GB DDR4-3200MT/s
+        - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
     - NICs configuration:
         - Numa0:
-            - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
-            - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
+            - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
         - Numa1:
-            - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
-            - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-21.  Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
+            - no cards.
+21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
+    - Quantity: 2.
+    - Physical connectivity:
+        - IPMI and host management ports.
+    - Main HW configuration:
+        - Chassis: Gigabyte R152-P30-00 1U
+        - Motherboard: MP32-AR1-00
+        - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
+        - RAM Memory: 12* 16GB DDR4-3200MT/s
+        - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
+22.  Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
     - Quantity: 1
     - Physical connectivity:
         - IPMI and host management ports.
@@ -817,7 +845,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-22. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
+23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
     - Quantity: 8.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -837,7 +865,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-23. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
+24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
     - Quantity: 3.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -857,7 +885,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-24. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
+25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
     - Quantity: 3.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -877,7 +905,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-25. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
     - Quantity: 3.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -897,6 +925,20 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
             - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
             - PCIe Slot10 d8:00.xx: empty.
+27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
+    - Quantity: 2
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 3-node testbed topology.
+    - Main HW configuration:
+        - Chassis: Intel JACOBSVILLE SDP.
+        - Motherboard: Intel JACOBSVILLE E63448-400.
+        - Processors: 1* Intel Atom P5362B 2.2 GHz.
+        - RAM Memory: 2* 16GB DDR4-2933.
+        - Disks: ?* ? SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, PCIe3.0 lane)
+            - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
 ```
 
 ### Naming Convention
@@ -1217,8 +1259,10 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
-        - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
+        - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+        - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
 - SUT [Server-Type-C2]:
@@ -1249,8 +1293,10 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
-        - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
+        - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+        - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
 - SUT [Server-Type-C2]:
@@ -1281,8 +1327,8 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
-        - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
+        - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
         - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
         - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
 ```
@@ -1331,8 +1377,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
     - IPMI IP: 10.30.50.69
     - Host IP: 10.30.51.69
     - portnames:
-        - s27-t211-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s27-t211-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
         - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
         - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
 - TG [Server-Type-E31]:
@@ -1355,7 +1399,7 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
 ```
 
-#### 2-Node-Icelake Servers (2n-icx) TBD
+#### 2-Node-Icelake Servers (2n-icx) PROD
 
 ```
 - SUT [Server-Type-F1]:
@@ -1390,94 +1434,94 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
         - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 - SUT [Server-Type-F1]:
     - testbedname: testbed213.
-    - hostname: s73-t213-sut1.
+    - hostname: s83-t213-sut1.
     - IPMI IP: 10.30.51.83
     - Host IP: 10.30.50.83
     - portnames:
-        - s73-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s73-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s73-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s73-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s73-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s73-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s73-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s73-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 - TG [Server-Type-F2]:
     - testbedname: testbed213.
-    - hostname: s74-t213-tg1.
+    - hostname: s84-t213-tg1.
     - IPMI IP: 10.30.51.84
     - Host IP: 10.30.50.84
     - portnames:
-        - s74-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s74-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s74-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s74-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s74-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s74-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s74-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s74-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-        - s74-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s74-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 - SUT [Server-Type-F1]:
     - testbedname: testbed214.
-    - hostname: s75-t214-sut1.
+    - hostname: s85-t214-sut1.
     - IPMI IP: 10.30.51.85
     - Host IP: 10.30.50.85
     - portnames:
-        - s75-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s75-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s75-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s75-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s75-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s75-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s75-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s75-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 - TG [Server-Type-F2]:
     - testbedname: testbed214.
-    - hostname: s76-t214-tg1.
+    - hostname: s86-t214-tg1.
     - IPMI IP: 10.30.51.86
     - Host IP: 10.30.50.86
     - portnames:
-        - s76-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s76-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s76-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s76-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s76-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s76-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s76-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s76-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-        - s76-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s76-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 - SUT [Server-Type-F1]:
     - testbedname: testbed215.
-    - hostname: s77-t215-sut1.
+    - hostname: s87-t215-sut1.
     - IPMI IP: 10.30.51.87
     - Host IP: 10.30.50.87
     - portnames:
-        - s77-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s77-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s77-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s77-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s77-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s77-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s77-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s77-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 - TG [Server-Type-F2]:
     - testbedname: testbed215.
-    - hostname: s78-t215-tg1.
+    - hostname: s88-t215-tg1.
     - IPMI IP: 10.30.51.88
     - Host IP: 10.30.50.88
     - portnames:
-        - s78-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s78-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s78-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s78-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s78-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s78-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s78-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s78-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-        - s78-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s78-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 ```
 
 #### 3-Node-Skylake Servers (3n-skx) PROD
@@ -1644,9 +1688,7 @@ Note: Server19 (TG) is shared between testbed33 & testbed211
         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
 ```
 
-#### 3-Node-Altra Servers (3n-alt) TBD
-
-Note: Server64 (TG) is shared between testbed34 & testbed36
+#### 3-Node-Altra Servers (3n-alt) PROD
 
 ```
 - SUT [Server-Type-E23]:
@@ -1655,28 +1697,32 @@ Note: Server64 (TG) is shared between testbed34 & testbed36
     - IPMI IP: 10.30.50.72
     - Host IP: 10.30.51.72
     - portnames:
-        - s62-t34-sut1-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
-        - s62-t34-sut1-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
-        - s62-t34-sut1-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s62-t34-sut1-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
+        - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
 - SUT [Server-Type-E23]:
     - testbedname: testbed34.
     - hostname: s63-t34-sut2.
     - IPMI IP: 10.30.50.73
     - Host IP: 10.30.51.73
     - portnames:
-        - s63-t34-sut2-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
-        - s63-t34-sut2-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
-        - s63-t34-sut2-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s63-t34-sut2-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
+        - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
 - TG [Server-Type-F4]:
     - testbedname: testbed34.
-    - hostname: s64-t34t36-tg1.
+    - hostname: s64-t34-tg1.
     - IPMI IP: 10.30.50.74
     - Host IP: 10.30.51.74
     - portnames:
-        - s64-t34-tg1-c1/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s64-t34-tg1-c1/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+        - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 ```
 
 #### 3-Node-Denverton Servers (3n-dnv) PROD
@@ -1704,7 +1750,7 @@ Note: Server64 (TG) is shared between testbed34 & testbed36
         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
 ```
 
-#### 3-Node-Icelake Servers (3n-icx) TBD
+#### 3-Node-Icelake Servers (3n-icx) PROD
 
 ```
 - ServerF1 [Server-Type-F1]:
@@ -1751,46 +1797,81 @@ Note: Server64 (TG) is shared between testbed34 & testbed36
         - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 - ServerF1 [Server-Type-F1]:
     - testbedname: testbed38.
-    - hostname: s68-t38-sut1.
+    - hostname: s78-t38-sut1.
     - IPMI IP: 10.30.50.78
     - Host IP: 10.30.51.78
     - portnames:
-        - s68-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s68-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s68-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s68-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s68-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s68-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s68-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s68-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 - ServerF1 [Server-Type-F1]:
     - testbedname: testbed38.
-    - hostname: s69-t38-sut2.
+    - hostname: s79-t38-sut2.
     - IPMI IP: 10.30.50.79
     - Host IP: 10.30.51.79
     - portnames:
-        - s69-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s69-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s69-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s69-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s69-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s69-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s69-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s69-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 - ServerF3 [Server-Type-F3]:
     - testbedname: testbed38.
-    - hostname: s70-t38-tg1.
+    - hostname: s80-t38-tg1.
     - IPMI IP: 10.30.50.80
     - Host IP: 10.30.51.80
     - portnames:
-        - s70-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s70-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s70-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s70-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s70-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s70-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s70-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s70-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+```
+
+#### 3-Node-SnowRidge Servers (3n-snr) PROD
+
+```
+- ServerG1 [Server-Type-G1]:
+    - testbedname: testbed39.
+    - hostname: s93-t39-sut1.
+    - IPMI IP: 10.30.50.93
+    - Host IP: 10.30.51.93
+    - portnames:
+        - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerG1 [Server-Type-G1]:
+    - testbedname: testbed39.
+    - hostname: s94-t39-sut2.
+    - IPMI IP: 10.30.50.94
+    - Host IP: 10.30.51.94
+    - portnames:
+        - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerF4 [Server-Type-F4]:
+    - testbedname: testbed39.
+    - hostname: s89-t39t310-tg1.
+    - IPMI IP: 10.30.50.89
+    - Host IP: 10.30.51.89
+    - portnames:
+        - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
 ```
 
 ### Per Testbed Wiring
@@ -1949,9 +2030,12 @@ Note: Server64 (TG) is shared between testbed34 & testbed36
     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
-    - ring5 100GE-ports e810-2p100GE on SUT:
+    - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
         - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
         - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
+    - ring6 100GE-ports e810-2p100GE on TG:
+        - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
+        - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
 - testbed28:
     - ring1 10GE-ports x710-4p10GE on SUT:
         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
@@ -1965,9 +2049,12 @@ Note: Server64 (TG) is shared between testbed34 & testbed36
     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
-    - ring5 100GE-ports e810-2p100GE on SUT:
+    - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
         - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
         - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
+    - ring6 100GE-ports e810-2p100GE on TG:
+        - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
+        - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
 - testbed29:
     - ring1 10GE-ports x710-4p10GE on SUT:
         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
@@ -1981,7 +2068,7 @@ Note: Server64 (TG) is shared between testbed34 & testbed36
     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
-    - ring6 100GE-ports e810-2p100GE on SUT:
+    - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
         - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
         - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
 ```
@@ -2013,7 +2100,7 @@ Note: Server64 (TG) is shared between testbed34 & testbed36
         - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
 ```
 
-#### 2-Node-Icelake Wiring (2n-icx) TBD
+#### 2-Node-Icelake Wiring (2n-icx) PROD
 
 ```
 - testbed212:
@@ -2033,49 +2120,49 @@ Note: Server64 (TG) is shared between testbed34 & testbed36
         - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
 - testbed213:
     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s74-t213-tg1-c2/p1 to s73-t213-sut1-c2/p1.
-        - s73-t213-sut1-c2/p2 to s74-t213-tg1-c2/p2.
+        - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
+        - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
-        - s74-t213-tg1-c4/p1 to s73-t213-sut1-c4/p1.
-        - s73-t213-sut1-c4/p2 to s74-t213-tg1-c4/p2.
-        - s74-t213-tg1-c4/p3 to s73-t213-sut1-c4/p3.
-        - s73-t213-sut1-c4/p4 to s74-t213-tg1-c4/p4.
+        - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
+        - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
+        - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
+        - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
-        - s74-t213-tg1-c9/p1 to s73-t213-sut1-c9/p1.
-        - s73-t213-sut1-c9/p2 to s74-t213-tg1-c9/p2.
+        - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
+        - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
-        - s74-t213-tg1-c6/p1 to s74-t213-tg1-c6/p2.
-        - s74-t213-tg1-c6/p2 to s74-t213-tg1-c6/p1.
+        - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
+        - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
 - testbed214:
     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s76-t214-tg1-c2/p1 to s75-t214-sut1-c2/p1.
-        - s75-t214-sut1-c2/p2 to s76-t214-tg1-c2/p2.
+        - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
+        - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
-        - s76-t214-tg1-c4/p1 to s75-t214-sut1-c4/p1.
-        - s75-t214-sut1-c4/p2 to s76-t214-tg1-c4/p2.
-        - s76-t214-tg1-c4/p3 to s75-t214-sut1-c4/p3.
-        - s75-t214-sut1-c4/p4 to s76-t214-tg1-c4/p4.
+        - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
+        - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
+        - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
+        - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
-        - s76-t214-tg1-c9/p1 to s75-t214-sut1-c9/p1.
-        - s75-t214-sut1-c9/p2 to s76-t214-tg1-c9/p2.
+        - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
+        - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
-        - s76-t214-tg1-c6/p1 to s76-t214-tg1-c6/p2.
-        - s76-t214-tg1-c6/p2 to s76-t214-tg1-c6/p1.
+        - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
+        - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
 - testbed215:
     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s78-t215-tg1-c2/p1 to s77-t215-sut1-c2/p1.
-        - s77-t215-sut1-c2/p2 to s78-t215-tg1-c2/p2.
+        - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
+        - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
-        - s78-t215-tg1-c4/p1 to s77-t215-sut1-c4/p1.
-        - s77-t215-sut1-c4/p2 to s78-t215-tg1-c4/p2.
-        - s78-t215-tg1-c4/p3 to s77-t215-sut1-c4/p3.
-        - s77-t215-sut1-c4/p4 to s78-t215-tg1-c4/p4.
+        - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
+        - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
+        - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
+        - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
-        - s78-t215-tg1-c9/p1 to s77-t215-sut1-c9/p1.
-        - s77-t215-sut1-c9/p2 to s78-t215-tg1-c9/p2.
+        - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
+        - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
-        - s78-t215-tg1-c6/p1 to s78-t215-tg1-c6/p2.
-        - s78-t215-tg1-c6/p2 to s78-t215-tg1-c6/p1.
+        - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
+        - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
 ```
 
 #### 3-Node-Skylake Wiring (3n-skx) PROD
@@ -2123,7 +2210,7 @@ Note: Server64 (TG) is shared between testbed34 & testbed36
         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
 ```
 
-#### 3-Node-Rangeley Wiring (3n-rng) TODO
+#### 3-Node-Rangeley Wiring (3n-rng) VERIFY
 
 ```
 To be completed.
@@ -2143,18 +2230,14 @@ To be completed.
         - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
 ```
 
-#### 3-Node-Altra Wiring (3n-alt) TBD
+#### 3-Node-Altra Wiring (3n-alt) PROD
 
 ```
 - testbed34:
     - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
-        - s64-t34-tg1-cn/p2 - s62-t34-sut1-cn/p2.
-        - s62-t34-sut1-cn/p1 - s63-t34-sut2-cn/p2.
-        - s63-t34-sut2-cn/p1 - s64-t34-tg1-cn/p1.
-    - ring2 100GE-ports ConnectX5-2p100GE on SUTs:
-        - s64-t34-tg1-ck/p2 - s62-t34-sut1-ck/p2.
-        - s62-t34-sut1-ck/p1 - s63-t34-sut2-ckp2.
-        - s63-t34-sut2-ck/p1 - s64-t34-tg1-ck/p1.
+        - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
+        - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
+        - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
 ```
 
 #### 3-Node-Denverton Wiring (3n-dnv) PROD
@@ -2171,7 +2254,7 @@ To be completed.
         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
 ```
 
-#### 3-Node-Icelake Wiring (3n-icx) TBD
+#### 3-Node-Icelake Wiring (3n-icx) PROD
 
 ```
 - testbed37:
@@ -2192,20 +2275,33 @@ To be completed.
         - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
 - testbed38:
     - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
-        - s70-t38-tg1-c2/p1 to s68-t38-sut1-c2/p1.
-        - s68-t38-sut1-c2/p2 to s69-t38-sut2-c2/p2.
-        - s69-t38-sut2-c2/p1 to s70-t38-tg1-c2/p2.
+        - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
+        - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
+        - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
     - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
-        - s70-t38-tg1-c4/p1 to s68-t38-sut1-c4/p1.
-        - s68-t38-sut1-c4/p2 to s69-t38-sut2-c4/p2.
-        - s69-t38-sut2-c4/p1 to s70-t38-tg1-c4/p2.
-        - s70-t38-tg1-c4/p3 to s68-t38-sut1-c4/p3.
-        - s68-t38-sut1-c4/p4 to s69-t38-sut2-c4/p4.
-        - s69-t38-sut2-c4/p3 to s70-t38-tg1-c4/p4.
+        - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
+        - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
+        - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
+        - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
+        - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
+        - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
-        - s70-t38-tg1-c9/p1 to s68-t38-sut1-c9/p1.
-        - s68-t38-sut1-c9/p2 to s69-t38-sut2-c9/p2.
-        - s69-t38-sut2-c9/p1 to s70-t38-tg1-c9/p2.
+        - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
+        - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
+        - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
+```
+
+#### 3-Node-SnowRidge Wiring (3n-snr) PROD
+
+```
+- testbed39:
+    - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
+        - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
+        - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
+        - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
+        - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
+        - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
+        - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
 ```
 
 ## Inventory
@@ -2244,11 +2340,20 @@ To be completed.
         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
         - RAM Memory: 8* 16GB DDR4-2400MT/s.
         - Disks: 1* 4TB SATA HDD.
-    - 2 * Ampere Altra
-        - Chassis: TBD
-        - Processors: TBD
-        - RAM Memory: TBD
-        - Disks: TBD
+2. Arm Neoverse N1 servers
+    - 2 * Ampere Altra (Performance)
+        - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
+        - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
+        - RAM Memory: 16* 8GB DDR4-3200MT/s
+        - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
+    - 2 * Ampere Altra (Build)
+        - Chassis: Gigabyte R152-P30-00 1U
+        - Motherboard: MP32-AR1-00
+        - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
+        - RAM Memory: 12* 16GB DDR4-3200MT/s
+        - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
 ```
 
 ### Xeon and Atom Servers
@@ -2273,15 +2378,13 @@ To be completed.
 
 ```
 1. 10GE NICs
-    - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
-    - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
-    - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
+    - ?
 2. 25GE NICs
-    - 12 * Intel® Ethernet Network Adapter XXV710-DA2
+    - ?
 3. 40GE NICs
-    - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
+    - ?
 4. 100GE NICs
-    - 4 * mcx556a-edat NICs (not on site yet, in transit)
+    - ?
 ```
 
 ### Pluggables and Cables
@@ -2290,27 +2393,26 @@ Pluggables:
 
 ```
 1. 10GE SFP+
-    - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
-    - 80 * 10G SR optic (generic, "Intel" compatible branded)
+    - ?
 2. 25GE SFP28
-    - None
+    - ?
 3. 40GE QSFP+
-    - None
+    - ?
 4. 100GE
-    - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
+    - ?
 ```
 
 Standalone cables:
 
 ```
 1. 10GE
-    - None
+    - ?
 2. 25GE
-    - None
+    - ?
 3. 40GE QSFP+
-    - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
+    - ?
 4. 100GE
-    - None
+    - ?
 ```
 
 ### Other Parts