+(B)MRR Throughput
+-----------------
+
+Maximum Receive Rate (MRR) tests are complementary to MLRsearch tests,
+as they provide a maximum "raw" throughput benchmark for development and
+testing community. MRR tests measure the packet forwarding rate under
+the maximum load offered by traffic generator over a set trial duration,
+regardless of packet loss. Maximum load for specified Ethernet frame
+size is set to the bi-directional link rate.
+
+In |csit-release| MRR test code has been updated with a configurable
+burst MRR parameters: trial duration and number of trials in a single
+burst. This enabled a new Burst MRR (BMRR) methodology for more precise
+performance trending.
+
+Current parameters for BMRR tests:
+
+- Ethernet frame sizes: 64B (78B for IPv6), IMIX, 1518B, 9000B; all
+  quoted sizes include frame CRC, but exclude per frame transmission
+  overhead of 20B (preamble, inter frame gap).
+
+- Maximum load offered: 10GE and 40GE link (sub-)rates depending on NIC
+  tested, with the actual packet rate depending on frame size,
+  transmission overhead and traffic generator NIC forwarding capacity.
+
+  - For 10GE NICs the maximum packet rate load is 2* 14.88 Mpps for 64B,
+    a 10GE bi-directional link rate.
+  - For 25GE NICs the maximum packet rate load is 2* 18.75 Mpps for 64B,
+    a 25GE bi-directional link sub-rate limited by TG 25GE NIC used,
+    XXV710.
+  - For 40GE NICs the maximum packet rate load is 2* 18.75 Mpps for 64B,
+    a 40GE bi-directional link sub-rate limited by TG 40GE NIC used,
+    XL710. Packet rate for other tested frame sizes is limited by PCIe
+    Gen3 x8 bandwidth limitation of ~50Gbps.
+
+- Trial duration: 1 sec.
+
+- Number of trials per burst: 10.
+
+Similarly to NDR/PDR throughput tests, MRR test should be reporting bi-
+directional link rate (or NIC rate, if lower) if tested VPP
+configuration can handle the packet rate higher than bi-directional link
+rate, e.g. large packet tests and/or multi-core tests.
+
+MRR tests are currently used for FD.io CSIT continuous performance
+trending and for comparison between releases. Daily trending job tests
+subset of frame sizes, focusing on 64B (78B for IPv6) for all tests and
+IMIX for selected tests (vhost, memif).
+
+MRR-like measurements are being used to establish starting conditions
+for experimental Probabilistic Loss Ratio Search (PLRsearch) used for
+soak testing, aimed at verifying continuous system performance over an
+extended period of time, hours, days, weeks, months. PLRsearch code is
+currently in experimental phase in FD.io CSIT project.