X-Git-Url: https://gerrit.fd.io/r/gitweb?p=deb_dpdk.git;a=blobdiff_plain;f=doc%2Fguides%2Fnics%2Fenic.rst;h=438a83d5fc5d06e6c00d0ab43149d10ebbb5c24f;hp=4dffce1a69426943e70b256598e4ee484471f607;hb=b63264c8342e6a1b6971c79550d2af2024b6a4de;hpb=ca33590b6af032bff57d9cc70455660466a654b2 diff --git a/doc/guides/nics/enic.rst b/doc/guides/nics/enic.rst index 4dffce1a..438a83d5 100644 --- a/doc/guides/nics/enic.rst +++ b/doc/guides/nics/enic.rst @@ -1,32 +1,7 @@ -.. BSD LICENSE +.. SPDX-License-Identifier: BSD-3-Clause Copyright (c) 2017, Cisco Systems, Inc. All rights reserved. - Redistribution and use in source and binary forms, with or without - modification, are permitted provided that the following conditions - are met: - - 1. Redistributions of source code must retain the above copyright - notice, this list of conditions and the following disclaimer. - - 2. Redistributions in binary form must reproduce the above copyright - notice, this list of conditions and the following disclaimer in - the documentation and/or other materials provided with the - distribution. - - THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS - "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT - LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS - FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE - COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, - INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, - BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; - LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER - CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT - LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN - ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE - POSSIBILITY OF SUCH DAMAGE. - ENIC Poll Mode Driver ===================== @@ -114,11 +89,24 @@ Configuration information - **Interrupts** - Only one interrupt per vNIC interface should be configured in the UCS + At least one interrupt per vNIC interface should be configured in the UCS manager regardless of the number receive/transmit queues. The ENIC PMD uses this interrupt to get information about link status and errors in the fast path. + In addition to the interrupt for link status and errors, when using Rx queue + interrupts, increase the number of configured interrupts so that there is at + least one interrupt for each Rx queue. For example, if the app uses 3 Rx + queues and wants to use per-queue interrupts, configure 4 (3 + 1) interrupts. + + - **Receive Side Scaling** + + In order to fully utilize RSS in DPDK, enable all RSS related settings in + CIMC or UCSM. These include the following items listed under + Receive Side Scaling: + TCP, IPv4, TCP-IPv4, IPv6, TCP-IPv6, IPv6 Extension, TCP-IPv6 Extension. + + .. _enic-flow-director: Flow director support @@ -140,20 +128,21 @@ perfect filtering of the 5-tuple with no masking of fields supported. SR-IOV mode utilization ----------------------- -UCS blade servers configured with dynamic vNIC connection policies in UCS -manager are capable of supporting assigned devices on virtual machines (VMs) -through a KVM hypervisor. Assigned devices, also known as 'passthrough' -devices, are SR-IOV virtual functions (VFs) on the host which are exposed -to VM instances. +UCS blade servers configured with dynamic vNIC connection policies in UCSM +are capable of supporting SR-IOV. SR-IOV virtual functions (VFs) are +specialized vNICs, distinct from regular Ethernet vNICs. These VFs can be +directly assigned to virtual machines (VMs) as 'passthrough' devices. -The Cisco Virtual Machine Fabric Extender (VM-FEX) gives the VM a dedicated +In UCS, SR-IOV VFs require the use of the Cisco Virtual Machine Fabric Extender +(VM-FEX), which gives the VM a dedicated interface on the Fabric Interconnect (FI). Layer 2 switching is done at the FI. This may eliminate the requirement for software switching on the host to route intra-host VM traffic. Please refer to `Creating a Dynamic vNIC Connection Policy `_ -for information on configuring SR-IOV adapter policies using UCS manager. +for information on configuring SR-IOV adapter policies and port profiles +using UCSM. Once the policies are in place and the host OS is rebooted, VFs should be visible on the host, E.g.: @@ -170,30 +159,37 @@ visible on the host, E.g.: 0d:00.6 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2) 0d:00.7 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2) -Enable Intel IOMMU on the host and install KVM and libvirt. A VM instance should -be created with an assigned device. When using libvirt, this configuration can -be done within the domain (i.e. VM) config file. For example this entry maps -host VF 0d:00:01 into the VM. +Enable Intel IOMMU on the host and install KVM and libvirt, and reboot again as +required. Then, using libvirt, create a VM instance with an assigned device. +Below is an example ``interface`` block (part of the domain configuration XML) +that adds the host VF 0d:00:01 to the VM. ``profileid='pp-vlan-25'`` indicates +the port profile that has been configured in UCSM. .. code-block:: console +
+ + + + + Alternatively, the configuration can be done in a separate file using the ``network`` keyword. These methods are described in the libvirt documentation for `Network XML format `_. -When the VM instance is started, the ENIC KVM driver will bind the host VF to +When the VM instance is started, libvirt will bind the host VF to vfio, complete provisioning on the FI and bring up the link. .. note:: It is not possible to use a VF directly from the host because it is not - fully provisioned until the hypervisor brings up the VM that it is assigned + fully provisioned until libvirt brings up the VM that it is assigned to. In the VM instance, the VF will now be visible. E.g., here the VF 00:04.0 is @@ -207,9 +203,27 @@ seen on the VM instance and should be available for binding to a DPDK. Follow the normal DPDK install procedure, binding the VF to either ``igb_uio`` or ``vfio`` in non-IOMMU mode. +In the VM, the kernel enic driver may be automatically bound to the VF during +boot. Unbinding it currently hangs due to a known issue with the driver. To +work around the issue, blacklist the enic module as follows. Please see :ref:`Limitations ` for limitations in the use of SR-IOV. +.. code-block:: console + + # cat /etc/modprobe.d/enic.conf + blacklist enic + + # dracut --force + +.. note:: + + Passthrough does not require SR-IOV. If VM-FEX is not desired, the user + may create as many regular vNICs as necessary and assign them to VMs as + passthrough devices. Since these vNICs are not SR-IOV VFs, using them as + passthrough devices do not require libvirt, port profiles, and VM-FEX. + + .. _enic-genic-flow-api: Generic Flow API support @@ -227,7 +241,7 @@ Generic Flow API is supported. The baseline support is: - Actions: queue and void - Selectors: 'is' -- **1300 series VICS with advanced filters disabled** +- **1300 and later series VICS with advanced filters disabled** With advanced filters disabled, an IPv4 or IPv6 item must be specified in the pattern. @@ -238,17 +252,99 @@ Generic Flow API is supported. The baseline support is: - Selectors: 'is', 'spec' and 'mask'. 'last' is not supported - In total, up to 64 bytes of mask is allowed across all headers -- **1300 series VICS with advanced filters enabled** +- **1300 and later series VICS with advanced filters enabled** - Attributes: ingress - Items: eth, ipv4, ipv6, udp, tcp, vxlan, inner eth, ipv4, ipv6, udp, tcp - - Actions: queue, mark, flag and void + - Actions: queue, mark, drop, flag and void - Selectors: 'is', 'spec' and 'mask'. 'last' is not supported - In total, up to 64 bytes of mask is allowed across all headers More features may be added in future firmware and new versions of the VIC. Please refer to the release notes. +.. _overlay_offload: + +Overlay Offload +--------------- + +Recent hardware models support overlay offload. When enabled, the NIC performs +the following operations for VXLAN, NVGRE, and GENEVE packets. In all cases, +inner and outer packets can be IPv4 or IPv6. + +- TSO for VXLAN and GENEVE packets. + + Hardware supports NVGRE TSO, but DPDK currently has no NVGRE offload flags. + +- Tx checksum offloads. + + The NIC fills in IPv4/UDP/TCP checksums for both inner and outer packets. + +- Rx checksum offloads. + + The NIC validates IPv4/UDP/TCP checksums of both inner and outer packets. + Good checksum flags (e.g. ``PKT_RX_L4_CKSUM_GOOD``) indicate that the inner + packet has the correct checksum, and if applicable, the outer packet also + has the correct checksum. Bad checksum flags (e.g. ``PKT_RX_L4_CKSUM_BAD``) + indicate that the inner and/or outer packets have invalid checksum values. + +- Inner Rx packet type classification + + PMD sets inner L3/L4 packet types (e.g. ``RTE_PTYPE_INNER_L4_TCP``), and + ``RTE_PTYPE_TUNNEL_GRENAT`` to indicate that the packet is tunneled. + PMD does not set L3/L4 packet types for outer packets. + +- Inner RSS + + RSS hash calculation, therefore queue selection, is done on inner packets. + +In order to enable overlay offload, the 'Enable VXLAN' box should be checked +via CIMC or UCSM followed by a reboot of the server. When PMD successfully +enables overlay offload, it prints the following message on the console. + +.. code-block:: console + + Overlay offload is enabled + +By default, PMD enables overlay offload if hardware supports it. To disable +it, set ``devargs`` parameter ``disable-overlay=1``. For example:: + + -w 12:00.0,disable-overlay=1 + +By default, the NIC uses 4789 as the VXLAN port. The user may change +it through ``rte_eth_dev_udp_tunnel_port_{add,delete}``. However, as +the current NIC has a single VXLAN port number, the user cannot +configure multiple port numbers. + +Ingress VLAN Rewrite +-------------------- + +VIC adapters can tag, untag, or modify the VLAN headers of ingress +packets. The ingress VLAN rewrite mode controls this behavior. By +default, it is set to pass-through, where the NIC does not modify the +VLAN header in any way so that the application can see the original +header. This mode is sufficient for many applications, but may not be +suitable for others. Such applications may change the mode by setting +``devargs`` parameter ``ig-vlan-rewrite`` to one of the following. + +- ``pass``: Pass-through mode. The NIC does not modify the VLAN + header. This is the default mode. + +- ``priority``: Priority-tag default VLAN mode. If the ingress packet + is tagged with the default VLAN, the NIC replaces its VLAN header + with the priority tag (VLAN ID 0). + +- ``trunk``: Default trunk mode. The NIC tags untagged ingress packets + with the default VLAN. Tagged ingress packets are not modified. To + the application, every packet appears as tagged. + +- ``untag``: Untag default VLAN mode. If the ingress packet is tagged + with the default VLAN, the NIC removes or untags its VLAN header so + that the application sees an untagged packet. As a result, the + default VLAN becomes `untagged`. This mode can be useful for + applications such as OVS-DPDK performance benchmarks that utilize + only the default VLAN and want to see only untagged packets. + .. _enic_limitations: Limitations @@ -264,9 +360,10 @@ Limitations In test setups where an Ethernet port of a Cisco adapter in TRUNK mode is connected point-to-point to another adapter port or connected though a router instead of a switch, all ingress packets will be VLAN tagged. Programs such - as l3fwd which do not account for VLAN tags in packets will misbehave. The - solution is to enable VLAN stripping on ingress. The following code fragment is - an example of how to accomplish this: + as l3fwd may not account for VLAN tags in packets and may misbehave. One + solution is to enable VLAN stripping on ingress so the VLAN tag is removed + from the packet and put into the mbuf->vlan_tci field. Here is an example + of how to accomplish this: .. code-block:: console @@ -274,6 +371,14 @@ Limitations vlan_offload |= ETH_VLAN_STRIP_OFFLOAD; rte_eth_dev_set_vlan_offload(port, vlan_offload); +Another alternative is modify the adapter's ingress VLAN rewrite mode so that +packets with the default VLAN tag are stripped by the adapter and presented to +DPDK as untagged packets. In this case mbuf->vlan_tci and the PKT_RX_VLAN and +PKT_RX_VLAN_STRIPPED mbuf flags would not be set. This mode is enabled with the +``devargs`` parameter ``ig-vlan-rewrite=untag``. For example:: + + -w 12:00.0,ig-vlan-rewrite=untag + - Limited flow director support on 1200 series and 1300 series Cisco VIC adapters with old firmware. Please see :ref:`enic-flow-director`. @@ -305,6 +410,24 @@ Limitations were added. Since there currently is no grouping or priority support, 'catch-all' filters should be added last. +- **Statistics** + + - ``rx_good_bytes`` (ibytes) always includes VLAN header (4B) and CRC bytes (4B). + This behavior applies to 1300 and older series VIC adapters. + 1400 series VICs do not count CRC bytes, and count VLAN header only when VLAN + stripping is disabled. + - When the NIC drops a packet because the Rx queue has no free buffers, + ``rx_good_bytes`` still increments by 4B if the packet is not VLAN tagged or + VLAN stripping is disabled, or by 8B if the packet is VLAN tagged and stripping + is enabled. + This behavior applies to 1300 and older series VIC adapters. 1400 series VICs + do not increment this byte counter when packets are dropped. + +- **RSS Hashing** + + - Hardware enables and disables UDP and TCP RSS hashing together. The driver + cannot control UDP and TCP hashing individually. + How to build the suite ---------------------- @@ -322,17 +445,9 @@ Supported Cisco VIC adapters ENIC PMD supports all recent generations of Cisco VIC adapters including: -- VIC 1280 -- VIC 1240 -- VIC 1225 -- VIC 1285 -- VIC 1225T -- VIC 1227 -- VIC 1227T -- VIC 1380 -- VIC 1340 -- VIC 1385 -- VIC 1387 +- VIC 1200 series +- VIC 1300 series +- VIC 1400 series Supported Operating Systems --------------------------- @@ -356,10 +471,16 @@ Supported features - VLAN filtering (supported via UCSM/CIMC only) - Execution of application by unprivileged system users - IPV4, IPV6 and TCP RSS hashing +- UDP RSS hashing (1400 series and later adapters) - Scattered Rx - MTU update - SR-IOV on UCS managed servers connected to Fabric Interconnects - Flow API +- Overlay offload + + - Rx/Tx checksum offloads for VXLAN, NVGRE, GENEVE + - TSO for VXLAN and GENEVE packets + - Inner RSS Known bugs and unsupported features in this release --------------------------------------------------- @@ -369,8 +490,8 @@ Known bugs and unsupported features in this release - VLAN based flow direction - Non-IPV4 flow direction - Setting of extended VLAN -- UDP RSS hashing - MTU update only works if Scattered Rx mode is disabled +- Maximum receive packet length is ignored if Scattered Rx mode is used Prerequisites ------------- @@ -427,4 +548,4 @@ Any questions or bugs should be reported to DPDK community and to the ENIC PMD maintainers: - John Daley -- Nelson Escobar +- Hyong Youb Kim