-#. VPP performance test environment changes\r
-\r
- - further VM and vhost-user test environment optimizations - Qemu virtio queue size increased from default value of 256 to 1024\r
- - addition of HW cryptodev devices in all three LF FD.io physical testbeds\r
-\r
-#. Added tests (to be updated)\r
-\r
- - NICs\r
-\r
- - Intel x710 (L2 Bridge Domain switched-forwarding, vhost-user)\r
- - Cisco VIC1385 (L2 Bridge Domain switched-forwarding)\r
- - Cisco VIC1227 (L2 Bridge Domain switched-forwarding)\r
-\r
- - vhost-user tests with VM\r
-\r
- - L2 Bridge Domain switched-forwarding with Intel x710 NIC\r
- - L2 Bridge Domain switched-forwarding with VxLAN and Intel x520 NIC\r
- - L2 Bridge Domain switched-forwarding with Intel xl710 NIC\r
-\r
- - Tests with VxLAN\r
-\r
- - L2 Bridge Domain switched-forwarding with Intel x520 NIC\r
- - L2 Bridge Domain switched-forwarding with vhost-user, VM and Intel x520\r
- NIC\r
-\r
-Performance Improvements - to be updated\r
-------------------------\r
-\r
-Substantial improvements in measured packet throughput, with relative increase\r
-of double-digit percentage points, have been observed in a number of CSIT\r
-|release| tests listed below. Relative improvements are calculated against the\r
-test results in CSIT rls1701 report.\r
-\r
-NDR Throughput\r
-~~~~~~~~~~~~~~\r
-\r
-Non-Drop Rate Throughput discovery tests:\r
-\r
-+-------------------+-----------------------------------------------------------------+------------+-----------+----------------------------+\r
-| VPP Functionality | Test Name | VPP-16.09 | VPP-17.01 | VPP-17.04 | 17.01 to 17.04 |\r
-| | | [Mpps] | [Mpps] | [Mpps] | Improvement |\r
-+===================+=================================================================+============+===========+===========+================+\r
-| L2XC | 10ge2p1x520: 64B-1t1c-eth-l2xcbase-ndrdisc | 9.4 | 12.7 | 13.4 | 6% |\r
-+-------------------+-----------------------------------------------------------------+------------+-----------+-----------+----------------+\r
-| L2XC | 10ge2p1xl710: 64B-1t1c-eth-l2xcbase-ndrdisc | 9.5 | 12.2 | 12.4 | 2% |\r
-+-------------------+-----------------------------------------------------------------+------------+-----------+-----------+----------------+\r
-| L2XC dot1ad | 10ge2p1x520: 64B-1t1c-dot1ad-l2xcbase-ndrdisc | 7.4 | 8.8 | 9.3 | 6% |\r
-+-------------------+-----------------------------------------------------------------+------------+-----------+-----------+----------------+\r
-| L2XC dot1q | 10ge2p1x520: 64B-1t1c-dot1q-l2xcbase-ndrdisc | 7.5 | 8.8 | 9.2 | 5% |\r
-+-------------------+-----------------------------------------------------------------+------------+-----------+-----------+----------------+\r
-| L2XC VxLAN | 10ge2p1x520: 64B-1t1c-ethip4vxlan-l2xcbase-ndrdisc | 5.4 | 6.5 | 6.8 | 5% |\r
-+-------------------+-----------------------------------------------------------------+------------+-----------+-----------+----------------+\r
-| L2XC-vhost-VM | 10ge2p1x520: 64B-1t1c-eth-l2xcbase-eth-2vhost-1vm-ndrdisc | 0.5 | 2.8 | 3.2 | 14% |\r
-+-------------------+-----------------------------------------------------------------+------------+-----------+-----------+----------------+\r
-| L2BD | 10ge2p1x520: 64B-1t1c-eth-l2bdbasemaclrn-ndrdisc | 7.8 | 10.4 | 10.8 | 4% |\r
-+-------------------+-----------------------------------------------------------------+------------+-----------+-----------+----------------+\r
-| L2BD-vhost-VM | 10ge2p1x520: 64B-1t1c-eth-l2bdbasemaclrn-eth-2vhost-1vm-ndrdisc | 0.4 | 2.7 | 3.4 | 26% |\r
-+-------------------+-----------------------------------------------------------------+------------+-----------+-----------+----------------+\r
-| IPv4 | 10ge2p1x520: 64B-1t1c-ethip4-ip4base-ndrdisc | 8.7 | 9.7 | 10.6 | 9% |\r
-+-------------------+-----------------------------------------------------------------+------------+-----------+-----------+----------------+\r
-| IPv4 COP | 10ge2p1x520: 64B-1t1c-ethip4-ip4base-copwhtlistbase-ndrdisc | 7.1 | 8.3 | 9.0 | 8% |\r
-+-------------------+-----------------------------------------------------------------+------------+-----------+-----------+----------------+\r
-| IPv4 iAcl | 10ge2p1x520: 64B-1t1c-ethip4-ip4base-iacldstbase-ndrdisc | 6.9 | 7.6 | 8.3 | 9% |\r
-+-------------------+-----------------------------------------------------------------+------------+-----------+-----------+----------------+\r
-| IPv4 vhost | 10ge2p1x520: 64B-1t1c-ethip4-ip4base-eth-2vhost-1vm-ndrdisc | 0.3 | 2.6 | 3.1 | 19% |\r
-+-------------------+-----------------------------------------------------------------+------------+-----------+-----------+----------------+\r
-| IPv6 | 10ge2p1x520: 78B-1t1c-ethip6-ip6base-ndrdisc | 3.0 | 7.3 | 8.5 | 16% |\r
-+-------------------+-----------------------------------------------------------------+------------+-----------+-----------+----------------+\r
-\r
-PDR Throughput\r
-~~~~~~~~~~~~~~\r
-\r
-Partial Drop Rate thoughput discovery tests with packet Loss Tolerance of 0.5%:\r
-\r
-+-------------------+-----------------------------------------------------------------+-----------+-----------+-------------------------+\r
-| VPP Functionality | Test Name | VPP-16.09 | VPP-17.01 | VPP-17.04 | Relative |\r
-| | | [Mpps] | [Mpps] | [Mpps] | Improvement |\r
-+===================+=================================================================+===========+===========+===========+=============+\r
-| L2XC | 10ge2p1x520: 64B-1t1c-eth-l2xcbase-pdrdisc | 9.4 | 12.7 | 13.4 | % |\r
-+-------------------+-----------------------------------------------------------------+-----------+-----------+-----------+-------------+\r
-| L2XC dot1ad | 10ge2p1x520: 64B-1t1c-dot1ad-l2xcbase-pdrdisc | 7.4 | 8.8 | 9.3 | % |\r
-+-------------------+-----------------------------------------------------------------+-----------+-----------+-----------+-------------+\r
-| L2XC dot1q | 10ge2p1x520: 64B-1t1c-dot1q-l2xcbase-pdrdisc | 7.5 | 8.8 | 9.5 | % |\r
-+-------------------+-----------------------------------------------------------------+-----------+-----------+-----------+-------------+\r
-| L2XC VxLAN | 10ge2p1x520: 64B-1t1c-ethip4vxlan-l2xcbase-pdrdisc | 5.4 | 6.5 | 6.8 | % |\r
-+-------------------+-----------------------------------------------------------------+-----------+-----------+-----------+-------------+\r
-| L2XC-vhost-VM | 10ge2p1x520: 64B-1t1c-eth-l2xcbase-eth-2vhost-1vm-pdrdisc | 2.6 | 3.2 | 3.2 | % |\r
-+-------------------+-----------------------------------------------------------------+-----------+-----------+-----------+-------------+\r
-| L2BD | 10ge2p1x520: 64B-1t1c-eth-l2bdbasemaclrn-pdrdisc | 7.8 | 10.6 | 11.1 | % |\r
-+-------------------+-----------------------------------------------------------------+-----------+-----------+-----------+-------------+\r
-| L2BD-vhost-VM | 10ge2p1x520: 64B-1t1c-eth-l2bdbasemaclrn-eth-2vhost-1vm-pdrdisc | 2.1 | 2.9 | 3.2 | % |\r
-+-------------------+-----------------------------------------------------------------+-----------+-----------+-----------+-------------+\r
-| IPv4 | 10ge2p1x520: 64B-1t1c-ethip4-ip4base-pdrdisc | 8.7 | 9.7 | 10.6 | % |\r
-+-------------------+-----------------------------------------------------------------+-----------+-----------+-----------+-------------+\r
-| IPv4 COP | 10ge2p1x520: 64B-1t1c-ethip4-ip4base-copwhtlistbase-pdrdisc | 7.1 | 8.3 | 9.2 | % |\r
-+-------------------+-----------------------------------------------------------------+-----------+-----------+-----------+-------------+\r
-| IPv4 vhost | 10ge2p1x520: 64B-1t1c-ethip4-ip4base-eth-2vhost-1vm-pdrdisc | 2.0 | 2.7 | 3.2 | % |\r
-+-------------------+-----------------------------------------------------------------+-----------+-----------+-----------+-------------+\r
+#. Added VPP performance tests\r
+\r
+ - **Container Service Chain Topologies Orchestrated by K8s with VPP Memif**\r
+\r
+ - Added tests with VPP vswitch in container connecting a number of VPP-\r
+ in-container service chain topologies with L2 Cross-Connect and L2\r
+ Bridge-Domain configurations, orchestrated by Kubernetes. Added\r
+ following forwarding topologies: i) "Parallel" with packets flowing from\r
+ NIC via VPP to container and back to VPP and NIC; ii) "Chained" (a.k.a.\r
+ "Snake") with packets flowing via VPP to container, back to VPP, to next\r
+ container, back to VPP and so on until the last container in a chain,\r
+ then back to VPP and NIC; iii) "Horizontal" with packets flowing via VPP\r
+ to container, then via "horizontal" memif to next container, and so on\r
+ until the last container, then back to VPP and NIC;\r
+\r
+ - **VPP TCP/IP stack**\r
+\r
+ - Added tests for VPP TCP/IP stack using VPP built-in HTTP server.\r
+ WRK traffic generator is used as a client-side;\r
+\r
+ - **SRv6**\r
+\r
+ - Initial SRv6 (Segment Routing IPv6) tests verifying performance of\r
+ IPv6 and SRH (Segment Routing Header) encapsulation, decapsulation,\r
+ lookups and rewrites based on configured End and End.DX6 SRv6 egress\r
+ functions;\r
+\r
+ - **IPSecSW**\r
+\r
+ - SW computed IPSec encryption with AES-GCM, CBC-SHA1 ciphers, in\r
+ combination with IPv4 routed-forwarding;\r
+\r
+#. Presentation and Analytics Layer\r
+\r
+ - Added throughput speedup analysis for multi-core and multi-thread\r
+ VPP tests into Presentation and Analytics Layer (PAL) for automated\r
+ CSIT test results analysis;\r
+\r
+#. Other changes\r
+\r
+ - **Framework optimizations**\r
+\r
+ - Ability to run CSIT framework on ARM architecture;\r
+\r
+ - Overall stability improvements;\r
+\r
+ - **NDR and PDR throughput binary search change**\r
+\r
+ - Increased binary search resolution by reducing final step from\r
+ 100kpps to 50kpps;\r
+\r
+ - **VPP plugin loaded as needed by tests**\r
+\r
+ - From this release only plugins required by tests are loaded at\r
+ VPP initialization time. Previously all plugins were loaded for\r
+ all tests;\r
+\r
+Performance Changes\r
+-------------------\r
+\r
+Relative performance changes in measured packet throughput in CSIT\r
+|release| are calculated against the results from CSIT |release-1|\r
+report. Listed mean and standard deviation values are computed based on\r
+a series of the same tests executed against respective VPP releases to\r
+verify test results repeatibility, with percentage change calculated for\r
+mean values. Note that the standard deviation is quite high for a small\r
+number of packet throughput tests, what indicates poor test results\r
+repeatability and makes the relative change of mean throughput value not\r
+fully representative for these tests. The root causes behind poor\r
+results repeatibility vary between the test cases.\r
+\r
+NDR Throughput Changes\r
+~~~~~~~~~~~~~~~~~~~~~~\r
+\r
+NDR small packet throughput changes between releases are available in a CSV and\r
+pretty ASCII formats:\r
+\r
+ - `csv format for 1t1c <../_static/vpp/performance-changes-ndr-1t1c-full.csv>`_,\r
+ - `csv format for 2t2c <../_static/vpp/performance-changes-ndr-2t2c-full.csv>`_,\r
+ - `pretty ASCII format for 1t1c <../_static/vpp/performance-changes-ndr-1t1c-full.txt>`_,\r
+ - `pretty ASCII format for 2t2c <../_static/vpp/performance-changes-ndr-2t2c-full.txt>`_.\r
+\r
+PDR Throughput Changes\r
+~~~~~~~~~~~~~~~~~~~~~~\r
+\r
+NDR small packet throughput changes between releases are available in a CSV and\r
+pretty ASCII formats:\r
+\r
+ - `csv format for 1t1c <../_static/vpp/performance-changes-pdr-1t1c-full.csv>`_,\r
+ - `csv format for 2t2c <../_static/vpp/performance-changes-pdr-2t2c-full.csv>`_,\r
+ - `pretty ASCII format for 1t1c <../_static/vpp/performance-changes-pdr-1t1c-full.txt>`_,\r
+ - `pretty ASCII format for 2t2c <../_static/vpp/performance-changes-pdr-2t2c-full.txt>`_.\r