Report: update 3n-alt TG NICs and add picture
[csit.git] / docs / report / introduction / physical_testbeds.rst
index 60b06e6..d265efd 100644 (file)
@@ -26,18 +26,11 @@ Two physical server topology types are used:
 Current FD.io production testbeds are built with SUT servers based on
 the following processor architectures:
 
 Current FD.io production testbeds are built with SUT servers based on
 the following processor architectures:
 
-- Intel Xeon: Skylake Platinum 8180, Cascadelake 6252N, (Icelake 8358
-  to be added).
+- Intel Xeon: Skylake Platinum 8180, Cascadelake 6252N, Icelake 8358.
 - Intel Atom: Denverton C3858.
 - Arm: TaiShan 2280, hip07-d05.
 - AMD EPYC: Zen2 7532.
 
 - Intel Atom: Denverton C3858.
 - Arm: TaiShan 2280, hip07-d05.
 - AMD EPYC: Zen2 7532.
 
-CSIT-2106 report data for Intel Xeon Icelake testbeds comes from
-testbeds in Intel labs set up per CSIT specification and running CSIT
-code. Physical setup used is specified in 2n-icx and 3n-icx sections
-below. For details about tested VPP and CSIT versions
-see :ref:`vpp_performance_tests_release_notes`.
-
 Server SUT performance depends on server and processor type, hence
 results for testbeds based on different servers must be reported
 separately, and compared if appropriate.
 Server SUT performance depends on server and processor type, hence
 results for testbeds based on different servers must be reported
 separately, and compared if appropriate.
@@ -53,7 +46,7 @@ SUT and TG servers are equipped with a number of different NIC models.
 
 VPP is performance tested on SUTs with the following NICs and drivers:
 
 
 VPP is performance tested on SUTs with the following NICs and drivers:
 
-#. 2p10GE: x520, x550, x553 Intel (codename Niantic)
+#. 2p10GE: x550, x553 Intel (codename Niantic)
    - DPDK Poll Mode Driver (PMD).
 #. 4p10GE: x710-DA4 Intel (codename Fortville, FVL)
    - DPDK PMD.
    - DPDK Poll Mode Driver (PMD).
 #. 4p10GE: x710-DA4 Intel (codename Fortville, FVL)
    - DPDK PMD.
@@ -121,7 +114,7 @@ All AMD EPYC Zen2 7532 servers run with AMD SMT enabled, doubling the
 number of logical cores exposed to Linux.
 
 2-Node Xeon Cascadelake (2n-clx)
 number of logical cores exposed to Linux.
 
 2-Node Xeon Cascadelake (2n-clx)
----------------------------------
+--------------------------------
 
 Three 2n-clx testbeds are in operation in FD.io labs. Each 2n-clx testbed
 is built with two SuperMicro SYS-7049GP-TRT servers, SUTs are equipped with two
 
 Three 2n-clx testbeds are in operation in FD.io labs. Each 2n-clx testbed
 is built with two SuperMicro SYS-7049GP-TRT servers, SUTs are equipped with two
@@ -167,15 +160,14 @@ TG NICs:
 All Intel Xeon Cascadelake servers run with Intel Hyper-Threading enabled,
 doubling the number of logical cores exposed to Linux.
 
 All Intel Xeon Cascadelake servers run with Intel Hyper-Threading enabled,
 doubling the number of logical cores exposed to Linux.
 
-2-Node Xeon Icelake (2n-icx) EXPERIMENTAL
------------------------------------------
+.. _physical_testbeds_2n_icx:
+
+2-Node Xeon Icelake (2n-icx)
+----------------------------
 
 
-One 2n-icx testbed located in Intel labs was used for CSIT testing. It
-is built with two SuperMicro SYS-740GP-TNRT servers. SUT is equipped
-with two Intel Xeon Gold 6338N processors (48 MB Cache, 2.20 GHz, 32
-cores). TG is equiped with two Intel Xeon Ice Lake Platinum 8360Y
-processors (54 MB Cache, 2.40 GHz, 36 cores). 2n-icx physical topology
-is shown below.
+One 2n-icx testbed is in operation in FD.io labs. It is built with two
+SuperMicro SYS-740GP-TNRT servers, each in turn equipped with two Intel Xeon
+Platinum 8358 processors (48 MB Cache, 2.60 GHz, 32 cores).
 
 .. only:: latex
 
 
 .. only:: latex
 
@@ -196,20 +188,21 @@ is shown below.
 
 SUT and TG NICs:
 
 
 SUT and TG NICs:
 
-#. NIC-1: E810-2CQDA2 2p100GbE Intel.
+#. NIC-1: xxv710-DA2 2p25GE Intel.
+#. NIC-2: E810-2CQDA2 2p100GbE Intel (* to be added).
+#. NIC-3: E810-CQDA4 4p100GbE Intel (* to be added).
 
 All Intel Xeon Icelake servers run with Intel Hyper-Threading enabled,
 doubling the number of logical cores exposed to Linux.
 
 
 All Intel Xeon Icelake servers run with Intel Hyper-Threading enabled,
 doubling the number of logical cores exposed to Linux.
 
-3-Node Xeon Icelake (3n-icx) EXPERIMENTAL
------------------------------------------
+.. _physical_testbeds_3n_icx:
+
+3-Node Xeon Icelake (3n-icx)
+----------------------------
 
 
-One 3n-icx testbed located in Intel labs was used for CSIT testing. It
-is built with three SuperMicro SYS-740GP-TNRT servers. SUTs are
-equipped each with two Intel Xeon Platinum 8360Y processors (54 MB
-Cache, 2.40 GHz, 36 cores). TG is equiped with two Intel Xeon Ice Lake
-Platinum 8360Y processors (54 MB Cache, 2.40 GHz, 36 cores). 3n-icx
-physical topology is shown below.
+One 3n-icx testbed is in operation in FD.io labs. It is built with three
+SuperMicro SYS-740GP-TNRT servers, each in turn equipped with two Intel Xeon
+Platinum 8358 processors (48 MB Cache, 2.60 GHz, 32 cores).
 
 .. only:: latex
 
 
 .. only:: latex
 
@@ -230,7 +223,9 @@ physical topology is shown below.
 
 SUT and TG NICs:
 
 
 SUT and TG NICs:
 
-#. NIC-1: E810-2CQDA2 2p100GbE Intel.
+#. NIC-1: xxv710-DA2 2p25GE Intel.
+#. NIC-2: E810-2CQDA2 2p100GbE Intel (* to be added).
+#. NIC-3: E810-CQDA4 4p100GbE Intel (* to be added).
 
 All Intel Xeon Icelake servers run with Intel Hyper-Threading enabled,
 doubling the number of logical cores exposed to Linux.
 
 All Intel Xeon Icelake servers run with Intel Hyper-Threading enabled,
 doubling the number of logical cores exposed to Linux.
@@ -407,6 +402,45 @@ TG NICs:
 
 #. NIC-1: x710-DA4 4p10GE Intel.
 
 
 #. NIC-1: x710-DA4 4p10GE Intel.
 
+.. _physical_testbeds_3n_alt:
+
+3-Node ARM Altra (3n-alt)
+---------------------------
+
+One 3n-tsh testbed is built with: i) one SuperMicro SYS-740GP-TNRT
+server acting as TG and equipped with two Intel Xeon Icelake Platinum
+8358 processors (80 MB Cache, 2.60 GHz, 32 cores), and ii) one Ampere
+Altra server acting as SUT and equipped with two Q80-30 processors
+(80* ARM Neoverse N1). 3n-alt physical topology is shown below.
+
+.. only:: latex
+
+    .. raw:: latex
+
+        \begin{figure}[H]
+            \centering
+                \graphicspath{{../_tmp/src/introduction/}}
+                \includegraphics[width=0.90\textwidth]{testbed-3n-alt}
+                \label{fig:testbed-3n-alt}
+        \end{figure}
+
+.. only:: html
+
+    .. figure:: testbed-3n-alt.svg
+        :alt: testbed-3n-alt
+        :align: center
+
+SUT1 and SUT2 NICs:
+
+#. NIC-1: xl710-QDA2-2p40GE Intel.
+
+TG NICs:
+
+#. NIC-1: xxv710-DA2-2p25GE Intel.
+#. NIC-2: xl710-QDA2-2p40GE Intel.
+#. NIC-3: e810-XXVDA4-4p25GE Intel.
+#. NIC-4: e810-2CQDA2-2p100GE Intel.
+
 3-Node ARM TaiShan (3n-tsh)
 ---------------------------
 
 3-Node ARM TaiShan (3n-tsh)
 ---------------------------
 
@@ -445,7 +479,7 @@ TG NICs:
 #. NIC-3: xl710-QDA2 2p40GE Intel.
 
 2-Node ARM ThunderX2 (2n-tx2)
 #. NIC-3: xl710-QDA2 2p40GE Intel.
 
 2-Node ARM ThunderX2 (2n-tx2)
----------------------------
+-----------------------------
 
 One 2n-tx2 testbed is built with: i) one SuperMicro SYS-7049GP-TRT
 server acting as TG and equipped with two Intel Xeon Skylake Platinum
 
 One 2n-tx2 testbed is built with: i) one SuperMicro SYS-7049GP-TRT
 server acting as TG and equipped with two Intel Xeon Skylake Platinum