X-Git-Url: https://gerrit.fd.io/r/gitweb?p=csit.git;a=blobdiff_plain;f=docs%2Flab%2Ftestbed_specifications.md;h=93061770111cd75097394fbba90b7fe8dab371c7;hp=5a8b4b1137a7057b61024bdb9660298d43d23844;hb=7b06cddf4f0ceca580b71b695e34a39e706931fc;hpb=6e96fee163eb9622bf39ed48743db86f7bcf743a diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index 5a8b4b1137..9306177011 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -5,44 +5,63 @@ 1. [Summary List](#summary-list) 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx) 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2) + 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx) 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx) 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv) 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1) - 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx) + 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx) + 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn) + 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2) + 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx) 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx) - 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) - 1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell) 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds) + 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) + 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt) + 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx) + 1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr) 1. [Server Management](#server-management) 1. [Requirements](#requirements) 1. [Addressing](#addressing) 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses) 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses) -1. [Server Type Specification](#server-type-specification) - 1. [Server and Port Naming](#server-and-port-naming) +1. [Server Specifications](#server-specifications) + 1. [Server Types](#server-types) + 1. [Naming Convention](#naming-convention) 1. [Testbeds Configuration](#testbeds-configuration) 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming) - 1. [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod) - 1. [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip) - 1. [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod) - 1. [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo) - 1. [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify) - 1. [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod) - 1. [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod) - 1. [3-Node-Rangeley (3n-rng) VERIFY](#3-node-rangeley-3n-rng-verify) - 1. [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip) - 1. [3-Node-Mcbin (3n-mcb) TODO](#3-node-mcbin-3n-mcb-todo) + 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod) + 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod) + 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod) + 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod) + 1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod) + 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify) + 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod) + 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod]) + 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod) + 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod) + 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod) + 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify) + 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod) + 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod) + 1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod) + 1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod) 1. [Per Testbed Wiring](#per-testbed-wiring) - 1. [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod) - 1. [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip) - 1. [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod) - 1. [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo) - 1. [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify) - 1. [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod) - 1. [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod) - 1. [3-Node-Rangeley (3n-rng) TODO](#3-node-rangeley-3n-rng-todo) - 1. [3-Node-Taishan (3n-tsh) WIP](#3-node-taishan-3n-tsh-wip) - 1. [3-Node-Mcbin (3n-mcb) WIP](#3-node-mcbin-3n-mcb-wip) + 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod) + 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod) + 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod) + 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod) + 1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod) + 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify) + 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod) + 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod]) + 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod) + 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod) + 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod) + 1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo) + 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod) + 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod) + 1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod) + 1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod) 1. [Inventory](#inventory) 1. [Appliances](#appliances) 1. [Arm Servers](#arm-servers) @@ -61,81 +80,146 @@ hosted by LFN FD.io CSIT project. ### Summary List ``` - #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb - 1. 1-Node-Skylake func skx na 2 2 0 0 2 0 0 0 0 0 0 - 2. 1-Node-Thunderx2 func tx2 na 1 1 0 0 0 0 0 0 1 0 0 - 3. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 - 4. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 - 5. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 - 6. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 - 7. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 - 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 - 9. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0 -10. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2 -11. 1-Node-VIRL func hsw --- 3 3 0 3 0 0 0 0 0 0 0 - Totals: 17 26 14 12 19 1 2 1 1 2 2 + #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx #snr + 1. 1-Node-Haswell nomad hsw na 4 4 0 4 0 0 0 0 0 0 0 0 0 0 0 + 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0 0 0 + 3. 1-Node-ThunderX2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 0 + 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0 0 0 + 5. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 0 0 2 0 0 0 0 + 6. 2-Node-Skylake perf skx skx 3 3 3 0 6 0 0 0 0 0 0 0 0 0 0 + 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0 0 0 + 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0 0 0 + 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0 0 0 +10. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 0 .5 0 0 0 1 0 0 0 0 0 0 +11. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0 +12. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0 0 0 +13. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0 0 0 +14. 3-Node-Taishan perf tsh skx 1 2 .5 0 .5 0 0 0 0 2 0 0 0 0 0 +15. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 0 0 2 0 0 1 0 +16. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0 0 0 +17. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2 0 0 +18. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 0 0 6 0 +19. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 0 0 .5 2 + Totals: 34 44 21.5 4 17 1 2 3 3 2 4 7 2 15.5 2 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) -Each 1-Node-Skylake testbed includes one SUT (Type-B6 server) with NIC -ports connected back-to-back. +Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC +ports connected back-to-back ([Server Types](#server-types)). Used for FD.io VPP_Device functional driver tests. ### 1-Node-ThunderX2 Arm Marvell (1n-tx2) -Each 1-Node-ThunderX2 testbed includes one SUT (Type-B9 server) with NIC -ports connected back-to-back. +Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC +ports connected back-to-back ([Server Types](#server-types)). +Used for FD.io VPP_Device functional driver tests. + +### 1-Node-Cascadelake Xeon Intel (1n-clx) + +Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with +NIC ports connected back-to-back ([Server Types](#server-types)). + Used for FD.io VPP_Device functional driver tests. ### 2-Node-Skylake Xeon Intel (2n-skx) -Each 2-Node-Skylake testbed includes one SUT (Type-B1 server) and one TG -(Type-B2 server) connected back-to-back. +Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG +(Server-Type-B2) connected in a 2-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. ### 2-Node-Denverton Atom Intel (2n-dnv) -Each 2-Node-Skylake testbed includes one SUT (Type-B10 server) and one TG -(Type-B2 server) connected back-to-back. +Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one +TG (Server-Type-B2) connected in a 2-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1) -Each 2-Node-IxiaPS1L47 testbed includes one SUT (Type-B1 server) and one -TG (Ixia PSOne appliance) with 10GE interfaces connected back-to-back. +Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one +TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node +circular topology ([Server Types](#server-types)). Used for FD.io TCP/IP and HTTP performance tests. +### 2-Node-Cascadelake Xeon Intel (2n-clx) + +Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and +one TG (Server-Type-C3) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 2-Node-Zen2 EPYC AMD (2n-zn2) + +Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and +one TG (Server-Type-D2) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 2-Node-ThunderX2 Arm Marvell (2x-tx2) + +Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and +one TG (Server-Type-E31) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + +### 2-Node-Icelake Xeon Intel (2n-icx) + +Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and +one TG (Server-Type-F2) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + ### 3-Node-Haswell Xeon Intel (3n-hsw) -Each 3-Node-Haswell testbed includes two SUTs (Type-A1 servers) and one -TG (Type-A2 server) connected in full-mesh triangle. +Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one +TG (Server-Type-A2) connected in a 3-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. ### 3-Node-Skylake Xeon Intel (3n-skx) -Each 3-Node-Skylake testbed includes two SUTs (Type-B1 servers) and one -TG (Type-B2 server) connected in full-mesh triangle. +Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one +TG (Server-Type-B2) connected in a 3-node circular topology. +Used for FD.io performance tests. + +### 3-Node-Rangeley Atom Testbeds + +Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one +TG (Server-Type-2) connected in a 3-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. ### 3-Node-TaiShan Arm Huawei (3n-tsh) -Each 3-Node-TaiShan testbed includes two SUTs (Type-B3 server) and one TG -(Type-B2 server) connected in full-mesh triangle. +Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one +TG (Server-Type-E31) connected in a 3-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. -### 3-Node-MACCHIATObin Arm Marvell +### 3-Node-Altra Arm Ampere (3n-alt) -Each 3-Node-MACCHIATObin testbed includes two SUTs (Type-B4 server) and -one TG (Type-B2 server) connected in full-mesh triangle. +Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one +TG (Server-Type-F4) connected in a 3-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. -### 3-Node-Rangeley Atom Testbeds +### 3-Node-Icelake Xeon Intel (3n-icx) + +Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one +TG (Server-Type-F3) connected in a 3-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. -Each 3-Node-Rangeley testbed includes two SUTs (Type-B5 Netgate device) -and one TG (Type-2 server) connected in full-mesh triangle. +### 3-Node-SnowRidge Atom Intel (3n-snr) + +Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one +TG (Server-Type-F4) connected in a 3-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. + ## Server Management ### Requirements @@ -146,16 +230,16 @@ connected to the management network: ``` - 1GE IPMI port - IPMI - Intelligent Platform Management Interface. - - Required for access to embedded server management with WebUI, CLI, SNMPv3, - IPMIv2.0, for firmware (BIOS) and OS updates. + - Required for access to embedded server management with WebUI, CLI, + SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates. - 1GE/10GE/40GE management port - hostOS management port for general system management. ``` ### Addressing -Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management -port, which are connected to two different VLANs. +Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a +Management port, which are connected to two different VLANs. ``` 1. LOM (IPMI) VLAN: @@ -194,26 +278,27 @@ Name | Comment 10.30.50.13 | LF Reserved 10.30.50.14 | LF Reserved 10.30.50.15 | LF Reserved -10.30.50.16 | t1-tg1 -10.30.50.17 | t1-sut1 -10.30.50.18 | t1-sut2 -10.30.50.20 | t2-tg1 -10.30.50.21 | t2-sut1 -10.30.50.22 | t2-sut2 -10.30.50.24 | t3-tg1 -10.30.50.25 | t3-sut1 -10.30.50.26 | t3-sut-2 -10.30.50.28 | t4-sut1 -10.30.50.29 | t4-sut2 -10.30.50.30 | t4-sut3 +10.30.50.22 | s42-nomad +10.30.50.24 | s43-nomad +10.30.50.25 | s44-nomad +10.30.50.26 | s45-nomad +10.30.50.28 | s41-nomad +10.30.50.29 | s39-nomad +10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0 +10.30.50.30 | s40-nomad +10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1 +10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2 10.30.50.36 | s17-t33-sut1 10.30.50.37 | s18-t33-sut2 +10.30.50.38 | fdio-marvell-dev +10.30.50.39 | s53-nomad +10.30.50.40 | s54-nomad 10.30.50.41 | s3-t21-sut1 10.30.50.42 | s4-t21-tg1 10.30.50.43 | s11-t31-sut1 10.30.50.44 | s12-t31-sut2 10.30.50.45 | s13-t31-tg1 -10.30.50.46 | s19-t33t34-tg1 +10.30.50.46 | s19-t33t211-tg1 10.30.50.47 | s1-t11-sut1 10.30.50.48 | s2-t12-sut1 10.30.50.49 | s5-t22-sut1 @@ -227,78 +312,160 @@ Name | Comment 10.30.50.57 | s16-t32-tg1 10.30.50.58 | s25-t25-sut1 10.30.50.59 | s26-t25-tg1 -10.30.50.69 | s27-t13-sut +10.30.50.65 | s52-nomad +10.30.50.66 | s51-nomad +10.30.50.67 | s49-nomad +10.30.50.68 | s50-nomad +10.30.50.69 | s27-t211-sut1 +10.30.50.70 | s55-t13-sut1 +10.30.50.71 | s56-t14-sut1 +10.30.50.72 | s62-t34-sut1 +10.30.50.73 | s63-t34-sut2 +10.30.50.74 | s64-t34-tg1 +10.30.50.75 | s65-t37-sut1 +10.30.50.76 | s66-t37-sut2 +10.30.50.77 | s67-t37-tg1 +10.30.50.78 | s78-t38-sut1 +10.30.50.79 | s79-t38-sut2 +10.30.50.80 | s80-t38-tg1 +10.30.50.81 | s71-t212-sut1 +10.30.50.82 | s72-t212-tg1 +10.30.50.83 | s83-t213-sut1 +10.30.50.84 | s84-t213-tg1 +10.30.50.85 | s85-t214-sut1 +10.30.50.86 | s86-t214-tg1 +10.30.50.87 | s87-t215-sut1 +10.30.50.88 | s88-t215-tg1 +10.30.50.89 | s89-t39t310-tg1 +10.30.50.90 | s90-t311t312-tg1 +10.30.50.91 | s58-nomad +10.30.50.92 | s59-nomad +10.30.50.93 | s93-t39-sut1 +10.30.50.94 | s94-t39-sut2 10.30.50.255 | Broadcast +10.30.55.0 | network +10.30.55.1 | Router +10.30.55.10 | s28-t26t35-tg1 +10.30.55.11 | s29-t26-sut1 +10.30.55.12 | s30-t35-sut1 +10.30.55.13 | s31-t35-sut2 +10.30.55.14 | s46-nomad +10.30.55.15 | s47-nomad +10.30.55.16 | s48-nomad +10.30.55.17 | s57-nomad +10.30.55.18 | s33-t27-sut1 +10.30.55.19 | s34-t27-tg1 +10.30.55.20 | s35-t28-sut1 +10.30.55.21 | s36-t28-tg1 +10.30.55.22 | s37-t29-sut1 +10.30.55.23 | s38-t29-tg1 +10.30.55.24 | s60-t210-sut1 +10.30.55.25 | s61-t210-tg1 +10.30.55.255 | Broadcast ### Management VLAN IP Addresses -Name | Comment -------------------------- | ------- -10.30.51.0 | network -10.30.51.1 | Router -10.30.51.2 | LF Reserved -10.30.51.3 | LF Reserved -10.30.51.4 | LF Reserved -10.30.51.5 | LF Reserved -10.30.51.6 | LF Reserved -10.30.51.7 | LF Reserved -10.30.51.8 | LF Reserved -10.30.51.9 | s22-t35-sut1 (netgate-1) -10.30.51.10 | s23-t35-sut2 (netgate-2) -10.30.51.11 | s24-t35-sut3 (netgate-3) -10.30.51.12 | softiron-1 -10.30.51.13 | softiron-2 -10.30.51.14 | softiron-3 -10.30.51.15 | LF Reserved -10.30.51.16 | t1-tg1 -10.30.51.17 | t1-sut1 -10.30.51.18 | t1-sut2 -10.30.51.20 | t2-tg1 -10.30.51.21 | t2-sut1 -10.30.51.22 | t2-sut2 -10.30.51.24 | t3-tg1 -10.30.51.25 | t3-sut1 -10.30.51.26 | t3-sut-2 -10.30.51.28 | t4-sut1 -10.30.51.29 | t4-sut2 -10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0, TO BE VERIFIED -10.30.51.30 | t4-sut3 -10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1, TO BE VERIFIED -10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2, TO BE VERIFIED -10.30.51.36 | s17-t33-sut1 -10.30.51.37 | s18-t33-sut2 -10.30.51.41 | s20-t34-sut1 -10.30.51.42 | s21-t34-sut2 -10.30.51.44 | s3-t21-sut1 -10.30.51.45 | s4-t21-tg1 -10.30.51.46 | s11-t31-sut1 -10.30.51.47 | s12-t31-sut2 -10.30.51.48 | s13-t31-tg1 -10.30.51.49 | s19-t33t34-tg1 -10.30.51.50 | s1-t11-sut1 -10.30.51.51 | s2-t12-sut1 -10.30.51.52 | s5-t22-sut1 -10.30.51.53 | s6-t22-tg1 -10.30.51.54 | s7-t23-sut1 -10.30.51.55 | s8-t23-tg1 -10.30.51.56 | s9-t24-sut1 -10.30.51.57 | s10-t24-tg1 -10.30.51.58 | s14-t32-sut1 -10.30.51.59 | s15-t32-sut2 -10.30.51.60 | s16-t32-tg1 -10.30.51.61 | s25-t25-sut1 -10.30.51.62 | s26-t25-tg1 -10.30.51.69 | s27-t13-sut1 -10.30.51.70-10.30.51.105 | VIRL1 TO BE VERIFIED -10.30.51.106-10.30.51.180 | VIRL2 -10.30.51.181-10.30.51.254 | VIRL3 -10.30.51.255 | Broadcast - -## Server Type Specification +Name | Comment +-------------| ------- +10.30.51.0 | network +10.30.51.1 | Router +10.30.51.2 | LF Reserved +10.30.51.3 | LF Reserved +10.30.51.4 | LF Reserved +10.30.51.5 | LF Reserved +10.30.51.6 | LF Reserved +10.30.51.7 | LF Reserved +10.30.51.8 | LF Reserved +10.30.51.15 | LF Reserved +10.30.51.22 | s42-nomad +10.30.51.24 | s43-nomad +10.30.51.25 | s44-nomad +10.30.51.26 | s45-nomad +10.30.51.28 | s41-nomad +10.30.51.29 | s39-nomad +10.30.51.30 | s40-nomad +10.30.51.36 | s17-t33-sut1 +10.30.51.37 | s18-t33-sut2 +10.30.51.38 | fdio-marvell-dev +10.30.51.39 | s53-nomad +10.30.51.40 | s54-nomad +10.30.51.44 | s3-t21-sut1 +10.30.51.45 | s4-t21-tg1 +10.30.51.46 | s11-t31-sut1 +10.30.51.47 | s12-t31-sut2 +10.30.51.48 | s13-t31-tg1 +10.30.51.49 | s19-t33t211-tg1 +10.30.51.50 | s1-t11-sut1 +10.30.51.51 | s2-t12-sut1 +10.30.51.52 | s5-t22-sut1 +10.30.51.53 | s6-t22-tg1 +10.30.51.54 | s7-t23-sut1 +10.30.51.55 | s8-t23-tg1 +10.30.51.56 | s9-t24-sut1 +10.30.51.57 | s10-t24-tg1 +10.30.51.58 | s14-t32-sut1 +10.30.51.59 | s15-t32-sut2 +10.30.51.60 | s16-t32-tg1 +10.30.51.61 | s25-t25-sut1 +10.30.51.62 | s26-t25-tg1 +10.30.51.65 | s52-nomad +10.30.51.66 | s51-nomad +10.30.51.67 | s49-nomad +10.30.51.68 | s50-nomad +10.30.51.69 | s27-t211-sut1 +10.30.51.70 | s55-t13-sut1 +10.30.51.71 | s56-t14-sut1 +10.30.51.72 | s62-t34-sut1 +10.30.51.73 | s63-t34-sut2 +10.30.51.74 | s64-t34-tg1 +10.30.51.75 | s65-t37-sut1 +10.30.51.76 | s66-t37-sut2 +10.30.51.77 | s67-t37-tg1 +10.30.51.78 | s78-t38-sut1 +10.30.51.79 | s79-t38-sut2 +10.30.51.80 | s80-t38-tg1 +10.30.51.81 | s71-t212-sut1 +10.30.51.82 | s72-t212-tg1 +10.30.51.83 | s83-t213-sut1 +10.30.51.84 | s84-t213-tg1 +10.30.51.85 | s85-t214-sut1 +10.30.51.86 | s86-t214-tg1 +10.30.51.87 | s87-t215-sut1 +10.30.51.88 | s88-t215-tg1 +10.30.51.89 | s89-t39t310-tg1 +10.30.51.90 | s90-t311t312-tg1 +10.30.51.91 | s58-nomad +10.30.51.92 | s59-nomad +10.30.51.93 | s93-t39-sut1 +10.30.51.94 | s94-t39-sut2 +10.30.51.255 | Broadcast +10.32.8.0 | network +10.32.8.1 | Router +10.32.8.10 | s28-t26t35-tg1 +10.32.8.11 | s29-t26-sut1 +10.32.8.12 | s30-t35-sut1 +10.32.8.13 | s31-t35-sut2 +10.32.8.14 | s46-nomad +10.32.8.15 | s47-nomad +10.32.8.16 | s48-nomad +10.32.8.17 | s57-nomad +10.32.8.18 | s33-t27-sut1 +10.32.8.19 | s34-t27-tg1 +10.32.8.20 | s35-t28-sut1 +10.32.8.21 | s36-t28-tg1 +10.32.8.22 | s37-t29-sut1 +10.32.8.23 | s38-t29-tg1 +10.32.8.24 | s60-t210-sut1 +10.32.8.25 | s61-t210-tg1 +10.32.8.255 | Broadcast + +## Server Specifications + +### Server Types FD.io CSIT lab contains following server types: ``` -1. Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing. +1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing. - Quantity: 6 servers. - Physical connectivity: - CIMC and host management ports. @@ -310,15 +477,15 @@ FD.io CSIT lab contains following server types: - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD. - NICs configuration: - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes) - - PCIe Slot1: Cisco VIC 1385 2p40GE. - - PCIe Slot2: Intel NIC x520 2p10GE. + - PCIe Slot1: empty. + - PCIe Slot2: empty. - PCIe Slot3: empty. - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes) - - PCIe Slot4: Intel NIC xl710 2p40GE. - - PCIe Slot5: Intel NIC x710 2p10GE. - - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill) + - PCIe Slot4: empty. + - PCIe Slot5: empty. + - PCIe Slot6: empty - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes). -2. Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing. +2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing. - Quantity: 3 servers. - Physical connectivity: - CIMC and host management ports. @@ -329,16 +496,16 @@ FD.io CSIT lab contains following server types: - RAM Memory: 16* 32GB DDR4-2133MHz. - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD. - NICs configuration: - - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes) - - PCIe Slot1: Intel NIC xl710 2p40GE. - - PCIe Slot2: Intel NIC x710 2p10GE. - - PCIe Slot3: Intel NIC x710 2p10GE. - - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes) - - PCIe Slot4: Intel NIC xl710 2p40GE. - - PCIe Slot5: Intel NIC x710 2p10GE. - - PCIe Slot6: Intel NIC x710 2p10GE. + - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes) + - PCIe Slot1: empty. + - PCIe Slot2: empty. + - PCIe Slot3: empty. + - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes) + - PCIe Slot4: empty. + - PCIe Slot5: empty. + - PCIe Slot6: empty - MLOM slot: empty. -3. Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing. +3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing. - Quantity: 3 servers. - Physical connectivity: - CIMC and host management ports. @@ -354,7 +521,7 @@ FD.io CSIT lab contains following server types: - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes) - no cards. - MLOM slot: empty. -4. Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing. +4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing. - Quantity: --- - Physical connectivity: - IPMI and host management ports. @@ -362,19 +529,19 @@ FD.io CSIT lab contains following server types: - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox. + - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -2. Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing. +5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing. - Quantity: --- - Physical connectivity: - IPMI and host management ports. @@ -382,44 +549,19 @@ FD.io CSIT lab contains following server types: - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox. + - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. -3. Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. - - Quantity: 2 - - Physical connectivity: - - IPMI(?) and host management ports. - - NIC ports connected into 3-node topology. - - Main HW configuration: - - Chassis: Huawei TaiShan 2280. - - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72 - - RAM Memory: 8* 16GB DDR4-2400MT/s - - Disks: 1* 4TB SATA HDD - - NICs configuration: - - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. - - PCIe Slot6 11:00.xx: x520-2p10GE Intel. -4. Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing. - - Quantity: 3 - - Physical connectivity: - - Host management ports. - - NIC ports connected into 2-node and 3-node topologies. - - Main HW configuration: - - Chassis: MACCHIATObin. - - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72 - - RAM Memory: 1* 16GB DDR4 - - Disks: 1* 128GB(?) SATA SDD - - NICs configuration: - - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP) -5. Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing. +6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing. - Quantity: TBD based on testbed allocation. - Physical connectivity: - Management: serial Port (usb) for console @@ -432,15 +574,15 @@ FD.io CSIT lab contains following server types: - NICs configuration: - 2x 10Gb Intel 82599ES - 4x 1GB Intel I354 -6. Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. +7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. - - NIC ports connected into 2-node and 3-node topologies. + - NIC ports connected into 1-node topologies. - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: @@ -452,7 +594,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -7. Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. +8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. - Quantity: 1. - Physical connectivity: - Host management interface: 10/100/1000-BaseT. @@ -471,7 +613,7 @@ FD.io CSIT lab contains following server types: - Port-2: 10GE SFP+. - Port-3: 10GE SFP+. - Port-4: 10GE SFP+. -8. Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. +9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -479,7 +621,7 @@ FD.io CSIT lab contains following server types: - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: @@ -491,40 +633,318 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -9. Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. - - Quantity: 1 +10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing. + - Quantity: 4 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports. + - Main HW configuration: + - Chassis: SuperMicro SYS-E300-9A + - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz + - RAM Memory: 32GB ECC + - Disks: 480 GB + - NICs configuration: + - 2x 10Gb Intel x553 fiber ports + - 2x 10Gb Intel x553 copper ports + - 4x 1GB Intel I350 ports +11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 1-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8280 2.7 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 2* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing. + - Quantity: 3 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Gold 6252N 2.3 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 2* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: e810-2p100GE Intel. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8280 2.7 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 2* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. + - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox. + - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox. + - PCIe Slot10 d8:00.xx: empty. +14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - no NIC ports, standalone setup. + - Main HW configuration: + - Chassis: SuperMicro 1029P-WTRT. + - Motherboard: SuperMicro X11DDW-NT. + - Processors: 2* Intel Platinum 8280 2.7 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 4* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: + - no cards. + - Numa1: + - no cards. +15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro AS-1114S-WTRT + - Processors: 1* AMD EPYC 7532 2.4 GHz. + - RAM Memory: 8* 32GB DDR4-2933. + - Disks: 1* 1TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot1 01:00.xx: x710-4p10GE Intel. + - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. +16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro AS-1114S-WTRT + - Processors: 1* AMD EPYC 7532 2.4 GHz. + - RAM Memory: 8* 32GB DDR4-2933. + - Disks: 1* 1TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox. + - PCIe Slot2 41:00.xx: x710-4p10GE Intel. + - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel. +17. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. + - Quantity: 2 - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 1-node topologies. + - Main HW configuration: + - Chassis: GIGABYTE Rack Mount + - Motherboard: MT91-FS4-00 + - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz + - RAM Memory: 16 * 16GB DIMM + - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480 + - NICs configuration: + - Numa0: + - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox. + - Numa1: + - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox. +18. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. + - Quantity: 2 + - Physical connectivity: + - IPMI(?) and host management ports. + - NIC ports connected into 3-node topology. + - Main HW configuration: + - Chassis: Huawei TaiShan 2280. + - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72 + - RAM Memory: 8* 16GB DDR4-2400MT/s + - Disks: 1* 4TB SATA HDD + - NICs configuration: + - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. + - PCIe Slot6 11:00.xx: x520-2p10GE Intel. +19. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing. + - Quantity: 1 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node topologies. - Main HW configuration: - Chassis: Gigabyte R181-T90 1U - - Motheboard: MT91-FS1 - - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz + - Motherboard: MT91-FS1 + - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz - RAM Memory: 4* 32GB RDIMM - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - NICs configuration: - Numa0: - - PCIe Slot1 05:00.xx: XL710-QDA2. - - PCIe Slot3 08:00.xx: XL710-QDA2. + - no cards - Numa1: - - PCIe Slot6 85:00.xx: XL710-QDA2. -10. Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing. - - Quantity: 4 + - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel. +20. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing. + - Quantity: 2 - Physical connectivity: - IPMI and host management ports. - - NIC ports. + - NIC ports connected into 3-node topologies. - Main HW configuration: - - Chassis: SuperMicro SYS-E300-9A - - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz - - RAM Memory: 32GB ECC - - Disks: 480 GB + - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U + - Motherboard: Mt.Jade Motherboard + - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1 + - RAM Memory: 16* 8GB DDR4-3200MT/s + - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983 - NICs configuration: - - 2x 10Gb Intel x553 fiber ports - - 2x 10Gb Intel x553 copper ports - - 4x 1GB Intel I350 ports + - Numa0: + - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel. + - Numa1: + - no cards. +21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build. + - Quantity: 2. + - Physical connectivity: + - IPMI and host management ports. + - Main HW configuration: + - Chassis: Gigabyte R152-P30-00 1U + - Motherboard: MP32-AR1-00 + - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1 + - RAM Memory: 12* 16GB DDR4-3200MT/s + - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 +22. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing. + - Quantity: 1 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and 3-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.5 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel. + - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. +23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing. + - Quantity: 8. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node or 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and/or 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: empty. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot10 d8:00.xx: empty. +27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing. + - Quantity: 2 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 3-node testbed topology. + - Main HW configuration: + - Chassis: ?. + - Motherboard: ?. + - Processors: ?* Intel Atom P5362B 2.2 GHz. + - RAM Memory: ?* ?GB DDR4-2933. + - Disks: ?* ? SATA SSD. + - NICs configuration: + - Numa0: (x16, PCIe3.0 lane) + - PCIe Slot yy:00.xx: ?. ``` -### Server and Port Naming +### Naming Convention Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds: @@ -549,10 +969,10 @@ connectivity and wiring across defined CSIT testbeds: ### Per Testbed Server Allocation and Naming -#### 1-Node-Skylake (1n-skx) PROD +#### 1-Node-Skylake Servers (1n-skx) PROD ``` -- ServerB1 [Type-B6]: +- SUT [Server-Type-B6]: - testbedname: testbed11. - hostname: s1-t11-sut1. - IPMI IP: 10.30.50.47 @@ -566,7 +986,7 @@ connectivity and wiring across defined CSIT testbeds: - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE. -- ServerB2 [Type-B6]: +- SUT [Server-Type-B6]: - testbedname: testbed12. - hostname: s2-t12-sut1. - IPMI IP: 10.30.50.48 @@ -582,27 +1002,62 @@ connectivity and wiring across defined CSIT testbeds: - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE. ``` -#### 1-Node-Thunderx2 (1n-tx2) WIP +#### 1-Node-ThunderX2 Servers (1n-tx2) PROD ``` -- ServerB17 [Type-B9]: - - testbedname: testbed13. - - hostname: s27-t13-sut1. - - IPMI IP: 10.30.50.69 - - Host IP: 10.30.51.69 +- SUT [Server-Type-E11]: + - testbedname: testbed13 + - hostname: s55-t13-sut1 + - IPMI IP: 10.30.50.70 + - Host IP: 10.30.51.70 + - portnames: + - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. + - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. +- SUT [Server-Type-E11]: + - testbedname: testbed14 + - hostname: s56-t14-sut1 + - IPMI IP: 10.30.50.71 + - Host IP: 10.30.51.71 + - portnames: + - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. + - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox. + - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox. +``` + +#### 1-Node-Cascadelake Servers (1n-clx) PROD + +``` +- SUT [Server-Type-C1]: + - testbedname: testbed11. + - hostname: s32-t14-sut1. + - IPMI IP: 10.30.55.17 + - Host IP: 10.32.8.17 - portnames: - - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE. - - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE. - - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE. + - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE. + - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE. + - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE. + - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE. ``` -#### 2-Node-Skylake (2n-skx) PROD +#### 2-Node-Skylake Servers (2n-skx) PROD ``` -- ServerB3 [Type-B1]: +- SUT [Server-Type-B1]: - testbedname: testbed21. - hostname: s3-t21-sut1. - IPMI IP: 10.30.50.41 @@ -614,9 +1069,7 @@ connectivity and wiring across defined CSIT testbeds: - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB4 [Type-B2]: +- TG [Server-Type-B2]: - testbedname: testbed21. - hostname: s4-t21-tg1. - IPMI IP: 10.30.50.42 @@ -628,9 +1081,11 @@ connectivity and wiring across defined CSIT testbeds: - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB5 [Type-B1]: + - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE. +- SUT [Server-Type-B1]: - testbedname: testbed22. - hostname: s5-t22-sut1. - IPMI IP: 10.30.50.49 @@ -642,9 +1097,7 @@ connectivity and wiring across defined CSIT testbeds: - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB6 [Type-B2]: +- TG [Server-Type-B2]: - testbedname: testbed22. - hostname: s6-t22-tg1. - IPMI IP: 10.30.50.50 @@ -656,9 +1109,11 @@ connectivity and wiring across defined CSIT testbeds: - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB7 [Type-B1]: + - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE. +- SUT [Server-Type-B1]: - testbedname: testbed23. - hostname: s7-t23-sut1. - IPMI IP: 10.30.50.51 @@ -670,9 +1125,7 @@ connectivity and wiring across defined CSIT testbeds: - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB8 [Type-B2]: +- TG [Server-Type-B2]: - testbedname: testbed23. - hostname: s8-t23-tg1. - IPMI IP: 10.30.50.52 @@ -684,9 +1137,11 @@ connectivity and wiring across defined CSIT testbeds: - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB9 [Type-B1]: + - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE. +- SUT [Server-Type-B1]: - testbedname: testbed24. - hostname: s9-t24-sut1. - IPMI IP: 10.30.50.53 @@ -698,9 +1153,7 @@ connectivity and wiring across defined CSIT testbeds: - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB10 [Type-B2]: +- TG [Server-Type-B2]: - testbedname: testbed24. - hostname: s10-t24-tg1. - IPMI IP: 10.30.50.54 @@ -712,20 +1165,51 @@ connectivity and wiring across defined CSIT testbeds: - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. + - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE. ``` -#### 2-Node-Denverton (2n-dnv) TODO +#### 2-Node-Denverton Servers (2n-dnv) PROD + +Note: ServerB28 (TG) is shared between testbed26 & testbed35 ``` -To be completed. +- TG [Server-Type-B2]: + - testbednames: testbed26 and testbed35. + - hostname: s28-t26t35-tg1. + - IPMI IP: 10.30.55.10 + - Host IP: 10.32.8.10 + - portnames: + - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE. + - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE. + - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE. + - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE. + - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE. + - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE. + - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE. + - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE. + - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE. + - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE. + - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE. + - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE. +- SUT [Server-Type-B10]: + - testbednames: testbed26. + - hostname: s29-t26-sut1. + - IPMI IP: 10.30.55.11 + - Host IP: 10.32.8.11 + - portnames: + - s29-t26-sut1-p1 - 10GE-port1 x553 copper port. + - s29-t26-sut1-p2 - 10GE-port2 x553 copper port. + - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port. + - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port. ``` -#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY +#### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY ``` -- ServerB25 [Type-B8]: +- SUT [Server-Type-B8]: - testbedname: testbed25. - hostname: s25-t25-sut1. - IPMI IP: 10.30.50.58 @@ -735,7 +1219,7 @@ To be completed. - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE. -- ServerB26 [Type-B7]: +- TG [Server-Type-B7]: - testbedname: testbed25. - hostname: s26-t25-tg1. - IPMI IP: 10.30.50.59 @@ -747,165 +1231,306 @@ To be completed. - s26-t25-tg1-p4 - 10GE-port4. ``` -#### 3-Node-Haswell (3n-hsw) PROD +#### 2-Node-Cascadelake Servers (2n-clx) PROD ``` - 1. Server1 of Type-1: - - testbedname: testbed1. - - hostname: t1-sut1. - - CIMC IP: 10.30.50.17 - - Host IP: 10.30.51.17 +- SUT [Server-Type-C2]: + - testbedname: testbed27. + - hostname: s33-t27-sut1. + - IPMI IP: 10.30.55.18 + - Host IP: 10.32.8.18 - portnames: - - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 2. Server2 of Type-1: - - testbedname: testbed1. - - hostname: t1-sut2. - - CIMC IP: 10.30.50.18 - - Host IP: 10.30.51.18 + - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE. + - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-C3]: + - testbedname: testbed27. + - hostname: s34-t27-tg1. + - IPMI IP: 10.30.55.19 + - Host IP: 10.32.8.19 - portnames: - - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 3. Server3 of Type-2: - - testbedname: testbed1. - - hostname: t1-tg1. - - CIMC IP: 10.30.50.16 - - Host IP: 10.30.51.16 + - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. + - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. + - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. + - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- SUT [Server-Type-C2]: + - testbedname: testbed28. + - hostname: s35-t28-sut1. + - IPMI IP: 10.30.55.20 + - Host IP: 10.32.8.20 - portnames: - - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. - 4. Server4 of Type-1: - - testbedname: testbed2. - - hostname: t2-sut1. - - CIMC IP: 10.30.50.21 - - Host IP: 10.30.51.21 + - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE. + - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-C3]: + - testbedname: testbed28. + - hostname: s36-t28-tg1. + - IPMI IP: 10.30.55.21 + - Host IP: 10.32.8.21 - portnames: - - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 5. Server5 of Type-1: - - testbedname: testbed2. - - hostname: t2-sut2. - - CIMC IP: 10.30.50.22 - - Host IP: 10.30.51.22 + - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. + - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. + - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE. + - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- SUT [Server-Type-C2]: + - testbedname: testbed29. + - hostname: s37-t29-sut1. + - IPMI IP: 10.30.55.22 + - Host IP: 10.32.8.22 - portnames: - - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 6. Server6 of Type-2: - - testbedname: testbed2. - - hostname: t2-tg1. - - CIMC IP: 10.30.50.20 - - Host IP: 10.30.51.20 + - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE. + - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE. + - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-C3]: + - testbedname: testbed29. + - hostname: s38-t29-tg1. + - IPMI IP: 10.30.55.23 + - Host IP: 10.32.8.23 - portnames: - - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. - 7. Server7 of Type-1: - - testbedname: testbed3. - - hostname: t3-sut1. - - CIMC IP: 10.30.50.25 - - Host IP: 10.30.51.25 + - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE. + - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +``` + +#### 2-Node-Zen2 Servers (2n-zn2) PROD + +``` +- SUT [Server-Type-D1]: + - testbedname: testbed210. + - hostname: s60-t210-sut1. + - IPMI IP: 10.30.55.24 + - Host IP: 10.32.8.24 - portnames: - - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 8. Server8 of Type-1: - - testbedname: testbed3. - - hostname: t3-sut2. - - CIMC IP: 10.30.50.26 - - Host IP: 10.30.51.26 + - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE. + - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE. + - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE. + - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE. + - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE. + - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-D2]: + - testbedname: testbed210. + - hostname: s61-t210-tg1. + - IPMI IP: 10.30.55.25 + - Host IP: 10.32.8.25 - portnames: - - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE. - - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE. - - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE. - - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE. - - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 9. Server9 of Type-2: - - testbedname: testbed3. - - hostname: t3-tg1. - - CIMC IP: 10.30.50.24 - - Host IP: 10.30.51.24 + - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE. + - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE. + - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE. +``` + +#### 2-Node-ThunderX2 Servers (2x-tx2) PROD + +Note: Server19 (TG) is shared between testbed33 & testbed211 + +``` +- SUT [Server-Type-E22]: + - testbedname: testbed211. + - hostname: s27-t211-sut1. + - IPMI IP: 10.30.50.69 + - Host IP: 10.30.51.69 + - portnames: + - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE. + - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE. +- TG [Server-Type-E31]: + - testbedname: testbed33 and testbed211. + - hostname: s19-t33t211-tg1. + - IPMI IP: 10.30.50.46 + - Host IP: 10.30.51.49 - portnames: - - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE. - - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE. - - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. - - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. + - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. ``` -#### 3-Node-Skylake (3n-skx) PROD +#### 2-Node-Icelake Servers (2n-icx) PROD ``` -- ServerB11 [Type-B1]: +- SUT [Server-Type-F1]: + - testbedname: testbed212. + - hostname: s71-t212-sut1. + - IPMI IP: 10.30.51.81 + - Host IP: 10.30.50.81 + - portnames: + - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed212. + - hostname: s72-t212-tg1. + - IPMI IP: 10.30.51.82 + - Host IP: 10.30.50.82 + - portnames: + - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- SUT [Server-Type-F1]: + - testbedname: testbed213. + - hostname: s83-t213-sut1. + - IPMI IP: 10.30.51.83 + - Host IP: 10.30.50.83 + - portnames: + - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed213. + - hostname: s84-t213-tg1. + - IPMI IP: 10.30.51.84 + - Host IP: 10.30.50.84 + - portnames: + - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- SUT [Server-Type-F1]: + - testbedname: testbed214. + - hostname: s85-t214-sut1. + - IPMI IP: 10.30.51.85 + - Host IP: 10.30.50.85 + - portnames: + - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed214. + - hostname: s86-t214-tg1. + - IPMI IP: 10.30.51.86 + - Host IP: 10.30.50.86 + - portnames: + - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- SUT [Server-Type-F1]: + - testbedname: testbed215. + - hostname: s87-t215-sut1. + - IPMI IP: 10.30.51.87 + - Host IP: 10.30.50.87 + - portnames: + - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- TG [Server-Type-F2]: + - testbedname: testbed215. + - hostname: s88-t215-tg1. + - IPMI IP: 10.30.51.88 + - Host IP: 10.30.50.88 + - portnames: + - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +``` + +#### 3-Node-Skylake Servers (3n-skx) PROD + +``` +- ServerB11 [Server-Type-B1]: - testbedname: testbed31. - hostname: s11-t31-sut1. - IPMI IP: 10.30.50.43 @@ -917,9 +1542,7 @@ To be completed. - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB12 [Type-B1]: +- ServerB12 [Server-Type-B1]: - testbedname: testbed31. - hostname: s12-t31-sut2. - IPMI IP: 10.30.50.44 @@ -931,9 +1554,7 @@ To be completed. - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE. - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB13 [Type-B2]: +- ServerB13 [Server-Type-B2]: - testbedname: testbed31. - hostname: s13-t31-tg1. - IPMI IP: 10.30.50.45 @@ -945,9 +1566,11 @@ To be completed. - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB14 [Type-B1]: + - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE. +- ServerB14 [Server-Type-B1]: - testbedname: testbed32. - hostname: s14-t32-sut1. - IPMI IP: 10.30.50.55 @@ -959,9 +1582,7 @@ To be completed. - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB15 [Type-B1]: +- ServerB15 [Server-Type-B1]: - testbedname: testbed32. - hostname: s15-t32-sut2. - IPMI IP: 10.30.50.56 @@ -973,9 +1594,7 @@ To be completed. - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE. - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB16 [Type-B2]: +- ServerB16 [Server-Type-B2]: - testbedname: testbed32. - hostname: s16-t32-tg1. - IPMI IP: 10.30.50.57 @@ -987,18 +1606,18 @@ To be completed. - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. + - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE. ``` -Note: ServerB19 (TG) is shared between testbed33 & testbed34 - -#### 3-Node-Rangeley (3n-rng) VERIFY +#### 3-Node-Rangeley Servers (3n-rng) VERIFY Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. ``` -- ServerB22 [Type-B5]: +- ServerB22 [Server-Type-B5]: - testbedname: testbed35. - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1). - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0 @@ -1007,7 +1626,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s22-t35-sut1-p1 - 10GE-port1 ix0 82599. - s22-t35-sut1-p2 - 10GE-port2 ix1 82599. - 1GB ports (tbd) -- ServerB23 [Type-B5]: +- ServerB23 [Server-Type-B5]: - testbedname: testbed35. - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2). - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1 @@ -1016,7 +1635,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s23-t35-sut1-p1 - 10GE-port1 ix0 82599. - s23-t35-sut1-p2 - 10GE-port2 ix1 82599. - 1GB ports (tbd) -- ServerB24 [Type-B5]: +- ServerB24 [Server-Type-B5]: - testbedname: testbed35. - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3). - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2 @@ -1027,10 +1646,12 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - 1GB ports (tbd) ``` -#### 3-Node-Taishan (3n-tsh) WIP +#### 3-Node-Taishan Servers (3n-tsh) PROD + +Note: Server19 (TG) is shared between testbed33 & testbed211 ``` -- ServerB17 [Type-B3]: +- SUT [Server-Type-E21]: - testbedname: testbed33. - hostname: s17-t33-sut1. - IPMI IP: 10.30.50.36 @@ -1040,7 +1661,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE. - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE. - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE. -- ServerB18 [Type-B3]: +- SUT [Server-Type-E21]: - testbedname: testbed33. - hostname: s18-t33-sut2. - IPMI IP: 10.30.50.37 @@ -1050,49 +1671,209 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE. - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE. - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE. -- ServerB19 [Type-B2]: - - testbednames: testbed33 and testbed34. - - hostname: s19-t33t34-tg1. +- TG [Server-Type-E31]: + - testbedname: testbed33 and testbed211. + - hostname: s19-t33t211-tg1. - IPMI IP: 10.30.50.46 - Host IP: 10.30.51.49 - portnames: - - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE. - - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE. -- ServerB20 [Type-B4]: + - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE. +``` + +#### 3-Node-Altra Servers (3n-alt) PROD + +``` +- SUT [Server-Type-E23]: - testbedname: testbed34. - - hostname: s20-t34-sut1. - - IPMI IP: N/A - - Host IP: 10.30.51.41 + - hostname: s62-t34-sut1. + - IPMI IP: 10.30.50.72 + - Host IP: 10.30.51.72 - portnames: - - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell. - - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell. -- ServerB21 [Type-B4]: + - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. +- SUT [Server-Type-E23]: - testbedname: testbed34. - - hostname: s21-t34-sut2. - - IPMI IP: N/A - - Host IP: 10.30.51.42 + - hostname: s63-t34-sut2. + - IPMI IP: 10.30.50.73 + - Host IP: 10.30.51.73 - portnames: - - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell. - - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell. + - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE. +- TG [Server-Type-F4]: + - testbedname: testbed34. + - hostname: s64-t34-tg1. + - IPMI IP: 10.30.50.74 + - Host IP: 10.30.51.74 + - portnames: + - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE. + - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE. + - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE. ``` -#### 3-Node-Mcbin (3n-mcb) TODO +#### 3-Node-Denverton Servers (3n-dnv) PROD ``` -To be completed. +- ServerB30 [Server-Type-B10]: + - testbednames: testbed35. + - hostname: s30-t35-sut1. + - IPMI IP: 10.30.55.12 + - Host IP: 10.32.8.12 + - portnames: + - s30-t35-sut1-p1 - 10GE-port1 x553 copper port. + - s30-t35-sut1-p2 - 10GE-port2 x553 copper port. + - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port. + - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port. +- ServerB31 [Server-Type-B10]: + - testbednames: testbed35. + - hostname: s31-t35-sut2. + - IPMI IP: 10.30.55.13 + - Host IP: 10.32.8.13 + - portnames: + - s31-t35-sut2-p1 - 10GE-port1 x553 copper port. + - s31-t35-sut2-p2 - 10GE-port2 x553 copper port. + - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port. + - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port. +``` + +#### 3-Node-Icelake Servers (3n-icx) PROD + +``` +- ServerF1 [Server-Type-F1]: + - testbedname: testbed37. + - hostname: s65-t37-sut1. + - IPMI IP: 10.30.50.75 + - Host IP: 10.30.51.75 + - portnames: + - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF1 [Server-Type-F1]: + - testbedname: testbed37. + - hostname: s66-t37-sut2. + - IPMI IP: 10.30.50.76 + - Host IP: 10.30.51.76 + - portnames: + - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF3 [Server-Type-F3]: + - testbedname: testbed37. + - hostname: s67-t37-tg1. + - IPMI IP: 10.30.50.77 + - Host IP: 10.30.51.77 + - portnames: + - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF1 [Server-Type-F1]: + - testbedname: testbed38. + - hostname: s78-t38-sut1. + - IPMI IP: 10.30.50.78 + - Host IP: 10.30.51.78 + - portnames: + - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF1 [Server-Type-F1]: + - testbedname: testbed38. + - hostname: s79-t38-sut2. + - IPMI IP: 10.30.50.79 + - Host IP: 10.30.51.79 + - portnames: + - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +- ServerF3 [Server-Type-F3]: + - testbedname: testbed38. + - hostname: s80-t38-tg1. + - IPMI IP: 10.30.50.80 + - Host IP: 10.30.51.80 + - portnames: + - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE. + - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE. + - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE. + - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. + - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. + - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. +``` + +#### 3-Node-SnowRidge Servers (3n-snr) PROD + +``` +- ServerG1 [Server-Type-G1]: + - testbedname: testbed39. + - hostname: s93-t39-sut1. + - IPMI IP: 10.30.50.93 + - Host IP: 10.30.51.93 + - portnames: + - s93-t39-sut1-c1/p1 - 100GE-port1 e810-DA2-2p100GE. + - s93-t39-sut1-c1/p2 - 100GE-port2 e810-DA2-2p100GE. +- ServerG1 [Server-Type-G1]: + - testbedname: testbed39. + - hostname: s94-t39-sut2. + - IPMI IP: 10.30.50.94 + - Host IP: 10.30.51.94 + - portnames: + - s94-t39-sut2-c1/p1 - 100GE-port1 e810-DA2-2p100GE. + - s94-t39-sut2-c1/p2 - 100GE-port1 e810-DA2-2p100GE. +- ServerF4 [Server-Type-F4]: + - testbedname: testbed39. + - hostname: s89-t39t310-tg1. + - IPMI IP: 10.30.50.89 + - Host IP: 10.30.51.89 + - portnames: + - s89-t39t310-tg1-c6/p1 - 100GE-port1 e810-DA2-2p100GE. + - s89-t39t310-tg1-c6/p2 - 100GE-port1 e810-DA2-2p100GE. ``` ### Per Testbed Wiring -#### 1-Node-Skylake (1n-skx) PROD +#### 1-Node-Skylake Wiring (1n-skx) PROD ``` - testbed11: @@ -1103,7 +1884,11 @@ To be completed. - ring3 10GE-ports x710-4p10GE: - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3. - ring4 10GE-ports x710-4p10GE: - - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3. + - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4. + - ring5 100GE-ports e810-2p100GE: + - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1. + - ring6 100GE-ports e810-2p100GE: + - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2. - testbed12: - ring1 10GE-ports x710-4p10GE: - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1. @@ -1112,22 +1897,38 @@ To be completed. - ring3 10GE-ports x710-4p10GE: - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. - ring4 10GE-ports x710-4p10GE: - - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. + - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4. + - ring5 100GE-ports e810-2p100GE: + - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1. + - ring6 100GE-ports e810-2p100GE: + - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2. ``` -#### 1-Node-Thunderx2 (1n-tx2) WIP +#### 1-Node-ThunderX2 Wiring (1n-tx2) PROD ``` - testbed13: - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1. + - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1. - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1. - - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs: - - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1. + - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2. + - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1. + - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2. + +- testbed14: + - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs: + - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1. + - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs: + - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2. + - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1. + - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs: + - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2. ``` -#### 2-Node-Skylake (2n-skx) PROD +#### 2-Node-Skylake Wiring (2n-skx) PROD ``` - testbed21: @@ -1140,10 +1941,7 @@ To be completed. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1. - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1. - - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2. - - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2. - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4. - testbed22: @@ -1156,10 +1954,7 @@ To be completed. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1. - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1. - - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2. - - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2. - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4. - testbed23: @@ -1172,10 +1967,7 @@ To be completed. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1. - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1. - - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2. - - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2. - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4. - testbed24: @@ -1188,21 +1980,24 @@ To be completed. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1. - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1. - - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2. - - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2. - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4. ``` -#### 2-Node-Denverton (2n-dnv) TODO +#### 2-Node-Denverton Wiring (2n-dnv) PROD ``` -To be completed. +- testbed26: + - ring1 10GE-ports x553 copper port on SUT: + - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1. + - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2. + - ring2 10GE-ports x553 fiber port on SUT: + - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3. + - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4. ``` -#### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY +#### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY ``` - testbed25: @@ -1216,83 +2011,158 @@ To be completed. - t25-tg1-p4 to t25-sut1-c2/p4. ``` -#### 3-Node-Haswell (3n-hsw) PROD - -``` - 1. testbed1: - - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs - - t1-tg1-c1/p1 to t1-sut1-c1/p2. - - t1-sut1-c1/p1 to t1-sut2-c1/p2. - - t1-sut2-c1/p1 to t1-tg1-c1/p2. - - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs - - t1-tg1-c2/p1 to t1-sut1-c2/p2. - - t1-sut1-c2/p1 to t1-sut2-c2/p2. - - t1-sut2-c2/p1 to t1-tg1-c2/p2. - - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs - - t1-tg1-c4/p1 to t1-sut1-c4/p2. - - t1-sut1-c4/p1 to t1-sut2-c4/p2. - - t1-sut2-c4/p1 to t1-tg1-c4/p2. - - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs - - t1-tg1-c5/p1 to t1-sut1-c5/p2. - - t1-sut1-c5/p1 to t1-sut2-c5/p2. - - t1-sut2-c5/p1 to t1-tg1-c5/p2. - - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs - - t1-tg1-c2/p1 to t1-sut1-cm/p2. - - t1-sut1-cm/p1 to t1-sut2-cm/p2. - - t1-sut2-cm/p1 to t1-tg1-c2/p2. - - TG loopback ports Intel NIC x710 2p10GE - - t1-tg1-c6/p1 to t1-tg1-c6/p2. - - 2. testbed2: - - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs - - t2-tg1-c1/p1 to t2-sut1-c1/p2. - - t2-sut1-c1/p1 to t2-sut2-c1/p2. - - t2-sut2-c1/p1 to t2-tg1-c1/p2. - - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs - - t2-tg1-c2/p1 to t2-sut1-c2/p2. - - t2-sut1-c2/p1 to t2-sut2-c2/p2. - - t2-sut2-c2/p1 to t2-tg1-c2/p2. - - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs - - t2-tg1-c4/p1 to t2-sut1-c4/p2. - - t2-sut1-c4/p1 to t2-sut2-c4/p2. - - t2-sut2-c4/p1 to t2-tg1-c4/p2. - - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs - - t2-tg1-c5/p1 to t2-sut1-c5/p2. - - t2-sut1-c5/p1 to t2-sut2-c5/p2. - - t2-sut2-c5/p1 to t2-tg1-c5/p2. - - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs - - t2-tg1-c2/p1 to t2-sut1-cm/p2. - - t2-sut1-cm/p1 to t2-sut2-cm/p2. - - t2-sut2-cm/p1 to t2-tg1-c2/p2. - - TG loopback ports Intel NIC x710 2p10GE - - t2-tg1-c6/p1 to t2-tg1-c6/p2. - - 3. testbed3: - - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs - - t3-tg1-c1/p1 to t3-sut1-c1/p2. - - t3-sut1-c1/p1 to t3-sut2-c1/p2. - - t3-sut2-c1/p1 to t3-tg1-c1/p2. - - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs - - t3-tg1-c2/p1 to t3-sut1-c2/p2. - - t3-sut1-c2/p1 to t3-sut2-c2/p2. - - t3-sut2-c2/p1 to t3-tg1-c2/p2. - - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs - - t3-tg1-c4/p1 to t3-sut1-c4/p2. - - t3-sut1-c4/p1 to t3-sut2-c4/p2. - - t3-sut2-c4/p1 to t3-tg1-c4/p2. - - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs - - t3-tg1-c5/p1 to t3-sut1-c5/p2. - - t3-sut1-c5/p1 to t3-sut2-c5/p2. - - t3-sut2-c5/p1 to t3-tg1-c5/p2. - - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs - - t3-tg1-c2/p1 to t3-sut1-cm/p2. - - t3-sut1-cm/p1 to t3-sut2-cm/p2. - - t3-sut2-cm/p1 to t3-tg1-c2/p2. - - TG loopback ports Intel NIC x710 2p10GE - - t3-tg1-c6/p1 to t3-tg1-c6/p2. -``` - -#### 3-Node-Skylake (3n-skx) PROD +#### 2-Node-Cascadelake Wiring (2n-clx) PROD + +``` +- testbed27: + - ring1 10GE-ports x710-4p10GE on SUT: + - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1. + - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3. + - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1. + - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1. + - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2. + - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: + - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1. + - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2. + - ring6 100GE-ports e810-2p100GE on TG: + - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2. + - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1. +- testbed28: + - ring1 10GE-ports x710-4p10GE on SUT: + - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1. + - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3. + - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1. + - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1. + - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2. + - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: + - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1. + - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2. + - ring6 100GE-ports e810-2p100GE on TG: + - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2. + - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1. +- testbed29: + - ring1 10GE-ports x710-4p10GE on SUT: + - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1. + - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3. + - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1. + - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1. + - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2. + - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG: + - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1. + - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2. +``` + +#### 2-Node-Zen2 Wiring (2n-zn2) PROD + +``` +- testbed210: + - ring1 10GE-ports x710-4p10GE on SUT: + - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1. + - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3. + - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1. + - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1. + - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2. +``` + +#### 2-Node-ThunderX2 Wiring (2n-tx2) PROD + +``` +- testbed211: + - ring1 10GE-ports x520-2p10GE on SUTs: + - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1. + - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2. +``` + +#### 2-Node-Icelake Wiring (2n-icx) PROD + +``` +- testbed212: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1. + - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1. + - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2. + - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3. + - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1. + - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2. + - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1. +- testbed213: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1. + - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1. + - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2. + - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3. + - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1. + - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2. + - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1. +- testbed214: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1. + - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1. + - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2. + - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3. + - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1. + - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2. + - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1. +- testbed215: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1. + - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1. + - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2. + - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3. + - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1. + - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2. + - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2. + - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1. +``` + +#### 3-Node-Skylake Wiring (3n-skx) PROD ``` - testbed31: @@ -1337,34 +2207,95 @@ To be completed. - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4. ``` -#### 3-Node-Rangeley (3n-rng) TODO +#### 3-Node-Rangeley Wiring (3n-rng) VERIFY ``` To be completed. ``` -#### 3-Node-Taishan (3n-tsh) WIP +#### 3-Node-Taishan Wiring (3n-tsh) PROD ``` - testbed33: - ring1 10GE-ports x520-2p10GE on SUTs: - - t33t34-tg1-c2/p2 - t33-sut1-c6/p2. - - t33-sut1-c6/p1 - t33-sut2-c6/p2. - - t33-sut2-c6/p1 - t33t34-tg1-c2/p1. + - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2. + - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2. + - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1. - ring2 25GE-ports cx4-2p25GE on SUTs: - - t33t34-tg1-c4/p2 - t33-sut1-c4/p2. - - t33-sut1-c4/p1 - t33-sut2-c4/p2. - - t33-sut2-c4/p1 - t33t34-tg1-c4/p1. + - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2. + - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2. + - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1. ``` -#### 3-Node-Mcbin (3n-mcb) WIP +#### 3-Node-Altra Wiring (3n-alt) PROD ``` - testbed34: - - ring1 10GE-ports Marvell on SUTs: - - t33t34-tg1-c2/p3 - t34-sut1-ca/p1. - - t34-sut1-ca/p2 - t34-sut2-ca/p1. - - t34-sut2-ca/p2 - t33t34-tg1-c2/p4. + - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs: + - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2. + - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2. + - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2. +``` + +#### 3-Node-Denverton Wiring (3n-dnv) PROD + +``` +- testbed35: + - ring1 10GE-ports x553 copper port on SUTs: + - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2. + - s30-t35-sut1-p1 to s31-t35-sut2-p1. + - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2. + - ring2 10GE-ports x553 fiber port on SUTs: + - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4. + - s30-t35-sut1-p3 to s31-t35-sut2-p3. + - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4. +``` + +#### 3-Node-Icelake Wiring (3n-icx) PROD + +``` +- testbed37: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: + - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1. + - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2. + - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: + - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1. + - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2. + - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2. + - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3. + - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4. + - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT + - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1. + - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2. + - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2. +- testbed38: + - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: + - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1. + - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2. + - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2. + - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: + - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1. + - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2. + - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2. + - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3. + - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4. + - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4. + - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT + - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1. + - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2. + - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2. +``` + +#### 3-Node-SnowRidge Wiring (3n-snr) PROD + +``` +- testbed39: + - ring1 100GE-ports e810-DA2-2p100GE on SUTs and TG: + - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1. + - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2. + - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2. ``` ## Inventory @@ -1384,25 +2315,39 @@ To be completed. - Operating System: Native IxOS. ``` -### Arm Servers +### Arm Servers ``` 1. Arm Cortex A-72 servers - - 1 * ThunderX2 - - Chassis: Marvell ThunderX2 - - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2. + - 2 * ThunderX2 (VPP Device) + - Chassis: GIGABYTE Rack Mount + - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2 + - RAM Memory: 16* 16GB DIMM + - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480 + - 1 * ThunderX2 (Performance) + - Chassis: GIGABYTE Rack Mount + - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2. - RAM Memory: 4* 32GB RDIMM - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 - 2 * Huawei TaiShan 2280. - Chassis: Huawei TaiShan 2280. - - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72. + - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72. - RAM Memory: 8* 16GB DDR4-2400MT/s. - Disks: 1* 4TB SATA HDD. - - 3 * MACCHIATObin - - Chassis: MACCHIATObin. - - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72. - - RAM Memory: 1* 16GB DDR4. - - Disks: 1* 128GB(?) SATA SDD. +2. Arm Neoverse N1 servers + - 2 * Ampere Altra (Performance) + - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U + - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1 + - RAM Memory: 16* 8GB DDR4-3200MT/s + - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983 + - 2 * Ampere Altra (Build) + - Chassis: Gigabyte R152-P30-00 1U + - Motherboard: MP32-AR1-00 + - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1) + - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1 + - RAM Memory: 12* 16GB DDR4-3200MT/s + - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983 ``` ### Xeon and Atom Servers @@ -1412,7 +2357,7 @@ To be completed. - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors. - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. 2. Intel Atom servers with Rangely processors.