Trending: Add 2vm tests 26/12326/2
authorTibor Frank <tifrank@cisco.com>
Wed, 2 May 2018 12:14:27 +0000 (14:14 +0200)
committerTibor Frank <tifrank@cisco.com>
Wed, 2 May 2018 12:15:32 +0000 (12:15 +0000)
Change-Id: Ifc008ba50c4c84e781c12dc3080d3a361090efb6
Signed-off-by: Tibor Frank <tifrank@cisco.com>
resources/tools/presentation/generator_tables.py
resources/tools/presentation/specification_CPTA.yaml

index 9264dcd..120d39b 100644 (file)
@@ -745,6 +745,8 @@ def table_performance_trending_dashboard(table, input_data):
     for job, builds in table["data"].items():
         for build in builds:
             for tst_name, tst_data in data[job][str(build)].iteritems():
+                if tst_name in table["ignore-list"]:
+                    continue
                 if tbl_dict.get(tst_name, None) is None:
                     name = "{0}-{1}".format(tst_data["parent"].split("-")[0],
                                             "-".join(tst_data["name"].
index 268b356..7b6d6fc 100644 (file)
   - "name"
   - "parent"
   - "result"
+  ignore-list:
+  - "tests.vpp.perf.l2.10ge2p1x520-eth-l2bdscale1mmaclrn-mrr.tc01-64B-1t1c-eth-l2bdscale1mmaclrn-ndrdisc"
   outlier-const: 1.5
   window: 14
   evaluated-window: 14
   - "name"
   - "parent"
   - "result"
+  ignore-list:
+  - "tests.vpp.perf.l2.10ge2p1x520-eth-l2bdscale1mmaclrn-mrr.tc05-64B-2t2c-eth-l2bdscale1mmaclrn-ndrdisc"
   outlier-const: 1.5
   window: 14
   evaluated-window: 14
   - "name"
   - "parent"
   - "result"
+  ignore-list:
+  - "tests.vpp.perf.l2.10ge2p1x520-eth-l2bdscale1mmaclrn-mrr.tc09-64B-4t4c-eth-l2bdscale1mmaclrn-ndrdisc"
   outlier-const: 1.5
   window: 14
   evaluated-window: 14
     - title: "VPP 1T1C VM vhost eth 64B Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-eth-1t1c-x520"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-X520-DA2' and '64B' and 'MRR' and '1T1C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-X520-DA2' and '64B' and 'MRR' and '1T1C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
 
       parameters:
       - "result"
     - title: "VPP 2T2C VM vhost eth 64B Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-eth-2t2c-x520"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-X520-DA2' and '64B' and 'MRR' and '2T2C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-X520-DA2' and '64B' and 'MRR' and '2T2C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
       parameters:
       - "result"
       periods:
     - title: "VPP 4T4C VM vhost eth 64B Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-eth-4t4c-x520"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-X520-DA2' and '64B' and 'MRR' and '4T4C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-X520-DA2' and '64B' and 'MRR' and '4T4C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
       parameters:
       - "result"
       periods:
     - title: "VPP 1T1C VM vhost eth IMIX Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-imix-eth-1t1c-x520"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-X520-DA2' and 'IMIX' and 'MRR' and '1T1C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-X520-DA2' and 'IMIX' and 'MRR' and '1T1C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
 
       parameters:
       - "result"
     - title: "VPP 2T2C VM vhost eth IMIX Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-imix-eth-2t2c-x520"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-X520-DA2' and 'IMIX' and 'MRR' and '2T2C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-X520-DA2' and 'IMIX' and 'MRR' and '2T2C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
       parameters:
       - "result"
       periods:
     - title: "VPP 4T4C VM vhost eth IMIX Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-imix-eth-4t4c-x520"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-X520-DA2' and 'IMIX' and 'MRR' and '4T4C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-X520-DA2' and 'IMIX' and 'MRR' and '4T4C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
       parameters:
       - "result"
       periods:
     - title: "VPP 1T1C VM vhost eth 64B Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-eth-1t1c-xl710"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-XL710' and '64B' and 'MRR' and '1T1C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-XL710' and '64B' and 'MRR' and '1T1C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
 
       parameters:
       - "result"
     - title: "VPP 2T2C VM vhost eth 64B Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-eth-2t2c-xl710"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-XL710' and '64B' and 'MRR' and '2T2C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-XL710' and '64B' and 'MRR' and '2T2C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
       parameters:
       - "result"
       periods:
     - title: "VPP 4T4C VM vhost eth 64B Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-eth-4t4c-xl710"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-XL710' and '64B' and 'MRR' and '4T4C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-XL710' and '64B' and 'MRR' and '4T4C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
       parameters:
       - "result"
       periods:
     - title: "VPP 1T1C VM vhost eth IMIX Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-imix-eth-1t1c-xl710"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-XL710' and 'IMIX' and 'MRR' and '1T1C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-XL710' and 'IMIX' and 'MRR' and '1T1C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
 
       parameters:
       - "result"
     - title: "VPP 2T2C VM vhost eth IMIX Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-imix-eth-2t2c-xl710"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-XL710' and 'IMIX' and 'MRR' and '2T2C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-XL710' and 'IMIX' and 'MRR' and '2T2C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
       parameters:
       - "result"
       periods:
     - title: "VPP 4T4C VM vhost eth IMIX Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-imix-eth-4t4c-xl710"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-XL710' and 'IMIX' and 'MRR' and '4T4C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-XL710' and 'IMIX' and 'MRR' and '4T4C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
       parameters:
       - "result"
       periods:
     - title: "VPP 1T1C VM vhost eth 64B Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-eth-1t1c-x710"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-X710' and '64B' and 'MRR' and '1T1C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-X710' and '64B' and 'MRR' and '1T1C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
 
       parameters:
       - "result"
     - title: "VPP 2T2C VM vhost eth 64B Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-eth-2t2c-x710"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-X710' and '64B' and 'MRR' and '2T2C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-X710' and '64B' and 'MRR' and '2T2C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
       parameters:
       - "result"
       periods:
     - title: "VPP 4T4C VM vhost eth 64B Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-eth-4t4c-x710"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-X710' and '64B' and 'MRR' and '4T4C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-X710' and '64B' and 'MRR' and '4T4C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
       parameters:
       - "result"
       periods:
     - title: "VPP 1T1C VM vhost eth IMIX Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-imix-eth-1t1c-x710"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-X710' and 'IMIX' and 'MRR' and '1T1C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-X710' and 'IMIX' and 'MRR' and '1T1C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
 
       parameters:
       - "result"
     - title: "VPP 2T2C VM vhost eth IMIX Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-imix-eth-2t2c-x710"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-X710' and 'IMIX' and 'MRR' and '2T2C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-X710' and 'IMIX' and 'MRR' and '2T2C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
       parameters:
       - "result"
       periods:
     - title: "VPP 4T4C VM vhost eth IMIX Packet Throughput - {period} Trending"
       output-file-name: "vm-vhost-imix-eth-4t4c-x710"
       data: "plot-performance-trending"
-      filter: "'NIC_Intel-X710' and 'IMIX' and 'MRR' and '4T4C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD' and not 'DOT1Q' and not '2VM'"
+      filter: "'NIC_Intel-X710' and 'IMIX' and 'MRR' and '4T4C' and 'VHOST' and not 'VXLAN' and not 'IP4FWD'"
       parameters:
       - "result"
       periods: