X-Git-Url: https://gerrit.fd.io/r/gitweb?p=csit.git;a=blobdiff_plain;f=docs%2Freport%2Fvpp_performance_tests%2Fcsit_release_notes.rst;h=725b40bee29daf39af6f78ccf351a590556e8274;hp=a4077c13a587aa66a04b6fc0ba0d24137362421d;hb=785519e26196b9e0a5016d0fc54ed099fd0a920f;hpb=d166ae0881c29dfd05ed61b9a12156f17981bb6d diff --git a/docs/report/vpp_performance_tests/csit_release_notes.rst b/docs/report/vpp_performance_tests/csit_release_notes.rst index a4077c13a5..725b40bee2 100644 --- a/docs/report/vpp_performance_tests/csit_release_notes.rst +++ b/docs/report/vpp_performance_tests/csit_release_notes.rst @@ -13,7 +13,8 @@ Changes in CSIT |release| #. VPP performance test framework changes - - Added VAT command history collection for every test case as part of teardown. + - Added VAT command history collection for every test case as part of + teardown. #. Added VPP performance tests @@ -25,14 +26,16 @@ Changes in CSIT |release| - **vhost-user tests with one VM** - - L2 Bridge Domain switched-forwarding with Intel x710 NIC, Intel x520 NIC, - Intel xl710 NIC. + - L2 Bridge Domain switched-forwarding with Intel x710 NIC, Intel x520 + NIC, Intel xl710 NIC. - VXLAN and L2 Bridge Domain switched-forwarding with Intel x520 NIC. - **vhost-user tests with two VMs service chain** - - L2 cross-connect switched-forwarding with Intel x520 NIC, Intel xl710 NIC. - - L2 Bridge Domain switched-forwarding with Intel x520 NIC, Intel xl710 NIC. + - L2 cross-connect switched-forwarding with Intel x520 NIC, Intel xl710 + NIC. + - L2 Bridge Domain switched-forwarding with Intel x520 NIC, Intel xl710 + NIC. - IPv4 routed-forwarding with Intel x520 NIC, Intel xl710 NIC. - **IPSec encryption with** @@ -211,22 +214,17 @@ Here is the list of known issues in CSIT |release| for VPP performance tests: | | for ip4scale200k, ip4scale2m scale IPv4 routed- | | Observed frequency: all test runs. | | | forwarding tests. ip4scale20k tests are fine. | | | +---+-------------------------------------------------+------------+-----------------------------------------------------------------+ -| 2 | Sporadic VAT API timeouts during ip6scale2m | VPP-712 | Needs fixing VPP VAT API timeouts for large volume of IPv6 | -| | scale IPv6 routed-forwarding tests when volume | | routes. | -| | adding IPv6 routes - 2M in this case. | | | -| | ip6scale200k works. | | | -+---+-------------------------------------------------+------------+-----------------------------------------------------------------+ -| 3 | Vic1385 and Vic1227 low performance. | VPP-664 | Low NDR performance. | +| 2 | Vic1385 and Vic1227 low performance. | VPP-664 | Low NDR performance. | | | | | | +---+-------------------------------------------------+------------+-----------------------------------------------------------------+ -| 4 | Sporadic NDR discovery test failures on x520. | CSIT-750 | Suspected issue with HW settings (BIOS, FW) in LF | +| 3 | Sporadic NDR discovery test failures on x520. | CSIT-750 | Suspected issue with HW settings (BIOS, FW) in LF | | | | | infrastructure. Issue can't be replicated outside LF. | +---+-------------------------------------------------+------------+-----------------------------------------------------------------+ -| 5 | VPP in 2t2c setups - large variation | CSIT-568 | Suspected NIC firmware or DPDK driver issue affecting NDR | +| 4 | VPP in 2t2c setups - large variation | CSIT-568 | Suspected NIC firmware or DPDK driver issue affecting NDR | | | of discovered NDR throughput values across | | throughput. Applies to XL710 and X710 NICs, x520 NICs are fine. | | | multiple test runs with xl710 and x710 NICs. | | | +---+-------------------------------------------------+------------+-----------------------------------------------------------------+ -| 6 | Lower than expected NDR and PDR throughput with | CSIT-569 | Suspected NIC firmware or DPDK driver issue affecting NDR and | +| 5 | Lower than expected NDR and PDR throughput with | CSIT-569 | Suspected NIC firmware or DPDK driver issue affecting NDR and | | | xl710 and x710 NICs, compared to x520 NICs. | | PDR throughput. Applies to XL710 and X710 NICs. | +---+-------------------------------------------------+------------+-----------------------------------------------------------------+