+Naming Convention\r
+-----------------\r
+\r
+Following naming convention is used within this page to specify physical\r
+connectivity and wiring across defined CSIT testbeds:\r
+\r
+- testbedname: testbedN.\r
+- hostname:\r
+\r
+ - traffic-generator: tN-tgW.\r
+ - system-under-testX: tN-sutX.\r
+\r
+- portnames:\r
+\r
+ - tN-tgW-cY/pZ.\r
+ - tN-sutX-cY/pZ.\r
+\r
+- where:\r
+\r
+ - N - testbed number.\r
+ - tgW - server acts as traffic-generator with W index.\r
+ - sutX - server acts as system-under-test with X index.\r
+ - Y - PCIe slot number denoting a NIC card number within the host.\r
+\r
+ - Y=1,2,3 - slots in Riser 1, Right PCIe Riser Board, NUMA node 0.\r
+ - Y=4,5,6 - slots in Riser 2, Left PCIe Riser Board, NUMA node 1.\r
+ - Y=m - the MLOM slot.\r
+\r
+ - Z - port number on the NIC card.\r
+\r
+Server HW Configuration\r
+-----------------------\r
+\r
+CSIT testbed contains following three HW configuration types of UCS x86 servers,\r
+across total of ten servers provided:\r
+\r
+#. Type-1: Purpose - VPP functional and performance conformance testing.\r
+\r
+ - Quantity: 6 computers as SUT hosts (Systems Under Test).\r
+ - Physical connectivity:\r
+\r
+ - CIMC and host management ports.\r
+ - NIC ports connected in 3-node topologies.\r
+\r
+ - Main HW configuration:\r
+\r
+ - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.\r
+ - Processors: 2* E5-2699 2.3 GHz.\r
+ - RAM Memory: 16* 32GB DDR4-2133MHz.\r
+ - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.\r
+\r
+ - NICs configuration:\r
+\r
+ - Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)\r
+\r
+ - PCIe Slot1: Cisco VIC 1385 2p40GE.\r
+\r
+ - PCIe Slot2: Intel NIC x520 2p10GE.\r
+ - PCIe Slot3: empty.\r
+\r
+ - Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)\r
+\r
+ - PCIe Slot4: Intel NIC xl710 2p40GE.\r
+ - PCIe Slot5: Intel NIC x710 2p10GE.\r
+ - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)\r
+\r
+ - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).\r
+\r
+#. Type-2: Purpose - VPP functional and performance conformance testing.\r
+\r
+ - Quantity: 3 computers as TG hosts (Traffic Generators).\r
+ - Physical connectivity:\r
+\r
+ - CIMC and host management ports.\r
+ - NIC ports connected in 3-node topologies.\r
+\r
+ - Main HW configuration:\r
+\r
+ - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.\r
+ - Processors: 2* E5-2699 2.3 GHz.\r
+ - RAM Memory: 16* 32GB DDR4-2133MHz.\r
+ - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.\r
+\r
+ - NICs configuration:\r
+\r
+ - Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)\r
+\r
+ - PCIe Slot1: Intel NIC xl710 2p40GE.\r
+ - PCIe Slot2: Intel NIC x710 2p10GE.\r
+ - PCIe Slot3: Intel NIC x710 2p10GE.\r
+\r
+ - Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)\r
+\r
+ - PCIe Slot4: Intel NIC xl710 2p40GE.\r
+ - PCIe Slot5: Intel NIC x710 2p10GE.\r
+ - PCIe Slot6: Intel NIC x710 2p10GE.\r
+\r
+ - MLOM slot: empty.\r
+\r
+#. Type-3: Purpose - VIRL functional conformance.\r
+\r
+ - Quantity: 3 computers as VIRL hosts.\r
+ - Physical connectivity:\r
+\r
+ - CIMC and host management ports.\r
+ - no NIC ports, standalone setup.\r
+\r
+ - Main HW configuration:\r
+\r
+ - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.\r
+ - Processors: 2* E5-2699 2.3 GHz.\r
+ - RAM Memory: 16* 32GB DDR4-2133MHz.\r
+ - Disks: 2* 480 GB 2.5inch 6G SATA SSD.\r
+\r
+ - NICs configuration:\r
+\r
+ - Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)\r
+\r
+ - no cards.\r
+\r
+ - Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)\r
+\r
+ - no cards.\r
+\r
+ - MLOM slot: empty.\r
+\r