 Overview
 ========
 
-Tested Physical Topologies
---------------------------
+For description of physical testbeds used for VPP performance tests
+please refer to :ref:`physical_testbeds`.
 
-CSIT VPP performance tests are executed on physical baremetal servers hosted by
-LF FD.io project. Testbed physical topology is shown in the figure below.
-
-::
-
-    +------------------------+           +------------------------+
-    |                        |           |                        |
-    |  +------------------+  |           |  +------------------+  |
-    |  |                  |  |           |  |                  |  |
-    |  |                  <----------------->                  |  |
-    |  |       DUT1       |  |           |  |       DUT2       |  |
-    |  +--^---------------+  |           |  +---------------^--+  |
-    |     |                  |           |                  |     |
-    |     |            SUT1  |           |  SUT2            |     |
-    +------------------------+           +------------------^-----+
-          |                                                 |
-          |                                                 |
-          |                  +-----------+                  |
-          |                  |           |                  |
-          +------------------>    TG     <------------------+
-                             |           |
-                             +-----------+
-
-SUT1 and SUT2 are two System Under Test servers (Cisco UCS C240, each with two
-Intel XEON CPUs), TG is a Traffic Generator (TG, another Cisco UCS C240, with
-two Intel XEON CPUs). SUTs run VPP SW application in Linux user-mode as a
-Device Under Test (DUT). TG runs TRex SW application as a packet Traffic
-Generator. Physical connectivity between SUTs and to TG is provided using
-different NIC models that need to be tested for performance. Currently
-installed and tested NIC models include:
-
-#. 2port10GE X520-DA2 Intel.
-#. 2port10GE X710 Intel.
-#. 2port10GE VIC1227 Cisco.
-#. 2port40GE VIC1385 Cisco.
-#. 2port40GE XL710 Intel.
-
-From SUT and DUT perspective, all performance tests involve forwarding packets
-between two physical Ethernet ports (10GE or 40GE). Due to the number of
-listed NIC models tested and available PCI slot capacity in SUT servers, in
-all of the above cases both physical ports are located on the same NIC. In
-some test cases this results in measured packet throughput being limited not
-by VPP DUT but by either the physical interface or the NIC capacity.
-
-Going forward CSIT project will be looking to add more hardware into FD.io
-performance labs to address larger scale multi-interface and multi-NIC
-performance testing scenarios.
-
-For test cases that require DUT (VPP) to communicate with VM(s) over vhost-user
-interfaces, N of VM instances are created on SUT1 and SUT2. For N=1 DUT (VPP)
-forwards packets between vhostuser and physical interfaces. For N>1 DUT (VPP) a
-logical service chain forwarding topology is created on DUT (VPP) by applying L2
-or IPv4/IPv6 configuration depending on the test suite.
-DUT (VPP) test topology with N VM instances
-is shown in the figure below including applicable packet flow thru the DUTs and
-VMs (marked in the figure with ``***``).
-
-::
-
-    +-------------------------+           +-------------------------+
-    | +---------+ +---------+ |           | +---------+ +---------+ |
-    | |  VM[1]  | |  VM[N]  | |           | |  VM[1]  | |  VM[N]  | |
-    | |  *****  | |  *****  | |           | |  *****  | |  *****  | |
-    | +--^---^--+ +--^---^--+ |           | +--^---^--+ +--^---^--+ |
-    |   *|   |*     *|   |*   |           |   *|   |*     *|   |*   |
-    | +--v---v-------v---v--+ |           | +--v---v-------v---v--+ |
-    | |  *   *       *   *  |*|***********|*|  *   *       *   *  | |
-    | |  *   *********   ***<-|-----------|->***   *********   *  | |
-    | |  *    DUT1          | |           | |       DUT2       *  | |
-    | +--^------------------+ |           | +------------------^--+ |
-    |   *|                    |           |                    |*   |
-    |   *|            SUT1    |           |  SUT2              |*   |
-    +-------------------------+           +-------------------------+
-        *|                                                     |*
-        *|                                                     |*
-        *|                    +-----------+                    |*
-        *|                    |           |                    |*
-        *+-------------------->    TG     <--------------------+*
-        **********************|           |**********************
-                              +-----------+
-
-For VM tests, packets are switched by DUT (VPP) multiple times: twice for a
-single VM, three times for two VMs, N+1 times for N VMs.
-Hence the external
-throughput rates measured by TG and listed in this report must be multiplied
-by (N+1) to represent the actual DUT aggregate packet forwarding rate.
-
-Note that reported VPP performance results are specific to the SUTs tested.
-Current LF FD.io SUTs are based on Intel XEON E5-2699v3 2.3GHz CPUs. SUTs with
-other CPUs are likely to yield different results. A good rule of thumb, that
-can be applied to estimate VPP packet thoughput for Phy-to-Phy (NIC-to-NIC,
-PCI-to-PCI) topology, is to expect the forwarding performance to be
-proportional to CPU core frequency, assuming CPU is the only limiting factor
-and all other SUT parameters equivalent to FD.io CSIT environment. The same rule
-of thumb can be also applied for Phy-to-VM-to-Phy (NIC-to-VM-to-NIC) topology,
-but due to much higher dependency on intensive memory operations and
-sensitivity to Linux kernel scheduler settings and behaviour, this estimation
-may not always yield good enough accuracy.
-
-For detailed LF FD.io test bed specification and physical topology please refer
-to `LF FDio CSIT testbed wiki page <https://wiki.fd.io/view/CSIT/CSIT_LF_testbed>`_.
+Logical Topologies
+------------------
 
-Performance Tests Coverage
---------------------------
+CSIT VPP performance tests are executed on physical testbeds described
+in :ref:`physical_testbeds`. Based on the packet path thru server SUTs,
+three distinct logical topology types are used for VPP DUT data plane
+testing:
 
-Performance tests are split into the two main categories:
-
-- Throughput discovery - discovery of packet forwarding rate using binary search
-  in accordance to RFC2544.
-
-  - NDR - discovery of Non Drop Rate packet throughput, at zero packet loss;
-    followed by one-way packet latency measurements at 10%, 50% and 100% of
-    discovered NDR throughput.
-  - PDR - discovery of Partial Drop Rate, with specified non-zero packet loss
-    currently set to 0.5%; followed by one-way packet latency measurements at
-    100% of discovered PDR throughput.
-
-- Throughput verification - verification of packet forwarding rate against
-  previously discovered throughput rate. These tests are currently done against
-  0.9 of reference NDR, with reference rates updated periodically.
-
-CSIT |release| includes following performance test suites, listed per NIC type:
-
-- 2port10GE X520-DA2 Intel
-
-  - **L2XC** - L2 Cross-Connect switched-forwarding of untagged, dot1q, dot1ad
-    VLAN tagged Ethernet frames.
-  - **L2BD** - L2 Bridge-Domain switched-forwarding of untagged Ethernet frames
-    with MAC learning; disabled MAC learning i.e. static MAC tests to be added.
-  - **IPv4** - IPv4 routed-forwarding.
-  - **IPv6** - IPv6 routed-forwarding.
-  - **IPv4 Scale** - IPv4 routed-forwarding with 20k, 200k and 2M FIB entries.
-  - **IPv6 Scale** - IPv6 routed-forwarding with 20k, 200k and 2M FIB entries.
-  - **VMs with vhost-user** - virtual topologies with 1 VM and service chains
-    of 2 VMs using vhost-user interfaces, with VPP forwarding modes incl. L2
-    Cross-Connect, L2 Bridge-Domain, VXLAN with L2BD, IPv4 routed-forwarding.
-  - **COP** - IPv4 and IPv6 routed-forwarding with COP address security.
-  - **iACL** - IPv4 and IPv6 routed-forwarding with iACL address security.
-  - **LISP** - LISP overlay tunneling for IPv4-over-IPv4, IPv6-over-IPv4,
-    IPv6-over-IPv6, IPv4-over-IPv6 in IPv4 and IPv6 routed-forwarding modes.
-  - **VXLAN** - VXLAN overlay tunnelling integration with L2XC and L2BD.
-  - **QoS Policer** - ingress packet rate measuring, marking and limiting
-    (IPv4).
-  - **CGNAT** - Carrier Grade Network Address Translation tests with varying
-    number of users and ports per user.
-
-- 2port40GE XL710 Intel
-
-  - **L2XC** - L2 Cross-Connect switched-forwarding of untagged Ethernet frames.
-  - **L2BD** - L2 Bridge-Domain switched-forwarding of untagged Ethernet frames
-    with MAC learning.
-  - **IPv4** - IPv4 routed-forwarding.
-  - **IPv6** - IPv6 routed-forwarding.
-  - **VMs with vhost-user** - virtual topologies with 1 VM and service chains
-    of 2 VMs using vhost-user interfaces, with VPP forwarding modes incl. L2
-    Cross-Connect, L2 Bridge-Domain, VXLAN with L2BD, IPv4 routed-forwarding.
-  - **IPSec** - IPSec encryption with AES-GCM, CBC-SHA1 ciphers, in combination
-    with IPv4 routed-forwarding.
-  - **IPSec+LISP** - IPSec encryption with CBC-SHA1 ciphers, in combination
-    with LISP-GPE overlay tunneling for IPv4-over-IPv4.
-
-- 2port10GE X710 Intel
-
-  - **L2BD** - L2 Bridge-Domain switched-forwarding of untagged Ethernet frames
-    with MAC learning.
-  - **VMs with vhost-user** - virtual topologies with 1 VM using vhost-user
-    interfaces, with VPP forwarding modes incl. L2 Bridge-Domain.
-
-- 2port10GE VIC1227 Cisco
-
-  - **L2BD** - L2 Bridge-Domain switched-forwarding of untagged Ethernet frames
-    with MAC learning.
-
-- 2port40GE VIC1385 Cisco
-
-  - **L2BD** - L2 Bridge-Domain switched-forwarding of untagged Ethernet frames
-     with MAC learning.
-
-Execution of performance tests takes time, especially the throughput discovery
-tests. Due to limited HW testbed resources available within FD.io labs hosted
-by Linux Foundation, the number of tests for NICs other than X520 (a.k.a.
-Niantic) has been limited to few baseline tests. Over time we expect the HW
-testbed resources to grow, and will be adding complete set of performance
-tests for all models of hardware to be executed regularly and(or)
-continuously.
+#. NIC-to-NIC switching topologies.
+#. VM service switching topologies.
+#. Container service switching topologies.
 
-Performance Tests Naming
-------------------------
+NIC-to-NIC Switching
+~~~~~~~~~~~~~~~~~~~~
 
-CSIT |release| follows a common structured naming convention for all
-performance and system functional tests, introduced in CSIT |release-1|.
+The simplest logical topology for software data plane application like
+VPP is NIC-to-NIC switching. Tested topologies for 2-Node and 3-Node
+testbeds are shown in figures below.
 
-The naming should be intuitive for majority of the tests. Complete
-description of CSIT test naming convention is provided on `CSIT test naming wiki
-<https://wiki.fd.io/view/CSIT/csit-test-naming>`_.
-
-Here few illustrative examples of the new naming usage for performance test
-suites:
-
-#. **Physical port to physical port - a.k.a. NIC-to-NIC, Phy-to-Phy, P2P**
-
-    - *PortNICConfig-WireEncapsulation-PacketForwardingFunction-
-      PacketProcessingFunction1-...-PacketProcessingFunctionN-TestType*
-    - *10ge2p1x520-dot1q-l2bdbasemaclrn-ndrdisc.robot* => 2 ports of 10GE on
-      Intel x520 NIC, dot1q tagged Ethernet, L2 bridge-domain baseline switching
-      with MAC learning, NDR throughput discovery.
-    - *10ge2p1x520-ethip4vxlan-l2bdbasemaclrn-ndrchk.robot* => 2 ports of 10GE
-      on Intel x520 NIC, IPv4 VXLAN Ethernet, L2 bridge-domain baseline
-      switching with MAC learning, NDR throughput discovery.
-    - *10ge2p1x520-ethip4-ip4base-ndrdisc.robot* => 2 ports of 10GE on Intel
-      x520 NIC, IPv4 baseline routed forwarding, NDR throughput discovery.
-    - *10ge2p1x520-ethip6-ip6scale200k-ndrdisc.robot* => 2 ports of 10GE on
-      Intel x520 NIC, IPv6 scaled up routed forwarding, NDR throughput
-      discovery.
-
-#. **Physical port to VM (or VM chain) to physical port - a.k.a. NIC2VM2NIC,
-   P2V2P, NIC2VMchain2NIC, P2V2V2P**
-
-    - *PortNICConfig-WireEncapsulation-PacketForwardingFunction-
-      PacketProcessingFunction1-...-PacketProcessingFunctionN-VirtEncapsulation-
-      VirtPortConfig-VMconfig-TestType*
-    - *10ge2p1x520-dot1q-l2bdbasemaclrn-eth-2vhost-1vm-ndrdisc.robot* => 2 ports
-      of 10GE on Intel x520 NIC, dot1q tagged Ethernet, L2 bridge-domain
-      switching to/from two vhost interfaces and one VM, NDR throughput
-      discovery.
-    - *10ge2p1x520-ethip4vxlan-l2bdbasemaclrn-eth-2vhost-1vm-ndrdisc.robot* => 2
-      ports of 10GE on Intel x520 NIC, IPv4 VXLAN Ethernet, L2 bridge-domain
-      switching to/from two vhost interfaces and one VM, NDR throughput
-      discovery.
-    - *10ge2p1x520-ethip4vxlan-l2bdbasemaclrn-eth-4vhost-2vm-ndrdisc.robot* => 2
-      ports of 10GE on Intel x520 NIC, IPv4 VXLAN Ethernet, L2 bridge-domain
-      switching to/from four vhost interfaces and two VMs, NDR throughput
-      discovery.
-
-Methodology: Multi-Thread and Multi-Core
-----------------------------------------
-
-**HyperThreading** - CSIT |release| performance tests are executed with SUT
-servers' Intel XEON CPUs configured in HyperThreading Disabled mode (BIOS
-settings). This is the simplest configuration used to establish baseline
-single-thread single-core SW packet processing and forwarding performance.
-Subsequent releases of CSIT will add performance tests with Intel
-HyperThreading Enabled (requires BIOS settings change and hard reboot).
-
-**Multi-core Test** - CSIT |release| multi-core tests are executed in the
-following VPP thread and core configurations:
-
-#. 1t1c - 1 VPP worker thread on 1 CPU physical core.
-#. 2t2c - 2 VPP worker threads on 2 CPU physical cores.
-
-Note that in quite a few test cases running VPP on 2 physical cores hits
-the tested NIC I/O bandwidth or packets-per-second limit.
-
-Methodology: Packet Throughput
-------------------------------
-
-Following values are measured and reported for packet throughput tests:
-
-- NDR binary search per RFC2544:
-
-  - Packet rate: "RATE: <aggregate packet rate in packets-per-second> pps
-    (2x <per direction packets-per-second>)"
-  - Aggregate bandwidth: "BANDWIDTH: <aggregate bandwidth in Gigabits per
-    second> Gbps (untagged)"
-
-- PDR binary search per RFC2544:
-
-  - Packet rate: "RATE: <aggregate packet rate in packets-per-second> pps (2x
-    <per direction packets-per-second>)"
-  - Aggregate bandwidth: "BANDWIDTH: <aggregate bandwidth in Gigabits per
-    second> Gbps (untagged)"
-  - Packet loss tolerance: "LOSS_ACCEPTANCE <accepted percentage of packets
-    lost at PDR rate>""
-
-- NDR and PDR are measured for the following L2 frame sizes:
-
-  - IPv4: 64B, IMIX_v4_1 (28x64B,16x570B,4x1518B), 1518B, 9000B.
-  - IPv6: 78B, 1518B, 9000B.
-
-
-Methodology: Packet Latency
----------------------------
-
-TRex Traffic Generator (TG) is used for measuring latency of VPP DUTs. Reported
-latency values are measured using following methodology:
-
-- Latency tests are performed at 10%, 50% of discovered NDR rate (non drop rate)
-  for each NDR throughput test and packet size (except IMIX).
-- TG sends dedicated latency streams, one per direction, each at the rate of
-  10kpps at the prescribed packet size; these are sent in addition to the main
-  load streams.
-- TG reports min/avg/max latency values per stream direction, hence two sets
-  of latency values are reported per test case; future release of TRex is
-  expected to report latency percentiles.
-- Reported latency values are aggregate across two SUTs due to three node
-  topology used for all performance tests; for per SUT latency, reported value
-  should be divided by two.
-- 1usec is the measurement accuracy advertised by TRex TG for the setup used in
-  FD.io labs used by CSIT project.
-- TRex setup introduces an always-on error of about 2*2usec per latency flow -
-  additonal Tx/Rx interface latency induced by TRex SW writing and reading
-  packet timestamps on CPU cores without HW acceleration on NICs closer to the
-  interface line.
-
-
-Methodology: KVM VM vhost
--------------------------
-
-CSIT |release| introduced environment configuration changes to KVM Qemu vhost-
-user tests in order to more representatively measure |vpp-release| performance
-in configurations with vhost-user interfaces and VMs.
-
-Current setup of CSIT FD.io performance lab is using tuned settings for more
-optimal performance of KVM Qemu:
+.. only:: latex
+
+    .. raw:: latex
+
+        \begin{figure}[H]
+        \centering
+            \includesvg[width=0.90\textwidth]{../_tmp/src/vpp_performance_tests/logical-2n-nic2nic}
+            \label{fig:logical-2n-nic2nic}
+        \end{figure}
+
+.. only:: html
+
+    .. figure:: logical-2n-nic2nic.svg
+        :alt: logical-2n-nic2nic
+        :align: center
+
+
+.. only:: latex
+
+    .. raw:: latex
+
+        \begin{figure}[H]
+        \centering
+            \includesvg[width=0.90\textwidth]{../_tmp/src/vpp_performance_tests/logical-3n-nic2nic}
+            \label{fig:logical-3n-nic2nic}
+        \end{figure}
+
+.. only:: html
+
+    .. figure:: logical-3n-nic2nic.svg
+        :alt: logical-3n-nic2nic
+        :align: center
+
+Server Systems Under Test (SUT) run VPP application in Linux user-mode
+as a Device Under Test (DUT). Server Traffic Generator (TG) runs T-Rex
+application. Physical connectivity between SUTs and TG is provided using
+different drivers and NIC models that need to be tested for performance
+(packet/bandwidth throughput and latency).
+
+From SUT and DUT perspectives, all performance tests involve forwarding
+packets between two (or more) physical Ethernet ports (10GE, 25GE, 40GE,
+100GE). In most cases both physical ports on SUT are located on the same
+NIC. The only exceptions are link bonding and 100GE tests. In the latter
+case only one port per NIC can be driven at linerate due to PCIe Gen3
+x16 slot bandwidth limiations. 100GE NICs are not supported in PCIe Gen3
+x8 slots.
+
+Note that reported VPP DUT performance results are specific to the SUTs
+tested. SUTs with other processors than the ones used in FD.io lab are
+likely to yield different results. A good rule of thumb, that can be
+applied to estimate VPP packet thoughput for NIC-to-NIC switching
+topology, is to expect the forwarding performance to be proportional to
+processor core frequency for the same processor architecture, assuming
+processor is the only limiting factor and all other SUT parameters are
+equivalent to FD.io CSIT environment.
+
+VM Service Switching
+~~~~~~~~~~~~~~~~~~~~
+
+VM service switching topology test cases require VPP DUT to communicate
+with Virtual Machines (VMs) over vhost-user virtual interfaces.
+
+Two types of VM service topologies are tested in CSIT |release|:
+
+#. "Parallel" topology with packets flowing within SUT from NIC(s) via
+   VPP DUT to VM, back to VPP DUT, then out thru NIC(s).
+
+#. "Chained" topology (a.k.a. "Snake") with packets flowing within SUT
+   from NIC(s) via VPP DUT to VM, back to VPP DUT, then to the next VM,
+   back to VPP DUT and so on and so forth until the last VM in a chain,
+   then back to VPP DUT and out thru NIC(s).
+
+For each of the above topologies, VPP DUT is tested in a range of L2
+or IPv4/IPv6 configurations depending on the test suite. Sample VPP DUT
+"Chained" VM service topologies for 2-Node and 3-Node testbeds with each
+SUT running N of VM instances is shown in the figures below.
+
+.. only:: latex
 
-- Qemu virtio queue size has been increased from default value of 256 to 1024
-  descriptors.
-- Adjusted Linux kernel CFS scheduler settings, as detailed on this CSIT wiki
-  page: https://wiki.fd.io/view/CSIT/csit-perf-env-tuning-ubuntu1604.
-
-Adjusted Linux kernel CFS settings make the NDR and PDR throughput performance
-of VPP+VM system less sensitive to other Linux OS system tasks by reducing
-their interference on CPU cores that are designated for critical software
-tasks under test, namely VPP worker threads in host and Testpmd threads in
-guest dealing with data plan.
+    .. raw:: latex
 
-Methodology: IPSec with Intel QAT HW cards
-------------------------------------------
+        \begin{figure}[H]
+        \centering
+            \includesvg[width=0.90\textwidth]{../_tmp/src/vpp_performance_tests/logical-2n-vm-vhost}
+            \label{fig:logical-2n-vm-vhost}
+        \end{figure}
 
-VPP IPSec performance tests are using DPDK cryptodev device driver in
-combination with HW cryptodev devices - Intel QAT 8950 50G - present in
-LF FD.io physical testbeds. DPDK cryptodev can be used for all IPSec
-data plane functions supported by VPP.
+.. only:: html
 
-Currently CSIT |release| implements following IPSec test cases:
+    .. figure:: logical-2n-vm-vhost.svg
+        :alt: logical-2n-vm-vhost
+        :align: center
 
-- AES-GCM, CBC-SHA1 ciphers, in combination with IPv4 routed-forwarding
-  with Intel xl710 NIC.
-- CBC-SHA1 ciphers, in combination with LISP-GPE overlay tunneling for
-  IPv4-over-IPv4 with Intel xl710 NIC.
 
-Methodology: TRex Traffic Generator Usage
------------------------------------------
+.. only:: latex
 
-The `TRex traffic generator <https://wiki.fd.io/view/TRex>`_ is used for all
-CSIT performance tests. TRex stateless mode is used to measure NDR and PDR
-throughputs using binary search (NDR and PDR discovery tests) and for quick
-checks of DUT performance against the reference NDRs (NDR check tests) for
-specific configuration.
+    .. raw:: latex
 
-TRex is installed and run on the TG compute node. The typical procedure is:
+        \begin{figure}[H]
+        \centering
+            \includesvg[width=0.90\textwidth]{../_tmp/src/vpp_performance_tests/logical-3n-vm-vhost}
+            \label{fig:logical-3n-vm-vhost}
+        \end{figure}
 
-    - If the TRex is not already installed on TG, it is installed in the
-      suite setup phase - see `TRex intallation`_.
-    - TRex configuration is set in its configuration file
-      ::
+.. only:: html
 
-        /etc/trex_cfg.yaml
+    .. figure:: logical-3n-vm-vhost.svg
+        :alt: logical-3n-vm-vhost
+        :align: center
 
-    - TRex is started in the background mode
-      ::
+In "Chained" VM topologies, packets are switched by VPP DUT multiple
+times: twice for a single VM, three times for two VMs, N+1 times for N
+VMs. Hence the external throughput rates measured by TG and listed in
+this report must be multiplied by N+1 to represent the actual VPP DUT
+aggregate packet forwarding rate.
 
-        sh -c 'cd /opt/trex-core-2.25/scripts/ && sudo nohup ./t-rex-64 -i -c 7 --iom 0 > /dev/null 2>&1 &' > /dev/null
+For "Parallel" service topology packets are always switched twice by VPP
+DUT per service chain.
 
-    - There are traffic streams dynamically prepared for each test. The traffic
-      is sent and the statistics obtained using trex_stl_lib.api.STLClient.
+Note that reported VPP DUT performance results are specific to the SUTs
+tested. SUTs with other processor than the ones used in FD.io lab are
+likely to yield different results. Similarly to NIC-to-NIC switching
+topology, here one can also expect the forwarding performance to be
+proportional to processor core frequency for the same processor
+architecture, assuming processor is the only limiting factor. However
+due to much higher dependency on intensive memory operations in VM
+service chained topologies and sensitivity to Linux scheduler settings
+and behaviour, this estimation may not always yield good enough
+accuracy.
 
-**Measuring packet loss**
+Container Service Switching
+~~~~~~~~~~~~~~~~~~~~~~~~~~~
 
-    - Create an instance of STLClient
-    - Connect to the client
-    - Add all streams
-    - Clear statistics
-    - Send the traffic for defined time
-    - Get the statistics
+Container service switching topology test cases require VPP DUT to
+communicate with Containers (Ctrs) over memif virtual interfaces.
 
-If there is a warm-up phase required, the traffic is sent also before test and
-the statistics are ignored.
+Three types of VM service topologies are tested in CSIT |release|:
 
-**Measuring latency**
-
-If measurement of latency is requested, two more packet streams are created (one
-for each direction) with TRex flow_stats parameter set to STLFlowLatencyStats. In
-that case, returned statistics will also include min/avg/max latency values.
+#. "Parallel" topology with packets flowing within SUT from NIC(s) via
+   VPP DUT to Container, back to VPP DUT, then out thru NIC(s).
+
+#. "Chained" topology (a.k.a. "Snake") with packets flowing within SUT
+   from NIC(s) via VPP DUT to Container, back to VPP DUT, then to the
+   next Container, back to VPP DUT and so on and so forth until the
+   last Container in a chain, then back to VPP DUT and out thru NIC(s).
+
+#. "Horizontal" topology with packets flowing within SUT from NIC(s) via
+   VPP DUT to Container, then via "horizontal" memif to the next
+   Container, and so on and so forth until the last Container, then
+   back to VPP DUT and out thru NIC(s).
+
+For each of the above topologies, VPP DUT is tested in a range of L2
+or IPv4/IPv6 configurations depending on the test suite. Sample VPP DUT
+"Chained" Container service topologies for 2-Node and 3-Node testbeds
+with each SUT running N of Container instances is shown in the figures
+below.
+
+.. only:: latex
+
+    .. raw:: latex
+
+        \begin{figure}[H]
+        \centering
+            \includesvg[width=0.90\textwidth]{../_tmp/src/vpp_performance_tests/logical-2n-container-memif}
+            \label{fig:logical-2n-container-memif}
+        \end{figure}
+
+.. only:: html
+
+    .. figure:: logical-2n-container-memif.svg
+        :alt: logical-2n-container-memif
+        :align: center
+
+
+.. only:: latex
+
+    .. raw:: latex
+
+        \begin{figure}[H]
+        \centering
+            \includesvg[width=0.90\textwidth]{../_tmp/src/vpp_performance_tests/logical-3n-container-memif}
+            \label{fig:logical-3n-container-memif}
+        \end{figure}
+
+.. only:: html
+
+    .. figure:: logical-3n-container-memif.svg
+        :alt: logical-3n-container-memif
+        :align: center
+
+In "Chained" Container topologies, packets are switched by VPP DUT
+multiple times: twice for a single Container, three times for two
+Containers, N+1 times for N Containers. Hence the external throughput
+rates measured by TG and listed in this report must be multiplied by N+1
+to represent the actual VPP DUT aggregate packet forwarding rate.
+
+For a "Parallel" and "Horizontal" service topologies packets are always
+switched by VPP DUT twice per service chain.
+
+Note that reported VPP DUT performance results are specific to the SUTs
+tested. SUTs with other processor than the ones used in FD.io lab are
+likely to yield different results. Similarly to NIC-to-NIC switching
+topology, here one can also expect the forwarding performance to be
+proportional to processor core frequency for the same processor
+architecture, assuming processor is the only limiting factor. However
+due to much higher dependency on intensive memory operations in
+Container service chained topologies and sensitivity to Linux scheduler
+settings and behaviour, this estimation may not always yield good enough
+accuracy.
+
+Performance Tests Coverage
+--------------------------
+
+Performance tests measure following metrics for tested VPP DUT
+topologies and configurations:
+
+- Packet Throughput: measured in accordance with :rfc:`2544`, using
+  FD.io CSIT Multiple Loss Ratio search (MLRsearch), an optimized binary
+  search algorithm, producing throughput at different Packet Loss Ratio
+  (PLR) values:
+
+  - Non Drop Rate (NDR): packet throughput at PLR=0%.
+  - Partial Drop Rate (PDR): packet throughput at PLR=0.5%.
+
+- One-Way Packet Latency: measured at different offered packet loads:
+
+  - 100% of discovered NDR throughput.
+  - 100% of discovered PDR throughput.
+
+- Maximum Receive Rate (MRR): measure packet forwarding rate under the
+  maximum load offered by traffic generator over a set trial duration,
+  regardless of packet loss. Maximum load for specified Ethernet frame
+  size is set to the bi-directional link rate.
+
+CSIT |release| includes following performance test areas covered across
+a range of NIC drivers and NIC models:
+
++-----------------------+----------------------------------------------+
+| Test Area             |  Description                                 |
++=======================+==============================================+
+| ACL                   | L2 Bridge-Domain switching and               |
+|                       | IPv4and IPv6 routing with iACL and oACL IP   |
+|                       | address, MAC address and L4 port security.   |
++-----------------------+----------------------------------------------+
+| COP                   | IPv4 and IPv6 routing with COP address       |
+|                       | security.                                    |
++-----------------------+----------------------------------------------+
+| IPv4                  | IPv4 routing.                                |
++-----------------------+----------------------------------------------+
+| IPv6                  | IPv6 routing.                                |
++-----------------------+----------------------------------------------+
+| IPv4 Scale            | IPv4 routing with 20k, 200k and 2M FIB       |
+|                       | entries.                                     |
++-----------------------+----------------------------------------------+
+| IPv6 Scale            | IPv6 routing with 20k, 200k and 2M FIB       |
+|                       | entries.                                     |
++-----------------------+----------------------------------------------+
+| IPSecHW               | IPSec encryption with AES-GCM, CBC-SHA1      |
+|                       | ciphers, in combination with IPv4 routing.   |
+|                       | Intel QAT HW acceleration.                   |
++-----------------------+----------------------------------------------+
+| IPSec+LISP            | IPSec encryption with CBC-SHA1 ciphers, in   |
+|                       | combination with LISP-GPE overlay tunneling  |
+|                       | for IPv4-over-IPv4.                          |
++-----------------------+----------------------------------------------+
+| IPSecSW               | IPSec encryption with AES-GCM, CBC-SHA1      |
+|                       | ciphers, in combination with IPv4 routing.   |
++-----------------------+----------------------------------------------+
+| K8s Containers Memif  | K8s orchestrated container VPP service chain |
+|                       | topologies connected over the memif virtual  |
+|                       | interface.                                   |
++-----------------------+----------------------------------------------+
+| KVM VMs vhost-user    | Virtual topologies with service              |
+|                       | chains of 1 and 2 VMs using vhost-user       |
+|                       | interfaces, with different VPP forwarding    |
+|                       | modes incl. L2XC, L2BD, VXLAN with L2BD,     |
+|                       | IPv4 routing.                                |
++-----------------------+----------------------------------------------+
+| L2BD                  | L2 Bridge-Domain switching of untagged       |
+|                       | Ethernet frames with MAC learning; disabled  |
+|                       | MAC learning i.e. static MAC tests to be     |
+|                       | added.                                       |
++-----------------------+----------------------------------------------+
+| L2BD Scale            | L2 Bridge-Domain switching of untagged       |
+|                       | Ethernet frames with MAC learning; disabled  |
+|                       | MAC learning i.e. static MAC tests to be     |
+|                       | added with 20k, 200k and 2M FIB entries.     |
++-----------------------+----------------------------------------------+
+| L2XC                  | L2 Cross-Connect switching of untagged,      |
+|                       | dot1q, dot1ad VLAN tagged Ethernet frames.   |
++-----------------------+----------------------------------------------+
+| LISP                  | LISP overlay tunneling for IPv4-over-IPv4,   |
+|                       | IPv6-over-IPv4, IPv6-over-IPv6,              |
+|                       | IPv4-over-IPv6 in IPv4 and IPv6 routing      |
+|                       | modes.                                       |
++-----------------------+----------------------------------------------+
+| LXC/DRC Containers    | Container VPP memif virtual interface tests  |
+| Memif                 | with different VPP forwarding modes incl.    |
+|                       | L2XC, L2BD.                                  |
++-----------------------+----------------------------------------------+
+| NAT                   | (Source) Network Address Translation tests   |
+|                       | with varying number of users and ports per   |
+|                       | user.                                        |
++-----------------------+----------------------------------------------+
+| QoS Policer           | Ingress packet rate measuring, marking and   |
+|                       | limiting (IPv4).                             |
++-----------------------+----------------------------------------------+
+| SRv6 Routing          | Segment Routing IPv6 tests.                  |
++-----------------------+----------------------------------------------+
+| VPP TCP/IP stack      | Tests of VPP TCP/IP stack used with VPP      |
+|                       | built-in HTTP server.                        |
++-----------------------+----------------------------------------------+
+| VXLAN                 | VXLAN overlay tunnelling integration with    |
+|                       | L2XC and L2BD.                               |
++-----------------------+----------------------------------------------+
+
+Execution of performance tests takes time, especially the throughput
+tests. Due to limited HW testbed resources available within FD.io labs
+hosted by :abbr:`LF (Linux Foundation)`, the number of tests for some
+NIC models has been limited to few baseline tests.
+
+Performance Tests Naming
+------------------------
+
+FD.io CSIT |release| follows a common structured naming convention for
+all performance and system functional tests, introduced in CSIT rls1701.
+
+The naming should be intuitive for majority of the tests. Complete
+description of FD.io CSIT test naming convention is provided on
+:ref:`csit_test_naming`.