CSIT-1097: Migrate vm_vhost to NDRPDR and edit MRR
[csit.git] / tests / vpp / perf / vm_vhost / 10ge2p1x520-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdrdisc.robot
diff --git a/tests/vpp/perf/vm_vhost/10ge2p1x520-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdrdisc.robot b/tests/vpp/perf/vm_vhost/10ge2p1x520-dot1q-l2xcbase-eth-2vhostvr1024-1vm-ndrpdrdisc.robot
deleted file mode 100644 (file)
index 1dd4cac..0000000
+++ /dev/null
@@ -1,685 +0,0 @@
-# Copyright (c) 2017 Cisco and/or its affiliates.
-# Licensed under the Apache License, Version 2.0 (the "License");
-# you may not use this file except in compliance with the License.
-# You may obtain a copy of the License at:
-#
-#     http://www.apache.org/licenses/LICENSE-2.0
-#
-# Unless required by applicable law or agreed to in writing, software
-# distributed under the License is distributed on an "AS IS" BASIS,
-# WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
-# See the License for the specific language governing permissions and
-# limitations under the License.
-
-*** Settings ***
-| Resource | resources/libraries/robot/performance/performance_setup.robot
-| Library | resources.libraries.python.NodePath
-| ...
-| Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDRDISC
-| ... | NIC_Intel-X520-DA2 | DOT1Q | L2XCFWD | BASE | VHOST | VM | VHOST_1024
-| ...
-| Suite Setup | Set up 3-node performance topology with DUT's NIC model
-| ... | L2 | Intel-X520-DA2
-| Suite Teardown | Tear down 3-node performance topology
-| ...
-| Test Setup | Set up performance test
-| Test Teardown | Tear down performance test with vhost and VM with dpdk-testpmd
-| ... | ${min_rate}pps | ${framesize} | ${traffic_profile}
-| ... | dut1_node=${dut1} | dut1_vm_refs=${dut1_vm_refs}
-| ... | dut2_node=${dut2} | dut2_vm_refs=${dut2_vm_refs}
-| ...
-| Documentation | *RFC2544: Pkt throughput L2XC test cases with vhost*
-| ...
-| ... | *[Top] Network Topologies:* TG-DUT1-DUT2-TG 3-node circular topology
-| ... | with single links between nodes.
-| ... | *[Enc] Packet Encapsulations:* Eth-IPv4 for L2 cross connect. 802.1q
-| ... | tagging is applied on link between DUT1 and DUT2.
-| ... | *[Cfg] DUT configuration:* DUT1 and DUT2 are configured with L2 cross-
-| ... | connect. Qemu Guest is connected to VPP via vhost-user interfaces.
-| ... | Guest is running DPDK testpmd interconnecting vhost-user interfaces
-| ... | using 5 cores pinned to cpus 5-9 and 2048M memory. Testpmd is using
-| ... | socket-mem=1024M (512x2M hugepages), 5 cores (1 main core and 4 cores
-| ... | dedicated for io), forwarding mode is set to io, rxd/txd=256,
-| ... | burst=64. DUT1, DUT2 are tested with 2p10GE NIC X520 Niantic by Intel.
-| ... | *[Ver] TG verification:* TG finds and reports throughput NDR (Non Drop
-| ... | Rate) with zero packet loss tolerance or throughput PDR (Partial Drop
-| ... | Rate) with non-zero packet loss tolerance (LT) expressed in percentage
-| ... | of packets transmitted. NDR and PDR are discovered for different
-| ... | Ethernet L2 frame sizes using either binary search or linear search
-| ... | algorithms with configured starting rate and final step that determines
-| ... | throughput measurement resolution. Test packets are generated by TG on
-| ... | links to DUTs. TG traffic profile contains two L3 flow-groups
-| ... | (flow-group per direction, 253 flows per flow-group) with all packets
-| ... | containing Ethernet header, IPv4 header with IP protocol=61 and static
-| ... | payload. MAC addresses are matching MAC addresses of the TG node
-| ... | interfaces.
-| ... | *[Ref] Applicable standard specifications:* RFC2544.
-
-*** Variables ***
-| ${perf_qemu_qsz}= | 1024
-| ${subid}= | 10
-| ${tag_rewrite}= | pop-1
-| ${vlan_overhead}= | ${4}
-# Socket names
-| ${sock1}= | /tmp/sock-1
-| ${sock2}= | /tmp/sock-2
-# X520-DA2 bandwidth limit
-| ${s_limit}= | ${10000000000}
-# Traffic profile:
-| ${traffic_profile}= | trex-sl-3n-ethip4-ip4src254
-
-*** Test Cases ***
-| tc01-64B-1t1c-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 1 phy core,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Find NDR for 64 Byte frames using binary search start at 10GE\
-| | ... | linerate, step 10kpps.
-| | ...
-| | [Tags] | 64B | 1C | NDRDISC
-| | ...
-| | ${framesize}= | Set Variable | ${64}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${framesize + ${vlan_overhead}}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 1
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold}
-
-| tc02-64B-1t1c-eth-l2xcbase-eth-2vhostvr1024-1vm-pdrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2BD switching config with 1 phy core,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Find PDR for 64 Byte frames using binary search start at 10GE\
-| | ... | linerate, step 10kpps, LT=0.5%.
-| | ...
-| | [Tags] | 64B | 1C | PDRDISC | SKIP_PATCH
-| | ...
-| | ${framesize}= | Set Variable | ${64}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${framesize + ${vlan_overhead}}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 1
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold} | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
-
-| tc03-1518B-1t1c-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 1 phy core,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Find NDR for 1518 Byte frames using binary search start at 10GE\
-| | ... | linerate, step 10kpps.
-| | ...
-| | [Tags] | 1518B | 1C | NDRDISC
-| | ...
-| | ${framesize}= | Set Variable | ${1518}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${framesize + ${vlan_overhead}}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 1
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold}
-
-| tc04-1518B-1t1c-eth-l2xcbase-eth-2vhostvr1024-1vm-pdrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2BD switching config with 1 phy core,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Find PDR for 1518 Byte frames using binary search start at 10GE\
-| | ... | linerate, step 10kpps, LT=0.5%.
-| | ...
-| | [Tags] | 1518B | 1C | PDRDISC | SKIP_PATCH
-| | ...
-| | ${framesize}= | Set Variable | ${1518}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${framesize + ${vlan_overhead}}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 1
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold} | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
-
-| tc05-IMIX-1t1c-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2BD switching config with 1 phy core,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Find NDR for IMIX_v4_1 framesize using binary search start at\
-| | ... | 10GE linerate, step 10kpps.
-| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B)
-| | ...
-| | [Tags] | IMIX | 1C | NDRDISC
-| | ...
-| | ${framesize}= | Set Variable | IMIX_v4_1
-| | ${avg_framesize}= | Set Variable | ${357.833}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${avg_framesize}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 1
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold}
-
-| tc06-IMIX-1t1c-eth-l2xcbase-eth-2vhostvr1024-1vm-pdrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2BD switching config with 1 phy core,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Find PDR for IMIX_v4_1 framesize using binary search start at\
-| | ... | 10GE linerate, step 10kpps, LT=0.5%.
-| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B)
-| | ...
-| | [Tags] | IMIX | 1C | PDRDISC | SKIP_PATCH
-| | ...
-| | ${framesize}= | Set Variable | IMIX_v4_1
-| | ${avg_framesize}= | Set Variable | ${357.833}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${avg_framesize}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 1
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold} | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
-
-| tc07-64B-2t2c-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 2 phy cores,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Find NDR for 64 Byte frames using binary search start at 10GE\
-| | ... | linerate, step 10kpps.
-| | ...
-| | [Tags] | 64B | 2C | NDRDISC
-| | ...
-| | ${framesize}= | Set Variable | ${64}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${framesize + ${vlan_overhead}}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 2
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold}
-
-| tc08-64B-2t2c-eth-l2xcbase-eth-2vhostvr1024-1vm-pdrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2BD switching config with 2 phy cores,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Find PDR for 64 Byte frames using binary search start at 10GE\
-| | ... | linerate, step 10kpps, LT=0.5%.
-| | ...
-| | [Tags] | 64B | 2C | PDRDISC | SKIP_PATCH
-| | ...
-| | ${framesize}= | Set Variable | ${64}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${framesize + ${vlan_overhead}}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 2
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold} | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
-
-| tc09-1518B-2t2c-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 2 phy cores,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Find NDR for 1518 Byte frames using binary search start at 10GE\
-| | ... | linerate, step 10kpps.
-| | ...
-| | [Tags] | 1518B | 2C | NDRDISC | SKIP_PATCH
-| | ...
-| | ${framesize}= | Set Variable | ${1518}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${framesize + ${vlan_overhead}}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 2
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold}
-
-| tc10-1518B-2t2c-eth-l2xcbase-eth-2vhostvr1024-1vm-pdrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2BD switching config with 2 phy cores,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Find PDR for 1518 Byte frames using binary search start at 10GE\
-| | ... | linerate, step 10kpps, LT=0.5%.
-| | ...
-| | [Tags] | 1518B | 2C | PDRDISC | SKIP_PATCH
-| | ...
-| | ${framesize}= | Set Variable | ${1518}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${framesize + ${vlan_overhead}}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 2
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold} | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
-
-| tc11-IMIX-2t2c-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2BD switching config with 2 phy cores,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Find NDR for IMIX_v4_1 framesize using binary search start at\
-| | ... | 10GE linerate, step 10kpps.
-| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B)
-| | ...
-| | [Tags] | IMIX | 2C | NDRDISC | SKIP_PATCH
-| | ...
-| | ${framesize}= | Set Variable | IMIX_v4_1
-| | ${avg_framesize}= | Set Variable | ${357.833}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${avg_framesize}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 2
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold}
-
-| tc12-IMIX-2t2c-eth-l2xcbase-eth-2vhostvr1024-1vm-pdrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2BD switching config with 2 phy cores,\
-| | ... | 1 receive queue per NIC port.
-| | ... | [Ver] Find PDR for IMIX_v4_1 framesize using binary search start at\
-| | ... | 10GE linerate, step 10kpps, LT=0.5%.
-| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B)
-| | ...
-| | [Tags] | IMIX | 2C | PDRDISC | SKIP_PATCH
-| | ...
-| | ${framesize}= | Set Variable | IMIX_v4_1
-| | ${avg_framesize}= | Set Variable | ${357.833}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${avg_framesize}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 2
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold} | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
-
-| tc13-64B-4t4c-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 4 phy cores,\
-| | ... | 2 receive queues per NIC port.
-| | ... | [Ver] Find NDR for 64 Byte frames using binary search start at 10GE\
-| | ... | linerate, step 10kpps.
-| | ...
-| | [Tags] | 64B | 4C | NDRDISC
-| | ...
-| | ${framesize}= | Set Variable | ${64}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${framesize + ${vlan_overhead}}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 4
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold}
-
-| tc14-64B-4t4c-eth-l2xcbase-eth-2vhostvr1024-1vm-pdrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 4 phy cores,\
-| | ... | 2 receive queues per NIC port.
-| | ... | [Ver] Find PDR for 64 Byte frames using binary search start at 10GE\
-| | ... | linerate, step 10kpps, LT=0.5%.
-| | ...
-| | [Tags] | 64B | 4C | PDRDISC | SKIP_PATCH
-| | ...
-| | ${framesize}= | Set Variable | ${64}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${framesize + ${vlan_overhead}}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 4
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold} | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
-
-| tc15-1518B-4t4c-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 4 phy cores,\
-| | ... | 2 receive queues per NIC port.
-| | ... | [Ver] Find NDR for 1518 Byte frames using binary search start at 10GE\
-| | ... | linerate, step 10kpps.
-| | ...
-| | [Tags] | 1518B | 4C | NDRDISC | SKIP_PATCH
-| | ...
-| | ${framesize}= | Set Variable | ${1518}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${framesize + ${vlan_overhead}}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 4
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold}
-
-| tc16-1518B-4t4c-eth-l2xcbase-eth-2vhostvr1024-1vm-pdrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 4 phy cores,\
-| | ... | 2 receive queues per NIC port.
-| | ... | [Ver] Find PDR for 1518 Byte frames using binary search start at 10GE\
-| | ... | linerate, step 10kpps, LT=0.5%.
-| | ...
-| | [Tags] | 1518B | 4C | PDRDISC | SKIP_PATCH
-| | ...
-| | ${framesize}= | Set Variable | ${1518}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${framesize + ${vlan_overhead}}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 4
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold} | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}
-
-| tc17-IMIX-4t4c-eth-l2xcbase-eth-2vhostvr1024-1vm-ndrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 4 phy cores,\
-| | ... | 2 receive queues per NIC port.
-| | ... | [Ver] Find NDR for IMIX_v4_1 framesize using binary search start at\
-| | ... | 10GE linerate, step 10kpps.
-| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B)
-| | ...
-| | [Tags] | IMIX | 4C | NDRDISC | SKIP_PATCH
-| | ...
-| | ${framesize}= | Set Variable | IMIX_v4_1
-| | ${avg_framesize}= | Set Variable | ${357.833}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${avg_framesize}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 4
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find NDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold}
-
-| tc18-IMIX-4t4c-eth-l2xcbase-eth-2vhostvr1024-1vm-pdrdisc
-| | [Documentation]
-| | ... | [Cfg] DUT runs L2XC switching config with 4 phy cores,\
-| | ... | 2 receive queues per NIC port.
-| | ... | [Ver] Find PDR for IMIX_v4_1 framesize using binary search start at\
-| | ... | 10GE linerate, step 10kpps, LT=0.5%.
-| | ... | IMIX_v4_1 = (28x64B; 16x570B; 4x1518B)
-| | ...
-| | [Tags] | IMIX | 4C | PDRDISC | SKIP_PATCH
-| | ...
-| | ${framesize}= | Set Variable | IMIX_v4_1
-| | ${avg_framesize}= | Set Variable | ${357.833}
-| | ${min_rate}= | Set Variable | ${10000}
-| | ${max_rate}= | Calculate pps | ${s_limit} | ${avg_framesize}
-| | ${binary_min}= | Set Variable | ${min_rate}
-| | ${binary_max}= | Set Variable | ${max_rate}
-| | ${threshold}= | Set Variable | ${min_rate}
-| | ${dut1_vm_refs}= | Create Dictionary
-| | ${dut2_vm_refs}= | Create Dictionary
-| | Given Add worker threads and rxqueues to all DUTs | 4
-| | And Add PCI devices to all DUTs
-| | And Add no multi seg to all DUTs
-| | And Apply startup configuration on all VPP DUTs
-| | When Initialize L2 xconnect with Vhost-User and VLAN in 3-node circular topology
-| | ... | ${sock1} | ${sock2} | ${subid} | ${tag_rewrite}
-| | ${vm1}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut1} | ${sock1} | ${sock2} | DUT1_VM1
-| | Set To Dictionary | ${dut1_vm_refs} | DUT1_VM1 | ${vm1}
-| | ${vm2}= | And Configure guest VM with dpdk-testpmd connected via vhost-user
-| | ... | ${dut2} | ${sock1} | ${sock2} | DUT2_VM1
-| | Set To Dictionary | ${dut2_vm_refs} | DUT2_VM1 | ${vm2}
-| | Then Find PDR using binary search and pps | ${framesize} | ${binary_min}
-| | ... | ${binary_max} | ${traffic_profile}
-| | ... | ${min_rate} | ${max_rate} | ${threshold} | ${perf_pdr_loss_acceptance}
-| | ... | ${perf_pdr_loss_acceptance_type}