X-Git-Url: https://gerrit.fd.io/r/gitweb?p=csit.git;a=blobdiff_plain;f=docs%2Flab%2Ftestbed_specifications.md;h=8143b7bf726ad4a52601ffdb7439bc45a00f51d4;hp=365eaddb591103a588b7fc168778ed8a7b7f60eb;hb=75351e349449d6c397cb830828dc4f55883511a3;hpb=f754eac4faf76fdbffac648769c03f5668f9f6a2 diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index 365eaddb59..8143b7bf72 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -12,9 +12,12 @@ 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx) 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn) 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2) + 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx) 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx) - 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds) + 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) + 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt) + 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx) 1. [Server Management](#server-management) 1. [Requirements](#requirements) 1. [Addressing](#addressing) @@ -34,9 +37,12 @@ 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod) 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod]) 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod) + 1. [2-Node-Icelake Servers (2n-icx) TBD](#2-node-icelake-servers-2n-icx-tbd) 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod) 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify) 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod) + 1. [3-Node-Altra Servers (3n-alt) TBD](#3-node-altra-servers-3n-alt-tbd) + 1. [3-Node-Icelake Servers (3n-icx) TBD](#3-node-icelake-servers-3n-icx-tbd) 1. [Per Testbed Wiring](#per-testbed-wiring) 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod) 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod) @@ -47,10 +53,12 @@ 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod) 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod]) 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod) - 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod) + 1. [2-Node-Icelake Servers (2n-icx) TBD](#2-node-icelake-servers-2n-icx-tbd) 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod) 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo) 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod) + 1. [3-Node-Altra Wiring (3n-alt) TBD](#3-node-altra-wiring-3n-alt-tbd) + 1. [3-Node-Icelake Wiring (3n-icx) TBD](#3-node-icelake-wiring-3n-icx-tbd) 1. [Inventory](#inventory) 1. [Appliances](#appliances) 1. [Arm Servers](#arm-servers) @@ -69,22 +77,25 @@ hosted by LFN FD.io CSIT project. ### Summary List ``` - #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2 - 1. 1-Node-Haswell nomad hsw --- 4 4 0 4 0 0 0 0 0 0 0 0 - 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 - 3. 1-Node-ThunderX2 perf tx2 na 1 1 .5 0 .5 0 0 0 1 0 0 0 - 4. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 - 5. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 1 0 - 6. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 - 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 - 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 - 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 6 0 -10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 -11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 -12. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 -13. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 -14. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 2 - Totals: 25 31 15 4 19 1 2 3 3 2 7 2 + #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx + 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0 0 0 + 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0 0 + 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 + 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0 0 + 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 0 0 + 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0 0 + 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0 0 + 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0 0 + 9. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 0 1 0 0 0 0 0 +10. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 0 0 8 +11. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 0 +12. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 0 +13. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 0 0 +14. 3-Node-Altra perf alt icx 1 2 .5 0 0 0 0 0 0 0 2 0 0 .5 +15. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 0 +16. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 0 +17. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 6 + Totals: 32 41 21.5 4 19 1 2 3 3 2 2 7 2 14.5 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) @@ -95,7 +106,7 @@ Used for FD.io VPP_Device functional driver tests. ### 1-Node-ThunderX2 Arm Marvell (1n-tx2) -Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC +Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC ports connected back-to-back ([Server Types](#server-types)). Used for FD.io VPP_Device functional driver tests. @@ -143,8 +154,15 @@ Used for FD.io performance tests. ### 2-Node-ThunderX2 Arm Marvell (2x-tx2) -Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) and -one TG (Server-Type-B12) connected in a 2-node circular topology +Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and +one TG (Server-Type-E31) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 2-Node-Icelake Xeon Intel (2n-icx) + +Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and +one TG (Server-Type-F2) connected in a 2-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. @@ -161,17 +179,31 @@ Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one TG (Server-Type-B2) connected in a 3-node circular topology. Used for FD.io performance tests. +### 3-Node-Rangeley Atom Testbeds + +Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one +TG (Server-Type-2) connected in a 3-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + ### 3-Node-TaiShan Arm Huawei (3n-tsh) -Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one -TG (Server-Type-B12) connected in a 3-node circular topology +Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one +TG (Server-Type-E31) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. -### 3-Node-Rangeley Atom Testbeds +### 3-Node-Altra Arm Ampere (3n-alt) -Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one -TG (Server-Type-2) connected in a 3-node circular topology +Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one +TG (Server-Type-F4) connected in a 3-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 3-Node-Icelake Xeon Intel (3n-icx) + +Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one +TG (Server-Type-F3) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. @@ -233,16 +265,16 @@ Name | Comment 10.30.50.13 | LF Reserved 10.30.50.14 | LF Reserved 10.30.50.15 | LF Reserved +10.30.50.22 | s42-nomad +10.30.50.24 | s43-nomad +10.30.50.25 | s44-nomad +10.30.50.26 | s45-nomad 10.30.50.28 | s41-nomad 10.30.50.29 | s39-nomad 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0 10.30.50.30 | s40-nomad 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2 -10.30.50.32 | s42-nomad -10.30.50.33 | s43-nomad -10.30.50.34 | s44-nomad -10.30.50.35 | s45-nomad 10.30.50.36 | s17-t33-sut1 10.30.50.37 | s18-t33-sut2 10.30.50.38 | fdio-marvell-dev @@ -253,7 +285,7 @@ Name | Comment 10.30.50.43 | s11-t31-sut1 10.30.50.44 | s12-t31-sut2 10.30.50.45 | s13-t31-tg1 -10.30.50.46 | s19-t33t34-tg1 +10.30.50.46 | s19-t33t211-tg1 10.30.50.47 | s1-t11-sut1 10.30.50.48 | s2-t12-sut1 10.30.50.49 | s5-t22-sut1 @@ -271,12 +303,29 @@ Name | Comment 10.30.50.66 | s51-nomad 10.30.50.67 | s49-nomad 10.30.50.68 | s50-nomad -10.30.50.69 | s27-t34-sut1 -10.30.50.70 | s55-t36-sut1 -10.30.50.71 | s56-t37-sut1 +10.30.50.69 | s27-t211-sut1 +10.30.50.70 | s55-t13-sut1 +10.30.50.71 | s56-t14-sut1 +10.30.50.72 | s62-t34-sut1 +10.30.50.73 | s63-t34-sut2 +10.30.50.74 | s64-t34t36-tg1 +10.30.50.75 | s65-t37-sut1 +10.30.50.76 | s66-t37-sut2 +10.30.50.77 | s67-t37-tg1 +10.30.50.78 | s68-t38-sut1 +10.30.50.79 | s69-t38-sut2 +10.30.50.80 | s70-t38-tg1 +10.30.50.81 | s71-t212-sut1 +10.30.50.82 | s72-t212-tg1 +10.30.50.83 | s73-t213-sut1 +10.30.50.84 | s74-t213-tg1 +10.30.50.85 | s75-t214-sut1 +10.30.50.86 | s76-t214-tg1 +10.30.50.87 | s77-t215-sut1 +10.30.50.88 | s78-t215-tg1 +10.30.50.89 | s79-t39t310-tg1 +10.30.50.90 | s80-t311t312-tg1 10.30.50.255 | Broadcast -n/a | s20-t34-sut1 -n/a | s21-t34-sut2 10.30.55.0 | network 10.30.55.1 | Router 10.30.55.10 | s28-t26t35-tg1 @@ -299,77 +348,95 @@ n/a | s21-t34-sut2 ### Management VLAN IP Addresses -Name | Comment -------------------------- | ------- -10.30.51.0 | network -10.30.51.1 | Router -10.30.51.2 | LF Reserved -10.30.51.3 | LF Reserved -10.30.51.4 | LF Reserved -10.30.51.5 | LF Reserved -10.30.51.6 | LF Reserved -10.30.51.7 | LF Reserved -10.30.51.8 | LF Reserved -10.30.51.15 | LF Reserved -10.30.51.28 | s41-nomad -10.30.51.29 | s39-nomad -10.30.51.30 | s40-nomad -10.30.51.32 | s42-nomad -10.30.51.33 | s43-nomad -10.30.51.34 | s44-nomad -10.30.51.35 | s45-nomad -10.30.51.36 | s17-t33-sut1 -10.30.51.37 | s18-t33-sut2 -10.30.51.38 | fdio-marvell-dev -10.30.51.39 | s53-nomad -10.30.51.40 | s54-nomad -10.30.51.44 | s3-t21-sut1 -10.30.51.45 | s4-t21-tg1 -10.30.51.46 | s11-t31-sut1 -10.30.51.47 | s12-t31-sut2 -10.30.51.48 | s13-t31-tg1 -10.30.51.49 | s19-t33t34-tg1 -10.30.51.50 | s1-t11-sut1 -10.30.51.51 | s2-t12-sut1 -10.30.51.52 | s5-t22-sut1 -10.30.51.53 | s6-t22-tg1 -10.30.51.54 | s7-t23-sut1 -10.30.51.55 | s8-t23-tg1 -10.30.51.56 | s9-t24-sut1 -10.30.51.57 | s10-t24-tg1 -10.30.51.58 | s14-t32-sut1 -10.30.51.59 | s15-t32-sut2 -10.30.51.60 | s16-t32-tg1 -10.30.51.61 | s25-t25-sut1 -10.30.51.62 | s26-t25-tg1 -10.30.51.65 | s52-nomad -10.30.51.66 | s51-nomad -10.30.51.67 | s49-nomad -10.30.51.68 | s50-nomad -10.30.51.69 | s27-t34-sut1 -10.30.51.70 | s55-t36-sut1 -10.30.51.71 | s56-t37-sut1 -10.30.51.72-10.30.51.254 | FREE -10.30.51.255 | Broadcast -10.32.8.0 | network -10.32.8.1 | Router -10.32.8.10 | s28-t26t35-tg1 -10.32.8.11 | s29-t26-sut1 -10.32.8.12 | s30-t35-sut1 -10.32.8.13 | s31-t35-sut2 -10.32.8.14 | s46-nomad -10.32.8.15 | s47-nomad -10.32.8.16 | s48-nomad -10.32.8.17 | s57-nomad -10.32.8.18 | s33-t27-sut1 -10.32.8.19 | s34-t27-tg1 -10.32.8.20 | s35-t28-sut1 -10.32.8.21 | s36-t28-tg1 -10.32.8.22 | s37-t29-sut1 -10.32.8.23 | s38-t29-tg1 -10.32.8.24 | s60-t210-sut1 -10.32.8.25 | s61-t210-tg1 -10.32.8.255 | Broadcast +Name | Comment +-------------| ------- +10.30.51.0 | network +10.30.51.1 | Router +10.30.51.2 | LF Reserved +10.30.51.3 | LF Reserved +10.30.51.4 | LF Reserved +10.30.51.5 | LF Reserved +10.30.51.6 | LF Reserved +10.30.51.7 | LF Reserved +10.30.51.8 | LF Reserved +10.30.51.15 | LF Reserved +10.30.51.22 | s42-nomad +10.30.51.24 | s43-nomad +10.30.51.25 | s44-nomad +10.30.51.26 | s45-nomad +10.30.51.28 | s41-nomad +10.30.51.29 | s39-nomad +10.30.51.30 | s40-nomad +10.30.51.36 | s17-t33-sut1 +10.30.51.37 | s18-t33-sut2 +10.30.51.38 | fdio-marvell-dev +10.30.51.39 | s53-nomad +10.30.51.40 | s54-nomad +10.30.51.44 | s3-t21-sut1 +10.30.51.45 | s4-t21-tg1 +10.30.51.46 | s11-t31-sut1 +10.30.51.47 | s12-t31-sut2 +10.30.51.48 | s13-t31-tg1 +10.30.51.49 | s19-t33t211-tg1 +10.30.51.50 | s1-t11-sut1 +10.30.51.51 | s2-t12-sut1 +10.30.51.52 | s5-t22-sut1 +10.30.51.53 | s6-t22-tg1 +10.30.51.54 | s7-t23-sut1 +10.30.51.55 | s8-t23-tg1 +10.30.51.56 | s9-t24-sut1 +10.30.51.57 | s10-t24-tg1 +10.30.51.58 | s14-t32-sut1 +10.30.51.59 | s15-t32-sut2 +10.30.51.60 | s16-t32-tg1 +10.30.51.61 | s25-t25-sut1 +10.30.51.62 | s26-t25-tg1 +10.30.51.65 | s52-nomad +10.30.51.66 | s51-nomad +10.30.51.67 | s49-nomad +10.30.51.68 | s50-nomad +10.30.51.69 | s27-t211-sut1 +10.30.51.70 | s55-t13-sut1 +10.30.51.71 | s56-t14-sut1 +10.30.51.72 | s62-t34-sut1 +10.30.51.73 | s63-t34-sut2 +10.30.51.74 | s64-t34t36-tg1 +10.30.51.75 | s65-t37-sut1 +10.30.51.76 | s66-t37-sut2 +10.30.51.77 | s67-t37-tg1 +10.30.51.78 | s68-t38-sut1 +10.30.51.79 | s69-t38-sut2 +10.30.51.80 | s70-t38-tg1 +10.30.51.81 | s71-t212-sut1 +10.30.51.82 | s72-t212-tg1 +10.30.51.83 | s73-t213-sut1 +10.30.51.84 | s74-t213-tg1 +10.30.51.85 | s75-t214-sut1 +10.30.51.86 | s76-t214-tg1 +10.30.51.87 | s77-t215-sut1 +10.30.51.88 | s78-t215-tg1 +10.30.51.89 | s79-t39t310-tg1 +10.30.51.90 | s80-t311t312-tg1 +10.30.51.255 | Broadcast +10.32.8.0 | network +10.32.8.1 | Router +10.32.8.10 | s28-t26t35-tg1 +10.32.8.11 | s29-t26-sut1 +10.32.8.12 | s30-t35-sut1 +10.32.8.13 | s31-t35-sut2 +10.32.8.14 | s46-nomad +10.32.8.15 | s47-nomad +10.32.8.16 | s48-nomad +10.32.8.17 | s57-nomad +10.32.8.18 | s33-t27-sut1 +10.32.8.19 | s34-t27-tg1 +10.32.8.20 | s35-t28-sut1 +10.32.8.21 | s36-t28-tg1 +10.32.8.22 | s37-t29-sut1 +10.32.8.23 | s38-t29-tg1 +10.32.8.24 | s60-t210-sut1 +10.32.8.25 | s61-t210-tg1 +10.32.8.255 | Broadcast ## Server Specifications @@ -473,20 +540,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. -6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. - - Quantity: 2 - - Physical connectivity: - - IPMI(?) and host management ports. - - NIC ports connected into 3-node topology. - - Main HW configuration: - - Chassis: Huawei TaiShan 2280. - - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72 - - RAM Memory: 8* 16GB DDR4-2400MT/s - - Disks: 1* 4TB SATA HDD - - NICs configuration: - - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. - - PCIe Slot6 11:00.xx: x520-2p10GE Intel. -7. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing. +6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing. - Quantity: TBD based on testbed allocation. - Physical connectivity: - Management: serial Port (usb) for console @@ -499,7 +553,7 @@ FD.io CSIT lab contains following server types: - NICs configuration: - 2x 10Gb Intel 82599ES - 4x 1GB Intel I354 -8. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. +7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -519,7 +573,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -9. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. +8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. - Quantity: 1. - Physical connectivity: - Host management interface: 10/100/1000-BaseT. @@ -538,7 +592,7 @@ FD.io CSIT lab contains following server types: - Port-2: 10GE SFP+. - Port-3: 10GE SFP+. - Port-4: 10GE SFP+. -10. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. +9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -558,23 +612,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. - - Quantity: 1 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 1-node topologies. - - Main HW configuration: - - Chassis: Gigabyte R181-T90 1U - - Motherboard: MT91-FS1 - - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz - - RAM Memory: 4* 32GB RDIMM - - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - - NICs configuration: - - Numa0: - - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel. - - Numa1: - - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. -12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing. +10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing. - Quantity: 4 - Physical connectivity: - IPMI and host management ports. @@ -588,46 +626,7 @@ FD.io CSIT lab contains following server types: - 2x 10Gb Intel x553 fiber ports - 2x 10Gb Intel x553 copper ports - 4x 1GB Intel I350 ports -13. Server-Type-B11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. - - Quantity: 2 - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 1-node topologies. - - Main HW configuration: - - Chassis: GIGABYTE Rack Mount - - Motherboard: MT91-FS4-00 - - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz - - RAM Memory: 16 * 16GB DIMM - - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480 - - NICs configuration: - - Numa0: - - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox. - - Numa1: - - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox. -14. Server-Type-B12: Purpose - Skylake Xeon TG for FD.io performance testing. - - Quantity: --- - - Physical connectivity: - - IPMI and host management ports. - - NIC ports connected into 2-node and 3-node topologies. - - Main HW configuration: - - Chassis: SuperMicro SYS-7049GP-TRT. - - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.5 GHz. - - RAM Memory: 16* 16GB DDR4-2666MHz. - - Disks: 2* 1.6TB 6G SATA SSD. - - NICs configuration: - - Numa0: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - - PCIe Slot9 5e:00.xx: empty. - - Numa1: (x16, x16, x16 PCIe3.0 lanes) - - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. - - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. - -15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. +11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -647,7 +646,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing. +12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing. - Quantity: 3 - Physical connectivity: - IPMI and host management ports. @@ -667,7 +666,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing. +13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -687,7 +686,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. +14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. - Quantity: 3. - Physical connectivity: - CIMC and host management ports. @@ -703,7 +702,7 @@ FD.io CSIT lab contains following server types: - no cards. - Numa1: - no cards. -19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing. +15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -718,7 +717,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot1 01:00.xx: x710-4p10GE Intel. - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel. - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. -20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing. +16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -733,6 +732,171 @@ FD.io CSIT lab contains following server types: - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. - PCIe Slot2 41:00.xx: x710-4p10GE Intel. - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel. +17. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. + - Quantity: 2 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 1-node topologies. + - Main HW configuration: + - Chassis: GIGABYTE Rack Mount + - Motherboard: MT91-FS4-00 + - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz + - RAM Memory: 16 * 16GB DIMM + - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480 + - NICs configuration: + - Numa0: + - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox. + - Numa1: + - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox. +18. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. + - Quantity: 2 + - Physical connectivity: + - IPMI(?) and host management ports. + - NIC ports connected into 3-node topology. + - Main HW configuration: + - Chassis: Huawei TaiShan 2280. + - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72 + - RAM Memory: 8* 16GB DDR4-2400MT/s + - Disks: 1* 4TB SATA HDD + - NICs configuration: + - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. + - PCIe Slot6 11:00.xx: x520-2p10GE Intel. +19. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. + - Quantity: 1 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node topologies. + - Main HW configuration: + - Chassis: Gigabyte R181-T90 1U + - Motherboard: MT91-FS1 + - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz + - RAM Memory: 4* 32GB RDIMM + - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 + - NICs configuration: + - Numa0: + - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel. + - Numa1: + - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. +20. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing. + - Quantity: 1 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 3-node topologies. + - Main HW configuration: + - Chassis: TBD + - Motherboard: TBD + - Processors: n* TBD + - RAM Memory: n* TBD + - Disks: TBD + - NICs configuration: + - Numa0: + - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. + - Numa1: + - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. +21. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing. + - Quantity: 1 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and 3-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.5 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. +22. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing. + - Quantity: 8. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node or 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +23. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +24. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +25. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and/or 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: empty. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot10 d8:00.xx: empty. ``` ### Naming Convention @@ -796,34 +960,34 @@ connectivity and wiring across defined CSIT testbeds: #### 1-Node-ThunderX2 Servers (1n-tx2) PROD ``` -- SUT [Server-Type-B11]: - - testbedname: testbed36 - - hostname: s55-t36-sut1 +- SUT [Server-Type-E11]: + - testbedname: testbed13 + - hostname: s55-t13-sut1 - IPMI IP: 10.30.50.70 - Host IP: 10.30.51.70 - portnames: - - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. - - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. -- SUT [Server-Type-B11]: - - testbedname: testbed37 - - hostname: s56-t37-sut1 + - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. + - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. +- SUT [Server-Type-E11]: + - testbedname: testbed14 + - hostname: s56-t14-sut1 - IPMI IP: 10.30.50.71 - Host IP: 10.30.51.71 - portnames: - - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. - - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. - - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. + - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. + - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. ``` #### 1-Node-Cascadelake Servers (1n-clx) PROD @@ -872,6 +1036,10 @@ connectivity and wiring across defined CSIT testbeds: - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE. - SUT [Server-Type-B1]: - testbedname: testbed22. - hostname: s5-t22-sut1. @@ -896,6 +1064,10 @@ connectivity and wiring across defined CSIT testbeds: - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE. - SUT [Server-Type-B1]: - testbedname: testbed23. - hostname: s7-t23-sut1. @@ -920,6 +1092,10 @@ connectivity and wiring across defined CSIT testbeds: - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE. - SUT [Server-Type-B1]: - testbedname: testbed24. - hostname: s9-t24-sut1. @@ -944,6 +1120,10 @@ connectivity and wiring across defined CSIT testbeds: - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE. ``` #### 2-Node-Denverton Servers (2n-dnv) PROD @@ -1142,37 +1322,162 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD -Note: Server19 (TG) is shared between testbed33 & testbed34 +Note: Server19 (TG) is shared between testbed33 & testbed211 ``` -- SUT [Server-Type-B9]: - - testbedname: testbed34. - - hostname: s27-t34-sut1. +- SUT [Server-Type-E22]: + - testbedname: testbed211. + - hostname: s27-t211-sut1. - IPMI IP: 10.30.50.69 - Host IP: 10.30.51.69 - portnames: - - s27-t34-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t34-sut1-c6/p2 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t34-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t34-sut1-c18/p2 - 40GE-port1 XL710-QDA2-2p40GE. -- TG [Server-Type-B12]: - - testbedname: testbed33 and testbed34. - - hostname: s19-t33t34-tg1. + - s27-t211-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t211-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE. +- TG [Server-Type-E31]: + - testbedname: testbed33 and testbed211. + - hostname: s19-t33t211-tg1. - IPMI IP: 10.30.50.46 - Host IP: 10.30.51.49 - portnames: - - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE. - - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. +``` + +#### 2-Node-Icelake Servers (2n-icx) TBD + +``` +- SUT [Server-Type-F1]: + - testbedname: testbed212. + - hostname: s71-t212-sut1. + - IPMI IP: 10.30.51.81 + - Host IP: 10.30.50.81 + - portnames: + - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed212. + - hostname: s72-t212-tg1. + - IPMI IP: 10.30.51.82 + - Host IP: 10.30.50.82 + - portnames: + - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- SUT [Server-Type-F1]: + - testbedname: testbed213. + - hostname: s73-t213-sut1. + - IPMI IP: 10.30.51.83 + - Host IP: 10.30.50.83 + - portnames: + - s73-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s73-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s73-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s73-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s73-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s73-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s73-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s73-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed213. + - hostname: s74-t213-tg1. + - IPMI IP: 10.30.51.84 + - Host IP: 10.30.50.84 + - portnames: + - s74-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s74-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s74-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s74-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s74-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s74-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s74-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s74-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s74-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s74-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- SUT [Server-Type-F1]: + - testbedname: testbed214. + - hostname: s75-t214-sut1. + - IPMI IP: 10.30.51.85 + - Host IP: 10.30.50.85 + - portnames: + - s75-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s75-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s75-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s75-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s75-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s75-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s75-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s75-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed214. + - hostname: s76-t214-tg1. + - IPMI IP: 10.30.51.86 + - Host IP: 10.30.50.86 + - portnames: + - s76-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s76-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s76-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s76-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s76-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s76-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s76-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s76-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s76-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s76-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- SUT [Server-Type-F1]: + - testbedname: testbed215. + - hostname: s77-t215-sut1. + - IPMI IP: 10.30.51.87 + - Host IP: 10.30.50.87 + - portnames: + - s77-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s77-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s77-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s77-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s77-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s77-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s77-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s77-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed215. + - hostname: s78-t215-tg1. + - IPMI IP: 10.30.51.88 + - Host IP: 10.30.50.88 + - portnames: + - s78-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s78-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s78-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s78-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s78-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s78-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s78-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s78-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s78-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s78-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` #### 3-Node-Skylake Servers (3n-skx) PROD @@ -1190,8 +1495,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB12 [Server-Type-B1]: - testbedname: testbed31. - hostname: s12-t31-sut2. @@ -1204,8 +1507,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE. - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB13 [Server-Type-B2]: - testbedname: testbed31. - hostname: s13-t31-tg1. @@ -1218,8 +1519,10 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. + - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE. - ServerB14 [Server-Type-B1]: - testbedname: testbed32. - hostname: s14-t32-sut1. @@ -1232,8 +1535,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB15 [Server-Type-B1]: - testbedname: testbed32. - hostname: s15-t32-sut2. @@ -1246,8 +1547,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE. - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. - ServerB16 [Server-Type-B2]: - testbedname: testbed32. - hostname: s16-t32-tg1. @@ -1260,8 +1559,10 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. + - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE. ``` #### 3-Node-Rangeley Servers (3n-rng) VERIFY @@ -1300,10 +1601,10 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. #### 3-Node-Taishan Servers (3n-tsh) PROD -Note: Server19 (TG) is shared between testbed33 & testbed34 +Note: Server19 (TG) is shared between testbed33 & testbed211 ``` -- SUT [Server-Type-B3]: +- SUT [Server-Type-E21]: - testbedname: testbed33. - hostname: s17-t33-sut1. - IPMI IP: 10.30.50.36 @@ -1313,7 +1614,7 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE. - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE. - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE. -- SUT [Server-Type-B3]: +- SUT [Server-Type-E21]: - testbedname: testbed33. - hostname: s18-t33-sut2. - IPMI IP: 10.30.50.37 @@ -1323,24 +1624,59 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE. - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE. - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE. -- TG [Server-Type-B12]: - - testbedname: testbed33 and testbed34. - - hostname: s19-t33t34-tg1. +- TG [Server-Type-E31]: + - testbedname: testbed33 and testbed211. + - hostname: s19-t33t211-tg1. - IPMI IP: 10.30.50.46 - Host IP: 10.30.51.49 - portnames: - - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. - - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE. - - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. +``` + +#### 3-Node-Altra Servers (3n-alt) TBD + +Note: Server64 (TG) is shared between testbed34 & testbed36 + +``` +- SUT [Server-Type-E23]: + - testbedname: testbed34. + - hostname: s62-t34-sut1. + - IPMI IP: 10.30.50.72 + - Host IP: 10.30.51.72 + - portnames: + - s62-t34-sut1-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s62-t34-sut1-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s62-t34-sut1-ck/p1 - 100GE-port1 ConnectX5-2p100GE. + - s62-t34-sut1-ck/p2 - 100GE-port1 ConnectX5-2p100GE. +- SUT [Server-Type-E23]: + - testbedname: testbed34. + - hostname: s63-t34-sut2. + - IPMI IP: 10.30.50.73 + - Host IP: 10.30.51.73 + - portnames: + - s63-t34-sut2-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s63-t34-sut2-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s63-t34-sut2-ck/p1 - 100GE-port1 ConnectX5-2p100GE. + - s63-t34-sut2-ck/p2 - 100GE-port1 ConnectX5-2p100GE. +- TG [Server-Type-F4]: + - testbedname: testbed34. + - hostname: s64-t34t36-tg1. + - IPMI IP: 10.30.50.74 + - Host IP: 10.30.51.74 + - portnames: + - s64-t34-tg1-c1/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s64-t34-tg1-c1/p2 - 25GE-port2 xxv710-DA2-2p25GE. ``` #### 3-Node-Denverton Servers (3n-dnv) PROD @@ -1368,6 +1704,95 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port. ``` +#### 3-Node-Icelake Servers (3n-icx) TBD + +``` +- ServerF1 [Server-Type-F1]: + - testbedname: testbed37. + - hostname: s65-t37-sut1. + - IPMI IP: 10.30.50.75 + - Host IP: 10.30.51.75 + - portnames: + - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF1 [Server-Type-F1]: + - testbedname: testbed37. + - hostname: s66-t37-sut2. + - IPMI IP: 10.30.50.76 + - Host IP: 10.30.51.76 + - portnames: + - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF3 [Server-Type-F3]: + - testbedname: testbed37. + - hostname: s67-t37-tg1. + - IPMI IP: 10.30.50.77 + - Host IP: 10.30.51.77 + - portnames: + - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF1 [Server-Type-F1]: + - testbedname: testbed38. + - hostname: s68-t38-sut1. + - IPMI IP: 10.30.50.78 + - Host IP: 10.30.51.78 + - portnames: + - s68-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s68-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s68-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s68-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s68-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s68-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s68-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s68-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF1 [Server-Type-F1]: + - testbedname: testbed38. + - hostname: s69-t38-sut2. + - IPMI IP: 10.30.50.79 + - Host IP: 10.30.51.79 + - portnames: + - s69-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s69-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s69-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s69-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s69-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s69-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s69-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s69-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF3 [Server-Type-F3]: + - testbedname: testbed38. + - hostname: s70-t38-tg1. + - IPMI IP: 10.30.50.80 + - Host IP: 10.30.51.80 + - portnames: + - s70-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s70-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s70-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s70-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s70-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s70-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s70-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s70-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +``` + ### Per Testbed Wiring #### 1-Node-Skylake Wiring (1n-skx) PROD @@ -1404,39 +1829,25 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD ``` -- testbed36: +- testbed13: - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1. + - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1. - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2. + - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2. - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1. + - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1. - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2. + - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2. -- testbed37: +- testbed14: - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1. + - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1. - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2. + - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2. - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1. + - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1. - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: - - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2. -``` - -#### 1-Node-Cascadelake Wiring (1n-clx) PROD - -``` -- testbed14: - - ring1 10GE-ports x710-4p10GE: - - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1. - - ring2 10GE-ports x710-4p10GE: - - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2. - - ring3 10GE-ports x710-4p10GE: - - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3. - - ring4 10GE-ports x710-4p10GE: - - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3. + - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2. ``` #### 2-Node-Skylake Wiring (2n-skx) PROD @@ -1452,6 +1863,9 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1. - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2. + - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2. + - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4. - testbed22: - ring1 10GE-ports x710-4p10GE on SUT: - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1. @@ -1462,6 +1876,9 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1. - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2. + - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2. + - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4. - testbed23: - ring1 10GE-ports x710-4p10GE on SUT: - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1. @@ -1472,6 +1889,9 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1. - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2. + - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2. + - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4. - testbed24: - ring1 10GE-ports x710-4p10GE on SUT: - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1. @@ -1482,6 +1902,9 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1. - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2. + - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2. + - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4. ``` #### 2-Node-Denverton Wiring (2n-dnv) PROD @@ -1584,10 +2007,75 @@ Note: Server19 (TG) is shared between testbed33 & testbed34 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD ``` -- testbed34: +- testbed211: - ring1 10GE-ports x520-2p10GE on SUTs: - - s27-t34-sut1-c18/p1 - s19-t33t34-tg1-c8/p1. - - s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2. + - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1. + - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2. +``` + +#### 2-Node-Icelake Wiring (2n-icx) TBD + +``` +- testbed212: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1. + - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1. + - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2. + - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3. + - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1. + - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2. + - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1. +- testbed213: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s74-t213-tg1-c2/p1 to s73-t213-sut1-c2/p1. + - s73-t213-sut1-c2/p2 to s74-t213-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s74-t213-tg1-c4/p1 to s73-t213-sut1-c4/p1. + - s73-t213-sut1-c4/p2 to s74-t213-tg1-c4/p2. + - s74-t213-tg1-c4/p3 to s73-t213-sut1-c4/p3. + - s73-t213-sut1-c4/p4 to s74-t213-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s74-t213-tg1-c9/p1 to s73-t213-sut1-c9/p1. + - s73-t213-sut1-c9/p2 to s74-t213-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s74-t213-tg1-c6/p1 to s74-t213-tg1-c6/p2. + - s74-t213-tg1-c6/p2 to s74-t213-tg1-c6/p1. +- testbed214: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s76-t214-tg1-c2/p1 to s75-t214-sut1-c2/p1. + - s75-t214-sut1-c2/p2 to s76-t214-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s76-t214-tg1-c4/p1 to s75-t214-sut1-c4/p1. + - s75-t214-sut1-c4/p2 to s76-t214-tg1-c4/p2. + - s76-t214-tg1-c4/p3 to s75-t214-sut1-c4/p3. + - s75-t214-sut1-c4/p4 to s76-t214-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s76-t214-tg1-c9/p1 to s75-t214-sut1-c9/p1. + - s75-t214-sut1-c9/p2 to s76-t214-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s76-t214-tg1-c6/p1 to s76-t214-tg1-c6/p2. + - s76-t214-tg1-c6/p2 to s76-t214-tg1-c6/p1. +- testbed215: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s78-t215-tg1-c2/p1 to s77-t215-sut1-c2/p1. + - s77-t215-sut1-c2/p2 to s78-t215-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s78-t215-tg1-c4/p1 to s77-t215-sut1-c4/p1. + - s77-t215-sut1-c4/p2 to s78-t215-tg1-c4/p2. + - s78-t215-tg1-c4/p3 to s77-t215-sut1-c4/p3. + - s77-t215-sut1-c4/p4 to s78-t215-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s78-t215-tg1-c9/p1 to s77-t215-sut1-c9/p1. + - s77-t215-sut1-c9/p2 to s78-t215-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s78-t215-tg1-c6/p1 to s78-t215-tg1-c6/p2. + - s78-t215-tg1-c6/p2 to s78-t215-tg1-c6/p1. ``` #### 3-Node-Skylake Wiring (3n-skx) PROD @@ -1646,13 +2134,27 @@ To be completed. ``` - testbed33: - ring1 10GE-ports x520-2p10GE on SUTs: - - s19-t33t34-tg1-c2/p2 - s17-t33-sut1-c6/p2. + - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2. - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2. - - s18-t33-sut2-c6/p1 - s19-t33t34-tg1-c2/p1. + - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1. - ring2 25GE-ports cx4-2p25GE on SUTs: - - s19-t33t34-tg1-c4/p2 - s17-t33-sut1-c4/p2. + - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2. - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2. - - s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1. + - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1. +``` + +#### 3-Node-Altra Wiring (3n-alt) TBD + +``` +- testbed34: + - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs: + - s64-t34-tg1-cn/p2 - s62-t34-sut1-cn/p2. + - s62-t34-sut1-cn/p1 - s63-t34-sut2-cn/p2. + - s63-t34-sut2-cn/p1 - s64-t34-tg1-cn/p1. + - ring2 100GE-ports ConnectX5-2p100GE on SUTs: + - s64-t34-tg1-ck/p2 - s62-t34-sut1-ck/p2. + - s62-t34-sut1-ck/p1 - s63-t34-sut2-ckp2. + - s63-t34-sut2-ck/p1 - s64-t34-tg1-ck/p1. ``` #### 3-Node-Denverton Wiring (3n-dnv) PROD @@ -1669,6 +2171,43 @@ To be completed. - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4. ``` +#### 3-Node-Icelake Wiring (3n-icx) PROD + +``` +- testbed37: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: + - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1. + - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2. + - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: + - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1. + - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2. + - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2. + - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3. + - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4. + - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT + - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1. + - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2. + - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2. +- testbed38: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: + - s70-t38-tg1-c2/p1 to s68-t38-sut1-c2/p1. + - s68-t38-sut1-c2/p2 to s69-t38-sut2-c2/p2. + - s69-t38-sut2-c2/p1 to s70-t38-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: + - s70-t38-tg1-c4/p1 to s68-t38-sut1-c4/p1. + - s68-t38-sut1-c4/p2 to s69-t38-sut2-c4/p2. + - s69-t38-sut2-c4/p1 to s70-t38-tg1-c4/p2. + - s70-t38-tg1-c4/p3 to s68-t38-sut1-c4/p3. + - s68-t38-sut1-c4/p4 to s69-t38-sut2-c4/p4. + - s69-t38-sut2-c4/p3 to s70-t38-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT + - s70-t38-tg1-c9/p1 to s68-t38-sut1-c9/p1. + - s68-t38-sut1-c9/p2 to s69-t38-sut2-c9/p2. + - s69-t38-sut2-c9/p1 to s70-t38-tg1-c9/p2. +``` + ## Inventory ### Appliances @@ -1686,7 +2225,7 @@ To be completed. - Operating System: Native IxOS. ``` -### Arm Servers +### Arm Servers ``` 1. Arm Cortex A-72 servers @@ -1705,6 +2244,11 @@ To be completed. - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72. - RAM Memory: 8* 16GB DDR4-2400MT/s. - Disks: 1* 4TB SATA HDD. + - 2 * Ampere Altra + - Chassis: TBD + - Processors: TBD + - RAM Memory: TBD + - Disks: TBD ``` ### Xeon and Atom Servers