doc: add fdio dc vexxhost server inventory across all locations 62/30662/14
authorMaciek Konstantynowicz <mkonstan@cisco.com>
Thu, 7 Jan 2021 19:51:56 +0000 (19:51 +0000)
committerMaciek Konstantynowicz <mkonstan@cisco.com>
Mon, 29 Mar 2021 13:50:26 +0000 (13:50 +0000)
Change-Id: I17ffb5912964bd0c2da59ad4843dfb411f9c3e0c
Signed-off-by: Maciek Konstantynowicz <mkonstan@cisco.com>
docs/lab/fdio-dc-inventory-vexxhost.md [new file with mode: 0644]

diff --git a/docs/lab/fdio-dc-inventory-vexxhost.md b/docs/lab/fdio-dc-inventory-vexxhost.md
new file mode 100644 (file)
index 0000000..0756967
--- /dev/null
@@ -0,0 +1,267 @@
+<!-- MarkdownTOC autolink="true" -->
+
+- [FD.io DC Move Logistics](#fdio-dc-move-logistics)
+  - [DC Naming Change](#dc-naming-change)
+  - [Network Connectivity](#network-connectivity)
+  - [DC Move Sequence](#dc-move-sequence)
+    - [Timeline](#timeline)
+    - [Stage-1 MTL2 1 rack - Preferred](#stage-1-mtl2-1-rack)
+    - [Stage-2 MTL1 4 racks](#stage-2-mtl1-4-racks)
+- [FD.io DC Vexxhost Inventory](#fdio-dc-vexxhost-inventory)
+  - [Missing Equipment Inventory](#missing-equipment-inventory)
+  - [MTL2 Inventory 1 rack](#mtl2-inventory-1-rack)
+    - [Rack "R1" 16 servers - FDIO-DONE VH-OPEN](#rack-r1-16-servers---fdio-done-vh-open)
+  - [MTL1 Inventory 4 racks](#mtl1-inventory-4-racks)
+    - [Rack B316 11 servers - FDIO-DONE VH-OPEN](#rack-b316-11-servers---fdio-done-vh-open)
+    - [Rack B425 10 servers - FDIO-DONE VH-OPEN](#rack-b425-10-servers---fdio-done-vh-open)
+    - [Rack B612 12 servers - FDIO-DONE VH-OPEN](#rack-b612-12-servers---fdio-done-vh-open)
+    - [Rack B611 15 servers - FDIO-DONE VH-OPEN](#rack-b611-15-servers---fdio-done-vh-open)
+
+<!-- /MarkdownTOC -->
+
+## FD.io DC Move Logistics
+
+### DC Naming Change
+
+FYI Inventory of the two DCs in Montreal hosted by Vexxhost on behalf of LFN.
+
+MTL2 = (old name) YUL2
+MTL1 = (old name) YUL1
+
+Inventory info provided in the context of moving both MTL1 and MTL2 DCs and
+consolidating into a single DC location, named YUL1.
+
+### Network Connectivity
+
+- L2VPN connectivity between sites.
+- VLANs are extended using VXLAN, with VXLAN packets carried over Wireguard.
+- No change to IPv4 numbering scheme or addresses required.
+
+### DC Move Sequence
+
+#### Timeline
+
+- Stage-1, done
+- Stage-2, wk?
+- ...
+- Stage-n, wk?
+
+#### Stage-1 MTL2 1 rack - VH-DONE, FDIO_DONE
+
+Rest of 1 rack with 10 servers split into the following testbeds and servers:
+
+- 3 x 2n-clx
+- 1 x 2n-dnv
+- 1 x 2n-zn2
+- 1 x 3n-dnv
+- 4 x Nomad client
+
+#### Stage-2 MTL1
+
+name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4
+s41-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FQ,b612,u29-u30,10.30.51.28,10.30.50.28,r?,u?,10.30.51.28,10.30.50.28
+s40-nomad,up,nomad-cluster1,nomad-server,UCSC-C240-M4SX,FCH2013V0HZ,b612,u27-u28,10.30.51.30,10.30.50.30,r?,u?,10.30.51.30,10.30.50.30
+s39-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH2013V0J2,b612,u25-u26,10.30.51.29,10.30.50.29,r?,u?,10.30.51.29,10.30.50.29
+s2-t12-sut1,up,t12,1n-skx,SYS-7049GP-TRT,C7470KH06A20119,b425,u33-u36,10.30.51.51,10.30.50.48,r?,u?,10.30.51.51,10.30.50.48
+s56-t37-sut1,up,t37,2n-tx2,ThunderX2-9980,N/A,b611,u16-u17,10.30.51.71,10.30.50.71,r?,u?,10.30.51.71,10.30.50.71
+s53-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,b612,u17,10.30.51.39,10.30.50.39,r?,u?,10.30.51.39,10.30.50.39
+s54-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,b612,u16,10.30.51.40,10.30.50.40,r?,u?,10.30.51.40,10.30.50.40
+
+#### Stage-3 MTL1
+
+name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4
+s42-nomad,up,nomad-cluster1,nomad-server,UCSC-C240-M3S,FCH1719V18Y,b611,u23-u24,10.30.51.32,10.30.50.32,r?,u?,10.30.51.32,10.30.50.32
+s44-nomad,up,nomad-cluster1,nomad-client,UCSC-C220-M4S,FCH2139V129,b612,u20,10.30.51.34,10.30.50.34,r?,u?,10.30.51.34,10.30.50.34
+s45-nomad,up,nomad-cluster1,nomad-client,UCSC-C220-M4S,FCH2139V166,b612,u19,10.30.51.35,10.30.50.35,r?,u?,10.30.51.35,10.30.50.35
+s1-t11-sut1,up,t11,1n-skx,SYS-7049GP-TRT,C7470KH06A20154,b425,u37-u40,10.30.51.50,10.30.50.47,r?,u?,10.30.51.50,10.30.50.47
+s55-t36-sut1,up,t36,1n-tx2,ThunderX2-9980,N/A,b316,u10-u11,10.30.51.70,10.30.50.70,r?,u?,10.30.51.70,10.30.50.70
+s52-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,b611,u19-u20,10.30.51.65,10.30.50.65,r?,u?,10.30.51.65,10.30.50.65
+s51-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,b611,u19-u20,10.30.51.66,10.30.50.66,r?,u?,10.30.51.66,10.30.50.66
+
+#### Stage-4 MTL1
+
+name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4
+s43-nomad,up,nomad-cluster1,nomad-server,UCSC-C220-M3L,FCH1726V1M4,b611,u22,10.30.51.33,10.30.50.33,r?,u?,10.30.51.33,10.30.50.33
+s49-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,b611,u19-u20,10.30.51.67,10.30.50.67,r?,u?,10.30.51.67,10.30.50.67
+s50-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,b611,u19-u20,10.30.51.68,10.30.50.68,r?,u?,10.30.51.68,10.30.50.68
+t1-tg1,up,t1,3n-hsw,UCSC-C240-M4SX,FCH1950V1HM,b611,u35-u36,10.30.51.16,10.30.50.16,r?,u?,10.30.51.16,10.30.50.16
+t1-sut1,up,t1,3n-hsw,UCSC-C240-M4SX,FCH1950V1KH,b611,u33-u34,10.30.51.17,10.30.50.17,r?,u?,10.30.51.17,10.30.50.17
+t1-sut2,up,t1,3n-hsw,UCSC-C240-M4SX,FCH1950V1FP,b611,u31-u32,10.30.51.18,10.30.50.18,r?,u?,10.30.51.18,10.30.50.18
+t2-tg1,up,t2,3n-hsw,UCSC-C240-M4SX,FCH1950V1KG,b611,u29-u30,10.30.51.20,10.30.50.20,r?,u?,10.30.51.20,10.30.50.20
+t2-sut1,up,t2,3n-hsw,UCSC-C240-M4SX,FCH1950V1FM,b611,u27-u28,10.30.51.21,10.30.50.21,r?,u?,10.30.51.21,10.30.50.21
+t2-sut2,up,t2,3n-hsw,UCSC-C240-M4SX,FCH1950V1FN,b611,u25-u26,10.30.51.22,10.30.50.22,r?,u?,10.30.51.22,10.30.50.22
+
+#### Stage-5 MTL1
+
+name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4
+t3-tg1,up,t3,3n-hsw,UCSC-C240-M4SX,FCH1950V1H5,b612,u35-u36,10.30.51.24,10.30.50.24,r?,u?,10.30.51.24,10.30.50.24
+t3-sut1,up,t3,3n-hsw,UCSC-C240-M4SX,FCH1950V1FS,b612,u33-u34,10.30.51.25,10.30.50.25,r?,u?,10.30.51.25,10.30.50.25
+t3-sut2,up,t3,3n-hsw,UCSC-C240-M4SX,FCH1950V1FL,b612,u31-u32,10.30.51.26,10.30.50.26,r?,u?,10.30.51.26,10.30.50.26
+fdio-marvell-dev,up,N/A,dev,ThunderX-88XX,N/A,b612,u18,10.30.51.38,10.30.50.38,r?,u?,10.30.51.38,10.30.50.38
+
+#### Stage-6 MTL1
+
+name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4
+s3-t21-sut1,up,t21,2n-skx,SYS-7049GP-TRT,C7470KH06A20167,b425,u29-u32,10.30.51.44,10.30.50.41,r?,u?,10.30.51.44,10.30.50.41
+s4-t21-tg1,up,t21,2n-skx,SYS-7049GP-TRT,C7470KH06A20158,b425,u25-u28,10.30.51.45,10.30.50.42,r?,u?,10.30.51.45,10.30.50.42
+s5-t22-sut1,up,t22,2n-skx,SYS-7049GP-TRT,N/A,b425,u21-u24,10.30.51.52,10.30.50.49,r?,u?,10.30.51.52,10.30.50.49
+s6-t22-tg1,up,t22,2n-skx,SYS-7049GP-TRT,N/A,b425,u17-u20,10.30.51.53,10.30.50.50,r?,u?,10.30.51.53,10.30.50.50
+s7-t23-sut1,up,t23,2n-skx,SYS-7049GP-TRT,N/A,b425,u13-u16,10.30.51.54,10.30.50.51,r?,u?,10.30.51.54,10.30.50.51
+s8-t23-tg1,up,t23,2n-skx,SYS-7049GP-TRT,C7470KH06A20035,b425,u9-u12,10.30.51.55,10.30.50.52,r?,u?,10.30.51.55,10.30.50.52
+s9-t24-sut1,up,t24,2n-skx,SYS-7049GP-TRT,C7470KH06A20055,b425,u5-u8,10.30.51.56,10.30.50.53,r?,u?,10.30.51.56,10.30.50.53
+s10-t24-tg1,up,t24,2n-skx,SYS-7049GP-TRT,C7470KH06A20196,b425,u1-u4,10.30.51.57,10.30.50.54,r?,u?,10.30.51.57,10.30.50.54
+
+
+#### Stage-7 MTL1
+
+name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4
+s11-t31-sut1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20037,b316,u37-u40,10.30.51.46,10.30.50.43,r?,u?,10.30.51.46,10.30.50.43
+s12-t31-sut2,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20018,b316,u33-u36,10.30.51.47,10.30.50.44,r?,u?,10.30.51.47,10.30.50.44
+s13-t31-tg1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20043,b316,u29-u32,10.30.51.48,10.30.50.45,r?,u?,10.30.51.48,10.30.50.45
+s14-t32-sut1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20075,b316,u25-u28,10.30.51.58,10.30.50.55,r?,u?,10.30.51.58,10.30.50.55
+s15-t32-sut2,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20010,b316,u21-u24,10.30.51.59,10.30.50.56,r?,u?,10.30.51.59,10.30.50.56
+s16-t32-tg1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20047,b316,u17-u20,10.30.51.60,10.30.50.57,r?,u?,10.30.51.60,10.30.50.57
+s19-t33t34-tg1,up,t33t34,3n-tsh/2n-tx2,SYS-7049GP-TRT,C7470KH06A20056,b316,u13-u16,10.30.51.49,10.30.50.46,r?,u?,10.30.51.49,10.30.50.46
+s27-t34-sut1,up,t34,2n-tx2,ThunderX2-9975,K61186073100003,b316,u12,10.30.51.69,10.30.50.69,r?,u?,10.30.51.69,10.30.50.69
+s18-t33-sut2,up,t33,3n-tsh,HUAWEI-TAISHAN-2280,N/A,b316,u8-u9,10.30.51.37,10.30.50.37,r?,u?,10.30.51.37,10.30.50.37
+s17-t33-sut1,up,t33,3n-tsh,HUAWEI-TAISHAN-2280,N/A,b316,u6-u7,10.30.51.36,10.30.50.36,r?,u?,10.30.51.36,10.30.50.36
+
+
+## FD.io DC Vexxhost Inventory
+
+- for each DC location, per rack .csv table with server inventory
+- captured inventory data: name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4
+  - name: CSIT functional server name as tracked in [CSIT testbed specification](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md), followed by "/" and the actual configured hostname, unless it is the same as CSIT name.
+  - oper-status: operational status (up|down|ipmi).
+  - testbed-id: CSIT testbed identifier.
+  - role: 2n/3n-xxx performance testbed, nomad-client, nomad-server.
+    - role exceptions: decommission, repurpose, spare.
+  - model: server model.
+  - s/n: serial number.
+  - rackid: current location rack id.
+  - rackunit: current location rack unit id.
+  - mgmt-ip4: current management IPv4 address on management VLAN.
+  - ipmi-ip4: current IPMI IPv4 address on LOM VLAN.
+  - new-rackid: new location rack id.
+  - new-rackunit: new location rack unit id.
+  - new-mgmt-ip4: new management IPv4 address on management VLAN.
+  - new-ipmi-ip4: new IPMI IPv4 address on LOM VLAN.
+
+### Missing Equipment Inventory
+
+1. Ixia PerfectStorm One Appliance
+   - [Specification: Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n554)
+   - [Wiring: 2-Node-IxiaPS1L47 Servers (2n-ps1)](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n1017)
+   - [mgmt-ip4 10.30.51.62 s26-t25-tg1](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n374)
+   - [ipmi-ip4 10.30.50.59 s26-t25-tg1](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n281)
+2. Skylake Xeon SUT for TCP/IP host stack tests
+   - [Specification: Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n573)
+   - [Wiring: 2-Node-IxiaPS1L47 Servers (2n-ps1)](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n1017)
+   - [mgmt-ip4 10.30.51.61 s25-t25-sut1](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n373)
+   - [ipmi-ip4 10.30.50.58 s25-t25-sut1](https://git.fd.io/csit/tree/docs/lab/testbed_specifications.md#n280)
+
+### MTL2 Inventory 1 rack
+
+#### Rack "r3016.12" 16 servers - FDIO-DONE VH-DONE
+
+name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4
+s61-t210-tg1,up,t210,2n-zn2,AS-1014S-WTRT,C8150LI50NS2689,r1,u40,10.32.8.25,10.30.55.25,r3016.12,u33,10.32.8.25,10.30.55.25
+s60-t210-sut1,up,t210,2n-zn2,AS-1114S-WTRT,N/A,r1,u39,10.32.8.24,10.30.55.24,r3016.12,u32,10.32.8.24,10.30.55.24
+s48-nomad,up,nomad-cluster1,nomad-client,SYS-1029P-WTRT,C1160LI12NM0540,r1,u38,10.32.8.16,10.30.55.16,r3016.12,u31,10.32.8.16,10.30.55.16
+s47-nomad,up,nomad-cluster1,nomad-client,SYS-1029P-WTRT,C1160LI12NM0241,r1,u37,10.32.8.15,10.30.55.15,r3016.12,u30,10.32.8.15,10.30.55.15
+s46-nomad,up,nomad-cluster1,nomad-client,SYS-1029P-WTRT,C1160LI12NM0256,r1,u36,10.32.8.14,10.30.55.14,r3016.12,u29,10.32.8.14,10.30.55.14
+s57-nomad,up,nomad-cluster1,nomad-client,SYS-7049GP-TRT,C7470KH37A30505,r1,u32-u35,10.32.8.17,10.30.55.17,r3016.12,u25-u28,10.32.8.17,10.30.55.17
+s33-t27-sut1,up,t27,2n-clx,SYS-7049GP-TRT,C7470KH37A30567,r1,u28-u31,10.32.8.18,10.30.55.18,r3016.12,u21-u24,10.32.8.18,10.30.55.18
+s34-t27-tg1,up,t27,2n-clx,SYS-7049GP-TRT,C7470KH37A30565,r1,u24-u27,10.32.8.19,10.30.55.19,r3016.12,u17-u20,10.32.8.19,10.30.55.19
+s35-t28-sut1,up,t28,2n-clx,SYS-7049GP-TRT,C7470KH37A30509,r1,u20-u23,10.32.8.20,10.30.55.20,r3016.12,u13-u16,10.32.8.20,10.30.55.20
+s36-t28-tg1,up,t28,2n-clx,SYS-7049GP-TRT,C7470KH37A30511,r1,u16-u19,10.32.8.21,10.30.55.21,r3016.12,u9-u12,10.32.8.21,10.30.55.21
+s37-t29-sut1,up,t29,2n-clx,SYS-7049GP-TRT,C7470KH37A30566,r1,u12-u15,10.32.8.22,10.30.55.22,r3016.12,u5-u8,10.32.8.22,10.30.55.22
+s38-t29-tg1,up,t29,2n-clx,SYS-7049GP-TRT,C7470KH37A30506,r1,u8-u11,10.32.8.23,10.30.55.23,r3016.12,u1-u4,10.32.8.23,10.30.55.23
+s31-t35-sut2/dnv3,up,t35,3n-dnv,SYS-E300-9A,CE300AG39040898,r1,u7,10.32.8.13,10.30.55.13,r3016.12,u40,10.32.8.13,10.30.55.13
+s30-t35-sut1/dnv2,up,t35,3n-dnv,SYS-E300-9A,CE300AG39040866,r1,u6,10.32.8.12,10.30.55.12,r3016.12,u39,10.32.8.12,10.30.55.12
+s29-t26-sut1/dnv1,up,t26,2n-dnv,SYS-E300-9A,CE300AG39040897,r1,u5,10.32.8.11,10.30.55.11,r3016.12,u38,10.32.8.11,10.30.55.11
+s28-t26t35-tg1/super,up,t26t35,2n/3n-dnv,SYS-7049GP-TRT,C7470KH06A20137,r1,u1-u4,10.32.8.10,10.30.55.10,r3016.12,u34-u37,10.32.8.10,10.30.55.10
+
+### MTL1 Inventory 4 racks
+
+#### Rack B316 11 servers - FDIO-DONE VH-OPEN
+
+name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4
+s11-t31-sut1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20037,b316,u37-u40,10.30.51.46,10.30.50.43,r?,u?,10.30.51.46,10.30.50.43
+s12-t31-sut2,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20018,b316,u33-u36,10.30.51.47,10.30.50.44,r?,u?,10.30.51.47,10.30.50.44
+s13-t31-tg1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20043,b316,u29-u32,10.30.51.48,10.30.50.45,r?,u?,10.30.51.48,10.30.50.45
+s14-t32-sut1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20075,b316,u25-u28,10.30.51.58,10.30.50.55,r?,u?,10.30.51.58,10.30.50.55
+s15-t32-sut2,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20010,b316,u21-u24,10.30.51.59,10.30.50.56,r?,u?,10.30.51.59,10.30.50.56
+s16-t32-tg1,up,t31,3n-skx,SYS-7049GP-TRT,C7470KH06A20047,b316,u17-u20,10.30.51.60,10.30.50.57,r?,u?,10.30.51.60,10.30.50.57
+s19-t33t34-tg1,up,t33t34,3n-tsh/2n-tx2,SYS-7049GP-TRT,C7470KH06A20056,b316,u13-u16,10.30.51.49,10.30.50.46,r?,u?,10.30.51.49,10.30.50.46
+s27-t34-sut1,up,t34,2n-tx2,ThunderX2-9975,K61186073100003,b316,u12,10.30.51.69,10.30.50.69,r?,u?,10.30.51.69,10.30.50.69
+s55-t36-sut1,up,t36,1n-tx2,ThunderX2-9980,N/A,b316,u10-u11,10.30.51.70,10.30.50.70,r?,u?,10.30.51.70,10.30.50.70
+s18-t33-sut2,up,t33,3n-tsh,HUAWEI-TAISHAN-2280,N/A,b316,u8-u9,10.30.51.37,10.30.50.37,r?,u?,10.30.51.37,10.30.50.37
+s17-t33-sut1,up,t33,3n-tsh,HUAWEI-TAISHAN-2280,N/A,b316,u6-u7,10.30.51.36,10.30.50.36,r?,u?,10.30.51.36,10.30.50.36
+name?,down,testbed?,spare?,SYS-7049GP-TRT,C7470KH06A20022,b316,u2-u5,mgmt?,ipmi?,r?,u?,mgmt?,ipmi?
+
+Todos:
+
+- Rename: s55-t36-sut1 -> s55-t14-sut1  // ubuntu2004 refresh
+
+#### Rack B425 10 servers - FDIO-DONE VH-OPEN
+
+name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4
+s1-t11-sut1,up,t11,1n-skx,SYS-7049GP-TRT,C7470KH06A20154,b425,u37-u40,10.30.51.50,10.30.50.47,r?,u?,10.30.51.50,10.30.50.47
+s2-t12-sut1,up,t12,1n-skx,SYS-7049GP-TRT,C7470KH06A20119,b425,u33-u36,10.30.51.51,10.30.50.48,r?,u?,10.30.51.51,10.30.50.48
+s3-t21-sut1,up,t21,2n-skx,SYS-7049GP-TRT,C7470KH06A20167,b425,u29-u32,10.30.51.44,10.30.50.41,r?,u?,10.30.51.44,10.30.50.41
+s4-t21-tg1,up,t21,2n-skx,SYS-7049GP-TRT,C7470KH06A20158,b425,u25-u28,10.30.51.45,10.30.50.42,r?,u?,10.30.51.45,10.30.50.42
+s5-t22-sut1,up,t22,2n-skx,SYS-7049GP-TRT,N/A,b425,u21-u24,10.30.51.52,10.30.50.49,r?,u?,10.30.51.52,10.30.50.49
+s6-t22-tg1,up,t22,2n-skx,SYS-7049GP-TRT,N/A,b425,u17-u20,10.30.51.53,10.30.50.50,r?,u?,10.30.51.53,10.30.50.50
+s7-t23-sut1,up,t23,2n-skx,SYS-7049GP-TRT,N/A,b425,u13-u16,10.30.51.54,10.30.50.51,r?,u?,10.30.51.54,10.30.50.51
+s8-t23-tg1,up,t23,2n-skx,SYS-7049GP-TRT,C7470KH06A20035,b425,u9-u12,10.30.51.55,10.30.50.52,r?,u?,10.30.51.55,10.30.50.52
+s9-t24-sut1,up,t24,2n-skx,SYS-7049GP-TRT,C7470KH06A20055,b425,u5-u8,10.30.51.56,10.30.50.53,r?,u?,10.30.51.56,10.30.50.53
+s10-t24-tg1,up,t24,2n-skx,SYS-7049GP-TRT,C7470KH06A20196,b425,u1-u4,10.30.51.57,10.30.50.54,r?,u?,10.30.51.57,10.30.50.54
+
+#### Rack B612 12 servers - FDIO-DONE VH-OPEN
+
+name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4
+softiron-1,to-be-removed,t-,decommissioned,model?,sn?,b612,u37,10.30.51.12,ipmi?,r?,u?,mgmt?,ipmi?
+t3-tg1,up,t3,3n-hsw,UCSC-C240-M4SX,FCH1950V1H5,b612,u35-u36,10.30.51.24,10.30.50.24,r?,u?,10.30.51.24,10.30.50.24
+t3-sut1,up,t3,3n-hsw,UCSC-C240-M4SX,FCH1950V1FS,b612,u33-u34,10.30.51.25,10.30.50.25,r?,u?,10.30.51.25,10.30.50.25
+t3-sut2,up,t3,3n-hsw,UCSC-C240-M4SX,FCH1950V1FL,b612,u31-u32,10.30.51.26,10.30.50.26,r?,u?,10.30.51.26,10.30.50.26
+s41-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH1950V1FQ,b612,u29-u30,10.30.51.28,10.30.50.28,r?,u?,10.30.51.28,10.30.50.28
+s40-nomad,up,nomad-cluster1,nomad-server,UCSC-C240-M4SX,FCH2013V0HZ,b612,u27-u28,10.30.51.30,10.30.50.30,r?,u?,10.30.51.30,10.30.50.30
+s39-nomad,up,nomad-cluster1,nomad-client,UCSC-C240-M4SX,FCH2013V0J2,b612,u25-u26,10.30.51.29,10.30.50.29,r?,u?,10.30.51.29,10.30.50.29
+s44-nomad,up,nomad-cluster1,nomad-client,UCSC-C220-M4S,FCH2139V129,b612,u20,10.30.51.34,10.30.50.34,r?,u?,10.30.51.34,10.30.50.34
+s45-nomad,up,nomad-cluster1,nomad-client,UCSC-C220-M4S,FCH2139V166,b612,u19,10.30.51.35,10.30.50.35,r?,u?,10.30.51.35,10.30.50.35
+fdio-marvell-dev,up,N/A,dev,ThunderX-88XX,N/A,b612,u18,10.30.51.38,10.30.50.38,r?,u?,10.30.51.38,10.30.50.38
+s53-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,b612,u17,10.30.51.39,10.30.50.39,r?,u?,10.30.51.39,10.30.50.39
+s54-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,b612,u16,10.30.51.40,10.30.50.40,r?,u?,10.30.51.40,10.30.50.40
+
+Notes:
+
+- softiron-1, decommission request and instructions issued on
+  16-Sep-2020, per Vexxhost ticket [#FDU-009676 - New arm hardware - 2xThunderX2](https://secure.vexxhost.com/billing/viewticket.php?tid=FDU-009676&c=ncHht136),
+  search for "softiron".
+
+#### Rack B611 15 servers - FDIO-DONE VH-OPEN
+
+name,oper-status,testbed-id,role,model,s/n,rackid,rackunit,mgmt-ip4,ipmi-ip4,new-rackid,new-rackunit,new-mgmt-ip4,new-ipmi-ip4
+softiron-2,to-be-removed,t-,decommissioned,model?,sn?,b611,u38,10.30.51.13,ipmi?,r?,u?,mgmt?,ipmi?
+softiron-3,to-be-removed,t-,decommissioned,model?,sn?,b611,u37,10.30.51.14,ipmi?,r?,u?,mgmt?,ipmi?
+t1-tg1,up,t1,3n-hsw,UCSC-C240-M4SX,FCH1950V1HM,b611,u35-u36,10.30.51.16,10.30.50.16,r?,u?,10.30.51.16,10.30.50.16
+t1-sut1,up,t1,3n-hsw,UCSC-C240-M4SX,FCH1950V1KH,b611,u33-u34,10.30.51.17,10.30.50.17,r?,u?,10.30.51.17,10.30.50.17
+t1-sut2,up,t1,3n-hsw,UCSC-C240-M4SX,FCH1950V1FP,b611,u31-u32,10.30.51.18,10.30.50.18,r?,u?,10.30.51.18,10.30.50.18
+t2-tg1,up,t2,3n-hsw,UCSC-C240-M4SX,FCH1950V1KG,b611,u29-u30,10.30.51.20,10.30.50.20,r?,u?,10.30.51.20,10.30.50.20
+t2-sut1,up,t2,3n-hsw,UCSC-C240-M4SX,FCH1950V1FM,b611,u27-u28,10.30.51.21,10.30.50.21,r?,u?,10.30.51.21,10.30.50.21
+t2-sut2,up,t2,3n-hsw,UCSC-C240-M4SX,FCH1950V1FN,b611,u25-u26,10.30.51.22,10.30.50.22,r?,u?,10.30.51.22,10.30.50.22
+s42-nomad,up,nomad-cluster1,nomad-server,UCSC-C240-M3S,FCH1719V18Y,b611,u23-u24,10.30.51.32,10.30.50.32,r?,u?,10.30.51.32,10.30.50.32
+s43-nomad,up,nomad-cluster1,nomad-server,UCSC-C220-M3L,FCH1726V1M4,b611,u22,10.30.51.33,10.30.50.33,r?,u?,10.30.51.33,10.30.50.33
+s52-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,b611,u19-u20,10.30.51.65,10.30.50.65,r?,u?,10.30.51.65,10.30.50.65
+s51-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,b611,u19-u20,10.30.51.66,10.30.50.66,r?,u?,10.30.51.66,10.30.50.66
+s49-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,b611,u19-u20,10.30.51.67,10.30.50.67,r?,u?,10.30.51.67,10.30.50.67
+s50-nomad,up,nomad-cluster1,nomad-client,ThunderX-88XX,N/A,b611,u19-u20,10.30.51.68,10.30.50.68,r?,u?,10.30.51.68,10.30.50.68
+s56-t37-sut1,up,t37,2n-tx2,ThunderX2-9980,N/A,b611,u16-u17,10.30.51.71,10.30.50.71,r?,u?,10.30.51.71,10.30.50.71
+
+Notes:
+
+- softiron-2, softiron-3, decommission request and instructions issued
+  on 16-Sep-2020, per Vexxhost ticket
+  [#FDU-009676 - New arm hardware - 2xThunderX2](https://secure.vexxhost.com/billing/viewticket.php?tid=FDU-009676&c=ncHht136),
+  search for "softiron".
\ No newline at end of file