X-Git-Url: https://gerrit.fd.io/r/gitweb?p=csit.git;a=blobdiff_plain;f=docs%2Flab%2Ftestbed_specifications.md;h=7d4f0e001aa186372cffb3d985dba383d8f5a1b4;hp=b12d42d22f7c40e4f1a289f88ddbb383f43e8130;hb=1b23beff6898a86280c65ec7c983e0fb92ff28bb;hpb=ddbfd9e68e81e77bd253c8b6cd81839ec3bd2715 diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index b12d42d22f..7d4f0e001a 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -1,58 +1,67 @@ - - - - [FD.io CSIT Testbed Specifications](#fdio-csit-testbed-specifications) - - [Testbeds Overview](#testbeds-overview) - - [Summary List](#summary-list) - - [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx) - - [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2) - - [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx) - - [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv) - - [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1) - - [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx) - - [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx) - - [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) - - [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell) - - [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds) - - [Server Management](#server-management) - - [Requirements](#requirements) - - [Addressing](#addressing) - - [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses) - - [Management VLAN IP Addresses](#management-vlan-ip-addresses) - - [Server Type Specification](#server-type-specification) - - [Server and Port Naming](#server-and-port-naming) - - [Testbeds Configuration](#testbeds-configuration) - - [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming) - - [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod) - - [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip) - - [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod) - - [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo) - - [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify) - - [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod) - - [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod) - - [3-Node-Rangeley (3n-rng) VERIFY](#3-node-rangeley-3n-rng-verify) - - [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip) - - [3-Node-Mcbin (3n-mcb) TODO](#3-node-mcbin-3n-mcb-todo) - - [Per Testbed Wiring](#per-testbed-wiring) - - [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod) - - [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip) - - [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod) - - [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo) - - [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify) - - [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod) - - [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod) - - [3-Node-Rangeley (3n-rng) TODO](#3-node-rangeley-3n-rng-todo) - - [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip) - - [3-Node-Mcbin (3n-mcb) WIP](#3-node-mcbin-3n-mcb-wip) - - [Inventory](#inventory) - - [Appliances](#appliances) - - [Arm Servers](#arm-servers) - - [Xeon and Atom Servers](#xeon-and-atom-servers) - - [Network Interface Cards](#network-interface-cards) - - [Pluggables and Cables](#pluggables-and-cables) - - [Other Parts](#other-parts) - - -## FD.io CSIT Testbed Specifications +# FD.io CSIT Testbed Specifications + +1. [Purpose](#purpose) +1. [Testbeds Overview](#testbeds-overview) + 1. [Summary List](#summary-list) + 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx) + 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2) + 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx) + 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx) + 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv) + 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1) + 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx) + 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn) + 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2) + 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx) + 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx) + 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) + 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds) +1. [Server Management](#server-management) + 1. [Requirements](#requirements) + 1. [Addressing](#addressing) + 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses) + 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses) +1. [Server Specifications](#server-specifications) + 1. [Server Types](#server-types) + 1. [Naming Convention](#naming-convention) +1. [Testbeds Configuration](#testbeds-configuration) + 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming) + 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod) + 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod) + 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod) + 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod) + 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo) + 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify) + 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod) + 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod]) + 1. [2-Node-ThunderX2 Servers (2n-tx2) WIP](#2-node-thunderx2-servers-2n-tx2-wip) + 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod) + 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod) + 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify) + 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod) + 1. [Per Testbed Wiring](#per-testbed-wiring) + 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod) + 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod) + 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod) + 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod) + 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo) + 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify) + 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod) + 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod]) + 1. [2-Node-ThunderX2 Wiring (2n-tx2) WIP](#2-node-thunderx2-wiring-2n-tx2-wip) + 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod) + 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod) + 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo) + 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod) +1. [Inventory](#inventory) + 1. [Appliances](#appliances) + 1. [Arm Servers](#arm-servers) + 1. [Xeon and Atom Servers](#xeon-and-atom-servers) + 1. [Network Interface Cards](#network-interface-cards) + 1. [Pluggables and Cables](#pluggables-and-cables) + 1. [Other Parts](#other-parts) + +## Purpose This note includes specification of the physical testbed infrastructure hosted by LFN FD.io CSIT project. @@ -62,75 +71,111 @@ hosted by LFN FD.io CSIT project. ### Summary List ``` - #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb - 1. 1-Node-Skylake func skx na 2 2 0 0 2 0 0 0 0 0 0 - 2. 1-Node-Thunderx2 func tx2 na 1 1 0 0 0 0 0 0 1 0 0 - 3. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 - 4. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 - 5. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 - 6. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 - 7. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 - 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 - 9. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0 -10. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2 -11. 1-Node-VIRL func hsw --- 3 3 0 3 0 0 0 0 0 0 0 - Totals: 17 26 14 12 19 1 2 1 1 2 2 + #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2 + 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 0 + 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 + 3. 1-Node-ThunderX2 perf tx2 na 1 1 .5 0 .5 0 0 0 1 0 0 0 + 4. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 + 5. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0 + 6. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 + 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 + 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 + 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0 +10. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 0 +11. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 +12. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 +13. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 +14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 +15. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2 + Totals: 27 36 18 12 19 1 2 3 3 2 7 2 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) -Each 1-Node-Skylake testbed includes one SUT (Type-B6 server) with NIC -ports connected back-to-back. +Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC +ports connected back-to-back ([Server Types](#server-types)). Used for FD.io VPP_Device functional driver tests. ### 1-Node-ThunderX2 Arm Marvell (1n-tx2) -Each 1-Node-ThunderX2 testbed includes one SUT (Type-B9 server) with NIC -ports connected back-to-back. +Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC +ports connected back-to-back ([Server Types](#server-types)). +Used for FD.io VPP_Device functional driver tests. + +### 1-Node-Cascadelake Xeon Intel (1n-clx) + +Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with +NIC ports connected back-to-back ([Server Types](#server-types)). + Used for FD.io VPP_Device functional driver tests. ### 2-Node-Skylake Xeon Intel (2n-skx) -Each 2-Node-Skylake testbed includes one SUT (Type-B1 server) and one TG -(Type-B2 server) connected back-to-back. +Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG +(Server-Type-B2) connected in a 2-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. ### 2-Node-Denverton Atom Intel (2n-dnv) -Each 2-Node-Skylake testbed includes one SUT (Type-B10 server) and one TG -(Type-B2 server) connected back-to-back. +Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one +TG (Server-Type-B2) connected in a 2-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1) -Each 2-Node-IxiaPS1L47 testbed includes one SUT (Type-B1 server) and one -TG (Ixia PSOne appliance) with 10GE interfaces connected back-to-back. +Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one +TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node +circular topology ([Server Types](#server-types)). Used for FD.io TCP/IP and HTTP performance tests. -### 3-Node-Haswell Xeon Intel (3n-skx) +### 2-Node-Cascadelake Xeon Intel (2n-clx) -### 3-Node-Skylake Xeon Intel (3n-skx) +Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and +one TG (Server-Type-C3) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 2-Node-Zen2 EPYC AMD (2n-zn2) -Each 3-Node-Skylake testbed includes two SUTs (Type-B1 servers) and one -TG (Type-B2 server) connected in full-mesh triangle. +Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and +one TG (Server-Type-D2) connected in a 2-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. -### 3-Node-TaiShan Arm Huawei (3n-tsh) +### 2-Node-ThunderX2 Arm Marvell (2x-tx2) + +Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) and +one TG (Server-Type-B12) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 3-Node-Haswell Xeon Intel (3n-hsw) + +Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one +TG (Server-Type-A2) connected in a 3-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 3-Node-Skylake Xeon Intel (3n-skx) -Each 3-Node-TaiShan testbed includes two SUTs (Type-B3 server) and one TG -(Type-B2 server) connected in full-mesh triangle. +Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one +TG (Server-Type-B2) connected in a 3-node circular topology. Used for FD.io performance tests. -### 3-Node-MACCHIATObin Arm Marvell +### 3-Node-TaiShan Arm Huawei (3n-tsh) -Each 3-Node-MACCHIATObin testbed includes two SUTs (Type-B4 server) and -one TG (Type-B2 server) connected in full-mesh triangle. +Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one +TG (Server-Type-B12) connected in a 3-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. ### 3-Node-Rangeley Atom Testbeds -Each 3-Node-Rangeley testbed includes two SUTs (Type-B5 Netgate device) -and one TG (Type-2 server) connected in full-mesh triangle. +Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one +TG (Server-Type-2) connected in a 3-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. ## Server Management @@ -143,16 +188,16 @@ connected to the management network: ``` - 1GE IPMI port - IPMI - Intelligent Platform Management Interface. - - Required for access to embedded server management with WebUI, CLI, SNMPv3, - IPMIv2.0, for firmware (BIOS) and OS updates. + - Required for access to embedded server management with WebUI, CLI, + SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates. - 1GE/10GE/40GE management port - hostOS management port for general system management. ``` ### Addressing -Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management -port, which are connected to two different VLANs. +Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a +Management port, which are connected to two different VLANs. ``` 1. LOM (IPMI) VLAN: @@ -200,11 +245,21 @@ Name | Comment 10.30.50.24 | t3-tg1 10.30.50.25 | t3-sut1 10.30.50.26 | t3-sut-2 -10.30.50.28 | t4-sut1 -10.30.50.29 | t4-sut2 -10.30.50.30 | t4-sut3 +10.30.50.28 | s41-nomad +10.30.50.29 | s39-nomad +10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0 +10.30.50.30 | s40-nomad +10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1 +10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2 +10.30.50.32 | s42-nomad +10.30.50.33 | s43-nomad +10.30.50.34 | s44-nomad +10.30.50.35 | s45-nomad 10.30.50.36 | s17-t33-sut1 10.30.50.37 | s18-t33-sut2 +10.30.50.38 | fdio-marvell-dev +10.30.50.39 | s53-nomad +10.30.50.40 | s54-nomad 10.30.50.41 | s3-t21-sut1 10.30.50.42 | s4-t21-tg1 10.30.50.43 | s11-t31-sut1 @@ -224,8 +279,35 @@ Name | Comment 10.30.50.57 | s16-t32-tg1 10.30.50.58 | s25-t25-sut1 10.30.50.59 | s26-t25-tg1 -10.30.50.69 | s27-t13-sut +10.30.50.65 | s52-nomad +10.30.50.66 | s51-nomad +10.30.50.67 | s49-nomad +10.30.50.68 | s50-nomad +10.30.50.69 | s27-t34-sut1 +10.30.50.70 | s55-t36-sut1 +10.30.50.71 | s56-t37-sut1 10.30.50.255 | Broadcast +n/a | s20-t34-sut1 +n/a | s21-t34-sut2 +10.30.55.0 | network +10.30.55.1 | Router +10.30.55.10 | s28-t26t35-tg1 +10.30.55.11 | s29-t26-sut1 +10.30.55.12 | s30-t35-sut1 +10.30.55.13 | s31-t35-sut2 +10.30.55.14 | s46-nomad +10.30.55.15 | s47-nomad +10.30.55.16 | s48-nomad +10.30.55.17 | s57-nomad +10.30.55.18 | s33-t27-sut1 +10.30.55.19 | s34-t27-tg1 +10.30.55.20 | s35-t28-sut1 +10.30.55.21 | s36-t28-tg1 +10.30.55.22 | s37-t29-sut1 +10.30.55.23 | s38-t29-tg1 +10.30.55.24 | s60-t210-sut1 +10.30.55.25 | s61-t210-tg1 +10.30.55.255 | Broadcast ### Management VLAN IP Addresses @@ -243,9 +325,9 @@ Name | Comment 10.30.51.9 | s22-t35-sut1 (netgate-1) 10.30.51.10 | s23-t35-sut2 (netgate-2) 10.30.51.11 | s24-t35-sut3 (netgate-3) -10.30.51.12 | softiron-1 -10.30.51.13 | softiron-2 -10.30.51.14 | softiron-3 +10.30.51.12 | softiron-1 (decommissioned) +10.30.51.13 | softiron-2 (decommissioned) +10.30.51.14 | softiron-3 (decommissioned) 10.30.51.15 | LF Reserved 10.30.51.16 | t1-tg1 10.30.51.17 | t1-sut1 @@ -256,16 +338,21 @@ Name | Comment 10.30.51.24 | t3-tg1 10.30.51.25 | t3-sut1 10.30.51.26 | t3-sut-2 -10.30.51.28 | t4-sut1 -10.30.51.29 | t4-sut2 -10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0, TO BE VERIFIED -10.30.51.30 | t4-sut3 -10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1, TO BE VERIFIED -10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2, TO BE VERIFIED +10.30.51.28 | s41-nomad +10.30.51.29 | s39-nomad +10.30.51.30 | s40-nomad +10.30.51.32 | s42-nomad +10.30.51.33 | s43-nomad +10.30.51.34 | s44-nomad +10.30.51.35 | s45-nomad 10.30.51.36 | s17-t33-sut1 10.30.51.37 | s18-t33-sut2 -10.30.51.41 | s20-t34-sut1 -10.30.51.42 | s21-t34-sut2 +10.30.51.38 | fdio-marvell-dev +10.30.51.39 | s53-nomad +10.30.51.40 | s54-nomad +10.30.51.41 | s20-t34-sut1 (decommissioned) +10.30.51.42 | s21-t34-sut2 (decommissioned) +10.30.51.43 | fdio-mcbin3 (decommissioned) 10.30.51.44 | s3-t21-sut1 10.30.51.45 | s4-t21-tg1 10.30.51.46 | s11-t31-sut1 @@ -285,17 +372,44 @@ Name | Comment 10.30.51.60 | s16-t32-tg1 10.30.51.61 | s25-t25-sut1 10.30.51.62 | s26-t25-tg1 -10.30.51.69 | s27-t13-sut1 -10.30.51.70-10.30.51.105 | VIRL1 TO BE VERIFIED -10.30.51.106-10.30.51.180 | VIRL2 -10.30.51.181-10.30.51.254 | VIRL3 +10.30.51.65 | s52-nomad +10.30.51.66 | s51-nomad +10.30.51.67 | s49-nomad +10.30.51.68 | s50-nomad +10.30.51.69 | s27-t34-sut1 +10.30.51.70 | s55-t36-sut1 +10.30.51.71 | s56-t37-sut1 +10.30.51.72-10.30.51.105 | FREE +10.30.51.106-10.30.51.180 | FREE +10.30.51.181-10.30.51.254 | FREE 10.30.51.255 | Broadcast - -## Server Type Specification +10.32.8.0 | network +10.32.8.1 | Router +10.32.8.10 | s28-t26t35-tg1 +10.32.8.11 | s29-t26-sut1 +10.32.8.12 | s30-t35-sut1 +10.32.8.13 | s31-t35-sut2 +10.32.8.14 | s46-nomad +10.32.8.15 | s47-nomad +10.32.8.16 | s48-nomad +10.32.8.17 | s57-nomad +10.32.8.18 | s33-t27-sut1 +10.32.8.19 | s34-t27-tg1 +10.32.8.20 | s35-t28-sut1 +10.32.8.21 | s36-t28-tg1 +10.32.8.22 | s37-t29-sut1 +10.32.8.23 | s38-t29-tg1 +10.32.8.24 | s60-t210-sut1 +10.32.8.25 | s61-t210-tg1 +10.32.8.255 | Broadcast + +## Server Specifications + +### Server Types FD.io CSIT lab contains following server types: ``` -1. Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing. +1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing. - Quantity: 6 servers. - Physical connectivity: - CIMC and host management ports. @@ -315,7 +429,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot5: Intel NIC x710 2p10GE. - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill) - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes). -2. Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing. +2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing. - Quantity: 3 servers. - Physical connectivity: - CIMC and host management ports. @@ -335,7 +449,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot5: Intel NIC x710 2p10GE. - PCIe Slot6: Intel NIC x710 2p10GE. - MLOM slot: empty. -3. Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing. +3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing. - Quantity: 3 servers. - Physical connectivity: - CIMC and host management ports. @@ -351,7 +465,7 @@ FD.io CSIT lab contains following server types: - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes) - no cards. - MLOM slot: empty. -4. Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing. +4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing. - Quantity: --- - Physical connectivity: - IPMI and host management ports. @@ -359,19 +473,19 @@ FD.io CSIT lab contains following server types: - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox. + - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -2. Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing. +5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing. - Quantity: --- - Physical connectivity: - IPMI and host management ports. @@ -379,44 +493,32 @@ FD.io CSIT lab contains following server types: - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox. + - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. -3. Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. +6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: - IPMI(?) and host management ports. - NIC ports connected into 3-node topology. - Main HW configuration: - Chassis: Huawei TaiShan 2280. - - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72 + - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72 - RAM Memory: 8* 16GB DDR4-2400MT/s - Disks: 1* 4TB SATA HDD - NICs configuration: - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. - - PCIe Slot6 11:00.xx: 82599-2p10GE Intel. -4. Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing. - - Quantity: 3 - - Physical connectivity: - - Host management ports. - - NIC ports connected into 2-node and 3-node topologies. - - Main HW configuration: - - Chassis: MACCHIATObin. - - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72 - - RAM Memory: 1* 16GB DDR4 - - Disks: 1* 128GB(?) SATA SDD - - NICs configuration: - - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP) -5. Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing. + - PCIe Slot6 11:00.xx: x520-2p10GE Intel. +7. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing. - Quantity: TBD based on testbed allocation. - Physical connectivity: - Management: serial Port (usb) for console @@ -429,15 +531,15 @@ FD.io CSIT lab contains following server types: - NICs configuration: - 2x 10Gb Intel 82599ES - 4x 1GB Intel I354 -6. Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. +8. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. - - NIC ports connected into 2-node and 3-node topologies. + - NIC ports connected into 1-node topologies. - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: @@ -449,7 +551,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -7. Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. +9. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. - Quantity: 1. - Physical connectivity: - Host management interface: 10/100/1000-BaseT. @@ -468,7 +570,7 @@ FD.io CSIT lab contains following server types: - Port-2: 10GE SFP+. - Port-3: 10GE SFP+. - Port-4: 10GE SFP+. -8. Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. +10. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -476,7 +578,7 @@ FD.io CSIT lab contains following server types: - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: @@ -488,24 +590,23 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -9. Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. +11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. - Quantity: 1 - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 1-node topologies. - Main HW configuration: - Chassis: Gigabyte R181-T90 1U - - Motheboard: MT91-FS1 - - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz + - Motherboard: MT91-FS1 + - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz - RAM Memory: 4* 32GB RDIMM - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - NICs configuration: - Numa0: - - PCIe Slot1 05:00.xx: XL710-QDA2. - - PCIe Slot3 08:00.xx: XL710-QDA2. + - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel. - Numa1: - - PCIe Slot6 85:00.xx: XL710-QDA2. -10. Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing. + - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. +12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing. - Quantity: 4 - Physical connectivity: - IPMI and host management ports. @@ -519,9 +620,155 @@ FD.io CSIT lab contains following server types: - 2x 10Gb Intel x553 fiber ports - 2x 10Gb Intel x553 copper ports - 4x 1GB Intel I350 ports +13. Server-Type-B11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. + - Quantity: 2 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 1-node topologies. + - Main HW configuration: + - Chassis: GIGABYTE Rack Mount + - Motherboard: MT91-FS4-00 + - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz + - RAM Memory: 16 * 16GB DIMM + - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480 + - NICs configuration: + - Numa0: + - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox. + - Numa1: + - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox. +14. Server-Type-B12: Purpose - Skylake Xeon TG for FD.io performance testing. + - Quantity: --- + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and 3-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.5 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. + +15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 1-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8280 2.7 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 2* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing. + - Quantity: 3 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Gold 6252N 2.3 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 2* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8280 2.7 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 2* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. + - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. + - Quantity: 3. + - Physical connectivity: + - CIMC and host management ports. + - no NIC ports, standalone setup. + - Main HW configuration: + - Chassis: SuperMicro 1029P-WTRT. + - Motherboard: SuperMicro X11DDW-NT. + - Processors: 2* Intel Platinum 8280 2.7 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 4* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: + - no cards. + - Numa1: + - no cards. + +19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro AS-1114S-WTRT + - Processors: 1* AMD EPYC 7532 2.4 GHz. + - RAM Memory: 8* 32GB DDR4-2933. + - Disks: 1* 1TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot1 01:00.xx: x710-4p10GE Intel. + - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. +20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro AS-1114S-WTRT + - Processors: 1* AMD EPYC 7532 2.4 GHz. + - RAM Memory: 8* 32GB DDR4-2933. + - Disks: 1* 1TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. + - PCIe Slot2 41:00.xx: x710-4p10GE Intel. + - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel. ``` -### Server and Port Naming +### Naming Convention Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds: @@ -546,10 +793,10 @@ connectivity and wiring across defined CSIT testbeds: ### Per Testbed Server Allocation and Naming -#### 1-Node-Skylake (1n-skx) PROD +#### 1-Node-Skylake Servers (1n-skx) PROD ``` -- ServerB1 [Type-B6]: +- SUT [Server-Type-B6]: - testbedname: testbed11. - hostname: s1-t11-sut1. - IPMI IP: 10.30.50.47 @@ -563,7 +810,7 @@ connectivity and wiring across defined CSIT testbeds: - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE. -- ServerB2 [Type-B6]: +- SUT [Server-Type-B6]: - testbedname: testbed12. - hostname: s2-t12-sut1. - IPMI IP: 10.30.50.48 @@ -579,27 +826,62 @@ connectivity and wiring across defined CSIT testbeds: - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE. ``` -#### 1-Node-Thunderx2 (1n-tx2) WIP +#### 1-Node-ThunderX2 Servers (1n-tx2) PROD ``` -- ServerB17 [Type-B9]: - - testbedname: testbed13. - - hostname: s27-t13-sut1. - - IPMI IP: 10.30.50.69 - - Host IP: 10.30.51.69 +- SUT [Server-Type-B11]: + - testbedname: testbed36 + - hostname: s55-t36-sut1 + - IPMI IP: 10.30.50.70 + - Host IP: 10.30.51.70 + - portnames: + - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. + - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. +- SUT [Server-Type-B11]: + - testbedname: testbed37 + - hostname: s56-t37-sut1 + - IPMI IP: 10.30.50.71 + - Host IP: 10.30.51.71 - portnames: - - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. + - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. ``` -#### 2-Node-Skylake (2n-skx) PROD +#### 1-Node-Cascadelake Servers (1n-clx) PROD ``` -- ServerB3 [Type-B1]: +- SUT [Server-Type-C1]: + - testbedname: testbed11. + - hostname: s32-t14-sut1. + - IPMI IP: 10.30.55.17 + - Host IP: 10.32.8.17 + - portnames: + - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE. + - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE. + - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE. + - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE. +``` + +#### 2-Node-Skylake Servers (2n-skx) PROD + +``` +- SUT [Server-Type-B1]: - testbedname: testbed21. - hostname: s3-t21-sut1. - IPMI IP: 10.30.50.41 @@ -611,9 +893,7 @@ connectivity and wiring across defined CSIT testbeds: - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB4 [Type-B2]: +- TG [Server-Type-B2]: - testbedname: testbed21. - hostname: s4-t21-tg1. - IPMI IP: 10.30.50.42 @@ -625,9 +905,7 @@ connectivity and wiring across defined CSIT testbeds: - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB5 [Type-B1]: +- SUT [Server-Type-B1]: - testbedname: testbed22. - hostname: s5-t22-sut1. - IPMI IP: 10.30.50.49 @@ -639,9 +917,7 @@ connectivity and wiring across defined CSIT testbeds: - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB6 [Type-B2]: +- TG [Server-Type-B2]: - testbedname: testbed22. - hostname: s6-t22-tg1. - IPMI IP: 10.30.50.50 @@ -653,9 +929,7 @@ connectivity and wiring across defined CSIT testbeds: - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB7 [Type-B1]: +- SUT [Server-Type-B1]: - testbedname: testbed23. - hostname: s7-t23-sut1. - IPMI IP: 10.30.50.51 @@ -667,9 +941,7 @@ connectivity and wiring across defined CSIT testbeds: - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB8 [Type-B2]: +- TG [Server-Type-B2]: - testbedname: testbed23. - hostname: s8-t23-tg1. - IPMI IP: 10.30.50.52 @@ -681,9 +953,7 @@ connectivity and wiring across defined CSIT testbeds: - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB9 [Type-B1]: +- SUT [Server-Type-B1]: - testbedname: testbed24. - hostname: s9-t24-sut1. - IPMI IP: 10.30.50.53 @@ -695,9 +965,7 @@ connectivity and wiring across defined CSIT testbeds: - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB10 [Type-B2]: +- TG [Server-Type-B2]: - testbedname: testbed24. - hostname: s10-t24-tg1. - IPMI IP: 10.30.50.54 @@ -709,20 +977,47 @@ connectivity and wiring across defined CSIT testbeds: - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. ``` -#### 2-Node-Denverton (2n-dnv) TODO +#### 2-Node-Denverton Servers (2n-dnv) WIP + +Note: ServerB28 (TG) is shared between testbed26 & testbed35 ``` -To be completed. +- TG [Server-Type-B2]: + - testbednames: testbed26 and testbed35. + - hostname: s28-t26t35-tg1. + - IPMI IP: 10.30.55.10 + - Host IP: 10.32.8.10 + - portnames: + - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE. + - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE. + - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE. + - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE. + - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE. + - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE. + - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE. + - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE. + - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE. + - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE. + - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE. + - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE. +- SUT [Server-Type-B10]: + - testbednames: testbed26. + - hostname: s29-t26-sut1. + - IPMI IP: 10.30.55.11 + - Host IP: 10.32.8.11 + - portnames: + - s29-t26-sut1-p1 - 10GE-port1 x553 copper port. + - s29-t26-sut1-p2 - 10GE-port2 x553 copper port. + - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port. + - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port. ``` -#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY +#### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY ``` -- ServerB25 [Type-B8]: +- SUT [Server-Type-B8]: - testbedname: testbed25. - hostname: s25-t25-sut1. - IPMI IP: 10.30.50.58 @@ -732,7 +1027,7 @@ To be completed. - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE. -- ServerB26 [Type-B7]: +- TG [Server-Type-B7]: - testbedname: testbed25. - hostname: s26-t25-tg1. - IPMI IP: 10.30.50.59 @@ -744,10 +1039,179 @@ To be completed. - s26-t25-tg1-p4 - 10GE-port4. ``` -#### 3-Node-Haswell (3n-hsw) PROD +#### 2-Node-Cascadelake Servers (2n-clx) PROD + +``` +- SUT [Server-Type-C2]: + - testbedname: testbed27. + - hostname: s33-t27-sut1. + - IPMI IP: 10.30.55.18 + - Host IP: 10.32.8.18 + - portnames: + - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE. + - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-C3]: + - testbedname: testbed27. + - hostname: s34-t27-tg1. + - IPMI IP: 10.30.55.19 + - Host IP: 10.32.8.19 + - portnames: + - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE. + - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE. + - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- SUT [Server-Type-C2]: + - testbedname: testbed28. + - hostname: s35-t28-sut1. + - IPMI IP: 10.30.55.20 + - Host IP: 10.32.8.20 + - portnames: + - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE. + - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-C3]: + - testbedname: testbed28. + - hostname: s36-t28-tg1. + - IPMI IP: 10.30.55.21 + - Host IP: 10.32.8.21 + - portnames: + - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE. + - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE. + - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- SUT [Server-Type-C2]: + - testbedname: testbed29. + - hostname: s37-t29-sut1. + - IPMI IP: 10.30.55.22 + - Host IP: 10.32.8.22 + - portnames: + - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE. + - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-C3]: + - testbedname: testbed29. + - hostname: s38-t29-tg1. + - IPMI IP: 10.30.55.23 + - Host IP: 10.32.8.23 + - portnames: + - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE. + - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE. + - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +``` + +#### 2-Node-Zen2 Servers (2n-zn2) PROD + +``` +- SUT [Server-Type-D1]: + - testbedname: testbed210. + - hostname: s60-t210-sut1. + - IPMI IP: 10.30.55.24 + - Host IP: 10.32.8.24 + - portnames: + - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE. + - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE. + - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE. + - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE. + - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE. + - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-D2]: + - testbedname: testbed210. + - hostname: s61-t210-tg1. + - IPMI IP: 10.30.55.25 + - Host IP: 10.32.8.25 + - portnames: + - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE. + - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE. + - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE. +``` + +#### 2-Node-ThunderX2 Servers (2x-tx2) WIP + +Note: Server19 (TG) is shared between testbed33 & testbed34 + +``` +- SUT [Server-Type-B9]: + - testbedname: testbed34. + - hostname: s27-t34-sut1. + - IPMI IP: 10.30.50.69 + - Host IP: 10.30.51.69 + - portnames: + - s27-t34-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t34-sut1-c6/p2 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t34-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t34-sut1-c18/p2 - 40GE-port1 XL710-QDA2-2p40GE. +- TG [Server-Type-B12]: + - testbedname: testbed33 and testbed34. + - hostname: s19-t33t34-tg1. + - IPMI IP: 10.30.50.46 + - Host IP: 10.30.51.49 + - portnames: + - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE. + - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE. +``` + +#### 3-Node-Haswell Servers (3n-hsw) PROD ``` - 1. Server1 of Type-1: + 1. SUT [Server-Type-A1]: - testbedname: testbed1. - hostname: t1-sut1. - CIMC IP: 10.30.50.17 @@ -763,7 +1227,7 @@ To be completed. - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 2. Server2 of Type-1: + 2. SUT [Server-Type-A1]: - testbedname: testbed1. - hostname: t1-sut2. - CIMC IP: 10.30.50.18 @@ -779,7 +1243,7 @@ To be completed. - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 3. Server3 of Type-2: + 3. TG [Server-Type-A2]: - testbedname: testbed1. - hostname: t1-tg1. - CIMC IP: 10.30.50.16 @@ -797,7 +1261,7 @@ To be completed. - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. - 4. Server4 of Type-1: + 4. SUT [Server-Type-A1]: - testbedname: testbed2. - hostname: t2-sut1. - CIMC IP: 10.30.50.21 @@ -813,7 +1277,7 @@ To be completed. - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 5. Server5 of Type-1: + 5. SUT [Server-Type-A1]: - testbedname: testbed2. - hostname: t2-sut2. - CIMC IP: 10.30.50.22 @@ -829,7 +1293,7 @@ To be completed. - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 6. Server6 of Type-2: + 6. TG [Server-Type-A2]: - testbedname: testbed2. - hostname: t2-tg1. - CIMC IP: 10.30.50.20 @@ -847,7 +1311,7 @@ To be completed. - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. - 7. Server7 of Type-1: + 7. SUT [Server-Type-A1]: - testbedname: testbed3. - hostname: t3-sut1. - CIMC IP: 10.30.50.25 @@ -863,7 +1327,7 @@ To be completed. - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 8. Server8 of Type-1: + 8. SUT [Server-Type-A1]: - testbedname: testbed3. - hostname: t3-sut2. - CIMC IP: 10.30.50.26 @@ -879,7 +1343,7 @@ To be completed. - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 9. Server9 of Type-2: + 9. TG [Server-Type-A2]: - testbedname: testbed3. - hostname: t3-tg1. - CIMC IP: 10.30.50.24 @@ -899,10 +1363,10 @@ To be completed. - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. ``` -#### 3-Node-Skylake (3n-skx) PROD +#### 3-Node-Skylake Servers (3n-skx) PROD ``` -- ServerB11 [Type-B1]: +- ServerB11 [Server-Type-B1]: - testbedname: testbed31. - hostname: s11-t31-sut1. - IPMI IP: 10.30.50.43 @@ -916,7 +1380,7 @@ To be completed. - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB12 [Type-B1]: +- ServerB12 [Server-Type-B1]: - testbedname: testbed31. - hostname: s12-t31-sut2. - IPMI IP: 10.30.50.44 @@ -930,7 +1394,7 @@ To be completed. - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB13 [Type-B2]: +- ServerB13 [Server-Type-B2]: - testbedname: testbed31. - hostname: s13-t31-tg1. - IPMI IP: 10.30.50.45 @@ -944,7 +1408,7 @@ To be completed. - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB14 [Type-B1]: +- ServerB14 [Server-Type-B1]: - testbedname: testbed32. - hostname: s14-t32-sut1. - IPMI IP: 10.30.50.55 @@ -958,7 +1422,7 @@ To be completed. - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB15 [Type-B1]: +- ServerB15 [Server-Type-B1]: - testbedname: testbed32. - hostname: s15-t32-sut2. - IPMI IP: 10.30.50.56 @@ -972,7 +1436,7 @@ To be completed. - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB16 [Type-B2]: +- ServerB16 [Server-Type-B2]: - testbedname: testbed32. - hostname: s16-t32-tg1. - IPMI IP: 10.30.50.57 @@ -988,14 +1452,12 @@ To be completed. - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. ``` -Note: ServerB19 (TG) is shared between testbed33 & testbed34 - -#### 3-Node-Rangeley (3n-rng) VERIFY +#### 3-Node-Rangeley Servers (3n-rng) VERIFY Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. ``` -- ServerB22 [Type-B5]: +- ServerB22 [Server-Type-B5]: - testbedname: testbed35. - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1). - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0 @@ -1004,7 +1466,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s22-t35-sut1-p1 - 10GE-port1 ix0 82599. - s22-t35-sut1-p2 - 10GE-port2 ix1 82599. - 1GB ports (tbd) -- ServerB23 [Type-B5]: +- ServerB23 [Server-Type-B5]: - testbedname: testbed35. - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2). - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1 @@ -1013,7 +1475,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s23-t35-sut1-p1 - 10GE-port1 ix0 82599. - s23-t35-sut1-p2 - 10GE-port2 ix1 82599. - 1GB ports (tbd) -- ServerB24 [Type-B5]: +- ServerB24 [Server-Type-B5]: - testbedname: testbed35. - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3). - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2 @@ -1024,31 +1486,33 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - 1GB ports (tbd) ``` -#### 3-Node-Taishan (3n-tsh) WIP +#### 3-Node-Taishan Servers (3n-tsh) PROD + +Note: Server19 (TG) is shared between testbed33 & testbed34 ``` -- ServerB17 [Type-B3]: +- SUT [Server-Type-B3]: - testbedname: testbed33. - hostname: s17-t33-sut1. - IPMI IP: 10.30.50.36 - Host IP: 10.30.51.36 - portnames: - - s17-t33-sut1-c6/p1 - 10GE-port1 82599-2p10GE. - - s17-t33-sut1-c6/p2 - 10GE-port2 82599-2p10GE. + - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE. + - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE. - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE. - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE. -- ServerB18 [Type-B3]: +- SUT [Server-Type-B3]: - testbedname: testbed33. - hostname: s18-t33-sut2. - IPMI IP: 10.30.50.37 - Host IP: 10.30.51.37 - portnames: - - s18-t33-sut2-c6/p1 - 10GE-port1 82599-2p10GE. - - s18-t33-sut2-c6/p2 - 10GE-port2 82599-2p10GE. + - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE. + - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE. - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE. - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE. -- ServerB19 [Type-B2]: - - testbednames: testbed33 and testbed34. +- TG [Server-Type-B12]: + - testbedname: testbed33 and testbed34. - hostname: s19-t33t34-tg1. - IPMI IP: 10.30.50.46 - Host IP: 10.30.51.49 @@ -1059,37 +1523,42 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE. - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE. -- ServerB20 [Type-B4]: - - testbedname: testbed34. - - hostname: s20-t34-sut1. - - IPMI IP: N/A - - Host IP: 10.30.51.41 - - portnames: - - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell. - - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell. -- ServerB21 [Type-B4]: - - testbedname: testbed34. - - hostname: s21-t34-sut2. - - IPMI IP: N/A - - Host IP: 10.30.51.42 - - portnames: - - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell. - - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell. ``` -#### 3-Node-Mcbin (3n-mcb) TODO +#### 3-Node-Denverton Servers (3n-dnv) WIP ``` -To be completed. +- ServerB30 [Server-Type-B10]: + - testbednames: testbed35. + - hostname: s30-t35-sut1. + - IPMI IP: 10.30.55.12 + - Host IP: 10.32.8.12 + - portnames: + - s30-t35-sut1-p1 - 10GE-port1 x553 copper port. + - s30-t35-sut1-p2 - 10GE-port2 x553 copper port. + - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port. + - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port. +- ServerB31 [Server-Type-B10]: + - testbednames: testbed35. + - hostname: s31-t35-sut2. + - IPMI IP: 10.30.55.13 + - Host IP: 10.32.8.13 + - portnames: + - s31-t35-sut2-p1 - 10GE-port1 x553 copper port. + - s31-t35-sut2-p2 - 10GE-port2 x553 copper port. + - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port. + - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port. ``` ### Per Testbed Wiring -#### 1-Node-Skylake (1n-skx) PROD +#### 1-Node-Skylake Wiring (1n-skx) PROD ``` - testbed11: @@ -1112,19 +1581,45 @@ To be completed. - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. ``` -#### 1-Node-Thunderx2 (1n-tx2) WIP +#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD ``` -- testbed13: +- testbed36: - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1. + - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1. - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1. - - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1. + - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2. + - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1. + - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2. + +- testbed37: + - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: + - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1. + - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: + - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2. + - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1. + - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2. +``` + +#### 1-Node-Cascadelake Wiring (1n-clx) PROD + +``` +- testbed14: + - ring1 10GE-ports x710-4p10GE: + - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1. + - ring2 10GE-ports x710-4p10GE: + - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2. + - ring3 10GE-ports x710-4p10GE: + - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3. + - ring4 10GE-ports x710-4p10GE: + - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3. ``` -#### 2-Node-Skylake (2n-skx) PROD +#### 2-Node-Skylake Wiring (2n-skx) PROD ``` - testbed21: @@ -1137,12 +1632,6 @@ To be completed. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1. - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1. - - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2. - - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2. - - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4. - testbed22: - ring1 10GE-ports x710-4p10GE on SUT: - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1. @@ -1153,12 +1642,6 @@ To be completed. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1. - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1. - - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2. - - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2. - - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4. - testbed23: - ring1 10GE-ports x710-4p10GE on SUT: - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1. @@ -1169,12 +1652,6 @@ To be completed. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1. - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1. - - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2. - - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2. - - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4. - testbed24: - ring1 10GE-ports x710-4p10GE on SUT: - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1. @@ -1185,21 +1662,21 @@ To be completed. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1. - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1. - - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2. - - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2. - - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4. ``` -#### 2-Node-Denverton (2n-dnv) TODO +#### 2-Node-Denverton Wiring (2n-dnv) WIP ``` -To be completed. +- testbed26: + - ring1 10GE-ports x553 copper port on SUT: + - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1. + - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2. + - ring2 10GE-ports x553 fiber port on SUT: + - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3. + - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4. ``` -#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY +#### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY ``` - testbed25: @@ -1213,7 +1690,88 @@ To be completed. - t25-tg1-p4 to t25-sut1-c2/p4. ``` -#### 3-Node-Haswell (3n-hsw) PROD +#### 2-Node-Cascadelake Wiring (2n-clx) PROD + +``` +- testbed27: + - ring1 10GE-ports x710-4p10GE on SUT: + - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1. + - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3. + - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1. + - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1. + - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2. + - ring5 100GE-ports e810-2p100GE on SUT: + - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1. + - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2. +- testbed28: + - ring1 10GE-ports x710-4p10GE on SUT: + - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1. + - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3. + - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1. + - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1. + - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2. + - ring5 100GE-ports e810-2p100GE on SUT: + - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1. + - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2. +- testbed29: + - ring1 10GE-ports x710-4p10GE on SUT: + - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1. + - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3. + - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1. + - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1. + - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2. + - ring6 100GE-ports e810-2p100GE on SUT: + - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1. + - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2. +``` + +#### 2-Node-Zen2 Wiring (2n-zn2) PROD + +``` +- testbed210: + - ring1 10GE-ports x710-4p10GE on SUT: + - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1. + - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3. + - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1. + - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1. + - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2. +``` + +#### 2-Node-ThunderX2 Wiring (2n-tx2) WIP + +``` +- testbed34: + - ring1 10GE-ports x520-2p10GE on SUTs: + - s27-t34-sut1-c18/p1 - s19-t33t34-tg1-c8/p1. + - s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2. +``` + + +#### 3-Node-Haswell Wiring (3n-hsw) PROD ``` 1. testbed1: @@ -1289,7 +1847,7 @@ To be completed. - t3-tg1-c6/p1 to t3-tg1-c6/p2. ``` -#### 3-Node-Skylake (3n-skx) PROD +#### 3-Node-Skylake Wiring (3n-skx) PROD ``` - testbed31: @@ -1334,34 +1892,38 @@ To be completed. - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4. ``` -#### 3-Node-Rangeley (3n-rng) TODO +#### 3-Node-Rangeley Wiring (3n-rng) TODO ``` To be completed. ``` -#### 3-Node-Taishan (3n-tsh) WIP +#### 3-Node-Taishan Wiring (3n-tsh) PROD ``` - testbed33: - - ring1 10GE-ports 82599-2p10GE on SUTs: - - t33t34-tg1-c2/p2 - t33-sut1-c6/p2. - - t33-sut1-c6/p1 - t33-sut2-c6/p2. - - t33-sut2-c6/p1 - t33t34-tg1-c2/p1. + - ring1 10GE-ports x520-2p10GE on SUTs: + - s19-t33t34-tg1-c2/p2 - s17-t33-sut1-c6/p2. + - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2. + - s18-t33-sut2-c6/p1 - s19-t33t34-tg1-c2/p1. - ring2 25GE-ports cx4-2p25GE on SUTs: - - t33t34-tg1-c4/p2 - t33-sut1-c4/p2. - - t33-sut1-c4/p1 - t33-sut2-c4/p2. - - t33-sut2-c4/p1 - t33t34-tg1-c4/p1. + - s19-t33t34-tg1-c4/p2 - s17-t33-sut1-c4/p2. + - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2. + - s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1. ``` -#### 3-Node-Mcbin (3n-mcb) WIP +#### 3-Node-Denverton Wiring (3n-dnv) WIP ``` -- testbed34: - - ring1 10GE-ports Marvell on SUTs: - - t33t34-tg1-c2/p3 - t34-sut1-ca/p1. - - t34-sut1-ca/p2 - t34-sut2-ca/p1. - - t34-sut2-ca/p2 - t33t34-tg1-c2/p4. +- testbed35: + - ring1 10GE-ports x553 copper port on SUTs: + - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2. + - s30-t35-sut1-p1 to s31-t35-sut2-p1. + - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2. + - ring2 10GE-ports x553 fiber port on SUTs: + - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4. + - s30-t35-sut1-p3 to s31-t35-sut2-p3. + - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4. ``` ## Inventory @@ -1385,21 +1947,21 @@ To be completed. ``` 1. Arm Cortex A-72 servers - - 1 * ThunderX2 - - Chassis: Marvell ThunderX2 - - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2. + - 2 * ThunderX2 (VPP Device) + - Chassis: GIGABYTE Rack Mount + - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2 + - RAM Memory: 16* 16GB DIMM + - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480 + - 1 * ThunderX2 (Performance) + - Chassis: GIGABYTE Rack Mount + - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2. - RAM Memory: 4* 32GB RDIMM - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - 2 * Huawei TaiShan 2280. - Chassis: Huawei TaiShan 2280. - - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72. + - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72. - RAM Memory: 8* 16GB DDR4-2400MT/s. - Disks: 1* 4TB SATA HDD. - - 3 * MACCHIATObin - - Chassis: MACCHIATObin. - - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72. - - RAM Memory: 1* 16GB DDR4. - - Disks: 1* 128GB(?) SATA SDD. ``` ### Xeon and Atom Servers @@ -1409,7 +1971,7 @@ To be completed. - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors. - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. 2. Intel Atom servers with Rangely processors.