feat(pxe): Migrate Ubuntu Jammy I.
[csit.git] / docs / lab / testbed_specifications.md
index 73138ec..fad1bdc 100644 (file)
@@ -1,48 +1,67 @@
 # FD.io CSIT Testbed Specifications
 
-1. [FD.io CSIT Testbed Specifications](#fdio-csit-testbed-specifications)
+1. [Purpose](#purpose)
 1. [Testbeds Overview](#testbeds-overview)
    1. [Summary List](#summary-list)
    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
+   1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
-   1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
+   1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
+   1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
+   1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
+   1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
-   1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
-   1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
+   1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
+   1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
+   1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
+   1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
 1. [Server Management](#server-management)
    1. [Requirements](#requirements)
    1. [Addressing](#addressing)
    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
-1. [Server Type Specification](#server-type-specification)
-   1. [Server and Port Naming](#server-and-port-naming)
+1. [Server Specifications](#server-specifications)
+   1. [Server Types](#server-types)
+   1. [Naming Convention](#naming-convention)
 1. [Testbeds Configuration](#testbeds-configuration)
    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
-      1 [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
-      1 [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
-      1 [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
-      1 [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
-      1 [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
-      1 [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
-      1 [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
-      1 [3-Node-Rangeley (3n-rng) VERIFY](#3-node-rangeley-3n-rng-verify)
-      1 [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip)
-      1 [3-Node-Mcbin (3n-mcb) TODO](#3-node-mcbin-3n-mcb-todo)
+      1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
+      1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
+      1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
+      1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
+      1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
+      1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
+      1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
+      1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
+      1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
+      1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
+      1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
+      1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
+      1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
+      1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
+      1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
+      1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
    1. [Per Testbed Wiring](#per-testbed-wiring)
-      1 [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod)
-      1 [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip)
-      1 [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod)
-      1 [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo)
-      1 [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify)
-      1 [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod)
-      1 [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod)
-      1 [3-Node-Rangeley (3n-rng) TODO](#3-node-rangeley-3n-rng-todo)
-      1 [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip)
-      1 [3-Node-Mcbin (3n-mcb) WIP](#3-node-mcbin-3n-mcb-wip)
+      1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
+      1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
+      1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
+      1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
+      1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
+      1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
+      1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
+      1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
+      1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
+      1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
+      1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
+      1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
+      1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
+      1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
+      1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
+      1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
 1. [Inventory](#inventory)
    1. [Appliances](#appliances)
    1. [Arm Servers](#arm-servers)
@@ -51,7 +70,7 @@
    1. [Pluggables and Cables](#pluggables-and-cables)
    1. [Other Parts](#other-parts)
 
-## FD.io CSIT Testbed Specifications
+## Purpose
 
 This note includes specification of the physical testbed infrastructure
 hosted by LFN FD.io CSIT project.
@@ -61,77 +80,146 @@ hosted by LFN FD.io CSIT project.
 ### Summary List
 
 ```
- #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
- 1. 1-Node-Skylake     func   skx   na    2    2    0    0    2    0    0    0    0    0    0
- 2. 1-Node-Thunderx2   func   tx2   na    1    1    0    0    0    0    0    0    1    0    0
- 3. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0
- 4. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0
- 5. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0
- 6. 3-Node-Haswell     perf   hsw   hsw   3    6    3    9    0    0    0    0    0    0    0
- 7. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0
- 8. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0
- 9. 3-Node-Taishan     perf   tsh   skx   1    2    1    0    .5   0    0    0    0    2    0
-10. 3-Node-Mcbin       perf   mcb   skx   1    2    1    0    .5   0    0    0    0    0    2
-11. 1-Node-VIRL        func   hsw   ---   3    3    0    3    0    0    0    0    0    0    0
-                                 Totals: 17   26   14   12   19    1    2    1    1    2    2
+ #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx #snr
+ 1. 1-Node-Haswell     nomad  hsw   na    4    4    0    4    0    0    0    0    0    0    0    0    0    0    0
+ 2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0    0    0    0
+ 3. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0    0    0    0
+ 4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0    1    0    0    0
+ 5. 1-Node-AmpereAltra nomad  alt   na    2    2    0    0    0    0    0    0    0    0    2    0    0    0    0
+ 6. 2-Node-Skylake     perf   skx   skx   3    3    3    0    6    0    0    0    0    0    0    0    0    0    0
+ 7. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0    0    0    0
+ 8. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0    0    0    0
+ 9. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0    6    0    0    0
+10. 2-Node-ThunderX2   perf   tx2   skx   1    1    .5   0    .5   0    0    0    1    0    0    0    0    0    0
+11. 2-Node-Icelake     perf   icx   icx   4    4    4    0    0    0    0    0    0    0    0    0    0    8    0
+12. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0    0    0    0
+13. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0    0    0    0
+14. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0    0    0    0
+15. 3-Node-Altra       perf   alt   icx   1    2    1    0    0    0    0    0    0    0    2    0    0    1    0
+16. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0    0    0    0
+17. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    0    2    0    0
+18. 3-Node-Icelake     perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    0    0    6    0
+19. 3-Node-SnowRidge   perf   snr   icx   1    2    .5   0    0    0    0    0    0    0    0    0    0    .5   2
+                                 Totals: 34   44  21.5   4   17    1    2    3    3    2    4    7    2  15.5   2
 ```
 
 ### 1-Node-Skylake Xeon Intel (1n-skx)
 
-Each 1-Node-Skylake testbed includes one SUT (Type-B6 server) with NIC
-ports connected back-to-back.
+Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
+ports connected back-to-back ([Server Types](#server-types)).
 Used for FD.io VPP_Device functional driver tests.
 
 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
 
-Each 1-Node-ThunderX2 testbed includes one SUT (Type-B9 server) with NIC
-ports connected back-to-back.
+Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
+ports connected back-to-back ([Server Types](#server-types)).
+Used for FD.io VPP_Device functional driver tests.
+
+### 1-Node-Cascadelake Xeon Intel (1n-clx)
+
+Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
+NIC ports connected back-to-back ([Server Types](#server-types)).
+
 Used for FD.io VPP_Device functional driver tests.
 
 ### 2-Node-Skylake Xeon Intel (2n-skx)
 
-Each 2-Node-Skylake testbed includes one SUT (Type-B1 server) and one TG
-(Type-B2 server) connected back-to-back.
+Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
+(Server-Type-B2) connected in a 2-node circular topology
+([Server Types](#server-types)).
 Used for FD.io performance tests.
 
 ### 2-Node-Denverton Atom Intel (2n-dnv)
 
-Each 2-Node-Skylake testbed includes one SUT (Type-B10 server) and one TG
-(Type-B2 server) connected back-to-back.
+Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
+TG (Server-Type-B2) connected in a 2-node circular topology
+([Server Types](#server-types)).
 Used for FD.io performance tests.
 
 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
 
-Each 2-Node-IxiaPS1L47 testbed includes one SUT (Type-B1 server) and one
-TG (Ixia PSOne appliance) with 10GE interfaces connected back-to-back.
+Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
+TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
+circular topology ([Server Types](#server-types)).
 Used for FD.io TCP/IP and HTTP performance tests.
 
-### 3-Node-Haswell Xeon Intel (3n-skx)
+### 2-Node-Cascadelake Xeon Intel (2n-clx)
+
+Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
+one TG (Server-Type-C3) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 2-Node-Zen2 EPYC AMD (2n-zn2)
+
+Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
+one TG (Server-Type-D2) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
+
+Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
+one TG (Server-Type-E31) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 2-Node-Icelake Xeon Intel (2n-icx)
+
+Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
+one TG (Server-Type-F2) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 3-Node-Haswell Xeon Intel (3n-hsw)
+
+Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
+TG (Server-Type-A2) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
 
 ### 3-Node-Skylake Xeon Intel (3n-skx)
 
-Each 3-Node-Skylake testbed includes two SUTs (Type-B1 servers) and one
-TG (Type-B2 server) connected in full-mesh triangle.
+Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
+TG (Server-Type-B2) connected in a 3-node circular topology.
+Used for FD.io performance tests.
+
+### 3-Node-Rangeley Atom Testbeds
+
+Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
+TG (Server-Type-2) connected in a 3-node circular topology
+([Server Types](#server-types)).
 Used for FD.io performance tests.
 
 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
 
-Each 3-Node-TaiShan testbed includes two SUTs (Type-B3 server) and one TG
-(Type-B2 server) connected in full-mesh triangle.
+Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
+TG (Server-Type-E31) connected in a 3-node circular topology
+([Server Types](#server-types)).
 Used for FD.io performance tests.
 
-### 3-Node-MACCHIATObin Arm Marvell
+### 3-Node-Altra Arm Ampere (3n-alt)
 
-Each 3-Node-MACCHIATObin testbed includes two SUTs (Type-B4 server) and
-one TG (Type-B2 server) connected in full-mesh triangle.
+Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
+TG (Server-Type-F4) connected in a 3-node circular topology
+([Server Types](#server-types)).
 Used for FD.io performance tests.
 
-### 3-Node-Rangeley Atom Testbeds
+### 3-Node-Icelake Xeon Intel (3n-icx)
+
+Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
+TG (Server-Type-F3) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 3-Node-SnowRidge Atom Intel (3n-snr)
 
-Each 3-Node-Rangeley testbed includes two SUTs (Type-B5 Netgate device)
-and one TG (Type-2 server) connected in full-mesh triangle.
+Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
+TG (Server-Type-F4) connected in a 3-node circular topology
+([Server Types](#server-types)).
 Used for FD.io performance tests.
 
+
 ## Server Management
 
 ### Requirements
@@ -142,16 +230,16 @@ connected to the management network:
 ```
 - 1GE IPMI port
   - IPMI - Intelligent Platform Management Interface.
-  - Required for access to embedded server management with WebUI, CLI, SNMPv3,
-    IPMIv2.0, for firmware (BIOS) and OS updates.
+  - Required for access to embedded server management with WebUI, CLI,
+    SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
 - 1GE/10GE/40GE management port
   - hostOS management port for general system management.
 ```
 
 ### Addressing
 
-Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management
-port, which are connected to two different VLANs.
+Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
+Management port, which are connected to two different VLANs.
 
 ```
 1. LOM (IPMI) VLAN:
@@ -190,26 +278,28 @@ Name         | Comment
 10.30.50.13  | LF Reserved
 10.30.50.14  | LF Reserved
 10.30.50.15  | LF Reserved
-10.30.50.16  | t1-tg1
-10.30.50.17  | t1-sut1
-10.30.50.18  | t1-sut2
-10.30.50.20  | t2-tg1
-10.30.50.21  | t2-sut1
-10.30.50.22  | t2-sut2
-10.30.50.24  | t3-tg1
-10.30.50.25  | t3-sut1
-10.30.50.26  | t3-sut-2
-10.30.50.28  | t4-sut1
-10.30.50.29  | t4-sut2
-10.30.50.30  | t4-sut3
+10.30.50.16  | s16-nomad
+10.30.50.17  | s17-nomad
+10.30.50.18  | s18-nomad
+10.30.50.19  | s19-nomad
+10.30.50.20  | s20-nomad
+10.30.50.21  | s21-nomad
+10.30.50.22  | s22-nomad
+10.30.50.23  | s23-nomad
+10.30.50.24  | s24-nomad
+10.30.50.25  | s25-nomad
+10.30.50.26  | s26-nomad
 10.30.50.36  | s17-t33-sut1
 10.30.50.37  | s18-t33-sut2
+10.30.50.38  | fdio-marvell-dev
+10.30.50.39  | s53-nomad
+10.30.50.40  | s54-nomad
 10.30.50.41  | s3-t21-sut1
 10.30.50.42  | s4-t21-tg1
 10.30.50.43  | s11-t31-sut1
 10.30.50.44  | s12-t31-sut2
 10.30.50.45  | s13-t31-tg1
-10.30.50.46  | s19-t33t34-tg1
+10.30.50.46  | s19-t33t211-tg1
 10.30.50.47  | s1-t11-sut1
 10.30.50.48  | s2-t12-sut1
 10.30.50.49  | s5-t22-sut1
@@ -223,78 +313,156 @@ Name         | Comment
 10.30.50.57  | s16-t32-tg1
 10.30.50.58  | s25-t25-sut1
 10.30.50.59  | s26-t25-tg1
-10.30.50.69  | s27-t13-sut
+10.30.50.65  | s52-nomad
+10.30.50.66  | s51-nomad
+10.30.50.67  | s49-nomad
+10.30.50.68  | s50-nomad
+10.30.50.69  | s27-t211-sut1
+10.30.50.70  | s55-t13-sut1
+10.30.50.71  | s56-t14-sut1
+10.30.50.72  | s62-t34-sut1
+10.30.50.73  | s63-t34-sut2
+10.30.50.74  | s64-t34-tg1
+10.30.50.75  | s65-t37-sut1
+10.30.50.76  | s66-t37-sut2
+10.30.50.77  | s67-t37-tg1
+10.30.50.78  | s78-t38-sut1
+10.30.50.79  | s79-t38-sut2
+10.30.50.80  | s80-t38-tg1
+10.30.50.81  | s71-t212-sut1
+10.30.50.82  | s72-t212-tg1
+10.30.50.83  | s83-t213-sut1
+10.30.50.84  | s84-t213-tg1
+10.30.50.85  | s85-t214-sut1
+10.30.50.86  | s86-t214-tg1
+10.30.50.87  | s87-t215-sut1
+10.30.50.88  | s88-t215-tg1
+10.30.50.89  | s89-t39t310-tg1
+10.30.50.90  | s90-t311t312-tg1
+10.30.50.91  | s58-nomad
+10.30.50.92  | s59-nomad
+10.30.50.93  | s93-t39-sut1
+10.30.50.94  | s94-t39-sut2
 10.30.50.255 | Broadcast
+10.30.55.0   | network
+10.30.55.1   | Router
+10.30.55.10  | s28-t26t35-tg1
+10.30.55.11  | s29-t26-sut1
+10.30.55.12  | s30-t35-sut1
+10.30.55.13  | s31-t35-sut2
+10.30.55.18  | s33-t27-sut1
+10.30.55.19  | s34-t27-tg1
+10.30.55.20  | s35-t28-sut1
+10.30.55.21  | s36-t28-tg1
+10.30.55.22  | s37-t29-sut1
+10.30.55.23  | s38-t29-tg1
+10.30.55.24  | s60-t210-sut1
+10.30.55.25  | s61-t210-tg1
+10.30.55.255 | Broadcast
 
 ### Management VLAN IP Addresses
 
-Name                      | Comment
-------------------------- | -------
-10.30.51.0                | network
-10.30.51.1                | Router
-10.30.51.2                | LF Reserved
-10.30.51.3                | LF Reserved
-10.30.51.4                | LF Reserved
-10.30.51.5                | LF Reserved
-10.30.51.6                | LF Reserved
-10.30.51.7                | LF Reserved
-10.30.51.8                | LF Reserved
-10.30.51.9                | s22-t35-sut1 (netgate-1)
-10.30.51.10               | s23-t35-sut2 (netgate-2)
-10.30.51.11               | s24-t35-sut3 (netgate-3)
-10.30.51.12               | softiron-1
-10.30.51.13               | softiron-2
-10.30.51.14               | softiron-3
-10.30.51.15               | LF Reserved
-10.30.51.16               | t1-tg1
-10.30.51.17               | t1-sut1
-10.30.51.18               | t1-sut2
-10.30.51.20               | t2-tg1
-10.30.51.21               | t2-sut1
-10.30.51.22               | t2-sut2
-10.30.51.24               | t3-tg1
-10.30.51.25               | t3-sut1
-10.30.51.26               | t3-sut-2
-10.30.51.28               | t4-sut1
-10.30.51.29               | t4-sut2
-10.30.51.29               | s22-t35-sut1 screen -r /dev/ttyUSB0, TO BE VERIFIED
-10.30.51.30               | t4-sut3
-10.30.51.30               | s23-t35-sut2 screen -r /dev/ttyUSB1, TO BE VERIFIED
-10.30.51.30               | s24-t35-sut3 screen -r /dev/ttyUSB2, TO BE VERIFIED
-10.30.51.36               | s17-t33-sut1
-10.30.51.37               | s18-t33-sut2
-10.30.51.41               | s20-t34-sut1
-10.30.51.42               | s21-t34-sut2
-10.30.51.44               | s3-t21-sut1
-10.30.51.45               | s4-t21-tg1
-10.30.51.46               | s11-t31-sut1
-10.30.51.47               | s12-t31-sut2
-10.30.51.48               | s13-t31-tg1
-10.30.51.49               | s19-t33t34-tg1
-10.30.51.50               | s1-t11-sut1
-10.30.51.51               | s2-t12-sut1
-10.30.51.52               | s5-t22-sut1
-10.30.51.53               | s6-t22-tg1
-10.30.51.54               | s7-t23-sut1
-10.30.51.55               | s8-t23-tg1
-10.30.51.56               | s9-t24-sut1
-10.30.51.57               | s10-t24-tg1
-10.30.51.58               | s14-t32-sut1
-10.30.51.59               | s15-t32-sut2
-10.30.51.60               | s16-t32-tg1
-10.30.51.61               | s25-t25-sut1
-10.30.51.62               | s26-t25-tg1
-10.30.51.69               | s27-t13-sut1
-10.30.51.70-10.30.51.105  | VIRL1 TO BE VERIFIED
-10.30.51.106-10.30.51.180 | VIRL2
-10.30.51.181-10.30.51.254 | VIRL3
-10.30.51.255              | Broadcast
-
-## Server Type Specification
+Name         | Comment
+-------------| -------
+10.30.51.0   | network
+10.30.51.1   | Router
+10.30.51.2   | LF Reserved
+10.30.51.3   | LF Reserved
+10.30.51.4   | LF Reserved
+10.30.51.5   | LF Reserved
+10.30.51.6   | LF Reserved
+10.30.51.7   | LF Reserved
+10.30.51.8   | LF Reserved
+10.30.51.15  | LF Reserved
+10.30.51.16  | s16-nomad
+10.30.51.17  | s17-nomad
+10.30.51.18  | s18-nomad
+10.30.51.19  | s19-nomad
+10.30.51.20  | s20-nomad
+10.30.51.21  | s21-nomad
+10.30.51.22  | s22-nomad
+10.30.51.23  | s23-nomad
+10.30.51.24  | s24-nomad
+10.30.51.25  | s25-nomad
+10.30.51.26  | s26-nomad
+10.30.51.36  | s17-t33-sut1
+10.30.51.37  | s18-t33-sut2
+10.30.51.38  | fdio-marvell-dev
+10.30.51.39  | s53-nomad
+10.30.51.40  | s54-nomad
+10.30.51.44  | s3-t21-sut1
+10.30.51.45  | s4-t21-tg1
+10.30.51.46  | s11-t31-sut1
+10.30.51.47  | s12-t31-sut2
+10.30.51.48  | s13-t31-tg1
+10.30.51.49  | s19-t33t211-tg1
+10.30.51.50  | s1-t11-sut1
+10.30.51.51  | s2-t12-sut1
+10.30.51.52  | s5-t22-sut1
+10.30.51.53  | s6-t22-tg1
+10.30.51.54  | s7-t23-sut1
+10.30.51.55  | s8-t23-tg1
+10.30.51.56  | s9-t24-sut1
+10.30.51.57  | s10-t24-tg1
+10.30.51.58  | s14-t32-sut1
+10.30.51.59  | s15-t32-sut2
+10.30.51.60  | s16-t32-tg1
+10.30.51.61  | s25-t25-sut1
+10.30.51.62  | s26-t25-tg1
+10.30.51.65  | s52-nomad
+10.30.51.66  | s51-nomad
+10.30.51.67  | s49-nomad
+10.30.51.68  | s50-nomad
+10.30.51.69  | s27-t211-sut1
+10.30.51.70  | s55-t13-sut1
+10.30.51.71  | s56-t14-sut1
+10.30.51.72  | s62-t34-sut1
+10.30.51.73  | s63-t34-sut2
+10.30.51.74  | s64-t34-tg1
+10.30.51.75  | s65-t37-sut1
+10.30.51.76  | s66-t37-sut2
+10.30.51.77  | s67-t37-tg1
+10.30.51.78  | s78-t38-sut1
+10.30.51.79  | s79-t38-sut2
+10.30.51.80  | s80-t38-tg1
+10.30.51.81  | s71-t212-sut1
+10.30.51.82  | s72-t212-tg1
+10.30.51.83  | s83-t213-sut1
+10.30.51.84  | s84-t213-tg1
+10.30.51.85  | s85-t214-sut1
+10.30.51.86  | s86-t214-tg1
+10.30.51.87  | s87-t215-sut1
+10.30.51.88  | s88-t215-tg1
+10.30.51.89  | s89-t39t310-tg1
+10.30.51.90  | s90-t311t312-tg1
+10.30.51.91  | s58-nomad
+10.30.51.92  | s59-nomad
+10.30.51.93  | s93-t39-sut1
+10.30.51.94  | s94-t39-sut2
+10.30.51.255 | Broadcast
+10.32.8.0    | network
+10.32.8.1    | Router
+10.32.8.10   | s28-t26t35-tg1
+10.32.8.11   | s29-t26-sut1
+10.32.8.12   | s30-t35-sut1
+10.32.8.13   | s31-t35-sut2
+10.32.8.18   | s33-t27-sut1
+10.32.8.19   | s34-t27-tg1
+10.32.8.20   | s35-t28-sut1
+10.32.8.21   | s36-t28-tg1
+10.32.8.22   | s37-t29-sut1
+10.32.8.23   | s38-t29-tg1
+10.32.8.24   | s60-t210-sut1
+10.32.8.25   | s61-t210-tg1
+10.32.8.255  | Broadcast
+
+## Server Specifications
+
+### Server Types
 
 FD.io CSIT lab contains following server types:
 ```
-1. Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
+1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
     - Quantity: 6 servers.
     - Physical connectivity:
         - CIMC and host management ports.
@@ -306,15 +474,15 @@ FD.io CSIT lab contains following server types:
         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
     - NICs configuration:
         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
-            - PCIe Slot1: Cisco VIC 1385 2p40GE.
-            - PCIe Slot2: Intel NIC x520 2p10GE.
+            - PCIe Slot1: empty.
+            - PCIe Slot2: empty.
             - PCIe Slot3: empty.
         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
-            - PCIe Slot4: Intel NIC xl710 2p40GE.
-            - PCIe Slot5: Intel NIC x710 2p10GE.
-            - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
+            - PCIe Slot4: empty.
+            - PCIe Slot5: empty.
+            - PCIe Slot6: empty
         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
-2. Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
+2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
     - Quantity: 3 servers.
     - Physical connectivity:
         - CIMC and host management ports.
@@ -325,16 +493,16 @@ FD.io CSIT lab contains following server types:
         - RAM Memory: 16* 32GB DDR4-2133MHz.
         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
     - NICs configuration:
-        - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
-            - PCIe Slot1: Intel NIC xl710 2p40GE.
-            - PCIe Slot2: Intel NIC x710 2p10GE.
-            - PCIe Slot3: Intel NIC x710 2p10GE.
-        - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
-            - PCIe Slot4: Intel NIC xl710 2p40GE.
-            - PCIe Slot5: Intel NIC x710 2p10GE.
-            - PCIe Slot6: Intel NIC x710 2p10GE.
+        - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
+            - PCIe Slot1: empty.
+            - PCIe Slot2: empty.
+            - PCIe Slot3: empty.
+        - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
+            - PCIe Slot4: empty.
+            - PCIe Slot5: empty.
+            - PCIe Slot6: empty
         - MLOM slot: empty.
-3. Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
+3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
     - Quantity: 3 servers.
     - Physical connectivity:
         - CIMC and host management ports.
@@ -350,7 +518,7 @@ FD.io CSIT lab contains following server types:
         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
             - no cards.
         - MLOM slot: empty.
-4. Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
+4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
     - Quantity: ---
     - Physical connectivity:
         - IPMI and host management ports.
@@ -358,19 +526,19 @@ FD.io CSIT lab contains following server types:
     - Main HW configuration:
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+        - Processors: 2* Intel Platinum 8180 2.5 GHz.
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
     - NICs configuration:
         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
-            - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
+            - PCIe Slot9 5e:00.xx: empty.
         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-2. Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
+5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
     - Quantity: ---
     - Physical connectivity:
         - IPMI and host management ports.
@@ -378,44 +546,19 @@ FD.io CSIT lab contains following server types:
     - Main HW configuration:
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+        - Processors: 2* Intel Platinum 8180 2.5 GHz.
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
     - NICs configuration:
         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
-            - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox.
+            - PCIe Slot9 5e:00.xx: empty.
         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-3. Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
-    - Quantity: 2
-    - Physical connectivity:
-        - IPMI(?) and host management ports.
-        - NIC ports connected into 3-node topology.
-    - Main HW configuration:
-        - Chassis: Huawei TaiShan 2280.
-        - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
-        - RAM Memory: 8* 16GB DDR4-2400MT/s
-        - Disks: 1* 4TB SATA HDD
-    - NICs configuration:
-        - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
-        - PCIe Slot6 11:00.xx: 82599-2p10GE Intel.
-4. Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
-    - Quantity: 3
-    - Physical connectivity:
-        - Host management ports.
-        - NIC ports connected into 2-node and 3-node topologies.
-    - Main HW configuration:
-        - Chassis: MACCHIATObin.
-        - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
-        - RAM Memory: 1* 16GB DDR4
-        - Disks: 1* 128GB(?) SATA SDD
-    - NICs configuration:
-        - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
-5. Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
+6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
     - Quantity: TBD based on testbed allocation.
     - Physical connectivity:
         - Management: serial Port (usb) for console
@@ -428,15 +571,15 @@ FD.io CSIT lab contains following server types:
     - NICs configuration:
         - 2x 10Gb Intel 82599ES
         - 4x 1GB Intel I354
-6. Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
+7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
     - Quantity: 2.
     - Physical connectivity:
         - IPMI and host management ports.
-        - NIC ports connected into 2-node and 3-node topologies.
+        - NIC ports connected into 1-node topologies.
     - Main HW configuration:
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+        - Processors: 2* Intel Platinum 8180 2.5 GHz.
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
     - NICs configuration:
@@ -448,7 +591,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-7. Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
+8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
     - Quantity: 1.
     - Physical connectivity:
         - Host management interface: 10/100/1000-BaseT.
@@ -467,7 +610,7 @@ FD.io CSIT lab contains following server types:
         - Port-2: 10GE SFP+.
         - Port-3: 10GE SFP+.
         - Port-4: 10GE SFP+.
-8. Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
+9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
     - Quantity: 1.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -475,7 +618,7 @@ FD.io CSIT lab contains following server types:
     - Main HW configuration:
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+        - Processors: 2* Intel Platinum 8180 2.5 GHz.
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
     - NICs configuration:
@@ -487,40 +630,318 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-9. Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
-    - Quantity: 1
+10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
+    - Quantity: 4
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-E300-9A
+        - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
+        - RAM Memory: 32GB ECC
+        - Disks: 480 GB
+    - NICs configuration:
+        - 2x 10Gb Intel x553 fiber ports
+        - 2x 10Gb Intel x553 copper ports
+        - 4x 1GB Intel I350 ports
+11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
+    - Quantity: 1.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 1-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-7049GP-TRT.
+        - Motherboard: SuperMicro X11DPG-QT.
+        - Processors: 2* Intel Platinum 8280 2.7 GHz.
+        - RAM Memory: 12* 16GB DDR4-2933.
+        - Disks: 2* 1.92TB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+            - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
+            - PCIe Slot9 5e:00.xx: empty.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: empty.
+            - PCIe Slot8 af:00.xx: empty.
+            - PCIe Slot10 d8:00.xx: empty.
+12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
+    - Quantity: 3
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-7049GP-TRT.
+        - Motherboard: SuperMicro X11DPG-QT.
+        - Processors: 2* Intel Gold 6252N 2.3 GHz.
+        - RAM Memory: 12* 16GB DDR4-2933.
+        - Disks: 2* 1.92TB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+            - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
+            - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
+            - PCIe Slot8 af:00.xx: empty.
+            - PCIe Slot10 d8:00.xx: empty.
+13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
+    - Quantity: 3.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-7049GP-TRT.
+        - Motherboard: SuperMicro X11DPG-QT.
+        - Processors: 2* Intel Platinum 8280 2.7 GHz.
+        - RAM Memory: 12* 16GB DDR4-2933.
+        - Disks: 2* 1.92TB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+            - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
+            - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
+            - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
+            - PCIe Slot10 d8:00.xx: empty.
+14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
+    - Quantity: 3.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - no NIC ports, standalone setup.
+    - Main HW configuration:
+        - Chassis: SuperMicro 1029P-WTRT.
+        - Motherboard: SuperMicro X11DDW-NT.
+        - Processors: 2* Intel Platinum 8280 2.7 GHz.
+        - RAM Memory: 12* 16GB DDR4-2933.
+        - Disks: 4* 1.92TB SATA SSD.
+    - NICs configuration:
+        - Numa0:
+            - no cards.
+        - Numa1:
+            - no cards.
+15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
+    - Quantity: 1.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro AS-1114S-WTRT
+        - Processors: 1* AMD EPYC 7532 2.4 GHz.
+        - RAM Memory: 8* 32GB DDR4-2933.
+        - Disks: 1* 1TB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
+            - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
+            - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
+16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
+    - Quantity: 1.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro AS-1114S-WTRT
+        - Processors: 1* AMD EPYC 7532 2.4 GHz.
+        - RAM Memory: 8* 32GB DDR4-2933.
+        - Disks: 1* 1TB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
+            - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
+            - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
+17.  Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
+    - Quantity: 2
     - Physical connectivity:
         - IPMI and host management ports.
         - NIC ports connected into 1-node topologies.
+    - Main HW configuration:
+        - Chassis: GIGABYTE Rack Mount
+        - Motherboard: MT91-FS4-00
+        - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
+        - RAM Memory: 16 * 16GB DIMM
+        - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
+    - NICs configuration:
+        - Numa0:
+            - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
+            - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
+        - Numa1:
+            - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
+            - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
+18.  Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
+    - Quantity: 2
+    - Physical connectivity:
+        - IPMI(?) and host management ports.
+        - NIC ports connected into 3-node topology.
+    - Main HW configuration:
+        - Chassis: Huawei TaiShan 2280.
+        - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
+        - RAM Memory: 8* 16GB DDR4-2400MT/s
+        - Disks: 1* 4TB SATA HDD
+    - NICs configuration:
+        - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
+        - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
+19.  Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
+    - Quantity: 1
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node topologies.
     - Main HW configuration:
         - Chassis: Gigabyte R181-T90 1U
-        - Motheboard: MT91-FS1
-        - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
+        - Motherboard: MT91-FS1
+        - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
         - RAM Memory: 4* 32GB RDIMM
         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
     - NICs configuration:
         - Numa0:
-            - PCIe Slot1 05:00.xx: XL710-QDA2.
-            - PCIe Slot3 08:00.xx: XL710-QDA2.
+            - no cards
         - Numa1:
-            - PCIe Slot6 85:00.xx: XL710-QDA2.
-10. Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
-    - Quantity: 4
+            - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
+20.  Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
+    - Quantity: 2
     - Physical connectivity:
         - IPMI and host management ports.
-        - NIC ports.
+        - NIC ports connected into 3-node topologies.
     - Main HW configuration:
-        - Chassis: SuperMicro SYS-E300-9A
-        - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
-        - RAM Memory: 32GB ECC
-        - Disks: 480 GB
+        - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
+        - Motherboard: Mt.Jade Motherboard
+        - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
+        - RAM Memory: 16* 8GB DDR4-3200MT/s
+        - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
     - NICs configuration:
-        - 2x 10Gb Intel x553 fiber ports
-        - 2x 10Gb Intel x553 copper ports
-        - 4x 1GB Intel I350 ports
+        - Numa0:
+            - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
+        - Numa1:
+            - no cards.
+21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
+    - Quantity: 2.
+    - Physical connectivity:
+        - IPMI and host management ports.
+    - Main HW configuration:
+        - Chassis: Gigabyte R152-P30-00 1U
+        - Motherboard: MP32-AR1-00
+        - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
+        - RAM Memory: 12* 16GB DDR4-3200MT/s
+        - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
+22.  Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
+    - Quantity: 1
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node and 3-node topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-7049GP-TRT.
+        - Motherboard: SuperMicro X11DPG-QT.
+        - Processors: 2* Intel Platinum 8180 2.5 GHz.
+        - RAM Memory: 16* 16GB DDR4-2666MHz.
+        - Disks: 2* 1.6TB 6G SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+            - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
+            - PCIe Slot9 5e:00.xx: empty.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: empty.
+            - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
+            - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
+23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
+    - Quantity: 8.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node or 3-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-740GP-TNRT.
+        - Motherboard: Super X12DPG-QT6.
+        - Processors: 2* Intel Platinum 8358 2.6 GHz.
+        - RAM Memory: 16* 16GB DDR4-3200.
+        - Disks: 2* 960GB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+            - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+            - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: empty.
+            - PCIe Slot8 af:00.xx: empty.
+            - PCIe Slot10 d8:00.xx: empty.
+24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
+    - Quantity: 3.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-740GP-TNRT.
+        - Motherboard: Super X12DPG-QT6.
+        - Processors: 2* Intel Platinum 8358 2.6 GHz.
+        - RAM Memory: 16* 16GB DDR4-3200.
+        - Disks: 2* 960GB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+            - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+            - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
+            - PCIe Slot8 af:00.xx: empty.
+            - PCIe Slot10 d8:00.xx: empty.
+25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
+    - Quantity: 3.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 3-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-740GP-TNRT.
+        - Motherboard: Super X12DPG-QT6.
+        - Processors: 2* Intel Platinum 8358 2.6 GHz.
+        - RAM Memory: 16* 16GB DDR4-3200.
+        - Disks: 2* 960GB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+            - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+            - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: empty.
+            - PCIe Slot8 af:00.xx: empty.
+            - PCIe Slot10 d8:00.xx: empty.
+26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+    - Quantity: 3.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node and/or 3-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-740GP-TNRT.
+        - Motherboard: Super X12DPG-QT6.
+        - Processors: 2* Intel Platinum 8358 2.6 GHz.
+        - RAM Memory: 16* 16GB DDR4-3200.
+        - Disks: 2* 960GB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+            - PCIe Slot4 3b:00.xx: empty.
+            - PCIe Slot9 5e:00.xx: empty.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
+            - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
+            - PCIe Slot10 d8:00.xx: empty.
+27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
+    - Quantity: 2
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 3-node testbed topology.
+    - Main HW configuration:
+        - Chassis: Intel JACOBSVILLE SDP.
+        - Motherboard: Intel JACOBSVILLE E63448-400.
+        - Processors: 1* Intel Atom P5362B 2.2 GHz.
+        - RAM Memory: 2* 16GB DDR4-2933.
+        - Disks: ?* ? SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, PCIe3.0 lane)
+            - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
 ```
 
-### Server and Port Naming
+### Naming Convention
 
 Following naming convention is used within this page to specify physical
 connectivity and wiring across defined CSIT testbeds:
@@ -545,10 +966,10 @@ connectivity and wiring across defined CSIT testbeds:
 
 ### Per Testbed Server Allocation and Naming
 
-#### 1-Node-Skylake (1n-skx) PROD
+#### 1-Node-Skylake Servers (1n-skx) PROD
 
 ```
-- ServerB1 [Type-B6]:
+- SUT [Server-Type-B6]:
     - testbedname: testbed11.
     - hostname: s1-t11-sut1.
     - IPMI IP: 10.30.50.47
@@ -562,7 +983,7 @@ connectivity and wiring across defined CSIT testbeds:
         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-- ServerB2 [Type-B6]:
+- SUT [Server-Type-B6]:
     - testbedname: testbed12.
     - hostname: s2-t12-sut1.
     - IPMI IP: 10.30.50.48
@@ -578,27 +999,62 @@ connectivity and wiring across defined CSIT testbeds:
         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
 ```
 
-#### 1-Node-Thunderx2 (1n-tx2) WIP
+#### 1-Node-ThunderX2 Servers (1n-tx2) PROD
 
 ```
-- ServerB17 [Type-B9]:
-    - testbedname: testbed13.
-    - hostname: s27-t13-sut1.
-    - IPMI IP: 10.30.50.69
-    - Host IP: 10.30.51.69
+- SUT [Server-Type-E11]:
+    - testbedname: testbed13
+    - hostname: s55-t13-sut1
+    - IPMI IP: 10.30.50.70
+    - Host IP: 10.30.51.70
+    - portnames:
+        - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+        - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+        - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+        - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+        - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+        - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+        - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+        - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+- SUT [Server-Type-E11]:
+    - testbedname: testbed14
+    - hostname: s56-t14-sut1
+    - IPMI IP: 10.30.50.71
+    - Host IP: 10.30.51.71
+    - portnames:
+        - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+        - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+        - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+        - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+        - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+        - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+        - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+        - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+```
+
+#### 1-Node-Cascadelake Servers (1n-clx) PROD
+
+```
+- SUT [Server-Type-C1]:
+    - testbedname: testbed11.
+    - hostname: s32-t14-sut1.
+    - IPMI IP: 10.30.55.17
+    - Host IP: 10.32.8.17
     - portnames:
-        - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-        - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-        - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+        - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
+        - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
+        - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
+        - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
 ```
 
-#### 2-Node-Skylake (2n-skx) PROD
+#### 2-Node-Skylake Servers (2n-skx) PROD
 
 ```
-- ServerB3 [Type-B1]:
+- SUT [Server-Type-B1]:
     - testbedname: testbed21.
     - hostname: s3-t21-sut1.
     - IPMI IP: 10.30.50.41
@@ -610,9 +1066,7 @@ connectivity and wiring across defined CSIT testbeds:
         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB4 [Type-B2]:
+- TG [Server-Type-B2]:
     - testbedname: testbed21.
     - hostname: s4-t21-tg1.
     - IPMI IP: 10.30.50.42
@@ -624,9 +1078,11 @@ connectivity and wiring across defined CSIT testbeds:
         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB5 [Type-B1]:
+        - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+- SUT [Server-Type-B1]:
     - testbedname: testbed22.
     - hostname: s5-t22-sut1.
     - IPMI IP: 10.30.50.49
@@ -638,9 +1094,7 @@ connectivity and wiring across defined CSIT testbeds:
         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB6 [Type-B2]:
+- TG [Server-Type-B2]:
     - testbedname: testbed22.
     - hostname: s6-t22-tg1.
     - IPMI IP: 10.30.50.50
@@ -652,9 +1106,11 @@ connectivity and wiring across defined CSIT testbeds:
         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB7 [Type-B1]:
+        - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+- SUT [Server-Type-B1]:
     - testbedname: testbed23.
     - hostname: s7-t23-sut1.
     - IPMI IP: 10.30.50.51
@@ -666,9 +1122,7 @@ connectivity and wiring across defined CSIT testbeds:
         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB8 [Type-B2]:
+- TG [Server-Type-B2]:
     - testbedname: testbed23.
     - hostname: s8-t23-tg1.
     - IPMI IP: 10.30.50.52
@@ -680,9 +1134,11 @@ connectivity and wiring across defined CSIT testbeds:
         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB9 [Type-B1]:
+        - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+- SUT [Server-Type-B1]:
     - testbedname: testbed24.
     - hostname: s9-t24-sut1.
     - IPMI IP: 10.30.50.53
@@ -694,9 +1150,7 @@ connectivity and wiring across defined CSIT testbeds:
         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB10 [Type-B2]:
+- TG [Server-Type-B2]:
     - testbedname: testbed24.
     - hostname: s10-t24-tg1.
     - IPMI IP: 10.30.50.54
@@ -708,20 +1162,51 @@ connectivity and wiring across defined CSIT testbeds:
         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+        - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
 ```
 
-#### 2-Node-Denverton (2n-dnv) TODO
+#### 2-Node-Denverton Servers (2n-dnv) PROD
+
+Note: ServerB28 (TG) is shared between testbed26 & testbed35
 
 ```
-To be completed.
+- TG [Server-Type-B2]:
+    - testbednames: testbed26 and testbed35.
+    - hostname: s28-t26t35-tg1.
+    - IPMI IP: 10.30.55.10
+    - Host IP: 10.32.8.10
+    - portnames:
+        - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
+        - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
+        - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
+        - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
+        - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
+        - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
+        - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
+        - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
+        - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
+        - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
+        - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
+        - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
+- SUT [Server-Type-B10]:
+    - testbednames: testbed26.
+    - hostname: s29-t26-sut1.
+    - IPMI IP: 10.30.55.11
+    - Host IP: 10.32.8.11
+    - portnames:
+        - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
+        - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
+        - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
+        - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
 ```
 
-#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
+#### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
 
 ```
-- ServerB25 [Type-B8]:
+- SUT [Server-Type-B8]:
     - testbedname: testbed25.
     - hostname: s25-t25-sut1.
     - IPMI IP: 10.30.50.58
@@ -731,7 +1216,7 @@ To be completed.
         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-- ServerB26 [Type-B7]:
+- TG [Server-Type-B7]:
     - testbedname: testbed25.
     - hostname: s26-t25-tg1.
     - IPMI IP: 10.30.50.59
@@ -743,165 +1228,306 @@ To be completed.
         - s26-t25-tg1-p4 - 10GE-port4.
 ```
 
-#### 3-Node-Haswell (3n-hsw) PROD
+#### 2-Node-Cascadelake Servers (2n-clx) PROD
 
 ```
- 1. Server1 of Type-1:
-    - testbedname: testbed1.
-    - hostname: t1-sut1.
-    - CIMC IP: 10.30.50.17
-    - Host IP: 10.30.51.17
+- SUT [Server-Type-C2]:
+    - testbedname: testbed27.
+    - hostname: s33-t27-sut1.
+    - IPMI IP: 10.30.55.18
+    - Host IP: 10.32.8.18
     - portnames:
-        - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 2. Server2 of Type-1:
-    - testbedname: testbed1.
-    - hostname: t1-sut2.
-    - CIMC IP: 10.30.50.18
-    - Host IP: 10.30.51.18
+        - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+        - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
+        - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-C3]:
+    - testbedname: testbed27.
+    - hostname: s34-t27-tg1.
+    - IPMI IP: 10.30.55.19
+    - Host IP: 10.32.8.19
     - portnames:
-        - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 3. Server3 of Type-2:
-    - testbedname: testbed1.
-    - hostname: t1-tg1.
-    - CIMC IP: 10.30.50.16
-    - Host IP: 10.30.51.16
+        - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+        - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
+        - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- SUT [Server-Type-C2]:
+    - testbedname: testbed28.
+    - hostname: s35-t28-sut1.
+    - IPMI IP: 10.30.55.20
+    - Host IP: 10.32.8.20
     - portnames:
-        - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 4. Server4 of Type-1:
-    - testbedname: testbed2.
-    - hostname: t2-sut1.
-    - CIMC IP: 10.30.50.21
-    - Host IP: 10.30.51.21
+        - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+        - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
+        - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-C3]:
+    - testbedname: testbed28.
+    - hostname: s36-t28-tg1.
+    - IPMI IP: 10.30.55.21
+    - Host IP: 10.32.8.21
     - portnames:
-        - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 5. Server5 of Type-1:
-    - testbedname: testbed2.
-    - hostname: t2-sut2.
-    - CIMC IP: 10.30.50.22
-    - Host IP: 10.30.51.22
+        - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+        - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
+        - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- SUT [Server-Type-C2]:
+    - testbedname: testbed29.
+    - hostname: s37-t29-sut1.
+    - IPMI IP: 10.30.55.22
+    - Host IP: 10.32.8.22
     - portnames:
-        - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 6. Server6 of Type-2:
-    - testbedname: testbed2.
-    - hostname: t2-tg1.
-    - CIMC IP: 10.30.50.20
-    - Host IP: 10.30.51.20
+        - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
+        - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
+        - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-C3]:
+    - testbedname: testbed29.
+    - hostname: s38-t29-tg1.
+    - IPMI IP: 10.30.55.23
+    - Host IP: 10.32.8.23
     - portnames:
-        - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
- 7. Server7 of Type-1:
-    - testbedname: testbed3.
-    - hostname: t3-sut1.
-    - CIMC IP: 10.30.50.25
-    - Host IP: 10.30.51.25
+        - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+        - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
+```
+
+#### 2-Node-Zen2 Servers (2n-zn2) PROD
+
+```
+- SUT [Server-Type-D1]:
+    - testbedname: testbed210.
+    - hostname: s60-t210-sut1.
+    - IPMI IP: 10.30.55.24
+    - Host IP: 10.32.8.24
     - portnames:
-        - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 8. Server8 of Type-1:
-    - testbedname: testbed3.
-    - hostname: t3-sut2.
-    - CIMC IP: 10.30.50.26
-    - Host IP: 10.30.51.26
+        - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
+        - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
+        - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
+        - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
+        - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
+- TG [Server-Type-D2]:
+    - testbedname: testbed210.
+    - hostname: s61-t210-tg1.
+    - IPMI IP: 10.30.55.25
+    - Host IP: 10.32.8.25
     - portnames:
-        - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
-        - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
-        - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
-        - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
-        - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
-        - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
- 9. Server9 of Type-2:
-    - testbedname: testbed3.
-    - hostname: t3-tg1.
-    - CIMC IP: 10.30.50.24
-    - Host IP: 10.30.51.24
+        - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
+        - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+```
+
+#### 2-Node-ThunderX2 Servers (2x-tx2) PROD
+
+Note: Server19 (TG) is shared between testbed33 & testbed211
+
+```
+- SUT [Server-Type-E22]:
+    - testbedname: testbed211.
+    - hostname: s27-t211-sut1.
+    - IPMI IP: 10.30.50.69
+    - Host IP: 10.30.51.69
     - portnames:
-        - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
-        - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
-        - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
-        - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
-        - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+        - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+        - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+- TG [Server-Type-E31]:
+    - testbedname: testbed33 and testbed211.
+    - hostname: s19-t33t211-tg1.
+    - IPMI IP: 10.30.50.46
+    - Host IP: 10.30.51.49
+    - portnames:
+        - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+        - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
 ```
 
-#### 3-Node-Skylake (3n-skx) PROD
+#### 2-Node-Icelake Servers (2n-icx) PROD
 
 ```
-- ServerB11 [Type-B1]:
+- SUT [Server-Type-F1]:
+    - testbedname: testbed212.
+    - hostname: s71-t212-sut1.
+    - IPMI IP: 10.30.51.81
+    - Host IP: 10.30.50.81
+    - portnames:
+        - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+    - testbedname: testbed212.
+    - hostname: s72-t212-tg1.
+    - IPMI IP: 10.30.51.82
+    - Host IP: 10.30.50.82
+    - portnames:
+        - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+    - testbedname: testbed213.
+    - hostname: s83-t213-sut1.
+    - IPMI IP: 10.30.51.83
+    - Host IP: 10.30.50.83
+    - portnames:
+        - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+    - testbedname: testbed213.
+    - hostname: s84-t213-tg1.
+    - IPMI IP: 10.30.51.84
+    - Host IP: 10.30.50.84
+    - portnames:
+        - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+    - testbedname: testbed214.
+    - hostname: s85-t214-sut1.
+    - IPMI IP: 10.30.51.85
+    - Host IP: 10.30.50.85
+    - portnames:
+        - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+    - testbedname: testbed214.
+    - hostname: s86-t214-tg1.
+    - IPMI IP: 10.30.51.86
+    - Host IP: 10.30.50.86
+    - portnames:
+        - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+    - testbedname: testbed215.
+    - hostname: s87-t215-sut1.
+    - IPMI IP: 10.30.51.87
+    - Host IP: 10.30.50.87
+    - portnames:
+        - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+    - testbedname: testbed215.
+    - hostname: s88-t215-tg1.
+    - IPMI IP: 10.30.51.88
+    - Host IP: 10.30.50.88
+    - portnames:
+        - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+```
+
+#### 3-Node-Skylake Servers (3n-skx) PROD
+
+```
+- ServerB11 [Server-Type-B1]:
     - testbedname: testbed31.
     - hostname: s11-t31-sut1.
     - IPMI IP: 10.30.50.43
@@ -913,9 +1539,7 @@ To be completed.
         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB12 [Type-B1]:
+- ServerB12 [Server-Type-B1]:
     - testbedname: testbed31.
     - hostname: s12-t31-sut2.
     - IPMI IP: 10.30.50.44
@@ -927,9 +1551,7 @@ To be completed.
         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB13 [Type-B2]:
+- ServerB13 [Server-Type-B2]:
     - testbedname: testbed31.
     - hostname: s13-t31-tg1.
     - IPMI IP: 10.30.50.45
@@ -941,9 +1563,11 @@ To be completed.
         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB14 [Type-B1]:
+        - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+- ServerB14 [Server-Type-B1]:
     - testbedname: testbed32.
     - hostname: s14-t32-sut1.
     - IPMI IP: 10.30.50.55
@@ -955,9 +1579,7 @@ To be completed.
         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB15 [Type-B1]:
+- ServerB15 [Server-Type-B1]:
     - testbedname: testbed32.
     - hostname: s15-t32-sut2.
     - IPMI IP: 10.30.50.56
@@ -969,9 +1591,7 @@ To be completed.
         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
-- ServerB16 [Type-B2]:
+- ServerB16 [Server-Type-B2]:
     - testbedname: testbed32.
     - hostname: s16-t32-tg1.
     - IPMI IP: 10.30.50.57
@@ -983,18 +1603,18 @@ To be completed.
         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+        - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
 ```
 
-Note: ServerB19 (TG) is shared between testbed33 & testbed34
-
-#### 3-Node-Rangeley (3n-rng) VERIFY
+#### 3-Node-Rangeley Servers (3n-rng) VERIFY
 
 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
 
 ```
-- ServerB22 [Type-B5]:
+- ServerB22 [Server-Type-B5]:
     - testbedname: testbed35.
     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
@@ -1003,7 +1623,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
     - 1GB ports (tbd)
-- ServerB23 [Type-B5]:
+- ServerB23 [Server-Type-B5]:
     - testbedname: testbed35.
     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
@@ -1012,7 +1632,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
     - 1GB ports (tbd)
-- ServerB24 [Type-B5]:
+- ServerB24 [Server-Type-B5]:
     - testbedname: testbed35.
     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
@@ -1023,72 +1643,240 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
     - 1GB ports (tbd)
 ```
 
-#### 3-Node-Taishan (3n-tsh) WIP
+#### 3-Node-Taishan Servers (3n-tsh) PROD
+
+Note: Server19 (TG) is shared between testbed33 & testbed211
 
 ```
-- ServerB17 [Type-B3]:
+- SUT [Server-Type-E21]:
     - testbedname: testbed33.
     - hostname: s17-t33-sut1.
     - IPMI IP: 10.30.50.36
     - Host IP: 10.30.51.36
     - portnames:
-        - s17-t33-sut1-c6/p1 - 10GE-port1 82599-2p10GE.
-        - s17-t33-sut1-c6/p2 - 10GE-port2 82599-2p10GE.
+        - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
+        - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
-- ServerB18 [Type-B3]:
+- SUT [Server-Type-E21]:
     - testbedname: testbed33.
     - hostname: s18-t33-sut2.
     - IPMI IP: 10.30.50.37
     - Host IP: 10.30.51.37
     - portnames:
-        - s18-t33-sut2-c6/p1 - 10GE-port1 82599-2p10GE.
-        - s18-t33-sut2-c6/p2 - 10GE-port2 82599-2p10GE.
+        - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
+        - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
-- ServerB19 [Type-B2]:
-    - testbednames: testbed33 and testbed34.
-    - hostname: s19-t33t34-tg1.
+- TG [Server-Type-E31]:
+    - testbedname: testbed33 and testbed211.
+    - hostname: s19-t33t211-tg1.
     - IPMI IP: 10.30.50.46
     - Host IP: 10.30.51.49
     - portnames:
-        - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-- ServerB20 [Type-B4]:
+        - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+        - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+```
+
+#### 3-Node-Altra Servers (3n-alt) PROD
+
+```
+- SUT [Server-Type-E23]:
+    - testbedname: testbed34.
+    - hostname: s62-t34-sut1.
+    - IPMI IP: 10.30.50.72
+    - Host IP: 10.30.51.72
+    - portnames:
+        - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+- SUT [Server-Type-E23]:
     - testbedname: testbed34.
-    - hostname: s20-t34-sut1.
-    - IPMI IP: N/A
-    - Host IP: 10.30.51.41
+    - hostname: s63-t34-sut2.
+    - IPMI IP: 10.30.50.73
+    - Host IP: 10.30.51.73
     - portnames:
-        - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
-        - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
-- ServerB21 [Type-B4]:
+        - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+- TG [Server-Type-F4]:
     - testbedname: testbed34.
-    - hostname: s21-t34-sut2.
-    - IPMI IP: N/A
-    - Host IP: 10.30.51.42
+    - hostname: s64-t34-tg1.
+    - IPMI IP: 10.30.50.74
+    - Host IP: 10.30.51.74
     - portnames:
-        - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
-        - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
+        - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+        - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 ```
 
-#### 3-Node-Mcbin (3n-mcb) TODO
+#### 3-Node-Denverton Servers (3n-dnv) PROD
 
 ```
-To be completed.
+- ServerB30 [Server-Type-B10]:
+    - testbednames: testbed35.
+    - hostname: s30-t35-sut1.
+    - IPMI IP: 10.30.55.12
+    - Host IP: 10.32.8.12
+    - portnames:
+        - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
+        - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
+        - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
+        - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
+- ServerB31 [Server-Type-B10]:
+    - testbednames: testbed35.
+    - hostname: s31-t35-sut2.
+    - IPMI IP: 10.30.55.13
+    - Host IP: 10.32.8.13
+    - portnames:
+        - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
+        - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
+        - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
+        - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
+```
+
+#### 3-Node-Icelake Servers (3n-icx) PROD
+
+```
+- ServerF1 [Server-Type-F1]:
+    - testbedname: testbed37.
+    - hostname: s65-t37-sut1.
+    - IPMI IP: 10.30.50.75
+    - Host IP: 10.30.51.75
+    - portnames:
+        - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+    - testbedname: testbed37.
+    - hostname: s66-t37-sut2.
+    - IPMI IP: 10.30.50.76
+    - Host IP: 10.30.51.76
+    - portnames:
+        - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF3 [Server-Type-F3]:
+    - testbedname: testbed37.
+    - hostname: s67-t37-tg1.
+    - IPMI IP: 10.30.50.77
+    - Host IP: 10.30.51.77
+    - portnames:
+        - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+    - testbedname: testbed38.
+    - hostname: s78-t38-sut1.
+    - IPMI IP: 10.30.50.78
+    - Host IP: 10.30.51.78
+    - portnames:
+        - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+    - testbedname: testbed38.
+    - hostname: s79-t38-sut2.
+    - IPMI IP: 10.30.50.79
+    - Host IP: 10.30.51.79
+    - portnames:
+        - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF3 [Server-Type-F3]:
+    - testbedname: testbed38.
+    - hostname: s80-t38-tg1.
+    - IPMI IP: 10.30.50.80
+    - Host IP: 10.30.51.80
+    - portnames:
+        - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+```
+
+#### 3-Node-SnowRidge Servers (3n-snr) PROD
+
+```
+- ServerG1 [Server-Type-G1]:
+    - testbedname: testbed39.
+    - hostname: s93-t39-sut1.
+    - IPMI IP: 10.30.50.93
+    - Host IP: 10.30.51.93
+    - portnames:
+        - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerG1 [Server-Type-G1]:
+    - testbedname: testbed39.
+    - hostname: s94-t39-sut2.
+    - IPMI IP: 10.30.50.94
+    - Host IP: 10.30.51.94
+    - portnames:
+        - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerF4 [Server-Type-F4]:
+    - testbedname: testbed39.
+    - hostname: s89-t39t310-tg1.
+    - IPMI IP: 10.30.50.89
+    - Host IP: 10.30.51.89
+    - portnames:
+        - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
 ```
 
 ### Per Testbed Wiring
 
-#### 1-Node-Skylake (1n-skx) PROD
+#### 1-Node-Skylake Wiring (1n-skx) PROD
 
 ```
 - testbed11:
@@ -1099,7 +1887,11 @@ To be completed.
     - ring3 10GE-ports x710-4p10GE:
         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
     - ring4 10GE-ports x710-4p10GE:
-        - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
+        - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
+    - ring5 100GE-ports e810-2p100GE:
+        - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
+    - ring6 100GE-ports e810-2p100GE:
+        - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
 - testbed12:
     - ring1 10GE-ports x710-4p10GE:
         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
@@ -1108,22 +1900,38 @@ To be completed.
     - ring3 10GE-ports x710-4p10GE:
         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
     - ring4 10GE-ports x710-4p10GE:
-        - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
+        - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
+    - ring5 100GE-ports e810-2p100GE:
+        - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
+    - ring6 100GE-ports e810-2p100GE:
+        - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
 ```
 
-#### 1-Node-Thunderx2 (1n-tx2) WIP
+#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
 
 ```
 - testbed13:
     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
-        - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
+        - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
-        - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
-    - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
-        - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
+        - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
+    - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
+        - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
+    - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
+        - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
+
+- testbed14:
+    - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
+        - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
+    - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
+        - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
+    - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
+        - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
+    - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
+        - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
 ```
 
-#### 2-Node-Skylake (2n-skx) PROD
+#### 2-Node-Skylake Wiring (2n-skx) PROD
 
 ```
 - testbed21:
@@ -1136,10 +1944,7 @@ To be completed.
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1.
-        - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
         - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
         - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
 - testbed22:
@@ -1152,10 +1957,7 @@ To be completed.
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1.
-        - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
         - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
         - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
 - testbed23:
@@ -1168,10 +1970,7 @@ To be completed.
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1.
-        - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
         - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
         - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
 - testbed24:
@@ -1184,21 +1983,24 @@ To be completed.
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
-    - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1.
-        - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2.
-    - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
         - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
         - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
 ```
 
-#### 2-Node-Denverton (2n-dnv) TODO
+#### 2-Node-Denverton Wiring (2n-dnv) PROD
 
 ```
-To be completed.
+- testbed26:
+    - ring1 10GE-ports x553 copper port on SUT:
+        - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
+        - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
+    - ring2 10GE-ports x553 fiber port on SUT:
+        - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
+        - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
 ```
 
-#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY
+#### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
 
 ```
 - testbed25:
@@ -1212,83 +2014,158 @@ To be completed.
         - t25-tg1-p4 to t25-sut1-c2/p4.
 ```
 
-#### 3-Node-Haswell (3n-hsw) PROD
-
-```
- 1. testbed1:
-    - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
-        - t1-tg1-c1/p1 to t1-sut1-c1/p2.
-        - t1-sut1-c1/p1 to t1-sut2-c1/p2.
-        - t1-sut2-c1/p1 to t1-tg1-c1/p2.
-    - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
-        - t1-tg1-c2/p1 to t1-sut1-c2/p2.
-        - t1-sut1-c2/p1 to t1-sut2-c2/p2.
-        - t1-sut2-c2/p1 to t1-tg1-c2/p2.
-    - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
-        - t1-tg1-c4/p1 to t1-sut1-c4/p2.
-        - t1-sut1-c4/p1 to t1-sut2-c4/p2.
-        - t1-sut2-c4/p1 to t1-tg1-c4/p2.
-    - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
-        - t1-tg1-c5/p1 to t1-sut1-c5/p2.
-        - t1-sut1-c5/p1 to t1-sut2-c5/p2.
-        - t1-sut2-c5/p1 to t1-tg1-c5/p2.
-    - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
-        - t1-tg1-c2/p1 to t1-sut1-cm/p2.
-        - t1-sut1-cm/p1 to t1-sut2-cm/p2.
-        - t1-sut2-cm/p1 to t1-tg1-c2/p2.
-    - TG loopback ports Intel NIC x710 2p10GE
-        - t1-tg1-c6/p1 to t1-tg1-c6/p2.
-
- 2. testbed2:
-    - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
-        - t2-tg1-c1/p1 to t2-sut1-c1/p2.
-        - t2-sut1-c1/p1 to t2-sut2-c1/p2.
-        - t2-sut2-c1/p1 to t2-tg1-c1/p2.
-    - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
-        - t2-tg1-c2/p1 to t2-sut1-c2/p2.
-        - t2-sut1-c2/p1 to t2-sut2-c2/p2.
-        - t2-sut2-c2/p1 to t2-tg1-c2/p2.
-    - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
-        - t2-tg1-c4/p1 to t2-sut1-c4/p2.
-        - t2-sut1-c4/p1 to t2-sut2-c4/p2.
-        - t2-sut2-c4/p1 to t2-tg1-c4/p2.
-    - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
-        - t2-tg1-c5/p1 to t2-sut1-c5/p2.
-        - t2-sut1-c5/p1 to t2-sut2-c5/p2.
-        - t2-sut2-c5/p1 to t2-tg1-c5/p2.
-    - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
-        - t2-tg1-c2/p1 to t2-sut1-cm/p2.
-        - t2-sut1-cm/p1 to t2-sut2-cm/p2.
-        - t2-sut2-cm/p1 to t2-tg1-c2/p2.
-    - TG loopback ports Intel NIC x710 2p10GE
-        - t2-tg1-c6/p1 to t2-tg1-c6/p2.
-
- 3. testbed3:
-    - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
-        - t3-tg1-c1/p1 to t3-sut1-c1/p2.
-        - t3-sut1-c1/p1 to t3-sut2-c1/p2.
-        - t3-sut2-c1/p1 to t3-tg1-c1/p2.
-    - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
-        - t3-tg1-c2/p1 to t3-sut1-c2/p2.
-        - t3-sut1-c2/p1 to t3-sut2-c2/p2.
-        - t3-sut2-c2/p1 to t3-tg1-c2/p2.
-    - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
-        - t3-tg1-c4/p1 to t3-sut1-c4/p2.
-        - t3-sut1-c4/p1 to t3-sut2-c4/p2.
-        - t3-sut2-c4/p1 to t3-tg1-c4/p2.
-    - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
-        - t3-tg1-c5/p1 to t3-sut1-c5/p2.
-        - t3-sut1-c5/p1 to t3-sut2-c5/p2.
-        - t3-sut2-c5/p1 to t3-tg1-c5/p2.
-    - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
-        - t3-tg1-c2/p1 to t3-sut1-cm/p2.
-        - t3-sut1-cm/p1 to t3-sut2-cm/p2.
-        - t3-sut2-cm/p1 to t3-tg1-c2/p2.
-    - TG loopback ports Intel NIC x710 2p10GE
-        - t3-tg1-c6/p1 to t3-tg1-c6/p2.
-```
-
-#### 3-Node-Skylake (3n-skx) PROD
+#### 2-Node-Cascadelake Wiring (2n-clx) PROD
+
+```
+- testbed27:
+    - ring1 10GE-ports x710-4p10GE on SUT:
+        - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
+        - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
+    - ring2 10GE-ports x710-4p10GE on SUT:
+        - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
+        - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
+    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
+        - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
+    - ring4 100GE-ports ConnectX5-2p100GE on SUT:
+        - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
+        - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
+    - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
+        - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
+        - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
+    - ring6 100GE-ports e810-2p100GE on TG:
+        - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
+        - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
+- testbed28:
+    - ring1 10GE-ports x710-4p10GE on SUT:
+        - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
+        - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
+    - ring2 10GE-ports x710-4p10GE on SUT:
+        - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
+        - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
+    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
+        - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
+    - ring4 100GE-ports ConnectX5-2p100GE on SUT:
+        - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
+        - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
+    - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
+        - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
+        - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
+    - ring6 100GE-ports e810-2p100GE on TG:
+        - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
+        - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
+- testbed29:
+    - ring1 10GE-ports x710-4p10GE on SUT:
+        - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
+        - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
+    - ring2 10GE-ports x710-4p10GE on SUT:
+        - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
+        - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
+    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
+        - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
+    - ring4 100GE-ports ConnectX5-2p100GE on SUT:
+        - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
+        - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
+    - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
+        - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
+        - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
+```
+
+#### 2-Node-Zen2 Wiring (2n-zn2) PROD
+
+```
+- testbed210:
+    - ring1 10GE-ports x710-4p10GE on SUT:
+        - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
+        - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
+    - ring2 10GE-ports x710-4p10GE on SUT:
+        - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
+        - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
+    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
+        - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
+    - ring4 100GE-ports ConnectX5-2p100GE on SUT:
+        - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
+        - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
+```
+
+#### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
+
+```
+- testbed211:
+    - ring1 10GE-ports x520-2p10GE on SUTs:
+        - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
+        - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
+```
+
+#### 2-Node-Icelake Wiring (2n-icx) PROD
+
+```
+- testbed212:
+    - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
+        - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
+    - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+        - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
+        - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
+        - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
+        - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
+    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
+        - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
+    - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
+        - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
+- testbed213:
+    - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
+        - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
+    - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+        - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
+        - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
+        - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
+        - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
+    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
+        - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
+    - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
+        - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
+- testbed214:
+    - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
+        - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
+    - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+        - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
+        - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
+        - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
+        - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
+    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
+        - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
+    - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
+        - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
+- testbed215:
+    - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
+        - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
+    - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+        - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
+        - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
+        - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
+        - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
+    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
+        - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
+    - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
+        - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
+```
+
+#### 3-Node-Skylake Wiring (3n-skx) PROD
 
 ```
 - testbed31:
@@ -1333,34 +2210,98 @@ To be completed.
         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
 ```
 
-#### 3-Node-Rangeley (3n-rng) TODO
+#### 3-Node-Rangeley Wiring (3n-rng) VERIFY
 
 ```
 To be completed.
 ```
 
-#### 3-Node-Taishan (3n-tsh) WIP
+#### 3-Node-Taishan Wiring (3n-tsh) PROD
 
 ```
 - testbed33:
-    - ring1 10GE-ports 82599-2p10GE on SUTs:
-        - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
-        - t33-sut1-c6/p1 - t33-sut2-c6/p2.
-        - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
+    - ring1 10GE-ports x520-2p10GE on SUTs:
+        - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
+        - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
+        - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
     - ring2 25GE-ports cx4-2p25GE on SUTs:
-        - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
-        - t33-sut1-c4/p1 - t33-sut2-c4/p2.
-        - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
+        - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
+        - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
+        - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
 ```
 
-#### 3-Node-Mcbin (3n-mcb) WIP
+#### 3-Node-Altra Wiring (3n-alt) PROD
 
 ```
 - testbed34:
-    - ring1 10GE-ports Marvell on SUTs:
-        - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
-        - t34-sut1-ca/p2 - t34-sut2-ca/p1.
-        - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
+    - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
+        - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
+        - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
+        - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
+```
+
+#### 3-Node-Denverton Wiring (3n-dnv) PROD
+
+```
+- testbed35:
+    - ring1 10GE-ports x553 copper port on SUTs:
+        - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
+        - s30-t35-sut1-p1 to s31-t35-sut2-p1.
+        - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
+    - ring2 10GE-ports x553 fiber port on SUTs:
+        - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
+        - s30-t35-sut1-p3 to s31-t35-sut2-p3.
+        - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
+```
+
+#### 3-Node-Icelake Wiring (3n-icx) PROD
+
+```
+- testbed37:
+    - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
+        - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
+        - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
+        - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
+    - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
+        - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
+        - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
+        - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
+        - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
+        - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
+        - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
+    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
+        - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
+        - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
+        - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
+- testbed38:
+    - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
+        - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
+        - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
+        - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
+    - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
+        - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
+        - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
+        - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
+        - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
+        - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
+        - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
+    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
+        - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
+        - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
+        - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
+```
+
+#### 3-Node-SnowRidge Wiring (3n-snr) PROD
+
+```
+- testbed39:
+    - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
+        - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
+        - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
+        - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
+        - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
+        - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
+        - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
 ```
 
 ## Inventory
@@ -1380,25 +2321,39 @@ To be completed.
         - Operating System: Native IxOS.
 ```
 
-### Arm Servers
+### Arm Servers
 
 ```
 1. Arm Cortex A-72 servers
-    - 1 * ThunderX2
-        - Chassis: Marvell ThunderX2
-        - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
+    - 2 * ThunderX2 (VPP Device)
+        - Chassis: GIGABYTE Rack Mount
+        - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
+        - RAM Memory: 16* 16GB DIMM
+        - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
+    - 1 * ThunderX2 (Performance)
+        - Chassis: GIGABYTE Rack Mount
+        - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
         - RAM Memory: 4* 32GB RDIMM
         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
     - 2 * Huawei TaiShan 2280.
         - Chassis: Huawei TaiShan 2280.
-        - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
+        - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
         - RAM Memory: 8* 16GB DDR4-2400MT/s.
         - Disks: 1* 4TB SATA HDD.
-    - 3 * MACCHIATObin
-        - Chassis: MACCHIATObin.
-        - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
-        - RAM Memory: 1* 16GB DDR4.
-        - Disks: 1* 128GB(?) SATA SDD.
+2. Arm Neoverse N1 servers
+    - 2 * Ampere Altra (Performance)
+        - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
+        - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
+        - RAM Memory: 16* 8GB DDR4-3200MT/s
+        - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
+    - 2 * Ampere Altra (Build)
+        - Chassis: Gigabyte R152-P30-00 1U
+        - Motherboard: MP32-AR1-00
+        - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
+        - RAM Memory: 12* 16GB DDR4-3200MT/s
+        - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
 ```
 
 ### Xeon and Atom Servers
@@ -1408,7 +2363,7 @@ To be completed.
     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
         - Chassis: SuperMicro SYS-7049GP-TRT.
         - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.3 GHz.
+        - Processors: 2* Intel Platinum 8180 2.5 GHz.
         - RAM Memory: 16* 16GB DDR4-2666MHz.
         - Disks: 2* 1.6TB 6G SATA SSD.
 2. Intel Atom servers with Rangely processors.
@@ -1423,15 +2378,13 @@ To be completed.
 
 ```
 1. 10GE NICs
-    - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
-    - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
-    - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
+    - ?
 2. 25GE NICs
-    - 12 * Intel® Ethernet Network Adapter XXV710-DA2
+    - ?
 3. 40GE NICs
-    - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
+    - ?
 4. 100GE NICs
-    - 4 * mcx556a-edat NICs (not on site yet, in transit)
+    - ?
 ```
 
 ### Pluggables and Cables
@@ -1440,27 +2393,26 @@ Pluggables:
 
 ```
 1. 10GE SFP+
-    - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
-    - 80 * 10G SR optic (generic, "Intel" compatible branded)
+    - ?
 2. 25GE SFP28
-    - None
+    - ?
 3. 40GE QSFP+
-    - None
+    - ?
 4. 100GE
-    - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
+    - ?
 ```
 
 Standalone cables:
 
 ```
 1. 10GE
-    - None
+    - ?
 2. 25GE
-    - None
+    - ?
 3. 40GE QSFP+
-    - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
+    - ?
 4. 100GE
-    - None
+    - ?
 ```
 
 ### Other Parts