X-Git-Url: https://gerrit.fd.io/r/gitweb?p=csit.git;a=blobdiff_plain;f=docs%2Freport%2Fvpp_performance_tests%2Foverview.rst;h=bd0681dc40d15a1a133209a5655b78ab2282ed76;hp=e9c4b8d14894b506c21f341304ecd3a745ec72ba;hb=ce1088d88744f2c040801c9852565d522b3feb68;hpb=064f852eeab1b0341c374586a847729c6980ffbc diff --git a/docs/report/vpp_performance_tests/overview.rst b/docs/report/vpp_performance_tests/overview.rst index e9c4b8d148..bd0681dc40 100644 --- a/docs/report/vpp_performance_tests/overview.rst +++ b/docs/report/vpp_performance_tests/overview.rst @@ -2,17 +2,17 @@ Overview ======== For description of physical testbeds used for VPP performance tests -please refer to :ref:`physical_testbeds`. +please refer to :ref:`tested_physical_topologies`. + +.. _tested_logical_topologies: Logical Topologies ------------------ -.. _tested_logical_topologies: - CSIT VPP performance tests are executed on physical testbeds described -in :ref:`physical_testbeds`. Based on the packet path thru server SUTs, -three distinct logical topology types are used for VPP DUT data plane -testing: +in :ref:`tested_physical_topologies`. Based on the packet path thru +server SUTs, three distinct logical topology types are used for VPP DUT +data plane testing: #. NIC-to-NIC switching topologies. #. VM service switching topologies. @@ -87,7 +87,7 @@ VM Service Switching VM service switching topology test cases require VPP DUT to communicate with Virtual Machines (VMs) over vhost-user virtual interfaces. -Two types of VM service topologies are tested in CSIT |release|: +Two types of VM service topologies are tested in |csit-release|: #. "Parallel" topology with packets flowing within SUT from NIC(s) via VPP DUT to VM, back to VPP DUT, then out thru NIC(s). @@ -161,7 +161,7 @@ Container Service Switching Container service switching topology test cases require VPP DUT to communicate with Containers (Ctrs) over memif virtual interfaces. -Three types of VM service topologies are tested in CSIT |release|: +Three types of VM service topologies are tested in |csit-release|: #. "Parallel" topology with packets flowing within SUT from NIC(s) via VPP DUT to Container, back to VPP DUT, then out thru NIC(s). @@ -259,7 +259,7 @@ topologies and configurations: regardless of packet loss. Maximum load for specified Ethernet frame size is set to the bi-directional link rate. -CSIT |release| includes following performance test areas covered across +|csit-release| includes following performance test areas covered across a range of NIC drivers and NIC models: +-----------------------+----------------------------------------------+ @@ -349,8 +349,8 @@ NIC models has been limited to few baseline tests. Performance Tests Naming ------------------------ -FD.io CSIT |release| follows a common structured naming convention for -all performance and system functional tests, introduced in CSIT rls1701. +FD.io |csit-release| follows a common structured naming convention for +all performance and system functional tests, introduced in CSIT-17.01. The naming should be intuitive for majority of the tests. Complete description of FD.io CSIT test naming convention is provided on