@@ -35,12 +35,6 @@ NICs. These adapters are also referred to as vNICs below. If you are running
 or would like to run DPDK software applications on Cisco UCS servers using
 Cisco VIC adapters the following documentation is relevant.
 
-Version Information
--------------------
-
-The version of the ENIC PMD driver is 1.0.0.6 and will be printed by ENIC PMD
-during the initialization.
-
 How to obtain ENIC PMD integrated DPDK
 --------------------------------------
 
@@ -65,11 +59,31 @@ Configuration information
 
   - **Number of Queues**
 
-    The maximum number of receive and transmit queues are configurable on a per
-    vNIC basis through the Cisco UCS Manager (CIMC or UCSM). These values
-    should be configured to be greater than or equal to the nb_rx_q and nb_tx_q
-    parameters expected to  used in the call to the rte_eth_dev_configure()
-    function.
+    The maximum number of receive queues (RQs), work queues (WQs) and
+    completion queues (CQs) are configurable on a per vNIC basis
+    through the Cisco UCS Manager (CIMC or UCSM).
+
+    These values should be configured as follows:
+
+    - The number of WQs should be greater or equal to the value of the
+      expected nb_tx_q parameter in the call to the
+      rte_eth_dev_configure()
+
+    - The number of RQs configured in the vNIC should be greater or
+      equal to *twice* the value of the expected nb_rx_q parameter in
+      the call to rte_eth_dev_configure().  With the addition of Rx
+      scatter, a pair of RQs on the vnic is needed for each receive
+      queue used by DPDK, even if Rx scatter is not being used.
+      Having a vNIC with only 1 RQ is not a valid configuration, and
+      will fail with an error message.
+
+    - The number of CQs should set so that there is one CQ for each
+      WQ, and one CQ for each pair of RQs.
+
+    For example: If the application requires 3 Rx queues, and 3 Tx
+    queues, the vNIC should be configured to have at least 3 WQs, 6
+    RQs (3 pairs), and 6 CQs (3 for use by WQs + 3 for use by the 3
+    pairs of RQs).
 
   - **Size of Queues**
 
@@ -77,12 +91,197 @@ Configuration information
     a per vNIC bases via the UCS Manager and should be greater than or equal to
     the nb_rx_desc and   nb_tx_desc parameters expected to be used in the calls
     to rte_eth_rx_queue_setup() and rte_eth_tx_queue_setup() respectively.
+    An application requesting more than the set size will be limited to that
+    size.
+
+    Unless there is a lack of resources due to creating many vNICs, it
+    is recommended that the WQ and RQ sizes be set to the maximum.  This
+    gives the application the greatest amount of flexibility in its
+    queue configuration.
+
+    - *Note*: Since the introduction of Rx scatter, for performance
+      reasons, this PMD uses two RQs on the vNIC per receive queue in
+      DPDK.  One RQ holds descriptors for the start of a packet the
+      second RQ holds the descriptors for the rest of the fragments of
+      a packet.  This means that the nb_rx_desc parameter to
+      rte_eth_rx_queue_setup() can be a greater than 4096.  The exact
+      amount will depend on the size of the mbufs being used for
+      receives, and the MTU size.
+
+      For example: If the mbuf size is 2048, and the MTU is 9000, then
+      receiving a full size packet will take 5 descriptors, 1 from the
+      start of packet queue, and 4 from the second queue.  Assuming
+      that the RQ size was set to the maximum of 4096, then the
+      application can specify up to 1024 + 4096 as the nb_rx_desc
+      parameter to rte_eth_rx_queue_setup().
 
   - **Interrupts**
 
     Only one interrupt per vNIC interface should be configured in the UCS
     manager regardless of the number receive/transmit queues. The ENIC PMD
-    uses this interrupt to   get information about errors in the fast path.
+    uses this interrupt to get information about link status and errors
+    in the fast path.
+
+.. _enic-flow-director:
+
+Flow director support
+---------------------
+
+Advanced filtering support was added to 1300 series VIC firmware starting
+with version 2.0.13 for C-series UCS servers and version 3.1.2 for UCSM
+managed blade servers. In order to enable advanced filtering the 'Advanced
+filter' radio button should be enabled via CIMC or UCSM followed by a reboot
+of the server.
+
+With advanced filters, perfect matching of all fields of IPv4, IPv6 headers
+as well as TCP, UDP and SCTP L4 headers is available through flow director.
+Masking of these fields for partial match is also supported.
+
+Without advanced filter support, the flow director is limited to IPv4
+perfect filtering of the 5-tuple with no masking of fields supported.
+
+SR-IOV mode utilization
+-----------------------
+
+UCS blade servers configured with dynamic vNIC connection policies in UCS
+manager are capable of supporting assigned devices on virtual machines (VMs)
+through a KVM hypervisor. Assigned devices, also known as 'passthrough'
+devices, are SR-IOV virtual functions (VFs) on the host which are exposed
+to VM instances.
+
+The Cisco Virtual Machine Fabric Extender (VM-FEX) gives the VM a dedicated
+interface on the Fabric Interconnect (FI). Layer 2 switching is done at
+the FI. This may eliminate the requirement for software switching on the
+host to route intra-host VM traffic.
+
+Please refer to `Creating a Dynamic vNIC Connection Policy
+<http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/vm_fex/vmware/gui/config_guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide_chapter_010.html#task_433E01651F69464783A68E66DA8A47A5>`_
+for information on configuring SR-IOV Adapter policies using UCS manager.
+
+Once the policies are in place and the host OS is rebooted, VFs should be
+visible on the host, E.g.:
+
+.. code-block:: console
+
+     # lspci | grep Cisco | grep Ethernet
+     0d:00.0 Ethernet controller: Cisco Systems Inc VIC Ethernet NIC (rev a2)
+     0d:00.1 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+     0d:00.2 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+     0d:00.3 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+     0d:00.4 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+     0d:00.5 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+     0d:00.6 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+     0d:00.7 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+
+Enable Intel IOMMU on the host and install KVM and libvirt. A VM instance should
+be created with an assigned device. When using libvirt, this configuration can
+be done within the domain (i.e. VM) config file. For example this entry maps
+host VF 0d:00:01 into the VM.
+
+.. code-block:: console
+
+    <interface type='hostdev' managed='yes'>
+      <mac address='52:54:00:ac:ff:b6'/>
+      <source>
+        <address type='pci' domain='0x0000' bus='0x0d' slot='0x00' function='0x1'/>
+      </source>
+
+Alternatively, the configuration can be done in a separate file using the
+``network`` keyword. These methods are described in the libvirt documentation for
+`Network XML format <https://libvirt.org/formatnetwork.html>`_.
+
+When the VM instance is started, the ENIC KVM driver will bind the host VF to
+vfio, complete provisioning on the FI and bring up the link.
+
+.. note::
+
+    It is not possible to use a VF directly from the host because it is not
+    fully provisioned until the hypervisor brings up the VM that it is assigned
+    to.
+
+In the VM instance, the VF will now be visible. E.g., here the VF 00:04.0 is
+seen on the VM instance and should be available for binding to a DPDK.
+
+.. code-block:: console
+
+     # lspci | grep Ether
+     00:04.0 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
+
+Follow the normal DPDK install procedure, binding the VF to either ``igb_uio``
+or ``vfio`` in non-IOMMU mode.
+
+Please see :ref:`Limitations <enic_limitations>` for limitations in
+the use of SR-IOV.
+
+.. _enic-genic-flow-api:
+
+Generic Flow API support
+------------------------
+
+Generic Flow API is supported. The baseline support is:
+
+- **1200 series VICs**
+
+  5-tuple exact Flow support for 1200 series adapters. This allows:
+
+  - Attributes: ingress
+  - Items: ipv4, ipv6, udp, tcp (must exactly match src/dst IP
+    addresses and ports and all must be specified).
+  - Actions: queue and void
+  - Selectors: 'is'
+
+- **1300 series VICS with Advanced filters disabled**
+
+  With advanced filters disabled, an IPv4 or IPv6 item must be specified
+  in the pattern.
+
+  - Attributes: ingress
+  - Items: eth, ipv4, ipv6, udp, tcp, vxlan, inner eth, ipv4, ipv6, udp, tcp
+  - Actions: queue and void
+  - Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
+  - In total, up to 64 bytes of mask is allowed across all haeders
+
+- **1300 series VICS with Advanced filters enabled**
+
+  - Attributes: ingress
+  - Items: eth, ipv4, ipv6, udp, tcp, vxlan, inner eth, ipv4, ipv6, udp, tcp
+  - Actions: queue, mark, flag and void
+  - Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
+  - In total, up to 64 bytes of mask is allowed across all haeders
+
+More features may be added in future firmware and new versions of the VIC.
+Please refer to the release notes.
+
+Ingress VLAN Rewrite
+--------------------
+
+VIC adapters can tag, untag, or modify the VLAN headers of ingress
+packets. The ingress VLAN rewrite mode controls this behavior. By
+default, it is set to pass-through, where the NIC does not modify the
+VLAN header in any way so that the application can see the original
+header. This mode is sufficient for many applications, but may not be
+suitable for others. Such applications may change the mode by setting
+``devargs`` parameter ``ig-vlan-rewrite`` to one of the following.
+
+- ``pass``: Pass-through mode. The NIC does not modify the VLAN
+  header. This is the default mode.
+
+- ``priority``: Priority-tag default VLAN mode. If the ingress packet
+  is tagged with the default VLAN, the NIC replaces its VLAN header
+  with the priority tag (VLAN ID 0).
+
+- ``trunk``: Default trunk mode. The NIC tags untagged ingress packets
+  with the default VLAN. Tagged ingress packets are not modified. To
+  the application, every packet appears as tagged.
+
+- ``untag``: Untag default VLAN mode. If the ingress packet is tagged
+  with the default VLAN, the NIC removes or untags its VLAN header so
+  that the application sees an untagged packet. As a result, the
+  default VLAN becomes `untagged`. This mode can be useful for
+  applications such as OVS-DPDK performance benchmarks that utilize
+  only the default VLAN and want to see only untagged packets.
+
+.. _enic_limitations:
 
 Limitations
 -----------
@@ -97,9 +296,10 @@ Limitations
   In test setups where an Ethernet port of a Cisco adapter in TRUNK mode is
   connected point-to-point to another adapter port or connected though a router
   instead of a switch, all ingress packets will be VLAN tagged. Programs such
-  as l3fwd which do not account for VLAN tags in packets will misbehave. The
-  solution is to enable VLAN stripping on ingress. The follow code fragment is
-  example of how to accomplish this:
+  as l3fwd may not account for VLAN tags in packets and may misbehave. One
+  solution is to enable VLAN stripping on ingress so the VLAN tag is removed
+  from the packet and put into the mbuf->vlan_tci field. Here is an example
+  of how to accomplish this:
 
 .. code-block:: console
 
@@ -107,12 +307,57 @@ Limitations
      vlan_offload |= ETH_VLAN_STRIP_OFFLOAD;
      rte_eth_dev_set_vlan_offload(port, vlan_offload);
 
-How to build the suite?
------------------------
+Another alternative is modify the adapter's ingress VLAN rewrite mode so that
+packets with the default VLAN tag are stripped by the adapter and presented to
+DPDK as untagged packets. In this case mbuf->vlan_tci and the PKT_RX_VLAN and
+PKT_RX_VLAN_STRIPPED mbuf flags would not be set. This mode is enabled with the
+``devargs`` parameter ``ig-vlan-rewrite=untag``. For example::
+
+    -w 12:00.0,ig-vlan-rewrite=untag
+
+- Limited flow director support on 1200 series and 1300 series Cisco VIC
+  adapters with old firmware. Please see :ref:`enic-flow-director`.
+
+- Flow director features are not supported on generation 1 Cisco VIC adapters
+  (M81KR and P81E)
+
+- **SR-IOV**
+
+  - KVM hypervisor support only. VMware has not been tested.
+  - Requires VM-FEX, and so is only available on UCS managed servers connected
+    to Fabric Interconnects. It is not on standalone C-Series servers.
+  - VF devices are not usable directly from the host. They can  only be used
+    as assigned devices on VM instances.
+  - Currently, unbind of the ENIC kernel mode driver 'enic.ko' on the VM
+    instance may hang. As a workaround, enic.ko should blacklisted or removed
+    from the boot process.
+  - pci_generic cannot be used as the uio module in the VM. igb_uio or
+    vfio in non-IOMMU mode can be used.
+  - The number of RQs in UCSM dynamic vNIC configurations must be at least 2.
+  - The number of SR-IOV devices is limited to 256. Components on target system
+    might limit this number to fewer than 256.
+
+- **Flow API**
+
+  - The number of filters that can be specified with the Generic Flow API is
+    dependent on how many header fields are being masked. Use 'flow create' in
+    a loop to determine how many filters your VIC will support (not more than
+    1000 for 1300 series VICs). Filter are checked for matching in the order they
+    were added. Since there currently is no grouping or priority support,
+    'catch-all' filters should be added last.
+
+How to build the suite
+----------------------
+
 The build instructions for the DPDK suite should be followed. By default
 the ENIC PMD library will be built into the DPDK library.
 
-For configuring and using UIO and VFIO frameworks, please refer the
+Refer to the document :ref:`compiling and testing a PMD for a NIC
+<pmd_build_and_test>` for details.
+
+By default the ENIC PMD library will be built into the DPDK library.
+
+For configuring and using UIO and VFIO frameworks, please refer to the
 documentation that comes with DPDK suite.
 
 Supported Cisco VIC adapters
@@ -132,16 +377,15 @@ ENIC PMD supports all recent generations of Cisco VIC adapters including:
 - VIC 1385
 - VIC 1387
 
-- Flow director features are not supported on generation 1 Cisco VIC adapters
-   (M81KR and P81E)
-
 Supported Operating Systems
 ---------------------------
+
 Any Linux distribution fulfilling the conditions described in Dependencies
 section of DPDK documentation.
 
 Supported features
 ------------------
+
 - Unicast, multicast and broadcast transmission and reception
 - Receive queue polling
 - Port Hardware Statistics
@@ -149,25 +393,31 @@ Supported features
 - IP checksum offload
 - Receive side VLAN stripping
 - Multiple receive and transmit queues
-- Flow Director ADD, UPDATE, DELETE, STATS operation support for IPV4 5-TUPLE
-  flows
+- Flow Director ADD, UPDATE, DELETE, STATS operation support IPv4 and IPv6
 - Promiscuous mode
 - Setting RX VLAN (supported via UCSM/CIMC only)
 - VLAN filtering (supported via UCSM/CIMC only)
 - Execution of application by unprivileged system users
 - IPV4, IPV6 and TCP RSS hashing
+- Scattered Rx
+- MTU update
+- SR-IOV on UCS managed servers connected to Fabric Interconnects.
+- Flow API
 
-Known bugs and Unsupported features in this release
+Known bugs and unsupported features in this release
 ---------------------------------------------------
+
 - Signature or flex byte based flow direction
 - Drop feature of flow direction
 - VLAN based flow direction
 - non-IPV4 flow direction
 - Setting of extended VLAN
 - UDP RSS hashing
+- MTU update only works if Scattered Rx mode is disabled
 
 Prerequisites
 -------------
+
 - Prepare the system as recommended by DPDK suite.  This includes environment
   variables, hugepages configuration, tool-chains and configuration
 - Insert vfio-pci kernel module using the command 'modprobe vfio-pci' if the
@@ -177,13 +427,12 @@ Prerequisites
 - DPDK suite should be configured based on the user's decision to use VFIO or
   UIO framework
 - If the vNIC device(s) to be used is bound to the kernel mode Ethernet driver
-  (enic), use 'ifconfig' to bring the interface down. The dpdk_nic_bind.py tool
-  can then be used to unbind the device's bus id from the enic kernel mode
-  driver.
+  use 'ifconfig' to bring the interface down. The dpdk-devbind.py tool can
+  then be used to unbind the device's bus id from the ENIC kernel mode driver.
 - Bind the intended vNIC to vfio-pci in case the user wants ENIC PMD to use
-  VFIO framework using dpdk_nic_bind.py.
+  VFIO framework using dpdk-devbind.py.
 - Bind the intended vNIC to igb_uio in case the user wants ENIC PMD to use
-  UIO framework using dpdk_nic_bind.py.
+  UIO framework using dpdk-devbind.py.
 
 At this point the system should be ready to run DPDK applications. Once the
 application runs to completion, the vNIC can be detached from vfio-pci or
@@ -210,10 +459,12 @@ libraries and the initialization time of the application.
 
 Additional Reference
 --------------------
+
 - http://www.cisco.com/c/en/us/products/servers-unified-computing
 
 Contact Information
 -------------------
+
 Any questions or bugs should be reported to DPDK community and to the ENIC PMD
 maintainers: