1 ---
2 bookToc: true
3 title: "FD.io DC Testbed Specifications"
4 weight: 2
5 ---
6
7 # FD.io DC Testbed Specifications
8
9 ## Purpose
10
11 This note includes specification of the physical testbed infrastructure
12 hosted by LFN FD.io CSIT project.
13
14 ## Server Management
15
16 ### Addressing
17
18 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
19 Management port, which are connected to two different VLANs.
20
21 #### LOM (IPMI) VLAN
22
23    - Subnet: 10.30.50.0/24
24    - Gateway: 10.30.50.1
25    - Broadcast: 10.30.50.255
26    - DNS1: 199.204.44.24
27    - DNS2: 199.204.47.54
28
29 #### Management VLAN
30    - Subnet: 10.30.51.0/24
31    - Gateway: 10.30.51.1
32    - Broadcast: 10.30.51.255
33    - DNS1: 199.204.44.24
34    - DNS2: 199.204.47.54
35
36 To access these hosts, VPN connection is required.
37
38 ## Testbeds Overview
39
40 ### Summary List
41
42 ```
43  #. Type                 Purpose  SUT   TG    #TB  #SUT #TG  #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr
44  1. 1-Node-Skylake         nomad  skx   na    5    5    0    5    0    0    0    0    0    0    0    0    0    0
45  2. 1-Node-Cascadelake     nomad  clx   na    1    1    0    0    0    0    0    0    0    1    0    0    0    0
46  3. 1-Node-AmpereAltra     nomad  alt   na    2    2    0    0    0    0    0    0    2    0    0    0    0    0
47  4. 2-Node-IxiaPS1L47      tcp    skx   ps1   1    1    1    1    1    0    0    0    0    0    0    0    0    0
48  5. 2-Node-Cascadelake     perf   clx   clx   3    3    3    0    0    0    0    0    0    6    0    0    0    0
49  6. 2-Node-ThunderX2       perf   tx2   skx   1    1    .5   .5   0    0    1    0    0    0    0    0    0    0
50  7. 2-Node-Icelake         perf   icx   icx   4    4    4    0    0    0    0    0    0    0    0    8    0    0
51  8. 3-Node-Rangeley        perf   rng   skx   1    3    1    0    0    2    0    0    0    0    0    0    0    0
52  9. 3-Node-Taishan         perf   tsh   skx   1    2    .5   .5   0    0    0    2    0    0    0    0    0    0
53 10. 3-Node-Altra           perf   alt   icx   1    2    1    0    0    0    0    0    2    0    0    1    0    0
54 11. 2-Node-Zen2            perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    2    0    0    0
55 12. 3-Node-Icelake         perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    6    0    0
56 13. 3-Node-SnowRidge       perf   snr   icx   1    2    .5   0    0    0    0    0    0    0    0    .5   2    0
57 13. 2-Node-SapphireRapids  perf   spr   spr   4    4    4    0    0    0    0    0    0    0    0    0    0    8
58                                      Totals: 28   35  18.5   7    1    2    1    2    4    7    2   15.5  2    8
59 ```
60
61 ### 1-Node-Skylake Xeon Intel (1n-skx)
62
63 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
64 ports connected back-to-back ([Server Types](#server-types)).
65 Used for FD.io VPP_Device functional driver tests.
66
67 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
68
69 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
70 ports connected back-to-back ([Server Types](#server-types)).
71 Used for FD.io VPP_Device functional driver tests.
72
73 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
74
75 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
76 NIC ports connected back-to-back ([Server Types](#server-types)).
77
78 Used for FD.io VPP_Device functional driver tests.
79
80 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
81
82 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
83 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
84 circular topology ([Server Types](#server-types)).
85 Used for FD.io TCP/IP and HTTP performance tests.
86
87 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
88
89 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
90 one TG (Server-Type-C3) connected in a 2-node circular topology
91 ([Server Types](#server-types)).
92 Used for FD.io performance tests.
93
94 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
95
96 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
97 one TG (Server-Type-D2) connected in a 2-node circular topology
98 ([Server Types](#server-types)).
99 Used for FD.io performance tests.
100
101 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
102
103 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
104 one TG (Server-Type-E31) connected in a 2-node circular topology
105 ([Server Types](#server-types)).
106 Used for FD.io performance tests.
107
108 ### 2-Node-Icelake Xeon Intel (2n-icx)
109
110 Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
111 one TG (Server-Type-F2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
114
115 ### 3-Node-Rangeley Atom Testbeds
116
117 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
118 TG (Server-Type-2) connected in a 3-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
121
122 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
123
124 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
125 TG (Server-Type-E31) connected in a 3-node circular topology
126 ([Server Types](#server-types)).
127 Used for FD.io performance tests.
128
129 ### 3-Node-Altra Arm Ampere (3n-alt)
130
131 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
132 TG (Server-Type-E32) connected in a 3-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
135
136 ### 3-Node-Icelake Xeon Intel (3n-icx)
137
138 Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F3) and one
139 TG (Server-Type-F3) connected in a 3-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
142
143 ### 3-Node-SnowRidge Atom Intel (3n-snr)
144
145 Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
146 TG (Server-Type-F5) connected in a 3-node circular topology
147 ([Server Types](#server-types)).
148 Used for FD.io performance tests.
149
150 ### 2-Node-SapphireRapids Xeon Intel (2n-spr)
151
152 Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and
153 one TG (Server-Type-H6) connected in a 2-node or 3-node circular topology
154 ([Server Types](#server-types)).
155 Used for FD.io performance tests.
156
157
158 ## Tesdtbed Naming Convention
159
160 Following naming convention is used within this page to specify physical
161 connectivity and wiring across defined CSIT testbeds:
162
163 - **testbedname**: testbedN.
164 - **hostname**:
165     - traffic-generator: tN-tgW.
166     - system-under-testX: tN-sutX.
167 - **portnames**:
168     - tN-tgW-cY/pZ.
169     - tN-sutX-cY/pZ.
170 - **where**:
171     - N - testbed number.
172     - tgW - server acts as traffic-generator with W index.
173     - sutX - server acts as system-under-test with X index.
174     - Y - PCIe slot number denoting a NIC card number within the host.
175     - Z - port number on the NIC card.
176
177 ## Server Types
178
179 FD.io CSIT lab contains following server types:
180
181 1. **Server-Type-B2**: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
182     - Quantity: 2
183     - Physical connectivity:
184         - IPMI and host management ports.
185     - Main HW configuration:
186         - Chassis: SuperMicro SYS-7049GP-TRT.
187         - Motherboard: SuperMicro X11DPG-QT.
188         - Processors: 2* Intel Platinum 8180 2.5 GHz.
189         - RAM Memory: 16* 16GB DDR4-2666MHz.
190         - Disks: 2* 1.6TB 6G SATA SSD.
191     - NICs configuration:
192         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
193             - PCIe Slot2 18:00.xx: empty.
194             - PCIe Slot4 3b:00.xx: empty.
195             - PCIe Slot9 5e:00.xx: empty.
196         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
197             - PCIe Slot6 86:00.xx: empty.
198             - PCIe Slot8 af:00.xx: empty.
199             - PCIe Slot10 d8:00.xx: empty.
200
201 2. **Server-Type-B6**: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
202     - Quantity: 2.
203     - Physical connectivity:
204         - IPMI and host management ports.
205         - NIC ports connected into 1-node topologies.
206     - Main HW configuration:
207         - Chassis: SuperMicro SYS-7049GP-TRT.
208         - Motherboard: SuperMicro X11DPG-QT.
209         - Processors: 2* Intel Platinum 8180 2.5 GHz.
210         - RAM Memory: 16* 16GB DDR4-2666MHz.
211         - Disks: 2* 1.6TB 6G SATA SSD.
212     - NICs configuration:
213         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
214             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
215             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
216             - PCIe Slot9 5e:00.xx: empty.
217         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
218             - PCIe Slot6 86:00.xx: empty.
219             - PCIe Slot8 af:00.xx: empty.
220             - PCIe Slot10 d8:00.xx: empty.
221
222 3. **Server-Type-B7**: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
223     - Quantity: 1.
224     - Physical connectivity:
225         - Host management interface: 10/100/1000-BaseT.
226         - 8-port 10GE SFP+ integrated NIC.
227     - Main HW configuration:
228         - Chassis: PS10GE4NG.
229         - Motherboard: SuperMicro X11DPG-QT.
230         - Processors: Quad-Core, Intel Processor.
231         - HW accelerators: FPGA offload.
232         - RAM Memory: 64GB.
233         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
234         - Physical Interfaces: 4 * 10GE SFP+.
235         - Operating System: Native IxOS.
236     - Interface configuration:
237         - Port-1: 10GE SFP+.
238         - Port-2: 10GE SFP+.
239         - Port-3: 10GE SFP+.
240         - Port-4: 10GE SFP+.
241
242 4. **Server-Type-B8**: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
243     - Quantity: 1.
244     - Physical connectivity:
245         - IPMI and host management ports.
246         - NIC ports.
247     - Main HW configuration:
248         - Chassis: SuperMicro SYS-7049GP-TRT.
249         - Motherboard: SuperMicro X11DPG-QT.
250         - Processors: 2* Intel Platinum 8180 2.5 GHz.
251         - RAM Memory: 16* 16GB DDR4-2666MHz.
252         - Disks: 2* 1.6TB 6G SATA SSD.
253     - NICs configuration:
254         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
255             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
256             - PCIe Slot4 3b:00.xx: empty.
257             - PCIe Slot9 5e:00.xx: empty.
258         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
259             - PCIe Slot6 86:00.xx: empty.
260             - PCIe Slot8 af:00.xx: empty.
261             - PCIe Slot10 d8:00.xx: empty.
262 5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
263     - Quantity: 1.
264     - Physical connectivity:
265         - IPMI and host management ports.
266         - NIC ports connected into 1-node testbed topologies.
267     - Main HW configuration:
268         - Chassis: SuperMicro SYS-7049GP-TRT.
269         - Motherboard: SuperMicro X11DPG-QT.
270         - Processors: 2* Intel Platinum 8280 2.7 GHz.
271         - RAM Memory: 12* 16GB DDR4-2933.
272         - Disks: 2* 1.92TB SATA SSD.
273     - NICs configuration:
274         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
275             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
276             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
277             - PCIe Slot9 5e:00.xx: empty.
278         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
279             - PCIe Slot6 86:00.xx: empty.
280             - PCIe Slot8 af:00.xx: empty.
281             - PCIe Slot10 d8:00.xx: empty.
282
283 6. **Server-Type-C2**: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
284     - Quantity: 3
285     - Physical connectivity:
286         - IPMI and host management ports.
287         - NIC ports connected into 2-node testbed topologies.
288     - Main HW configuration:
289         - Chassis: SuperMicro SYS-7049GP-TRT.
290         - Motherboard: SuperMicro X11DPG-QT.
291         - Processors: 2* Intel Gold 6252N 2.3 GHz.
292         - RAM Memory: 12* 16GB DDR4-2933.
293         - Disks: 2* 1.92TB SATA SSD.
294     - NICs configuration:
295         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
296             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
297             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
298             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
299         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
300             - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
301             - PCIe Slot8 af:00.xx: empty.
302             - PCIe Slot10 d8:00.xx: empty.
303
304 7. **Server-Type-C3**: Purpose - Cascadelake Xeon TG for FD.io performance testing.
305     - Quantity: 3.
306     - Physical connectivity:
307         - IPMI and host management ports.
308         - NIC ports connected into 2-node testbed topologies.
309     - Main HW configuration:
310         - Chassis: SuperMicro SYS-7049GP-TRT.
311         - Motherboard: SuperMicro X11DPG-QT.
312         - Processors: 2* Intel Platinum 8280 2.7 GHz.
313         - RAM Memory: 12* 16GB DDR4-2933.
314         - Disks: 2* 1.92TB SATA SSD.
315     - NICs configuration:
316         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
317             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
318             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
319             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
320         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
321             - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
322             - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
323             - PCIe Slot10 d8:00.xx: empty.
324
325 8. **Server-Type-C4**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
326     - Quantity: 3.
327     - Physical connectivity:
328         - IPMI and host management ports.
329         - no NIC ports, standalone setup.
330     - Main HW configuration:
331         - Chassis: SuperMicro 1029P-WTRT.
332         - Motherboard: SuperMicro X11DDW-NT.
333         - Processors: 2* Intel Platinum 8280 2.7 GHz.
334         - RAM Memory: 12* 16GB DDR4-2933.
335         - Disks: 4* 1.92TB SATA SSD.
336     - NICs configuration:
337         - Numa0:
338             - no cards.
339         - Numa1:
340             - no cards.
341
342 9. **Server-Type-D1**: Purpose - Zen2 EPYC SUT for FD.io performance testing.
343     - Quantity: 1.
344     - Physical connectivity:
345         - IPMI and host management ports.
346         - NIC ports connected into 2-node testbed topologies.
347     - Main HW configuration:
348         - Chassis: SuperMicro AS-1114S-WTRT
349         - Processors: 1* AMD EPYC 7532 2.4 GHz.
350         - RAM Memory: 8* 32GB DDR4-2933.
351         - Disks: 1* 1TB SATA SSD.
352     - NICs configuration:
353         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
354             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
355             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
356             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
357
358 10. **Server-Type-D2**: Purpose - Zen2 EPYC TG for FD.io performance testing.
359     - Quantity: 1.
360     - Physical connectivity:
361         - IPMI and host management ports.
362         - NIC ports connected into 2-node testbed topologies.
363     - Main HW configuration:
364         - Chassis: SuperMicro AS-1114S-WTRT
365         - Processors: 1* AMD EPYC 7532 2.4 GHz.
366         - RAM Memory: 8* 32GB DDR4-2933.
367         - Disks: 1* 1TB SATA SSD.
368     - NICs configuration:
369         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
370             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
371             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
372             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
373
374 11. **Server-Type-E11**: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
375     - Quantity: 2.
376     - Physical connectivity:
377         - IPMI and host management ports.
378         - NIC ports connected into 1-node topologies.
379     - Main HW configuration:
380         - Chassis: GIGABYTE Rack Mount
381         - Motherboard: MT91-FS4-00
382         - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
383         - RAM Memory: 16 * 16GB DIMM
384         - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
385     - NICs configuration:
386         - Numa0:
387             - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
388             - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
389         - Numa1:
390             - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
391             - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
392
393 12. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
394     - Quantity: 2.
395     - Physical connectivity:
396         - IPMI(?) and host management ports.
397         - NIC ports connected into 3-node topology.
398     - Main HW configuration:
399         - Chassis: Huawei TaiShan 2280.
400         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
401         - RAM Memory: 8* 16GB DDR4-2400MT/s
402         - Disks: 1* 4TB SATA HDD
403     - NICs configuration:
404         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
405         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
406
407 13. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
408     - Quantity: 1.
409     - Physical connectivity:
410         - IPMI and host management ports.
411         - NIC ports connected into 2-node topologies.
412     - Main HW configuration:
413         - Chassis: Gigabyte R181-T90 1U
414         - Motherboard: MT91-FS1
415         - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
416         - RAM Memory: 4* 32GB RDIMM
417         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
418     - NICs configuration:
419         - Numa0:
420             - no cards
421         - Numa1:
422             - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
423
424 14. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
425     - Quantity: 2.
426     - Physical connectivity:
427         - IPMI and host management ports.
428         - NIC ports connected into 3-node topologies.
429     - Main HW configuration:
430         - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
431         - Motherboard: Mt.Jade Motherboard
432         - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
433         - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
434         - RAM Memory: 16* 8GB DDR4-3200MT/s
435         - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
436     - NICs configuration:
437         - Numa0: (x16, x16 PCIe4.0 lanes)
438             - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
439             - PCIe Slot8 0001:00:00.x: ConnectX6-2p100GE Mellanox.
440         - Numa1:
441             - no cards.
442
443 15. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build.
444     - Quantity: 2.
445     - Physical connectivity:
446         - IPMI and host management ports.
447     - Main HW configuration:
448         - Chassis: Gigabyte R152-P30-00 1U
449         - Motherboard: MP32-AR1-00
450         - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
451         - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
452         - RAM Memory: 12* 16GB DDR4-3200MT/s
453         - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
454
455 16. **Server-Type-E31**: Purpose - Skylake Xeon Shared TG for FD.io performance testing.
456     - Quantity: 1.
457     - Physical connectivity:
458         - IPMI and host management ports.
459         - NIC ports connected into 2-node and 3-node topologies.
460     - Main HW configuration:
461         - Chassis: SuperMicro SYS-7049GP-TRT.
462         - Motherboard: SuperMicro X11DPG-QT.
463         - Processors: 2* Intel Platinum 8180 2.5 GHz.
464         - RAM Memory: 16* 16GB DDR4-2666MHz.
465         - Disks: 2* 1.6TB 6G SATA SSD.
466     - NICs configuration:
467         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
468             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
469             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
470             - PCIe Slot9 5e:00.xx: empty.
471         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
472             - PCIe Slot6 86:00.xx: empty.
473             - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
474             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
475
476 17. **Server-Type-E32**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
477     - Quantity: 1.
478     - Physical connectivity:
479         - IPMI and host management ports.
480         - NIC ports connected into 2-node and/or 3-node testbed topologies.
481     - Main HW configuration:
482         - Chassis: SuperMicro SYS-740GP-TNRT.
483         - Motherboard: Super X12DPG-QT6.
484         - Processors: 2* Intel Platinum 8358 2.6 GHz.
485         - RAM Memory: 16* 16GB DDR4-3200.
486         - Disks: 2* 960GB SATA SSD.
487     - NICs configuration:
488         - Numa0: (x16, x16, x16 PCIe4.0 lanes)
489             - PCIe Slot2 4b:00.xx: xxv710-DA2-2p25GE Intel.
490             - PCIe Slot4 31:00.xx: xl710-QDA2-2p40GE Intel.
491             - PCIe Slot9 ff:00.xx: empty.
492         - Numa1: (x16, x16, x16 PCIe4.0 lanes)
493             - PCIe Slot6 ca:00.xx: e810-XXVDA4-4p25GE Intel.
494             - PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
495             - PCIe Slot10 ff:00.xx: empty.
496
497 18. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing.
498     - Quantity: 4.
499     - Physical connectivity:
500         - IPMI and host management ports.
501         - NIC ports connected into 2-node topology.
502     - Main HW configuration:
503         - Chassis: SuperMicro SYS-740GP-TNRT.
504         - Motherboard: Super X12DPG-QT6.
505         - Processors: 2* Intel Platinum 8358 2.6 GHz.
506         - RAM Memory: 16* 16GB DDR4-3200.
507         - Disks: 2* 960GB SATA SSD.
508     - NICs configuration:
509         - Numa0: (x16, x16, x16 PCIe4.0 lanes)
510             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
511             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
512             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
513         - Numa1: (x16, x16, x16 PCIe4.0 lanes)
514             - PCIe Slot6 86:00.xx: empty.
515             - PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox.
516             - PCIe Slot10 d8:00.xx: empty.
517
518 19. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing.
519     - Quantity: 4.
520     - Physical connectivity:
521         - IPMI and host management ports.
522         - NIC ports connected into 2-node testbed topologies.
523     - Main HW configuration:
524         - Chassis: SuperMicro SYS-740GP-TNRT.
525         - Motherboard: Super X12DPG-QT6.
526         - Processors: 2* Intel Platinum 8358 2.6 GHz.
527         - RAM Memory: 16* 16GB DDR4-3200.
528         - Disks: 2* 960GB SATA SSD.
529     - NICs configuration:
530         - Numa0: (x16, x16, x16 PCIe4.0 lanes)
531             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
532             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
533             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
534         - Numa1: (x16, x16, x16 PCIe4.0 lanes)
535             - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
536             - PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox.
537             - PCIe Slot10 d8:00.xx: empty.
538
539 20. **Server-Type-F3**: Purpose - Icelake Xeon TG or SUT for FD.io performance testing.
540     - Quantity: 6.
541     - Physical connectivity:
542         - IPMI and host management ports.
543         - NIC ports connected into 3-node testbed topologies.
544     - Main HW configuration:
545         - Chassis: SuperMicro SYS-740GP-TNRT.
546         - Motherboard: Super X12DPG-QT6.
547         - Processors: 2* Intel Platinum 8358 2.6 GHz.
548         - RAM Memory: 16* 16GB DDR4-3200.
549         - Disks: 2* 960GB SATA SSD.
550     - NICs configuration:
551         - Numa0: (x16, x16, x16 PCIe4.0 lanes)
552             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
553             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
554             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
555         - Numa1: (x16, x16, x16 PCIe4.0 lanes)
556             - PCIe Slot6 86:00.xx: ConnectX6-2p100GE Mellanox.
557             - PCIe Slot8 af:00.xx: empty.
558             - PCIe Slot10 d8:00.xx: empty.
559
560 21. **Server-Type-F4**: Purpose - Icelake Xeon TG for FD.io performance testing.
561     - Quantity: 3.
562     - Physical connectivity:
563         - IPMI and host management ports.
564         - NIC ports connected into 3-node testbed topologies.
565     - Main HW configuration:
566         - Chassis: SuperMicro SYS-740GP-TNRT.
567         - Motherboard: Super X12DPG-QT6.
568         - Processors: 2* Intel Platinum 8358 2.6 GHz.
569         - RAM Memory: 16* 16GB DDR4-3200.
570         - Disks: 2* 960GB SATA SSD.
571     - NICs configuration:
572         - Numa0: (x16, x16, x16 PCIe4.0 lanes)
573             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
574             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
575             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
576         - Numa1: (x16, x16, x16 PCIe4.0 lanes)
577             - PCIe Slot6 86:00.xx: ConnectX6-2p100GE Mellanox.
578             - PCIe Slot8 af:00.xx: empty.
579             - PCIe Slot10 d8:00.xx: empty.
580
581 22. **Server-Type-F5**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
582     - Quantity: 2.
583     - Physical connectivity:
584         - IPMI and host management ports.
585         - NIC ports connected into 2-node and/or 3-node testbed topologies.
586     - Main HW configuration:
587         - Chassis: SuperMicro SYS-740GP-TNRT.
588         - Motherboard: Super X12DPG-QT6.
589         - Processors: 2* Intel Platinum 8358 2.6 GHz.
590         - RAM Memory: 16* 16GB DDR4-3200.
591         - Disks: 2* 960GB SATA SSD.
592     - NICs configuration:
593         - Numa0: (x16, x16, x16 PCIe4.0 lanes)
594             - PCIe Slot2 4b:00.xx: xxv710-DA2-2p25GE Intel.
595             - PCIe Slot4 31:00.xx: empty.
596             - PCIe Slot9 ff:00.xx: empty.
597         - Numa1: (x16, x16, x16 PCIe4.0 lanes)
598             - PCIe Slot6 ca:00.xx: e810-XXVDA4-4p25GE Intel.
599             - PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
600             - PCIe Slot10 ff:00.xx: empty.
601
602 23. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing.
603     - Quantity: 2
604     - Physical connectivity:
605         - IPMI and host management ports.
606         - NIC ports connected into 3-node testbed topology.
607     - Main HW configuration:
608         - Chassis: Intel JACOBSVILLE SDP.
609         - Motherboard: Intel JACOBSVILLE E63448-400.
610         - Processors: 1* Intel Atom P5362B 2.2 GHz.
611         - RAM Memory: 2* 16GB DDR4-2933.
612         - Disks: ?* ? SATA SSD.
613     - NICs configuration:
614         - Numa0: (x16, PCIe3.0 lane)
615             - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
616
617 24. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
618     - Quantity: 1.
619     - Physical connectivity:
620         - IPMI and host management ports.
621         - NIC ports connected into 3-numa-node testbed topologies.
622     - Main HW configuration:
623         - Chassis: SuperMicro SYS-741GE-TNRT.
624         - Motherboard: Super X13DEG-QT-P.
625         - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
626         - RAM Memory: 16* 32GB DDR5-4800.
627         - Disks: 2* 960GB SATA SSD.
628     - NICs configuration:
629         - Numa0: (x16, x16, x16 PCIe5.0 lanes)
630             - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
631             - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
632             - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
633         - Numa1: (x16, x16, x16 PCIe5.0 lanes)
634             - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
635             - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
636             - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
637
638 25. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
639     - Quantity: 1.
640     - Physical connectivity:
641         - IPMI and host management ports.
642         - NIC ports connected into 3-numa-node testbed topologies.
643     - Main HW configuration:
644         - Chassis: SuperMicro SYS-741GE-TNRT.
645         - Motherboard: Super X13DEG-QT-P.
646         - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
647         - RAM Memory: 16* 32GB DDR5-4800.
648         - Disks: 2* 960GB SATA SSD.
649     - NICs configuration:
650         - Numa0: (x16, x16, x16 PCIe5.0 lanes)
651             - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
652             - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
653             - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
654         - Numa1: (x16, x16, x16 PCIe5.0 lanes)
655             - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
656             - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
657             - PCIe Slot11 d8:00.xx: empty.
658
659 26. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
660     - Quantity: 1.
661     - Physical connectivity:
662         - IPMI and host management ports.
663         - NIC ports connected into 3-numa-node testbed topologies.
664     - Main HW configuration:
665         - Chassis: SuperMicro SYS-741GE-TNRT.
666         - Motherboard: Super X13DEG-QT-P.
667         - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
668         - RAM Memory: 16* 32GB DDR5-4800.
669         - Disks: 2* 960GB SATA SSD.
670     - NICs configuration:
671         - Numa0: (x16, x16, x16 PCIe5.0 lanes)
672             - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
673             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
674             - PCIe Slot10 5e:00.xx: empty.
675         - Numa1: (x16, x16, x16 PCIe5.0 lanes)
676             - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel.
677             - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
678             - PCIe Slot11 d8:00.xx: empty.
679
680 27. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
681     - Quantity: 1.
682     - Physical connectivity:
683         - IPMI and host management ports.
684         - NIC ports connected into 3-numa-node testbed topologies.
685     - Main HW configuration:
686         - Chassis: SuperMicro SYS-741GE-TNRT.
687         - Motherboard: Super X13DEG-QT-P.
688         - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
689         - RAM Memory: 16* 32GB DDR5-4800.
690         - Disks: 2* 960GB SATA SSD.
691     - NICs configuration:
692         - Numa0: (x16, x16, x16 PCIe5.0 lanes)
693             - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
694             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
695             - PCIe Slot10 5e:00.xx: empty.
696         - Numa1: (x16, x16, x16 PCIe5.0 lanes)
697             - PCIe Slot7 86:00.xx: empty.
698             - PCIe Slot9 af:00.xx: empty.
699             - PCIe Slot11 d8:00.xx: empty.
700
701 28. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
702     - Quantity: 2.
703     - Physical connectivity:
704         - IPMI and host management ports.
705         - NIC ports connected into 2-node testbed topologies.
706     - Main HW configuration:
707         - Chassis: SuperMicro SYS-741GE-TNRT.
708         - Motherboard: Super X13DEG-QT-P.
709         - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
710         - RAM Memory: 16* 32GB DDR5-4800.
711         - Disks: 2* 960GB SATA SSD.
712     - NICs configuration:
713         - Numa0: (x16, x16, x16 PCIe5.0 lanes)
714             - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
715             - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
716             - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
717         - Numa1: (x16, x16, x16 PCIe5.0 lanes)
718             - PCIe Slot7 86:00.xx: empty.
719             - PCIe Slot9 af:00.xx: empty.
720             - PCIe Slot11 d8:00.xx: empty.
721
722 29. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
723     - Quantity: 2.
724     - Physical connectivity:
725         - IPMI and host management ports.
726         - NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test.
727     - Main HW configuration:
728         - Chassis: SuperMicro SYS-741GE-TNRT.
729         - Motherboard: Super X13DEG-QT-P.
730         - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
731         - RAM Memory: 16* 32GB DDR5-4800.
732         - Disks: 2* 960GB SATA SSD.
733     - NICs configuration:
734         - Numa0: (x16, x16, x16 PCIe5.0 lanes)
735             - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
736             - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
737             - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
738         - Numa1: (x16, x16, x16 PCIe5.0 lanes)
739             - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
740             - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
741             - PCIe Slot11 d8:00.xx: empty.
742
743 ## Testbeds Configuration
744
745 ### 1-Node-Skylake (1n-skx)
746
747 ```
748 - SUT [Server-Type-B6]:
749     - testbedname: testbed11.
750     - hostname: s1-t11-sut1.
751     - IPMI IP: 10.30.50.47
752     - Host IP: 10.30.51.50
753     - portnames:
754         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
755         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
756         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
757         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
758         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
759         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
760         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
761         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
762 - SUT [Server-Type-B6]:
763     - testbedname: testbed12.
764     - hostname: s2-t12-sut1.
765     - IPMI IP: 10.30.50.48
766     - Host IP: 10.30.51.51
767     - portnames:
768         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
769         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
770         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
771         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
772         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
773         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
774         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
775         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
776 ```
777
778 ### 1-Node-ThunderX2 (1n-tx2)
779
780 ```
781 - SUT [Server-Type-E11]:
782     - testbedname: testbed13
783     - hostname: s55-t13-sut1
784     - IPMI IP: 10.30.50.70
785     - Host IP: 10.30.51.70
786     - portnames:
787         - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
788         - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
789         - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
790         - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
791         - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
792         - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
793         - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
794         - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
795 - SUT [Server-Type-E11]:
796     - testbedname: testbed14
797     - hostname: s56-t14-sut1
798     - IPMI IP: 10.30.50.71
799     - Host IP: 10.30.51.71
800     - portnames:
801         - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
802         - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
803         - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
804         - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
805         - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
806         - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
807         - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
808         - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
809 ```
810
811 ### 1-Node-Cascadelake (1n-clx)
812
813 ```
814 - SUT [Server-Type-C1]:
815     - testbedname: testbed11.
816     - hostname: s32-t14-sut1.
817     - IPMI IP: 10.30.55.17
818     - Host IP: 10.32.8.17
819     - portnames:
820         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
821         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
822         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
823         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
824         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
825         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
826         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
827         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
828 ```
829
830 ### 2-Node-IxiaPS1L47 (2n-ps1)
831
832 ```
833 - SUT [Server-Type-B8]:
834     - testbedname: testbed25.
835     - hostname: s25-t25-sut1.
836     - IPMI IP: 10.30.50.58
837     - Host IP: 10.30.51.61
838     - portnames:
839         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
840         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
841         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
842         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
843 - TG [Server-Type-B7]:
844     - testbedname: testbed25.
845     - hostname: s26-t25-tg1.
846     - IPMI IP: 10.30.50.59
847     - Host IP: 10.30.51.62
848     - portnames:
849         - s26-t25-tg1-p1 - 10GE-port1.
850         - s26-t25-tg1-p2 - 10GE-port2.
851         - s26-t25-tg1-p3 - 10GE-port3.
852         - s26-t25-tg1-p4 - 10GE-port4.
853 ```
854
855 ### 2-Node-Cascadelake (2n-clx)
856
857 {{< figure src="/cdocs/testbed-2n-clx.svg" >}}
858
859 ```
860 - SUT [Server-Type-C2]:
861     - testbedname: testbed27.
862     - hostname: s33-t27-sut1.
863     - IPMI IP: 10.30.55.18
864     - Host IP: 10.32.8.18
865     - portnames:
866         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
867         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
868         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
869         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
870         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
871         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
872         - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
873         - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
874         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
875         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
876 - TG [Server-Type-C3]:
877     - testbedname: testbed27.
878     - hostname: s34-t27-tg1.
879     - IPMI IP: 10.30.55.19
880     - Host IP: 10.32.8.19
881     - portnames:
882         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
883         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
884         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
885         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
886         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
887         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
888         - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
889         - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
890         - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
891         - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
892         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
893         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
894 - SUT [Server-Type-C2]:
895     - testbedname: testbed28.
896     - hostname: s35-t28-sut1.
897     - IPMI IP: 10.30.55.20
898     - Host IP: 10.32.8.20
899     - portnames:
900         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
901         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
902         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
903         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
904         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
905         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
906         - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
907         - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
908         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
909         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
910 - TG [Server-Type-C3]:
911     - testbedname: testbed28.
912     - hostname: s36-t28-tg1.
913     - IPMI IP: 10.30.55.21
914     - Host IP: 10.32.8.21
915     - portnames:
916         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
917         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
918         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
919         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
920         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
921         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
922         - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
923         - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
924         - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
925         - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
926         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
927         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
928 - SUT [Server-Type-C2]:
929     - testbedname: testbed29.
930     - hostname: s37-t29-sut1.
931     - IPMI IP: 10.30.55.22
932     - Host IP: 10.32.8.22
933     - portnames:
934         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
935         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
936         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
937         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
938         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
939         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
940         - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
941         - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
942         - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
943         - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
944 - TG [Server-Type-C3]:
945     - testbedname: testbed29.
946     - hostname: s38-t29-tg1.
947     - IPMI IP: 10.30.55.23
948     - Host IP: 10.32.8.23
949     - portnames:
950         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
951         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
952         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
953         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
954         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
955         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
956         - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
957         - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
958         - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
959         - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
960 ```
961
962 ### 2-Node-Zen2 (2n-zn2)
963
964 {{< figure src="/cdocs/testbed-2n-zn2.svg" >}}
965
966 ```
967 - SUT [Server-Type-D1]:
968     - testbedname: testbed210.
969     - hostname: s60-t210-sut1.
970     - IPMI IP: 10.30.55.24
971     - Host IP: 10.32.8.24
972     - portnames:
973         - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
974         - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
975         - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
976         - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
977         - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
978         - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
979         - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
980         - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
981 - TG [Server-Type-D2]:
982     - testbedname: testbed210.
983     - hostname: s61-t210-tg1.
984     - IPMI IP: 10.30.55.25
985     - Host IP: 10.32.8.25
986     - portnames:
987         - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
988         - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
989         - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
990         - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
991         - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
992         - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
993         - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
994         - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
995 ```
996
997 ### 2-Node-ThunderX2 (2x-tx2)
998
999 {{< figure src="/cdocs/testbed-2n-tx2.svg" >}}
1000
1001 ```
1002 - SUT [Server-Type-E22]:
1003     - testbedname: testbed211.
1004     - hostname: s27-t211-sut1.
1005     - IPMI IP: 10.30.50.69
1006     - Host IP: 10.30.51.69
1007     - portnames:
1008         - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1009         - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1010 - TG [Server-Type-E31]:
1011     - testbedname: testbed33 and testbed211.
1012     - hostname: s19-t33t211-tg1.
1013     - IPMI IP: 10.30.50.46
1014     - Host IP: 10.30.51.49
1015     - portnames:
1016         - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1017         - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1018         - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1019         - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1020         - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1021         - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1022         - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1023         - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1024         - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1025         - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1026         - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1027         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1028 ```
1029
1030 ### 2-Node-Icelake (2n-icx)
1031
1032 {{< figure src="/cdocs/testbed-2n-icx.svg" >}}
1033
1034 ```
1035 - SUT [Server-Type-F1]:
1036     - testbedname: testbed212.
1037     - hostname: s71-t212-sut1.
1038     - IPMI IP: 10.30.50.81
1039     - Host IP: 10.30.51.81
1040     - portnames:
1041         - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1042         - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1043         - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1044         - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1045         - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1046         - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1047         - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1048         - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1049         - s71-t212-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1050         - s71-t212-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1051 - TG [Server-Type-F2]:
1052     - testbedname: testbed212.
1053     - hostname: s72-t212-tg1.
1054     - IPMI IP: 10.30.50.82
1055     - Host IP: 10.30.51.82
1056     - portnames:
1057         - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1058         - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1059         - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1060         - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1061         - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1062         - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1063         - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1064         - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1065         - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1066         - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1067         - s72-t212-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1068         - s72-t212-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1069 - SUT [Server-Type-F1]:
1070     - testbedname: testbed213.
1071     - hostname: s83-t213-sut1.
1072     - IPMI IP: 10.30.50.83
1073     - Host IP: 10.30.51.83
1074     - portnames:
1075         - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1076         - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1077         - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1078         - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1079         - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1080         - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1081         - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1082         - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1083         - s83-t213-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1084         - s83-t213-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1085 - TG [Server-Type-F2]:
1086     - testbedname: testbed213.
1087     - hostname: s84-t213-tg1.
1088     - IPMI IP: 10.30.50.84
1089     - Host IP: 10.30.51.84
1090     - portnames:
1091         - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1092         - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1093         - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1094         - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1095         - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1096         - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1097         - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1098         - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1099         - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1100         - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1101         - s84-t213-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1102         - s84-t213-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1103 - SUT [Server-Type-F1]:
1104     - testbedname: testbed214.
1105     - hostname: s85-t214-sut1.
1106     - IPMI IP: 10.30.50.85
1107     - Host IP: 10.30.51.85
1108     - portnames:
1109         - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1110         - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1111         - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1112         - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1113         - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1114         - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1115         - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1116         - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1117         - s85-t214-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1118         - s85-t214-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1119 - TG [Server-Type-F2]:
1120     - testbedname: testbed214.
1121     - hostname: s86-t214-tg1.
1122     - IPMI IP: 10.30.50.86
1123     - Host IP: 10.30.51.86
1124     - portnames:
1125         - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1126         - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1127         - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1128         - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1129         - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1130         - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1131         - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1132         - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1133         - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1134         - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1135         - s86-t214-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1136         - s86-t214-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1137 - SUT [Server-Type-F1]:
1138     - testbedname: testbed215.
1139     - hostname: s87-t215-sut1.
1140     - IPMI IP: 10.30.50.87
1141     - Host IP: 10.30.51.87
1142     - portnames:
1143         - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1144         - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1145         - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1146         - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1147         - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1148         - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1149         - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1150         - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1151         - s87-t215-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1152         - s87-t215-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1153 - TG [Server-Type-F2]:
1154     - testbedname: testbed215.
1155     - hostname: s88-t215-tg1.
1156     - IPMI IP: 10.30.50.88
1157     - Host IP: 10.30.51.88
1158     - portnames:
1159         - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1160         - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1161         - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1162         - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1163         - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1164         - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1165         - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1166         - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1167         - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1168         - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1169         - s88-t215-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1170         - s88-t215-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1171 ```
1172
1173 ### 3-Node-Rangeley (3n-rng)
1174
1175 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1176
1177 ```
1178 - ServerB22 [Server-Type-B5]:
1179     - testbedname: testbed35.
1180     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1181     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1182     - Host IP: 10.30.51.9
1183     - portnames:
1184         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1185         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1186     - 1GB ports (tbd)
1187 - ServerB23 [Server-Type-B5]:
1188     - testbedname: testbed35.
1189     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1190     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1191     - Host IP: 10.30.51.10
1192     - portnames:
1193         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1194         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1195     - 1GB ports (tbd)
1196 - ServerB24 [Server-Type-B5]:
1197     - testbedname: testbed35.
1198     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1199     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1200     - Host IP: 10.30.51.11
1201     - portnames:
1202         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1203         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1204     - 1GB ports (tbd)
1205 ```
1206
1207 ### 3-Node-Taishan (3n-tsh)
1208
1209 {{< figure src="/cdocs/testbed-3n-tsh.svg" >}}
1210
1211 ```
1212 - SUT [Server-Type-E21]:
1213     - testbedname: testbed33.
1214     - hostname: s17-t33-sut1.
1215     - IPMI IP: 10.30.50.36
1216     - Host IP: 10.30.51.36
1217     - portnames:
1218         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1219         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1220         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1221         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1222 - SUT [Server-Type-E21]:
1223     - testbedname: testbed33.
1224     - hostname: s18-t33-sut2.
1225     - IPMI IP: 10.30.50.37
1226     - Host IP: 10.30.51.37
1227     - portnames:
1228         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1229         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1230         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1231         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1232 - TG [Server-Type-E31]:
1233     - testbedname: testbed33 and testbed211.
1234     - hostname: s19-t33t211-tg1.
1235     - IPMI IP: 10.30.50.46
1236     - Host IP: 10.30.51.49
1237     - portnames:
1238         - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1239         - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1240         - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1241         - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1242         - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1243         - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1244         - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1245         - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1246         - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1247         - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1248         - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1249         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1250 ```
1251
1252 ### 3-Node-Altra (3n-alt)
1253
1254 {{< figure src="/cdocs/testbed-3n-alt.svg" >}}
1255
1256 ```
1257 - SUT [Server-Type-E23]:
1258     - testbedname: testbed34.
1259     - hostname: s62-t34-sut1.
1260     - IPMI IP: 10.30.50.72
1261     - Host IP: 10.30.51.72
1262     - portnames:
1263         - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1264         - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1265         - s62-t34-sut1-c8/p1 - 100GE-port1 ConnectX6-2p100GE.
1266         - s62-t34-sut1-c8/p2 - 100GE-port2 ConnectX6-2p100GE.
1267 - SUT [Server-Type-E23]:
1268     - testbedname: testbed34.
1269     - hostname: s63-t34-sut2.
1270     - IPMI IP: 10.30.50.73
1271     - Host IP: 10.30.51.73
1272     - portnames:
1273         - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1274         - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1275         - s63-t34-sut2-c8/p1 - 100GE-port1 ConnectX6-2p100GE.
1276         - s63-t34-sut2-c8/p2 - 100GE-port2 ConnectX6-2p100GE.
1277 - TG [Server-Type-E32]:
1278     - testbedname: testbed34.
1279     - hostname: s64-t34-tg1.
1280     - IPMI IP: 10.30.50.74
1281     - Host IP: 10.30.51.74
1282     - portnames:
1283         - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1284         - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1285         - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1286         - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1287         - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1288         - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1289         - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1290         - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1291         - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1292         - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1293 ```
1294
1295 ### 3-Node-Icelake (3n-icx)
1296
1297 {{< figure src="/cdocs/testbed-3n-icx.svg" >}}
1298
1299 ```
1300 - SUT1 [Server-Type-F3]:
1301     - testbedname: testbed37.
1302     - hostname: s65-t37-sut1.
1303     - IPMI IP: 10.30.50.75
1304     - Host IP: 10.30.51.75
1305     - portnames:
1306         - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1307         - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1308         - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1309         - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1310         - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1311         - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1312         - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1313         - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1314         - s65-t37-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE.
1315         - s65-t37-sut1-c6/p2 - 100GE-port2 ConnectX6-2p100GE.
1316 - SUT2 [Server-Type-F3]:
1317     - testbedname: testbed37.
1318     - hostname: s66-t37-sut2.
1319     - IPMI IP: 10.30.50.76
1320     - Host IP: 10.30.51.76
1321     - portnames:
1322         - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1323         - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1324         - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1325         - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1326         - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1327         - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1328         - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1329         - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1330         - s65-t37-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE.
1331         - s65-t37-sut1-c6/p2 - 100GE-port2 ConnectX6-2p100GE.
1332 - TG [Server-Type-F3]:
1333     - testbedname: testbed37.
1334     - hostname: s67-t37-tg1.
1335     - IPMI IP: 10.30.50.77
1336     - Host IP: 10.30.51.77
1337     - portnames:
1338         - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1339         - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1340         - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1341         - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1342         - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1343         - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1344         - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1345         - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1346         - s67-t37-tg1-c6/p1 - 100GE-port1 ConnectX6-2p100GE.
1347         - s67-t37-tg1-c6/p2 - 100GE-port2 ConnectX6-2p100GE.
1348 - SUT1 [Server-Type-F3]:
1349     - testbedname: testbed38.
1350     - hostname: s78-t38-sut1.
1351     - IPMI IP: 10.30.50.78
1352     - Host IP: 10.30.51.78
1353     - portnames:
1354         - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1355         - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1356         - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1357         - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1358         - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1359         - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1360         - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1361         - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1362         - s78-t38-sut1-c6/p1 - 100GE-port1 ConnectX6-2p100GE.
1363         - s78-t38-sut1-c6/p2 - 100GE-port2 ConnectX6-2p100GE.
1364 - SUT2 [Server-Type-F3]:
1365     - testbedname: testbed38.
1366     - hostname: s79-t38-sut2.
1367     - IPMI IP: 10.30.50.79
1368     - Host IP: 10.30.51.79
1369     - portnames:
1370         - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1371         - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1372         - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1373         - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1374         - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1375         - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1376         - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1377         - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1378         - s79-t38-sut2-c6/p1 - 100GE-port1 ConnectX6-2p100GE.
1379         - s79-t38-sut2-c6/p2 - 100GE-port2 ConnectX6-2p100GE.
1380 - TG [Server-Type-F3]:
1381     - testbedname: testbed38.
1382     - hostname: s80-t38-tg1.
1383     - IPMI IP: 10.30.50.80
1384     - Host IP: 10.30.51.80
1385     - portnames:
1386         - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1387         - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1388         - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1389         - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1390         - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1391         - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1392         - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1393         - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1394         - s80-t38-tg1-c6/p1 - 100GE-port1 ConnectX6-2p100GE.
1395         - s80-t38-tg1-c6/p2 - 100GE-port2 ConnectX6-2p100GE.
1396 ```
1397
1398 ### 3-Node-SnowRidge (3n-snr)
1399
1400 {{< figure src="/cdocs/testbed-3n-snr.svg" >}}
1401
1402 ```
1403 - ServerG1 [Server-Type-G1]:
1404     - testbedname: testbed39.
1405     - hostname: s93-t39-sut1.
1406     - IPMI IP: 10.30.50.93
1407     - Host IP: 10.30.51.93
1408     - portnames:
1409         - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1410         - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1411         - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
1412         - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
1413 - ServerG1 [Server-Type-G1]:
1414     - testbedname: testbed39.
1415     - hostname: s94-t39-sut2.
1416     - IPMI IP: 10.30.50.94
1417     - Host IP: 10.30.51.94
1418     - portnames:
1419         - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1420         - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1421         - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1422         - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1423 - ServerF4 [Server-Type-F5]:
1424     - testbedname: testbed39.
1425     - hostname: s89-t39t310-tg1.
1426     - IPMI IP: 10.30.50.89
1427     - Host IP: 10.30.51.89
1428     - portnames:
1429         - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1430         - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1431         - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1432         - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1433 ```
1434
1435 ### 2-Node-SapphireRapids (2n-spr)
1436
1437 {{< figure src="/cdocs/testbed-2n-spr.svg" >}}
1438
1439 ```
1440 - SUT [Server-Type-H1]:
1441     - testbedname: testbed21.
1442     - hostname: s52-t21-sut1.
1443     - IPMI IP: 10.30.50.52
1444     - Host IP: 10.30.51.52
1445     - portnames:
1446         - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
1447         - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
1448         - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
1449         - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
1450         - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1451         - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1452         - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
1453         - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
1454         - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1455         - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1456 - TG [Server-Type-H2]:
1457     - testbedname: testbed21.
1458     - hostname: s53-t21-tg1.
1459     - IPMI IP: 10.30.50.53
1460     - Host IP: 10.30.51.53
1461     - portnames:
1462         - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
1463         - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
1464         - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
1465         - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
1466         - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1467         - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1468         - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
1469         - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
1470         - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1471         - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1472 - SUT [Server-Type-H3]:
1473     - testbedname: testbed22.
1474     - hostname: s54-t22-sut1.
1475     - IPMI IP: 10.30.50.54
1476     - Host IP: 10.30.51.54
1477     - portnames:
1478         - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1479         - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1480         - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1481         - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1482         - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1483         - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1484         - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1485         - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1486         - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1487         - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1488         - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1489         - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1490 - TG [Server-Type-H4]:
1491     - testbedname: testbed22.
1492     - hostname: s55-t22-tg1.
1493     - IPMI IP: 10.30.50.55
1494     - Host IP: 10.30.51.55
1495     - portnames:
1496         - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1497         - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1498         - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1499         - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1500         - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1501         - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1502 - SUT [Server-Type-H5]:
1503     - testbedname: testbed23.
1504     - hostname: s56-t23-sut1.
1505     - IPMI IP: 10.30.50.56
1506     - Host IP: 10.30.51.56
1507     - portnames:
1508         - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1509         - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1510         - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1511         - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1512         - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1513         - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1514         - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1515         - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1516 - TG [Server-Type-H6]:
1517     - testbedname: testbed23.
1518     - hostname: s57-t23-tg1.
1519     - IPMI IP: 10.30.50.57
1520     - Host IP: 10.30.51.57
1521     - portnames:
1522         - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1523         - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1524         - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1525         - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1526         - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1527         - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1528         - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1529         - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1530         - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1531         - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1532         - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1533         - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1534 - SUT [Server-Type-H5]:
1535     - testbedname: testbed24.
1536     - hostname: s58-t24-sut1.
1537     - IPMI IP: 10.30.50.58
1538     - Host IP: 10.30.51.58
1539     - portnames:
1540         - s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1541         - s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1542         - s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1543         - s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1544         - s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1545         - s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1546         - s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1547         - s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1548 - TG [Server-Type-H6]:
1549     - testbedname: testbed24.
1550     - hostname: s59-t24-tg1.
1551     - IPMI IP: 10.30.50.59
1552     - Host IP: 10.30.51.59
1553     - portnames:
1554         - s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1555         - s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1556         - s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1557         - s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1558         - s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1559         - s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1560         - s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1561         - s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1562         - s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1563         - s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1564         - s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1565         - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1566 ```
1567
1568 ## Testbed Wiring
1569
1570 ### 1-Node-Skylake (1n-skx)
1571
1572 ```
1573 - testbed11:
1574     - ring1 10GE-ports x710-4p10GE:
1575         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1576     - ring2 10GE-ports x710-4p10GE:
1577         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1578     - ring3 10GE-ports x710-4p10GE:
1579         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1580     - ring4 10GE-ports x710-4p10GE:
1581         - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1582     - ring5 100GE-ports e810-2p100GE:
1583         - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1584     - ring6 100GE-ports e810-2p100GE:
1585         - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1586 - testbed12:
1587     - ring1 10GE-ports x710-4p10GE:
1588         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1589     - ring2 10GE-ports x710-4p10GE:
1590         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1591     - ring3 10GE-ports x710-4p10GE:
1592         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1593     - ring4 10GE-ports x710-4p10GE:
1594         - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1595     - ring5 100GE-ports e810-2p100GE:
1596         - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1597     - ring6 100GE-ports e810-2p100GE:
1598         - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1599 ```
1600
1601 ### 1-Node-ThunderX2 (1n-tx2)
1602
1603 ```
1604 - testbed13:
1605     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1606         - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1607     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1608         - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1609     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1610         - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1611     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1612         - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1613
1614 - testbed14:
1615     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1616         - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1617     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1618         - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1619     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1620         - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1621     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1622         - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1623 ```
1624
1625 ### 2-Node-IxiaPS1L47 (2n-ps1)
1626
1627 ```
1628 - testbed25:
1629     - link1 10GE-port x710-4p10GE on SUT:
1630         - t25-tg1-p1 to t25-sut1-c2/p1.
1631     - link2 10GE-port x710-4p10GE on SUT:
1632         - t25-tg1-p2 to t25-sut1-c2/p2.
1633     - link3 10GE-port x710-4p10GE on SUT:
1634         - t25-tg1-p3 to t25-sut1-c2/p3.
1635     - link4 10GE-port x710-4p10GE on SUT:
1636         - t25-tg1-p4 to t25-sut1-c2/p4.
1637 ```
1638
1639 ### 2-Node-Cascadelake (2n-clx)
1640
1641 ```
1642 - testbed27:
1643     - ring1 10GE-ports x710-4p10GE on SUT:
1644         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1645         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1646     - ring2 10GE-ports x710-4p10GE on SUT:
1647         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1648         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1649     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1650         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1651         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1652     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1653         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1654         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1655     - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1656         - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1657         - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1658     - ring6 100GE-ports e810-2p100GE on TG:
1659         - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
1660         - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
1661 - testbed28:
1662     - ring1 10GE-ports x710-4p10GE on SUT:
1663         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1664         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1665     - ring2 10GE-ports x710-4p10GE on SUT:
1666         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1667         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1668     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1669         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1670         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1671     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1672         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1673         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1674     - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1675         - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1676         - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1677     - ring6 100GE-ports e810-2p100GE on TG:
1678         - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
1679         - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
1680 - testbed29:
1681     - ring1 10GE-ports x710-4p10GE on SUT:
1682         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1683         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1684     - ring2 10GE-ports x710-4p10GE on SUT:
1685         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1686         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1687     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1688         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1689         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1690     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1691         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1692         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1693     - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1694         - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1695         - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1696 ```
1697
1698 ### 2-Node-Zen2 (2n-zn2)
1699
1700 ```
1701 - testbed210:
1702     - ring1 10GE-ports x710-4p10GE on SUT:
1703         - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1704         - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1705     - ring2 10GE-ports x710-4p10GE on SUT:
1706         - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1707         - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1708     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1709         - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1710         - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1711     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1712         - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1713         - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1714 ```
1715
1716 ### 2-Node-ThunderX2 (2n-tx2)
1717
1718 ```
1719 - testbed211:
1720     - ring1 10GE-ports x520-2p10GE on SUTs:
1721         - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
1722         - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
1723 ```
1724
1725 ### 2-Node-Icelake (2n-icx)
1726
1727 ```
1728 - testbed212:
1729     - ring1 25GE-ports xxv710-DA2-2p25GE:
1730         - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
1731         - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
1732     - ring2 25GE-ports e810-XXVDA4-2p25GE:
1733         - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
1734         - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
1735         - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
1736         - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
1737     - ring3 100GE-ports e810-2CQDA2-2p100GE:
1738         - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
1739         - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
1740     - ring4 100GE-ports e810-2CQDA2-2p100GE:
1741         - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
1742         - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
1743     - ring5 200GE-ports ConnectX7-2p200GE:
1744         - s72-t212-tg1-c8/p1 to s71-t212-sut1-c8/p1.
1745         - s71-t212-sut1-c8/p2 to s72-t212-tg1-c8/p2.
1746 - testbed213:
1747     - ring1 25GE-ports xxv710-DA2-2p25GE:
1748         - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
1749         - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
1750     - ring2 25GE-ports e810-XXVDA4-2p25GE:
1751         - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
1752         - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
1753         - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
1754         - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
1755     - ring3 100GE-ports e810-2CQDA2-2p100GE:
1756         - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
1757         - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
1758     - ring4 100GE-ports e810-2CQDA2-2p100GE:
1759         - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
1760         - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
1761     - ring5 200GE-ports ConnectX7-2p200GE:
1762         - s84-t213-tg1-c8/p1 to s83-t213-sut1-c8/p1.
1763         - s83-t213-sut1-c8/p2 to s84-t213-tg1-c8/p2.
1764 - testbed214:
1765     - ring1 25GE-ports xxv710-DA2-2p25GE:
1766         - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
1767         - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
1768     - ring2 25GE-ports e810-XXVDA4-2p25GE:
1769         - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
1770         - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
1771         - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
1772         - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
1773     - ring3 100GE-ports e810-2CQDA2-2p100GE:
1774         - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
1775         - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
1776     - ring4 100GE-ports e810-2CQDA2-2p100GE:
1777         - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
1778         - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
1779     - ring5 200GE-ports ConnectX7-2p200GE:
1780         - s86-t214-tg1-c8/p1 to s85-t214-sut1-c8/p1.
1781         - s85-t214-sut1-c8/p2 to s86-t214-tg1-c8/p2.
1782 - testbed215:
1783     - ring1 25GE-ports xxv710-DA2-2p25GE:
1784         - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
1785         - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
1786     - ring2 25GE-ports e810-XXVDA4-2p25GE:
1787         - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
1788         - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
1789         - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
1790         - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
1791     - ring3 100GE-ports e810-2CQDA2-2p100GE:
1792         - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
1793         - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
1794     - ring4 100GE-ports e810-2CQDA2-2p100GE:
1795         - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
1796         - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
1797     - ring5 200GE-ports ConnectX7-2p200GE:
1798         - s88-t215-tg1-c8/p1 to s87-t215-sut1-c8/p1.
1799         - s87-t215-sut1-c8/p2 to s88-t215-tg1-c8/p2.
1800 ```
1801
1802 ### 3-Node-Rangeley (3n-rng)
1803
1804 ```
1805 To be completed.
1806 ```
1807
1808 ### 3-Node-Taishan (3n-tsh)
1809
1810 ```
1811 - testbed33:
1812     - ring1 10GE-ports x520-2p10GE on SUTs:
1813         - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1814         - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1815         - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
1816     - ring2 25GE-ports cx4-2p25GE on SUTs:
1817         - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1818         - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1819         - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
1820 ```
1821
1822 ### 3-Node-Altra (3n-alt)
1823
1824 ```
1825 - testbed34:
1826     - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
1827         - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
1828         - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
1829         - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
1830     - ring2 100GE-ports ConnectX6-2p100GE Mellanox on SUTs:
1831         - s64-t34-tg1-c8/p1 - s62-t34-sut1-c8/p2.
1832         - s62-t34-sut1-c8/p1 - s63-t34-sut2-c8/p2.
1833         - s63-t34-sut2-c8/p1 - s64-t34-tg1-c8/p2.
1834 ```
1835
1836 ### 3-Node-Icelake (3n-icx)
1837
1838 ```
1839 - testbed37:
1840     - ring1 25GE-ports xxv710-DA2-2p25GE:
1841         - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
1842         - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
1843         - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
1844     - ring2 25GE-ports e810-XXVDA4-4p25GE:
1845         - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
1846         - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
1847         - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
1848         - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
1849         - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
1850         - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
1851     - ring3 100GE-ports e810-2CQDA2-2p100GE:
1852         - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
1853         - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
1854         - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
1855     - ring4 200GE-ports ConnectX6-2p200GE:
1856         - s67-t37-tg1-c6/p1 - s65-t37-sut1-c6/p2.
1857         - s65-t37-sut1-c6/p1 - s66-t37-sut2-c6/p2.
1858         - s66-t37-sut2-c6/p1 - s67-t37-tg1-c9-c6/p2.
1859 - testbed38:
1860     - ring1 25GE-ports xxv710-DA2-2p25GE:
1861         - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
1862         - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
1863         - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
1864     - ring2 25GE-ports e810-XXVDA4-4p25GE:
1865         - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
1866         - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
1867         - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
1868         - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
1869         - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
1870         - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
1871     - ring3 100GE-ports e810-2CQDA2-2p100GE:
1872         - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
1873         - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
1874         - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
1875     - ring4 200GE-ports ConnectX6-2p200GE:
1876         - s80-t38-tg1-c6/p1 to s78-t38-sut1-c6/p1.
1877         - s78-t38-sut1-c6/p2 to s79-t38-sut2-c6/p2.
1878         - s79-t38-sut2-c6/p1 to s80-t38-tg1-c6/p2.
1879 ```
1880
1881 ### 3-Node-SnowRidge (3n-snr)
1882
1883 ```
1884 - testbed39:
1885     - ring1 25GE-ports e810-XXVDA4-4p25GE:
1886         - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
1887         - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
1888         - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
1889         - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
1890         - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
1891         - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
1892 ```
1893
1894 ### 2-Node-SapphireRapids (2n-spr)
1895
1896 ```
1897 - testbed21:
1898     - ring1 200GE-ports ConnectX7-2p200GE:
1899         - s53-t21-tg1-c2/p1 to s52-t21-sut1-c2/p1
1900         - s53-t21-tg1-c7/p1 to s52-t21-sut1-c7/p1
1901         - s52-t21-sut1-c4/p2 to s52-t21-sut1-c9/p2
1902     - ring2 200GE-ports ConnectX7-2p200GE:
1903         - s53-t21-tg1-c2/p2 to s52-t21-sut1-c2/p2
1904         - s53-t21-tg1-c7/p2 to s52-t21-sut1-c7/p2
1905         - s52-t21-sut1-c10/p1 to s52-t21-sut1-c11/p1
1906     - ring3 200GE-ports ConnectX7-2p200GE:
1907         - s53-t21-tg1-c4/p1 to s52-t21-sut1-c4/p1
1908         - s53-t21-tg1-c9/p1 to s52-t21-sut1-c9/p1
1909         - s52-t21-sut1-c10/p2 to s52-t21-sut1-c11/p2
1910 - testbed22:
1911     - ring1 100GE-ports e810-2CQDA2-2p100GE:
1912         - s55-t22-tg1-c4/p1  to s54-t22-sut1-c9/p2
1913         - s55-t22-tg1-c4/p2  to s54-t22-sut1-c4/p2
1914         - s54-t22-sut1-c9/p1 to s54-t22-sut1-c4/p1
1915     - ring2 25GE-ports e810-XXVDA4-4p25GE:
1916         - s55-t22-tg1-c2/p1  to s54-t22-sut1-c2/p1
1917         - s55-t22-tg1-c2/p2  to s54-t22-sut1-c7/p1
1918         - s54-t22-sut1-c2/p2 to s54-t22-sut1-c7/p2
1919 - testbed23:
1920     - ring1 200GE-ports ConnectX7-2p200GE:
1921         - s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1.
1922         - s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2.
1923     - ring2 100GE-ports e810-2CQDA2-2p100GE:
1924         - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1.
1925         - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2.
1926     - ring3 25GE-ports e810-XXVDA4-2p25GE:
1927         - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1.
1928         - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2.
1929         - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3.
1930         - s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4.
1931     - ring4 200GE-ports ConnectX7-2p200GE:
1932         - s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2.
1933     - ring5 100GE-ports e810-2CQDA2-2p100GE:
1934         - s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2.
1935 - testbed24:
1936     - ring1 200GE-ports ConnectX7-2p200GE:
1937         - s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1.
1938         - s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2.
1939     - ring2 100GE-ports e810-2CQDA2-2p100GE:
1940         - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1.
1941         - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2.
1942     - ring3 25GE-ports e810-XXVDA4-2p25GE:
1943         - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1.
1944         - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2.
1945         - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3.
1946         - s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4.
1947     - ring4 200GE-ports ConnectX7-2p200GE:
1948         - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2.
1949     - ring5 100GE-ports e810-2CQDA2-2p100GE: