LF2 testbed topology file 54/954/5
authorMiroslav Miklus <mmiklus@cisco.com>
Mon, 2 May 2016 15:25:46 +0000 (17:25 +0200)
committerMiroslav Miklus <mmiklus@cisco.com>
Sun, 8 May 2016 12:39:08 +0000 (12:39 +0000)
Change-Id: I7c465a057640782219a8eb3b4c131d2d8edfcadc
Signed-off-by: Miroslav Miklus <mmiklus@cisco.com>
topologies/available/lf_testbed2.yaml

index ebce145..5e03d33 100644 (file)
@@ -15,17 +15,89 @@ nodes:
     username: testuser
     password: Cisco1234
     interfaces:
     username: testuser
     password: Cisco1234
     interfaces:
+      port1:
+        # t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:35:76:a8"
+        pci_address: "0000:02:00.0"
+        driver: i40e
+        link: link1
+        model: Intel-XL710
+      port2:
+        # t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:35:76:a9"
+        pci_address: "0000:02:00.1"
+        driver: i40e
+        link: link2
+        model: Intel-XL710
       port3:
       port3:
+        # t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ed:5c"
+        pci_address: "0000:05:00.0"
+        driver: i40e
+        link: link3
+        model: Intel-X710
+      port4:
+        # t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ed:5d"
+        pci_address: "0000:05:00.1"
+        driver: i40e
+        link: link4
+        model: Intel-X710
+      port5:
+        # t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ee:5c"
+        pci_address: "0000:07:00.0"
+        driver: i40e
+        link: link5
+        model: Intel-X710
+      port6:
+        # t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ee:5d"
+        pci_address: "0000:07:00.1"
+        driver: i40e
+        link: link6
+        model: Intel-X710
+      port7:
+        # t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:37:1f:1c"
+        pci_address: "0000:86:00.0"
+        driver: i40e
+        link: link7
+        model: Intel-XL710
+      port8:
+        # t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:37:1f:19"
+        pci_address: "0000:86:00.1"
+        driver: i40e
+        link: link8
+        model: Intel-XL710
+      port9:
+        # t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
         mac_address: "3c:fd:fe:9c:ed:7c"
         pci_address: "0000:88:00.0"
         mac_address: "3c:fd:fe:9c:ed:7c"
         pci_address: "0000:88:00.0"
-        link: link1
         driver: i40e
         driver: i40e
+        link: link9
         model: Intel-X710
         model: Intel-X710
-      port5:
+      port10:
+        # t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         mac_address: "3c:fd:fe:9c:ed:7d"
         pci_address: "0000:88:00.1"
         mac_address: "3c:fd:fe:9c:ed:7d"
         pci_address: "0000:88:00.1"
-        link: link2
         driver: i40e
         driver: i40e
+        link: link10
+        model: Intel-X710
+      port11:
+        # t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ee:58"
+        pci_address: "0000:84:00.0"
+        driver: i40e
+        link: link11
+        model: Intel-X710
+      port12:
+        # t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ee:59"
+        pci_address: "0000:84:00.1"
+        driver: i40e
+        link: link11
         model: Intel-X710
   DUT1:
     type: DUT
         model: Intel-X710
   DUT1:
     type: DUT
@@ -35,15 +107,65 @@ nodes:
     password: Cisco1234
     interfaces:
       port1:
     password: Cisco1234
     interfaces:
       port1:
-        mac_address: "3c:fd:fe:9c:ee:ed"
-        pci_address: "0000:87:00.1"
+        # t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
+        mac_address: "90:e2:ba:b5:02:b8"
+        pci_address: "0000:0a:00.0"
+        link: link12
+        model: Intel-X520-DA2
+      port2:
+        # t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
+        mac_address: "90:e2:ba:b5:02:b9"
+        pci_address: "0000:0a:00.1"
         link: link1
         link: link1
-        model: Intel-X710
+        model: Intel-X520-DA2
       port3:
       port3:
+        # t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
+        mac_address: "04:62:73:8c:ca:cd"
+        pci_address: "0000:13:00.0"
+        link: link13
+        model: Cisco-VIC-1385
+      port4:
+        # t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
+        mac_address: "04:62:73:8c:ca:ce"
+        pci_address: "0000:15:00.0"
+        link: link3
+        model: Cisco-VIC-1385
+      port5:
+        # t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:35:77:08"
+        pci_address: "0000:85:00.0"
+        link: link14
+        model: Intel-XL710
+      port6:
+        # t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:35:77:0d"
+        pci_address: "0000:85:00.1"
+        link: link7
+        model: Intel-XL710
+      port7:
+        # t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
         mac_address: "3c:fd:fe:9c:ee:ec"
         pci_address: "0000:87:00.0"
         mac_address: "3c:fd:fe:9c:ee:ec"
         pci_address: "0000:87:00.0"
-        link: link3
+        link: link15
         model: Intel-X710
         model: Intel-X710
+      port8:
+        # t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
+        mac_address: "3c:fd:fe:9c:ee:ed"
+        pci_address: "0000:87:00.1"
+        link: link9
+        model: Intel-X710
+      port9:
+        # t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
+        mac_address: "00:fe:c8:e4:d0:9b"
+        pci_address: "0000:06:00.0"
+        link: link16
+        model: Cisco-VIC-1227
+      port10:
+        # t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
+        mac_address: "00:fe:c8:e4:d0:9c"
+        pci_address: "0000:07:00.0"
+        link: link3
+        model: Cisco-VIC-1227
   DUT2:
     type: DUT
     host: "10.30.51.22"
   DUT2:
     type: DUT
     host: "10.30.51.22"
@@ -52,12 +174,62 @@ nodes:
     password: Cisco1234
     interfaces:
       port1:
     password: Cisco1234
     interfaces:
       port1:
+        # t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
+        mac_address: "90:e2:ba:b5:01:d8"
+        pci_address: "0000:0a:00.0"
+        link: link2
+        model: Intel-X520-DA2
+      port2:
+        # t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
+        mac_address: "90:e2:ba:b5:01:d9"
+        pci_address: "0000:0a:00.1"
+        link: link12
+        model: Intel-X520-DA2
+      port3:
+        # t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
+        mac_address: "ec:bd:1d:08:8f:88"
+        pci_address: "0000:13:00.0"
+        link: link4
+        model: Cisco-VIC-1385
+      port4:
+        # t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
+        mac_address: "ec:bd:1d:08:8f:89"
+        pci_address: "0000:15:00.0"
+        link: link13
+        model: Cisco-VIC-1385
+      port5:
+        # t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:35:76:98"
+        pci_address: "0000:85:00.0"
+        link: link8
+        model: Intel-XL710
+      port6:
+        # t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
+        mac_address: "68:05:ca:35:76:9d"
+        pci_address: "0000:85:00.1"
+        link: link14
+        model: Intel-XL710
+      port7:
+        # t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
         mac_address: "3c:fd:fe:9c:ee:e4"
         pci_address: "0000:87:00.0"
         mac_address: "3c:fd:fe:9c:ee:e4"
         pci_address: "0000:87:00.0"
-        link: link2
+        link: link10
         model: Intel-X710
         model: Intel-X710
-      port3:
+      port8:
+        # t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
         mac_address: "3c:fd:fe:9c:ee:e5"
         pci_address: "0000:87:00.1"
         mac_address: "3c:fd:fe:9c:ee:e5"
         pci_address: "0000:87:00.1"
-        link: link3
+        link: link15
         model: Intel-X710
         model: Intel-X710
+      port9:
+        # t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
+        mac_address: "00:fe:c8:e4:eb:4b"
+        pci_address: "0000:06:00.0"
+        link: link4
+        model: Cisco-VIC-1227
+      port10:
+        # t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
+        mac_address: "00:fe:c8:e4:eb:4c"
+        pci_address: "0000:07:00.0"
+        link: link16
+        model: Cisco-VIC-1227