-+---+--------------------------------------------+------------+----------------------------------------------------------------------------+\r
-| # | Issue | Jira ID | Description |\r
-+---+--------------------------------------------+------------+----------------------------------------------------------------------------+\r
-| 1 | IP address subnet validation | VPP-649 | When configuring two IP addresses from the same subnet on an interface, |\r
-| | | | VPP refuses the configuration but returns OK. This can cause desync |\r
-| | | | between Honeycomb's config and operational data. |\r
-+---+--------------------------------------------+------------+----------------------------------------------------------------------------+\r
-| 2 | Persistence of VxLAN tunnel naming context | HC2VPP-47 | When VPP restarts with Honeycomb running and a VxLan interface configured, |\r
-| | | | the interface is sometimes renamed to "vxlan_tunnel0". |\r
-| | | | It is otherwise configured correctly. |\r
-+---+--------------------------------------------+------------+----------------------------------------------------------------------------+\r
-| 3 | Classifier plugin for IPv6 cases | VPP-687 | Classifier ignores IPv6 packets with less than 8 bytes after last header. |\r
-| | | | Fixed in VPP 17.07. |\r
-+---+--------------------------------------------+------------+----------------------------------------------------------------------------+\r
-| 4 | Batch disable Lisp features | HC2VPP-131 | When removing complex Lisp configurations in a single request, |\r
-| | | | the operation fails due to a write ordering issue. |\r
-+---+--------------------------------------------+------------+----------------------------------------------------------------------------+\r
-\r