X-Git-Url: https://gerrit.fd.io/r/gitweb?p=csit.git;a=blobdiff_plain;f=docs%2Freport%2Fintroduction%2Ftest_scenarios_overview.rst;fp=docs%2Freport%2Fintroduction%2Ftest_scenarios_overview.rst;h=8d66836e9d8366c82444c41260095b244b07d94e;hp=ee334a6407c1f9e50d6be32095c1e2b9e7679596;hb=ce1c52b1fd27d3e2b6c4909219fa98418565ba61;hpb=d6c832b02ac7d3073dd8651b089a72ec8240b183 diff --git a/docs/report/introduction/test_scenarios_overview.rst b/docs/report/introduction/test_scenarios_overview.rst index ee334a6407..8d66836e9d 100644 --- a/docs/report/introduction/test_scenarios_overview.rst +++ b/docs/report/introduction/test_scenarios_overview.rst @@ -12,18 +12,17 @@ Brief overview of test scenarios covered in this report: #. **VPP Performance**: VPP performance tests are executed in physical FD.io testbeds, focusing on VPP network data plane performance in NIC-to-NIC switching topologies. Tested across Intel Xeon Haswell - and Skylake servers, range of NICs (10GE, 25GE, 40GE) and multi- - thread/multi-core configurations. VPP application runs in bare-metal + and Skylake servers, ARM, Denverton, range of NICs (10GE, 25GE, 40GE) and + multi-thread/multi-core configurations. VPP application runs in bare-metal host user-mode handling NICs. TRex is used as a traffic generator. #. **VPP Vhostuser Performance with KVM VMs**: VPP VM service switching performance tests using vhostuser virtual interface for - interconnecting multiple Testpmd-in-VM instances. VPP vswitch + interconnecting multiple NF-in-VM instances. VPP vswitch instance runs in bare-metal user-mode handling NICs and connecting - over vhost-user interfaces to VM instances each running DPDK - Testpmd with virtio virtual interfaces. Similarly to VPP - Performance, tests are run across a range of configurations. TRex - is used as a traffic generator. + over vhost-user interfaces to VM instances each running VPP with virtio + virtual interfaces. Similarly to VPP Performance, tests are run across a + range of configurations. TRex is used as a traffic generator. #. **VPP Memif Performance with LXC and Docker Containers**: VPP Container service switching performance tests using memif virtual @@ -49,12 +48,11 @@ Brief overview of test scenarios covered in this report: cover vNIC-to-vNIC vNIC-to-nestedVM-to-vNIC forwarding topologies. Scapy is used as a traffic generator. -#. **Honeycomb Functional**: Honeycomb functional tests are executed in - virtual FD.io testbeds, focusing on Honeycomb management and - programming functionality of VPP. Tests cover a range of CRUD - operations executed against VPP. - .. + #. **Honeycomb Functional**: Honeycomb functional tests are executed in + virtual FD.io testbeds, focusing on Honeycomb management and + programming functionality of VPP. Tests cover a range of CRUD + operations executed against VPP. #. **DMM Functional**: DMM functional tests are executed in virtual FD.io testbeds demonstrating a single server (DUT1) and single client (DUT2) scenario using DMM framework and Linux kernel TCP/IP