3 title: "FD.io CSIT Testbed Specifications"
7 # FD.io CSIT Testbed Specifications
11 This note includes specification of the physical testbed infrastructure
12 hosted by LFN FD.io CSIT project.
19 #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr
20 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0
21 2. 1-Node-Cascadelake nomad clx na 1 1 0 0 0 0 0 0 0 1 0 0 0 0
22 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 0
23 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0
24 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0
25 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0
26 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0
27 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0
28 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0
29 10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0
30 11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0
31 12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0
32 13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0
33 13. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8
34 Totals: 28 35 18.5 7 1 2 1 2 4 7 2 15.5 2 8
37 ### 1-Node-Skylake Xeon Intel (1n-skx)
39 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
40 ports connected back-to-back ([Server Types](#server-types)).
41 Used for FD.io VPP_Device functional driver tests.
43 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
45 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
46 ports connected back-to-back ([Server Types](#server-types)).
47 Used for FD.io VPP_Device functional driver tests.
49 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
51 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
52 NIC ports connected back-to-back ([Server Types](#server-types)).
54 Used for FD.io VPP_Device functional driver tests.
56 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
58 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
59 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
60 circular topology ([Server Types](#server-types)).
61 Used for FD.io TCP/IP and HTTP performance tests.
63 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
65 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
66 one TG (Server-Type-C3) connected in a 2-node circular topology
67 ([Server Types](#server-types)).
68 Used for FD.io performance tests.
70 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
72 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
73 one TG (Server-Type-D2) connected in a 2-node circular topology
74 ([Server Types](#server-types)).
75 Used for FD.io performance tests.
77 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
79 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
80 one TG (Server-Type-E31) connected in a 2-node circular topology
81 ([Server Types](#server-types)).
82 Used for FD.io performance tests.
84 ### 2-Node-Icelake Xeon Intel (2n-icx)
86 Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
87 one TG (Server-Type-F2) connected in a 2-node circular topology
88 ([Server Types](#server-types)).
89 Used for FD.io performance tests.
91 ### 3-Node-Rangeley Atom Testbeds
93 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
94 TG (Server-Type-2) connected in a 3-node circular topology
95 ([Server Types](#server-types)).
96 Used for FD.io performance tests.
98 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
100 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
101 TG (Server-Type-E31) connected in a 3-node circular topology
102 ([Server Types](#server-types)).
103 Used for FD.io performance tests.
105 ### 3-Node-Altra Arm Ampere (3n-alt)
107 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
108 TG (Server-Type-F4) connected in a 3-node circular topology
109 ([Server Types](#server-types)).
110 Used for FD.io performance tests.
112 ### 3-Node-Icelake Xeon Intel (3n-icx)
114 Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
115 TG (Server-Type-F3) connected in a 3-node circular topology
116 ([Server Types](#server-types)).
117 Used for FD.io performance tests.
119 ### 3-Node-SnowRidge Atom Intel (3n-snr)
121 Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
122 TG (Server-Type-F4) connected in a 3-node circular topology
123 ([Server Types](#server-types)).
124 Used for FD.io performance tests.
126 ### 2-Node-Full-SapphireRapids Xeon Intel (2nf-spr)
128 One 2-Node-Full-SapphireRapids testbed includes one SUT (Server-Type-H1) and
129 one TG (Server-Type-H2) connected in a 2-node physical topology
130 with NUMA (socket) daisy chaining. For more detail see
131 [Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
132 Used for FD.io performance tests in a full system SUT setup with all PCIe
133 Gen5 x16 lane slots populated with 2p200GbE NICs.
135 ### 2-Node-SapphireRapids Xeon Intel (2n-spr)
137 Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and
138 one TG (Server-Type-H6) connected in a 2-node circular topology. For more
139 detail see [Server Types](#server-types) and [Testbed Topology-TODO](#TODO).
140 Used for FD.io performance tests.
146 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
147 Management port, which are connected to two different VLANs.
151 - Subnet: 10.30.50.0/24
152 - Gateway: 10.30.50.1
153 - Broadcast: 10.30.50.255
154 - DNS1: 199.204.44.24
155 - DNS2: 199.204.47.54
157 - Subnet: 10.30.51.0/24
158 - Gateway: 10.30.51.1
159 - Broadcast: 10.30.51.255
160 - DNS1: 199.204.44.24
161 - DNS2: 199.204.47.54
164 To access these hosts, VPN connection is required.
166 ## Server Specifications
170 FD.io CSIT lab contains following server types:
172 1. Server-Type-B2: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
174 - Physical connectivity:
175 - IPMI and host management ports.
176 - Main HW configuration:
177 - Chassis: SuperMicro SYS-7049GP-TRT.
178 - Motherboard: SuperMicro X11DPG-QT.
179 - Processors: 2* Intel Platinum 8180 2.5 GHz.
180 - RAM Memory: 16* 16GB DDR4-2666MHz.
181 - Disks: 2* 1.6TB 6G SATA SSD.
182 - NICs configuration:
183 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
184 - PCIe Slot2 18:00.xx: empty.
185 - PCIe Slot4 3b:00.xx: empty.
186 - PCIe Slot9 5e:00.xx: empty.
187 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
188 - PCIe Slot6 86:00.xx: empty.
189 - PCIe Slot8 af:00.xx: empty.
190 - PCIe Slot10 d8:00.xx: empty.
191 2. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
193 - Physical connectivity:
194 - IPMI and host management ports.
195 - NIC ports connected into 1-node topologies.
196 - Main HW configuration:
197 - Chassis: SuperMicro SYS-7049GP-TRT.
198 - Motherboard: SuperMicro X11DPG-QT.
199 - Processors: 2* Intel Platinum 8180 2.5 GHz.
200 - RAM Memory: 16* 16GB DDR4-2666MHz.
201 - Disks: 2* 1.6TB 6G SATA SSD.
202 - NICs configuration:
203 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
204 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
205 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
206 - PCIe Slot9 5e:00.xx: empty.
207 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
208 - PCIe Slot6 86:00.xx: empty.
209 - PCIe Slot8 af:00.xx: empty.
210 - PCIe Slot10 d8:00.xx: empty.
211 3. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
213 - Physical connectivity:
214 - Host management interface: 10/100/1000-BaseT.
215 - 8-port 10GE SFP+ integrated NIC.
216 - Main HW configuration:
217 - Chassis: PS10GE4NG.
218 - Motherboard: SuperMicro X11DPG-QT.
219 - Processors: Quad-Core, Intel Processor.
220 - HW accelerators: FPGA offload.
222 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
223 - Physical Interfaces: 4 * 10GE SFP+.
224 - Operating System: Native IxOS.
225 - Interface configuration:
230 4. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
232 - Physical connectivity:
233 - IPMI and host management ports.
235 - Main HW configuration:
236 - Chassis: SuperMicro SYS-7049GP-TRT.
237 - Motherboard: SuperMicro X11DPG-QT.
238 - Processors: 2* Intel Platinum 8180 2.5 GHz.
239 - RAM Memory: 16* 16GB DDR4-2666MHz.
240 - Disks: 2* 1.6TB 6G SATA SSD.
241 - NICs configuration:
242 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
243 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
244 - PCIe Slot4 3b:00.xx: empty.
245 - PCIe Slot9 5e:00.xx: empty.
246 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
247 - PCIe Slot6 86:00.xx: empty.
248 - PCIe Slot8 af:00.xx: empty.
249 - PCIe Slot10 d8:00.xx: empty.
250 5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
252 - Physical connectivity:
253 - IPMI and host management ports.
254 - NIC ports connected into 1-node testbed topologies.
255 - Main HW configuration:
256 - Chassis: SuperMicro SYS-7049GP-TRT.
257 - Motherboard: SuperMicro X11DPG-QT.
258 - Processors: 2* Intel Platinum 8280 2.7 GHz.
259 - RAM Memory: 12* 16GB DDR4-2933.
260 - Disks: 2* 1.92TB SATA SSD.
261 - NICs configuration:
262 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
263 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
264 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
265 - PCIe Slot9 5e:00.xx: empty.
266 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
267 - PCIe Slot6 86:00.xx: empty.
268 - PCIe Slot8 af:00.xx: empty.
269 - PCIe Slot10 d8:00.xx: empty.
270 6. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
272 - Physical connectivity:
273 - IPMI and host management ports.
274 - NIC ports connected into 2-node testbed topologies.
275 - Main HW configuration:
276 - Chassis: SuperMicro SYS-7049GP-TRT.
277 - Motherboard: SuperMicro X11DPG-QT.
278 - Processors: 2* Intel Gold 6252N 2.3 GHz.
279 - RAM Memory: 12* 16GB DDR4-2933.
280 - Disks: 2* 1.92TB SATA SSD.
281 - NICs configuration:
282 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
283 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
284 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
285 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
286 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
287 - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
288 - PCIe Slot8 af:00.xx: empty.
289 - PCIe Slot10 d8:00.xx: empty.
290 7. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
292 - Physical connectivity:
293 - IPMI and host management ports.
294 - NIC ports connected into 2-node testbed topologies.
295 - Main HW configuration:
296 - Chassis: SuperMicro SYS-7049GP-TRT.
297 - Motherboard: SuperMicro X11DPG-QT.
298 - Processors: 2* Intel Platinum 8280 2.7 GHz.
299 - RAM Memory: 12* 16GB DDR4-2933.
300 - Disks: 2* 1.92TB SATA SSD.
301 - NICs configuration:
302 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
303 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
304 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
305 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
306 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
307 - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
308 - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
309 - PCIe Slot10 d8:00.xx: empty.
310 8. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
312 - Physical connectivity:
313 - IPMI and host management ports.
314 - no NIC ports, standalone setup.
315 - Main HW configuration:
316 - Chassis: SuperMicro 1029P-WTRT.
317 - Motherboard: SuperMicro X11DDW-NT.
318 - Processors: 2* Intel Platinum 8280 2.7 GHz.
319 - RAM Memory: 12* 16GB DDR4-2933.
320 - Disks: 4* 1.92TB SATA SSD.
321 - NICs configuration:
326 9. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
328 - Physical connectivity:
329 - IPMI and host management ports.
330 - NIC ports connected into 2-node testbed topologies.
331 - Main HW configuration:
332 - Chassis: SuperMicro AS-1114S-WTRT
333 - Processors: 1* AMD EPYC 7532 2.4 GHz.
334 - RAM Memory: 8* 32GB DDR4-2933.
335 - Disks: 1* 1TB SATA SSD.
336 - NICs configuration:
337 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
338 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
339 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
340 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
341 10. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
343 - Physical connectivity:
344 - IPMI and host management ports.
345 - NIC ports connected into 2-node testbed topologies.
346 - Main HW configuration:
347 - Chassis: SuperMicro AS-1114S-WTRT
348 - Processors: 1* AMD EPYC 7532 2.4 GHz.
349 - RAM Memory: 8* 32GB DDR4-2933.
350 - Disks: 1* 1TB SATA SSD.
351 - NICs configuration:
352 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
353 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
354 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
355 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
356 11. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
358 - Physical connectivity:
359 - IPMI and host management ports.
360 - NIC ports connected into 1-node topologies.
361 - Main HW configuration:
362 - Chassis: GIGABYTE Rack Mount
363 - Motherboard: MT91-FS4-00
364 - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
365 - RAM Memory: 16 * 16GB DIMM
366 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
367 - NICs configuration:
369 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
370 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
372 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
373 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
374 12. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
376 - Physical connectivity:
377 - IPMI(?) and host management ports.
378 - NIC ports connected into 3-node topology.
379 - Main HW configuration:
380 - Chassis: Huawei TaiShan 2280.
381 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
382 - RAM Memory: 8* 16GB DDR4-2400MT/s
383 - Disks: 1* 4TB SATA HDD
384 - NICs configuration:
385 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
386 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
387 13. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
389 - Physical connectivity:
390 - IPMI and host management ports.
391 - NIC ports connected into 2-node topologies.
392 - Main HW configuration:
393 - Chassis: Gigabyte R181-T90 1U
394 - Motherboard: MT91-FS1
395 - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
396 - RAM Memory: 4* 32GB RDIMM
397 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
398 - NICs configuration:
402 - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
403 14. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
405 - Physical connectivity:
406 - IPMI and host management ports.
407 - NIC ports connected into 3-node topologies.
408 - Main HW configuration:
409 - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
410 - Motherboard: Mt.Jade Motherboard
411 - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
412 - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
413 - RAM Memory: 16* 8GB DDR4-3200MT/s
414 - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
415 - NICs configuration:
417 - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
420 15. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
422 - Physical connectivity:
423 - IPMI and host management ports.
424 - Main HW configuration:
425 - Chassis: Gigabyte R152-P30-00 1U
426 - Motherboard: MP32-AR1-00
427 - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
428 - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
429 - RAM Memory: 12* 16GB DDR4-3200MT/s
430 - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
431 16. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
433 - Physical connectivity:
434 - IPMI and host management ports.
435 - NIC ports connected into 2-node and 3-node topologies.
436 - Main HW configuration:
437 - Chassis: SuperMicro SYS-7049GP-TRT.
438 - Motherboard: SuperMicro X11DPG-QT.
439 - Processors: 2* Intel Platinum 8180 2.5 GHz.
440 - RAM Memory: 16* 16GB DDR4-2666MHz.
441 - Disks: 2* 1.6TB 6G SATA SSD.
442 - NICs configuration:
443 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
444 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
445 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
446 - PCIe Slot9 5e:00.xx: empty.
447 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
448 - PCIe Slot6 86:00.xx: empty.
449 - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
450 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
451 17. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
453 - Physical connectivity:
454 - IPMI and host management ports.
455 - NIC ports connected into 2-node or 3-node testbed topologies.
456 - Main HW configuration:
457 - Chassis: SuperMicro SYS-740GP-TNRT.
458 - Motherboard: Super X12DPG-QT6.
459 - Processors: 2* Intel Platinum 8358 2.6 GHz.
460 - RAM Memory: 16* 16GB DDR4-3200.
461 - Disks: 2* 960GB SATA SSD.
462 - NICs configuration:
463 - Numa0: (x16, x16, x16 PCIe4.0 lanes)
464 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
465 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
466 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
467 - Numa1: (x16, x16, x16 PCIe4.0 lanes)
468 - PCIe Slot6 86:00.xx: empty.
469 - PCIe Slot8 af:00.xx: empty.
470 - PCIe Slot10 d8:00.xx: empty.
471 18. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
473 - Physical connectivity:
474 - IPMI and host management ports.
475 - NIC ports connected into 2-node testbed topologies.
476 - Main HW configuration:
477 - Chassis: SuperMicro SYS-740GP-TNRT.
478 - Motherboard: Super X12DPG-QT6.
479 - Processors: 2* Intel Platinum 8358 2.6 GHz.
480 - RAM Memory: 16* 16GB DDR4-3200.
481 - Disks: 2* 960GB SATA SSD.
482 - NICs configuration:
483 - Numa0: (x16, x16, x16 PCIe4.0 lanes)
484 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
485 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
486 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
487 - Numa1: (x16, x16, x16 PCIe4.0 lanes)
488 - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
489 - PCIe Slot8 af:00.xx: empty.
490 - PCIe Slot10 d8:00.xx: empty.
491 19. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
493 - Physical connectivity:
494 - IPMI and host management ports.
495 - NIC ports connected into 3-node testbed topologies.
496 - Main HW configuration:
497 - Chassis: SuperMicro SYS-740GP-TNRT.
498 - Motherboard: Super X12DPG-QT6.
499 - Processors: 2* Intel Platinum 8358 2.6 GHz.
500 - RAM Memory: 16* 16GB DDR4-3200.
501 - Disks: 2* 960GB SATA SSD.
502 - NICs configuration:
503 - Numa0: (x16, x16, x16 PCIe4.0 lanes)
504 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
505 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
506 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
507 - Numa1: (x16, x16, x16 PCIe4.0 lanes)
508 - PCIe Slot6 86:00.xx: empty.
509 - PCIe Slot8 af:00.xx: empty.
510 - PCIe Slot10 d8:00.xx: empty.
511 20. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
513 - Physical connectivity:
514 - IPMI and host management ports.
515 - NIC ports connected into 2-node and/or 3-node testbed topologies.
516 - Main HW configuration:
517 - Chassis: SuperMicro SYS-740GP-TNRT.
518 - Motherboard: Super X12DPG-QT6.
519 - Processors: 2* Intel Platinum 8358 2.6 GHz.
520 - RAM Memory: 16* 16GB DDR4-3200.
521 - Disks: 2* 960GB SATA SSD.
522 - NICs configuration:
523 - Numa0: (x16, x16, x16 PCIe4.0 lanes)
524 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
525 - PCIe Slot4 3b:00.xx: empty.
526 - PCIe Slot9 5e:00.xx: empty.
527 - Numa1: (x16, x16, x16 PCIe4.0 lanes)
528 - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
529 - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
530 - PCIe Slot10 d8:00.xx: empty.
531 21. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
533 - Physical connectivity:
534 - IPMI and host management ports.
535 - NIC ports connected into 3-node testbed topology.
536 - Main HW configuration:
537 - Chassis: Intel JACOBSVILLE SDP.
538 - Motherboard: Intel JACOBSVILLE E63448-400.
539 - Processors: 1* Intel Atom P5362B 2.2 GHz.
540 - RAM Memory: 2* 16GB DDR4-2933.
541 - Disks: ?* ? SATA SSD.
542 - NICs configuration:
543 - Numa0: (x16, PCIe3.0 lane)
544 - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
545 22. Server-Type-H1: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
547 - Physical connectivity:
548 - IPMI and host management ports.
549 - NIC ports connected into 3-numa-node testbed topologies.
550 - Main HW configuration:
551 - Chassis: SuperMicro SYS-741GE-TNRT.
552 - Motherboard: Super X13DEG-QT-P.
553 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
554 - RAM Memory: 16* 32GB DDR5-4800.
555 - Disks: 2* 960GB SATA SSD.
556 - NICs configuration:
557 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
558 - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
559 - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
560 - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
561 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
562 - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
563 - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
564 - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
565 23. Server-Type-H2: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
567 - Physical connectivity:
568 - IPMI and host management ports.
569 - NIC ports connected into 3-numa-node testbed topologies.
570 - Main HW configuration:
571 - Chassis: SuperMicro SYS-741GE-TNRT.
572 - Motherboard: Super X13DEG-QT-P.
573 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
574 - RAM Memory: 16* 32GB DDR5-4800.
575 - Disks: 2* 960GB SATA SSD.
576 - NICs configuration:
577 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
578 - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
579 - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
580 - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
581 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
582 - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
583 - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
584 - PCIe Slot11 d8:00.xx: empty.
585 24. Server-Type-H3: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
587 - Physical connectivity:
588 - IPMI and host management ports.
589 - NIC ports connected into 3-numa-node testbed topologies.
590 - Main HW configuration:
591 - Chassis: SuperMicro SYS-741GE-TNRT.
592 - Motherboard: Super X13DEG-QT-P.
593 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
594 - RAM Memory: 16* 32GB DDR5-4800.
595 - Disks: 2* 960GB SATA SSD.
596 - NICs configuration:
597 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
598 - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
599 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
600 - PCIe Slot10 5e:00.xx: empty.
601 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
602 - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel.
603 - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
604 - PCIe Slot11 d8:00.xx: empty.
605 25. Server-Type-H4: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
607 - Physical connectivity:
608 - IPMI and host management ports.
609 - NIC ports connected into 3-numa-node testbed topologies.
610 - Main HW configuration:
611 - Chassis: SuperMicro SYS-741GE-TNRT.
612 - Motherboard: Super X13DEG-QT-P.
613 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
614 - RAM Memory: 16* 32GB DDR5-4800.
615 - Disks: 2* 960GB SATA SSD.
616 - NICs configuration:
617 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
618 - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
619 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
620 - PCIe Slot10 5e:00.xx: empty.
621 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
622 - PCIe Slot7 86:00.xx: empty.
623 - PCIe Slot9 af:00.xx: empty.
624 - PCIe Slot11 d8:00.xx: empty.
625 26. Server-Type-H5: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
627 - Physical connectivity:
628 - IPMI and host management ports.
629 - NIC ports connected into 2-node testbed topologies.
630 - Main HW configuration:
631 - Chassis: SuperMicro SYS-741GE-TNRT.
632 - Motherboard: Super X13DEG-QT-P.
633 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
634 - RAM Memory: 16* 32GB DDR5-4800.
635 - Disks: 2* 960GB SATA SSD.
636 - NICs configuration:
637 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
638 - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
639 - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
640 - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
641 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
642 - PCIe Slot7 86:00.xx: empty.
643 - PCIe Slot9 af:00.xx: empty.
644 - PCIe Slot11 d8:00.xx: empty.
645 27. Server-Type-H6: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
647 - Physical connectivity:
648 - IPMI and host management ports.
649 - NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test.
650 - Main HW configuration:
651 - Chassis: SuperMicro SYS-741GE-TNRT.
652 - Motherboard: Super X13DEG-QT-P.
653 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
654 - RAM Memory: 16* 32GB DDR5-4800.
655 - Disks: 2* 960GB SATA SSD.
656 - NICs configuration:
657 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
658 - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
659 - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
660 - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
661 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
662 - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
663 - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
664 - PCIe Slot11 d8:00.xx: empty.
667 ### Naming Convention
669 Following naming convention is used within this page to specify physical
670 connectivity and wiring across defined CSIT testbeds:
673 - testbedname: testbedN.
675 - traffic-generator: tN-tgW.
676 - system-under-testX: tN-sutX.
681 - N - testbed number.
682 - tgW - server acts as traffic-generator with W index.
683 - sutX - server acts as system-under-test with X index.
684 - Y - PCIe slot number denoting a NIC card number within the host.
685 - Z - port number on the NIC card.
688 ## Testbeds Configuration
690 ### Per Testbed Server Allocation and Naming
692 #### 1-Node-Skylake Servers (1n-skx) PROD
695 - SUT [Server-Type-B6]:
696 - testbedname: testbed11.
697 - hostname: s1-t11-sut1.
698 - IPMI IP: 10.30.50.47
699 - Host IP: 10.30.51.50
701 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
702 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
703 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
704 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
705 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
706 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
707 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
708 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
709 - SUT [Server-Type-B6]:
710 - testbedname: testbed12.
711 - hostname: s2-t12-sut1.
712 - IPMI IP: 10.30.50.48
713 - Host IP: 10.30.51.51
715 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
716 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
717 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
718 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
719 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
720 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
721 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
722 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
725 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
728 - SUT [Server-Type-E11]:
729 - testbedname: testbed13
730 - hostname: s55-t13-sut1
731 - IPMI IP: 10.30.50.70
732 - Host IP: 10.30.51.70
734 - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
735 - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
736 - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
737 - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
738 - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
739 - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
740 - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
741 - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
742 - SUT [Server-Type-E11]:
743 - testbedname: testbed14
744 - hostname: s56-t14-sut1
745 - IPMI IP: 10.30.50.71
746 - Host IP: 10.30.51.71
748 - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
749 - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
750 - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
751 - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
752 - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
753 - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
754 - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
755 - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
758 #### 1-Node-Cascadelake Servers (1n-clx) PROD
761 - SUT [Server-Type-C1]:
762 - testbedname: testbed11.
763 - hostname: s32-t14-sut1.
764 - IPMI IP: 10.30.55.17
765 - Host IP: 10.32.8.17
767 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
768 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
769 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
770 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
771 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
772 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
773 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
774 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
777 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
780 - SUT [Server-Type-B8]:
781 - testbedname: testbed25.
782 - hostname: s25-t25-sut1.
783 - IPMI IP: 10.30.50.58
784 - Host IP: 10.30.51.61
786 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
787 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
788 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
789 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
790 - TG [Server-Type-B7]:
791 - testbedname: testbed25.
792 - hostname: s26-t25-tg1.
793 - IPMI IP: 10.30.50.59
794 - Host IP: 10.30.51.62
796 - s26-t25-tg1-p1 - 10GE-port1.
797 - s26-t25-tg1-p2 - 10GE-port2.
798 - s26-t25-tg1-p3 - 10GE-port3.
799 - s26-t25-tg1-p4 - 10GE-port4.
802 #### 2-Node-Cascadelake Servers (2n-clx) PROD
805 - SUT [Server-Type-C2]:
806 - testbedname: testbed27.
807 - hostname: s33-t27-sut1.
808 - IPMI IP: 10.30.55.18
809 - Host IP: 10.32.8.18
811 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
812 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
813 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
814 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
815 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
816 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
817 - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
818 - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
819 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
820 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
821 - TG [Server-Type-C3]:
822 - testbedname: testbed27.
823 - hostname: s34-t27-tg1.
824 - IPMI IP: 10.30.55.19
825 - Host IP: 10.32.8.19
827 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
828 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
829 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
830 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
831 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
832 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
833 - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
834 - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
835 - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
836 - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
837 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
838 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
839 - SUT [Server-Type-C2]:
840 - testbedname: testbed28.
841 - hostname: s35-t28-sut1.
842 - IPMI IP: 10.30.55.20
843 - Host IP: 10.32.8.20
845 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
846 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
847 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
848 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
849 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
850 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
851 - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
852 - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
853 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
854 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
855 - TG [Server-Type-C3]:
856 - testbedname: testbed28.
857 - hostname: s36-t28-tg1.
858 - IPMI IP: 10.30.55.21
859 - Host IP: 10.32.8.21
861 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
862 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
863 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
864 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
865 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
866 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
867 - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
868 - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
869 - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
870 - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
871 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
872 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
873 - SUT [Server-Type-C2]:
874 - testbedname: testbed29.
875 - hostname: s37-t29-sut1.
876 - IPMI IP: 10.30.55.22
877 - Host IP: 10.32.8.22
879 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
880 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
881 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
882 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
883 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
884 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
885 - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
886 - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
887 - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
888 - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
889 - TG [Server-Type-C3]:
890 - testbedname: testbed29.
891 - hostname: s38-t29-tg1.
892 - IPMI IP: 10.30.55.23
893 - Host IP: 10.32.8.23
895 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
896 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
897 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
898 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
899 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
900 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
901 - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
902 - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
903 - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
904 - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
907 #### 2-Node-Zen2 Servers (2n-zn2) PROD
910 - SUT [Server-Type-D1]:
911 - testbedname: testbed210.
912 - hostname: s60-t210-sut1.
913 - IPMI IP: 10.30.55.24
914 - Host IP: 10.32.8.24
916 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
917 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
918 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
919 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
920 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
921 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
922 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
923 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
924 - TG [Server-Type-D2]:
925 - testbedname: testbed210.
926 - hostname: s61-t210-tg1.
927 - IPMI IP: 10.30.55.25
928 - Host IP: 10.32.8.25
930 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
931 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
932 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
933 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
934 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
935 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
936 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
937 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
940 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
942 Note: Server19 (TG) is shared between testbed33 & testbed211
945 - SUT [Server-Type-E22]:
946 - testbedname: testbed211.
947 - hostname: s27-t211-sut1.
948 - IPMI IP: 10.30.50.69
949 - Host IP: 10.30.51.69
951 - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
952 - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
953 - TG [Server-Type-E31]:
954 - testbedname: testbed33 and testbed211.
955 - hostname: s19-t33t211-tg1.
956 - IPMI IP: 10.30.50.46
957 - Host IP: 10.30.51.49
959 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
960 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
961 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
962 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
963 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
964 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
965 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
966 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
967 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
968 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
969 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
970 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
973 #### 2-Node-Icelake Servers (2n-icx) PROD
976 - SUT [Server-Type-F1]:
977 - testbedname: testbed212.
978 - hostname: s71-t212-sut1.
979 - IPMI IP: 10.30.50.81
980 - Host IP: 10.30.51.81
982 - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
983 - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
984 - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
985 - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
986 - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
987 - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
988 - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
989 - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
990 - TG [Server-Type-F2]:
991 - testbedname: testbed212.
992 - hostname: s72-t212-tg1.
993 - IPMI IP: 10.30.50.82
994 - Host IP: 10.30.51.82
996 - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
997 - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
998 - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
999 - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1000 - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1001 - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1002 - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1003 - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1004 - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1005 - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1006 - SUT [Server-Type-F1]:
1007 - testbedname: testbed213.
1008 - hostname: s83-t213-sut1.
1009 - IPMI IP: 10.30.50.83
1010 - Host IP: 10.30.51.83
1012 - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1013 - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1014 - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1015 - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1016 - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1017 - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1018 - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1019 - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1020 - TG [Server-Type-F2]:
1021 - testbedname: testbed213.
1022 - hostname: s84-t213-tg1.
1023 - IPMI IP: 10.30.50.84
1024 - Host IP: 10.30.51.84
1026 - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1027 - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1028 - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1029 - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1030 - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1031 - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1032 - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1033 - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1034 - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1035 - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1036 - SUT [Server-Type-F1]:
1037 - testbedname: testbed214.
1038 - hostname: s85-t214-sut1.
1039 - IPMI IP: 10.30.50.85
1040 - Host IP: 10.30.51.85
1042 - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1043 - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1044 - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1045 - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1046 - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1047 - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1048 - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1049 - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1050 - TG [Server-Type-F2]:
1051 - testbedname: testbed214.
1052 - hostname: s86-t214-tg1.
1053 - IPMI IP: 10.30.50.86
1054 - Host IP: 10.30.51.86
1056 - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1057 - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1058 - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1059 - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1060 - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1061 - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1062 - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1063 - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1064 - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1065 - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1066 - SUT [Server-Type-F1]:
1067 - testbedname: testbed215.
1068 - hostname: s87-t215-sut1.
1069 - IPMI IP: 10.30.50.87
1070 - Host IP: 10.30.51.87
1072 - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1073 - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1074 - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1075 - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1076 - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1077 - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1078 - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1079 - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1080 - TG [Server-Type-F2]:
1081 - testbedname: testbed215.
1082 - hostname: s88-t215-tg1.
1083 - IPMI IP: 10.30.50.88
1084 - Host IP: 10.30.51.88
1086 - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1087 - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1088 - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1089 - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1090 - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1091 - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1092 - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1093 - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1094 - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1095 - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1098 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1100 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1103 - ServerB22 [Server-Type-B5]:
1104 - testbedname: testbed35.
1105 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1106 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1107 - Host IP: 10.30.51.9
1109 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1110 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1112 - ServerB23 [Server-Type-B5]:
1113 - testbedname: testbed35.
1114 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1115 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1116 - Host IP: 10.30.51.10
1118 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1119 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1121 - ServerB24 [Server-Type-B5]:
1122 - testbedname: testbed35.
1123 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1124 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1125 - Host IP: 10.30.51.11
1127 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1128 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1132 #### 3-Node-Taishan Servers (3n-tsh) PROD
1134 Note: Server19 (TG) is shared between testbed33 & testbed211
1137 - SUT [Server-Type-E21]:
1138 - testbedname: testbed33.
1139 - hostname: s17-t33-sut1.
1140 - IPMI IP: 10.30.50.36
1141 - Host IP: 10.30.51.36
1143 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1144 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1145 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1146 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1147 - SUT [Server-Type-E21]:
1148 - testbedname: testbed33.
1149 - hostname: s18-t33-sut2.
1150 - IPMI IP: 10.30.50.37
1151 - Host IP: 10.30.51.37
1153 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1154 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1155 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1156 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1157 - TG [Server-Type-E31]:
1158 - testbedname: testbed33 and testbed211.
1159 - hostname: s19-t33t211-tg1.
1160 - IPMI IP: 10.30.50.46
1161 - Host IP: 10.30.51.49
1163 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1164 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1165 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1166 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1167 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1168 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1169 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1170 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1171 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1172 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1173 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1174 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1177 #### 3-Node-Altra Servers (3n-alt) PROD
1180 - SUT [Server-Type-E23]:
1181 - testbedname: testbed34.
1182 - hostname: s62-t34-sut1.
1183 - IPMI IP: 10.30.50.72
1184 - Host IP: 10.30.51.72
1186 - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1187 - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1188 - SUT [Server-Type-E23]:
1189 - testbedname: testbed34.
1190 - hostname: s63-t34-sut2.
1191 - IPMI IP: 10.30.50.73
1192 - Host IP: 10.30.51.73
1194 - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1195 - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1196 - TG [Server-Type-F4]:
1197 - testbedname: testbed34.
1198 - hostname: s64-t34-tg1.
1199 - IPMI IP: 10.30.50.74
1200 - Host IP: 10.30.51.74
1202 - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1203 - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1204 - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1205 - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1206 - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1207 - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1208 - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1209 - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1210 - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1211 - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1214 #### 3-Node-Icelake Servers (3n-icx) PROD
1217 - ServerF1 [Server-Type-F1]:
1218 - testbedname: testbed37.
1219 - hostname: s65-t37-sut1.
1220 - IPMI IP: 10.30.50.75
1221 - Host IP: 10.30.51.75
1223 - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1224 - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1225 - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1226 - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1227 - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1228 - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1229 - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1230 - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1231 - ServerF1 [Server-Type-F1]:
1232 - testbedname: testbed37.
1233 - hostname: s66-t37-sut2.
1234 - IPMI IP: 10.30.50.76
1235 - Host IP: 10.30.51.76
1237 - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1238 - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1239 - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1240 - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1241 - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1242 - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1243 - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1244 - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1245 - ServerF3 [Server-Type-F3]:
1246 - testbedname: testbed37.
1247 - hostname: s67-t37-tg1.
1248 - IPMI IP: 10.30.50.77
1249 - Host IP: 10.30.51.77
1251 - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1252 - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1253 - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1254 - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1255 - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1256 - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1257 - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1258 - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1259 - ServerF1 [Server-Type-F1]:
1260 - testbedname: testbed38.
1261 - hostname: s78-t38-sut1.
1262 - IPMI IP: 10.30.50.78
1263 - Host IP: 10.30.51.78
1265 - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1266 - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1267 - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1268 - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1269 - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1270 - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1271 - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1272 - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1273 - ServerF1 [Server-Type-F1]:
1274 - testbedname: testbed38.
1275 - hostname: s79-t38-sut2.
1276 - IPMI IP: 10.30.50.79
1277 - Host IP: 10.30.51.79
1279 - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1280 - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1281 - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1282 - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1283 - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1284 - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1285 - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1286 - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1287 - ServerF3 [Server-Type-F3]:
1288 - testbedname: testbed38.
1289 - hostname: s80-t38-tg1.
1290 - IPMI IP: 10.30.50.80
1291 - Host IP: 10.30.51.80
1293 - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1294 - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1295 - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1296 - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1297 - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1298 - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1299 - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1300 - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1303 #### 3-Node-SnowRidge Servers (3n-snr) PROD
1306 - ServerG1 [Server-Type-G1]:
1307 - testbedname: testbed39.
1308 - hostname: s93-t39-sut1.
1309 - IPMI IP: 10.30.50.93
1310 - Host IP: 10.30.51.93
1312 - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1313 - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1314 - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
1315 - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
1316 - ServerG1 [Server-Type-G1]:
1317 - testbedname: testbed39.
1318 - hostname: s94-t39-sut2.
1319 - IPMI IP: 10.30.50.94
1320 - Host IP: 10.30.51.94
1322 - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1323 - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1324 - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1325 - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1326 - ServerF4 [Server-Type-F4]:
1327 - testbedname: testbed39.
1328 - hostname: s89-t39t310-tg1.
1329 - IPMI IP: 10.30.50.89
1330 - Host IP: 10.30.51.89
1332 - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1333 - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1334 - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1335 - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1338 #### 2-Node-SapphireRapids Servers (2n-spr) PROD
1341 - SUT [Server-Type-H1]:
1342 - testbedname: testbed21.
1343 - hostname: s52-t21-sut1.
1344 - IPMI IP: 10.30.50.52
1345 - Host IP: 10.30.51.52
1347 - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1348 - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1349 - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
1350 - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
1351 - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
1352 - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
1353 - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1354 - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1355 - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
1356 - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
1357 - s52-t21-sut1-c11/p1 - 200GE-port1 ConnectX7-2p200GE.
1358 - s52-t21-sut1-c11/p2 - 200GE-port2 ConnectX7-2p200GE.
1359 - TG [Server-Type-H2]:
1360 - testbedname: testbed21.
1361 - hostname: s53-t21-tg1.
1362 - IPMI IP: 10.30.50.53
1363 - Host IP: 10.30.51.53
1365 - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1366 - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1367 - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
1368 - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
1369 - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
1370 - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
1371 - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1372 - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1373 - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
1374 - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
1375 - SUT [Server-Type-H3]:
1376 - testbedname: testbed22.
1377 - hostname: s54-t22-sut1.
1378 - IPMI IP: 10.30.50.54
1379 - Host IP: 10.30.51.54
1381 - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1382 - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1383 - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1384 - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1385 - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1386 - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1387 - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1388 - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1389 - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1390 - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1391 - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1392 - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1393 - TG [Server-Type-H4]:
1394 - testbedname: testbed22.
1395 - hostname: s55-t22-tg1.
1396 - IPMI IP: 10.30.50.55
1397 - Host IP: 10.30.51.55
1399 - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1400 - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1401 - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1402 - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1403 - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1404 - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1405 - SUT [Server-Type-H5]:
1406 - testbedname: testbed23.
1407 - hostname: s56-t23-sut1.
1408 - IPMI IP: 10.30.50.56
1409 - Host IP: 10.30.51.56
1411 - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1412 - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1413 - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1414 - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1415 - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1416 - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1417 - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1418 - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1419 - TG [Server-Type-H6]:
1420 - testbedname: testbed23.
1421 - hostname: s57-t23-tg1.
1422 - IPMI IP: 10.30.50.57
1423 - Host IP: 10.30.51.57
1425 - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1426 - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1427 - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1428 - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1429 - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1430 - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1431 - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1432 - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1433 - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1434 - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1435 - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1436 - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1437 - SUT [Server-Type-H5]:
1438 - testbedname: testbed24.
1439 - hostname: s58-t24-sut1.
1440 - IPMI IP: 10.30.50.58
1441 - Host IP: 10.30.51.58
1443 - s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1444 - s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1445 - s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1446 - s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1447 - s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1448 - s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1449 - s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1450 - s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1451 - TG [Server-Type-H6]:
1452 - testbedname: testbed24.
1453 - hostname: s59-t24-tg1.
1454 - IPMI IP: 10.30.50.59
1455 - Host IP: 10.30.51.59
1457 - s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1458 - s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1459 - s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1460 - s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1461 - s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1462 - s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1463 - s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1464 - s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1465 - s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1466 - s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1467 - s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1468 - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1471 ### Per Testbed Wiring
1473 #### 1-Node-Skylake Wiring (1n-skx) PROD
1477 - ring1 10GE-ports x710-4p10GE:
1478 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1479 - ring2 10GE-ports x710-4p10GE:
1480 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1481 - ring3 10GE-ports x710-4p10GE:
1482 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1483 - ring4 10GE-ports x710-4p10GE:
1484 - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1485 - ring5 100GE-ports e810-2p100GE:
1486 - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1487 - ring6 100GE-ports e810-2p100GE:
1488 - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1490 - ring1 10GE-ports x710-4p10GE:
1491 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1492 - ring2 10GE-ports x710-4p10GE:
1493 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1494 - ring3 10GE-ports x710-4p10GE:
1495 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1496 - ring4 10GE-ports x710-4p10GE:
1497 - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1498 - ring5 100GE-ports e810-2p100GE:
1499 - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1500 - ring6 100GE-ports e810-2p100GE:
1501 - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1504 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1508 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1509 - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1510 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1511 - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1512 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1513 - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1514 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1515 - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1518 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1519 - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1520 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1521 - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1522 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1523 - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1524 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1525 - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1528 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1532 - link1 10GE-port x710-4p10GE on SUT:
1533 - t25-tg1-p1 to t25-sut1-c2/p1.
1534 - link2 10GE-port x710-4p10GE on SUT:
1535 - t25-tg1-p2 to t25-sut1-c2/p2.
1536 - link3 10GE-port x710-4p10GE on SUT:
1537 - t25-tg1-p3 to t25-sut1-c2/p3.
1538 - link4 10GE-port x710-4p10GE on SUT:
1539 - t25-tg1-p4 to t25-sut1-c2/p4.
1542 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1546 - ring1 10GE-ports x710-4p10GE on SUT:
1547 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1548 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1549 - ring2 10GE-ports x710-4p10GE on SUT:
1550 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1551 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1552 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1553 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1554 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1555 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1556 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1557 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1558 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1559 - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1560 - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1561 - ring6 100GE-ports e810-2p100GE on TG:
1562 - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
1563 - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
1565 - ring1 10GE-ports x710-4p10GE on SUT:
1566 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1567 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1568 - ring2 10GE-ports x710-4p10GE on SUT:
1569 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1570 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1571 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1572 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1573 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1574 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1575 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1576 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1577 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1578 - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1579 - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1580 - ring6 100GE-ports e810-2p100GE on TG:
1581 - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
1582 - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
1584 - ring1 10GE-ports x710-4p10GE on SUT:
1585 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1586 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1587 - ring2 10GE-ports x710-4p10GE on SUT:
1588 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1589 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1590 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1591 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1592 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1593 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1594 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1595 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1596 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1597 - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1598 - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1601 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1605 - ring1 10GE-ports x710-4p10GE on SUT:
1606 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1607 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1608 - ring2 10GE-ports x710-4p10GE on SUT:
1609 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1610 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1611 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1612 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1613 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1614 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1615 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1616 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1619 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
1623 - ring1 10GE-ports x520-2p10GE on SUTs:
1624 - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
1625 - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
1628 #### 2-Node-Icelake Wiring (2n-icx) PROD
1632 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1633 - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
1634 - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
1635 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1636 - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
1637 - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
1638 - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
1639 - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
1640 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1641 - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
1642 - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
1643 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1644 - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
1645 - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
1647 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1648 - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
1649 - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
1650 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1651 - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
1652 - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
1653 - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
1654 - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
1655 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1656 - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
1657 - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
1658 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1659 - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
1660 - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
1662 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1663 - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
1664 - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
1665 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1666 - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
1667 - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
1668 - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
1669 - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
1670 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1671 - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
1672 - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
1673 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1674 - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
1675 - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
1677 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1678 - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
1679 - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
1680 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1681 - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
1682 - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
1683 - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
1684 - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
1685 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1686 - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
1687 - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
1688 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1689 - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
1690 - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
1693 #### 3-Node-Rangeley Wiring (3n-rng) VERIFY
1699 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1703 - ring1 10GE-ports x520-2p10GE on SUTs:
1704 - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1705 - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1706 - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
1707 - ring2 25GE-ports cx4-2p25GE on SUTs:
1708 - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1709 - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1710 - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
1713 #### 3-Node-Altra Wiring (3n-alt) PROD
1717 - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
1718 - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
1719 - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
1720 - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
1723 #### 3-Node-Icelake Wiring (3n-icx) PROD
1727 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
1728 - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
1729 - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
1730 - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
1731 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
1732 - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
1733 - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
1734 - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
1735 - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
1736 - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
1737 - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
1738 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
1739 - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
1740 - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
1741 - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
1743 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
1744 - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
1745 - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
1746 - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
1747 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
1748 - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
1749 - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
1750 - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
1751 - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
1752 - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
1753 - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
1754 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
1755 - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
1756 - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
1757 - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
1760 #### 3-Node-SnowRidge Wiring (3n-snr) PROD
1764 - ring1 25GE-ports e810-XXVDA4-4p25GE:
1765 - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
1766 - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
1767 - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
1768 - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
1769 - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
1770 - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
1773 #### 2-Node-SapphireRapids Wiring (2n-spr) PROD
1777 - ring1 200GE-ports ConnectX7-2p200GE:
1778 - s52-t21-tg1-c2/p1 to s53-t21-sut1-c2/p1
1779 - s52-t21-tg1-c7/p1 to s53-t21-sut1-c7/p1
1780 - s53-t21-sut1-c4/p2 to s53-t21-sut1-c9/p2
1781 - ring2 200GE-ports ConnectX7-2p200GE:
1782 - s52-t21-tg1-c2/p2 to s53-t21-sut1-c2/p2
1783 - s52-t21-tg1-c7/p2 to s53-t21-sut1-c7/p2
1784 - s53-t21-sut1-c10/p1 to s53-t21-sut1-c11/p1
1785 - ring3 200GE-ports ConnectX7-2p200GE:
1786 - s52-t21-tg1-c4/p1 to s53-t21-sut1-c4/p1
1787 - s52-t21-tg1-c9/p1 to s53-t21-sut1-c9/p1
1788 - s53-t21-sut1-c10/p2 to s53-t21-sut1-c11/p2
1790 - ring1 100GE-ports e810-2CQDA2-2p100GE:
1791 - s54-t22-tg1-c2/p1 to s55-t22-sut1-c2/p1
1792 - s54-t22-tg1-c2/p2 to s55-t22-sut1-c7/p1
1793 - s54-t22-sut1-c2/p2 to s55-t22-sut1-c7/p2
1794 - ring2 25GE-ports e810-XXVDA4-4p25GE:
1795 - s54-t22-tg1-c4/p1 to s55-t22-sut1-c4/p1
1796 - s54-t22-tg1-c4/p2 to s55-t22-sut1-c9/p1
1797 - s54-t22-sut1-c4/p2 to s55-t22-sut1-c9/p2
1799 - ring1 200GE-ports ConnectX7-2p200GE:
1800 - s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1.
1801 - s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2.
1802 - ring2 100GE-ports e810-2CQDA2-2p100GE:
1803 - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1.
1804 - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2.
1805 - ring3 25GE-ports e810-XXVDA4-2p25GE:
1806 - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1.
1807 - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2.
1808 - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3.
1809 - s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4.
1810 - ring4 200GE-ports ConnectX7-2p200GE:
1811 - s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2.
1812 - ring5 100GE-ports e810-2CQDA2-2p100GE:
1813 - s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2.
1815 - ring1 200GE-ports ConnectX7-2p200GE:
1816 - s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1.
1817 - s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2.
1818 - ring2 100GE-ports e810-2CQDA2-2p100GE:
1819 - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1.
1820 - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2.
1821 - ring3 25GE-ports e810-XXVDA4-2p25GE:
1822 - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1.
1823 - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2.
1824 - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3.
1825 - s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4.
1826 - ring4 200GE-ports ConnectX7-2p200GE:
1827 - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2.
1828 - ring5 100GE-ports e810-2CQDA2-2p100GE:
1829 - s59-t24-tg1-c9/p1 to s59-t24-tg1-c9/p2.