Imported Upstream version 17.05
[deb_dpdk.git] / doc / guides / nics / liquidio.rst
diff --git a/doc/guides/nics/liquidio.rst b/doc/guides/nics/liquidio.rst
new file mode 100644 (file)
index 0000000..f04cb16
--- /dev/null
@@ -0,0 +1,223 @@
+..  BSD LICENSE
+    Copyright(c) 2017 Cavium, Inc.. All rights reserved.
+    All rights reserved.
+
+    Redistribution and use in source and binary forms, with or without
+    modification, are permitted provided that the following conditions
+    are met:
+
+    * Redistributions of source code must retain the above copyright
+    notice, this list of conditions and the following disclaimer.
+    * Redistributions in binary form must reproduce the above copyright
+    notice, this list of conditions and the following disclaimer in
+    the documentation and/or other materials provided with the
+    distribution.
+    * Neither the name of Cavium, Inc. nor the names of its
+    contributors may be used to endorse or promote products derived
+    from this software without specific prior written permission.
+
+    THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
+    "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
+    LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
+    A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
+    OWNER(S) OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
+    SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
+    LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
+    DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
+    THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
+    (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
+    OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
+
+LiquidIO VF Poll Mode Driver
+============================
+
+The LiquidIO VF PMD library (librte_pmd_lio) provides poll mode driver support for
+Cavium LiquidIO® II server adapter VFs. PF management and VF creation can be
+done using kernel driver.
+
+More information can be found at `Cavium Official Website
+<http://cavium.com/LiquidIO_Adapters.html>`_.
+
+Supported LiquidIO Adapters
+-----------------------------
+
+- LiquidIO II CN2350 210SV/225SV
+- LiquidIO II CN2360 210SV/225SV
+
+
+Pre-Installation Configuration
+------------------------------
+
+The following options can be modified in the ``config`` file.
+Please note that enabling debugging options may affect system performance.
+
+- ``CONFIG_RTE_LIBRTE_LIO_PMD`` (default ``y``)
+
+  Toggle compilation of LiquidIO PMD.
+
+- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_DRIVER`` (default ``n``)
+
+  Toggle display of generic debugging messages.
+
+- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_INIT`` (default ``n``)
+
+  Toggle display of initialization related messages.
+
+- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_RX`` (default ``n``)
+
+  Toggle display of receive fast path run-time messages.
+
+- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_TX`` (default ``n``)
+
+  Toggle display of transmit fast path run-time messages.
+
+- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_MBOX`` (default ``n``)
+
+  Toggle display of mailbox messages.
+
+- ``CONFIG_RTE_LIBRTE_LIO_DEBUG_REGS`` (default ``n``)
+
+  Toggle display of register reads and writes.
+
+
+SR-IOV: Prerequisites and Sample Application Notes
+--------------------------------------------------
+
+This section provides instructions to configure SR-IOV with Linux OS.
+
+#. Verify SR-IOV and ARI capabilities are enabled on the adapter using ``lspci``:
+
+   .. code-block:: console
+
+      lspci -s <slot> -vvv
+
+   Example output:
+
+   .. code-block:: console
+
+      [...]
+      Capabilities: [148 v1] Alternative Routing-ID Interpretation (ARI)
+      [...]
+      Capabilities: [178 v1] Single Root I/O Virtualization (SR-IOV)
+      [...]
+      Kernel driver in use: LiquidIO
+
+#. Load the kernel module:
+
+   .. code-block:: console
+
+      modprobe liquidio
+
+#. Bring up the PF ports:
+
+   .. code-block:: console
+
+      ifconfig p4p1 up
+      ifconfig p4p2 up
+
+#. Change PF MTU if required:
+
+   .. code-block:: console
+
+      ifconfig p4p1 mtu 9000
+      ifconfig p4p2 mtu 9000
+
+#. Create VF device(s):
+
+   Echo number of VFs to be created into ``"sriov_numvfs"`` sysfs entry
+   of the parent PF.
+
+   .. code-block:: console
+
+      echo 1 > /sys/bus/pci/devices/0000:03:00.0/sriov_numvfs
+      echo 1 > /sys/bus/pci/devices/0000:03:00.1/sriov_numvfs
+
+#. Assign VF MAC address:
+
+   Assign MAC address to the VF using iproute2 utility. The syntax is::
+
+      ip link set <PF iface> vf <VF id> mac <macaddr>
+
+   Example output:
+
+   .. code-block:: console
+
+      ip link set p4p1 vf 0 mac F2:A8:1B:5E:B4:66
+
+#. Assign VF(s) to VM.
+
+   The VF devices may be passed through to the guest VM using qemu or
+   virt-manager or virsh etc.
+
+   Example qemu guest launch command:
+
+   .. code-block:: console
+
+      ./qemu-system-x86_64 -name lio-vm -machine accel=kvm \
+      -cpu host -m 4096 -smp 4 \
+      -drive file=<disk_file>,if=none,id=disk1,format=<type> \
+      -device virtio-blk-pci,scsi=off,drive=disk1,id=virtio-disk1,bootindex=1 \
+      -device vfio-pci,host=03:00.3 -device vfio-pci,host=03:08.3
+
+#. Running testpmd
+
+   Refer to the document
+   :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>` to run
+   ``testpmd`` application.
+
+   .. note::
+
+      Use ``igb_uio`` instead of ``vfio-pci`` in VM.
+
+   Example output:
+
+   .. code-block:: console
+
+      [...]
+      EAL: PCI device 0000:03:00.3 on NUMA socket 0
+      EAL:   probe driver: 177d:9712 net_liovf
+      EAL:   using IOMMU type 1 (Type 1)
+      PMD: net_liovf[03:00.3]INFO: DEVICE : CN23XX VF
+      EAL: PCI device 0000:03:08.3 on NUMA socket 0
+      EAL:   probe driver: 177d:9712 net_liovf
+      PMD: net_liovf[03:08.3]INFO: DEVICE : CN23XX VF
+      Interactive-mode selected
+      USER1: create a new mbuf pool <mbuf_pool_socket_0>: n=171456, size=2176, socket=0
+      Configuring Port 0 (socket 0)
+      PMD: net_liovf[03:00.3]INFO: Starting port 0
+      Port 0: F2:A8:1B:5E:B4:66
+      Configuring Port 1 (socket 0)
+      PMD: net_liovf[03:08.3]INFO: Starting port 1
+      Port 1: 32:76:CC:EE:56:D7
+      Checking link statuses...
+      Port 0 Link Up - speed 10000 Mbps - full-duplex
+      Port 1 Link Up - speed 10000 Mbps - full-duplex
+      Done
+      testpmd>
+
+
+Limitations
+-----------
+
+VF MTU
+~~~~~~
+
+VF MTU is limited by PF MTU. Raise PF value before configuring VF for larger packet size.
+
+VLAN offload
+~~~~~~~~~~~~
+
+Tx VLAN insertion is not supported and consequently VLAN offload feature is
+marked partial.
+
+Ring size
+~~~~~~~~~
+
+Number of descriptors for Rx/Tx ring should be in the range 128 to 512.
+
+CRC striping
+~~~~~~~~~~~~
+
+LiquidIO adapters strip ethernet FCS of every packet coming to the host
+interface. So, CRC will be stripped even when the ``rxmode.hw_strip_crc``
+member is set to 0 in ``struct rte_eth_conf``.