CSIT-562 HC Test: Persistence suite rework, part1
[csit.git] / tests / perf / 10ge2p1x520-dot1ad-l2xcbase-ndrchk.robot
index 9430aea..4cdfd86 100644 (file)
@@ -1,4 +1,4 @@
-# Copyright (c) 2016 Cisco and/or its affiliates.
+# Copyright (c) 2017 Cisco and/or its affiliates.
 # Licensed under the Apache License, Version 2.0 (the "License");
 # you may not use this file except in compliance with the License.
 # You may obtain a copy of the License at:
 *** Settings ***
 | Resource | resources/libraries/robot/performance.robot
 | Resource | resources/libraries/robot/tagging.robot
+| ...
 | Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRCHK
-| ...        | NIC_Intel-X520-DA2 | L2XCFWD | BASE | DOT1AD
+| ... | NIC_Intel-X520-DA2 | L2XCFWD | BASE | DOT1AD
+| ...
 | Suite Setup | 3-node Performance Suite Setup with DUT's NIC model
 | ... | L2 | Intel-X520-DA2
 | Suite Teardown | 3-node Performance Suite Teardown
-| Test Setup | Setup all DUTs before test
-| Test Teardown | Run Keywords | Remove startup configuration of VPP from all DUTs
-| ...           | AND          | Show vpp trace dump on all DUTs
+| ...
+| Test Setup | Performance test setup
+| Test Teardown | Performance ndrchk test teardown
+| ...
 | Documentation | *Reference NDR throughput L2XC with 802.1ad verify test cases*
 | ...
 | ... | *[Top] Network Topologies:* TG-DUT1-DUT2-TG 3-node circular topology
 | | [Documentation]
 | | ... | [Cfg] DUT runs L2XC with 802.1ad config with 1 thread, 1 phy core, \
 | | ... | 1 receive queue per NIC port. [Ver] Verify ref-NDR for 64 Byte
-| | ... | frames using single trial throughput test at 2x 2.9mpps.
-| | [Tags] | 1T1C | STHREAD
-| | ${framesize}= | Set Variable | 64
-| | ${duration}= | Set Variable | 10
-| | ${rate}= | Set Variable | 2.9mpps
+| | ... | frames using single trial throughput test at 2x 4.0mpps.
+| | [Tags] | 64B | 1T1C | STHREAD
+| | ${framesize}= | Set Variable | ${64}
+| | ${rate}= | Set Variable | 4.0mpps
 | | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Add No Multi Seg to all DUTs
-| | And   Apply startup configuration on all VPP DUTs
-| | And   VPP interfaces in path are up in a 3-node circular topology
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | And VPP interfaces in path are up in a 3-node circular topology
 | | When VLAN subinterfaces initialized on 3-node topology
 | | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid}
 | | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif}
 | | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect
 | | ... | ${dut1} | ${dut1_if1} | ${subif_index_1}
 | | ... | ${dut2} | ${dut2_if2} | ${subif_index_2}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-xconnect
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | 3-node-xconnect
 
 | tc02-1514B-1t1c-dot1ad-l2xcbase-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs L2XC with 802.1ad config with 1 thread, 1 phy core, \
 | | ... | 1 receive queue per NIC port. [Ver] Verify ref-NDR for 1514 Byte
 | | ... | frames using single trial throughput test at 2x 810635pps.
-| | [Tags] | 1T1C | STHREAD
-| | ${framesize}= | Set Variable | 1514
-| | ${duration}= | Set Variable | 10
+| | [Tags] | 1514B | 1T1C | STHREAD
+| | ${framesize}= | Set Variable | ${1514}
 | | ${rate}= | Set Variable | 810635pps
 | | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Add No Multi Seg to all DUTs
-| | And   Apply startup configuration on all VPP DUTs
-| | And   VPP interfaces in path are up in a 3-node circular topology
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | And VPP interfaces in path are up in a 3-node circular topology
 | | When VLAN subinterfaces initialized on 3-node topology
 | | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid}
 | | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif}
 | | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect
 | | ... | ${dut1} | ${dut1_if1} | ${subif_index_1}
 | | ... | ${dut2} | ${dut2_if2} | ${subif_index_2}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-xconnect
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | 3-node-xconnect
 
 | tc03-9000B-1t1c-dot1ad-l2xcbase-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs L2XC with 802.1ad config with 1 thread, 1 phy core, \
 | | ... | 1 receive queue per NIC port. [Ver] Verify ref-NDR for 9000 Byte
 | | ... | frames using single trial throughput test at 2x 138458pps.
-| | [Tags] | 1T1C | STHREAD
-| | ${framesize}= | Set Variable | 9000
-| | ${duration}= | Set Variable | 10
+| | [Tags] | 9000B | 1T1C | STHREAD
+| | ${framesize}= | Set Variable | ${9000}
 | | ${rate}= | Set Variable | 138458pps
 | | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Apply startup configuration on all VPP DUTs
-| | And   VPP interfaces in path are up in a 3-node circular topology
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Apply startup configuration on all VPP DUTs
+| | And VPP interfaces in path are up in a 3-node circular topology
 | | When VLAN subinterfaces initialized on 3-node topology
 | | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid}
 | | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif}
 | | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect
 | | ... | ${dut1} | ${dut1_if1} | ${subif_index_1}
 | | ... | ${dut2} | ${dut2_if2} | ${subif_index_2}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-xconnect
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | 3-node-xconnect
 
 | tc04-64B-2t2c-dot1ad-l2xcbase-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs L2XC with 802.1ad config with 2 thread, 2 phy core, \
 | | ... | 1 receive queue per NIC port. [Ver] Verify ref-NDR for 64 Byte
-| | ... | frames using single trial throughput test at 2x 7.0mpps.
-| | [Tags] | 2T2C | MTHREAD
-| | ${framesize}= | Set Variable | 64
-| | ${duration}= | Set Variable | 10
-| | ${rate}= | Set Variable | 7.0mpps
+| | ... | frames using single trial throughput test at 2x 8.5mpps.
+| | [Tags] | 64B | 2T2C | MTHREAD
+| | ${framesize}= | Set Variable | ${64}
+| | ${rate}= | Set Variable | 8.5mpps
 | | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Add No Multi Seg to all DUTs
-| | And   Apply startup configuration on all VPP DUTs
-| | And   VPP interfaces in path are up in a 3-node circular topology
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | And VPP interfaces in path are up in a 3-node circular topology
 | | When VLAN subinterfaces initialized on 3-node topology
 | | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid}
 | | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif}
 | | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect
 | | ... | ${dut1} | ${dut1_if1} | ${subif_index_1}
 | | ... | ${dut2} | ${dut2_if2} | ${subif_index_2}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-xconnect
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | 3-node-xconnect
 
 | tc05-1514B-2t2c-dot1ad-l2xcbase-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs L2XC with 802.1ad config with 2 thread, 2 phy core, \
 | | ... | 1 receive queue per NIC port. [Ver] Verify ref-NDR for 1514 Byte
 | | ... | frames using single trial throughput test at 2x 810635pps.
-| | [Tags] | 2T2C | MTHREAD
-| | ${framesize}= | Set Variable | 1514
-| | ${duration}= | Set Variable | 10
+| | [Tags] | 1514B | 2T2C | MTHREAD
+| | ${framesize}= | Set Variable | ${1514}
 | | ${rate}= | Set Variable | 810635pps
 | | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Add No Multi Seg to all DUTs
-| | And   Apply startup configuration on all VPP DUTs
-| | And   VPP interfaces in path are up in a 3-node circular topology
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | And VPP interfaces in path are up in a 3-node circular topology
 | | When VLAN subinterfaces initialized on 3-node topology
 | | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid}
 | | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif}
 | | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect
 | | ... | ${dut1} | ${dut1_if1} | ${subif_index_1}
 | | ... | ${dut2} | ${dut2_if2} | ${subif_index_2}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-xconnect
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | 3-node-xconnect
 
 | tc06-9000B-2t2c-dot1ad-l2xcbase-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs L2XC with 802.1ad config with 2 thread, 2 phy core, \
 | | ... | 1 receive queue per NIC port. [Ver] Verify ref-NDR for 9000 Byte
 | | ... | frames using single trial throughput test at 2x 138458pps.
-| | [Tags] | 2T2C | MTHREAD
-| | ${framesize}= | Set Variable | 9000
-| | ${duration}= | Set Variable | 10
+| | [Tags] | 9000B | 2T2C | MTHREAD
+| | ${framesize}= | Set Variable | ${9000}
 | | ${rate}= | Set Variable | 138458pps
 | | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Apply startup configuration on all VPP DUTs
-| | And   VPP interfaces in path are up in a 3-node circular topology
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Apply startup configuration on all VPP DUTs
+| | And VPP interfaces in path are up in a 3-node circular topology
 | | When VLAN subinterfaces initialized on 3-node topology
 | | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid}
 | | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif}
 | | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect
 | | ... | ${dut1} | ${dut1_if1} | ${subif_index_1}
 | | ... | ${dut2} | ${dut2_if2} | ${subif_index_2}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-xconnect
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | 3-node-xconnect
 
 | tc07-64B-4t4c-dot1ad-l2xcbase-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs L2XC with 802.1ad config with 4 thread, 4 phy core, \
 | | ... | 2 receive queue per NIC port. [Ver] Verify ref-NDR for 64 Byte
-| | ... | frames using single trial throughput test at 2x 8.0mpps.
-| | [Tags] | 4T4C | MTHREAD
-| | ${framesize}= | Set Variable | 64
-| | ${duration}= | Set Variable | 10
-| | ${rate}= | Set Variable | 8.0mpps
+| | ... | frames using single trial throughput test at 2x 8.6mpps.
+| | [Tags] | 64B | 4T4C | MTHREAD
+| | ${framesize}= | Set Variable | ${64}
+| | ${rate}= | Set Variable | 8.6mpps
 | | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Add No Multi Seg to all DUTs
-| | And   Apply startup configuration on all VPP DUTs
-| | And   VPP interfaces in path are up in a 3-node circular topology
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | And VPP interfaces in path are up in a 3-node circular topology
 | | When VLAN subinterfaces initialized on 3-node topology
 | | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid}
 | | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif}
 | | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect
 | | ... | ${dut1} | ${dut1_if1} | ${subif_index_1}
 | | ... | ${dut2} | ${dut2_if2} | ${subif_index_2}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-xconnect
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | 3-node-xconnect
 
 | tc08-1514B-4t4c-dot1ad-l2xcbase-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs L2XC with 802.1ad config with 4 thread, 4 phy core, \
 | | ... | 2 receive queue per NIC port. [Ver] Verify ref-NDR for 1514 Byte
 | | ... | frames using single trial throughput test at 2x 810635pps.
-| | [Tags] | 4T4C | MTHREAD
-| | ${framesize}= | Set Variable | 1514
-| | ${duration}= | Set Variable | 10
+| | [Tags] | 1514B | 4T4C | MTHREAD
+| | ${framesize}= | Set Variable | ${1514}
 | | ${rate}= | Set Variable | 810635pps
 | | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Add No Multi Seg to all DUTs
-| | And   Apply startup configuration on all VPP DUTs
-| | And   VPP interfaces in path are up in a 3-node circular topology
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Add No Multi Seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | And VPP interfaces in path are up in a 3-node circular topology
 | | When VLAN subinterfaces initialized on 3-node topology
 | | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid}
 | | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif}
 | | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect
 | | ... | ${dut1} | ${dut1_if1} | ${subif_index_1}
 | | ... | ${dut2} | ${dut2_if2} | ${subif_index_2}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-xconnect
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | 3-node-xconnect
 
 | tc09-9000B-4t4c-dot1ad-l2xcbase-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs L2XC with 802.1ad config with 4 thread, 4 phy core, \
 | | ... | 2 receive queue per NIC port. [Ver] Verify ref-NDR for 9000 Byte
 | | ... | frames using single trial throughput test at 2x 138458pps.
-| | [Tags] | 4T4C | MTHREAD
-| | ${framesize}= | Set Variable | 9000
-| | ${duration}= | Set Variable | 10
+| | [Tags] | 9000B | 4T4C | MTHREAD
+| | ${framesize}= | Set Variable | ${9000}
 | | ${rate}= | Set Variable | 138458pps
 | | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Apply startup configuration on all VPP DUTs
-| | And   VPP interfaces in path are up in a 3-node circular topology
+| | And Add PCI devices to DUTs from 3-node single link topology
+| | And Apply startup configuration on all VPP DUTs
+| | And VPP interfaces in path are up in a 3-node circular topology
 | | When VLAN subinterfaces initialized on 3-node topology
 | | ... | ${dut1} | ${dut1_if2} | ${dut2} | ${dut2_if1} | ${subid}
 | | ... | ${outer_vlan_id} | ${inner_vlan_id} | ${type_subif}
 | | And Interfaces and VLAN sub-interfaces inter-connected using L2-xconnect
 | | ... | ${dut1} | ${dut1_if1} | ${subif_index_1}
 | | ... | ${dut2} | ${dut2_if2} | ${subif_index_2}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-xconnect
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | 3-node-xconnect