From 7a68b45126c805dc0e12dac41b810495a97bf88f Mon Sep 17 00:00:00 2001 From: Maciek Konstantynowicz Date: Wed, 9 Jan 2019 14:50:35 +0000 Subject: [PATCH] Markdown doc with FD.io CSIT physical lab design for Skx, Arm, Atom. Change-Id: Ib93c3320d213e74f67984c90a0e30bd7b2d63181 Signed-off-by: Maciek Konstantynowicz --- docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md | 1386 ++++++++++++++++++++++++++++++++ 1 file changed, 1386 insertions(+) create mode 100644 docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md diff --git a/docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md b/docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md new file mode 100644 index 0000000000..90331a0afb --- /dev/null +++ b/docs/lab/Testbeds_Xeon_Skx_Arm_Atom.md @@ -0,0 +1,1386 @@ +## FD.io CSIT testbeds - Xeon Skylake, Arm, Atom +This is a low-level design implemented as an extensions of FD.io CSIT lab to accommodate the new Intel Xeon Skylake, Arm AArch64 and Atom devices. Content has been copied from [FD.io CSIT testbeds wiki page: Xeon_skx, Arm, Atom](https://wiki.fd.io/view/CSIT/Testbeds:_Xeon_Skx,_Arm,_Atom). + +## Testbeds Overview +### Testbeds Type Breakdown +``` + #. CSIT_tb. Purpose. SUT. TG. #tb. #SUTs. #TGs. #skx_node. + 1. 1-node Xeon. func. skx. n/a. 2. 2. 0. 2. + 2. 2-node Xeon. perf. skx. skx. 4. 4. 4. 8. + 3. 3-node Xeon. perf. skx. skx. 2. 4. 2. 6. + 4. tcp-l47. tcp-stack. skx. ps1. 1. 1. 1. 1. + 5. atom-netgate. perf+func. net. skx. 1. 3. 1. 1. + 6. aarch64-d05 perf+func. arm. skx. 2. 2. 1. 1. + 7. aarch64-mcbin perf arm. skx. 1. 2. 1. 1. + Total skx_node: 20. +``` + +### 1-Node Xeon Testbeds +One 1-node Xeon testbed for VPP_Device tests is built using one SUT (Type-6 server), with NIC ports connected back-to-back. + +### 2-Node Xeon Testbeds +Four 2-node Xeon testbeds (are expected to be built|are built), with each testbed using one SUTs (Type-1 server) and one TG (Type-2 server) connected back-to-back. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections. + +### 3-Node Xeon Testbeds +Two 3-node Xeon testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-1 server) and one TG (Type-2 server) connected in full-mesh triangle. NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in next sections. + +### Arm Testbeds +One 3-node Huawei testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-3 server) and one TG (Type-2 server) connected in full-mesh triangle. + +One 3-node Marvell testbeds (are expected to be built|are built), with each testbed using two SUTs (Type-4 server) and one TG (Type-2 server) connected in full-mesh triangle. + +### TCP/IP and L47 Testbeds +One 2-node Ixia PS One and Xeon server testbed, for TCP/IP host stack tests. + +### Atom Testbeds +One 3-node Atom (Netgate based) testbed is built consisting of three SUTs (Type-5 Netgate device.) NIC cards placement into slots and NIC ports connectivity is following the testbed specification included in the next section. + +## Inventory +### Appliances +``` +1. Ixia PerfectStorm One Appliance + - 1 * PS10GE4NG + - Chassis: PS10GE4NG. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: Quad-Core, Intel Processor. + - HW accelerators: FPGA offload. + - RAM Memory: 64GB. + - Disks: 1 * 1 TB, Enterprise Class, High MTBF. + - Physical Interfaces: 4 * 10GE SFP+. + - Operating System: Native IxOS. +``` + +### Arm Servers +``` +1. Arm Cortex A-72 servers + - 2 * Huawei TaiShan 2280. + - Chassis: Huawei TaiShan 2280. + - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72. + - RAM Memory: 8* 16GB DDR4-2400MT/s. + - Disks: 1* 4TB SATA HDD. + - 3 * MACCHIATObin + - Chassis: MACCHIATObin. + - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72. + - RAM Memory: 1* 16GB DDR4. + - Disks: 1* 128GB(?) SATA SDD. +``` + +Platform Name and Specification | Role | Status | Hostname | IP | IPMI | Cores | RAM | Ethernet | Distro +------------------------------- | ---- | ------ | -------- | -- | ---- | ----- | --- | -------- | ------ +[SoftIron OverDrive 1000](https://softiron.com/development-tools/overdrive-1000/) | CI build server | Up, Not Running Jobs | softiron-1 | 10.30.51.12 | N/A | 4 | 8GB | | openSUSE + | CI build server | Up, Not Running Jobs | softiron-2 | 10.30.51.13 | N/A | 4 | 8GB | | openSUSE + | CI build server | Up, Not Running Jobs | softiron-3 | 10.30.51.14 | N/A | 4 | 8GB | | openSUSE +[Cavium ThunderX](https://cavium.com/product-thunderx-arm-processors.html) | CI build server | Up, Running VPP CI | nomad3arm | 10.30.51.38 | 10.30.50.38 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04 + | CI build server | Up, Running VPP CI | nomad4arm | 10.30.51.39 | 10.30.50.39 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04 + | CI build server | Up, Running VPP CI | nomad5arm | 10.30.51.40 | 10.30.50.40 | 96 | 128GB | 3x40GbE QSFP+ / 4x10GbE SFP+ | Ubuntu 16.04 + | CI build server | Up, Not Running Jobs, USB_NIC broken, QSFP wiring to be added | fdio-cavium4 | 10.30.51.65 | 10.30.50.65 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 18.04.1 + | VPP dev debug | Up | fdio-cavium5 | 10.30.51.66 | 10.30.50.66 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 18.04.1 + | CI build server | Up, Not Running Jobs, USB_NIC broken, QSFP wiring to be added | fdio-cavium6 | 10.30.51.67 | 10.30.50.67 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 16.04.1 + | VPP dev debug | Up | fdio-cavium7 | 10.30.51.68 | 10.30.50.68 | 96 | 256GB | 2xQSFP+ / USB Ethernet | Ubuntu 16.04.1 +Huawei TaiShan 2280 | CSIT Performance | Up, Manual perf experiments | s15-t33-sut1 | 10.30.51.36 | 10.30.50.36 | 64 | 128GB | 2x10GbE SFP+ Intel 82599 / 2x25GbE SFP28 Mellanox CX-4 | Ubuntu 17.10 + | CSIT Performance | Up, Manual perf experiments | s16-t33-sut2 | 10.30.51.37 | 10.30.50.37 | 64 | 128GB | 2x10GbE SFP+ Intel 82599 / 2x25GbE SFP28 Mellanox CX-4 | Ubuntu 17.10 +[Marvell MACCHIATObin](http://macchiatobin.net/) | CSIT Performance | Up, Manual experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | s20-t34-sut1 | 10.30.51.41 | 10.30.51.49, then connect to /dev/ttyUSB0 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.4 + | CSIT Performance | Up, Manual experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | s21-t34-sut2 | 10.30.51.42 | 10.30.51.49, then connect to /dev/ttyUSB1 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.5 + | VPP dev debug | Up, Manual VPP Device experiments, Full Skx TG too much for it - suggest to use LXC/DRC TG(!) | fdio-mcbin3 | 10.30.51.43 | 10.30.51.49, then connect to /dev/ttyUSB2 | 4 | 16GB | 2x10GbE SFP+ | Ubuntu 16.04.5 + +### Xeon and Atom Servers +``` +1. Intel Xeon servers: + - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors. + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.3 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. +2. Intel Atom servers with Rangely processors. + - 3 * Netgate XG-2758-1u + - Chassis: Netgate XG-2758-1u + - Processors: 1* Rangely (Atom) C2758 2.4 GHz + - RAM Memory: 16GB ECC + - Disks: 150 GB +``` + +### Network Interface Cards +``` +1. 10GE NICs + - 14 * Intel® Ethernet Converged Network Adapter X710-DA4 + - 6 * Intel® Ethernet Converged Network Adapter X710-DA2 + - 6 * Intel® Ethernet Converged Network Adapter X520-DA2 +2. 25GE NICs + - 12 * Intel® Ethernet Network Adapter XXV710-DA2 +3. 40GE NICs + - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2 +4. 100GE NICs + - 4 * mcx556a-edat NICs (not on site yet, in transit) +``` + +### Pluggables and Cables +Pluggables: +``` +1. 10GE SFP+ + - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics + - 80 * 10G SR optic (generic, "Intel" compatible branded) +2. 25GE SFP28 + - None +3. 40GE QSFP+ + - None +4. 100GE + - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit) +``` + +Standalone cables: +``` +1. 10GE + - None +2. 25GE + - None +3. 40GE QSFP+ + - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable +4. 100GE + - None +``` + +### Other Network Cards +Any QATs? + +## Installation Status +Lab installation status is tracked by LF IT team in [FD.io Server Status](https://docs.google.com/document/d/16TdvGC73wuNQjkP355MTXRckv7yqnaxJkWwX7G7izEo/edit?ts=5b10411b#heading=h.dprb64shku8u). + +## Server/Device Management and Naming +### Server Management Requirements +Total of 20 SM SYS-7049GP-TRT servers are made available for FD.IO CSIT testbed. +For management purposes, each server must have following two ports connected to the management network: +``` +- 1GE IPMI port + - IPMI - Intelligent Platform Management Interface. + - Required for access to embedded server management with WebUI, CLI, SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates. +- 1GE/10GE management port + - hostOS management port for general system management. +``` + +### Server and Port Naming Convention +Following naming convention is used within this page to specify physical connectivity and wiring across defined CSIT testbeds: +``` +- testbedname: testbedN. +- hostname: + - traffic-generator: tN-tgW. + - system-under-testX: tN-sutX. +- portnames: + - tN-tgW-cY/pZ. + - tN-sutX-cY/pZ. +- where: + - N - testbed number. + - tgW - server acts as traffic-generator with W index. + - sutX - server acts as system-under-test with X index. + - Y - PCIe slot number denoting a NIC card number within the host. + - Y=2,4,9 - slots connected to NUMA node 0. + - Y=6,8,10 - slots connected to NUMA node 1. + - Z - port number on the NIC card. +``` + +### Server Management - Addressing +Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a Management port, which are connected to two different VLANs. +``` +1. LOM (IPMI) VLAN: + - Subnet: 10.30.50.0/24 + - Gateway: 10.30.50.1 + - Broadcast: 10.30.50.255 + - DNS1: 199.204.44.24 + - DNS2: 199.204.47.54 +2. Management Vlan: + - Subnet: 10.30.51.0/24 + - Gateway: 10.30.51.1 + - Broadcast: 10.30.51.255 + - DNS1: 199.204.44.24 + - DNS2: 199.204.47.54 +``` +To access these hosts, an VPN connection is required. + +### LOM (IPMI) VLAN IP Addresses +.. + +### Management VLAN IP Addresses +.. + +## Testbeds Specification - Target Build +### Server/Ports Naming, NIC Placement +#### 1-Node Xeon +Each server in 1-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification: +``` +- Server1 [Type-6]: + - testbedname: testbed11. + - hostname: s1-t11-sut1. + - IPMI IP: 10.30.50.47 + - Host IP: 10.30.51.50 + - portnames: + - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE. + - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE. + - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE. + - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE. +- Server2 [Type-6]: + - testbedname: testbed12. + - hostname: s2-t12-sut1. + - IPMI IP: 10.30.50.48 + - Host IP: 10.30.51.51 + - portnames: + - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE. + - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE. + - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE. + - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE. +``` + +#### 2-Node Xeon +Each server in 2-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification: +``` +- Server3 [Type-1]: + - testbedname: testbed21. + - hostname: s3-t21-sut1. + - IPMI IP: 10.30.50.41 + - Host IP: 10.30.51.44 + - portnames: + - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s3-t21-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s3-t21-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- Server4 [Type-2]: + - testbedname: testbed21. + - hostname: s4-t21-tg1. + - IPMI IP: 10.30.50.42 + - Host IP: 10.30.51.45 + - portnames: + - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s4-t21-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s4-t21-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- Server5 [Type-1]: + - testbedname: testbed22. + - hostname: s5-t22-sut1. + - IPMI IP: 10.30.50.49 + - Host IP: 10.30.51.52 + - portnames: + - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s5-t22-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s5-t22-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- Server6 [Type-2]: + - testbedname: testbed22. + - hostname: s6-t22-tg1. + - IPMI IP: 10.30.50.50 + - Host IP: 10.30.51.53 + - portnames: + - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s6-t22-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s6-t22-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- Server7 [Type-1]: + - testbedname: testbed23. + - hostname: s7-t23-sut1. + - IPMI IP: 10.30.50.51 + - Host IP: 10.30.51.54 + - portnames: + - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s7-t23-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s7-t23-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- Server8 [Type-2]: + - testbedname: testbed23. + - hostname: s8-t23-tg1. + - IPMI IP: 10.30.50.52 + - Host IP: 10.30.51.55 + - portnames: + - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s8-t23-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s8-t23-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- Server9 [Type-1]: + - testbedname: testbed24. + - hostname: s9-t24-sut1. + - IPMI IP: 10.30.50.53 + - Host IP: 10.30.51.56 + - portnames: + - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s9-t24-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s9-t24-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- Server10 [Type-2]: + - testbedname: testbed24. + - hostname: s10-t24-tg1. + - IPMI IP: 10.30.50.54 + - Host IP: 10.30.51.57 + - portnames: + - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s10-t24-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s10-t24-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +``` + +#### 3-Node Xeon +Each server in 3-node Xeon topology has its NIC cards placed, and NIC cards and ports indexed per following specification: +``` +- Server11 [Type-1]: + - testbedname: testbed31. + - hostname: s11-t31-sut1. + - IPMI IP: 10.30.50.43 + - Host IP: 10.30.51.46 + - portnames: + - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- Server12 [Type-1]: + - testbedname: testbed31. + - hostname: s12-t31-sut2. + - IPMI IP: 10.30.50.44 + - Host IP: 10.30.51.47 + - portnames: + - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE. + - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE. + - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE. + - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE. + - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- Server13 [Type-2]: + - testbedname: testbed31. + - hostname: s13-t31-tg1. + - IPMI IP: 10.30.50.45 + - Host IP: 10.30.51.48 + - portnames: + - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- Server14 [Type-1]: + - testbedname: testbed32. + - hostname: s14-t32-sut1. + - IPMI IP: 10.30.50.55 + - Host IP: 10.30.51.58 + - portnames: + - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE. + - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- Server15 [Type-1]: + - testbedname: testbed32. + - hostname: s15-t32-sut2. + - IPMI IP: 10.30.50.56 + - Host IP: 10.30.51.59 + - portnames: + - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE. + - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE. + - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE. + - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE. + - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +- Server16 [Type-2]: + - testbedname: testbed32. + - hostname: s16-t32-tg1. + - IPMI IP: 10.30.50.57 + - Host IP: 10.30.51.60 + - portnames: + - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. + - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE. + - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE. +``` + +#### 3-Node Arm +Note: Server19 (TG) is shared between testbed33 & testbed34 +``` +- Server17 [Type-3]: + - testbedname: testbed33. + - hostname: s17-t33-sut1. + - IPMI IP: 10.30.50.36 + - Host IP: 10.30.51.36 + - portnames: + - s17-t33-sut1-ca/p1 - 10GE-port1 82599-2p10GE. + - s17-t33-sut1-ca/p2 - 10GE-port2 82599-2p10GE. + - s17-t33-sut1-c2/p1 - 25GE-port1 cx4-2p25GE. + - s17-t33-sut1-c2/p2 - 25GE-port2 cx4-2p25GE. +- Server18 [Type-3]: + - testbedname: testbed33. + - hostname: s18-t33-sut2. + - IPMI IP: 10.30.50.37 + - Host IP: 10.30.51.37 + - portnames: + - s18-t33-sut2-ca/p1 - 10GE-port1 82599-2p10GE. + - s18-t33-sut2-ca/p2 - 10GE-port2 82599-2p10GE. + - s18-t33-sut2-c2/p1 - 25GE-port1 cx4-2p25GE. + - s18-t33-sut2-c2/p2 - 25GE-port2 cx4-2p25GE. +- Server19 [Type-2]: + - testbedname: testbed33. + - hostname: s19-t33t34-tg1. + - IPMI IP: 10.30.50.46 + - Host IP: 10.30.51.49 + - portnames: + - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE. + - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE. + - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE. + - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE. + - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE. + - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE. +- Server20 [Type-4]: + - testbedname: testbed34. + - hostname: s20-t34-sut1. + - IPMI IP: N/A + - Host IP: 10.30.51.41 + - portnames: + - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell. + - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell. +- Server21 [Type-4]: + - testbedname: testbed34. + - hostname: s21-t34-sut2. + - IPMI IP: N/A + - Host IP: 10.30.51.42 + - portnames: + - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell. + - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell. +``` + +#### TCP/IP and L47 +Each server (appliance) in 2-node TCP/IP topology has its NIC cards placed, and NIC cards and ports indexed per following specification: +``` +- Server25 [Type-8]: + - testbedname: testbed25. + - hostname: s25-t25-sut1. + - IPMI IP: 10.30.50.58 + - Host IP: 10.30.51.61 + - portnames: + - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE. + - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE. + - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE. + - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE. +- Server26 [Type-7]: + - testbedname: testbed25. + - hostname: s26-t25-tg1. + - IPMI IP: 10.30.50.59 + - Host IP: 10.30.51.62 + - portnames: + - s26-t25-tg1-p1 - 10GE-port1. + - s26-t25-tg1-p2 - 10GE-port2. + - s26-t25-tg1-p3 - 10GE-port3. + - s26-t25-tg1-p4 - 10GE-port4. +``` + +#### 3-Node Atom +Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB. +``` +- Server22 [Type-5]: + - testbedname: testbed35. + - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1). + - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0 + - Host IP: 10.30.51.9 + - portnames: + - s22-t35-sut1-p1 - 10GE-port1 ix0 82599. + - s22-t35-sut1-p2 - 10GE-port2 ix1 82599. + - 1GB ports (tbd) +- Server23 [Type-5]: + - testbedname: testbed35. + - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2). + - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1 + - Host IP: 10.30.51.10 + - portnames: + - s23-t35-sut1-p1 - 10GE-port1 ix0 82599. + - s23-t35-sut1-p2 - 10GE-port2 ix1 82599. + - 1GB ports (tbd) +- Server24 [Type-5]: + - testbedname: testbed35. + - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3). + - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2 + - Host IP: 10.30.51.11 + - portnames: + - s24-t35-sut1-p1 - 10GE-port1 ix0 82599. + - s24-t35-sut1-p2 - 10GE-port2 ix1 82599. + - 1GB ports (tbd) +``` + +### Physical Connectivity within Testbeds +#### 1-Node Xeon +Two 1-Node testbeds are constructed by connecting 2 Xeon servers using below specification: +``` +- testbed11: + - ring1 10GE-ports x710-4p10GE: + - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1. + - ring2 10GE-ports x710-4p10GE: + - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2. + - ring3 10GE-ports x710-4p10GE: + - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3. + - ring4 10GE-ports x710-4p10GE: + - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3. +- testbed12: + - ring1 10GE-ports x710-4p10GE: + - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1. + - ring2 10GE-ports x710-4p10GE: + - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2. + - ring3 10GE-ports x710-4p10GE: + - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. + - ring4 10GE-ports x710-4p10GE: + - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3. +``` + +#### 2-Node Xeon +Four 2-Node testbeds are constructed by connecting 8 Xeon servers using below specification: +``` +- testbed21: + - ring1 10GE-ports x710-4p10GE on SUT: + - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1. + - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3. + - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1. + - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2. + - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s4-t21-tg1-c9/p1 to s3-t21-sut1-c9/p1. + - s3-t21-sut1-c9/p2 to s4-t21-tg1-c9/p2. + - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2. + - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4. +- testbed22: + - ring1 10GE-ports x710-4p10GE on SUT: + - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1. + - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3. + - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1. + - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2. + - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - t22-tg1-c9/p1 to s5-t22-sut1-c9/p1. + - s5-t22-sut1-c9/p2 to s6-t22-tg1-c9/p2. + - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2. + - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4. +- testbed23: + - ring1 10GE-ports x710-4p10GE on SUT: + - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1. + - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3. + - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1. + - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2. + - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s8-t23-tg1-c9/p1 to s7-t23-sut1-c9/p1. + - s7-t23-sut1-c9/p2 to s8-t23-tg1-c9/p2. + - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2. + - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4. +- testbed24: + - ring1 10GE-ports x710-4p10GE on SUT: + - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1. + - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3. + - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1. + - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2. + - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s10-t24-tg1-c9/p1 to s9-t24-sut1-c9/p1. + - s9-t24-sut1-c9/p2 to s10-t24-tg1-c9/p2. + - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2. + - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4. +``` + +#### 3-Node Xeon +Two 3-Node testbeds are constructed by connecting 6 Xeon servers using below specification: +``` +- testbed31: + - ring1 10GE-ports x710-4p10GE on SUTs: + - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1. + - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2. + - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3. + - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4. + - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1. + - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2. + - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2. + - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1. + - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2. + - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2. + - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2. + - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4. +- testbed32: + - ring1 10GE-ports x710-4p10GE on SUTs: + - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1. + - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2. + - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2. + - ring2 10GE-ports x710-4p10GE on SUT: + - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3. + - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4. + - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4. + - ring3 25GE-ports xxv710-DA2-2p25GE on SUT + - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1. + - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2. + - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2. + - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT: + - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1. + - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2. + - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2. + - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests: + - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2. + - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4. +``` + +#### 3-Node Arm +One 3-Node testbed is constructed by connecting 3 Arm servers using below specification: +``` +- testbed33: + - ring1 10GE-ports 82599-2p10GE on SUTs: + - t33t34-tg1-c2/p1 - t33-sut1-ca/p1. + - t33-sut1-ca/p2 - t33-sut2-ca/p1. + - t33-sut2-ca/p2 - t33t34-tg1-c2/p2. + - ring2 25GE-ports cx4-2p25GE on SUTs: + - t33t34-tg1-c4/p1 - t33-sut1-c2/p1. + - t33-sut1-c2/p2 - t33-sut2-c2/p1. + - t33-sut2-c2/p2 - t33t34-tg1-c4/p2. +- testbed34: + - ring1 10GE-ports Marvell on SUTs: + - t33t34-tg1-c2/p3 - t34-sut1-ca/p1. + - t34-sut1-ca/p2 - t34-sut2-ca/p1. + - t34-sut2-ca/p2 - t33t34-tg1-c2/p4. +``` + +#### TCP/IP and L47 +One 2-Node TCP/IP testbed is constructed by connecting Ixia PSOne and 1 Xeon server using below specification: +``` +- testbed25: + - link1 10GE-port x710-4p10GE on SUT: + - t25-tg1-p1 to t25-sut1-c2/p1. + - link2 10GE-port x710-4p10GE on SUT: + - t25-tg1-p2 to t25-sut1-c2/p2. + - link3 10GE-port x710-4p10GE on SUT: + - t25-tg1-p3 to t25-sut1-c2/p3. + - link4 10GE-port x710-4p10GE on SUT: + - t25-tg1-p4 to t25-sut1-c2/p4. +``` + +#### 3-Node Atom +.. + +## Server Specification +### Hardware Configuration +The new FD.io CSIT-CPL lab (is expected to contain|contains) following hardware server configurations: +``` +1. Type-1: Purpose - (Intel Xeon Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd. + - Quantity: TBD based on testbed allocation. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and 3-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.3 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel. + - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +2. Type-2: Purpose - (Intel Xeon Processor) TG for T-Rex. + - Quantity: TBD based on testbed allocation. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and 3-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.3 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel. + - PCIe Slot9 5e:00.xx: FUTURE ConnectX5-2p100GE Mellanox. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: x710-4p10GE Intel. +3. Type-3: Purpose - (Arm hip07-d05 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd. + - Quantity: 2 + - Physical connectivity: + - IPMI(?) and host management ports. + - NIC ports connected into 3-node topology. + - Main HW configuration: + - Chassis: Huawei TaiShan 2280. + - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72 + - RAM Memory: 8* 16GB DDR4-2400MT/s + - Disks: 1* 4TB SATA HDD + - NICs configuration: + - PCIe Slot2 e9:00.xx: connectx4-2p25GE Mellanox. + - PCIe Slota 11:00.xx: 82599-2p10GE Intel. +4. Type-4: Purpose - (Arm Armada 8040 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd. + - Quantity: 3 + - Physical connectivity: + - Host management ports. + - NIC ports connected into 2-node and 3-node topologies. + - Main HW configuration: + - Chassis: MACCHIATObin. + - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72 + - RAM Memory: 1* 16GB DDR4 + - Disks: 1* 128GB(?) SATA SDD + - NICs configuration: + - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP) +5. Type-5: Purpose - (Intel Atom Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd. + - Quantity: TBD based on testbed allocation. + - Physical connectivity: + - Management: serial Port (usb) for console + - NIC ports connected into 2-node. + - Main HW configuration: + - Chassis: Netgate XG-2758-1u + - Processors: 1* Rangeley (Atom) C2758 2.4 GHz + - RAM Memory: 16GB ECC + - Disks: 150 GB + - NICs configuration: + - 2x 10Gb Intel 82599ES + - 4x 1GB Intel I354 +6. Type-6: Purpose - (Intel Xeon Processor) SUT for VPP_Device functional tests. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 2-node and 3-node topologies. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.3 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: x710-4p10GE Intel. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +7. Type-7: Purpose - Ixia PerfectStorm One Appliance TG for TCP/IP performance tests. + - Quantity: 1. + - Physical connectivity: + - Host management interface: 10/100/1000-BaseT. + - 8-port 10GE SFP+ integrated NIC. + - Main HW configuration: + - Chassis: PS10GE4NG. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: Quad-Core, Intel Processor. + - HW accelerators: FPGA offload. + - RAM Memory: 64GB. + - Disks: 1 * 1 TB, Enterprise Class, High MTBF. + - Physical Interfaces: 4 * 10GE SFP+. + - Operating System: Native IxOS. + - Interface configuration: + - Port-1: 10GE SFP+. + - Port-2: 10GE SFP+. + - Port-3: 10GE SFP+. + - Port-4: 10GE SFP+. +8. Type-8: Purpose - (Intel Xeon Processor) SUT for TCP/IP host stack tests. + - Quantity: 1. + - Physical connectivity: + - IPMI and host management ports. + - NIC ports. + - Main HW configuration: + - Chassis: SuperMicro SYS-7049GP-TRT. + - Motherboard: SuperMicro X11DPG-QT. + - Processors: 2* Intel Platinum 8180 2.3 GHz. + - RAM Memory: 16* 16GB DDR4-2666MHz. + - Disks: 2* 1.6TB 6G SATA SSD. + - NICs configuration: + - Numa0: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot2 18:00.xx: x710-4p10GE Intel. + - PCIe Slot4 3b:00.xx: empty. + - PCIe Slot9 5e:00.xx: empty. + - Numa1: (x16, x16, x16 PCIe3.0 lanes) + - PCIe Slot6 86:00.xx: empty. + - PCIe Slot8 af:00.xx: empty. + - PCIe Slot10 d8:00.xx: empty. +9. Type-9: Purpose - (Cavium ThunderX2 Processor) SUT for VPP_Device functional tests. + - Quantity: 1 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports connected into 1-node topologies. + - Main HW configuration: + - Chassis: Gigabyte R181-T90 1U + - Motheboard: MT91-FS1 + - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz + - RAM Memory: 4* 32GB RDIMM + - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25 + - NICs configuration: + - PCIe Slotx : XL710-QDA2. + - PCIe Sloty : XL710-QDA2. + - PCIe Slotz : XL710-QDA2. +10. Type-10: Purpose - (Intel Atom C3000 Processor) SUT for SW Data Plane Workload i.e. VPP, testpmd. + - Quantity: 4 + - Physical connectivity: + - IPMI and host management ports. + - NIC ports. + - Main HW configuration: + - Chassis: SuperMicro SYS-E300-9A + - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz + - RAM Memory: 32GB ECC + - Disks: 480 GB + - NICs configuration: + - 2x 10Gb Intel x553 fiber ports + - 2x 10Gb Intel x553 copper ports + - 4x 1GB Intel I350 ports +``` + +### Xeon Skx Server BIOS Configuration +#### Boot Feature +``` + | Quiet Boot [Enabled] |Boot option | + | | | + | Option ROM Messages [Force BIOS] | | + | Bootup NumLock State [On] | | + | Wait For "F1" If Error [Enabled] | | + | INT19 Trap Response [Immediate] | | + | Re-try Boot [Disabled] | | + | Install Windows 7 USB support [Disabled] | | + | Port 61h Bit-4 Emulation [Disabled] | | + | | | + | Power Configuration | | + | Watch Dog Function [Disabled] | | + | Restore on AC Power Loss [Last State] | | + | Power Button Function [Instant Off] | | + | Throttle on Power Fail [Disabled] | | +``` + +#### CPU Configuration +``` + | Processor Configuration |Enables Hyper Threading | + | -------------------------------------------------- |(Software Method to | + | Processor BSP Revision 50654 - SKX H0 |Enable/Disable Logical | + | Processor Socket CPU1 | CPU2 |Processor threads. | + | Processor ID 00050654* | 000506... | | + | Processor Frequency 2.500GHz | 2.500GHz | | + | Processor Max Ratio 19H | 19H | | + | Processor Min Ratio 0AH | 0AH | | + | Microcode Revision 02000030 | | + | L1 Cache RAM 64KB | 64KB | | + | L2 Cache RAM 1024KB | 1024KB | | + | L3 Cache RAM 39424KB | 39424KB | | + | Processor 0 Version | | + | Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz | | + | Processor 1 Version | | + | Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz | | + | | | + | Hyper-Threading [ALL] [Enable] | | + | Core Disable Bitmap(Hex) 0 | | + | Execute Disable Bit [Enable] | | + | Intel Virtualization Technology [Enable] | | + | PPIN Control [Unlock/Enable] | | + | Hardware Prefetcher [Enable] | | + | Adjacent Cache Prefetch [Enable] | | + | DCU Streamer Prefetcher [Enable] | | + | DCU IP Prefetcher [Enable] | | + | LLC Prefetch [Disable] | | + | Extended APIC [Disable] | | + | AES-NI [Enable] | | + |> Advanced Power Management Configuration | | +``` + +##### Advanced Power Management Configuration +``` + | Advanced Power Management Configuration |Switch CPU Power Management | + | -------------------------------------------------- |profile | + | Power Technology [Custom] | | + | Power Performance Tuning [BIOS Controls EPB] | | + | ENERGY_PERF_BIAS_CFG mode [Maximum Performance] | | + |> CPU P State Control | | + |> Hardware PM State Control | | + |> CPU C State Control | | + |> Package C State Control | | + |> CPU T State Control | | +``` + +###### CPU P State Control +``` + | CPU P State Control |Enable/Disable EIST | + | |(P-States) | + | SpeedStep (Pstates) [Disable] | | + | EIST PSD Function [HW_ALL] | | +``` + +###### Hardware PM State Control +``` + | Hardware PM State Control |Disable: Hardware chooses a | + | |P-state based on OS Request | + | Hardware P-States [Disable] |(Legacy P-States) | + | |Native Mode:Hardware | + | |chooses a P-state based on | + | |OS guidance | + | |Out of Band Mode:Hardware | + | |autonomously chooses a | + | |P-state (no OS guidance) | +``` + +###### CPU C State Control +``` + | CPU C State Control |Autonomous Core C-State | + | |Control | + | Autonomous Core C-State [Disable] | | + | CPU C6 report [Disable] | | + | Enhanced Halt State (C1E) [Disable] | | +``` + +###### Package C State Control +``` + | Package C State Control |Package C State limit | + | | | + | Package C State [C0/C1 state] | | +``` + +###### CPU T State Control +``` + | CPU T State Control |Enable/Disable Software | + | |Controlled T-States | + | Software Controlled T-States [Disable] | | +``` + +##### Chipset Configuration +``` + | WARNING: Setting wrong values in below sections may cause |North Bridge Parameters | + | system to malfunction. | | + |> North Bridge | | + |> South Bridge | | +``` + +###### North Bridge +``` + |> UPI Configuration |Displays and provides | + |> Memory Configuration |option to change the UPI | + |> IIO Configuration |Settings | +``` + +###### UPI Configuration +``` + | UPI Configuration |Choose Topology Precedence | + | -------------------------------------------------- |to degrade features if | + | Number of CPU 2 |system options are in | + | Number of Active UPI Link 3 |conflict or choose Feature | + | Current UPI Link Speed Fast |Precedence to degrade | + | Current UPI Link Frequency 10.4 GT/s |topology if system options | + | UPI Global MMIO Low Base / Limit 90000000 / FBFFFFFF |are in conflict. | + | UPI Global MMIO High Base / Limit 0000000000000000 / ... | | + | UPI Pci-e Configuration Base / Size 80000000 / 10000000 | | + | Degrade Precedence [Topology Precedence] | | + | Link L0p Enable [Disable] | | + | Link L1 Enable [Disable] | | + | IO Directory Cache (IODC) [Auto] | | + | SNC [Disable] | | + | XPT Prefetch [Disable] | | + | KTI Prefetch [Enable] | | + | Local/Remote Threshold [Auto] | | + | Stale AtoS [Disable] | | + | LLC dead line alloc [Enable] | | + | Isoc Mode [Auto] | | +``` + +###### Memory Configuration +``` + | |POR - Enforces Plan Of | + | -------------------------------------------------- |Record restrictions for | + | Integrated Memory Controller (iMC) |DDR4 frequency and voltage | + | -------------------------------------------------- |programming. Disable - | + | |Disables this feature. | + | Enforce POR [Disable] | | + | Memory Frequency [2666] | | + | Data Scrambling for NVMDIMM [Auto] | | + | Data Scrambling for DDR4 [Auto] | | + | tCCD_L Relaxation [Auto] | | + | Memory tRWSR Relaxation [Enable] | | + | 2X REFRESH [Auto] | | + | Page Policy [Auto] | | + | IMC Interleaving [2-way Interleave] | | + |> Memory Topology | | + |> Memory RAS Configuration | | +``` + +###### IIO Configuration +``` + | IIO Configuration |Expose IIO DFX devices and | + | -------------------------------------------------- |other CPU devices like PMON | + | | | + | EV DFX Features [Disable] | | + |> CPU1 Configuration | | + |> CPU2 Configuration | | + |> IOAT Configuration | | + |> Intel. VT for Directed I/O (VT-d) | | + |> Intel. VMD technology | | + | | | + | IIO-PCIE Express Global Options | | + | ======================================== | | + | PCI-E Completion Timeout Disable [No] | | +``` + +###### CPU1 Configuration +``` + | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port | + | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected | + | IOU2 (IIO PCIe Br3) [Auto] |slot(s) | + |> CPU1 SLOT2 PCI-E 3.0 X16 | | + |> CPU1 SLOT4 PCI-E 3.0 X16 | | + |> CPU1 SLOT9 PCI-E 3.0 X16 | | +``` + +###### CPU2 Configuration +``` + | IOU0 (IIO PCIe Br1) [Auto] |Selects PCIe port | + | IOU1 (IIO PCIe Br2) [Auto] |Bifurcation for selected | + | IOU2 (IIO PCIe Br3) [Auto] |slot(s) | + |> CPU2 SLOT6 PCI-E 3.0 X16 | | + |> CPU2 SLOT8 PCI-E 3.0 X16 | | + |> CPU2 SLOT10 PCI-E 3.0 X16 | | +``` + +##### South Bridge +``` + | |Enables Legacy USB support. | + | USB Module Version 17 |AUTO option disables legacy | + | |support if no USB devices | + | USB Devices: |are connected. DISABLE | + | 1 Keyboard, 1 Mouse, 1 Hub |option will keep USB | + | |devices available only for | + | Legacy USB Support [Enabled] |EFI applications. | + | XHCI Hand-off [Disabled] | | + | Port 60/64 Emulation [Enabled] | | + | PCIe PLL SSC [Disable] | | + | Real USB Wake Up [Enabled] | | + | Front USB Wake Up [Enabled] | | + | | | + | Azalia [Auto] | | + | Azalia PME Enable [Disabled] | | +``` + +#### PCIe/PCI/PnP Configuration +``` + | PCI Bus Driver Version A5.01.12 |Enables or Disables 64bit | + | |capable Devices to be | + | PCI Devices Common Settings: |Decoded in Above 4G Address | + | Above 4G Decoding [Enabled] |Space (Only if System | + | SR-IOV Support [Enabled] |Supports 64 bit PCI | + | MMIO High Base [56T] |Decoding). | + | MMIO High Granularity Size [256G] | | + | Maximum Read Request [Auto] | | + | MMCFG Base [2G] | | + | NVMe Firmware Source [Vendor Defined Fi...] | | + | VGA Priority [Onboard] | | + | CPU1 SLOT2 PCI-E 3.0 X16 OPROM [Legacy] | | + | CPU1 SLOT4 PCI-E 3.0 X16 OPROM [Legacy] | | + | CPU2 SLOT6 PCI-E 3.0 X16 OPROM [Legacy] | | + | CPU2 SLOT8 PCI-E 3.0 X16 OPROM [Legacy] | | + | CPU1 SLOT9 PCI-E 3.0 X16 OPROM [Legacy] | | + | CPU2 SLOT10 PCI-E 3.0 X16 OPROM [Legacy] | | + | CPU2 SLOT11 PCI-E 3.0 X4(IN X8) OPROM [Legacy] | | + | M.2 CONNECTOR OPROM [Legacy] | | + | Onboard LAN1 Option ROM [Legacy] | | + | Onboard LAN2 Option ROM [Disabled] | | + | Onboard Video Option ROM [Legacy] | | + |> Network Stack Configuration | | +``` + +#### ACPI Settings +``` + | ACPI Settings |Enable or Disable Non | + | |uniform Memory Access | + | NUMA [Enabled] |(NUMA). | + | WHEA Support [Enabled] | | + | High Precision Event Timer [Enabled] | | + | ACPI Sleep State [S3 (Suspend to RAM)] | | +``` + +#### DMIDECODE +``` + # dmidecode 3.1 + Getting SMBIOS data from sysfs. + SMBIOS 3.1.1 present. + Table at 0x000E89C0. + + Handle 0x0000, DMI type 0, 26 bytes + BIOS Information + Vendor: American Megatrends Inc. + Version: 2.0 + Release Date: 11/29/2017 + Address: 0xF0000 + Runtime Size: 64 kB + ROM Size: 64 MB + Characteristics: + PCI is supported + BIOS is upgradeable + BIOS shadowing is allowed + Boot from CD is supported + Selectable boot is supported + BIOS ROM is socketed + EDD is supported + 5.25"/1.2 MB floppy services are supported (int 13h) + 3.5"/720 kB floppy services are supported (int 13h) + 3.5"/2.88 MB floppy services are supported (int 13h) + Print screen service is supported (int 5h) + Serial services are supported (int 14h) + Printer services are supported (int 17h) + ACPI is supported + USB legacy is supported + BIOS boot specification is supported + Targeted content distribution is supported + UEFI is supported + BIOS Revision: 5.12 + + Handle 0x0001, DMI type 1, 27 bytes + System Information + Manufacturer: Supermicro + Product Name: SYS-7049GP-TRT + Version: 0123456789 + Serial Number: S291427X8332242 + UUID: 00000000-0000-0000-0000-AC1F6B8A8DB6 + Wake-up Type: Power Switch + SKU Number: To be filled by O.E.M. + Family: To be filled by O.E.M. + + Handle 0x0002, DMI type 2, 15 bytes + Base Board Information + Manufacturer: Supermicro + Product Name: X11DPG-QT + Version: 1.02 + Serial Number: VM183S014930 + Asset Tag: To be filled by O.E.M. + Features: + Board is a hosting board + Board is replaceable + Location In Chassis: To be filled by O.E.M. + Chassis Handle: 0x0003 + Type: Motherboard + Contained Object Handles: 0 + + Handle 0x0003, DMI type 3, 22 bytes + Chassis Information + Manufacturer: Supermicro + Type: Other + Lock: Not Present + Version: 0123456789 + Serial Number: C7470KH06A20167 + Asset Tag: To be filled by O.E.M. + Boot-up State: Safe + Power Supply State: Safe + Thermal State: Safe + Security Status: None + OEM Information: 0x00000000 + + Handle 0x0050, DMI type 4, 48 bytes + Processor Information + Socket Designation: CPU1 + Type: Central Processor + Family: Xeon + Manufacturer: Intel(R) Corporation + ID: 54 06 05 00 FF FB EB BF + Signature: Type 0, Family 6, Model 85, Stepping 4 + Flags: + FPU (Floating-point unit on-chip) + VME (Virtual mode extension) + DE (Debugging extension) + PSE (Page size extension) + TSC (Time stamp counter) + MSR (Model specific registers) + PAE (Physical address extension) + MCE (Machine check exception) + CX8 (CMPXCHG8 instruction supported) + APIC (On-chip APIC hardware supported) + SEP (Fast system call) + MTRR (Memory type range registers) + PGE (Page global enable) + MCA (Machine check architecture) + CMOV (Conditional move instruction supported) + PAT (Page attribute table) + PSE-36 (36-bit page size extension) + CLFSH (CLFLUSH instruction supported) + DS (Debug store) + ACPI (ACPI supported) + MMX (MMX technology supported) + FXSR (FXSAVE and FXSTOR instructions supported) + SSE (Streaming SIMD extensions) + SSE2 (Streaming SIMD extensions 2) + SS (Self-snoop) + HTT (Multi-threading) + TM (Thermal monitor supported) + PBE (Pending break enabled) + Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz + Voltage: 1.6 V + External Clock: 100 MHz + Max Speed: 4000 MHz + Current Speed: 2500 MHz + Status: Populated, Enabled + Upgrade: Other + L1 Cache Handle: 0x004D + L2 Cache Handle: 0x004E + L3 Cache Handle: 0x004F + Serial Number: Not Specified + Asset Tag: UNKNOWN + Part Number: Not Specified + Core Count: 28 + Core Enabled: 28 + Thread Count: 56 + Characteristics: + 64-bit capable + Multi-Core + Hardware Thread + Execute Protection + Enhanced Virtualization + Power/Performance Control + + + Handle 0x0054, DMI type 4, 48 bytes + Processor Information + Socket Designation: CPU2 + Type: Central Processor + Family: Xeon + Manufacturer: Intel(R) Corporation + ID: 54 06 05 00 FF FB EB BF + Signature: Type 0, Family 6, Model 85, Stepping 4 + Flags: + FPU (Floating-point unit on-chip) + VME (Virtual mode extension) + DE (Debugging extension) + PSE (Page size extension) + TSC (Time stamp counter) + MSR (Model specific registers) + PAE (Physical address extension) + MCE (Machine check exception) + CX8 (CMPXCHG8 instruction supported) + APIC (On-chip APIC hardware supported) + SEP (Fast system call) + MTRR (Memory type range registers) + PGE (Page global enable) + MCA (Machine check architecture) + CMOV (Conditional move instruction supported) + PAT (Page attribute table) + PSE-36 (36-bit page size extension) + CLFSH (CLFLUSH instruction supported) + DS (Debug store) + ACPI (ACPI supported) + MMX (MMX technology supported) + FXSR (FXSAVE and FXSTOR instructions supported) + SSE (Streaming SIMD extensions) + SSE2 (Streaming SIMD extensions 2) + SS (Self-snoop) + HTT (Multi-threading) + TM (Thermal monitor supported) + PBE (Pending break enabled) + Version: Intel(R) Xeon(R) Platinum 8180 CPU @ 2.50GHz + Voltage: 1.6 V + External Clock: 100 MHz + Max Speed: 4000 MHz + Current Speed: 2500 MHz + Status: Populated, Enabled + Upgrade: Other + L1 Cache Handle: 0x0051 + L2 Cache Handle: 0x0052 + L3 Cache Handle: 0x0053 + Serial Number: Not Specified + Asset Tag: UNKNOWN + Part Number: Not Specified + Core Count: 28 + Core Enabled: 28 + Thread Count: 56 + Characteristics: + 64-bit capable + Multi-Core + Hardware Thread + Execute Protection + Enhanced Virtualization + Power/Performance Control +``` + +### Xeon Skx Server Firmware Inventory +``` +Host. IPMI IP. BIOS. CPLD. Aptio SU. CPU Microcode. PCI Bus. ME Operation FW. X710 Firmware. XXV710 Firmware. i40e. +s1-t11-sut1. 10.30.50.47. 2.1. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s2-t12-sut1. 10.30.50.48. 2.1. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s3-t21-sut1. 10.30.50.41. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s4-t21-tg1. 10.30.50.42. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s5-t22-sut1. 10.30.50.49. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s6-t22-tg1. 10.30.50.50. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s7-t23-sut1. 10.30.50.51. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s8-t23-tg1. 10.30.50.52. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s9-t24-sut1. 10.30.50.53. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s10-t24-tg1. 10.30.50.54. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s11-t31-sut1. 10.30.50.43. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s12-t31-sut2. 10.30.50.44. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s13-t31-tg1. 10.30.50.45. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s14-t32-sut1. 10.30.50.55. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s15-t32-sut2. 10.30.50.56. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s16-t32-tg1. 10.30.50.57. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +s19-t33t34-tg1. 10.30.50.46. 2.0b. 03.B1.03. 2.19.1268. 02000043. A5.01.12. 4.0.4.294. 6.01 0x80003554 1.1747.0. 6.01 0x80003554 1.1747.0. 2.1.14-k. +``` -- 2.16.6