feat(infra): Add new SPR servers
[csit.git] / docs / content / infrastructure / fdio_dc_testbed_specifications.md
1 ---
2 bookToc: true
3 title: "FD.io DC Testbed Specifications"
4 weight: 2
5 ---
6
7 # FD.io DC Testbed Specifications
8
9 ## Purpose
10
11 This note includes specification of the physical testbed infrastructure
12 hosted by LFN FD.io CSIT project.
13
14 ## Server Management
15
16 ### Addressing
17
18 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
19 Management port, which are connected to two different VLANs.
20
21 #### LOM (IPMI) VLAN
22    - Subnet: 10.30.50.0/24
23    - Gateway: 10.30.50.1
24    - Broadcast: 10.30.50.255
25    - DNS1: 199.204.44.24
26    - DNS2: 199.204.47.54
27
28 #### Management VLAN
29    - Subnet: 10.30.51.0/24
30    - Gateway: 10.30.51.1
31    - Broadcast: 10.30.51.255
32    - DNS1: 199.204.44.24
33    - DNS2: 199.204.47.54
34
35 To access these hosts, VPN connection is required.
36
37 ## Testbeds Overview
38
39 ### Summary List
40
41 ```
42  #. Type                 Purpose  SUT   TG    #TB  #SUT #TG  #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr
43  1. 1-Node-Skylake         nomad  skx   na    5    5    0    5    0    0    0    0    0    0    0    0    0    0
44  2. 1-Node-Cascadelake     nomad  clx   na    1    1    0    0    0    0    0    0    0    1    0    0    0    0
45  3. 1-Node-AmpereAltra     nomad  alt   na    2    2    0    0    0    0    0    0    2    0    0    0    0    0
46  4. 2-Node-IxiaPS1L47      tcp    skx   ps1   1    1    1    1    1    0    0    0    0    0    0    0    0    0
47  5. 2-Node-Cascadelake     perf   clx   clx   3    3    3    0    0    0    0    0    0    6    0    0    0    0
48  6. 2-Node-ThunderX2       perf   tx2   skx   1    1    .5   .5   0    0    1    0    0    0    0    0    0    0
49  7. 2-Node-Icelake         perf   icx   icx   4    4    4    0    0    0    0    0    0    0    0    8    0    0
50  8. 3-Node-Rangeley        perf   rng   skx   1    3    1    0    0    2    0    0    0    0    0    0    0    0
51  9. 3-Node-Taishan         perf   tsh   skx   1    2    .5   .5   0    0    0    2    0    0    0    0    0    0
52 10. 3-Node-Altra           perf   alt   icx   1    2    1    0    0    0    0    0    2    0    0    1    0    0
53 11. 2-Node-Zen2            perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    2    0    0    0
54 12. 3-Node-Icelake         perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    6    0    0
55 13. 3-Node-SnowRidge       perf   snr   icx   1    2    .5   0    0    0    0    0    0    0    0    .5   2    0
56 14. 2-Node-SapphireRapids  perf   spr   spr   4    4    4    0    0    0    0    0    0    0    0    0    0    8
57 15. 1-Node-SapphireRapids  nomad  spr   na    4    4    0    0    0    0    0    0    0    0    0    0    0    4
58                                      Totals: 32   39  18.5   7    1    2    1    2    4    7    2   15.5  2   12
59 ```
60
61 ### 1-Node-Skylake Xeon Intel (1n-skx)
62
63 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
64 ports connected back-to-back ([Server Types](#server-types)).
65 Used for FD.io VPP_Device functional driver tests.
66
67 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
68
69 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
70 ports connected back-to-back ([Server Types](#server-types)).
71 Used for FD.io VPP_Device functional driver tests.
72
73 ### 1-Node-Skylake Xeon Intel (1n-spr)
74
75 Each 1-Node-SapphireRapids testbed includes one SUT (Server-Type-H7) with NIC
76 ports connected back-to-back ([Server Types](#server-types)).
77 Used for FD.io VPP_Device functional driver tests.
78
79 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
80
81 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
82 NIC ports connected back-to-back ([Server Types](#server-types)).
83
84 Used for FD.io VPP_Device functional driver tests.
85
86 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
87
88 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
89 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
90 circular topology ([Server Types](#server-types)).
91 Used for FD.io TCP/IP and HTTP performance tests.
92
93 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
94
95 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
96 one TG (Server-Type-C3) connected in a 2-node circular topology
97 ([Server Types](#server-types)).
98 Used for FD.io performance tests.
99
100 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
101
102 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
103 one TG (Server-Type-D2) connected in a 2-node circular topology
104 ([Server Types](#server-types)).
105 Used for FD.io performance tests.
106
107 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
108
109 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
110 one TG (Server-Type-E31) connected in a 2-node circular topology
111 ([Server Types](#server-types)).
112 Used for FD.io performance tests.
113
114 ### 2-Node-Icelake Xeon Intel (2n-icx)
115
116 Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
117 one TG (Server-Type-F2) connected in a 2-node circular topology
118 ([Server Types](#server-types)).
119 Used for FD.io performance tests.
120
121 ### 3-Node-Rangeley Atom Testbeds
122
123 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
124 TG (Server-Type-2) connected in a 3-node circular topology
125 ([Server Types](#server-types)).
126 Used for FD.io performance tests.
127
128 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
129
130 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
131 TG (Server-Type-E31) connected in a 3-node circular topology
132 ([Server Types](#server-types)).
133 Used for FD.io performance tests.
134
135 ### 3-Node-Altra Arm Ampere (3n-alt)
136
137 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
138 TG (Server-Type-E32) connected in a 3-node circular topology
139 ([Server Types](#server-types)).
140 Used for FD.io performance tests.
141
142 ### 3-Node-Icelake Xeon Intel (3n-icx)
143
144 Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F3) and one
145 TG (Server-Type-F3) connected in a 3-node circular topology
146 ([Server Types](#server-types)).
147 Used for FD.io performance tests.
148
149 ### 3-Node-SnowRidge Atom Intel (3n-snr)
150
151 Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
152 TG (Server-Type-F5) connected in a 3-node circular topology
153 ([Server Types](#server-types)).
154 Used for FD.io performance tests.
155
156 ### 2-Node-SapphireRapids Xeon Intel (2n-spr)
157
158 Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and
159 one TG (Server-Type-H6) connected in a 2-node or 3-node circular topology
160 ([Server Types](#server-types)).
161 Used for FD.io performance tests.
162
163
164 ## Tesdtbed Naming Convention
165
166 Following naming convention is used within this page to specify physical
167 connectivity and wiring across defined CSIT testbeds:
168
169 - **testbedname**: testbedN.
170 - **hostname**:
171     - traffic-generator: tN-tgW.
172     - system-under-testX: tN-sutX.
173 - **portnames**:
174     - tN-tgW-cY/pZ.
175     - tN-sutX-cY/pZ.
176 - **where**:
177     - N - testbed number.
178     - tgW - server acts as traffic-generator with W index.
179     - sutX - server acts as system-under-test with X index.
180     - Y - PCIe slot number denoting a NIC card number within the host.
181     - Z - port number on the NIC card.
182
183 ## Server Types
184
185 FD.io CSIT lab contains following server types:
186
187 1. **Server-Type-B2**: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
188     - Quantity: 2
189     - Physical connectivity:
190         - IPMI and host management ports.
191     - Main HW configuration:
192         - Chassis: SuperMicro SYS-7049GP-TRT.
193         - Motherboard: SuperMicro X11DPG-QT.
194         - Processors: 2* Intel Platinum 8180 2.5 GHz.
195         - RAM Memory: 16* 16GB DDR4-2666MHz.
196         - Disks: 2* 1.6TB 6G SATA SSD.
197     - NICs configuration:
198         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
199             - PCIe Slot2 18:00.xx: empty.
200             - PCIe Slot4 3b:00.xx: empty.
201             - PCIe Slot9 5e:00.xx: empty.
202         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
203             - PCIe Slot6 86:00.xx: empty.
204             - PCIe Slot8 af:00.xx: empty.
205             - PCIe Slot10 d8:00.xx: empty.
206
207 2. **Server-Type-B6**: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
208     - Quantity: 2.
209     - Physical connectivity:
210         - IPMI and host management ports.
211         - NIC ports connected into 1-node topologies.
212     - Main HW configuration:
213         - Chassis: SuperMicro SYS-7049GP-TRT.
214         - Motherboard: SuperMicro X11DPG-QT.
215         - Processors: 2* Intel Platinum 8180 2.5 GHz.
216         - RAM Memory: 16* 16GB DDR4-2666MHz.
217         - Disks: 2* 1.6TB 6G SATA SSD.
218     - NICs configuration:
219         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
220             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
221             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
222             - PCIe Slot9 5e:00.xx: empty.
223         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
224             - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
225             - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
226             - PCIe Slot10 d8:00.xx: empty.
227
228 3. **Server-Type-B7**: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
229     - Quantity: 1.
230     - Physical connectivity:
231         - Host management interface: 10/100/1000-BaseT.
232         - 8-port 10GE SFP+ integrated NIC.
233     - Main HW configuration:
234         - Chassis: PS10GE4NG.
235         - Motherboard: SuperMicro X11DPG-QT.
236         - Processors: Quad-Core, Intel Processor.
237         - HW accelerators: FPGA offload.
238         - RAM Memory: 64GB.
239         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
240         - Physical Interfaces: 4 * 10GE SFP+.
241         - Operating System: Native IxOS.
242     - Interface configuration:
243         - Port-1: 10GE SFP+.
244         - Port-2: 10GE SFP+.
245         - Port-3: 10GE SFP+.
246         - Port-4: 10GE SFP+.
247
248 4. **Server-Type-B8**: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
249     - Quantity: 1.
250     - Physical connectivity:
251         - IPMI and host management ports.
252         - NIC ports.
253     - Main HW configuration:
254         - Chassis: SuperMicro SYS-7049GP-TRT.
255         - Motherboard: SuperMicro X11DPG-QT.
256         - Processors: 2* Intel Platinum 8180 2.5 GHz.
257         - RAM Memory: 16* 16GB DDR4-2666MHz.
258         - Disks: 2* 1.6TB 6G SATA SSD.
259     - NICs configuration:
260         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
261             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
262             - PCIe Slot4 3b:00.xx: empty.
263             - PCIe Slot9 5e:00.xx: empty.
264         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
265             - PCIe Slot6 86:00.xx: empty.
266             - PCIe Slot8 af:00.xx: empty.
267             - PCIe Slot10 d8:00.xx: empty.
268 5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
269     - Quantity: 1.
270     - Physical connectivity:
271         - IPMI and host management ports.
272         - NIC ports connected into 1-node testbed topologies.
273     - Main HW configuration:
274         - Chassis: SuperMicro SYS-7049GP-TRT.
275         - Motherboard: SuperMicro X11DPG-QT.
276         - Processors: 2* Intel Platinum 8280 2.7 GHz.
277         - RAM Memory: 12* 16GB DDR4-2933.
278         - Disks: 2* 1.92TB SATA SSD.
279     - NICs configuration:
280         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
281             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
282             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
283             - PCIe Slot9 5e:00.xx: empty.
284         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
285             - PCIe Slot6 86:00.xx: empty.
286             - PCIe Slot8 af:00.xx: empty.
287             - PCIe Slot10 d8:00.xx: empty.
288
289 6. **Server-Type-C2**: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
290     - Quantity: 3
291     - Physical connectivity:
292         - IPMI and host management ports.
293         - NIC ports connected into 2-node testbed topologies.
294     - Main HW configuration:
295         - Chassis: SuperMicro SYS-7049GP-TRT.
296         - Motherboard: SuperMicro X11DPG-QT.
297         - Processors: 2* Intel Gold 6252N 2.3 GHz.
298         - RAM Memory: 12* 16GB DDR4-2933.
299         - Disks: 2* 1.92TB SATA SSD.
300     - NICs configuration:
301         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
302             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
303             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
304             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
305         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
306             - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
307             - PCIe Slot8 af:00.xx: empty.
308             - PCIe Slot10 d8:00.xx: empty.
309
310 7. **Server-Type-C3**: Purpose - Cascadelake Xeon TG for FD.io performance testing.
311     - Quantity: 3.
312     - Physical connectivity:
313         - IPMI and host management ports.
314         - NIC ports connected into 2-node testbed topologies.
315     - Main HW configuration:
316         - Chassis: SuperMicro SYS-7049GP-TRT.
317         - Motherboard: SuperMicro X11DPG-QT.
318         - Processors: 2* Intel Platinum 8280 2.7 GHz.
319         - RAM Memory: 12* 16GB DDR4-2933.
320         - Disks: 2* 1.92TB SATA SSD.
321     - NICs configuration:
322         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
323             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
324             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
325             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
326         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
327             - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
328             - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
329             - PCIe Slot10 d8:00.xx: empty.
330
331 8. **Server-Type-C4**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
332     - Quantity: 3.
333     - Physical connectivity:
334         - IPMI and host management ports.
335         - no NIC ports, standalone setup.
336     - Main HW configuration:
337         - Chassis: SuperMicro 1029P-WTRT.
338         - Motherboard: SuperMicro X11DDW-NT.
339         - Processors: 2* Intel Platinum 8280 2.7 GHz.
340         - RAM Memory: 12* 16GB DDR4-2933.
341         - Disks: 4* 1.92TB SATA SSD.
342     - NICs configuration:
343         - Numa0:
344             - no cards.
345         - Numa1:
346             - no cards.
347
348 9. **Server-Type-D1**: Purpose - Zen2 EPYC SUT for FD.io performance testing.
349     - Quantity: 1.
350     - Physical connectivity:
351         - IPMI and host management ports.
352         - NIC ports connected into 2-node testbed topologies.
353     - Main HW configuration:
354         - Chassis: SuperMicro AS-1114S-WTRT
355         - Processors: 1* AMD EPYC 7532 2.4 GHz.
356         - RAM Memory: 8* 32GB DDR4-2933.
357         - Disks: 1* 1TB SATA SSD.
358     - NICs configuration:
359         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
360             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
361             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
362             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
363
364 10. **Server-Type-D2**: Purpose - Zen2 EPYC TG for FD.io performance testing.
365     - Quantity: 1.
366     - Physical connectivity:
367         - IPMI and host management ports.
368         - NIC ports connected into 2-node testbed topologies.
369     - Main HW configuration:
370         - Chassis: SuperMicro AS-1114S-WTRT
371         - Processors: 1* AMD EPYC 7532 2.4 GHz.
372         - RAM Memory: 8* 32GB DDR4-2933.
373         - Disks: 1* 1TB SATA SSD.
374     - NICs configuration:
375         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
376             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
377             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
378             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
379
380 11. **Server-Type-E11**: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
381     - Quantity: 2.
382     - Physical connectivity:
383         - IPMI and host management ports.
384         - NIC ports connected into 1-node topologies.
385     - Main HW configuration:
386         - Chassis: GIGABYTE Rack Mount
387         - Motherboard: MT91-FS4-00
388         - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
389         - RAM Memory: 16 * 16GB DIMM
390         - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
391     - NICs configuration:
392         - Numa0:
393             - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
394             - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
395         - Numa1:
396             - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
397             - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
398
399 12. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
400     - Quantity: 2.
401     - Physical connectivity:
402         - IPMI(?) and host management ports.
403         - NIC ports connected into 3-node topology.
404     - Main HW configuration:
405         - Chassis: Huawei TaiShan 2280.
406         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
407         - RAM Memory: 8* 16GB DDR4-2400MT/s
408         - Disks: 1* 4TB SATA HDD
409     - NICs configuration:
410         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
411         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
412
413 13. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
414     - Quantity: 1.
415     - Physical connectivity:
416         - IPMI and host management ports.
417         - NIC ports connected into 2-node topologies.
418     - Main HW configuration:
419         - Chassis: Gigabyte R181-T90 1U
420         - Motherboard: MT91-FS1
421         - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
422         - RAM Memory: 4* 32GB RDIMM
423         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
424     - NICs configuration:
425         - Numa0:
426             - no cards
427         - Numa1:
428             - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
429
430 14. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
431     - Quantity: 2.
432     - Physical connectivity:
433         - IPMI and host management ports.
434         - NIC ports connected into 3-node topologies.
435     - Main HW configuration:
436         - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
437         - Motherboard: Mt.Jade Motherboard
438         - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
439         - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
440         - RAM Memory: 16* 8GB DDR4-3200MT/s
441         - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
442     - NICs configuration:
443         - Numa0: (x16, x16 PCIe4.0 lanes)
444             - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
445             - PCIe Slot8 0001:00:00.x: ConnectX6-2p100GE Mellanox.
446         - Numa1:
447             - no cards.
448
449 15. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build.
450     - Quantity: 2.
451     - Physical connectivity:
452         - IPMI and host management ports.
453     - Main HW configuration:
454         - Chassis: Gigabyte R152-P30-00 1U
455         - Motherboard: MP32-AR1-00
456         - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
457         - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
458         - RAM Memory: 12* 16GB DDR4-3200MT/s
459         - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
460
461 16. **Server-Type-E31**: Purpose - Skylake Xeon Shared TG for FD.io performance testing.
462     - Quantity: 1.
463     - Physical connectivity:
464         - IPMI and host management ports.
465         - NIC ports connected into 2-node and 3-node topologies.
466     - Main HW configuration:
467         - Chassis: SuperMicro SYS-7049GP-TRT.
468         - Motherboard: SuperMicro X11DPG-QT.
469         - Processors: 2* Intel Platinum 8180 2.5 GHz.
470         - RAM Memory: 16* 16GB DDR4-2666MHz.
471         - Disks: 2* 1.6TB 6G SATA SSD.
472     - NICs configuration:
473         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
474             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
475             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
476             - PCIe Slot9 5e:00.xx: empty.
477         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
478             - PCIe Slot6 86:00.xx: empty.
479             - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
480             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
481
482 17. **Server-Type-E32**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
483     - Quantity: 1.
484     - Physical connectivity:
485         - IPMI and host management ports.
486         - NIC ports connected into 2-node and/or 3-node testbed topologies.
487     - Main HW configuration:
488         - Chassis: SuperMicro SYS-740GP-TNRT.
489         - Motherboard: Super X12DPG-QT6.
490         - Processors: 2* Intel Platinum 8358 2.6 GHz.
491         - RAM Memory: 16* 16GB DDR4-3200.
492         - Disks: 2* 960GB SATA SSD.
493     - NICs configuration:
494         - Numa0: (x16, x16, x16 PCIe4.0 lanes)
495             - PCIe Slot2 4b:00.xx: xxv710-DA2-2p25GE Intel.
496             - PCIe Slot4 31:00.xx: xl710-QDA2-2p40GE Intel.
497             - PCIe Slot9 ff:00.xx: empty.
498         - Numa1: (x16, x16, x16 PCIe4.0 lanes)
499             - PCIe Slot6 ca:00.xx: e810-XXVDA4-4p25GE Intel.
500             - PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
501             - PCIe Slot10 ff:00.xx: empty.
502
503 18. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing.
504     - Quantity: 4.
505     - Physical connectivity:
506         - IPMI and host management ports.
507         - NIC ports connected into 2-node topology.
508     - Main HW configuration:
509         - Chassis: SuperMicro SYS-740GP-TNRT.
510         - Motherboard: Super X12DPG-QT6.
511         - Processors: 2* Intel Platinum 8358 2.6 GHz.
512         - RAM Memory: 16* 16GB DDR4-3200.
513         - Disks: 2* 960GB SATA SSD.
514     - NICs configuration:
515         - Numa0: (x16, x16, x16 PCIe4.0 lanes)
516             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
517             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
518             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
519         - Numa1: (x16, x16, x16 PCIe4.0 lanes)
520             - PCIe Slot6 86:00.xx: empty.
521             - PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox.
522             - PCIe Slot10 d8:00.xx: empty.
523
524 19. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing.
525     - Quantity: 4.
526     - Physical connectivity:
527         - IPMI and host management ports.
528         - NIC ports connected into 2-node testbed topologies.
529     - Main HW configuration:
530         - Chassis: SuperMicro SYS-740GP-TNRT.
531         - Motherboard: Super X12DPG-QT6.
532         - Processors: 2* Intel Platinum 8358 2.6 GHz.
533         - RAM Memory: 16* 16GB DDR4-3200.
534         - Disks: 2* 960GB SATA SSD.
535     - NICs configuration:
536         - Numa0: (x16, x16, x16 PCIe4.0 lanes)
537             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
538             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
539             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
540         - Numa1: (x16, x16, x16 PCIe4.0 lanes)
541             - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
542             - PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox.
543             - PCIe Slot10 d8:00.xx: empty.
544
545 20. **Server-Type-F3**: Purpose - Icelake Xeon TG or SUT for FD.io performance testing.
546     - Quantity: 6.
547     - Physical connectivity:
548         - IPMI and host management ports.
549         - NIC ports connected into 3-node testbed topologies.
550     - Main HW configuration:
551         - Chassis: SuperMicro SYS-740GP-TNRT.
552         - Motherboard: Super X12DPG-QT6.
553         - Processors: 2* Intel Platinum 8358 2.6 GHz.
554         - RAM Memory: 16* 16GB DDR4-3200.
555         - Disks: 2* 960GB SATA SSD.
556     - NICs configuration:
557         - Numa0: (x16, x16, x16 PCIe4.0 lanes)
558             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
559             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
560             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
561         - Numa1: (x16, x16, x16 PCIe4.0 lanes)
562             - PCIe Slot6 86:00.xx: ConnectX6-2p100GE Mellanox.
563             - PCIe Slot8 af:00.xx: empty.
564             - PCIe Slot10 d8:00.xx: empty.
565
566 21. **Server-Type-F4**: Purpose - Icelake Xeon TG for FD.io performance testing.
567     - Quantity: 3.
568     - Physical connectivity:
569         - IPMI and host management ports.
570         - NIC ports connected into 3-node testbed topologies.
571     - Main HW configuration:
572         - Chassis: SuperMicro SYS-740GP-TNRT.
573         - Motherboard: Super X12DPG-QT6.
574         - Processors: 2* Intel Platinum 8358 2.6 GHz.
575         - RAM Memory: 16* 16GB DDR4-3200.
576         - Disks: 2* 960GB SATA SSD.
577     - NICs configuration:
578         - Numa0: (x16, x16, x16 PCIe4.0 lanes)
579             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
580             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
581             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
582         - Numa1: (x16, x16, x16 PCIe4.0 lanes)
583             - PCIe Slot6 86:00.xx: ConnectX6-2p100GE Mellanox.
584             - PCIe Slot8 af:00.xx: empty.
585             - PCIe Slot10 d8:00.xx: empty.
586
587 22. **Server-Type-F5**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
588     - Quantity: 2.
589     - Physical connectivity:
590         - IPMI and host management ports.
591         - NIC ports connected into 2-node and/or 3-node testbed topologies.
592     - Main HW configuration:
593         - Chassis: SuperMicro SYS-740GP-TNRT.
594         - Motherboard: Super X12DPG-QT6.
595         - Processors: 2* Intel Platinum 8358 2.6 GHz.
596         - RAM Memory: 16* 16GB DDR4-3200.
597         - Disks: 2* 960GB SATA SSD.
598     - NICs configuration:
599         - Numa0: (x16, x16, x16 PCIe4.0 lanes)
600             - PCIe Slot2 4b:00.xx: xxv710-DA2-2p25GE Intel.
601             - PCIe Slot4 31:00.xx: empty.
602             - PCIe Slot9 ff:00.xx: empty.
603         - Numa1: (x16, x16, x16 PCIe4.0 lanes)
604             - PCIe Slot6 ca:00.xx: e810-XXVDA4-4p25GE Intel.
605             - PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
606             - PCIe Slot10 ff:00.xx: empty.
607
608 23. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing.
609     - Quantity: 2
610     - Physical connectivity:
611         - IPMI and host management ports.
612         - NIC ports connected into 3-node testbed topology.
613     - Main HW configuration:
614         - Chassis: Intel JACOBSVILLE SDP.
615         - Motherboard: Intel JACOBSVILLE E63448-400.
616         - Processors: 1* Intel Atom P5362B 2.2 GHz.
617         - RAM Memory: 2* 16GB DDR4-2933.
618         - Disks: ?* ? SATA SSD.
619     - NICs configuration:
620         - Numa0: (x16, PCIe3.0 lane)
621             - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
622
623 24. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
624     - Quantity: 1.
625     - Physical connectivity:
626         - IPMI and host management ports.
627         - NIC ports connected into 3-numa-node testbed topologies.
628     - Main HW configuration:
629         - Chassis: SuperMicro SYS-741GE-TNRT.
630         - Motherboard: Super X13DEG-QT-P.
631         - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
632         - RAM Memory: 16* 32GB DDR5-4800.
633         - Disks: 2* 960GB SATA SSD.
634     - NICs configuration:
635         - Numa0: (x16, x16, x16 PCIe5.0 lanes)
636             - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
637             - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
638             - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
639         - Numa1: (x16, x16, x16 PCIe5.0 lanes)
640             - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
641             - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
642             - PCIe Slot11 d8:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
643
644 25. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
645     - Quantity: 1.
646     - Physical connectivity:
647         - IPMI and host management ports.
648         - NIC ports connected into 3-numa-node testbed topologies.
649     - Main HW configuration:
650         - Chassis: SuperMicro SYS-741GE-TNRT.
651         - Motherboard: Super X13DEG-QT-P.
652         - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
653         - RAM Memory: 16* 32GB DDR5-4800.
654         - Disks: 2* 960GB SATA SSD.
655     - NICs configuration:
656         - Numa0: (x16, x16, x16 PCIe5.0 lanes)
657             - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
658             - PCIe Slot4 3b:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
659             - PCIe Slot10 5e:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
660         - Numa1: (x16, x16, x16 PCIe5.0 lanes)
661             - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
662             - PCIe Slot9 af:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
663             - PCIe Slot11 d8:00.xx: empty.
664
665 26. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
666     - Quantity: 1.
667     - Physical connectivity:
668         - IPMI and host management ports.
669         - NIC ports connected into 3-numa-node testbed topologies.
670     - Main HW configuration:
671         - Chassis: SuperMicro SYS-741GE-TNRT.
672         - Motherboard: Super X13DEG-QT-P.
673         - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
674         - RAM Memory: 16* 32GB DDR5-4800.
675         - Disks: 2* 960GB SATA SSD.
676     - NICs configuration:
677         - Numa0: (x16, x16, x16 PCIe5.0 lanes)
678             - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
679             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
680             - PCIe Slot10 5e:00.xx: empty.
681         - Numa1: (x16, x16, x16 PCIe5.0 lanes)
682             - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel.
683             - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
684             - PCIe Slot11 d8:00.xx: empty.
685
686 27. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
687     - Quantity: 1.
688     - Physical connectivity:
689         - IPMI and host management ports.
690         - NIC ports connected into 3-numa-node testbed topologies.
691     - Main HW configuration:
692         - Chassis: SuperMicro SYS-741GE-TNRT.
693         - Motherboard: Super X13DEG-QT-P.
694         - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
695         - RAM Memory: 16* 32GB DDR5-4800.
696         - Disks: 2* 960GB SATA SSD.
697     - NICs configuration:
698         - Numa0: (x16, x16, x16 PCIe5.0 lanes)
699             - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
700             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
701             - PCIe Slot10 5e:00.xx: empty.
702         - Numa1: (x16, x16, x16 PCIe5.0 lanes)
703             - PCIe Slot7 86:00.xx: empty.
704             - PCIe Slot9 af:00.xx: empty.
705             - PCIe Slot11 d8:00.xx: empty.
706
707 28. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
708     - Quantity: 2.
709     - Physical connectivity:
710         - IPMI and host management ports.
711         - NIC ports connected into 2-node testbed topologies.
712     - Main HW configuration:
713         - Chassis: SuperMicro SYS-741GE-TNRT.
714         - Motherboard: Super X13DEG-QT-P.
715         - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
716         - RAM Memory: 16* 32GB DDR5-4800.
717         - Disks: 2* 960GB SATA SSD.
718     - NICs configuration:
719         - Numa0: (x16, x16, x16 PCIe5.0 lanes)
720             - PCIe Slot2 3d:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
721             - PCIe Slot4 2c:00.xx: e810-2CQDA2-2p100GE Intel.
722             - PCIe Slot10 17:00.xx: e810-XXVDA4-4p25GE Intel.
723         - Numa1: (x16, x16, x16 PCIe5.0 lanes)
724             - PCIe Slot7 86:00.xx: empty.
725             - PCIe Slot9 af:00.xx: empty.
726             - PCIe Slot11 d8:00.xx: empty.
727
728 29. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
729     - Quantity: 2.
730     - Physical connectivity:
731         - IPMI and host management ports.
732         - NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test.
733     - Main HW configuration:
734         - Chassis: SuperMicro SYS-741GE-TNRT.
735         - Motherboard: Super X13DEG-QT-P.
736         - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
737         - RAM Memory: 16* 32GB DDR5-4800.
738         - Disks: 2* 960GB SATA SSD.
739     - NICs configuration:
740         - Numa0: (x16, x16, x16 PCIe5.0 lanes)
741             - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
742             - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
743             - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
744         - Numa1: (x16, x16, x16 PCIe5.0 lanes)
745             - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
746             - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
747             - PCIe Slot11 d8:00.xx: empty.
748
749 30. **Server-Type-H7**: Purpose - SapphireRapids SUT for FD.io VPP_Device functional tests.
750     - Quantity: 2.
751     - Physical connectivity:
752         - IPMI and host management ports.
753         - NIC ports connected into 1-node topologies.
754     - Main HW configuration:
755         - Chassis: SuperMicro SYS-741GE-TNRT.
756         - Motherboard: Super X13DEG-QT-P.
757         - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
758         - RAM Memory: 16* 32GB DDR5-4800.
759         - Disks: 2* 960GB SATA SSD.
760     - NICs configuration:
761         - Numa0: (x16, x16, x16 PCIe5.0 lanes)
762             - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
763             - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
764             - PCIe Slot10 5e:00.xx: empty.
765         - Numa1: (x16, x16, x16 PCIe5.0 lanes)
766             - PCIe Slot7 86:00.xx: empty.
767             - PCIe Slot9 af:00.xx: empty.
768             - PCIe Slot11 d8:00.xx: empty.
769
770 ## Testbeds Configuration
771
772 ### 1-Node-Skylake (1n-skx)
773
774 ```
775 - SUT [Server-Type-B6]:
776     - testbedname: testbed11.
777     - hostname: s1-t11-sut1.
778     - IPMI IP: 10.30.50.47
779     - Host IP: 10.30.51.50
780     - portnames:
781         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
782         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
783         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
784         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
785         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
786         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
787         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
788         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
789         - s1-t11-sut1-c5/p1 - 100GE-port1 e810-2p100GE.
790         - s1-t11-sut1-c5/p2 - 100GE-port2 e810-2p100GE.
791         - s1-t11-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
792         - s1-t11-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
793 - SUT [Server-Type-B6]:
794     - testbedname: testbed12.
795     - hostname: s2-t12-sut1.
796     - IPMI IP: 10.30.50.48
797     - Host IP: 10.30.51.51
798     - portnames:
799         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
800         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
801         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
802         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
803         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
804         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
805         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
806         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
807         - s2-t12-sut1-c5/p1 - 100GE-port1 e810-2p100GE.
808         - s2-t12-sut1-c5/p2 - 100GE-port2 e810-2p100GE.
809         - s2-t12-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
810         - s2-t12-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
811 ```
812
813 ### 1-Node-ThunderX2 (1n-tx2)
814
815 ```
816 - SUT [Server-Type-E11]:
817     - testbedname: testbed13
818     - hostname: s55-t13-sut1
819     - IPMI IP: 10.30.50.70
820     - Host IP: 10.30.51.70
821     - portnames:
822         - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
823         - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
824         - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
825         - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
826         - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
827         - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
828         - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
829         - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
830 - SUT [Server-Type-E11]:
831     - testbedname: testbed14
832     - hostname: s56-t14-sut1
833     - IPMI IP: 10.30.50.71
834     - Host IP: 10.30.51.71
835     - portnames:
836         - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
837         - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
838         - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
839         - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
840         - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
841         - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
842         - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
843         - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
844 ```
845
846 ### 1-Node-SapphireRapids (1n-spr)
847
848 ```
849 - SUT [Server-Type-H7]:
850     - testbedname: testbed15.
851     - hostname: s30-t15-sut1.
852     - IPMI IP: 10.30.50.30
853     - Host IP: 10.30.51.31
854     - portnames:
855         - s30-t15-sut1-c1/p1 - 100GE-port1 e810-2p100GE.
856         - s30-t15-sut1-c1/p2 - 100GE-port2 e810-2p100GE.
857         - s30-t15-sut1-c2/p1 - 100GE-port1 e810-2p100GE.
858         - s30-t15-sut1-c2/p2 - 100GE-port1 e810-2p100GE.
859 - SUT [Server-Type-H7]:
860     - testbedname: testbed16.
861     - hostname: s31-t16-sut1.
862     - IPMI IP: 10.30.50.31
863     - Host IP: 10.30.51.31
864     - portnames:
865         - s31-t16-sut1-c1/p1 - 100GE-port1 e810-2p100GE.
866         - s31-t16-sut1-c1/p2 - 100GE-port2 e810-2p100GE.
867         - s31-t16-sut1-c2/p1 - 100GE-port1 e810-2p100GE.
868         - s31-t16-sut1-c2/p2 - 100GE-port1 e810-2p100GE.
869 ```
870
871 ### 1-Node-Cascadelake (1n-clx)
872
873 ```
874 - SUT [Server-Type-C1]:
875     - testbedname: testbed11.
876     - hostname: s32-t14-sut1.
877     - IPMI IP: 10.30.55.17
878     - Host IP: 10.32.8.17
879     - portnames:
880         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
881         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
882         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
883         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
884         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
885         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
886         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
887         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
888 ```
889
890 ### 2-Node-IxiaPS1L47 (2n-ps1)
891
892 ```
893 - SUT [Server-Type-B8]:
894     - testbedname: testbed25.
895     - hostname: s25-t25-sut1.
896     - IPMI IP: 10.30.50.58
897     - Host IP: 10.30.51.61
898     - portnames:
899         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
900         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
901         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
902         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
903 - TG [Server-Type-B7]:
904     - testbedname: testbed25.
905     - hostname: s26-t25-tg1.
906     - IPMI IP: 10.30.50.59
907     - Host IP: 10.30.51.62
908     - portnames:
909         - s26-t25-tg1-p1 - 10GE-port1.
910         - s26-t25-tg1-p2 - 10GE-port2.
911         - s26-t25-tg1-p3 - 10GE-port3.
912         - s26-t25-tg1-p4 - 10GE-port4.
913 ```
914
915 ### 2-Node-Cascadelake (2n-clx)
916
917 {{< figure src="/cdocs/testbed-2n-clx.svg" >}}
918
919 ```
920 - SUT [Server-Type-C2]:
921     - testbedname: testbed27.
922     - hostname: s33-t27-sut1.
923     - IPMI IP: 10.30.55.18
924     - Host IP: 10.32.8.18
925     - portnames:
926         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
927         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
928         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
929         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
930         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
931         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
932         - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
933         - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
934         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
935         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
936 - TG [Server-Type-C3]:
937     - testbedname: testbed27.
938     - hostname: s34-t27-tg1.
939     - IPMI IP: 10.30.55.19
940     - Host IP: 10.32.8.19
941     - portnames:
942         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
943         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
944         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
945         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
946         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
947         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
948         - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
949         - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
950         - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
951         - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
952         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
953         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
954 - SUT [Server-Type-C2]:
955     - testbedname: testbed28.
956     - hostname: s35-t28-sut1.
957     - IPMI IP: 10.30.55.20
958     - Host IP: 10.32.8.20
959     - portnames:
960         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
961         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
962         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
963         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
964         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
965         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
966         - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
967         - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
968         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
969         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
970 - TG [Server-Type-C3]:
971     - testbedname: testbed28.
972     - hostname: s36-t28-tg1.
973     - IPMI IP: 10.30.55.21
974     - Host IP: 10.32.8.21
975     - portnames:
976         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
977         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
978         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
979         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
980         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
981         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
982         - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
983         - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
984         - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
985         - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
986         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
987         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
988 - SUT [Server-Type-C2]:
989     - testbedname: testbed29.
990     - hostname: s37-t29-sut1.
991     - IPMI IP: 10.30.55.22
992     - Host IP: 10.32.8.22
993     - portnames:
994         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
995         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
996         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
997         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
998         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
999         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1000         - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1001         - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1002         - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1003         - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1004 - TG [Server-Type-C3]:
1005     - testbedname: testbed29.
1006     - hostname: s38-t29-tg1.
1007     - IPMI IP: 10.30.55.23
1008     - Host IP: 10.32.8.23
1009     - portnames:
1010         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1011         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1012         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1013         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1014         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1015         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1016         - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1017         - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1018         - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1019         - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1020 ```
1021
1022 ### 2-Node-Zen2 (2n-zn2)
1023
1024 {{< figure src="/cdocs/testbed-2n-zn2.svg" >}}
1025
1026 ```
1027 - SUT [Server-Type-D1]:
1028     - testbedname: testbed210.
1029     - hostname: s60-t210-sut1.
1030     - IPMI IP: 10.30.55.24
1031     - Host IP: 10.32.8.24
1032     - portnames:
1033         - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1034         - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1035         - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1036         - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1037         - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1038         - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1039         - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1040         - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1041 - TG [Server-Type-D2]:
1042     - testbedname: testbed210.
1043     - hostname: s61-t210-tg1.
1044     - IPMI IP: 10.30.55.25
1045     - Host IP: 10.32.8.25
1046     - portnames:
1047         - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1048         - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1049         - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1050         - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1051         - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1052         - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1053         - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1054         - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1055 ```
1056
1057 ### 2-Node-ThunderX2 (2x-tx2)
1058
1059 {{< figure src="/cdocs/testbed-2n-tx2.svg" >}}
1060
1061 ```
1062 - SUT [Server-Type-E22]:
1063     - testbedname: testbed211.
1064     - hostname: s27-t211-sut1.
1065     - IPMI IP: 10.30.50.69
1066     - Host IP: 10.30.51.69
1067     - portnames:
1068         - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1069         - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1070 - TG [Server-Type-E31]:
1071     - testbedname: testbed33 and testbed211.
1072     - hostname: s19-t33t211-tg1.
1073     - IPMI IP: 10.30.50.46
1074     - Host IP: 10.30.51.49
1075     - portnames:
1076         - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1077         - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1078         - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1079         - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1080         - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1081         - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1082         - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1083         - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1084         - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1085         - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1086         - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1087         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1088 ```
1089
1090 ### 2-Node-Icelake (2n-icx)
1091
1092 {{< figure src="/cdocs/testbed-2n-icx.svg" >}}
1093
1094 ```
1095 - SUT [Server-Type-F1]:
1096     - testbedname: testbed212.
1097     - hostname: s71-t212-sut1.
1098     - IPMI IP: 10.30.50.81
1099     - Host IP: 10.30.51.81
1100     - portnames:
1101         - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1102         - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1103         - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1104         - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1105         - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1106         - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1107         - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1108         - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1109         - s71-t212-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1110         - s71-t212-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1111 - TG [Server-Type-F2]:
1112     - testbedname: testbed212.
1113     - hostname: s72-t212-tg1.
1114     - IPMI IP: 10.30.50.82
1115     - Host IP: 10.30.51.82
1116     - portnames:
1117         - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1118         - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1119         - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1120         - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1121         - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1122         - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1123         - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1124         - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1125         - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1126         - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1127         - s72-t212-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1128         - s72-t212-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1129 - SUT [Server-Type-F1]:
1130     - testbedname: testbed213.
1131     - hostname: s83-t213-sut1.
1132     - IPMI IP: 10.30.50.83
1133     - Host IP: 10.30.51.83
1134     - portnames:
1135         - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1136         - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1137         - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1138         - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1139         - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1140         - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1141         - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1142         - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1143         - s83-t213-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1144         - s83-t213-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1145 - TG [Server-Type-F2]:
1146     - testbedname: testbed213.
1147     - hostname: s84-t213-tg1.
1148     - IPMI IP: 10.30.50.84
1149     - Host IP: 10.30.51.84
1150     - portnames:
1151         - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1152         - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1153         - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1154         - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1155         - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1156         - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1157         - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1158         - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1159         - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1160         - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1161         - s84-t213-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1162         - s84-t213-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1163 - SUT [Server-Type-F1]:
1164     - testbedname: testbed214.
1165     - hostname: s85-t214-sut1.
1166     - IPMI IP: 10.30.50.85
1167     - Host IP: 10.30.51.85
1168     - portnames:
1169         - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1170         - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1171         - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1172         - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1173         - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1174         - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1175         - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1176         - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1177         - s85-t214-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1178         - s85-t214-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1179 - TG [Server-Type-F2]:
1180     - testbedname: testbed214.
1181     - hostname: s86-t214-tg1.
1182     - IPMI IP: 10.30.50.86
1183     - Host IP: 10.30.51.86
1184     - portnames:
1185         - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1186         - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1187         - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1188         - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1189         - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1190         - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1191         - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1192         - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1193         - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1194         - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1195         - s86-t214-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1196         - s86-t214-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1197 - SUT [Server-Type-F1]:
1198     - testbedname: testbed215.
1199     - hostname: s87-t215-sut1.
1200     - IPMI IP: 10.30.50.87
1201     - Host IP: 10.30.51.87
1202     - portnames:
1203         - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1204         - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1205         - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1206         - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1207         - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1208         - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1209         - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1210         - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1211         - s87-t215-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1212         - s87-t215-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1213 - TG [Server-Type-F2]:
1214     - testbedname: testbed215.
1215     - hostname: s88-t215-tg1.
1216     - IPMI IP: 10.30.50.88
1217     - Host IP: 10.30.51.88
1218     - portnames:
1219         - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1220         - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1221         - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1222         - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1223         - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1224         - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1225         - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1226         - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1227         - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1228         - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1229         - s88-t215-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1230         - s88-t215-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1231 ```
1232
1233 ### 3-Node-Rangeley (3n-rng)
1234
1235 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1236
1237 ```
1238 - ServerB22 [Server-Type-B5]:
1239     - testbedname: testbed35.
1240     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1241     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1242     - Host IP: 10.30.51.9
1243     - portnames:
1244         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1245         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1246     - 1GB ports (tbd)
1247 - ServerB23 [Server-Type-B5]:
1248     - testbedname: testbed35.
1249     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1250     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1251     - Host IP: 10.30.51.10
1252     - portnames:
1253         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1254         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1255     - 1GB ports (tbd)
1256 - ServerB24 [Server-Type-B5]:
1257     - testbedname: testbed35.
1258     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1259     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1260     - Host IP: 10.30.51.11
1261     - portnames:
1262         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1263         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1264     - 1GB ports (tbd)
1265 ```
1266
1267 ### 3-Node-Taishan (3n-tsh)
1268
1269 {{< figure src="/cdocs/testbed-3n-tsh.svg" >}}
1270
1271 ```
1272 - SUT [Server-Type-E21]:
1273     - testbedname: testbed33.
1274     - hostname: s17-t33-sut1.
1275     - IPMI IP: 10.30.50.36
1276     - Host IP: 10.30.51.36
1277     - portnames:
1278         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1279         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1280         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1281         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1282 - SUT [Server-Type-E21]:
1283     - testbedname: testbed33.
1284     - hostname: s18-t33-sut2.
1285     - IPMI IP: 10.30.50.37
1286     - Host IP: 10.30.51.37
1287     - portnames:
1288         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1289         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1290         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1291         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1292 - TG [Server-Type-E31]:
1293     - testbedname: testbed33 and testbed211.
1294     - hostname: s19-t33t211-tg1.
1295     - IPMI IP: 10.30.50.46
1296     - Host IP: 10.30.51.49
1297     - portnames:
1298         - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1299         - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1300         - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1301         - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1302         - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1303         - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1304         - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1305         - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1306         - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1307         - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1308         - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1309         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1310 ```
1311
1312 ### 3-Node-Altra (3n-alt)
1313
1314 {{< figure src="/cdocs/testbed-3n-alt.svg" >}}
1315
1316 ```
1317 - SUT [Server-Type-E23]:
1318     - testbedname: testbed34.
1319     - hostname: s62-t34-sut1.
1320     - IPMI IP: 10.30.50.72
1321     - Host IP: 10.30.51.72
1322     - portnames:
1323         - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1324         - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1325         - s62-t34-sut1-c8/p1 - 100GE-port1 ConnectX6-2p100GE.
1326         - s62-t34-sut1-c8/p2 - 100GE-port2 ConnectX6-2p100GE.
1327 - SUT [Server-Type-E23]:
1328     - testbedname: testbed34.
1329     - hostname: s63-t34-sut2.
1330     - IPMI IP: 10.30.50.73
1331     - Host IP: 10.30.51.73
1332     - portnames:
1333         - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1334         - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1335         - s63-t34-sut2-c8/p1 - 100GE-port1 ConnectX6-2p100GE.
1336         - s63-t34-sut2-c8/p2 - 100GE-port2 ConnectX6-2p100GE.
1337 - TG [Server-Type-E32]:
1338     - testbedname: testbed34.
1339     - hostname: s64-t34-tg1.
1340     - IPMI IP: 10.30.50.74
1341     - Host IP: 10.30.51.74
1342     - portnames:
1343         - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1344         - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1345         - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1346         - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1347         - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1348         - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1349         - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1350         - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1351         - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1352         - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1353 ```
1354
1355 ### 3-Node-Icelake (3n-icx)
1356
1357 {{< figure src="/cdocs/testbed-3n-icx.svg" >}}
1358
1359 ```
1360 - SUT1 [Server-Type-F3]:
1361     - testbedname: testbed37.
1362     - hostname: s65-t37-sut1.
1363     - IPMI IP: 10.30.50.75
1364     - Host IP: 10.30.51.75
1365     - portnames:
1366         - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1367         - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1368         - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1369         - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1370         - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1371         - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1372         - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1373         - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1374         - s65-t37-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
1375         - s65-t37-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
1376 - SUT2 [Server-Type-F3]:
1377     - testbedname: testbed37.
1378     - hostname: s66-t37-sut2.
1379     - IPMI IP: 10.30.50.76
1380     - Host IP: 10.30.51.76
1381     - portnames:
1382         - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1383         - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1384         - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1385         - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1386         - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1387         - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1388         - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1389         - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1390         - s65-t37-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
1391         - s65-t37-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
1392 - TG [Server-Type-F3]:
1393     - testbedname: testbed37.
1394     - hostname: s67-t37-tg1.
1395     - IPMI IP: 10.30.50.77
1396     - Host IP: 10.30.51.77
1397     - portnames:
1398         - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1399         - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1400         - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1401         - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1402         - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1403         - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1404         - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1405         - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1406         - s67-t37-tg1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
1407         - s67-t37-tg1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
1408 - SUT1 [Server-Type-F3]:
1409     - testbedname: testbed38.
1410     - hostname: s78-t38-sut1.
1411     - IPMI IP: 10.30.50.78
1412     - Host IP: 10.30.51.78
1413     - portnames:
1414         - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1415         - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1416         - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1417         - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1418         - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1419         - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1420         - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1421         - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1422         - s78-t38-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
1423         - s78-t38-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
1424 - SUT2 [Server-Type-F3]:
1425     - testbedname: testbed38.
1426     - hostname: s79-t38-sut2.
1427     - IPMI IP: 10.30.50.79
1428     - Host IP: 10.30.51.79
1429     - portnames:
1430         - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1431         - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1432         - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1433         - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1434         - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1435         - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1436         - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1437         - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1438         - s79-t38-sut2-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
1439         - s79-t38-sut2-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
1440 - TG [Server-Type-F3]:
1441     - testbedname: testbed38.
1442     - hostname: s80-t38-tg1.
1443     - IPMI IP: 10.30.50.80
1444     - Host IP: 10.30.51.80
1445     - portnames:
1446         - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1447         - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1448         - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1449         - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1450         - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1451         - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1452         - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1453         - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1454         - s80-t38-tg1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
1455         - s80-t38-tg1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
1456 ```
1457
1458 ### 3-Node-SnowRidge (3n-snr)
1459
1460 {{< figure src="/cdocs/testbed-3n-snr.svg" >}}
1461
1462 ```
1463 - ServerG1 [Server-Type-G1]:
1464     - testbedname: testbed39.
1465     - hostname: s93-t39-sut1.
1466     - IPMI IP: 10.30.50.93
1467     - Host IP: 10.30.51.93
1468     - portnames:
1469         - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1470         - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1471         - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
1472         - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
1473 - ServerG1 [Server-Type-G1]:
1474     - testbedname: testbed39.
1475     - hostname: s94-t39-sut2.
1476     - IPMI IP: 10.30.50.94
1477     - Host IP: 10.30.51.94
1478     - portnames:
1479         - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1480         - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1481         - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1482         - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1483 - ServerF4 [Server-Type-F5]:
1484     - testbedname: testbed39.
1485     - hostname: s89-t39t310-tg1.
1486     - IPMI IP: 10.30.50.89
1487     - Host IP: 10.30.51.89
1488     - portnames:
1489         - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1490         - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1491         - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1492         - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1493 ```
1494
1495 ### 2-Node-SapphireRapids (2n-spr)
1496
1497 {{< figure src="/cdocs/testbed-2n-spr.svg" >}}
1498
1499 ```
1500 - SUT [Server-Type-H1]:
1501     - testbedname: testbed21.
1502     - hostname: s52-t21-sut1.
1503     - IPMI IP: 10.30.50.52
1504     - Host IP: 10.30.51.52
1505     - portnames:
1506         - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
1507         - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
1508         - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
1509         - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
1510         - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1511         - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1512         - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
1513         - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
1514         - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1515         - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1516 - TG [Server-Type-H2]:
1517     - testbedname: testbed21.
1518     - hostname: s53-t21-tg1.
1519     - IPMI IP: 10.30.50.53
1520     - Host IP: 10.30.51.53
1521     - portnames:
1522         - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
1523         - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
1524         - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
1525         - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
1526         - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1527         - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1528         - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
1529         - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
1530         - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1531         - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1532 - SUT [Server-Type-H3]:
1533     - testbedname: testbed22.
1534     - hostname: s54-t22-sut1.
1535     - IPMI IP: 10.30.50.54
1536     - Host IP: 10.30.51.54
1537     - portnames:
1538         - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1539         - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1540         - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1541         - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1542         - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1543         - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1544         - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1545         - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1546         - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1547         - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1548         - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1549         - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1550 - TG [Server-Type-H4]:
1551     - testbedname: testbed22.
1552     - hostname: s55-t22-tg1.
1553     - IPMI IP: 10.30.50.55
1554     - Host IP: 10.30.51.55
1555     - portnames:
1556         - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1557         - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1558         - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1559         - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1560         - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1561         - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1562 - SUT [Server-Type-H5]:
1563     - testbedname: testbed23.
1564     - hostname: s56-t23-sut1.
1565     - IPMI IP: 10.30.50.56
1566     - Host IP: 10.30.51.56
1567     - portnames:
1568         - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1569         - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1570         - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1571         - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1572         - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1573         - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1574         - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1575         - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1576 - TG [Server-Type-H6]:
1577     - testbedname: testbed23.
1578     - hostname: s57-t23-tg1.
1579     - IPMI IP: 10.30.50.57
1580     - Host IP: 10.30.51.57
1581     - portnames:
1582         - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1583         - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1584         - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1585         - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1586         - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1587         - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1588         - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1589         - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1590         - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1591         - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1592         - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1593         - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1594 - SUT [Server-Type-H5]:
1595     - testbedname: testbed24.
1596     - hostname: s58-t24-sut1.
1597     - IPMI IP: 10.30.50.58
1598     - Host IP: 10.30.51.58
1599     - portnames:
1600         - s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1601         - s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1602         - s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1603         - s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1604         - s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1605         - s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1606         - s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1607         - s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1608 - TG [Server-Type-H6]:
1609     - testbedname: testbed24.
1610     - hostname: s59-t24-tg1.
1611     - IPMI IP: 10.30.50.59
1612     - Host IP: 10.30.51.59
1613     - portnames:
1614         - s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1615         - s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1616         - s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1617         - s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1618         - s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1619         - s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1620         - s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1621         - s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1622         - s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1623         - s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1624         - s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1625         - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1626 ```
1627
1628 ## Testbed Wiring
1629
1630 ### 1-Node-Skylake (1n-skx)
1631
1632 ```
1633 - testbed11:
1634     - ring1 10GE-ports x710-4p10GE:
1635         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1636     - ring2 10GE-ports x710-4p10GE:
1637         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1638     - ring3 10GE-ports x710-4p10GE:
1639         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1640     - ring4 10GE-ports x710-4p10GE:
1641         - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1642     - ring5 100GE-ports e810-2p100GE:
1643         - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1644     - ring6 100GE-ports e810-2p100GE:
1645         - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1646 - testbed12:
1647     - ring1 10GE-ports x710-4p10GE:
1648         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1649     - ring2 10GE-ports x710-4p10GE:
1650         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1651     - ring3 10GE-ports x710-4p10GE:
1652         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1653     - ring4 10GE-ports x710-4p10GE:
1654         - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1655     - ring5 100GE-ports e810-2p100GE:
1656         - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1657     - ring6 100GE-ports e810-2p100GE:
1658         - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1659 ```
1660
1661 ### 1-Node-ThunderX2 (1n-tx2)
1662
1663 ```
1664 - testbed13:
1665     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1666         - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1667     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1668         - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1669     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1670         - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1671     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1672         - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1673
1674 - testbed14:
1675     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1676         - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1677     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1678         - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1679     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1680         - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1681     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1682         - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1683 ```
1684
1685 ### 1-Node-SapphireRapids (1n-spr)
1686
1687 ```
1688 - testbed15:
1689     - ring1 100GE-ports e810-2p100GE:
1690         - s30-t15-sut1-c1/p1 to s30-t15-sut1-c2/p1.
1691     - ring2 100GE-ports e810-2p100GE:
1692         - s30-t15-sut1-c1/p2 to s30-t15-sut1-c2/p2.
1693 - testbed16:
1694     - ring1 100GE-ports e810-2p100GE:
1695         - s31-t16-sut1-c1/p1 to s31-t16-sut1-c2/p1.
1696     - ring2 100GE-ports e810-2p100GE:
1697         - s31-t16-sut1-c1/p2 to s31-t16-sut1-c2/p2.
1698 ```
1699
1700 ### 2-Node-IxiaPS1L47 (2n-ps1)
1701
1702 ```
1703 - testbed25:
1704     - link1 10GE-port x710-4p10GE on SUT:
1705         - t25-tg1-p1 to t25-sut1-c2/p1.
1706     - link2 10GE-port x710-4p10GE on SUT:
1707         - t25-tg1-p2 to t25-sut1-c2/p2.
1708     - link3 10GE-port x710-4p10GE on SUT:
1709         - t25-tg1-p3 to t25-sut1-c2/p3.
1710     - link4 10GE-port x710-4p10GE on SUT:
1711         - t25-tg1-p4 to t25-sut1-c2/p4.
1712 ```
1713
1714 ### 2-Node-Cascadelake (2n-clx)
1715
1716 ```
1717 - testbed27:
1718     - ring1 10GE-ports x710-4p10GE on SUT:
1719         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1720         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1721     - ring2 10GE-ports x710-4p10GE on SUT:
1722         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1723         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1724     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1725         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1726         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1727     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1728         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1729         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1730     - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1731         - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1732         - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1733     - ring6 100GE-ports e810-2p100GE on TG:
1734         - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
1735         - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
1736 - testbed28:
1737     - ring1 10GE-ports x710-4p10GE on SUT:
1738         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1739         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1740     - ring2 10GE-ports x710-4p10GE on SUT:
1741         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1742         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1743     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1744         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1745         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1746     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1747         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1748         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1749     - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1750         - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1751         - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1752     - ring6 100GE-ports e810-2p100GE on TG:
1753         - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
1754         - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
1755 - testbed29:
1756     - ring1 10GE-ports x710-4p10GE on SUT:
1757         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1758         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1759     - ring2 10GE-ports x710-4p10GE on SUT:
1760         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1761         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1762     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1763         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1764         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1765     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1766         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1767         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1768     - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1769         - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1770         - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1771 ```
1772
1773 ### 2-Node-Zen2 (2n-zn2)
1774
1775 ```
1776 - testbed210:
1777     - ring1 10GE-ports x710-4p10GE on SUT:
1778         - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1779         - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1780     - ring2 10GE-ports x710-4p10GE on SUT:
1781         - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1782         - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1783     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1784         - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1785         - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1786     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1787         - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1788         - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1789 ```
1790
1791 ### 2-Node-ThunderX2 (2n-tx2)
1792
1793 ```
1794 - testbed211:
1795     - ring1 10GE-ports x520-2p10GE on SUTs:
1796         - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
1797         - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
1798 ```
1799
1800 ### 2-Node-Icelake (2n-icx)
1801
1802 ```
1803 - testbed212:
1804     - ring1 25GE-ports xxv710-DA2-2p25GE:
1805         - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
1806         - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
1807     - ring2 25GE-ports e810-XXVDA4-2p25GE:
1808         - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
1809         - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
1810         - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
1811         - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
1812     - ring3 100GE-ports e810-2CQDA2-2p100GE:
1813         - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
1814         - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
1815     - ring4 100GE-ports e810-2CQDA2-2p100GE:
1816         - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
1817         - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
1818     - ring5 200GE-ports ConnectX7-2p200GE:
1819         - s72-t212-tg1-c8/p1 to s71-t212-sut1-c8/p1.
1820         - s71-t212-sut1-c8/p2 to s72-t212-tg1-c8/p2.
1821 - testbed213:
1822     - ring1 25GE-ports xxv710-DA2-2p25GE:
1823         - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
1824         - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
1825     - ring2 25GE-ports e810-XXVDA4-2p25GE:
1826         - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
1827         - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
1828         - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
1829         - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
1830     - ring3 100GE-ports e810-2CQDA2-2p100GE:
1831         - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
1832         - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
1833     - ring4 100GE-ports e810-2CQDA2-2p100GE:
1834         - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
1835         - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
1836     - ring5 200GE-ports ConnectX7-2p200GE:
1837         - s84-t213-tg1-c8/p1 to s83-t213-sut1-c8/p1.
1838         - s83-t213-sut1-c8/p2 to s84-t213-tg1-c8/p2.
1839 - testbed214:
1840     - ring1 25GE-ports xxv710-DA2-2p25GE:
1841         - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
1842         - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
1843     - ring2 25GE-ports e810-XXVDA4-2p25GE:
1844         - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
1845         - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
1846         - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
1847         - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
1848     - ring3 100GE-ports e810-2CQDA2-2p100GE:
1849         - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
1850         - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
1851     - ring4 100GE-ports e810-2CQDA2-2p100GE:
1852         - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
1853         - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
1854     - ring5 200GE-ports ConnectX7-2p200GE:
1855         - s86-t214-tg1-c8/p1 to s85-t214-sut1-c8/p1.
1856         - s85-t214-sut1-c8/p2 to s86-t214-tg1-c8/p2.
1857 - testbed215:
1858     - ring1 25GE-ports xxv710-DA2-2p25GE:
1859         - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
1860         - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
1861     - ring2 25GE-ports e810-XXVDA4-2p25GE:
1862         - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
1863         - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
1864         - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
1865         - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
1866     - ring3 100GE-ports e810-2CQDA2-2p100GE:
1867         - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
1868         - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
1869     - ring4 100GE-ports e810-2CQDA2-2p100GE:
1870         - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
1871         - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
1872     - ring5 200GE-ports ConnectX7-2p200GE:
1873         - s88-t215-tg1-c8/p1 to s87-t215-sut1-c8/p1.
1874         - s87-t215-sut1-c8/p2 to s88-t215-tg1-c8/p2.
1875 ```
1876
1877 ### 3-Node-Rangeley (3n-rng)
1878
1879 ```
1880 To be completed.
1881 ```
1882
1883 ### 3-Node-Taishan (3n-tsh)
1884
1885 ```
1886 - testbed33:
1887     - ring1 10GE-ports x520-2p10GE on SUTs:
1888         - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1889         - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1890         - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
1891     - ring2 25GE-ports cx4-2p25GE on SUTs:
1892         - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1893         - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1894         - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
1895 ```
1896
1897 ### 3-Node-Altra (3n-alt)
1898
1899 ```
1900 - testbed34:
1901     - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
1902         - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
1903         - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
1904         - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
1905     - ring2 100GE-ports ConnectX6-2p100GE Mellanox on SUTs:
1906         - s64-t34-tg1-c8/p1 - s62-t34-sut2-c8/p1.
1907         - s62-t34-sut1-c8/p1 - s63-t34-sut2-c8/p2.
1908         - s63-t34-sut1-c8/p2 - s64-t34-tg1-c8/p2.
1909 ```
1910
1911 ### 3-Node-Icelake (3n-icx)
1912
1913 ```
1914 - testbed37:
1915     - ring1 25GE-ports xxv710-DA2-2p25GE:
1916         - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
1917         - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
1918         - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
1919     - ring2 25GE-ports e810-XXVDA4-4p25GE:
1920         - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
1921         - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
1922         - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
1923         - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
1924         - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
1925         - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
1926     - ring3 100GE-ports e810-2CQDA2-2p100GE:
1927         - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
1928         - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
1929         - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
1930     - ring4 200GE-ports ConnectX6-2p200GE:
1931         - s67-t37-tg1-c10/p1 - s65-t37-sut1-c10/p2.
1932         - s65-t37-sut1-c10/p1 - s66-t37-sut2-c10/p2.
1933         - s66-t37-sut2-c10/p1 - s67-t37-tg1-c10/p2.
1934 - testbed38:
1935     - ring1 25GE-ports xxv710-DA2-2p25GE:
1936         - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
1937         - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
1938         - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
1939     - ring2 25GE-ports e810-XXVDA4-4p25GE:
1940         - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
1941         - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
1942         - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
1943         - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
1944         - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
1945         - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
1946     - ring3 100GE-ports e810-2CQDA2-2p100GE:
1947         - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
1948         - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
1949         - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
1950     - ring4 200GE-ports ConnectX6-2p200GE:
1951         - s80-t38-tg1-c10/p1 to s78-t38-sut1-c10/p1.
1952         - s78-t38-sut1-c10/p2 to s79-t38-sut2-c10/p2.
1953         - s79-t38-sut2-c10/p1 to s80-t38-tg1-c10/p2.
1954 ```
1955
1956 ### 3-Node-SnowRidge (3n-snr)
1957
1958 ```
1959 - testbed39:
1960     - ring1 25GE-ports e810-XXVDA4-4p25GE:
1961         - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
1962         - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
1963         - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
1964         - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
1965         - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
1966         - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
1967 ```
1968
1969 ### 2-Node-SapphireRapids (2n-spr)
1970
1971 ```
1972 - testbed21:
1973     - ring1 200GE-ports ConnectX7-2p200GE:
1974         - s53-t21-tg1-c2/p1 to s52-t21-sut1-c2/p1
1975         - s53-t21-tg1-c7/p1 to s52-t21-sut1-c7/p1
1976         - s52-t21-sut1-c4/p2 to s52-t21-sut1-c9/p2
1977     - ring2 200GE-ports ConnectX7-2p200GE:
1978         - s53-t21-tg1-c2/p2 to s52-t21-sut1-c2/p2
1979         - s53-t21-tg1-c7/p2 to s52-t21-sut1-c7/p2
1980         - s52-t21-sut1-c10/p1 to s52-t21-sut1-c11/p1
1981     - ring3 200GE-ports ConnectX7-2p200GE:
1982         - s53-t21-tg1-c4/p1 to s52-t21-sut1-c4/p1
1983         - s53-t21-tg1-c9/p1 to s52-t21-sut1-c9/p1
1984         - s52-t21-sut1-c10/p2 to s52-t21-sut1-c11/p2
1985 - testbed22:
1986     - ring1 100GE-ports e810-2CQDA2-2p100GE:
1987         - s55-t22-tg1-c4/p1  to s54-t22-sut1-c9/p2
1988         - s55-t22-tg1-c4/p2  to s54-t22-sut1-c4/p2
1989         - s54-t22-sut1-c9/p1 to s54-t22-sut1-c4/p1
1990     - ring2 25GE-ports e810-XXVDA4-4p25GE:
1991         - s55-t22-tg1-c2/p1  to s54-t22-sut1-c2/p1
1992         - s55-t22-tg1-c2/p2  to s54-t22-sut1-c7/p1
1993         - s54-t22-sut1-c2/p2 to s54-t22-sut1-c7/p2
1994 - testbed23:
1995     - ring1 200GE-ports ConnectX7-2p200GE:
1996         - s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1.
1997         - s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2.
1998     - ring2 100GE-ports e810-2CQDA2-2p100GE:
1999         - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1.
2000         - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2.
2001     - ring3 25GE-ports e810-XXVDA4-2p25GE:
2002         - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1.
2003         - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2.
2004         - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3.
2005         - s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4.
2006     - ring4 200GE-ports ConnectX7-2p200GE:
2007         - s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2.
2008     - ring5 100GE-ports e810-2CQDA2-2p100GE:
2009         - s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2.
2010 - testbed24:
2011     - ring1 200GE-ports ConnectX7-2p200GE:
2012         - s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1.
2013         - s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2.
2014     - ring2 100GE-ports e810-2CQDA2-2p100GE:
2015         - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1.
2016         - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2.
2017     - ring3 25GE-ports e810-XXVDA4-2p25GE:
2018         - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1.
2019         - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2.
2020         - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3.
2021         - s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4.
2022     - ring4 200GE-ports ConnectX7-2p200GE:
2023         - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2.
2024     - ring5 100GE-ports e810-2CQDA2-2p100GE: