X-Git-Url: https://gerrit.fd.io/r/gitweb?p=csit.git;a=blobdiff_plain;f=docs%2Freport%2Fvpp_performance_tests%2Fcsit_release_notes.rst;h=7a8bf9bf5bbc2f8bf440f1511a4d946f12b099b5;hp=8f9586a8a0fc62dfee0fa6747b880c897a07f4ef;hb=f99ce0d330567ef331f6622559e4561485378f5f;hpb=30271f9f5149d789535afdd5cfd42f30eac360c9 diff --git a/docs/report/vpp_performance_tests/csit_release_notes.rst b/docs/report/vpp_performance_tests/csit_release_notes.rst index 8f9586a8a0..7a8bf9bf5b 100644 --- a/docs/report/vpp_performance_tests/csit_release_notes.rst +++ b/docs/report/vpp_performance_tests/csit_release_notes.rst @@ -6,32 +6,36 @@ Changes in |csit-release| #. VPP PERFORMANCE TESTS - - **Service density 2n-skx tests**: Network Function Virtualization (NFV) - service density tests focus on measuring total per server throughput at - varied NFV service *packing* densities with vswitch providing host - dataplane. The goal is to compare and contrast performance of a shared - vswitch for different network topologies and virtualization technologies, - and their impact on vswitch performance and efficiency in a range of NFV - service configurations. - - - **Experimental Soak Tests**: Added performamce soak tests framework + - **Service density 2n-skx tests**: Added higher NF density tests with two + NFs' data-plane threads sharing a physical core. VPP IPv4 routing is now + used as a VNF payload similar to CNF tests. + + - **Soak Tests**: Optimized performamce soak tests framework code for extended time duration tests and throughput discovery at given PLR and at give total test time e.g. minutes, hours, - days, weeks, months, years. See updated + days, weeks. See updated :ref:`test_methodology` section for more details. #. TEST FRAMEWORK - - **Container code optimizations**: Optimized container library allows to - run containre_memif tests faster. + - **Qemu code refactor**: Complete code refactor of the key components of + QemuUtil.py and QemuManager.py (L1 and L2 KW counterparts). Added + implementation of kernel-image-kvm based VM replacing the previously used + NestedVM images. Added ability to run VPP as a payload in VNF. - - **CSIT PAPI Support**: Continue converting existing VAT L1 keywords to - PAPI L1 KWs in CSIT using VPP Python bindings. Required for migrating away - from VAT. + - **CSIT PAPI Support**: Continued conversion of CSIT VAT L1 keywords to + PAPI L1 KWs in CSIT using VPP Python bindings. Redesign of key components + of PAPI Executor and PAPI history. - **General Code Housekeeping**: Ongoing RF keywords optimizations, removal of redundant RF keywords. + - **Test suite generator**: Added capability to generate suites for + different NIC models as well as throughput search algorithm types. Uses + base tests suites as source. + + - **TOX verification**: Added verifications for test suite generator. + #. PRESENTATION AND ANALYTICS LAYER - **Graphs Layout Improvements**: Improved performance graphs layout @@ -41,8 +45,8 @@ Changes in |csit-release| .. #. MISCELLANEOUS - - **3n-dnv Tests (3rd Party)**: Published performance tests for 3n- - dnv (3-Node Atom Denverton) from 3rd party testbeds running FD.io + - **2n-dnv Tests (3rd Party)**: Published performance tests for 2n- + dnv (2-Node Atom Denverton) from 3rd party testbeds running FD.io |csit-release| automated testing code. Only graphs for Packet Throughput and Speedup Multi-core and not for Packet Latency were published as there are no results for Packet @@ -59,24 +63,24 @@ Known Issues List of known issues in |csit-release| for VPP performance tests: -+----+-----------------------------------------+---------------------------------------------------------------------------------------------------------------------------------+ -| # | JiraID | Issue Description | -+====+=========================================+=================================================================================================================================+ -| 1 | `CSIT-570 | Sporadic (1 in 200) NDR discovery test failures on x520. DPDK reporting rx-errors, indicating L1 issue. | -| | `_ | Suspected issue with HW combination of X710-X520 in LF testbeds. Not observed outside of LF testbeds. | -+----+-----------------------------------------+---------------------------------------------------------------------------------------------------------------------------------+ -| 2 | `VPP-1562 | Link bonding (mode LACP, transmit policy l34) test are failing due to VPP crashing producing core dump. | -| | `_ | | -+----+-----------------------------------------+---------------------------------------------------------------------------------------------------------------------------------+ -| 3 | `CSIT-1427 | Scale HW IPsec are failing due to issue with selecting ipsec backend in VPP. | -| | `_ | | -+----+-----------------------------------------+---------------------------------------------------------------------------------------------------------------------------------+ -| 4 | `VPP-1563 | AVF L2patch tests are failing for all packet size and core combination. Reason: null-node blackholed packets in show error. | -| | `_ | | -+----+-----------------------------------------+---------------------------------------------------------------------------------------------------------------------------------+ -| 5 | `CSIT-1234 | VPP IPSecHW/IPSecsW scale interface mode, low NDR and PDR 64B throughput in 3n-hsw testbeds, in CSIT-19.01 vs. CSIT-18.10. | -| | `_ | | -+----+-----------------------------------------+---------------------------------------------------------------------------------------------------------------------------------+ -| 6 | `CSIT-1428 | VM vhost tests with RXQ more than 2 are failing on 3n-skx. Suspecting RXQ configuration issues. | -| | `_ | | -+----+-----------------------------------------+---------------------------------------------------------------------------------------------------------------------------------+ ++----+-----------------------------------------+----------------------------------------------------------------------------------------------------------+ +| # | JiraID | Issue Description | ++====+=========================================+==========================================================================================================+ +| 1 | `CSIT-570 | Sporadic (1 in 200) NDR discovery test failures on x520. DPDK reporting rx-errors, indicating L1 issue. | +| | `_ | Suspected issue with HW combination of X710-X520 in LF testbeds. Not observed outside of LF testbeds. | ++----+-----------------------------------------+----------------------------------------------------------------------------------------------------------+ +| 2 | `CSIT-1503 | [`TRex-519 `_] XL710/XXV710 with FW 6.0.1 will have | +| | `_ | Rx drop rate of 27MPPS. | ++----+-----------------------------------------+----------------------------------------------------------------------------------------------------------+ +| 3 | `CSIT-1501 | Sporadic crypto backend fails loading `VPP-1670 `_ | +| | `_ | | ++----+-----------------------------------------+----------------------------------------------------------------------------------------------------------+ +| 4 | `CSIT-1427 | Sporadic HW aes-128-cbc-sha1 tunnel-interface tests are failing. | +| | `_ | `VPP-1671 `_ | ++----+-----------------------------------------+----------------------------------------------------------------------------------------------------------+ +| 5 | `CSIT-1498 | Memif tests are sporadically failing on initialization of memif connection. | +| | `_ | | ++----+-----------------------------------------+----------------------------------------------------------------------------------------------------------+ +| 6 | `CSIT-1499 | AVF tests are sporadically failing on initialization of AVF interface. | +| | `_ | | ++----+-----------------------------------------+----------------------------------------------------------------------------------------------------------+