Add New Skylake topology files
[csit.git] / topologies / available / lf_3n_hsw_testbed1.yaml
diff --git a/topologies/available/lf_3n_hsw_testbed1.yaml b/topologies/available/lf_3n_hsw_testbed1.yaml
new file mode 100644 (file)
index 0000000..fcd9208
--- /dev/null
@@ -0,0 +1,285 @@
+---
+metadata:
+  version: 0.1
+  schema:
+    - resources/topology_schemas/3_node_topology.sch.yaml
+    - resources/topology_schemas/topology.sch.yaml
+  tags: [hw, 3-node]
+
+nodes:
+  TG:
+    type: TG
+    subtype: TREX
+    host: "10.30.51.16"
+    arch: x86_64
+    port: 22
+    username: testuser
+    password: Csit1234
+    interfaces:
+      port1:
+        # t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:37:1f:48"
+        pci_address: "0000:02:00.0"
+        ip4_address: "172.16.10.2"
+        driver: i40e
+        link: link1
+        model: Intel-XL710
+      port2:
+        # t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:37:1f:4d"
+        pci_address: "0000:02:00.1"
+        ip4_address: "172.16.20.2"
+        driver: i40e
+        link: link2
+        model: Intel-XL710
+      port3:
+        # t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ee:a0"
+        pci_address: "0000:05:00.0"
+        ip4_address: "172.16.30.2"
+        driver: i40e
+        link: link3
+        model: Intel-X710
+      port4:
+        # t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ee:a1"
+        pci_address: "0000:05:00.1"
+        ip4_address: "172.16.40.2"
+        driver: i40e
+        link: link4
+        model: Intel-X710
+      port5:
+        # t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ed:50"
+        pci_address: "0000:07:00.0"
+        ip4_address: "172.16.50.2"
+        driver: i40e
+        link: link5
+        model: Intel-X710
+      port6:
+        # t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ed:51"
+        pci_address: "0000:07:00.1"
+        ip4_address: "172.16.60.2"
+        driver: i40e
+        link: link6
+        model: Intel-X710
+      port7:
+        # t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:3a:af:40"
+        pci_address: "0000:86:00.0"
+        ip4_address: "172.16.70.2"
+        driver: i40e
+        link: link7
+        model: Intel-XL710
+      port8:
+        # t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:3a:af:41"
+        pci_address: "0000:86:00.1"
+        ip4_address: "172.16.80.2"
+        driver: i40e
+        link: link8
+        model: Intel-XL710
+      port9:
+        # t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ee:2c"
+        pci_address: "0000:88:00.0"
+        ip4_address: "172.16.90.2"
+        driver: i40e
+        link: link9
+        model: Intel-X710
+      port10:
+        # t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ee:2d"
+        pci_address: "0000:88:00.1"
+        ip4_address: "172.16.100.2"
+        driver: i40e
+        link: link10
+        model: Intel-X710
+      port11:
+        # t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ed:a4"
+        pci_address: "0000:84:00.0"
+        ip4_address: "172.16.110.1"
+        driver: i40e
+        link: link11
+        model: Intel-X710
+      port12:
+        # t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ed:a5"
+        pci_address: "0000:84:00.1"
+        ip4_address: "172.16.110.2"
+        driver: i40e
+        link: link11
+        model: Intel-X710
+  DUT1:
+    type: DUT
+    host: "10.30.51.17"
+    arch: x86_64
+    port: 22
+    username: testuser
+    password: Csit1234
+    cryptodev: 0000:86:00.0
+    uio_driver: igb_uio
+    honeycomb:
+      user: admin
+      passwd: admin
+      port: 8183
+      netconf_port: 2831
+    interfaces:
+      port1:
+        # t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
+        mac_address: "90:e2:ba:b5:0a:18"
+        pci_address: "0000:0a:00.0"
+        ip4_address: "172.17.21.1"
+        link: link21
+        model: Intel-X520-DA2
+      port2:
+        # t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
+        mac_address: "90:e2:ba:b5:0a:19"
+        pci_address: "0000:0a:00.1"
+        ip4_address: "172.16.30.1"
+        link: link3
+        model: Intel-X520-DA2
+      port3:
+        # t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
+        mac_address: "04:62:73:8c:c3:0f"
+        pci_address: "0000:13:00.0"
+        ip4_address: "172.17.22.1"
+        link: link22
+        model: Cisco-VIC-1385
+      port4:
+        # t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
+        mac_address: "04:62:73:8c:c3:10"
+        pci_address: "0000:14:00.0"
+        ip4_address: "172.16.10.1"
+        link: link1
+        model: Cisco-VIC-1385
+      port5:
+        # t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:37:20:48"
+        pci_address: "0000:88:00.0"
+        ip4_address: "172.17.23.1"
+        link: link23
+        model: Intel-XL710
+      port6:
+        # t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:37:20:49"
+        pci_address: "0000:88:00.1"
+        ip4_address: "172.16.70.1"
+        link: link7
+        model: Intel-XL710
+      port7:
+        # t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ee:c4"
+        pci_address: "0000:8a:00.0"
+        ip4_address: "172.17.24.1"
+        link: link24
+        model: Intel-X710
+      port8:
+        # t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ee:c5"
+        pci_address: "0000:8a:00.1"
+        ip4_address: "172.16.90.1"
+        link: link9
+        model: Intel-X710
+      port9:
+        # t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
+        mac_address: "00:fe:c8:e4:d0:1b"
+        pci_address: "0000:06:00.0"
+        ip4_address: "172.17.25.1"
+        link: link25
+        model: Cisco-VIC-1227
+      port10:
+        # t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
+        mac_address: "00:fe:c8:e4:d0:1c"
+        pci_address: "0000:07:00.0"
+        ip4_address: "172.16.50.1"
+        link: link5
+        model: Cisco-VIC-1227
+  DUT2:
+    type: DUT
+    host: "10.30.51.18"
+    arch: x86_64
+    port: 22
+    username: testuser
+    password: Csit1234
+    cryptodev: 0000:86:00.0
+    uio_driver: igb_uio
+    honeycomb:
+      user: admin
+      passwd: admin
+      port: 8183
+      netconf_port: 2831
+    interfaces:
+      port1:
+        # t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
+        mac_address: "90:e2:ba:b5:05:e4"
+        pci_address: "0000:0a:00.0"
+        ip4_address: "172.16.40.1"
+        link: link4
+        model: Intel-X520-DA2
+      port2:
+        # t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
+        mac_address: "90:e2:ba:b5:05:e5"
+        pci_address: "0000:0a:00.1"
+        ip4_address: "172.17.21.2"
+        link: link21
+        model: Intel-X520-DA2
+      port3:
+        # t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
+        mac_address: "d8:b1:90:19:41:69"
+        pci_address: "0000:13:00.0"
+        ip4_address: "172.16.20.1"
+        link: link2
+        model: Cisco-VIC-1385
+      port4:
+        # t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
+        mac_address: "d8:b1:90:19:41:6a"
+        pci_address: "0000:15:00.0"
+        ip4_address: "172.17.22.2"
+        link: link22
+        model: Cisco-VIC-1385
+      port5:
+        # t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:35:78:e8"
+        pci_address: "0000:88:00.0"
+        ip4_address: "172.16.80.1"
+        link: link8
+        model: Intel-XL710
+      port6:
+        # t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:35:78:e9"
+        pci_address: "0000:88:00.1"
+        ip4_address: "172.17.23.2"
+        link: link23
+        model: Intel-XL710
+      port7:
+        # t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ef:94"
+        pci_address: "0000:8a:00.0"
+        ip4_address: "172.16.100.1"
+        link: link10
+        model: Intel-X710
+      port8:
+        # t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ef:95"
+        pci_address: "0000:8a:00.1"
+        ip4_address: "172.17.24.2"
+        link: link24
+        model: Intel-X710
+      port9:
+        # t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
+        mac_address: "00:fe:c8:e5:44:4c"
+        pci_address: "0000:06:00.0"
+        ip4_address: "172.16.60.1"
+        link: link6
+        model: Cisco-VIC-1227
+      port10:
+        # t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
+        mac_address: "00:fe:c8:e5:44:4d"
+        pci_address: "0000:07:00.0"
+        ip4_address: "172.17.25.2"
+        link: link25
+        model: Cisco-VIC-1227
+