From 71151aa84d7e9c2da3b22789535aefb1f381ff87 Mon Sep 17 00:00:00 2001 From: Maciek Konstantynowicz Date: Wed, 24 Jul 2019 19:15:14 +0100 Subject: [PATCH] docs: updated testbed specification with clx build Change-Id: Idaea4ac8ba04bea591ade511f55a5e421d04b8f5 Signed-off-by: Maciek Konstantynowicz --- docs/lab/testbed_specifications.md | 550 +++++++++++++++++++++++++++---------- 1 file changed, 408 insertions(+), 142 deletions(-) diff --git a/docs/lab/testbed_specifications.md b/docs/lab/testbed_specifications.md index afa36ff56c..6c04bfbdad 100644 --- a/docs/lab/testbed_specifications.md +++ b/docs/lab/testbed_specifications.md @@ -5,9 +5,11 @@ 1. [Summary List](#summary-list) 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx) 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2) + 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx) 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx) 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv) 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1) + 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx) 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx) 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx) 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh) @@ -18,15 +20,18 @@ 1. [Addressing](#addressing) 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses) 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses) -1. [Server Type Specification](#server-type-specification) - 1. [Server and Port Naming](#server-and-port-naming) +1. [Server Specifications](#server-specifications) + 1. [Server Types](#server-types) + 1. [Naming Convention](#naming-convention) 1. [Testbeds Configuration](#testbeds-configuration) 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming) 1. [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod) 1. [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip) + 1. [1-Node-Cascadelake (1n-clx) SETUP](#1-node-cascadelake-1n-clx-setup) 1. [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod) 1. [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo) 1. [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify) + 1. [2-Node-Cascadelake (2n-clx) SETUP](#2-node-cascadelake-2n-clx-setup) 1. [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod) 1. [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod) 1. [3-Node-Rangeley (3n-rng) VERIFY](#3-node-rangeley-3n-rng-verify) @@ -35,9 +40,11 @@ 1. [Per Testbed Wiring](#per-testbed-wiring) 1. [1-Node-Skylake (1n-skx) PROD](#1-node-skylake-1n-skx-prod) 1. [1-Node-Thunderx2 (1n-tx2) WIP](#1-node-thunderx2-1n-tx2-wip) + 1. [1-Node-Cascadelake (1n-clx) SETUP](#1-node-cascadelake-1n-clx-setup) 1. [2-Node-Skylake (2n-skx) PROD](#2-node-skylake-2n-skx-prod) 1. [2-Node-Denverton (2n-dnv) TODO](#2-node-denverton-2n-dnv-todo) 1. [2-Node-IxiaPS1L47 (2n-ps1) VERIFY](#2-node-ixiaps1l47-2n-ps1-verify) + 1. [2-Node-Cascadelake (2n-clx) SETUP](#2-node-cascadelake-2n-clx-setup) 1. [3-Node-Haswell (3n-hsw) PROD](#3-node-haswell-3n-hsw-prod) 1. [3-Node-Skylake (3n-skx) PROD](#3-node-skylake-3n-skx-prod) 1. [3-Node-Rangeley (3n-rng) TODO](#3-node-rangeley-3n-rng-todo) @@ -62,79 +69,102 @@ hosted by LFN FD.io CSIT project. ``` #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb - 1. 1-Node-Skylake func skx na 2 2 0 0 2 0 0 0 0 0 0 - 2. 1-Node-Thunderx2 func tx2 na 1 1 0 0 0 0 0 0 1 0 0 - 3. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 - 4. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 - 5. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 - 6. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 - 7. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 - 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 - 9. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0 -10. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2 -11. 1-Node-VIRL func hsw --- 3 3 0 3 0 0 0 0 0 0 0 -12. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 - Totals: 18 28 15 12 19 1 2 3 1 2 2 + 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 + 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 + 3. 1-Node-Thunderx2 dev tx2 na 1 1 0 0 0 0 0 0 1 0 0 + 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 + 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 + 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 + 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 + 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 + 9. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 +10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 +11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 +12. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0 +13. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2 +14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 + Totals: 22 35 18 12 19 1 2 3 1 2 2 ``` ### 1-Node-Skylake Xeon Intel (1n-skx) -Each 1-Node-Skylake testbed includes one SUT (Type-B6 server) with NIC -ports connected back-to-back. +Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC +ports connected back-to-back ([Server Types](#server-types)). Used for FD.io VPP_Device functional driver tests. ### 1-Node-ThunderX2 Arm Marvell (1n-tx2) -Each 1-Node-ThunderX2 testbed includes one SUT (Type-B9 server) with NIC -ports connected back-to-back. +Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC +ports connected back-to-back ([Server Types](#server-types)). +Used for FD.io VPP_Device functional driver tests. + +### 1-Node-Cascadelake Xeon Intel (1n-clx) + +Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with +NIC ports connected back-to-back ([Server Types](#server-types)). + Used for FD.io VPP_Device functional driver tests. ### 2-Node-Skylake Xeon Intel (2n-skx) -Each 2-Node-Skylake testbed includes one SUT (Type-B1 server) and one TG -(Type-B2 server) connected back-to-back. +Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG +(Server-Type-B2) connected in a 2-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. ### 2-Node-Denverton Atom Intel (2n-dnv) -Each 2-Node-Skylake testbed includes one SUT (Type-B10 server) and one TG -(Type-B2 server) connected back-to-back. +Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one +TG (Server-Type-B2) connected in a 2-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1) -Each 2-Node-IxiaPS1L47 testbed includes one SUT (Type-B1 server) and one -TG (Ixia PSOne appliance) with 10GE interfaces connected back-to-back. +Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one +TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node +circular topology ([Server Types](#server-types)). Used for FD.io TCP/IP and HTTP performance tests. +### 2-Node-Cascadelake Xeon Intel (2n-clx) + +Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and +one TG (Server-Type-C3) connected in a 2-node circular topology +([Server Types](#server-types)). +Used for FD.io performance tests. + ### 3-Node-Haswell Xeon Intel (3n-hsw) -Each 3-Node-Haswell testbed includes two SUTs (Type-A1 servers) and one -TG (Type-A2 server) connected in full-mesh triangle. +Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one +TG (Server-Type-A2) connected in a 3-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. ### 3-Node-Skylake Xeon Intel (3n-skx) -Each 3-Node-Skylake testbed includes two SUTs (Type-B1 servers) and one -TG (Type-B2 server) connected in full-mesh triangle. +Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one +TG (Server-Type-B2) connected in a 3-node circular topology. Used for FD.io performance tests. ### 3-Node-TaiShan Arm Huawei (3n-tsh) -Each 3-Node-TaiShan testbed includes two SUTs (Type-B3 server) and one TG -(Type-B2 server) connected in full-mesh triangle. +Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one +TG (Server-Type-B2) connected in a 3-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. ### 3-Node-MACCHIATObin Arm Marvell -Each 3-Node-MACCHIATObin testbed includes two SUTs (Type-B4 server) and -one TG (Type-B2 server) connected in full-mesh triangle. +Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and +one TG (Server-Type-B2) connected in a 3-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. ### 3-Node-Rangeley Atom Testbeds -Each 3-Node-Rangeley testbed includes two SUTs (Type-B5 Netgate device) -and one TG (Type-2 server) connected in full-mesh triangle. +Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one +TG (Server-Type-2) connected in a 3-node circular topology +([Server Types](#server-types)). Used for FD.io performance tests. ## Server Management @@ -147,16 +177,16 @@ connected to the management network: ``` - 1GE IPMI port - IPMI - Intelligent Platform Management Interface. - - Required for access to embedded server management with WebUI, CLI, SNMPv3, - IPMIv2.0, for firmware (BIOS) and OS updates. + - Required for access to embedded server management with WebUI, CLI, + SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates. - 1GE/10GE/40GE management port - hostOS management port for general system management. ``` ### Addressing -Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management -port, which are connected to two different VLANs. +Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a +Management port, which are connected to two different VLANs. ``` 1. LOM (IPMI) VLAN: @@ -229,7 +259,23 @@ Name | Comment 10.30.50.58 | s25-t25-sut1 10.30.50.59 | s26-t25-tg1 10.30.50.69 | s27-t13-sut +n/a | s20-t34-sut1 +n/a | s21-t34-sut2 +10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyUSB0 +10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyUSB1 +10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyUSB2 +10.30.55.10 | s28-t26t35-tg1 +10.30.55.11 | s29-t26-sut1 +10.30.55.12 | s30-t35-sut1 +10.30.55.13 | s31-t35-sut2 10.30.50.255 | Broadcast +x.x.x.x | s32-t14-sut1 +x.x.x.x | s33-t27-sut1 +x.x.x.x | s34-t27-tg1 +x.x.x.x | s35-t28-sut1 +x.x.x.x | s36-t28-tg1 +x.x.x.x | s37-t29-sut1 +x.x.x.x | s38-t29-tg1 ### Management VLAN IP Addresses @@ -294,12 +340,25 @@ Name | Comment 10.30.51.106-10.30.51.180 | VIRL2 10.30.51.181-10.30.51.254 | VIRL3 10.30.51.255 | Broadcast - -## Server Type Specification +10.32.8.10 | s28-t26t35-tg1 +10.32.8.11 | s29-t26-sut1 +10.32.8.12 | s30-t35-sut1 +10.32.8.13 | s31-t35-sut2 +x.x.x.x | s32-t14-sut1 +x.x.x.x | s33-t27-sut1 +x.x.x.x | s34-t27-tg1 +x.x.x.x | s35-t28-sut1 +x.x.x.x | s36-t28-tg1 +x.x.x.x | s37-t29-sut1 +x.x.x.x | s38-t29-tg1 + +## Server Specifications + +### Server Types FD.io CSIT lab contains following server types: ``` -1. Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing. +1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing. - Quantity: 6 servers. - Physical connectivity: - CIMC and host management ports. @@ -319,7 +378,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot5: Intel NIC x710 2p10GE. - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill) - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes). -2. Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing. +2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing. - Quantity: 3 servers. - Physical connectivity: - CIMC and host management ports. @@ -339,7 +398,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot5: Intel NIC x710 2p10GE. - PCIe Slot6: Intel NIC x710 2p10GE. - MLOM slot: empty. -3. Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing. +3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing. - Quantity: 3 servers. - Physical connectivity: - CIMC and host management ports. @@ -355,7 +414,7 @@ FD.io CSIT lab contains following server types: - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes) - no cards. - MLOM slot: empty. -4. Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing. +4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing. - Quantity: --- - Physical connectivity: - IPMI and host management ports. @@ -363,19 +422,19 @@ FD.io CSIT lab contains following server types: - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. - - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox. + - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -2. Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing. +2. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing. - Quantity: --- - Physical connectivity: - IPMI and host management ports. @@ -383,19 +442,19 @@ FD.io CSIT lab contains following server types: - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: - Numa0: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot2 18:00.xx: x710-4p10GE Intel. - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. - - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox. + - PCIe Slot9 5e:00.xx: empty. - Numa1: (x16, x16, x16 PCIe3.0 lanes) - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. -3. Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. +3. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing. - Quantity: 2 - Physical connectivity: - IPMI(?) and host management ports. @@ -408,7 +467,7 @@ FD.io CSIT lab contains following server types: - NICs configuration: - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox. - PCIe Slot6 11:00.xx: x520-2p10GE Intel. -4. Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing. +4. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing. - Quantity: 3 - Physical connectivity: - Host management ports. @@ -420,7 +479,7 @@ FD.io CSIT lab contains following server types: - Disks: 1* 128GB(?) SATA SDD - NICs configuration: - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP) -5. Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing. +5. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing. - Quantity: TBD based on testbed allocation. - Physical connectivity: - Management: serial Port (usb) for console @@ -433,7 +492,7 @@ FD.io CSIT lab contains following server types: - NICs configuration: - 2x 10Gb Intel 82599ES - 4x 1GB Intel I354 -6. Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. +6. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests. - Quantity: 2. - Physical connectivity: - IPMI and host management ports. @@ -441,7 +500,7 @@ FD.io CSIT lab contains following server types: - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: @@ -453,7 +512,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -7. Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. +7. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests. - Quantity: 1. - Physical connectivity: - Host management interface: 10/100/1000-BaseT. @@ -472,7 +531,7 @@ FD.io CSIT lab contains following server types: - Port-2: 10GE SFP+. - Port-3: 10GE SFP+. - Port-4: 10GE SFP+. -8. Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. +8. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests. - Quantity: 1. - Physical connectivity: - IPMI and host management ports. @@ -480,7 +539,7 @@ FD.io CSIT lab contains following server types: - Main HW configuration: - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. - NICs configuration: @@ -492,7 +551,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot6 86:00.xx: empty. - PCIe Slot8 af:00.xx: empty. - PCIe Slot10 d8:00.xx: empty. -9. Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. +9. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests. - Quantity: 1 - Physical connectivity: - IPMI and host management ports. @@ -509,7 +568,7 @@ FD.io CSIT lab contains following server types: - PCIe Slot3 08:00.xx: XL710-QDA2. - Numa1: - PCIe Slot6 85:00.xx: XL710-QDA2. -10. Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing. +10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing. - Quantity: 4 - Physical connectivity: - IPMI and host management ports. @@ -523,9 +582,90 @@ FD.io CSIT lab contains following server types: - 2x 10Gb Intel x553 fiber ports - 2x 10Gb Intel x553 copper ports - 4x 1GB Intel I350 ports + +6. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 1-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8280 2.7 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 2* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. + +4. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing. + - Quantity: 3 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Gold 6252N 2.3 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 2* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. + - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +2. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing. + - Quantity: 3. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node testbed topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8280 2.7 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 2* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. + - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox. + - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. + +3. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing. + - Quantity: 3. + - Physical connectivity: + - CIMC and host management ports. + - no NIC ports, standalone setup. + - Main HW configuration: + - Chassis: SuperMicro 1029P-WTRT. + - Motherboard: SuperMicro X11DDW-NT. + - Processors: 2* Intel Platinum 8280 2.7 GHz. + - RAM Memory: 12* 16GB DDR4-2933. + - Disks: 4* 1.92TB SATA SSD. + - NICs configuration: + - Numa0: + - no cards. + - Numa1: + - no cards. ``` -### Server and Port Naming +### Naming Convention Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds: @@ -553,7 +693,7 @@ connectivity and wiring across defined CSIT testbeds: #### 1-Node-Skylake (1n-skx) PROD ``` -- ServerB1 [Type-B6]: +- SUT [Server-Type-B6]: - testbedname: testbed11. - hostname: s1-t11-sut1. - IPMI IP: 10.30.50.47 @@ -567,7 +707,7 @@ connectivity and wiring across defined CSIT testbeds: - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE. - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE. - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE. -- ServerB2 [Type-B6]: +- SUT [Server-Type-B6]: - testbedname: testbed12. - hostname: s2-t12-sut1. - IPMI IP: 10.30.50.48 @@ -586,7 +726,7 @@ connectivity and wiring across defined CSIT testbeds: #### 1-Node-Thunderx2 (1n-tx2) WIP ``` -- ServerB17 [Type-B9]: +- SUT [Server-Type-B9]: - testbedname: testbed13. - hostname: s27-t13-sut1. - IPMI IP: 10.30.50.69 @@ -600,10 +740,29 @@ connectivity and wiring across defined CSIT testbeds: - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE. ``` +#### 1-Node-Cascadelake (1n-clx) SETUP + +``` +- SUT [Server-Type-C1]: + - testbedname: testbed11. + - hostname: s32-t14-sut1. + - IPMI IP: x.x.x.x + - Host IP: x.x.x.x + - portnames: + - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE. + - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE. + - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE. + - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE. +``` + #### 2-Node-Skylake (2n-skx) PROD ``` -- ServerB3 [Type-B1]: +- SUT [Server-Type-B1]: - testbedname: testbed21. - hostname: s3-t21-sut1. - IPMI IP: 10.30.50.41 @@ -615,9 +774,7 @@ connectivity and wiring across defined CSIT testbeds: - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB4 [Type-B2]: +- TG [Server-Type-B2]: - testbedname: testbed21. - hostname: s4-t21-tg1. - IPMI IP: 10.30.50.42 @@ -629,9 +786,7 @@ connectivity and wiring across defined CSIT testbeds: - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB5 [Type-B1]: +- SUT [Server-Type-B1]: - testbedname: testbed22. - hostname: s5-t22-sut1. - IPMI IP: 10.30.50.49 @@ -643,9 +798,7 @@ connectivity and wiring across defined CSIT testbeds: - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB6 [Type-B2]: +- TG [Server-Type-B2]: - testbedname: testbed22. - hostname: s6-t22-tg1. - IPMI IP: 10.30.50.50 @@ -657,9 +810,7 @@ connectivity and wiring across defined CSIT testbeds: - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB7 [Type-B1]: +- SUT [Server-Type-B1]: - testbedname: testbed23. - hostname: s7-t23-sut1. - IPMI IP: 10.30.50.51 @@ -671,9 +822,7 @@ connectivity and wiring across defined CSIT testbeds: - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB8 [Type-B2]: +- TG [Server-Type-B2]: - testbedname: testbed23. - hostname: s8-t23-tg1. - IPMI IP: 10.30.50.52 @@ -685,9 +834,7 @@ connectivity and wiring across defined CSIT testbeds: - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB9 [Type-B1]: +- SUT [Server-Type-B1]: - testbedname: testbed24. - hostname: s9-t24-sut1. - IPMI IP: 10.30.50.53 @@ -699,9 +846,7 @@ connectivity and wiring across defined CSIT testbeds: - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE. - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB10 [Type-B2]: +- TG [Server-Type-B2]: - testbedname: testbed24. - hostname: s10-t24-tg1. - IPMI IP: 10.30.50.54 @@ -713,8 +858,6 @@ connectivity and wiring across defined CSIT testbeds: - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE. - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. ``` #### 2-Node-Denverton (2n-dnv) WIP @@ -722,7 +865,7 @@ connectivity and wiring across defined CSIT testbeds: Note: ServerB28 (TG) is shared between testbed26 & testbed35 ``` -- ServerB28 [Type-B2]: +- TG [Server-Type-B2]: - testbednames: testbed26 and testbed35. - hostname: s28-t26t35-tg1. - IPMI IP: 10.30.55.10 @@ -740,7 +883,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE. - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE. - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE. -- ServerB29 [Type-B10]: +- SUT [Server-Type-B10]: - testbednames: testbed26. - hostname: s29-t26-sut1. - IPMI IP: 10.30.55.11 @@ -755,7 +898,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 #### 2-Node-IxiaPS1L47 (2n-ps1) VERIFY ``` -- ServerB25 [Type-B8]: +- SUT [Server-Type-B8]: - testbedname: testbed25. - hostname: s25-t25-sut1. - IPMI IP: 10.30.50.58 @@ -765,7 +908,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE. - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE. - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE. -- ServerB26 [Type-B7]: +- TG [Server-Type-B7]: - testbedname: testbed25. - hostname: s26-t25-tg1. - IPMI IP: 10.30.50.59 @@ -777,10 +920,99 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s26-t25-tg1-p4 - 10GE-port4. ``` +#### 2-Node-Cascadelake (2n-clx) SETUP + +``` +- SUT [Server-Type-C2]: + - testbedname: testbed27. + - hostname: s33-t27-sut1. + - IPMI IP: x.x.x.x + - Host IP: x.x.x.x + - portnames: + - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-C3]: + - testbedname: testbed27. + - hostname: s34-t27-tg1. + - IPMI IP: x.x.x.x + - Host IP: x.x.x.x + - portnames: + - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- SUT [Server-Type-C2]: + - testbedname: testbed28. + - hostname: s35-t28-sut1. + - IPMI IP: x.x.x.x + - Host IP: x.x.x.x + - portnames: + - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-C3]: + - testbedname: testbed28. + - hostname: s36-t28-tg1. + - IPMI IP: x.x.x.x + - Host IP: x.x.x.x + - portnames: + - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE. + - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE. +- SUT [Server-Type-C2]: + - testbedname: testbed29. + - hostname: s37-t29-sut1. + - IPMI IP: x.x.x.x + - Host IP: x.x.x.x + - portnames: + - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- TG [Server-Type-C3]: + - testbedname: testbed29. + - hostname: s38-t29-tg1. + - IPMI IP: x.x.x.x + - Host IP: x.x.x.x + - portnames: + - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +``` + #### 3-Node-Haswell (3n-hsw) PROD ``` - 1. Server1 of Type-1: + 1. SUT [Server-Type-A1]: - testbedname: testbed1. - hostname: t1-sut1. - CIMC IP: 10.30.50.17 @@ -796,7 +1028,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 2. Server2 of Type-1: + 2. SUT [Server-Type-A1]: - testbedname: testbed1. - hostname: t1-sut2. - CIMC IP: 10.30.50.18 @@ -812,7 +1044,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 3. Server3 of Type-2: + 3. TG [Server-Type-A2]: - testbedname: testbed1. - hostname: t1-tg1. - CIMC IP: 10.30.50.16 @@ -830,7 +1062,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. - 4. Server4 of Type-1: + 4. SUT [Server-Type-A1]: - testbedname: testbed2. - hostname: t2-sut1. - CIMC IP: 10.30.50.21 @@ -846,7 +1078,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 5. Server5 of Type-1: + 5. SUT [Server-Type-A1]: - testbedname: testbed2. - hostname: t2-sut2. - CIMC IP: 10.30.50.22 @@ -862,7 +1094,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 6. Server6 of Type-2: + 6. TG [Server-Type-A2]: - testbedname: testbed2. - hostname: t2-tg1. - CIMC IP: 10.30.50.20 @@ -880,7 +1112,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE. - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE. - 7. Server7 of Type-1: + 7. SUT [Server-Type-A1]: - testbedname: testbed3. - hostname: t3-sut1. - CIMC IP: 10.30.50.25 @@ -896,7 +1128,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 8. Server8 of Type-1: + 8. SUT [Server-Type-A1]: - testbedname: testbed3. - hostname: t3-sut2. - CIMC IP: 10.30.50.26 @@ -912,7 +1144,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE. - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE. - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE. - 9. Server9 of Type-2: + 9. TG [Server-Type-A2]: - testbedname: testbed3. - hostname: t3-tg1. - CIMC IP: 10.30.50.24 @@ -935,7 +1167,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 #### 3-Node-Skylake (3n-skx) PROD ``` -- ServerB11 [Type-B1]: +- ServerB11 [Server-Type-B1]: - testbedname: testbed31. - hostname: s11-t31-sut1. - IPMI IP: 10.30.50.43 @@ -949,7 +1181,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB12 [Type-B1]: +- ServerB12 [Server-Type-B1]: - testbedname: testbed31. - hostname: s12-t31-sut2. - IPMI IP: 10.30.50.44 @@ -963,7 +1195,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB13 [Type-B2]: +- ServerB13 [Server-Type-B2]: - testbedname: testbed31. - hostname: s13-t31-tg1. - IPMI IP: 10.30.50.45 @@ -977,7 +1209,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB14 [Type-B1]: +- ServerB14 [Server-Type-B1]: - testbedname: testbed32. - hostname: s14-t32-sut1. - IPMI IP: 10.30.50.55 @@ -991,7 +1223,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB15 [Type-B1]: +- ServerB15 [Server-Type-B1]: - testbedname: testbed32. - hostname: s15-t32-sut2. - IPMI IP: 10.30.50.56 @@ -1005,7 +1237,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. -- ServerB16 [Type-B2]: +- ServerB16 [Server-Type-B2]: - testbedname: testbed32. - hostname: s16-t32-tg1. - IPMI IP: 10.30.50.57 @@ -1026,7 +1258,7 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. ``` -- ServerB22 [Type-B5]: +- ServerB22 [Server-Type-B5]: - testbedname: testbed35. - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1). - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0 @@ -1035,7 +1267,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s22-t35-sut1-p1 - 10GE-port1 ix0 82599. - s22-t35-sut1-p2 - 10GE-port2 ix1 82599. - 1GB ports (tbd) -- ServerB23 [Type-B5]: +- ServerB23 [Server-Type-B5]: - testbedname: testbed35. - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2). - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1 @@ -1044,7 +1276,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. - s23-t35-sut1-p1 - 10GE-port1 ix0 82599. - s23-t35-sut1-p2 - 10GE-port2 ix1 82599. - 1GB ports (tbd) -- ServerB24 [Type-B5]: +- ServerB24 [Server-Type-B5]: - testbedname: testbed35. - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3). - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2 @@ -1060,7 +1292,7 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. Note: ServerB19 (TG) is shared between testbed33 & testbed34 ``` -- ServerB17 [Type-B3]: +- ServerB17 [Server-Type-B3]: - testbedname: testbed33. - hostname: s17-t33-sut1. - IPMI IP: 10.30.50.36 @@ -1070,7 +1302,7 @@ Note: ServerB19 (TG) is shared between testbed33 & testbed34 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE. - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE. - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE. -- ServerB18 [Type-B3]: +- ServerB18 [Server-Type-B3]: - testbedname: testbed33. - hostname: s18-t33-sut2. - IPMI IP: 10.30.50.37 @@ -1080,7 +1312,7 @@ Note: ServerB19 (TG) is shared between testbed33 & testbed34 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE. - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE. - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE. -- ServerB19 [Type-B2]: +- ServerB19 [Server-Type-B2]: - testbednames: testbed33 and testbed34. - hostname: s19-t33t34-tg1. - IPMI IP: 10.30.50.46 @@ -1096,7 +1328,7 @@ Note: ServerB19 (TG) is shared between testbed33 & testbed34 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE. - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE. - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE. -- ServerB20 [Type-B4]: +- ServerB20 [Server-Type-B4]: - testbedname: testbed34. - hostname: s20-t34-sut1. - IPMI IP: N/A @@ -1104,7 +1336,7 @@ Note: ServerB19 (TG) is shared between testbed33 & testbed34 - portnames: - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell. - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell. -- ServerB21 [Type-B4]: +- ServerB21 [Server-Type-B4]: - testbedname: testbed34. - hostname: s21-t34-sut2. - IPMI IP: N/A @@ -1117,7 +1349,7 @@ Note: ServerB19 (TG) is shared between testbed33 & testbed34 #### 3-Node-Denverton (3n-dnv) WIP ``` -- ServerB30 [Type-B10]: +- ServerB30 [Server-Type-B10]: - testbednames: testbed35. - hostname: s30-t35-sut1. - IPMI IP: 10.30.55.12 @@ -1127,7 +1359,7 @@ Note: ServerB19 (TG) is shared between testbed33 & testbed34 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port. - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port. - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port. -- ServerB31 [Type-B10]: +- ServerB31 [Server-Type-B10]: - testbednames: testbed35. - hostname: s31-t35-sut2. - IPMI IP: 10.30.55.13 @@ -1182,6 +1414,20 @@ To be completed. - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1. ``` +#### 1-Node-Cascadelake (1n-clx) SETUP + +``` +- testbed14: + - ring1 10GE-ports x710-4p10GE: + - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1. + - ring2 10GE-ports x710-4p10GE: + - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2. + - ring3 10GE-ports x710-4p10GE: + - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3. + - ring4 10GE-ports x710-4p10GE: + - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3. +``` + #### 2-Node-Skylake (2n-skx) PROD ``` @@ -1195,12 +1441,6 @@ To be completed. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1. - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1. - - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2. - - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2. - - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4. - testbed22: - ring1 10GE-ports x710-4p10GE on SUT: - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1. @@ -1211,12 +1451,6 @@ To be completed. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1. - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1. - - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2. - - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2. - - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4. - testbed23: - ring1 10GE-ports x710-4p10GE on SUT: - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1. @@ -1227,12 +1461,6 @@ To be completed. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1. - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1. - - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2. - - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2. - - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4. - testbed24: - ring1 10GE-ports x710-4p10GE on SUT: - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1. @@ -1243,12 +1471,6 @@ To be completed. - ring3 25GE-ports xxv710-DA2-2p25GE on SUT - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1. - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2. - - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: - - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1. - - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2. - - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: - - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2. - - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4. ``` #### 2-Node-Denverton (2n-dnv) WIP @@ -1277,6 +1499,50 @@ To be completed. - t25-tg1-p4 to t25-sut1-c2/p4. ``` +#### 2-Node-Cascadelake (2n-clx) SETUP + +``` +- testbed27: + - ring1 10GE-ports x710-4p10GE on SUT: + - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1. + - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3. + - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1. + - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2. + - ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1. + - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2. +- testbed28: + - ring1 10GE-ports x710-4p10GE on SUT: + - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1. + - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3. + - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1. + - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2. + - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1. + - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2. +- testbed29: + - ring1 10GE-ports x710-4p10GE on SUT: + - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1. + - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3. + - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1. + - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2. + - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1. + - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2. +``` + #### 3-Node-Haswell (3n-hsw) PROD ``` @@ -1487,7 +1753,7 @@ To be completed. - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors. - Chassis: SuperMicro SYS-7049GP-TRT. - Motherboard: SuperMicro X11DPG-QT. - - Processors: 2* Intel Platinum 8180 2.3 GHz. + - Processors: 2* Intel Platinum 8180 2.5 GHz. - RAM Memory: 16* 16GB DDR4-2666MHz. - Disks: 2* 1.6TB 6G SATA SSD. 2. Intel Atom servers with Rangely processors. -- 2.16.6