X-Git-Url: https://gerrit.fd.io/r/gitweb?p=csit.git;a=blobdiff_plain;f=tests%2Fperf%2F40ge2p1xl710-eth-l2xcbase-eth-4vhost-2vm-ndrpdrdisc.robot;h=60bb066b684c8983d03afe81865e84b719e4cb65;hp=b0bd5550361a834a4600ab4f19f896f185ad8558;hb=430afafb4cadf503ccee99c09f6de7402f5404c7;hpb=7436d8bdf60bca9b80fb76781e1f709bbcd435da diff --git a/tests/perf/40ge2p1xl710-eth-l2xcbase-eth-4vhost-2vm-ndrpdrdisc.robot b/tests/perf/40ge2p1xl710-eth-l2xcbase-eth-4vhost-2vm-ndrpdrdisc.robot index b0bd555036..60bb066b68 100644 --- a/tests/perf/40ge2p1xl710-eth-l2xcbase-eth-4vhost-2vm-ndrpdrdisc.robot +++ b/tests/perf/40ge2p1xl710-eth-l2xcbase-eth-4vhost-2vm-ndrpdrdisc.robot @@ -18,12 +18,12 @@ | Force Tags | 3_NODE_SINGLE_LINK_TOPO | PERFTEST | HW_ENV | NDRPDRDISC | ... | NIC_Intel-XL710 | ETH | L2XCFWD | BASE | VHOST | VM | ... -| Suite Setup | 3-node Performance Suite Setup with DUT's NIC model +| Suite Setup | Set up 3-node performance topology with DUT's NIC model | ... | L2 | Intel-XL710 -| Suite Teardown | 3-node Performance Suite Teardown +| Suite Teardown | Tear down 3-node performance topology | ... -| Test Setup | Performance test setup -| Test Teardown | Performance test with vhost and VM with dpdk-testpmd teardown +| Test Setup | Set up performance test +| Test Teardown | Tear down performance test with vhost and VM with dpdk-testpmd | ... | ${min_rate}pps | ${framesize} | ${traffic_profile} | ... | dut1_node=${dut1} | dut1_vm_refs=${dut1_vm_refs} | ... | dut2_node=${dut2} | dut2_vm_refs=${dut2_vm_refs} @@ -86,12 +86,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find NDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -114,12 +114,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find PDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -143,12 +143,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find NDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -171,12 +171,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find PDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -201,12 +201,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find NDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -230,12 +230,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '1' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '1' worker threads and '1' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find PDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -259,12 +259,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find NDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -287,12 +287,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find PDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -316,12 +316,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find NDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -344,12 +344,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find PDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -374,12 +374,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find NDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -403,12 +403,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '2' worker threads and rxqueues '1' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '2' worker threads and '1' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find PDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -432,12 +432,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find NDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -460,12 +460,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find PDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -489,12 +489,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find NDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -517,12 +517,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find PDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -547,12 +547,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find NDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold} @@ -576,12 +576,12 @@ | | ${dut2_vm_refs}= | Create Dictionary | | Set Test Variable | ${dut1_vm_refs} | | Set Test Variable | ${dut2_vm_refs} -| | Given Add '4' worker threads and rxqueues '2' in 3-node single-link topo -| | And Add PCI devices to DUTs from 3-node single link topology -| | And Add No Multi Seg to all DUTs +| | Given Add '4' worker threads and '2' rxqueues in 3-node single-link circular topology +| | And Add PCI devices to DUTs in 3-node single link topology +| | And Add no multi seg to all DUTs | | And Apply startup configuration on all VPP DUTs -| | When L2 xconnect with Vhost-User for '2' initialized in a 3-node circular topology -| | And '2' Guest VMs with dpdk-testpmd connected via vhost-user is setup in a 3-node circular topology +| | When Initialize L2 xconnect with Vhost-User for '2' in 3-node circular topology +| | And Configure '2' guest VMs with dpdk-testpmd connected via vhost-user in 3-node circular topology | | Then Find PDR using binary search and pps | | ... | ${framesize} | ${binary_min} | ${binary_max} | ${traffic_profile} | | ... | ${min_rate} | ${max_rate} | ${threshold}