From: pmikus Date: Thu, 1 Jun 2023 06:08:54 +0000 (+0000) Subject: docs(infra): Add CX7 and CX6 cards X-Git-Url: https://gerrit.fd.io/r/gitweb?p=csit.git;a=commitdiff_plain;h=265352781a137add1dc01238f9594cdbde7d77ad docs(infra): Add CX7 and CX6 cards Signed-off-by: pmikus Change-Id: I06cb1356626f55b9de901ca72b194db1a46b7efa --- diff --git a/docs/content/infrastructure/fdio_dc_testbed_specifications.md b/docs/content/infrastructure/fdio_dc_testbed_specifications.md index 439cfc31dd..bbc487fcd6 100644 --- a/docs/content/infrastructure/fdio_dc_testbed_specifications.md +++ b/docs/content/infrastructure/fdio_dc_testbed_specifications.md @@ -135,7 +135,7 @@ Used for FD.io performance tests. ### 3-Node-Icelake Xeon Intel (3n-icx) -Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one +Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F3) and one TG (Server-Type-F3) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. @@ -143,24 +143,15 @@ Used for FD.io performance tests. ### 3-Node-SnowRidge Atom Intel (3n-snr) Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one -TG (Server-Type-F4) connected in a 3-node circular topology +TG (Server-Type-F5) connected in a 3-node circular topology ([Server Types](#server-types)). Used for FD.io performance tests. -### 2-Node-Full-SapphireRapids Xeon Intel (2nf-spr) - -One 2-Node-Full-SapphireRapids testbed includes one SUT (Server-Type-H1) and -one TG (Server-Type-H2) connected in a 2-node physical topology -with NUMA (socket) daisy chaining. For more detail see -[Server Types](#server-types) and [Testbed Topology-TODO](#TODO). -Used for FD.io performance tests in a full system SUT setup with all PCIe -Gen5 x16 lane slots populated with 2p200GbE NICs. - ### 2-Node-SapphireRapids Xeon Intel (2n-spr) Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and -one TG (Server-Type-H6) connected in a 2-node circular topology. For more -detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO). +one TG (Server-Type-H6) connected in a 2-node or 3-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. @@ -504,10 +495,10 @@ FD.io CSIT lab contains following server types: - PCIe Slot10 ff:00.xx: empty. 18. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing. - - Quantity: 8. + - Quantity: 4. - Physical connectivity: - IPMI and host management ports. - - NIC ports connected into 2-node or 3-node testbed topologies. + - NIC ports connected into 2-node topology. - Main HW configuration: - Chassis: SuperMicro SYS-740GP-TNRT. - Motherboard: Super X12DPG-QT6. @@ -521,11 +512,11 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. - Numa1: (x16, x16, x16 PCIe4.0 lanes) - PCIe Slot6 86:00.xx: empty. - - PCIe Slot8 af:00.xx: empty. + - PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox. - PCIe Slot10 d8:00.xx: empty. 19. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing. - - Quantity: 3. + - Quantity: 4. - Physical connectivity: - IPMI and host management ports. - NIC ports connected into 2-node testbed topologies. @@ -542,10 +533,31 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. - Numa1: (x16, x16, x16 PCIe4.0 lanes) - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel. + - PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox. + - PCIe Slot10 d8:00.xx: empty. + +20. **Server-Type-F3**: Purpose - Icelake Xeon TG or SUT for FD.io performance testing. + - Quantity: 6. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 3-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-740GP-TNRT. + - Motherboard: Super X12DPG-QT6. + - Processors: 2* Intel Platinum 8358 2.6 GHz. + - RAM Memory: 16* 16GB DDR4-3200. + - Disks: 2* 960GB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. + - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. + - Numa1: (x16, x16, x16 PCIe4.0 lanes) + - PCIe Slot6 86:00.xx: ConnectX6-2p100GE Mellanox. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -20. **Server-Type-F3**: Purpose - Icelake Xeon TG for FD.io performance testing. +21. **Server-Type-F4**: Purpose - Icelake Xeon TG for FD.io performance testing. - Quantity: 3. - Physical connectivity: - IPMI and host management ports. @@ -562,11 +574,11 @@ FD.io CSIT lab contains following server types: - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel. - Numa1: (x16, x16, x16 PCIe4.0 lanes) - - PCIe Slot6 86:00.xx: empty. + - PCIe Slot6 86:00.xx: ConnectX6-2p100GE Mellanox. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -21. **Server-Type-F4**: Purpose - Icelake Xeon Shared TG for FD.io performance testing. +22. **Server-Type-F5**: Purpose - Icelake Xeon Shared TG for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -587,7 +599,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel. - PCIe Slot10 ff:00.xx: empty. -22. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing. +23. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: - IPMI and host management ports. @@ -602,7 +614,7 @@ FD.io CSIT lab contains following server types: - Numa0: (x16, PCIe3.0 lane) - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel. -23. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing. +24. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -623,7 +635,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. -24. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. +25. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -644,7 +656,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia. - PCIe Slot11 d8:00.xx: empty. -25. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. +26. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -665,7 +677,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel. - PCIe Slot11 d8:00.xx: empty. -26. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. +27. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -686,7 +698,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: empty. - PCIe Slot11 d8:00.xx: empty. -27. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. +28. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -707,7 +719,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot9 af:00.xx: empty. - PCIe Slot11 d8:00.xx: empty. -28. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. +29. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -1034,6 +1046,8 @@ FD.io CSIT lab contains following server types: - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s71-t212-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE. + - s71-t212-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE. - TG [Server-Type-F2]: - testbedname: testbed212. - hostname: s72-t212-tg1. @@ -1050,6 +1064,8 @@ FD.io CSIT lab contains following server types: - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s72-t212-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE. + - s72-t212-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE. - SUT [Server-Type-F1]: - testbedname: testbed213. - hostname: s83-t213-sut1. @@ -1064,6 +1080,8 @@ FD.io CSIT lab contains following server types: - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s83-t213-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE. + - s83-t213-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE. - TG [Server-Type-F2]: - testbedname: testbed213. - hostname: s84-t213-tg1. @@ -1080,6 +1098,8 @@ FD.io CSIT lab contains following server types: - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s84-t213-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE. + - s84-t213-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE. - SUT [Server-Type-F1]: - testbedname: testbed214. - hostname: s85-t214-sut1. @@ -1094,6 +1114,8 @@ FD.io CSIT lab contains following server types: - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s85-t214-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE. + - s85-t214-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE. - TG [Server-Type-F2]: - testbedname: testbed214. - hostname: s86-t214-tg1. @@ -1110,6 +1132,8 @@ FD.io CSIT lab contains following server types: - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s86-t214-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE. + - s86-t214-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE. - SUT [Server-Type-F1]: - testbedname: testbed215. - hostname: s87-t215-sut1. @@ -1124,6 +1148,8 @@ FD.io CSIT lab contains following server types: - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s87-t215-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE. + - s87-t215-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE. - TG [Server-Type-F2]: - testbedname: testbed215. - hostname: s88-t215-tg1. @@ -1140,6 +1166,8 @@ FD.io CSIT lab contains following server types: - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s88-t215-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE. + - s88-t215-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE. ``` ### 3-Node-Rangeley (3n-rng) @@ -1269,7 +1297,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. {{< figure src="/cdocs/testbed-3n-icx.svg" >}} ``` -- ServerF1 [Server-Type-F1]: +- SUT1 [Server-Type-F3]: - testbedname: testbed37. - hostname: s65-t37-sut1. - IPMI IP: 10.30.50.75 @@ -1283,7 +1311,9 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF1 [Server-Type-F1]: + - s65-t37-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. + - s65-t37-sut1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. +- SUT2 [Server-Type-F3]: - testbedname: testbed37. - hostname: s66-t37-sut2. - IPMI IP: 10.30.50.76 @@ -1297,7 +1327,9 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF3 [Server-Type-F3]: + - s65-t37-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. + - s65-t37-sut1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. +- TG [Server-Type-F3]: - testbedname: testbed37. - hostname: s67-t37-tg1. - IPMI IP: 10.30.50.77 @@ -1311,7 +1343,9 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF1 [Server-Type-F1]: + - s67-t37-tg1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. + - s67-t37-tg1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. +- SUT1 [Server-Type-F3]: - testbedname: testbed38. - hostname: s78-t38-sut1. - IPMI IP: 10.30.50.78 @@ -1325,7 +1359,9 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF1 [Server-Type-F1]: + - s78-t38-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. + - s78-t38-sut1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. +- SUT2 [Server-Type-F3]: - testbedname: testbed38. - hostname: s79-t38-sut2. - IPMI IP: 10.30.50.79 @@ -1339,7 +1375,9 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. -- ServerF3 [Server-Type-F3]: + - s79-t38-sut2-c6/p1 - 100GE-port1 ConnectX6-2p100GE. + - s79-t38-sut2-c6/p2 - 100GE-port1 ConnectX6-2p100GE. +- TG [Server-Type-F3]: - testbedname: testbed38. - hostname: s80-t38-tg1. - IPMI IP: 10.30.50.80 @@ -1353,6 +1391,8 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE. - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE. - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE. + - s80-t38-tg1-c6/p1 - 100GE-port1 ConnectX6-2p100GE. + - s80-t38-tg1-c6/p2 - 100GE-port1 ConnectX6-2p100GE. ``` ### 3-Node-SnowRidge (3n-snr) @@ -1380,7 +1420,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE. - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE. - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE. -- ServerF4 [Server-Type-F4]: +- ServerF4 [Server-Type-F5]: - testbedname: testbed39. - hostname: s89-t39t310-tg1. - IPMI IP: 10.30.50.89 @@ -1686,65 +1726,77 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. ``` - testbed212: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - ring1 25GE-ports xxv710-DA2-2p25GE: - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1. - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - ring2 25GE-ports e810-XXVDA4-2p25GE: - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1. - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2. - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3. - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - ring3 100GE-ports e810-2CQDA2-2p100GE: - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1. - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2. - - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - ring4 100GE-ports e810-2CQDA2-2p100GE: - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2. - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1. + - ring5 100GE-ports ConnectX7-2p100GE: + - s72-t212-tg1-c8/p1 to s71-t212-sut1-c8/p1. + - s71-t212-sut1-c8/p2 to s72-t212-tg1-c8/p2. - testbed213: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - ring1 25GE-ports xxv710-DA2-2p25GE: - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1. - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - ring2 25GE-ports e810-XXVDA4-2p25GE: - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1. - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2. - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3. - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - ring3 100GE-ports e810-2CQDA2-2p100GE: - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1. - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2. - - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - ring4 100GE-ports e810-2CQDA2-2p100GE: - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2. - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1. + - ring5 100GE-ports ConnectX7-2p100GE: + - s84-t213-tg1-c8/p1 to s83-t213-sut1-c8/p1. + - s83-t213-sut1-c8/p2 to s84-t213-tg1-c8/p2. - testbed214: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - ring1 25GE-ports xxv710-DA2-2p25GE: - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1. - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - ring2 25GE-ports e810-XXVDA4-2p25GE: - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1. - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2. - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3. - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - ring3 100GE-ports e810-2CQDA2-2p100GE: - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1. - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2. - - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - ring4 100GE-ports e810-2CQDA2-2p100GE: - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2. - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1. + - ring5 100GE-ports ConnectX7-2p100GE: + - s86-t214-tg1-c8/p1 to s85-t214-sut1-c8/p1. + - s85-t214-sut1-c8/p2 to s86-t214-tg1-c8/p2. - testbed215: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUT + - ring1 25GE-ports xxv710-DA2-2p25GE: - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1. - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT: + - ring2 25GE-ports e810-XXVDA4-2p25GE: - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1. - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2. - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3. - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT: + - ring3 100GE-ports e810-2CQDA2-2p100GE: - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1. - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2. - - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT: + - ring4 100GE-ports e810-2CQDA2-2p100GE: - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2. - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1. + - ring5 100GE-ports ConnectX7-2p100GE: + - s88-t215-tg1-c8/p1 to s87-t215-sut1-c8/p1. + - s87-t215-sut1-c8/p2 to s88-t215-tg1-c8/p2. ``` ### 3-Node-Rangeley (3n-rng) @@ -1785,37 +1837,45 @@ To be completed. ``` - testbed37: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: + - ring1 25GE-ports xxv710-DA2-2p25GE: - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1. - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2. - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: + - ring2 25GE-ports e810-XXVDA4-4p25GE: - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1. - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2. - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2. - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3. - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4. - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT + - ring3 100GE-ports e810-2CQDA2-2p100GE: - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1. - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2. - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2. + - ring4 100GE-ports ConnectX6-2p100GE: + - s67-t37-tg1-c6/p1 - s65-t37-sut1-c6/p2. + - s65-t37-sut1-c6/p1 - s66-t37-sut2-c6/p2. + - s66-t37-sut2-c6/p1 - s67-t37-tg1-c9-c6/p2. - testbed38: - - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs: + - ring1 25GE-ports xxv710-DA2-2p25GE: - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1. - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2. - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2. - - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT: + - ring2 25GE-ports e810-XXVDA4-4p25GE: - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1. - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2. - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2. - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3. - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4. - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4. - - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT + - ring3 100GE-ports e810-2CQDA2-2p100GE: - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1. - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2. - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2. + - ring4 100GE-ports ConnectX6-2p100GE: + - s80-t38-tg1-c6/p1 to s78-t38-sut1-c6/p1. + - s78-t38-sut1-c6/p2 to s79-t38-sut2-c6/p2. + - s79-t38-sut2-c6/p1 to s80-t38-tg1-c6/p2. ``` ### 3-Node-SnowRidge (3n-snr)