CSIT-678: Re-organize L2 libraries - performance
[csit.git] / tests / perf / 10ge2p1x520-ethip6lispip4-ip6base-ndrchk.robot
index 985a56c..aaccec6 100644 (file)
@@ -1,4 +1,4 @@
-# Copyright (c) 2016 Cisco and/or its affiliates.
+# Copyright (c) 2017 Cisco and/or its affiliates.
 # Licensed under the Apache License, Version 2.0 (the "License");
 # you may not use this file except in compliance with the License.
 # You may obtain a copy of the License at:
 # limitations under the License.
 
 *** Settings ***
-| Resource | resources/libraries/robot/performance.robot
+| Resource | resources/libraries/robot/performance_setup.robot
 | Resource | resources/libraries/robot/lisp/lisp_static_adjacency.robot
-| Library | resources.libraries.python.IPv4Setup.Dut | ${nodes['DUT1']}
-| ...     | WITH NAME | dut1_v4
-| Library | resources.libraries.python.IPv4Setup.Dut | ${nodes['DUT2']}
-| ...     | WITH NAME | dut2_v4
-# import additional Lisp settings from resource file
 | Variables | resources/test_data/lisp/performance/lisp_static_adjacency.py
-| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | PERFTEST_SHORT
-| ...        | NIC_Intel-X520-DA2 | PERFTEST_ENCAP | LISP
-| Suite Setup | 3-node Performance Suite Setup with DUT's NIC model
+| ...
+| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRCHK
+| ... | NIC_Intel-X520-DA2 | IP6FWD | ENCAP | LISP | IP4UNRLAY | IP6OVRLAY
+| ...
+| Suite Setup | Set up 3-node performance topology with DUT's NIC model
 | ... | L3 | Intel-X520-DA2
-| Suite Teardown | 3-node Performance Suite Teardown
-| Test Setup | Setup all DUTs before test
-| Test Teardown | Run Keyword | Remove startup configuration of VPP from all DUTs
+| Suite Teardown | Tear down 3-node performance topology
+| ...
+| Test Setup | Set up performance test
+| Test Teardown | Tear down performance ndrchk test
+| ...
 | Documentation | *Reference NDR throughput Lisp tunnel verify test cases*
 | ...
 | ... | *[Top] Network Topologies:* TG-DUT1-DUT2-TG 3-node circular topology
 | ... | IP protocol=61 and generated payload.
 | ... | *[Ref] Applicable standard specifications:* RFC2544.
 
+*** Variables ***
+# Traffic profile:
+| ${traffic_profile} | trex-sl-3n-ethip6-ip6src253
+
 *** Test Cases ***
-| TC01: Verify 78B ref-NDR at 2x 1.75Mpps - DUT IPv6oIPv4 - 1thread 1core 1rxq
+| tc01-78B-1t1c-ethip6lispip4-ip6base-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs LISP tunnel config with 1 thread, 1 phy core,\
 | | ... | 1 receive queue per NIC port.
 | | ... | [Ver] Verify ref-NDR for 78 Byte frames using single trial\
-| | ... | throughput test.
-| | [Tags] | 1_THREAD_NOHTT_RXQUEUES_1 | SINGLE_THREAD | NDR | LISP_IPv6oIPv4
-| | ${framesize}= | Set Variable | 78
-| | ${duration}= | Set Variable | 10
+| | ... | throughput test at 2x 1.75mpps.
+| | [Tags] | 78B | 1T1C | STHREAD
+| | ${framesize}= | Set Variable | ${78}
 | | ${rate}= | Set Variable | 1.75mpps
-| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Add No Multi Seg to all DUTs
-| | And   Apply startup configuration on all VPP DUTs
-| | When Lisp IPv6 over IPv4 forwarding initialized in a 3-node circular topology
-| | ...  | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
-| | ...  | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
-| | And  Set up Lisp topology
-| | ...  | ${dut1} | ${dut1_if2} | ${NONE}
-| | ...  | ${dut2} | ${dut2_if1} | ${NONE}
-| | ...  | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
-| | ...  | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-IPv6
+| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology
+| | And Add PCI devices to DUTs in 3-node single link topology
+| | And Add no multi seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology
+| | ... | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
+| | ... | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
+| | And Configure LISP topology in 3-node circular topology
+| | ... | ${dut1} | ${dut1_if2} | ${NONE}
+| | ... | ${dut2} | ${dut2_if1} | ${NONE}
+| | ... | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
+| | ... | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | ${traffic_profile}
 
-| TC02: Verify 1460B ref-NDR at 2x 720kpps - DUT IPv6oIPv4 - 1thread 1core 1rxq
+| tc02-1460B-1t1c-ethip6lispip4-ip6base-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs LISP tunnel config with 1 thread, 1 phy core,\
 | | ... | 1 receive queue per NIC port.
 | | ... | [Ver] Verify ref-NDR for 1460 Byte frames using single trial\
-| | ... | throughput test.
-| | [Tags] | 1_THREAD_NOHTT_RXQUEUES_1 | SINGLE_THREAD | NDR | LISP_IPv6oIPv4
-| | ${framesize}= | Set Variable | 1460
-| | ${duration}= | Set Variable | 10
+| | ... | throughput test at 2x 720000pps.
+| | [Tags] | 1460B | 1T1C | STHREAD
+| | ${framesize}= | Set Variable | ${1460}
 | | ${rate}= | Set Variable | 720000pps
-| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Add No Multi Seg to all DUTs
-| | And   Apply startup configuration on all VPP DUTs
-| | When Lisp IPv6 over IPv4 forwarding initialized in a 3-node circular topology
-| | ...  | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
-| | ...  | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
-| | And  Set up Lisp topology
-| | ...  | ${dut1} | ${dut1_if2} | ${NONE}
-| | ...  | ${dut2} | ${dut2_if1} | ${NONE}
-| | ...  | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
-| | ...  | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-IPv6
+| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology
+| | And Add PCI devices to DUTs in 3-node single link topology
+| | And Add no multi seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology
+| | ... | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
+| | ... | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
+| | And Configure LISP topology in 3-node circular topology
+| | ... | ${dut1} | ${dut1_if2} | ${NONE}
+| | ... | ${dut2} | ${dut2_if1} | ${NONE}
+| | ... | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
+| | ... | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | ${traffic_profile}
 
-| TC03: Verify 9000B ref-NDR at 2x 120kpps - DUT IPv6oIPv4 - 1thread 1core 1rxq
+| tc03-9000B-1t1c-ethip6lispip4-ip6base-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs LISP tunnel config with 1 thread, 1 phy core,\
 | | ... | 1 receive queue per NIC port.
 | | ... | [Ver] Verify ref-NDR for 9000 Byte frames using single trial\
-| | ... | throughput test.
-| | [Tags] | 1_THREAD_NOHTT_RXQUEUES_1 | SINGLE_THREAD | NDR | LISP_IPv6oIPv4
-| | ${framesize}= | Set Variable | 9000
-| | ${duration}= | Set Variable | 10
+| | ... | throughput test at 2x 120000pps.
+| | [Tags] | 9000B | 1T1C | STHREAD
+| | ${framesize}= | Set Variable | ${9000}
 | | ${rate}= | Set Variable | 120000pps
-| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Apply startup configuration on all VPP DUTs
-| | When Lisp IPv6 over IPv4 forwarding initialized in a 3-node circular topology
-| | ...  | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
-| | ...  | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
-| | And  Set up Lisp topology
-| | ...  | ${dut1} | ${dut1_if2} | ${NONE}
-| | ...  | ${dut2} | ${dut2_if1} | ${NONE}
-| | ...  | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
-| | ...  | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-IPv6
+| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology
+| | And Add PCI devices to DUTs in 3-node single link topology
+| | And Apply startup configuration on all VPP DUTs
+| | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology
+| | ... | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
+| | ... | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
+| | And Configure LISP topology in 3-node circular topology
+| | ... | ${dut1} | ${dut1_if2} | ${NONE}
+| | ... | ${dut2} | ${dut2_if1} | ${NONE}
+| | ... | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
+| | ... | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | ${traffic_profile}
 
-| TC04: Verify 78B ref-NDR at 2x 3.42Mpps - DUT IPv6oIPv4 - 2thread 2core 1rxq
+| tc04-78B-2t2c-ethip6lispip4-ip6base-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs LISP tunnel config with 2 threads, 2 phy cores,\
 | | ... | 1 receive queue per NIC port.
 | | ... | [Ver] Verify ref-NDR for 78 Byte frames using single trial\
-| | ... | throughput test.
-| | [Tags] | 2_THREAD_NOHTT_RXQUEUES_1 | MULTI_THREAD | NDR | LISP_IPv6oIPv4
-| | ${framesize}= | Set Variable | 78
-| | ${duration}= | Set Variable | 10
+| | ... | throughput test at 2x 3.42mpps.
+| | [Tags] | 78B | 2T2C | MTHREAD
+| | ${framesize}= | Set Variable | ${78}
 | | ${rate}= | Set Variable | 3.42mpps
-| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Add No Multi Seg to all DUTs
-| | And   Apply startup configuration on all VPP DUTs
-| | When Lisp IPv6 over IPv4 forwarding initialized in a 3-node circular topology
-| | ...  | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
-| | ...  | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
-| | And  Set up Lisp topology
-| | ...  | ${dut1} | ${dut1_if2} | ${NONE}
-| | ...  | ${dut2} | ${dut2_if1} | ${NONE}
-| | ...  | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
-| | ...  | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-IPv6
+| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology
+| | And Add PCI devices to DUTs in 3-node single link topology
+| | And Add no multi seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology
+| | ... | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
+| | ... | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
+| | And Configure LISP topology in 3-node circular topology
+| | ... | ${dut1} | ${dut1_if2} | ${NONE}
+| | ... | ${dut2} | ${dut2_if1} | ${NONE}
+| | ... | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
+| | ... | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | ${traffic_profile}
 
-| TC05: Verify 1460B ref-NDR at 2x 720kpps - DUT IPv6oIPv4 - 2thread 2core 1rxq
+| tc05-1460B-2t2c-ethip6lispip4-ip6base-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs LISP tunnel config with 2 threads, 2 phy cores,\
 | | ... | 1 receive queue per NIC port.
 | | ... | [Ver] Verify ref-NDR for 1460 Byte frames using single trial\
-| | ... | throughput test.
-| | [Tags] | 2_THREAD_NOHTT_RXQUEUES_1 | MULTI_THREAD | NDR | LISP_IPv6oIPv4
-| | ${framesize}= | Set Variable | 1460
-| | ${duration}= | Set Variable | 10
+| | ... | throughput test at 2x 720000pps.
+| | [Tags] | 1460B | 2T2C | MTHREAD
+| | ${framesize}= | Set Variable | ${1460}
 | | ${rate}= | Set Variable | 720000pps
-| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Add No Multi Seg to all DUTs
-| | And   Apply startup configuration on all VPP DUTs
-| | When Lisp IPv6 over IPv4 forwarding initialized in a 3-node circular topology
-| | ...  | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
-| | ...  | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
-| | And  Set up Lisp topology
-| | ...  | ${dut1} | ${dut1_if2} | ${NONE}
-| | ...  | ${dut2} | ${dut2_if1} | ${NONE}
-| | ...  | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
-| | ...  | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-IPv6
+| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology
+| | And Add PCI devices to DUTs in 3-node single link topology
+| | And Add no multi seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology
+| | ... | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
+| | ... | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
+| | And Configure LISP topology in 3-node circular topology
+| | ... | ${dut1} | ${dut1_if2} | ${NONE}
+| | ... | ${dut2} | ${dut2_if1} | ${NONE}
+| | ... | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
+| | ... | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | ${traffic_profile}
 
-| TC06: Verify 9000B ref-NDR at 2x 120kpps - DUT IPv6oIPv4 - 2thread 2core 1rxq
+| tc06-9000B-2t2c-ethip6lispip4-ip6base-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs LISP tunnel config with 2 threads, 2 phy cores,\
 | | ... | 1 receive queue per NIC port.
 | | ... | [Ver] Verify ref-NDR for 9000 Byte frames using single trial\
-| | ... | throughput test.
-| | [Tags] | 2_THREAD_NOHTT_RXQUEUES_1 | MULTI_THREAD | NDR | LISP_IPv6oIPv4
-| | ${framesize}= | Set Variable | 9000
-| | ${duration}= | Set Variable | 10
+| | ... | throughput test at 2x 120000pps.
+| | [Tags] | 9000B | 2T2C | MTHREAD
+| | ${framesize}= | Set Variable | ${9000}
 | | ${rate}= | Set Variable | 120000pps
-| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Apply startup configuration on all VPP DUTs
-| | When Lisp IPv6 over IPv4 forwarding initialized in a 3-node circular topology
-| | ...  | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
-| | ...  | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
-| | And  Set up Lisp topology
-| | ...  | ${dut1} | ${dut1_if2} | ${NONE}
-| | ...  | ${dut2} | ${dut2_if1} | ${NONE}
-| | ...  | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
-| | ...  | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-IPv6
+| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology
+| | And Add PCI devices to DUTs in 3-node single link topology
+| | And Apply startup configuration on all VPP DUTs
+| | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology
+| | ... | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
+| | ... | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
+| | And Configure LISP topology in 3-node circular topology
+| | ... | ${dut1} | ${dut1_if2} | ${NONE}
+| | ... | ${dut2} | ${dut2_if1} | ${NONE}
+| | ... | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
+| | ... | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | ${traffic_profile}
 
-| TC07: Verify 78B ref-NDR at 2x 3.42Mpps - DUT IPv6oIPv4 - 4thread 4core 2rxq
+| tc07-78B-4t4c-ethip6lispip4-ip6base-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs LISP tunnel config with 4 threads, 4 phy cores,\
 | | ... | 2 receive queues per NIC port.
 | | ... | [Ver] Verify ref-NDR for 78 Byte frames using single trial\
-| | ... | throughput test.
-| | [Tags] | 4_THREAD_NOHTT_RXQUEUES_2 | MULTI_THREAD | NDR | LISP_IPv6oIPv4
-| | ${framesize}= | Set Variable | 78
-| | ${duration}= | Set Variable | 10
+| | ... | throughput test at 2x 3.42mpps.
+| | [Tags] | 78B | 4T4C | MTHREAD
+| | ${framesize}= | Set Variable | ${78}
 | | ${rate}= | Set Variable | 3.42mpps
-| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Add No Multi Seg to all DUTs
-| | And   Apply startup configuration on all VPP DUTs
-| | When Lisp IPv6 over IPv4 forwarding initialized in a 3-node circular topology
-| | ...  | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
-| | ...  | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
-| | And  Set up Lisp topology
-| | ...  | ${dut1} | ${dut1_if2} | ${NONE}
-| | ...  | ${dut2} | ${dut2_if1} | ${NONE}
-| | ...  | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
-| | ...  | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-IPv6
+| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology
+| | And Add PCI devices to DUTs in 3-node single link topology
+| | And Add no multi seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology
+| | ... | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
+| | ... | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
+| | And Configure LISP topology in 3-node circular topology
+| | ... | ${dut1} | ${dut1_if2} | ${NONE}
+| | ... | ${dut2} | ${dut2_if1} | ${NONE}
+| | ... | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
+| | ... | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | ${traffic_profile}
 
-| TC08: Verify 1460B ref-NDR at 2x 720Kpps - DUT IPv6oIPv4 - 4thread 4core 2rxq
+| tc08-1460B-4t4c-ethip6lispip4-ip6base-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs LISP tunnel config with 4 threads, 4 phy cores,\
 | | ... | 2 receive queues per NIC port.
 | | ... | [Ver] Verify ref-NDR for 1460 Byte frames using single trial\
-| | ... | throughput test.
-| | [Tags] | 4_THREAD_NOHTT_RXQUEUES_2 | MULTI_THREAD | NDR | LISP_IPv6oIPv4
-| | ${framesize}= | Set Variable | 1460
-| | ${duration}= | Set Variable | 10
+| | ... | throughput test at 2x 720000pps.
+| | [Tags] | 1460B | 4T4C | MTHREAD
+| | ${framesize}= | Set Variable | ${1460}
 | | ${rate}= | Set Variable | 720000pps
-| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Add No Multi Seg to all DUTs
-| | And   Apply startup configuration on all VPP DUTs
-| | When Lisp IPv6 over IPv4 forwarding initialized in a 3-node circular topology
-| | ...  | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
-| | ...  | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
-| | And  Set up Lisp topology
-| | ...  | ${dut1} | ${dut1_if2} | ${NONE}
-| | ...  | ${dut2} | ${dut2_if1} | ${NONE}
-| | ...  | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
-| | ...  | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-IPv6
+| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology
+| | And Add PCI devices to DUTs in 3-node single link topology
+| | And Add no multi seg to all DUTs
+| | And Apply startup configuration on all VPP DUTs
+| | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology
+| | ... | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
+| | ... | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
+| | And Configure LISP topology in 3-node circular topology
+| | ... | ${dut1} | ${dut1_if2} | ${NONE}
+| | ... | ${dut2} | ${dut2_if1} | ${NONE}
+| | ... | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
+| | ... | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | ${traffic_profile}
 
-| TC09: Verify 9000B ref-NDR at 2x 120Kpps - DUT IPv6oIPv4 - 4thread 4core 2rxq
+| tc09-9000B-4t4c-ethip6lispip4-ip6base-ndrchk
 | | [Documentation]
 | | ... | [Cfg] DUT runs LISP tunnel config with 4 threads, 4 phy cores,\
 | | ... | 2 receive queues per NIC port.
 | | ... | [Ver] Verify ref-NDR for 9000 Byte frames using single trial\
-| | ... | throughput test.
-| | [Tags] | 4_THREAD_NOHTT_RXQUEUES_2 | MULTI_THREAD | NDR | LISP_IPv6oIPv4
-| | ${framesize}= | Set Variable | 9000
-| | ${duration}= | Set Variable | 10
+| | ... | throughput test at 2x 120000pps.
+| | [Tags] | 9000B | 4T4C | MTHREAD
+| | ${framesize}= | Set Variable | ${9000}
 | | ${rate}= | Set Variable | 120000pps
-| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo
-| | And   Add PCI devices to DUTs from 3-node single link topology
-| | And   Apply startup configuration on all VPP DUTs
-| | When Lisp IPv6 over IPv4 forwarding initialized in a 3-node circular topology
-| | ...  | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
-| | ...  | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
-| | And  Set up Lisp topology
-| | ...  | ${dut1} | ${dut1_if2} | ${NONE}
-| | ...  | ${dut2} | ${dut2_if1} | ${NONE}
-| | ...  | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
-| | ...  | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
-| | Then Traffic should pass with no loss | ${duration} | ${rate}
-| | ...                                   | ${framesize} | 3-node-IPv6
+| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology
+| | And Add PCI devices to DUTs in 3-node single link topology
+| | And Apply startup configuration on all VPP DUTs
+| | When Initialize LISP IPv6 over IPv4 forwarding in 3-node circular topology
+| | ... | ${dut1_to_dut2_ip6o4} | ${dut1_to_tg_ip6o4} | ${dut2_to_dut1_ip6o4}
+| | ... | ${dut2_to_tg_ip6o4} | ${tg_prefix6o4} | ${dut_prefix6o4}
+| | And Configure LISP topology in 3-node circular topology
+| | ... | ${dut1} | ${dut1_if2} | ${NONE}
+| | ... | ${dut2} | ${dut2_if1} | ${NONE}
+| | ... | ${duts_locator_set} | ${dut1_ip6o4_eid} | ${dut2_ip6o4_eid}
+| | ... | ${dut1_ip6o4_static_adjacency} | ${dut2_ip6o4_static_adjacency}
+| | Then Traffic should pass with no loss | ${perf_trial_duration} | ${rate}
+| | ... | ${framesize} | ${traffic_profile}