Trending: NFV Tests
[csit.git] / resources / tools / presentation / specification_CPTA.yaml
index ae87878..579d9c5 100644 (file)
 
     plot-performance-trending-vpp-nfv-2n-skx:
       csit-vpp-perf-mrr-weekly-master-2n-skx:
-        start: 50
+        start: 66
         end: "lastCompletedBuild"
         max-builds: 26
+        skip:
+          - 68
+          - 72
+          - 73
+          - 75
+          - 76
 
+    # 2n-clx
     plot-performance-trending-vpp-2n-clx:
       csit-vpp-perf-mrr-daily-master-2n-clx:
         start: 236
         end: "lastCompletedBuild"
         max-builds: 180
 
+    plot-performance-trending-vpp-nfv-2n-clx:
+      csit-vpp-perf-mrr-weekly-master-2n-clx:
+        start: 37
+        end: "lastCompletedBuild"
+        max-builds: 26
+        skip:
+          - 39
+          - 45
+          - 48
+
     plot-performance-trending-dpdk-2n-clx:
       csit-dpdk-perf-mrr-weekly-master-2n-clx:
         start: 23
         - 874
         - 889
     csit-vpp-perf-mrr-weekly-master-2n-skx:
-      start: 50
+      start: 66
       end: "lastCompletedBuild"
       max-builds: 26  # Max nr of builds to download
       skip:
-        - 52
-        - 54
-        - 55
+        - 68
+        - 72
+        - 73
+        - 75
+        - 76
+
     csit-dpdk-perf-mrr-weekly-master-2n-skx:
       start: 78
       end: "lastCompletedBuild"
         - 252
         - 253
         - 308
+    csit-vpp-perf-mrr-weekly-master-2n-clx:
+      start: 37
+      end: "lastCompletedBuild"
+      max-builds: 26  # Max nr of builds to download
+      skip:
+        - 39
+        - 45
+        - 48
 
     csit-dpdk-perf-mrr-weekly-master-2n-clx:
       start: 23
 ################################################################################
 # NFV
 
+# 2n-skx
+
     - title: "VPP 2T1C NF Service Density VNFc IMIX MRR Trending 2n-skx"
-      output-file-name: "2n-skx-xxv710-imix-2t1c-vhost-chains-dpdk"
+      output-file-name: "2n-skx-xxv710-imix-2t1c-vhost-chains-avf"
       data: "plot-performance-trending-vpp-nfv-2n-skx"
-      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '2T1C' and 'L2BDMACLRN' and not 'VXLAN'"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '2T1C' and 'L2BDMACLRN' and not 'VXLAN' and 'DRV_AVF'"
       groups:
         - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
         - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
       layout: "plot-cpta"
 
     - title: "VPP 4T2C NF Service Density VNFc IMIX MRR Trending 2n-skx"
-      output-file-name: "2n-skx-xxv710-imix-4t2c-vhost-chains-dpdk"
+      output-file-name: "2n-skx-xxv710-imix-4t2c-vhost-chains-avf"
       data: "plot-performance-trending-vpp-nfv-2n-skx"
-      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '4T2C' and 'L2BDMACLRN' and not 'VXLAN'"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '4T2C' and 'L2BDMACLRN' and not 'VXLAN' and 'DRV_AVF'"
       groups:
         - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
         - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
       layout: "plot-cpta"
 
     - title: "VPP 8T4C NF Service Density VNFc IMIX MRR Trending 2n-skx"
-      output-file-name: "2n-skx-xxv710-imix-8t4c-vhost-chains-dpdk"
+      output-file-name: "2n-skx-xxv710-imix-8t4c-vhost-chains-avf"
       data: "plot-performance-trending-vpp-nfv-2n-skx"
-      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '8T4C' and 'L2BDMACLRN' and not 'VXLAN'"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '8T4C' and 'L2BDMACLRN' and not 'VXLAN' and 'DRV_AVF'"
       groups:
         - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
         - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
       layout: "plot-cpta"
 
     - title: "VPP 2T1C NF Service Density VNFc VXLAN IMIX MRR Trending 2n-skx"
-      output-file-name: "2n-skx-xxv710-imix-2t1c-vhost-chains-vxlan-dpdk"
+      output-file-name: "2n-skx-xxv710-imix-2t1c-vhost-chains-vxlan-avf"
       data: "plot-performance-trending-vpp-nfv-2n-skx"
-      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '2T1C' and 'L2BDMACLRN' and 'VXLAN'"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '2T1C' and 'L2BDMACLRN' and 'VXLAN' and 'DRV_AVF'"
       groups:
         - ["1R1C", ]
         - ["2R1C", ]
       layout: "plot-cpta"
 
     - title: "VPP 4T2C NF Service Density VNFc VXLAN IMIX MRR Trending 2n-skx"
-      output-file-name: "2n-skx-xxv710-imix-4t2c-vhost-chains-vxlan-dpdk"
+      output-file-name: "2n-skx-xxv710-imix-4t2c-vhost-chains-vxlan-avf"
       data: "plot-performance-trending-vpp-nfv-2n-skx"
-      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '4T2C' and 'L2BDMACLRN' and 'VXLAN'"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '4T2C' and 'L2BDMACLRN' and 'VXLAN' and 'DRV_AVF'"
       groups:
         - ["1R1C", ]
         - ["2R1C", ]
       layout: "plot-cpta"
 
     - title: "VPP 8T4C NF Service Density VNFc VXLAN IMIX MRR Trending 2n-skx"
-      output-file-name: "2n-skx-xxv710-imix-8t4c-vhost-chains-vxlan-dpdk"
+      output-file-name: "2n-skx-xxv710-imix-8t4c-vhost-chains-vxlan-avf"
       data: "plot-performance-trending-vpp-nfv-2n-skx"
-      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '8T4C' and 'L2BDMACLRN' and 'VXLAN'"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '8T4C' and 'L2BDMACLRN' and 'VXLAN' and 'DRV_AVF'"
       groups:
         - ["1R1C", ]
         - ["2R1C", ]
       layout: "plot-cpta"
 
     - title: "VPP 2T1C NF Service Density CNFc IMIX MRR Trending 2n-skx"
-      output-file-name: "2n-skx-xxv710-imix-2t1c-memif-chains-dpdk"
+      output-file-name: "2n-skx-xxv710-imix-2t1c-memif-chains-avf"
       data: "plot-performance-trending-vpp-nfv-2n-skx"
-      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'CHAIN' and 'MRR' and 'IMIX' and '2T1C' and 'L2BDMACLRN'"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'CHAIN' and 'MRR' and 'IMIX' and '2T1C' and 'L2BDMACLRN' and 'DRV_AVF'"
       groups:
         - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
         - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
       layout: "plot-cpta"
 
     - title: "VPP 4T2C NF Service Density CNFc IMIX MRR Trending 2n-skx"
-      output-file-name: "2n-skx-xxv710-imix-4t2c-memif-chains-dpdk"
+      output-file-name: "2n-skx-xxv710-imix-4t2c-memif-chains-avf"
       data: "plot-performance-trending-vpp-nfv-2n-skx"
-      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'CHAIN' and 'MRR' and 'IMIX' and '4T2C' and 'L2BDMACLRN'"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'CHAIN' and 'MRR' and 'IMIX' and '4T2C' and 'L2BDMACLRN' and 'DRV_AVF'"
       groups:
         - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
         - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
       layout: "plot-cpta"
 
     - title: "VPP 8T4C NF Service Density CNFc IMIX MRR Trending 2n-skx"
-      output-file-name: "2n-skx-xxv710-imix-8t4c-memif-chains-dpdk"
+      output-file-name: "2n-skx-xxv710-imix-8t4c-memif-chains-avf"
       data: "plot-performance-trending-vpp-nfv-2n-skx"
-      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'CHAIN' and 'MRR' and 'IMIX' and '8T4C' and 'L2BDMACLRN'"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'CHAIN' and 'MRR' and 'IMIX' and '8T4C' and 'L2BDMACLRN' and 'DRV_AVF'"
       groups:
         - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
         - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
       layout: "plot-cpta"
 
     - title: "VPP 2T1C NF Service Density CNFp IMIX MRR Trending 2n-skx"
-      output-file-name: "2n-skx-xxv710-imix-2t1c-memif-pipelines-dpdk"
+      output-file-name: "2n-skx-xxv710-imix-2t1c-memif-pipelines-avf"
       data: "plot-performance-trending-vpp-nfv-2n-skx"
-      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'PIPELINE' and 'MRR' and 'IMIX' and '2T1C' and 'L2BDMACLRN'"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'PIPELINE' and 'MRR' and 'IMIX' and '2T1C' and 'L2BDMACLRN' and 'DRV_AVF'"
       groups:
         - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
         - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
       layout: "plot-cpta"
 
     - title: "VPP 4T2C NF Service Density CNFp IMIX MRR Trending 2n-skx"
-      output-file-name: "2n-skx-xxv710-imix-4t2c-memif-pipelines-dpdk"
+      output-file-name: "2n-skx-xxv710-imix-4t2c-memif-pipelines-avf"
       data: "plot-performance-trending-vpp-nfv-2n-skx"
-      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'PIPELINE' and 'MRR' and 'IMIX' and '4T2C' and 'L2BDMACLRN'"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'PIPELINE' and 'MRR' and 'IMIX' and '4T2C' and 'L2BDMACLRN' and 'DRV_AVF'"
       groups:
         - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
         - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
       layout: "plot-cpta"
 
     - title: "VPP 8T4C NF Service Density CNFp IMIX MRR Trending 2n-skx"
-      output-file-name: "2n-skx-xxv710-imix-8t4c-memif-pipelines-dpdk"
+      output-file-name: "2n-skx-xxv710-imix-8t4c-memif-pipelines-avf"
       data: "plot-performance-trending-vpp-nfv-2n-skx"
-      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'PIPELINE' and 'MRR' and 'IMIX' and '8T4C' and 'L2BDMACLRN'"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'PIPELINE' and 'MRR' and 'IMIX' and '8T4C' and 'L2BDMACLRN' and 'DRV_AVF'"
+      groups:
+        - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
+        - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
+        - ["4R1C", "4R2C", "4R4C", "4R6C"]
+        - ["6R1C", "6R2C", "6R4C"]
+        - ["8R1C", "8R2C"]
+        - ["10R1C", "10R2C"]
+      group-names:
+        - "1 Pipe"
+        - "2 Pipes"
+        - "4 Pipes"
+        - "6 Pipes"
+        - "8 Pipes"
+        - "10 Pipes"
+      layout: "plot-cpta"
+
+# 2n-clx
+
+    - title: "VPP 2T1C NF Service Density VNFc IMIX MRR Trending 2n-clx"
+      output-file-name: "2n-clx-xxv710-imix-2t1c-vhost-chains-avf"
+      data: "plot-performance-trending-vpp-nfv-2n-clx"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '2T1C' and 'L2BDMACLRN' and not 'VXLAN' and 'DRV_AVF'"
+      groups:
+        - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
+        - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
+        - ["4R1C", "4R2C", "4R4C", "4R6C"]
+        - ["6R1C", "6R2C", "6R4C"]
+        - ["8R1C", "8R2C"]
+        - ["10R1C", "10R2C"]
+      group-names:
+        - "1 Chain"
+        - "2 Chains"
+        - "4 Chains"
+        - "6 Chains"
+        - "8 Chains"
+        - "10 Chains"
+      layout: "plot-cpta"
+
+    - title: "VPP 4T2C NF Service Density VNFc IMIX MRR Trending 2n-clx"
+      output-file-name: "2n-clx-xxv710-imix-4t2c-vhost-chains-avf"
+      data: "plot-performance-trending-vpp-nfv-2n-clx"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '4T2C' and 'L2BDMACLRN' and not 'VXLAN' and 'DRV_AVF'"
+      groups:
+        - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
+        - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
+        - ["4R1C", "4R2C", "4R4C", "4R6C"]
+        - ["6R1C", "6R2C", "6R4C"]
+        - ["8R1C", "8R2C"]
+        - ["10R1C", "10R2C"]
+      group-names:
+        - "1 Chain"
+        - "2 Chains"
+        - "4 Chains"
+        - "6 Chains"
+        - "8 Chains"
+        - "10 Chains"
+      layout: "plot-cpta"
+
+    - title: "VPP 8T4C NF Service Density VNFc IMIX MRR Trending 2n-clx"
+      output-file-name: "2n-clx-xxv710-imix-8t4c-vhost-chains-avf"
+      data: "plot-performance-trending-vpp-nfv-2n-clx"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '8T4C' and 'L2BDMACLRN' and not 'VXLAN' and 'DRV_AVF'"
+      groups:
+        - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
+        - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
+        - ["4R1C", "4R2C", "4R4C", "4R6C"]
+        - ["6R1C", "6R2C", "6R4C"]
+        - ["8R1C", "8R2C"]
+        - ["10R1C", "10R2C"]
+      group-names:
+        - "1 Chain"
+        - "2 Chains"
+        - "4 Chains"
+        - "6 Chains"
+        - "8 Chains"
+        - "10 Chains"
+      layout: "plot-cpta"
+
+    - title: "VPP 2T1C NF Service Density VNFc VXLAN IMIX MRR Trending 2n-clx"
+      output-file-name: "2n-clx-xxv710-imix-2t1c-vhost-chains-vxlan-avf"
+      data: "plot-performance-trending-vpp-nfv-2n-clx"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '2T1C' and 'L2BDMACLRN' and 'VXLAN' and 'DRV_AVF'"
+      groups:
+        - ["1R1C", ]
+        - ["2R1C", ]
+        - ["4R1C", ]
+        - ["6R1C", ]
+        - ["8R1C", ]
+        - ["10R1C", ]
+      group-names:
+        - "1 Chain"
+        - "2 Chains"
+        - "4 Chains"
+        - "6 Chains"
+        - "8 Chains"
+        - "10 Chains"
+      layout: "plot-cpta"
+
+    - title: "VPP 4T2C NF Service Density VNFc VXLAN IMIX MRR Trending 2n-clx"
+      output-file-name: "2n-clx-xxv710-imix-4t2c-vhost-chains-vxlan-avf"
+      data: "plot-performance-trending-vpp-nfv-2n-clx"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '4T2C' and 'L2BDMACLRN' and 'VXLAN' and 'DRV_AVF'"
+      groups:
+        - ["1R1C", ]
+        - ["2R1C", ]
+        - ["4R1C", ]
+        - ["6R1C", ]
+        - ["8R1C", ]
+        - ["10R1C", ]
+      group-names:
+        - "1 Chain"
+        - "2 Chains"
+        - "4 Chains"
+        - "6 Chains"
+        - "8 Chains"
+        - "10 Chains"
+      layout: "plot-cpta"
+
+    - title: "VPP 8T4C NF Service Density VNFc VXLAN IMIX MRR Trending 2n-clx"
+      output-file-name: "2n-clx-xxv710-imix-8t4c-vhost-chains-vxlan-avf"
+      data: "plot-performance-trending-vpp-nfv-2n-clx"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'VM' and 'CHAIN' and 'MRR' and 'IMIX' and '8T4C' and 'L2BDMACLRN' and 'VXLAN' and 'DRV_AVF'"
+      groups:
+        - ["1R1C", ]
+        - ["2R1C", ]
+        - ["4R1C", ]
+        - ["6R1C", ]
+        - ["8R1C", ]
+        - ["10R1C", ]
+      group-names:
+        - "1 Chain"
+        - "2 Chains"
+        - "4 Chains"
+        - "6 Chains"
+        - "8 Chains"
+        - "10 Chains"
+      layout: "plot-cpta"
+
+    - title: "VPP 2T1C NF Service Density CNFc IMIX MRR Trending 2n-clx"
+      output-file-name: "2n-clx-xxv710-imix-2t1c-memif-chains-avf"
+      data: "plot-performance-trending-vpp-nfv-2n-clx"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'CHAIN' and 'MRR' and 'IMIX' and '2T1C' and 'L2BDMACLRN' and 'DRV_AVF'"
+      groups:
+        - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
+        - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
+        - ["4R1C", "4R2C", "4R4C", "4R6C"]
+        - ["6R1C", "6R2C", "6R4C"]
+        - ["8R1C", "8R2C"]
+        - ["10R1C", "10R2C"]
+      group-names:
+        - "1 Chain"
+        - "2 Chains"
+        - "4 Chains"
+        - "6 Chains"
+        - "8 Chains"
+        - "10 Chains"
+      layout: "plot-cpta"
+
+    - title: "VPP 4T2C NF Service Density CNFc IMIX MRR Trending 2n-clx"
+      output-file-name: "2n-clx-xxv710-imix-4t2c-memif-chains-avf"
+      data: "plot-performance-trending-vpp-nfv-2n-clx"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'CHAIN' and 'MRR' and 'IMIX' and '4T2C' and 'L2BDMACLRN' and 'DRV_AVF'"
+      groups:
+        - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
+        - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
+        - ["4R1C", "4R2C", "4R4C", "4R6C"]
+        - ["6R1C", "6R2C", "6R4C"]
+        - ["8R1C", "8R2C"]
+        - ["10R1C", "10R2C"]
+      group-names:
+        - "1 Chain"
+        - "2 Chains"
+        - "4 Chains"
+        - "6 Chains"
+        - "8 Chains"
+        - "10 Chains"
+      layout: "plot-cpta"
+
+    - title: "VPP 8T4C NF Service Density CNFc IMIX MRR Trending 2n-clx"
+      output-file-name: "2n-clx-xxv710-imix-8t4c-memif-chains-avf"
+      data: "plot-performance-trending-vpp-nfv-2n-clx"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'CHAIN' and 'MRR' and 'IMIX' and '8T4C' and 'L2BDMACLRN' and 'DRV_AVF'"
+      groups:
+        - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
+        - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
+        - ["4R1C", "4R2C", "4R4C", "4R6C"]
+        - ["6R1C", "6R2C", "6R4C"]
+        - ["8R1C", "8R2C"]
+        - ["10R1C", "10R2C"]
+      group-names:
+        - "1 Chain"
+        - "2 Chains"
+        - "4 Chains"
+        - "6 Chains"
+        - "8 Chains"
+        - "10 Chains"
+      layout: "plot-cpta"
+
+    - title: "VPP 2T1C NF Service Density CNFp IMIX MRR Trending 2n-clx"
+      output-file-name: "2n-clx-xxv710-imix-2t1c-memif-pipelines-avf"
+      data: "plot-performance-trending-vpp-nfv-2n-clx"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'PIPELINE' and 'MRR' and 'IMIX' and '2T1C' and 'L2BDMACLRN' and 'DRV_AVF'"
+      groups:
+        - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
+        - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
+        - ["4R1C", "4R2C", "4R4C", "4R6C"]
+        - ["6R1C", "6R2C", "6R4C"]
+        - ["8R1C", "8R2C"]
+        - ["10R1C", "10R2C"]
+      group-names:
+        - "1 Pipe"
+        - "2 Pipes"
+        - "4 Pipes"
+        - "6 Pipes"
+        - "8 Pipes"
+        - "10 Pipes"
+      layout: "plot-cpta"
+
+    - title: "VPP 4T2C NF Service Density CNFp IMIX MRR Trending 2n-clx"
+      output-file-name: "2n-clx-xxv710-imix-4t2c-memif-pipelines-avf"
+      data: "plot-performance-trending-vpp-nfv-2n-clx"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'PIPELINE' and 'MRR' and 'IMIX' and '4T2C' and 'L2BDMACLRN' and 'DRV_AVF'"
+      groups:
+        - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
+        - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]
+        - ["4R1C", "4R2C", "4R4C", "4R6C"]
+        - ["6R1C", "6R2C", "6R4C"]
+        - ["8R1C", "8R2C"]
+        - ["10R1C", "10R2C"]
+      group-names:
+        - "1 Pipe"
+        - "2 Pipes"
+        - "4 Pipes"
+        - "6 Pipes"
+        - "8 Pipes"
+        - "10 Pipes"
+      layout: "plot-cpta"
+
+    - title: "VPP 8T4C NF Service Density CNFp IMIX MRR Trending 2n-clx"
+      output-file-name: "2n-clx-xxv710-imix-8t4c-memif-pipelines-avf"
+      data: "plot-performance-trending-vpp-nfv-2n-clx"
+      filter: "'NIC_Intel-XXV710' and 'NF_DENSITY' and 'DOCKER' and 'PIPELINE' and 'MRR' and 'IMIX' and '8T4C' and 'L2BDMACLRN' and 'DRV_AVF'"
       groups:
         - ["1R1C", "1R2C", "1R4C", "1R6C", "1R8C", "1R10C"]
         - ["2R1C", "2R2C", "2R4C", "2R6C", "2R8C", "2R10C"]