Revert "fix(jobspec): Delete ipsec nfv density tests"
[csit.git] / docs / lab / testbed_specifications.md
diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md
deleted file mode 100644 (file)
index e8ea401..0000000
+++ /dev/null
@@ -1,1823 +0,0 @@
-# FD.io CSIT Testbed Specifications
-
-1. [Purpose](#purpose)
-1. [Testbeds Overview](#testbeds-overview)
-   1. [Summary List](#summary-list)
-   1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
-   1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
-   1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
-   1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
-   1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
-   1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
-   1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
-   1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
-   1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
-   1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
-   1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
-   1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
-   1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
-   1. [2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)](#2-node-full-sapphirerapids-xeon-intel-2nf-spr)
-   1. [2-Node-SapphireRapids Xeon Intel (2n-spr)](#2-Node-SapphireRapids-Xeon-Intel-2n-spr)
-1. [Server Management](#server-management)
-   1. [Requirements](#requirements)
-   1. [Addressing](#addressing)
-   1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
-   1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
-1. [Server Specifications](#server-specifications)
-   1. [Server Types](#server-types)
-   1. [Naming Convention](#naming-convention)
-1. [Testbeds Configuration](#testbeds-configuration)
-   1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
-      1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
-      1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
-      1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
-      1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
-      1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
-      1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
-      1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
-      1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
-      1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
-      1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
-      1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
-      1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
-      1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
-      1. ...
-      1. ...
-   1. [Per Testbed Wiring](#per-testbed-wiring)
-      1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
-      1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
-      1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
-      1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
-      1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
-      1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
-      1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
-      1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
-      1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
-      1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
-      1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
-      1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
-      1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
-      1. ...
-      1. ...
-1. [Inventory](#inventory)
-   1. [Appliances](#appliances)
-   1. [Arm Servers](#arm-servers)
-   1. [Xeon and Atom Servers](#xeon-and-atom-servers)
-   1. [Network Interface Cards](#network-interface-cards)
-   1. [Pluggables and Cables](#pluggables-and-cables)
-   1. [Other Parts](#other-parts)
-
-## Purpose
-
-This note includes specification of the physical testbed infrastructure
-hosted by LFN FD.io CSIT project.
-
-## Testbeds Overview
-
-### Summary List
-
-```
- #. Type             Purpose  SUT   TG    #TB  #SUT #TG  #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr
- 1. 1-Node-Skylake     nomad  skx   na    5    5    0    5    0    0    0    0    0    0    0    0    0
- 2. 1-Node-Cascadelake nomad  clx   na    1    1    0    0    0    0    0    0    0    1    0    0    0
- 3. 1-Node-AmpereAltra nomad  alt   na    2    2    0    0    0    0    0    0    2    0    0    0    0
- 4. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    1    1    0    0    0    0    0    0    0    0
- 5. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    6    0    0    0
- 6. 2-Node-ThunderX2   perf   tx2   skx   1    1    .5   .5   0    0    1    0    0    0    0    0    0
- 7. 2-Node-Icelake     perf   icx   icx   4    4    4    0    0    0    0    0    0    0    0    8    0
- 8. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    2    0    0    0    0    0    0    0
- 9. 3-Node-Taishan     perf   tsh   skx   1    2    .5   .5   0    0    0    2    0    0    0    0    0
-10. 3-Node-Altra       perf   alt   icx   1    2    1    0    0    0    0    0    2    0    0    1    0
-11. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    2    0    0
-12. 3-Node-Icelake     perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    6    0
-13. 3-Node-SnowRidge   perf   snr   icx   1    2    .5   0    0    0    0    0    0    0    0    .5   2
-                                 Totals: 23   31  14.5   7    1    2    1    2    4    7    2  15.5   2
-```
-
-### 1-Node-Skylake Xeon Intel (1n-skx)
-
-Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
-ports connected back-to-back ([Server Types](#server-types)).
-Used for FD.io VPP_Device functional driver tests.
-
-### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
-
-Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
-ports connected back-to-back ([Server Types](#server-types)).
-Used for FD.io VPP_Device functional driver tests.
-
-### 1-Node-Cascadelake Xeon Intel (1n-clx)
-
-Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
-NIC ports connected back-to-back ([Server Types](#server-types)).
-
-Used for FD.io VPP_Device functional driver tests.
-
-### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
-
-Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
-TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
-circular topology ([Server Types](#server-types)).
-Used for FD.io TCP/IP and HTTP performance tests.
-
-### 2-Node-Cascadelake Xeon Intel (2n-clx)
-
-Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
-one TG (Server-Type-C3) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-Zen2 EPYC AMD (2n-zn2)
-
-Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
-one TG (Server-Type-D2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
-
-Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
-one TG (Server-Type-E31) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-Icelake Xeon Intel (2n-icx)
-
-Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
-one TG (Server-Type-F2) connected in a 2-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-Rangeley Atom Testbeds
-
-Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
-TG (Server-Type-2) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-TaiShan Arm Huawei (3n-tsh)
-
-Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
-TG (Server-Type-E31) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-Altra Arm Ampere (3n-alt)
-
-Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
-TG (Server-Type-F4) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-Icelake Xeon Intel (3n-icx)
-
-Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
-TG (Server-Type-F3) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 3-Node-SnowRidge Atom Intel (3n-snr)
-
-Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
-TG (Server-Type-F4) connected in a 3-node circular topology
-([Server Types](#server-types)).
-Used for FD.io performance tests.
-
-### 2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)
-
-One 2-Node-Full-SapphireRapids testbed includes one SUT (Server-Type-TODO) and
-one TG (Server-Type-TODO) connected in a 2-node physical topology with NUMA (socket) daisy chaining. For more detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
-Used for FD.io performance tests in a full system SUT setup with all PCIe Gen5 x16 lane slots populated with 2p200GbE NICs.
-
-### 2-Node-SapphireRapids Xeon Intel (2n-spr)
-
-Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-TODO) and
-one TG (Server-Type-TODO) connected in a 2-node circular topology. For more detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
-Used for FD.io performance tests.
-
-## Server Management
-
-### Requirements
-
-For management purposes, each server must have following two ports
-connected to the management network:
-
-```
-- 1GE IPMI port
-  - IPMI - Intelligent Platform Management Interface.
-  - Required for access to embedded server management with WebUI, CLI,
-    SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
-- 1GE/10GE/40GE management port
-  - hostOS management port for general system management.
-```
-
-### Addressing
-
-Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
-Management port, which are connected to two different VLANs.
-
-```
-1. LOM (IPMI) VLAN:
-    - Subnet: 10.30.50.0/24
-    - Gateway: 10.30.50.1
-    - Broadcast: 10.30.50.255
-    - DNS1: 199.204.44.24
-    - DNS2: 199.204.47.54
-2. Management Vlan:
-    - Subnet: 10.30.51.0/24
-    - Gateway: 10.30.51.1
-    - Broadcast: 10.30.51.255
-    - DNS1: 199.204.44.24
-    - DNS2: 199.204.47.54
-```
-
-To access these hosts, VPN connection is required.
-
-## Server Specifications
-
-### Server Types
-
-FD.io CSIT lab contains following server types:
-```
-1. Server-Type-B2: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
-    - Quantity: ---
-    - Physical connectivity:
-        - IPMI and host management ports.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.5 GHz.
-        - RAM Memory: 16* 16GB DDR4-2666MHz.
-        - Disks: 2* 1.6TB 6G SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot2 18:00.xx: empty.
-            - PCIe Slot4 3b:00.xx: empty.
-            - PCIe Slot9 5e:00.xx: empty.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: empty.
-2. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
-    - Quantity: 2.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 1-node topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.5 GHz.
-        - RAM Memory: 16* 16GB DDR4-2666MHz.
-        - Disks: 2* 1.6TB 6G SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
-            - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
-            - PCIe Slot9 5e:00.xx: empty.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: empty.
-3. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
-    - Quantity: 1.
-    - Physical connectivity:
-        - Host management interface: 10/100/1000-BaseT.
-        - 8-port 10GE SFP+ integrated NIC.
-    - Main HW configuration:
-        - Chassis: PS10GE4NG.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: Quad-Core, Intel Processor.
-        - HW accelerators: FPGA offload.
-        - RAM Memory: 64GB.
-        - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
-        - Physical Interfaces: 4 * 10GE SFP+.
-        - Operating System: Native IxOS.
-    - Interface configuration:
-        - Port-1: 10GE SFP+.
-        - Port-2: 10GE SFP+.
-        - Port-3: 10GE SFP+.
-        - Port-4: 10GE SFP+.
-4. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
-    - Quantity: 1.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.5 GHz.
-        - RAM Memory: 16* 16GB DDR4-2666MHz.
-        - Disks: 2* 1.6TB 6G SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
-            - PCIe Slot4 3b:00.xx: empty.
-            - PCIe Slot9 5e:00.xx: empty.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: empty.
-5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
-    - Quantity: 1.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 1-node testbed topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8280 2.7 GHz.
-        - RAM Memory: 12* 16GB DDR4-2933.
-        - Disks: 2* 1.92TB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
-            - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
-            - PCIe Slot9 5e:00.xx: empty.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: empty.
-6. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
-    - Quantity: 3
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node testbed topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Gold 6252N 2.3 GHz.
-        - RAM Memory: 12* 16GB DDR4-2933.
-        - Disks: 2* 1.92TB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
-            - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
-            - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: empty.
-7. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
-    - Quantity: 3.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node testbed topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8280 2.7 GHz.
-        - RAM Memory: 12* 16GB DDR4-2933.
-        - Disks: 2* 1.92TB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
-            - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
-            - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
-            - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
-            - PCIe Slot10 d8:00.xx: empty.
-8. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
-    - Quantity: 3.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - no NIC ports, standalone setup.
-    - Main HW configuration:
-        - Chassis: SuperMicro 1029P-WTRT.
-        - Motherboard: SuperMicro X11DDW-NT.
-        - Processors: 2* Intel Platinum 8280 2.7 GHz.
-        - RAM Memory: 12* 16GB DDR4-2933.
-        - Disks: 4* 1.92TB SATA SSD.
-    - NICs configuration:
-        - Numa0:
-            - no cards.
-        - Numa1:
-            - no cards.
-9. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
-    - Quantity: 1.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node testbed topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro AS-1114S-WTRT
-        - Processors: 1* AMD EPYC 7532 2.4 GHz.
-        - RAM Memory: 8* 32GB DDR4-2933.
-        - Disks: 1* 1TB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
-            - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
-            - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-10. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
-    - Quantity: 1.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node testbed topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro AS-1114S-WTRT
-        - Processors: 1* AMD EPYC 7532 2.4 GHz.
-        - RAM Memory: 8* 32GB DDR4-2933.
-        - Disks: 1* 1TB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-            - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
-            - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
-11.  Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
-    - Quantity: 2
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 1-node topologies.
-    - Main HW configuration:
-        - Chassis: GIGABYTE Rack Mount
-        - Motherboard: MT91-FS4-00
-        - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
-        - RAM Memory: 16 * 16GB DIMM
-        - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
-    - NICs configuration:
-        - Numa0:
-            - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
-            - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
-        - Numa1:
-            - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
-            - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
-12.  Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
-    - Quantity: 2
-    - Physical connectivity:
-        - IPMI(?) and host management ports.
-        - NIC ports connected into 3-node topology.
-    - Main HW configuration:
-        - Chassis: Huawei TaiShan 2280.
-        - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
-        - RAM Memory: 8* 16GB DDR4-2400MT/s
-        - Disks: 1* 4TB SATA HDD
-    - NICs configuration:
-        - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
-        - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
-13.  Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
-    - Quantity: 1
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node topologies.
-    - Main HW configuration:
-        - Chassis: Gigabyte R181-T90 1U
-        - Motherboard: MT91-FS1
-        - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
-        - RAM Memory: 4* 32GB RDIMM
-        - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
-    - NICs configuration:
-        - Numa0:
-            - no cards
-        - Numa1:
-            - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
-14.  Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
-    - Quantity: 2
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 3-node topologies.
-    - Main HW configuration:
-        - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
-        - Motherboard: Mt.Jade Motherboard
-        - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
-        - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
-        - RAM Memory: 16* 8GB DDR4-3200MT/s
-        - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
-    - NICs configuration:
-        - Numa0:
-            - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
-        - Numa1:
-            - no cards.
-15. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
-    - Quantity: 2.
-    - Physical connectivity:
-        - IPMI and host management ports.
-    - Main HW configuration:
-        - Chassis: Gigabyte R152-P30-00 1U
-        - Motherboard: MP32-AR1-00
-        - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
-        - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
-        - RAM Memory: 12* 16GB DDR4-3200MT/s
-        - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
-16.  Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
-    - Quantity: 1
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node and 3-node topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.5 GHz.
-        - RAM Memory: 16* 16GB DDR4-2666MHz.
-        - Disks: 2* 1.6TB 6G SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
-            - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
-            - PCIe Slot9 5e:00.xx: empty.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
-            - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-17. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
-    - Quantity: 8.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node or 3-node testbed topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-740GP-TNRT.
-        - Motherboard: Super X12DPG-QT6.
-        - Processors: 2* Intel Platinum 8358 2.6 GHz.
-        - RAM Memory: 16* 16GB DDR4-3200.
-        - Disks: 2* 960GB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe4.0 lanes)
-            - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
-            - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
-            - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
-        - Numa1: (x16, x16, x16 PCIe4.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: empty.
-18. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
-    - Quantity: 3.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node testbed topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-740GP-TNRT.
-        - Motherboard: Super X12DPG-QT6.
-        - Processors: 2* Intel Platinum 8358 2.6 GHz.
-        - RAM Memory: 16* 16GB DDR4-3200.
-        - Disks: 2* 960GB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe4.0 lanes)
-            - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
-            - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
-            - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
-        - Numa1: (x16, x16, x16 PCIe4.0 lanes)
-            - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: empty.
-19. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
-    - Quantity: 3.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 3-node testbed topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-740GP-TNRT.
-        - Motherboard: Super X12DPG-QT6.
-        - Processors: 2* Intel Platinum 8358 2.6 GHz.
-        - RAM Memory: 16* 16GB DDR4-3200.
-        - Disks: 2* 960GB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe4.0 lanes)
-            - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
-            - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
-            - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
-        - Numa1: (x16, x16, x16 PCIe4.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: empty.
-20. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
-    - Quantity: 3.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node and/or 3-node testbed topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-740GP-TNRT.
-        - Motherboard: Super X12DPG-QT6.
-        - Processors: 2* Intel Platinum 8358 2.6 GHz.
-        - RAM Memory: 16* 16GB DDR4-3200.
-        - Disks: 2* 960GB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe4.0 lanes)
-            - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
-            - PCIe Slot4 3b:00.xx: empty.
-            - PCIe Slot9 5e:00.xx: empty.
-        - Numa1: (x16, x16, x16 PCIe4.0 lanes)
-            - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
-            - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
-            - PCIe Slot10 d8:00.xx: empty.
-21. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
-    - Quantity: 2
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 3-node testbed topology.
-    - Main HW configuration:
-        - Chassis: Intel JACOBSVILLE SDP.
-        - Motherboard: Intel JACOBSVILLE E63448-400.
-        - Processors: 1* Intel Atom P5362B 2.2 GHz.
-        - RAM Memory: 2* 16GB DDR4-2933.
-        - Disks: ?* ? SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, PCIe3.0 lane)
-            - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
-22. Server-Type-H1: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
-    - Quantity: 1.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 3-numa-node testbed topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-741GE-TNRT.
-        - Motherboard: Super X13DEG-QT-P.
-        - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
-        - RAM Memory: 16* 32GB DDR5-4800.
-        - Disks: 2* 960GB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe5.0 lanes)
-            - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-            - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-            - PCIe Slot9 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-        - Numa1: (x16, x16, x16 PCIe5.0 lanes)
-            - PCIe Slot6 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-            - PCIe Slot8 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-            - PCIe Slot10 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-23. TODO-REVIEW Server-Type-H2: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
-    - Quantity: 1.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 3-numa-node testbed topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-741GE-TNRT.
-        - Motherboard: Super X13DEG-QT-P.
-        - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
-        - RAM Memory: 16* 32GB DDR5-4800.
-        - Disks: 2* 960GB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe5.0 lanes)
-            - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-            - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-            - PCIe Slot9 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-        - Numa1: (x16, x16, x16 PCIe5.0 lanes)
-            - PCIe Slot6 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-            - PCIe Slot8 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-            - PCIe Slot10 d8:00.xx: empty.
-24. Server-Type-H3: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
-    - Quantity: 1.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 3-numa-node testbed topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-741GE-TNRT.
-        - Motherboard: Super X13DEG-QT-P.
-        - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
-        - RAM Memory: 16* 32GB DDR5-4800.
-        - Disks: 2* 960GB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe5.0 lanes)
-            - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
-            - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
-            - PCIe Slot9 5e:00.xx: 
-        - Numa1: (x16, x16, x16 PCIe5.0 lanes)
-            - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
-            - PCIe Slot8 af:00.xx: e810-XXVDA4-4p25GE Intel.
-            - PCIe Slot10 d8:00.xx: empty.
-25. Server-Type-H4: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
-    - Quantity: 1.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 3-numa-node testbed topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-741GE-TNRT.
-        - Motherboard: Super X13DEG-QT-P.
-        - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
-        - RAM Memory: 16* 32GB DDR5-4800.
-        - Disks: 2* 960GB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe5.0 lanes)
-            - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
-            - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
-            - PCIe Slot9 5e:00.xx: empty.
-        - Numa1: (x16, x16, x16 PCIe5.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: empty.
-26. Server-Type-H5: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
-    - Quantity: 2.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node testbed topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-741GE-TNRT.
-        - Motherboard: Super X13DEG-QT-P.
-        - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
-        - RAM Memory: 16* 32GB DDR5-4800.
-        - Disks: 2* 960GB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe5.0 lanes)
-            - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-            - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
-            - PCIe Slot9 5e:00.xx: e810-XXVDA4-4p25GE Intel.
-        - Numa1: (x16, x16, x16 PCIe5.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
-            - PCIe Slot10 d8:00.xx: empty.
-27. Server-Type-H6: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
-    - Quantity: 2.
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-741GE-TNRT.
-        - Motherboard: Super X13DEG-QT-P.
-        - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
-        - RAM Memory: 16* 32GB DDR5-4800.
-        - Disks: 2* 960GB SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe5.0 lanes)
-            - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-            - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
-            - PCIe Slot9 5e:00.xx: e810-XXVDA4-4p25GE Intel.
-        - Numa1: (x16, x16, x16 PCIe5.0 lanes)
-            - PCIe Slot6 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
-            - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
-            - PCIe Slot10 d8:00.xx: empty.
-```
-
-### Naming Convention
-
-Following naming convention is used within this page to specify physical
-connectivity and wiring across defined CSIT testbeds:
-
-```
-- testbedname: testbedN.
-- hostname:
-    - traffic-generator: tN-tgW.
-    - system-under-testX: tN-sutX.
-- portnames:
-    - tN-tgW-cY/pZ.
-    - tN-sutX-cY/pZ.
-- where:
-    - N - testbed number.
-    - tgW - server acts as traffic-generator with W index.
-    - sutX - server acts as system-under-test with X index.
-    - Y - PCIe slot number denoting a NIC card number within the host.
-    - Z - port number on the NIC card.
-```
-
-## Testbeds Configuration
-
-### Per Testbed Server Allocation and Naming
-
-#### 1-Node-Skylake Servers (1n-skx) PROD
-
-```
-- SUT [Server-Type-B6]:
-    - testbedname: testbed11.
-    - hostname: s1-t11-sut1.
-    - IPMI IP: 10.30.50.47
-    - Host IP: 10.30.51.50
-    - portnames:
-        - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
-        - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
-        - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
-        - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-- SUT [Server-Type-B6]:
-    - testbedname: testbed12.
-    - hostname: s2-t12-sut1.
-    - IPMI IP: 10.30.50.48
-    - Host IP: 10.30.51.51
-    - portnames:
-        - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
-        - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
-        - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
-        - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 1-Node-ThunderX2 Servers (1n-tx2) PROD
-
-```
-- SUT [Server-Type-E11]:
-    - testbedname: testbed13
-    - hostname: s55-t13-sut1
-    - IPMI IP: 10.30.50.70
-    - Host IP: 10.30.51.70
-    - portnames:
-        - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-        - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
-        - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
-        - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-        - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
-        - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
-- SUT [Server-Type-E11]:
-    - testbedname: testbed14
-    - hostname: s56-t14-sut1
-    - IPMI IP: 10.30.50.71
-    - Host IP: 10.30.51.71
-    - portnames:
-        - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-        - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
-        - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
-        - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-        - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
-        - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
-```
-
-#### 1-Node-Cascadelake Servers (1n-clx) PROD
-
-```
-- SUT [Server-Type-C1]:
-    - testbedname: testbed11.
-    - hostname: s32-t14-sut1.
-    - IPMI IP: 10.30.55.17
-    - Host IP: 10.32.8.17
-    - portnames:
-        - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
-        - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
-        - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
-        - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
-
-```
-- SUT [Server-Type-B8]:
-    - testbedname: testbed25.
-    - hostname: s25-t25-sut1.
-    - IPMI IP: 10.30.50.58
-    - Host IP: 10.30.51.61
-    - portnames:
-        - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-- TG [Server-Type-B7]:
-    - testbedname: testbed25.
-    - hostname: s26-t25-tg1.
-    - IPMI IP: 10.30.50.59
-    - Host IP: 10.30.51.62
-    - portnames:
-        - s26-t25-tg1-p1 - 10GE-port1.
-        - s26-t25-tg1-p2 - 10GE-port2.
-        - s26-t25-tg1-p3 - 10GE-port3.
-        - s26-t25-tg1-p4 - 10GE-port4.
-```
-
-#### 2-Node-Cascadelake Servers (2n-clx) PROD
-
-```
-- SUT [Server-Type-C2]:
-    - testbedname: testbed27.
-    - hostname: s33-t27-sut1.
-    - IPMI IP: 10.30.55.18
-    - Host IP: 10.32.8.18
-    - portnames:
-        - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
-        - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
-        - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-C3]:
-    - testbedname: testbed27.
-    - hostname: s34-t27-tg1.
-    - IPMI IP: 10.30.55.19
-    - Host IP: 10.32.8.19
-    - portnames:
-        - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
-        - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
-        - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- SUT [Server-Type-C2]:
-    - testbedname: testbed28.
-    - hostname: s35-t28-sut1.
-    - IPMI IP: 10.30.55.20
-    - Host IP: 10.32.8.20
-    - portnames:
-        - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
-        - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
-        - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-C3]:
-    - testbedname: testbed28.
-    - hostname: s36-t28-tg1.
-    - IPMI IP: 10.30.55.21
-    - Host IP: 10.32.8.21
-    - portnames:
-        - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
-        - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
-        - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- SUT [Server-Type-C2]:
-    - testbedname: testbed29.
-    - hostname: s37-t29-sut1.
-    - IPMI IP: 10.30.55.22
-    - Host IP: 10.32.8.22
-    - portnames:
-        - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
-        - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
-        - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-C3]:
-    - testbedname: testbed29.
-    - hostname: s38-t29-tg1.
-    - IPMI IP: 10.30.55.23
-    - Host IP: 10.32.8.23
-    - portnames:
-        - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
-        - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
-```
-
-#### 2-Node-Zen2 Servers (2n-zn2) PROD
-
-```
-- SUT [Server-Type-D1]:
-    - testbedname: testbed210.
-    - hostname: s60-t210-sut1.
-    - IPMI IP: 10.30.55.24
-    - Host IP: 10.32.8.24
-    - portnames:
-        - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
-        - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
-        - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
-        - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
-        - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
-- TG [Server-Type-D2]:
-    - testbedname: testbed210.
-    - hostname: s61-t210-tg1.
-    - IPMI IP: 10.30.55.25
-    - Host IP: 10.32.8.25
-    - portnames:
-        - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
-        - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
-        - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-```
-
-#### 2-Node-ThunderX2 Servers (2x-tx2) PROD
-
-Note: Server19 (TG) is shared between testbed33 & testbed211
-
-```
-- SUT [Server-Type-E22]:
-    - testbedname: testbed211.
-    - hostname: s27-t211-sut1.
-    - IPMI IP: 10.30.50.69
-    - Host IP: 10.30.51.69
-    - portnames:
-        - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-- TG [Server-Type-E31]:
-    - testbedname: testbed33 and testbed211.
-    - hostname: s19-t33t211-tg1.
-    - IPMI IP: 10.30.50.46
-    - Host IP: 10.30.51.49
-    - portnames:
-        - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
-        - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
-        - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 2-Node-Icelake Servers (2n-icx) PROD
-
-```
-- SUT [Server-Type-F1]:
-    - testbedname: testbed212.
-    - hostname: s71-t212-sut1.
-    - IPMI IP: 10.30.51.81
-    - Host IP: 10.30.50.81
-    - portnames:
-        - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- TG [Server-Type-F2]:
-    - testbedname: testbed212.
-    - hostname: s72-t212-tg1.
-    - IPMI IP: 10.30.51.82
-    - Host IP: 10.30.50.82
-    - portnames:
-        - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-        - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- SUT [Server-Type-F1]:
-    - testbedname: testbed213.
-    - hostname: s83-t213-sut1.
-    - IPMI IP: 10.30.51.83
-    - Host IP: 10.30.50.83
-    - portnames:
-        - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- TG [Server-Type-F2]:
-    - testbedname: testbed213.
-    - hostname: s84-t213-tg1.
-    - IPMI IP: 10.30.51.84
-    - Host IP: 10.30.50.84
-    - portnames:
-        - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-        - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- SUT [Server-Type-F1]:
-    - testbedname: testbed214.
-    - hostname: s85-t214-sut1.
-    - IPMI IP: 10.30.51.85
-    - Host IP: 10.30.50.85
-    - portnames:
-        - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- TG [Server-Type-F2]:
-    - testbedname: testbed214.
-    - hostname: s86-t214-tg1.
-    - IPMI IP: 10.30.51.86
-    - Host IP: 10.30.50.86
-    - portnames:
-        - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-        - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- SUT [Server-Type-F1]:
-    - testbedname: testbed215.
-    - hostname: s87-t215-sut1.
-    - IPMI IP: 10.30.51.87
-    - Host IP: 10.30.50.87
-    - portnames:
-        - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- TG [Server-Type-F2]:
-    - testbedname: testbed215.
-    - hostname: s88-t215-tg1.
-    - IPMI IP: 10.30.51.88
-    - Host IP: 10.30.50.88
-    - portnames:
-        - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-        - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-```
-
-#### 3-Node-Rangeley Servers (3n-rng) VERIFY
-
-Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
-
-```
-- ServerB22 [Server-Type-B5]:
-    - testbedname: testbed35.
-    - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
-    - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
-    - Host IP: 10.30.51.9
-    - portnames:
-        - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
-        - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
-    - 1GB ports (tbd)
-- ServerB23 [Server-Type-B5]:
-    - testbedname: testbed35.
-    - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
-    - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
-    - Host IP: 10.30.51.10
-    - portnames:
-        - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
-        - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
-    - 1GB ports (tbd)
-- ServerB24 [Server-Type-B5]:
-    - testbedname: testbed35.
-    - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
-    - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
-    - Host IP: 10.30.51.11
-    - portnames:
-        - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
-        - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
-    - 1GB ports (tbd)
-```
-
-#### 3-Node-Taishan Servers (3n-tsh) PROD
-
-Note: Server19 (TG) is shared between testbed33 & testbed211
-
-```
-- SUT [Server-Type-E21]:
-    - testbedname: testbed33.
-    - hostname: s17-t33-sut1.
-    - IPMI IP: 10.30.50.36
-    - Host IP: 10.30.51.36
-    - portnames:
-        - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
-        - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
-        - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
-        - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
-- SUT [Server-Type-E21]:
-    - testbedname: testbed33.
-    - hostname: s18-t33-sut2.
-    - IPMI IP: 10.30.50.37
-    - Host IP: 10.30.51.37
-    - portnames:
-        - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
-        - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
-        - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
-        - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
-- TG [Server-Type-E31]:
-    - testbedname: testbed33 and testbed211.
-    - hostname: s19-t33t211-tg1.
-    - IPMI IP: 10.30.50.46
-    - Host IP: 10.30.51.49
-    - portnames:
-        - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
-        - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
-        - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
-```
-
-#### 3-Node-Altra Servers (3n-alt) PROD
-
-```
-- SUT [Server-Type-E23]:
-    - testbedname: testbed34.
-    - hostname: s62-t34-sut1.
-    - IPMI IP: 10.30.50.72
-    - Host IP: 10.30.51.72
-    - portnames:
-        - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
-        - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
-- SUT [Server-Type-E23]:
-    - testbedname: testbed34.
-    - hostname: s63-t34-sut2.
-    - IPMI IP: 10.30.50.73
-    - Host IP: 10.30.51.73
-    - portnames:
-        - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
-        - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
-- TG [Server-Type-F4]:
-    - testbedname: testbed34.
-    - hostname: s64-t34-tg1.
-    - IPMI IP: 10.30.50.74
-    - Host IP: 10.30.51.74
-    - portnames:
-        - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
-        - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
-        - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-```
-
-#### 3-Node-Icelake Servers (3n-icx) PROD
-
-```
-- ServerF1 [Server-Type-F1]:
-    - testbedname: testbed37.
-    - hostname: s65-t37-sut1.
-    - IPMI IP: 10.30.50.75
-    - Host IP: 10.30.51.75
-    - portnames:
-        - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- ServerF1 [Server-Type-F1]:
-    - testbedname: testbed37.
-    - hostname: s66-t37-sut2.
-    - IPMI IP: 10.30.50.76
-    - Host IP: 10.30.51.76
-    - portnames:
-        - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- ServerF3 [Server-Type-F3]:
-    - testbedname: testbed37.
-    - hostname: s67-t37-tg1.
-    - IPMI IP: 10.30.50.77
-    - Host IP: 10.30.51.77
-    - portnames:
-        - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- ServerF1 [Server-Type-F1]:
-    - testbedname: testbed38.
-    - hostname: s78-t38-sut1.
-    - IPMI IP: 10.30.50.78
-    - Host IP: 10.30.51.78
-    - portnames:
-        - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- ServerF1 [Server-Type-F1]:
-    - testbedname: testbed38.
-    - hostname: s79-t38-sut2.
-    - IPMI IP: 10.30.50.79
-    - Host IP: 10.30.51.79
-    - portnames:
-        - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-- ServerF3 [Server-Type-F3]:
-    - testbedname: testbed38.
-    - hostname: s80-t38-tg1.
-    - IPMI IP: 10.30.50.80
-    - Host IP: 10.30.51.80
-    - portnames:
-        - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-        - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
-        - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
-```
-
-#### 3-Node-SnowRidge Servers (3n-snr) PROD
-
-```
-- ServerG1 [Server-Type-G1]:
-    - testbedname: testbed39.
-    - hostname: s93-t39-sut1.
-    - IPMI IP: 10.30.50.93
-    - Host IP: 10.30.51.93
-    - portnames:
-        - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
-- ServerG1 [Server-Type-G1]:
-    - testbedname: testbed39.
-    - hostname: s94-t39-sut2.
-    - IPMI IP: 10.30.50.94
-    - Host IP: 10.30.51.94
-    - portnames:
-        - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-- ServerF4 [Server-Type-F4]:
-    - testbedname: testbed39.
-    - hostname: s89-t39t310-tg1.
-    - IPMI IP: 10.30.50.89
-    - Host IP: 10.30.51.89
-    - portnames:
-        - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
-        - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
-        - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
-        - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
-```
-
-### Per Testbed Wiring
-
-#### 1-Node-Skylake Wiring (1n-skx) PROD
-
-```
-- testbed11:
-    - ring1 10GE-ports x710-4p10GE:
-        - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
-    - ring2 10GE-ports x710-4p10GE:
-        - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
-    - ring3 10GE-ports x710-4p10GE:
-        - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
-    - ring4 10GE-ports x710-4p10GE:
-        - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
-    - ring5 100GE-ports e810-2p100GE:
-        - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
-    - ring6 100GE-ports e810-2p100GE:
-        - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
-- testbed12:
-    - ring1 10GE-ports x710-4p10GE:
-        - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
-    - ring2 10GE-ports x710-4p10GE:
-        - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
-    - ring3 10GE-ports x710-4p10GE:
-        - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
-    - ring4 10GE-ports x710-4p10GE:
-        - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
-    - ring5 100GE-ports e810-2p100GE:
-        - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
-    - ring6 100GE-ports e810-2p100GE:
-        - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
-```
-
-#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
-
-```
-- testbed13:
-    - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
-        - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
-    - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
-        - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
-    - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
-        - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
-    - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
-        - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
-
-- testbed14:
-    - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
-        - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
-    - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
-        - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
-    - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
-        - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
-    - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
-        - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
-```
-
-#### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
-
-```
-- testbed25:
-    - link1 10GE-port x710-4p10GE on SUT:
-        - t25-tg1-p1 to t25-sut1-c2/p1.
-    - link2 10GE-port x710-4p10GE on SUT:
-        - t25-tg1-p2 to t25-sut1-c2/p2.
-    - link3 10GE-port x710-4p10GE on SUT:
-        - t25-tg1-p3 to t25-sut1-c2/p3.
-    - link4 10GE-port x710-4p10GE on SUT:
-        - t25-tg1-p4 to t25-sut1-c2/p4.
-```
-
-#### 2-Node-Cascadelake Wiring (2n-clx) PROD
-
-```
-- testbed27:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
-        - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
-        - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
-        - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
-    - ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
-        - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
-    - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
-        - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
-        - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
-    - ring6 100GE-ports e810-2p100GE on TG:
-        - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
-        - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
-- testbed28:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
-        - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
-        - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
-        - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
-    - ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
-        - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
-    - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
-        - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
-        - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
-    - ring6 100GE-ports e810-2p100GE on TG:
-        - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
-        - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
-- testbed29:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
-        - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
-        - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
-        - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
-    - ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
-        - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
-    - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
-        - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
-        - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
-```
-
-#### 2-Node-Zen2 Wiring (2n-zn2) PROD
-
-```
-- testbed210:
-    - ring1 10GE-ports x710-4p10GE on SUT:
-        - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
-        - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
-    - ring2 10GE-ports x710-4p10GE on SUT:
-        - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
-        - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
-    - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
-        - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
-    - ring4 100GE-ports ConnectX5-2p100GE on SUT:
-        - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
-        - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
-```
-
-#### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
-
-```
-- testbed211:
-    - ring1 10GE-ports x520-2p10GE on SUTs:
-        - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
-        - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
-```
-
-#### 2-Node-Icelake Wiring (2n-icx) PROD
-
-```
-- testbed212:
-    - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
-        - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
-    - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
-        - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
-        - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
-        - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
-        - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
-    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
-        - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
-        - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
-    - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
-        - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
-        - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
-- testbed213:
-    - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
-        - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
-    - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
-        - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
-        - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
-        - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
-        - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
-    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
-        - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
-        - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
-    - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
-        - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
-        - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
-- testbed214:
-    - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
-        - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
-    - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
-        - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
-        - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
-        - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
-        - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
-    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
-        - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
-        - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
-    - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
-        - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
-        - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
-- testbed215:
-    - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
-        - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
-        - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
-    - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
-        - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
-        - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
-        - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
-        - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
-    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
-        - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
-        - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
-    - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
-        - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
-        - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
-```
-
-#### 3-Node-Rangeley Wiring (3n-rng) VERIFY
-
-```
-To be completed.
-```
-
-#### 3-Node-Taishan Wiring (3n-tsh) PROD
-
-```
-- testbed33:
-    - ring1 10GE-ports x520-2p10GE on SUTs:
-        - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
-        - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
-        - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
-    - ring2 25GE-ports cx4-2p25GE on SUTs:
-        - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
-        - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
-        - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
-```
-
-#### 3-Node-Altra Wiring (3n-alt) PROD
-
-```
-- testbed34:
-    - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
-        - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
-        - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
-        - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
-```
-
-#### 3-Node-Icelake Wiring (3n-icx) PROD
-
-```
-- testbed37:
-    - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
-        - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
-        - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
-        - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
-    - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
-        - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
-        - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
-        - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
-        - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
-        - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
-        - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
-    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
-        - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
-        - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
-        - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
-- testbed38:
-    - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
-        - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
-        - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
-        - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
-    - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
-        - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
-        - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
-        - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
-        - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
-        - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
-        - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
-    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
-        - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
-        - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
-        - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
-```
-
-#### 3-Node-SnowRidge Wiring (3n-snr) PROD
-
-```
-- testbed39:
-    - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
-        - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
-        - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
-        - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
-        - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
-        - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
-        - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
-```
-
-## Inventory
-
-### Appliances
-
-```
-1. Ixia PerfectStorm One Appliance
-    - 1 * PS10GE4NG
-        - Chassis: PS10GE4NG.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: Quad-Core, Intel Processor.
-        - HW accelerators: FPGA offload.
-        - RAM Memory: 64GB.
-        - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
-        - Physical Interfaces: 4 * 10GE SFP+.
-        - Operating System: Native IxOS.
-```
-
-### Arm Servers
-
-```
-1. Arm Cortex A-72 servers
-    - 2 * ThunderX2 (VPP Device)
-        - Chassis: GIGABYTE Rack Mount
-        - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
-        - RAM Memory: 16* 16GB DIMM
-        - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
-    - 1 * ThunderX2 (Performance)
-        - Chassis: GIGABYTE Rack Mount
-        - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
-        - RAM Memory: 4* 32GB RDIMM
-        - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
-    - 2 * Huawei TaiShan 2280.
-        - Chassis: Huawei TaiShan 2280.
-        - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
-        - RAM Memory: 8* 16GB DDR4-2400MT/s.
-        - Disks: 1* 4TB SATA HDD.
-2. Arm Neoverse N1 servers
-    - 2 * Ampere Altra (Performance)
-        - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
-        - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
-        - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
-        - RAM Memory: 16* 8GB DDR4-3200MT/s
-        - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
-    - 2 * Ampere Altra (Build)
-        - Chassis: Gigabyte R152-P30-00 1U
-        - Motherboard: MP32-AR1-00
-        - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
-        - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
-        - RAM Memory: 12* 16GB DDR4-3200MT/s
-        - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
-```
-
-### Xeon and Atom Servers
-
-```
-1. Intel Xeon servers:
-    - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.5 GHz.
-        - RAM Memory: 16* 16GB DDR4-2666MHz.
-        - Disks: 2* 1.6TB 6G SATA SSD.
-2. Intel Atom servers with Rangely processors.
-    - 3 * Netgate XG-2758-1u
-        - Chassis: Netgate XG-2758-1u
-        - Processors: 1* Rangely (Atom) C2758 2.4 GHz
-        - RAM Memory: 16GB ECC
-        - Disks: 150 GB
-```
-
-### Network Interface Cards
-
-```
-1. 10GE NICs
-    - ?
-2. 25GE NICs
-    - ?
-3. 40GE NICs
-    - ?
-4. 100GE NICs
-    - ?
-```
-
-### Pluggables and Cables
-
-Pluggables:
-
-```
-1. 10GE SFP+
-    - ?
-2. 25GE SFP28
-    - ?
-3. 40GE QSFP+
-    - ?
-4. 100GE
-    - ?
-```
-
-Standalone cables:
-
-```
-1. 10GE
-    - ?
-2. 25GE
-    - ?
-3. 40GE QSFP+
-    - ?
-4. 100GE
-    - ?
-```
-
-### Other Parts
-
-None.