X-Git-Url: https://gerrit.fd.io/r/gitweb?p=csit.git;a=blobdiff_plain;f=docs%2Freport%2Fvpp_performance_tests%2Fcsit_release_notes.rst;h=b4fc9de3c93aa4da1512ca6b6e3e1a9bfbbc76cc;hp=10e01ababa75005677db7d7fb6e132af95017be1;hb=f6c04897464c868c034237729bfe738a95d43b25;hpb=36595cd3fcea206f6f9024cde0645d6f605a09c6;ds=inline diff --git a/docs/report/vpp_performance_tests/csit_release_notes.rst b/docs/report/vpp_performance_tests/csit_release_notes.rst index 10e01ababa..b4fc9de3c9 100644 --- a/docs/report/vpp_performance_tests/csit_release_notes.rst +++ b/docs/report/vpp_performance_tests/csit_release_notes.rst @@ -6,31 +6,36 @@ Changes in CSIT |release| #. VPP performance test environment changes - - Further VM and vhost-user test environment optimizations - Qemu virtio + - Further optimizations of VM and vhost-user test environment - Qemu virtio queue size increased from default value of 256 to 1024. - - Addition of HW cryptodev devices in all three LF FD.io physical testbeds. + - Addition of HW cryptodev devices - Intel QAT 8950 50G - in all three + LF FD.io physical testbeds. -#. Added tests +#. VPP performance test framework changes - - CGNAT + - Added VAT command history collection for every test case as part of teardown. + +#. Added VPP performance tests + + - **CGNAT** - Carrier Grade Network Address Translation tests with varying number of users and ports per user: 1u-15p, 10u-15p, 100u-15p, 1000u-15p, 2000u-15p, 4000u-15p - with Intel x520 NIC. - - vhost-user tests with one VM + - **vhost-user tests with one VM** - L2 Bridge Domain switched-forwarding with Intel x710 NIC, Intel x520 NIC, Intel xl710 NIC. - VXLAN and L2 Bridge Domain switched-forwarding with Intel x520 NIC. - - vhost-user tests with two VM service chain + - **vhost-user tests with two VMs service chain** - L2 cross-connect switched-forwarding with Intel x520 NIC, Intel xl710 NIC. - L2 Bridge Domain switched-forwarding with Intel x520 NIC, Intel xl710 NIC. - IPv4 routed-forwarding with Intel x520 NIC, Intel xl710 NIC. - - IPSec encryption with + - **IPSec encryption with** - AES-GCM, CBC-SHA1 ciphers, in combination with IPv4 routed-forwarding with Intel xl710 NIC. @@ -205,22 +210,21 @@ Here is the list of known issues in CSIT |release| for VPP performance tests: | | for ip4scale200k, ip4scale2m scale IPv4 routed- | | Observed frequency: all test runs. | | | forwarding tests. ip4scale20k tests are fine. | | | +---+-------------------------------------------------+------------+-----------------------------------------------------------------+ -| 2 | VAT API timeouts during ip6scale2m scale IPv6 | | Needs fixing VPP VAT API timeouts for large volume of IPv6 | -| | routed-forwarding tests when volume adding IPv6 | VPP-? | routes. | +| 2 | VAT API timeouts during ip6scale2m scale IPv6 | VPP-712 | Needs fixing VPP VAT API timeouts for large volume of IPv6 | +| | routed-forwarding tests when volume adding IPv6 | | routes. | | | routes - 2M in this case. ip6scale2kk works. | | | +---+-------------------------------------------------+------------+-----------------------------------------------------------------+ -| 3 | Vic1385 and Vic1227 low performance | CSIT-? | Low NDR performance. | -| | | | . | +| 3 | Vic1385 and Vic1227 low performance | VPP-664 | Low NDR performance. | +| | | | | +---+-------------------------------------------------+------------+-----------------------------------------------------------------+ -| 4 | Sporadic NDR discovery test failures on x520 | CSIT-? | Suspected issue with HW settings (BIOS, FW) in LF | +| 4 | Sporadic NDR discovery test failures on x520 | CSIT-750 | Suspected issue with HW settings (BIOS, FW) in LF | | | | | infrastructure. Issue can't be replicated outside LF. | +---+-------------------------------------------------+------------+-----------------------------------------------------------------+ -| 5 | Testpmd - Non-repeatible zig-zagging NDR | CSIT-? | Suspected NIC firmware or driver issue affecting NDR | -| | throughput in multi-thread/-core tests | | in multi-thread/-core operation. Need to update to latest | -| | - 2t2c - for some tested NICs. | | firmware in NICs. Applies to XL710 and X710 NICs. | +| 5 | VPP in 2t2c setups - large variation | CSIT-568 | Suspected NIC firmware or DPDK driver issue affecting NDR | +| | of discovered NDR throughput values across | | throughput. Applies to XL710 and X710 NICs, x520 NICs are fine. | +| | multiple test runs with xl710 and x710 NICs. | | | +---+-------------------------------------------------+------------+-----------------------------------------------------------------+ -| 6 | VPP - Non-repeatible zig-zagging NDR | CSIT-? | Suspected NIC firmware or driver issue affecting NDR | -| | throughput in multi-thread/-core tests | | in multi-thread/-core operation. Need to update to latest | -| | - 2t2c - for some tested NICs. | | firmware in NICs. Applies to XL710 and X710 NICs. | +| 6 | Lower than expected NDR and PDR throughput with | CSIT-569 | Suspected NIC firmware or DPDK driver issue affecting NDR and | +| | xl710 and x710 NICs, compared to x520 NICs. | | PDR throughput. Applies to XL710 and X710 NICs. | +---+-------------------------------------------------+------------+-----------------------------------------------------------------+