New upstream version 17.11-rc3
[deb_dpdk.git] / examples / vhost_xen / xen_vhost.h
diff --git a/examples/vhost_xen/xen_vhost.h b/examples/vhost_xen/xen_vhost.h
deleted file mode 100644 (file)
index 2fc304c..0000000
+++ /dev/null
@@ -1,148 +0,0 @@
-/*-
- *   BSD LICENSE
- *
- *   Copyright(c) 2010-2014 Intel Corporation. All rights reserved.
- *   All rights reserved.
- *
- *   Redistribution and use in source and binary forms, with or without
- *   modification, are permitted provided that the following conditions
- *   are met:
- *
- *     * Redistributions of source code must retain the above copyright
- *       notice, this list of conditions and the following disclaimer.
- *     * Redistributions in binary form must reproduce the above copyright
- *       notice, this list of conditions and the following disclaimer in
- *       the documentation and/or other materials provided with the
- *       distribution.
- *     * Neither the name of Intel Corporation nor the names of its
- *       contributors may be used to endorse or promote products derived
- *       from this software without specific prior written permission.
- *
- *   THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
- *   "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
- *   LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
- *   A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
- *   OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
- *   SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
- *   LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
- *   DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
- *   THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
- *   (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
- *   OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
- */
-
-#ifndef _XEN_VHOST_H_
-#define _XEN_VHOST_H_
-
-#include <stdint.h>
-
-#include <rte_ether.h>
-
-#include "virtio-net.h"
-
-#define RTE_LOGTYPE_XENHOST RTE_LOGTYPE_USER1
-
-#define XEN_VM_ROOTNODE_FMT  "/local/domain/%d/control/dpdk"
-#define XEN_VM_NODE_FMT      "/local/domain/%d/control/dpdk/%s"
-#define XEN_MEMPOOL_SUFFIX   "mempool_gref"
-#define XEN_RXVRING_SUFFIX   "rx_vring_gref"
-#define XEN_TXVRING_SUFFIX   "tx_vring_gref"
-#define XEN_GVA_SUFFIX       "mempool_va"
-#define XEN_VRINGFLAG_SUFFIX "vring_flag"
-#define XEN_ADDR_SUFFIX      "ether_addr"
-#define VIRTIO_START         "event_type_start_"
-
-#define XEN_GREF_SPLITTOKEN  ','
-
-#define MAX_XENVIRT_MEMPOOL 16
-#define MAX_VIRTIO  32
-#define MAX_GREF_PER_NODE 64  /* 128 MB memory */
-
-#define PAGE_SIZE   4096
-#define PAGE_PFNNUM (PAGE_SIZE / sizeof(uint32_t))
-
-#define XEN_GNTDEV_FNAME "/dev/xen/gntdev"
-
-/* xen grant reference info in one grant node */
-struct xen_gnt {
-       uint32_t gref;  /* grant reference for this node */
-       union {
-               int gref;               /* grant reference */
-               uint32_t pfn_num;       /* guest pfn number of grant reference */
-       } gref_pfn[PAGE_PFNNUM];
-}__attribute__((__packed__));
-
-
-/* structure for mempool or vring node list */
-struct xen_gntnode {
-       uint32_t gnt_num;           /* grant reference number */
-       struct xen_gnt *gnt_info;   /* grant reference info */
-};
-
-
-struct xen_vring {
-       uint32_t dom_id;
-       uint32_t virtio_idx;    /* index of virtio device */
-       void *rxvring_addr;     /* mapped virtual address of rxvring */
-       void *txvring_addr;     /* mapped virtual address of txvring */
-       uint32_t rxpfn_num;     /* number of gpfn for rxvring */
-       uint32_t txpfn_num;     /* number of gpfn for txvring */
-       uint32_t *rxpfn_tbl;    /* array of rxvring gpfn */
-       uint32_t *txpfn_tbl;    /* array of txvring gpfn */
-       uint64_t *rx_pindex;    /* index used to release rx grefs */
-       uint64_t *tx_pindex;    /* index used to release tx grefs */
-       uint64_t  flag_index;
-       uint8_t  *flag;         /* cleared to zero on guest unmap */
-       struct ether_addr addr; /* ethernet address of virtio device */
-       uint8_t   removed;
-
-};
-
-struct xen_mempool {
-       uint32_t dom_id;      /* guest domain id */
-       uint32_t pool_idx;    /* index of memory pool */
-       void *gva;            /* guest virtual address of mbuf pool */
-       void *hva;            /* host virtual address of mbuf pool */
-       uint32_t mempfn_num;  /* number of gpfn for mbuf pool */
-       uint32_t *mempfn_tbl; /* array of mbuf pool gpfn */
-       uint64_t *pindex;     /* index used to release grefs */
-};
-
-struct xen_guest {
-       TAILQ_ENTRY(xen_guest) next;
-       int32_t dom_id;       /* guest domain id */
-       uint32_t pool_num;    /* number of mbuf pool of the guest */
-       uint32_t vring_num;   /* number of virtio ports of the guest */
-       /* array contain the guest mbuf pool info */
-       struct xen_mempool mempool[MAX_XENVIRT_MEMPOOL];
-       /* array contain the guest rx/tx vring info */
-       struct xen_vring vring[MAX_VIRTIO];
-};
-
-TAILQ_HEAD(xen_guestlist, xen_guest);
-
-int
-parse_mempoolnode(struct xen_guest *guest);
-
-int
-xenhost_init(void);
-
-int
-parse_vringnode(struct xen_guest *guest, uint32_t virtio_idx);
-
-int
-parse_mempoolnode(struct xen_guest *guest);
-
-void
-cleanup_mempool(struct xen_mempool *mempool);
-
-void
-cleanup_vring(struct xen_vring *vring);
-
-void
-virtio_monitor_loop(void);
-
-int
-init_virtio_xen(struct virtio_net_device_ops const * const);
-
-#endif