3 title: "FD.io DC Testbed Specifications"
7 # FD.io DC Testbed Specifications
11 This note includes specification of the physical testbed infrastructure
12 hosted by LFN FD.io CSIT project.
18 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
19 Management port, which are connected to two different VLANs.
22 - Subnet: 10.30.50.0/24
24 - Broadcast: 10.30.50.255
29 - Subnet: 10.30.51.0/24
31 - Broadcast: 10.30.51.255
35 To access these hosts, VPN connection is required.
42 #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr #spr #icxd
43 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0 0 0
44 2. 1-Node-Cascadelake nomad clx na 4 4 0 0 0 0 0 0 0 4 0 0 0 0 0
45 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0 0 0
46 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0 0 0
47 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0 0 0
48 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0 0 0
49 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0 0 0
50 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0 0 0
51 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0 0 0
52 10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0 0 0
53 11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0 0 0
54 12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0 0 0
55 13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2 0 0
56 14. 2-Node-SapphireRapids perf spr spr 4 4 4 0 0 0 0 0 0 0 0 0 0 8 0
57 15. 1-Node-SapphireRapids nomad spr na 4 4 0 0 0 0 0 0 0 0 0 0 0 4 0
58 16. 3-Node-IcelakeD perf icxd icx 2 4 1 0 0 0 0 0 0 0 0 1 0 0 4
59 Totals: 37 46 19.5 7 1 2 1 2 4 10 2 16.5 2 12 4
62 ### 1-Node-Skylake Xeon Intel (1n-skx)
64 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B2) with NIC
65 ports connected back-to-back ([Server Types](#server-types)).
66 Used for FD.io VPP_Device functional driver tests.
68 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
70 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
71 ports connected back-to-back ([Server Types](#server-types)).
72 Used for FD.io VPP_Device functional driver tests.
74 ### 1-Node-Skylake Xeon Intel (1n-spr)
76 Each 1-Node-SapphireRapids testbed includes one SUT (Server-Type-H7) with NIC
77 ports connected back-to-back ([Server Types](#server-types)).
78 Used for FD.io VPP_Device functional driver tests.
80 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
82 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
83 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
84 circular topology ([Server Types](#server-types)).
85 Used for FD.io TCP/IP and HTTP performance tests.
87 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
89 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
90 one TG (Server-Type-C3) connected in a 2-node circular topology
91 ([Server Types](#server-types)).
92 Used for FD.io performance tests.
94 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
96 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
97 one TG (Server-Type-D2) connected in a 2-node circular topology
98 ([Server Types](#server-types)).
99 Used for FD.io performance tests.
101 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
103 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
104 one TG (Server-Type-E31) connected in a 2-node circular topology
105 ([Server Types](#server-types)).
106 Used for FD.io performance tests.
108 ### 2-Node-Icelake Xeon Intel (2n-icx)
110 Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
111 one TG (Server-Type-F2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
115 ### 3-Node-Rangeley Atom Testbeds
117 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
118 TG (Server-Type-2) connected in a 3-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
122 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
124 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
125 TG (Server-Type-E31) connected in a 3-node circular topology
126 ([Server Types](#server-types)).
127 Used for FD.io performance tests.
129 ### 3-Node-Altra Arm Ampere (3n-alt)
131 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
132 TG (Server-Type-E32) connected in a 3-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
136 ### 3-Node-Icelake Xeon Intel (3n-icx)
138 Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F3) and one
139 TG (Server-Type-F3) connected in a 3-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
143 ### 3-Node-IcelakeD Xeon Intel (3n-icxd)
145 Each 3-Node-IcelakeD testbed includes two SUTs (Server-Type-I1) and one numa of
146 TG (Server-Type-F5) connected in a 3-node circular topology
147 ([Server Types](#server-types)).
148 Used for FD.io performance tests.
150 ### 3-Node-SnowRidge Atom Intel (3n-snr)
152 Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
153 TG (Server-Type-F5) connected in a 3-node circular topology
154 ([Server Types](#server-types)).
155 Used for FD.io performance tests.
157 ### 2-Node-SapphireRapids Xeon Intel (2n-spr)
159 Each 2-Node-SapphireRapids testbed includes one SUT (Server-Type-H5) and
160 one TG (Server-Type-H6) connected in a 2-node or 3-node circular topology
161 ([Server Types](#server-types)).
162 Used for FD.io performance tests.
165 ## Tesdtbed Naming Convention
167 Following naming convention is used within this page to specify physical
168 connectivity and wiring across defined CSIT testbeds:
170 - **testbedname**: testbedN.
172 - traffic-generator: tN-tgW.
173 - system-under-testX: tN-sutX.
178 - N - testbed number.
179 - tgW - server acts as traffic-generator with W index.
180 - sutX - server acts as system-under-test with X index.
181 - Y - PCIe slot number denoting a NIC card number within the host.
182 - Z - port number on the NIC card.
186 FD.io CSIT lab contains following server types:
188 1. **Server-Type-B1**: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
190 - Physical connectivity:
191 - IPMI and host management ports.
192 - Main HW configuration:
193 - Chassis: SuperMicro SYS-7049GP-TRT.
194 - Motherboard: SuperMicro X11DPG-QT.
195 - Processors: 2* Intel Platinum 8180 2.5 GHz.
196 - RAM Memory: 16* 16GB DDR4-2666MHz.
197 - Disks: 2* 1.6TB 6G SATA SSD.
198 - NICs configuration:
199 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
200 - PCIe Slot2 18:00.xx: empty.
201 - PCIe Slot4 3b:00.xx: empty.
202 - PCIe Slot9 5e:00.xx: empty.
203 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
204 - PCIe Slot6 86:00.xx: empty.
205 - PCIe Slot8 af:00.xx: empty.
206 - PCIe Slot10 d8:00.xx: empty.
208 2. **Server-Type-B2**: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
210 - Physical connectivity:
211 - IPMI and host management ports.
212 - NIC ports connected into 1-node topologies.
213 - Main HW configuration:
214 - Chassis: SuperMicro SYS-7049GP-TRT.
215 - Motherboard: SuperMicro X11DPG-QT.
216 - Processors: 2* Intel Platinum 8180 2.5 GHz.
217 - RAM Memory: 16* 16GB DDR4-2666MHz.
218 - Disks: 2* 1.6TB 6G SATA SSD.
219 - NICs configuration:
220 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
221 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
222 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
223 - PCIe Slot9 5e:00.xx: empty.
224 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
225 - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
226 - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
227 - PCIe Slot10 d8:00.xx: empty.
229 3. **Server-Type-B7**: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
231 - Physical connectivity:
232 - Host management interface: 10/100/1000-BaseT.
233 - 8-port 10GE SFP+ integrated NIC.
234 - Main HW configuration:
235 - Chassis: PS10GE4NG.
236 - Motherboard: SuperMicro X11DPG-QT.
237 - Processors: Quad-Core, Intel Processor.
238 - HW accelerators: FPGA offload.
240 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
241 - Physical Interfaces: 4 * 10GE SFP+.
242 - Operating System: Native IxOS.
243 - Interface configuration:
249 4. **Server-Type-B8**: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
251 - Physical connectivity:
252 - IPMI and host management ports.
254 - Main HW configuration:
255 - Chassis: SuperMicro SYS-7049GP-TRT.
256 - Motherboard: SuperMicro X11DPG-QT.
257 - Processors: 2* Intel Platinum 8180 2.5 GHz.
258 - RAM Memory: 16* 16GB DDR4-2666MHz.
259 - Disks: 2* 1.6TB 6G SATA SSD.
260 - NICs configuration:
261 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
262 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
263 - PCIe Slot4 3b:00.xx: empty.
264 - PCIe Slot9 5e:00.xx: empty.
265 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
266 - PCIe Slot6 86:00.xx: empty.
267 - PCIe Slot8 af:00.xx: empty.
268 - PCIe Slot10 d8:00.xx: empty.
270 5. **Server-Type-C2**: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
272 - Physical connectivity:
273 - IPMI and host management ports.
274 - NIC ports connected into 2-node testbed topologies.
275 - Main HW configuration:
276 - Chassis: SuperMicro SYS-7049GP-TRT.
277 - Motherboard: SuperMicro X11DPG-QT.
278 - Processors: 2* Intel Gold 6252N 2.3 GHz.
279 - RAM Memory: 12* 16GB DDR4-2933.
280 - Disks: 2* 1.92TB SATA SSD.
281 - NICs configuration:
282 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
283 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
284 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
285 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
286 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
287 - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
288 - PCIe Slot8 af:00.xx: empty.
289 - PCIe Slot10 d8:00.xx: empty.
291 6. **Server-Type-C3**: Purpose - Cascadelake Xeon TG for FD.io performance testing.
293 - Physical connectivity:
294 - IPMI and host management ports.
295 - NIC ports connected into 2-node testbed topologies.
296 - Main HW configuration:
297 - Chassis: SuperMicro SYS-7049GP-TRT.
298 - Motherboard: SuperMicro X11DPG-QT.
299 - Processors: 2* Intel Platinum 8280 2.7 GHz.
300 - RAM Memory: 12* 16GB DDR4-2933.
301 - Disks: 2* 1.92TB SATA SSD.
302 - NICs configuration:
303 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
304 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
305 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
306 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
307 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
308 - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
309 - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
310 - PCIe Slot10 d8:00.xx: empty.
312 7. **Server-Type-C4**: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
314 - Physical connectivity:
315 - IPMI and host management ports.
316 - no NIC ports, standalone setup.
317 - Main HW configuration:
318 - Chassis: SuperMicro 1029P-WTRT.
319 - Motherboard: SuperMicro X11DDW-NT.
320 - Processors: 2* Intel Platinum 8280 2.7 GHz.
321 - RAM Memory: 12* 16GB DDR4-2933.
322 - Disks: 4* 1.92TB SATA SSD.
323 - NICs configuration:
324 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
325 - PCIe Slot2 18:00.xx: empty.
326 - PCIe Slot4 3b:00.xx: empty.
327 - PCIe Slot9 5e:00.xx: empty.
328 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
329 - PCIe Slot6 86:00.xx: empty.
330 - PCIe Slot8 af:00.xx: empty.
331 - PCIe Slot10 d8:00.xx: empty.
333 8. **Server-Type-D1**: Purpose - Zen2 EPYC SUT for FD.io performance testing.
335 - Physical connectivity:
336 - IPMI and host management ports.
337 - NIC ports connected into 2-node testbed topologies.
338 - Main HW configuration:
339 - Chassis: SuperMicro AS-1114S-WTRT
340 - Processors: 1* AMD EPYC 7532 2.4 GHz.
341 - RAM Memory: 8* 32GB DDR4-2933.
342 - Disks: 1* 1TB SATA SSD.
343 - NICs configuration:
344 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
345 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
346 - PCIe Slot2 41:00.xx: xxv710-da2-2p25GE Intel.
347 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
349 9. **Server-Type-D2**: Purpose - Zen2 EPYC TG for FD.io performance testing.
351 - Physical connectivity:
352 - IPMI and host management ports.
353 - NIC ports connected into 2-node testbed topologies.
354 - Main HW configuration:
355 - Chassis: SuperMicro AS-1114S-WTRT
356 - Processors: 1* AMD EPYC 7532 2.4 GHz.
357 - RAM Memory: 8* 32GB DDR4-2933.
358 - Disks: 1* 1TB SATA SSD.
359 - NICs configuration:
360 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
361 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
362 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
363 - PCIe Slot3 81:00.xx: xxv710-da2 2p25GE Intel.
365 10. **Server-Type-E11**: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
367 - Physical connectivity:
368 - IPMI and host management ports.
369 - NIC ports connected into 1-node topologies.
370 - Main HW configuration:
371 - Chassis: GIGABYTE Rack Mount
372 - Motherboard: MT91-FS4-00
373 - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
374 - RAM Memory: 16 * 16GB DIMM
375 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
376 - NICs configuration:
378 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
379 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
381 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
382 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
384 11. **Server-Type-E21**: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
386 - Physical connectivity:
387 - IPMI(?) and host management ports.
388 - NIC ports connected into 3-node topology.
389 - Main HW configuration:
390 - Chassis: Huawei TaiShan 2280.
391 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
392 - RAM Memory: 8* 16GB DDR4-2400MT/s
393 - Disks: 1* 4TB SATA HDD
394 - NICs configuration:
395 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
396 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
398 12. **Server-Type-E22**: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
400 - Physical connectivity:
401 - IPMI and host management ports.
402 - NIC ports connected into 2-node topologies.
403 - Main HW configuration:
404 - Chassis: Gigabyte R181-T90 1U
405 - Motherboard: MT91-FS1
406 - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
407 - RAM Memory: 4* 32GB RDIMM
408 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
409 - NICs configuration:
413 - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
415 13. **Server-Type-E23**: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
417 - Physical connectivity:
418 - IPMI and host management ports.
419 - NIC ports connected into 3-node topologies.
420 - Main HW configuration:
421 - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
422 - Motherboard: Mt.Jade Motherboard
423 - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
424 - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
425 - RAM Memory: 16* 8GB DDR4-3200MT/s
426 - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
427 - NICs configuration:
428 - Numa0: (x16, x16 PCIe4.0 lanes)
429 - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
430 - PCIe Slot8 0001:00:00.x: ConnectX6-2p100GE Mellanox.
434 14. **Server-Type-E24**: Purpose - Altra Arm Ampere for FD.io build.
436 - Physical connectivity:
437 - IPMI and host management ports.
438 - Main HW configuration:
439 - Chassis: Gigabyte R152-P30-00 1U
440 - Motherboard: MP32-AR1-00
441 - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
442 - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
443 - RAM Memory: 12* 16GB DDR4-3200MT/s
444 - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
446 15. **Server-Type-E31**: Purpose - Skylake Xeon Shared TG for FD.io performance testing.
448 - Physical connectivity:
449 - IPMI and host management ports.
450 - NIC ports connected into 2-node and 3-node topologies.
451 - Main HW configuration:
452 - Chassis: SuperMicro SYS-7049GP-TRT.
453 - Motherboard: SuperMicro X11DPG-QT.
454 - Processors: 2* Intel Platinum 8180 2.5 GHz.
455 - RAM Memory: 16* 16GB DDR4-2666MHz.
456 - Disks: 2* 1.6TB 6G SATA SSD.
457 - NICs configuration:
458 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
459 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
460 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
461 - PCIe Slot9 5e:00.xx: empty.
462 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
463 - PCIe Slot6 86:00.xx: empty.
464 - PCIe Slot8 af:00.xx: xl710-QDA2-2p40GE Intel.
465 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
467 16. **Server-Type-E32**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
469 - Physical connectivity:
470 - IPMI and host management ports.
471 - NIC ports connected into 2-node and/or 3-node testbed topologies.
472 - Main HW configuration:
473 - Chassis: SuperMicro SYS-740GP-TNRT.
474 - Motherboard: Super X12DPG-QT6.
475 - Processors: 2* Intel Platinum 8358 2.6 GHz.
476 - RAM Memory: 16* 16GB DDR4-3200.
477 - Disks: 2* 960GB SATA SSD.
478 - NICs configuration:
479 - Numa0: (x16, x16, x16 PCIe4.0 lanes)
480 - PCIe Slot2 4b:00.xx: xxv710-DA2-2p25GE Intel.
481 - PCIe Slot4 31:00.xx: xl710-QDA2-2p40GE Intel.
482 - PCIe Slot9 ff:00.xx: empty.
483 - Numa1: (x16, x16, x16 PCIe4.0 lanes)
484 - PCIe Slot6 ca:00.xx: empty.
485 - PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
486 - PCIe Slot10 ff:00.xx: empty.
488 17. **Server-Type-F1**: Purpose - Icelake Xeon SUT for FD.io performance testing.
490 - Physical connectivity:
491 - IPMI and host management ports.
492 - NIC ports connected into 2-node topology.
493 - Main HW configuration:
494 - Chassis: SuperMicro SYS-740GP-TNRT.
495 - Motherboard: Super X12DPG-QT6.
496 - Processors: 2* Intel Platinum 8358 2.6 GHz.
497 - RAM Memory: 16* 16GB DDR4-3200.
498 - Disks: 2* 960GB SATA SSD.
499 - NICs configuration:
500 - Numa0: (x16, x16, x16 PCIe4.0 lanes)
501 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
502 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
503 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
504 - Numa1: (x16, x16, x16 PCIe4.0 lanes)
505 - PCIe Slot6 86:00.xx: empty.
506 - PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox.
507 - PCIe Slot10 d8:00.xx: empty.
509 18. **Server-Type-F2**: Purpose - Icelake Xeon TG for FD.io performance testing.
511 - Physical connectivity:
512 - IPMI and host management ports.
513 - NIC ports connected into 2-node testbed topologies.
514 - Main HW configuration:
515 - Chassis: SuperMicro SYS-740GP-TNRT.
516 - Motherboard: Super X12DPG-QT6.
517 - Processors: 2* Intel Platinum 8358 2.6 GHz.
518 - RAM Memory: 16* 16GB DDR4-3200.
519 - Disks: 2* 960GB SATA SSD.
520 - NICs configuration:
521 - Numa0: (x16, x16, x16 PCIe4.0 lanes)
522 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
523 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
524 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
525 - Numa1: (x16, x16, x16 PCIe4.0 lanes)
526 - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
527 - PCIe Slot8 af:00.xx: ConnectX7-2p200GE Mellanox.
528 - PCIe Slot10 d8:00.xx: empty.
530 19. **Server-Type-F3**: Purpose - Icelake Xeon TG or SUT for FD.io performance testing.
532 - Physical connectivity:
533 - IPMI and host management ports.
534 - NIC ports connected into 3-node testbed topologies.
535 - Main HW configuration:
536 - Chassis: SuperMicro SYS-740GP-TNRT.
537 - Motherboard: Super X12DPG-QT6.
538 - Processors: 2* Intel Platinum 8358 2.6 GHz.
539 - RAM Memory: 16* 16GB DDR4-3200.
540 - Disks: 2* 960GB SATA SSD.
541 - NICs configuration:
542 - Numa0: (x16, x16, x16 PCIe4.0 lanes)
543 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
544 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
545 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
546 - Numa1: (x16, x16, x16 PCIe4.0 lanes)
547 - PCIe Slot6 86:00.xx: ConnectX6-2p100GE Mellanox.
548 - PCIe Slot8 af:00.xx: empty.
549 - PCIe Slot10 d8:00.xx: empty.
551 20. **Server-Type-F4**: Purpose - Icelake Xeon TG for FD.io performance testing.
553 - Physical connectivity:
554 - IPMI and host management ports.
555 - NIC ports connected into 3-node testbed topologies.
556 - Main HW configuration:
557 - Chassis: SuperMicro SYS-740GP-TNRT.
558 - Motherboard: Super X12DPG-QT6.
559 - Processors: 2* Intel Platinum 8358 2.6 GHz.
560 - RAM Memory: 16* 16GB DDR4-3200.
561 - Disks: 2* 960GB SATA SSD.
562 - NICs configuration:
563 - Numa0: (x16, x16, x16 PCIe4.0 lanes)
564 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
565 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
566 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
567 - Numa1: (x16, x16, x16 PCIe4.0 lanes)
568 - PCIe Slot6 86:00.xx: ConnectX6-2p100GE Mellanox.
569 - PCIe Slot8 af:00.xx: empty.
570 - PCIe Slot10 d8:00.xx: empty.
572 21. **Server-Type-F5**: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
574 - Physical connectivity:
575 - IPMI and host management ports.
576 - NIC ports connected into 2-node and/or 3-node testbed topologies.
577 - Main HW configuration:
578 - Chassis: SuperMicro SYS-740GP-TNRT.
579 - Motherboard: Super X12DPG-QT6.
580 - Processors: 2* Intel Platinum 8358 2.6 GHz.
581 - RAM Memory: 16* 16GB DDR4-3200.
582 - Disks: 2* 960GB SATA SSD.
583 - NICs configuration:
584 - Numa0: (x16, x16, x16 PCIe4.0 lanes)
585 - PCIe Slot2 4b:00.xx: xxv710-DA2-2p25GE Intel.
586 - PCIe Slot4 31:00.xx: empty.
587 - PCIe Slot9 ff:00.xx: empty.
588 - Numa1: (x16, x16, x16 PCIe4.0 lanes)
589 - PCIe Slot6 ca:00.xx: e810-XXVDA4-4p25GE Intel.
590 - PCIe Slot8 b1:00.xx: e810-2CQDA2-2p100GE Intel.
591 - PCIe Slot10 ff:00.xx: empty.
593 22. **Server-Type-G1**: Purpose - SnowRidge Atom SUT for FD.io performance testing.
595 - Physical connectivity:
596 - IPMI and host management ports.
597 - NIC ports connected into 3-node testbed topology.
598 - Main HW configuration:
599 - Chassis: Intel JACOBSVILLE SDP.
600 - Motherboard: Intel JACOBSVILLE E63448-400.
601 - Processors: 1* Intel Atom P5362B 2.2 GHz.
602 - RAM Memory: 2* 16GB DDR4-2933.
603 - Disks: ?* ? SATA SSD.
604 - NICs configuration:
605 - Numa0: (x16, PCIe3.0 lane)
606 - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
608 23. **Server-Type-H1**: Purpose - SapphireRapids Xeon SUT for FD.io full system performance testing.
610 - Physical connectivity:
611 - IPMI and host management ports.
612 - NIC ports connected into 3-numa-node testbed topologies.
613 - Main HW configuration:
614 - Chassis: SuperMicro SYS-741GE-TNRT.
615 - Motherboard: Super X13DEG-QT-P.
616 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
617 - RAM Memory: 16* 32GB DDR5-4800.
618 - Disks: 2* 960GB SATA SSD.
619 - NICs configuration:
620 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
621 - PCIe Slot2 18:00.xx: ConnectX7-2p200GE Nvidia.
622 - PCIe Slot4 3b:00.xx: ConnectX7-2p200GE Nvidia.
623 - PCIe Slot10 5e:00.xx: ConnectX7-2p200GE Nvidia.
624 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
625 - PCIe Slot7 86:00.xx: ConnectX7-2p200GE Nvidia.
626 - PCIe Slot9 af:00.xx: ConnectX7-2p200GE Nvidia.
627 - PCIe Slot11 d8:00.xx: ConnectX7-2p200GE Nvidia.
629 24. **Server-Type-H2**: Purpose - SapphireRapids Xeon TG for FD.io full system performance testing.
631 - Physical connectivity:
632 - IPMI and host management ports.
633 - NIC ports connected into 3-numa-node testbed topologies.
634 - Main HW configuration:
635 - Chassis: SuperMicro SYS-741GE-TNRT.
636 - Motherboard: Super X13DEG-QT-P.
637 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
638 - RAM Memory: 16* 32GB DDR5-4800.
639 - Disks: 2* 960GB SATA SSD.
640 - NICs configuration:
641 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
642 - PCIe Slot2 18:00.xx: ConnectX7-2p200GE Nvidia.
643 - PCIe Slot4 3b:00.xx: ConnectX7-2p200GE Nvidia.
644 - PCIe Slot10 5e:00.xx: ConnectX7-2p200GE Nvidia.
645 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
646 - PCIe Slot7 86:00.xx: ConnectX7-2p200GE Nvidia.
647 - PCIe Slot9 af:00.xx: ConnectX7-2p200GE Nvidia.
648 - PCIe Slot11 d8:00.xx: empty.
650 25. **Server-Type-H3**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
652 - Physical connectivity:
653 - IPMI and host management ports.
654 - NIC ports connected into 3-numa-node testbed topologies.
655 - Main HW configuration:
656 - Chassis: SuperMicro SYS-741GE-TNRT.
657 - Motherboard: Super X13DEG-QT-P.
658 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
659 - RAM Memory: 16* 32GB DDR5-4800.
660 - Disks: 2* 960GB SATA SSD.
661 - NICs configuration:
662 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
663 - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
664 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
665 - PCIe Slot10 5e:00.xx: empty.
666 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
667 - PCIe Slot7 86:00.xx: e810-2CQDA2-2p100GE Intel.
668 - PCIe Slot9 af:00.xx: e810-XXVDA4-4p25GE Intel.
669 - PCIe Slot11 d8:00.xx: empty.
671 26. **Server-Type-H4**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
673 - Physical connectivity:
674 - IPMI and host management ports.
675 - NIC ports connected into 3-numa-node testbed topologies.
676 - Main HW configuration:
677 - Chassis: SuperMicro SYS-741GE-TNRT.
678 - Motherboard: Super X13DEG-QT-P.
679 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
680 - RAM Memory: 16* 32GB DDR5-4800.
681 - Disks: 2* 960GB SATA SSD.
682 - NICs configuration:
683 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
684 - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
685 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
686 - PCIe Slot10 5e:00.xx: empty.
687 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
688 - PCIe Slot7 86:00.xx: empty.
689 - PCIe Slot9 af:00.xx: empty.
690 - PCIe Slot11 d8:00.xx: empty.
692 27. **Server-Type-H5**: Purpose - SapphireRapids Xeon SUT for FD.io performance testing.
694 - Physical connectivity:
695 - IPMI and host management ports.
696 - NIC ports connected into 2-node testbed topologies.
697 - Main HW configuration:
698 - Chassis: SuperMicro SYS-741GE-TNRT.
699 - Motherboard: Super X13DEG-QT-P.
700 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
701 - RAM Memory: 16* 32GB DDR5-4800.
702 - Disks: 2* 960GB SATA SSD.
703 - NICs configuration:
704 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
705 - PCIe Slot2 3d:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
706 - PCIe Slot4 2c:00.xx: e810-2CQDA2-2p100GE Intel.
707 - PCIe Slot10 17:00.xx: e810-XXVDA4-4p25GE Intel.
708 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
709 - PCIe Slot7 86:00.xx: empty.
710 - PCIe Slot9 af:00.xx: empty.
711 - PCIe Slot11 d8:00.xx: empty.
713 28. **Server-Type-H6**: Purpose - SapphireRapids Xeon TG for FD.io performance testing.
715 - Physical connectivity:
716 - IPMI and host management ports.
717 - NIC ports connected into 2-node testbed topologies plus loopbacks in Numa1 for TG self-test.
718 - Main HW configuration:
719 - Chassis: SuperMicro SYS-741GE-TNRT.
720 - Motherboard: Super X13DEG-QT-P.
721 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
722 - RAM Memory: 16* 32GB DDR5-4800.
723 - Disks: 2* 960GB SATA SSD.
724 - NICs configuration:
725 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
726 - PCIe Slot2 18:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
727 - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
728 - PCIe Slot10 5e:00.xx: e810-XXVDA4-4p25GE Intel.
729 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
730 - PCIe Slot7 86:00.xx: MCX713106AS-VEAT ConnectX7-2p200GE Nvidia.
731 - PCIe Slot9 af:00.xx: e810-2CQDA2-2p100GE Intel.
732 - PCIe Slot11 d8:00.xx: empty.
734 29. **Server-Type-H7**: Purpose - SapphireRapids SUT for FD.io VPP_Device functional tests.
736 - Physical connectivity:
737 - IPMI and host management ports.
738 - NIC ports connected into 1-node topologies.
739 - Main HW configuration:
740 - Chassis: SuperMicro SYS-741GE-TNRT.
741 - Motherboard: Super X13DEG-QT-P.
742 - Processors: 2* Intel Platinum 8462Y+ 32 core 2.8 GHz 300W TDP.
743 - RAM Memory: 16* 32GB DDR5-4800.
744 - Disks: 2* 960GB SATA SSD.
745 - NICs configuration:
746 - Numa0: (x16, x16, x16 PCIe5.0 lanes)
747 - PCIe Slot2 18:00.xx: e810-2CQDA2-2p100GE Intel.
748 - PCIe Slot4 3b:00.xx: e810-2CQDA2-2p100GE Intel.
749 - PCIe Slot10 5e:00.xx: empty.
750 - Numa1: (x16, x16, x16 PCIe5.0 lanes)
751 - PCIe Slot7 86:00.xx: empty.
752 - PCIe Slot9 af:00.xx: empty.
753 - PCIe Slot11 d8:00.xx: empty.
755 30. **Server-Type-I1**: Purpose - IcelakeD Xeon SUT for FD.io performance testing.
757 - Physical connectivity:
758 - IPMI and host management ports.
759 - NIC ports connected into 3-node testbed topology.
760 - Main HW configuration:
761 - Chassis: SuperMicro SYS-110D-20C-FRDN8TP.
762 - Motherboard: Super X12SDV-20C-SPT8F.
763 - Processors: 1* Intel Xeon D-2796NT.
764 - RAM Memory: 4* 32GB DDR4-3200 MEM-DR432MD-ER32.
765 - Disks: 1* 960GB SATA SSD HDS-25T0.
766 - NICs configuration:
767 - Numa0: (x16, PCIe4.0 lane)
768 - PCIe BuiltIn ??:00.xx: e810-XXVDA2-2p25GE Intel.
770 ## Testbeds Configuration
772 ### 1-Node-Skylake (1n-skx)
775 - SUT [Server-Type-B2]:
776 - testbedname: testbed11.
777 - hostname: s1-t11-sut1.
778 - IPMI IP: 10.30.50.47
779 - Host IP: 10.30.51.50
781 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
782 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
783 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
784 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
785 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
786 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
787 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
788 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
789 - s1-t11-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
790 - s1-t11-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
791 - s1-t11-sut1-c8/p1 - 100GE-port1 e810-2p100GE.
792 - s1-t11-sut1-c8/p2 - 100GE-port2 e810-2p100GE.
793 - SUT [Server-Type-B2]:
794 - testbedname: testbed12.
795 - hostname: s2-t12-sut1.
796 - IPMI IP: 10.30.50.48
797 - Host IP: 10.30.51.51
799 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
800 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
801 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
802 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
803 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
804 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
805 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
806 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
807 - s2-t12-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
808 - s2-t12-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
809 - s2-t12-sut1-c8/p1 - 100GE-port1 e810-2p100GE.
810 - s2-t12-sut1-c8/p2 - 100GE-port2 e810-2p100GE.
813 ### 1-Node-ThunderX2 (1n-tx2)
816 - SUT [Server-Type-E11]:
817 - testbedname: testbed13
818 - hostname: s55-t13-sut1
819 - IPMI IP: 10.30.50.70
820 - Host IP: 10.30.51.70
822 - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
823 - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
824 - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
825 - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
826 - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
827 - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
828 - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
829 - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
830 - SUT [Server-Type-E11]:
831 - testbedname: testbed14
832 - hostname: s56-t14-sut1
833 - IPMI IP: 10.30.50.71
834 - Host IP: 10.30.51.71
836 - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
837 - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
838 - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
839 - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
840 - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
841 - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
842 - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
843 - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
846 ### 1-Node-SapphireRapids (1n-spr)
849 - SUT [Server-Type-H7]:
850 - testbedname: testbed15.
851 - hostname: s30-t15-sut1.
852 - IPMI IP: 10.30.50.30
853 - Host IP: 10.30.51.31
855 - s30-t15-sut1-c1/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
856 - s30-t15-sut1-c1/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
857 - s30-t15-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
858 - s30-t15-sut1-c2/p2 - 100GE-port1 e810-2CQDA2-2p100GE.
859 - SUT [Server-Type-H7]:
860 - testbedname: testbed16.
861 - hostname: s31-t16-sut1.
862 - IPMI IP: 10.30.50.31
863 - Host IP: 10.30.51.31
865 - s31-t16-sut1-c1/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
866 - s31-t16-sut1-c1/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
867 - s31-t16-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
868 - s31-t16-sut1-c2/p2 - 100GE-port1 e810-2CQDA2-2p100GE.
871 ### 2-Node-IxiaPS1L47 (2n-ps1)
874 - SUT [Server-Type-B8]:
875 - testbedname: testbed25.
876 - hostname: s25-t25-sut1.
877 - IPMI IP: 10.30.50.58
878 - Host IP: 10.30.51.61
880 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
881 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
882 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
883 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
884 - TG [Server-Type-B7]:
885 - testbedname: testbed25.
886 - hostname: s26-t25-tg1.
887 - IPMI IP: 10.30.50.59
888 - Host IP: 10.30.51.62
890 - s26-t25-tg1-p1 - 10GE-port1.
891 - s26-t25-tg1-p2 - 10GE-port2.
892 - s26-t25-tg1-p3 - 10GE-port3.
893 - s26-t25-tg1-p4 - 10GE-port4.
896 ### 2-Node-Cascadelake (2n-clx)
898 {{< figure src="/cdocs/testbed-2n-clx.svg" >}}
901 - SUT [Server-Type-C2]:
902 - testbedname: testbed27.
903 - hostname: s33-t27-sut1.
904 - IPMI IP: 10.30.55.18
905 - Host IP: 10.32.8.18
907 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
908 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
909 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
910 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
911 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
912 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
913 - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
914 - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
915 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
916 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
917 - TG [Server-Type-C3]:
918 - testbedname: testbed27.
919 - hostname: s34-t27-tg1.
920 - IPMI IP: 10.30.55.19
921 - Host IP: 10.32.8.19
923 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
924 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
925 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
926 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
927 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
928 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
929 - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
930 - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
931 - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
932 - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
933 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
934 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
935 - SUT [Server-Type-C2]:
936 - testbedname: testbed28.
937 - hostname: s35-t28-sut1.
938 - IPMI IP: 10.30.55.20
939 - Host IP: 10.32.8.20
941 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
942 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
943 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
944 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
945 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
946 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
947 - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
948 - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
949 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
950 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
951 - TG [Server-Type-C3]:
952 - testbedname: testbed28.
953 - hostname: s36-t28-tg1.
954 - IPMI IP: 10.30.55.21
955 - Host IP: 10.32.8.21
957 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
958 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
959 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
960 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
961 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
962 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
963 - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
964 - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
965 - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
966 - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
967 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
968 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
969 - SUT [Server-Type-C2]:
970 - testbedname: testbed29.
971 - hostname: s37-t29-sut1.
972 - IPMI IP: 10.30.55.22
973 - Host IP: 10.32.8.22
975 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
976 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
977 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
978 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
979 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
980 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
981 - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
982 - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
983 - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
984 - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
985 - TG [Server-Type-C3]:
986 - testbedname: testbed29.
987 - hostname: s38-t29-tg1.
988 - IPMI IP: 10.30.55.23
989 - Host IP: 10.32.8.23
991 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
992 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
993 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
994 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
995 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
996 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
997 - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
998 - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
999 - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1000 - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1003 ### 2-Node-Zen2 (2n-zn2)
1005 {{< figure src="/cdocs/testbed-2n-zn2.svg" >}}
1008 - SUT [Server-Type-D1]:
1009 - testbedname: testbed210.
1010 - hostname: s60-t210-sut1.
1011 - IPMI IP: 10.30.55.24
1012 - Host IP: 10.32.8.24
1014 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1015 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1016 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1017 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1018 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1019 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1020 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1021 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1022 - TG [Server-Type-D2]:
1023 - testbedname: testbed210.
1024 - hostname: s61-t210-tg1.
1025 - IPMI IP: 10.30.55.25
1026 - Host IP: 10.32.8.25
1028 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1029 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1030 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1031 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1032 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1033 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1034 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1035 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1038 ### 2-Node-ThunderX2 (2x-tx2)
1040 {{< figure src="/cdocs/testbed-2n-tx2.svg" >}}
1043 - SUT [Server-Type-E22]:
1044 - testbedname: testbed211.
1045 - hostname: s27-t211-sut1.
1046 - IPMI IP: 10.30.50.69
1047 - Host IP: 10.30.51.69
1049 - s27-t211-sut1-c18/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1050 - s27-t211-sut1-c18/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1051 - TG [Server-Type-E31]:
1052 - testbedname: testbed33 and testbed211.
1053 - hostname: s19-t33t211-tg1.
1054 - IPMI IP: 10.30.50.46
1055 - Host IP: 10.30.51.49
1057 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1058 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1059 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1060 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1061 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1062 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1063 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1064 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1065 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1066 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1067 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1068 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1071 ### 2-Node-Icelake (2n-icx)
1073 {{< figure src="/cdocs/testbed-2n-icx.svg" >}}
1076 - SUT [Server-Type-F1]:
1077 - testbedname: testbed212.
1078 - hostname: s71-t212-sut1.
1079 - IPMI IP: 10.30.50.81
1080 - Host IP: 10.30.51.81
1082 - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1083 - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1084 - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1085 - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1086 - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1087 - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1088 - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1089 - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1090 - s71-t212-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1091 - s71-t212-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1092 - TG [Server-Type-F2]:
1093 - testbedname: testbed212.
1094 - hostname: s72-t212-tg1.
1095 - IPMI IP: 10.30.50.82
1096 - Host IP: 10.30.51.82
1098 - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1099 - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1100 - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1101 - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1102 - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1103 - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1104 - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1105 - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1106 - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1107 - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1108 - s72-t212-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1109 - s72-t212-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1110 - SUT [Server-Type-F1]:
1111 - testbedname: testbed213.
1112 - hostname: s83-t213-sut1.
1113 - IPMI IP: 10.30.50.83
1114 - Host IP: 10.30.51.83
1116 - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1117 - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1118 - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1119 - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1120 - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1121 - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1122 - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1123 - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1124 - s83-t213-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1125 - s83-t213-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1126 - TG [Server-Type-F2]:
1127 - testbedname: testbed213.
1128 - hostname: s84-t213-tg1.
1129 - IPMI IP: 10.30.50.84
1130 - Host IP: 10.30.51.84
1132 - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1133 - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1134 - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1135 - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1136 - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1137 - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1138 - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1139 - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1140 - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1141 - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1142 - s84-t213-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1143 - s84-t213-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1144 - SUT [Server-Type-F1]:
1145 - testbedname: testbed214.
1146 - hostname: s85-t214-sut1.
1147 - IPMI IP: 10.30.50.85
1148 - Host IP: 10.30.51.85
1150 - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1151 - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1152 - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1153 - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1154 - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1155 - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1156 - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1157 - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1158 - s85-t214-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1159 - s85-t214-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1160 - TG [Server-Type-F2]:
1161 - testbedname: testbed214.
1162 - hostname: s86-t214-tg1.
1163 - IPMI IP: 10.30.50.86
1164 - Host IP: 10.30.51.86
1166 - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1167 - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1168 - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1169 - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1170 - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1171 - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1172 - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1173 - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1174 - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1175 - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1176 - s86-t214-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1177 - s86-t214-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1178 - SUT [Server-Type-F1]:
1179 - testbedname: testbed215.
1180 - hostname: s87-t215-sut1.
1181 - IPMI IP: 10.30.50.87
1182 - Host IP: 10.30.51.87
1184 - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1185 - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1186 - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1187 - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1188 - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1189 - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1190 - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1191 - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1192 - s87-t215-sut1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1193 - s87-t215-sut1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1194 - TG [Server-Type-F2]:
1195 - testbedname: testbed215.
1196 - hostname: s88-t215-tg1.
1197 - IPMI IP: 10.30.50.88
1198 - Host IP: 10.30.51.88
1200 - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1201 - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1202 - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1203 - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1204 - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1205 - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1206 - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1207 - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1208 - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1209 - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1210 - s88-t215-tg1-c8/p1 - 200GE-port1 ConnectX7-2p200GE.
1211 - s88-t215-tg1-c8/p2 - 200GE-port2 ConnectX7-2p200GE.
1214 ### 3-Node-Taishan (3n-tsh)
1216 {{< figure src="/cdocs/testbed-3n-tsh.svg" >}}
1219 - SUT [Server-Type-E21]:
1220 - testbedname: testbed33.
1221 - hostname: s17-t33-sut1.
1222 - IPMI IP: 10.30.50.36
1223 - Host IP: 10.30.51.36
1225 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1226 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1227 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1228 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1229 - SUT [Server-Type-E21]:
1230 - testbedname: testbed33.
1231 - hostname: s18-t33-sut2.
1232 - IPMI IP: 10.30.50.37
1233 - Host IP: 10.30.51.37
1235 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1236 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1237 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1238 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1239 - TG [Server-Type-E31]:
1240 - testbedname: testbed33 and testbed211.
1241 - hostname: s19-t33t211-tg1.
1242 - IPMI IP: 10.30.50.46
1243 - Host IP: 10.30.51.49
1245 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1246 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1247 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1248 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1249 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1250 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1251 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1252 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1253 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1254 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1255 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1256 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1259 ### 3-Node-Altra (3n-alt)
1261 {{< figure src="/cdocs/testbed-3n-alt.svg" >}}
1264 - SUT [Server-Type-E23]:
1265 - testbedname: testbed34.
1266 - hostname: s62-t34-sut1.
1267 - IPMI IP: 10.30.50.72
1268 - Host IP: 10.30.51.72
1270 - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1271 - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1272 - s62-t34-sut1-c8/p1 - 100GE-port1 ConnectX6-2p100GE.
1273 - s62-t34-sut1-c8/p2 - 100GE-port2 ConnectX6-2p100GE.
1274 - SUT [Server-Type-E23]:
1275 - testbedname: testbed34.
1276 - hostname: s63-t34-sut2.
1277 - IPMI IP: 10.30.50.73
1278 - Host IP: 10.30.51.73
1280 - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1281 - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1282 - s63-t34-sut2-c8/p1 - 100GE-port1 ConnectX6-2p100GE.
1283 - s63-t34-sut2-c8/p2 - 100GE-port2 ConnectX6-2p100GE.
1284 - TG [Server-Type-E32]:
1285 - testbedname: testbed34.
1286 - hostname: s64-t34-tg1.
1287 - IPMI IP: 10.30.50.74
1288 - Host IP: 10.30.51.74
1290 - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1291 - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1292 - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1293 - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1294 - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1295 - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1298 ### 3-Node-Icelake (3n-icx)
1300 {{< figure src="/cdocs/testbed-3n-icx.svg" >}}
1303 - SUT1 [Server-Type-F3]:
1304 - testbedname: testbed37.
1305 - hostname: s65-t37-sut1.
1306 - IPMI IP: 10.30.50.75
1307 - Host IP: 10.30.51.75
1309 - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1310 - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1311 - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1312 - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1313 - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1314 - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1315 - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1316 - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1317 - s65-t37-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
1318 - s65-t37-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
1319 - SUT2 [Server-Type-F3]:
1320 - testbedname: testbed37.
1321 - hostname: s66-t37-sut2.
1322 - IPMI IP: 10.30.50.76
1323 - Host IP: 10.30.51.76
1325 - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1326 - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1327 - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1328 - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1329 - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1330 - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1331 - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1332 - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1333 - s65-t37-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
1334 - s65-t37-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
1335 - TG [Server-Type-F3]:
1336 - testbedname: testbed37.
1337 - hostname: s67-t37-tg1.
1338 - IPMI IP: 10.30.50.77
1339 - Host IP: 10.30.51.77
1341 - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1342 - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1343 - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1344 - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1345 - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1346 - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1347 - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1348 - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1349 - s67-t37-tg1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
1350 - s67-t37-tg1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
1351 - SUT1 [Server-Type-F3]:
1352 - testbedname: testbed38.
1353 - hostname: s78-t38-sut1.
1354 - IPMI IP: 10.30.50.78
1355 - Host IP: 10.30.51.78
1357 - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1358 - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1359 - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1360 - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1361 - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1362 - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1363 - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1364 - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1365 - s78-t38-sut1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
1366 - s78-t38-sut1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
1367 - SUT2 [Server-Type-F3]:
1368 - testbedname: testbed38.
1369 - hostname: s79-t38-sut2.
1370 - IPMI IP: 10.30.50.79
1371 - Host IP: 10.30.51.79
1373 - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1374 - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1375 - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1376 - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1377 - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1378 - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1379 - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1380 - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1381 - s79-t38-sut2-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
1382 - s79-t38-sut2-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
1383 - TG [Server-Type-F3]:
1384 - testbedname: testbed38.
1385 - hostname: s80-t38-tg1.
1386 - IPMI IP: 10.30.50.80
1387 - Host IP: 10.30.51.80
1389 - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1390 - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1391 - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1392 - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1393 - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1394 - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1395 - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1396 - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1397 - s80-t38-tg1-c10/p1 - 100GE-port1 ConnectX6-2p100GE.
1398 - s80-t38-tg1-c10/p2 - 100GE-port2 ConnectX6-2p100GE.
1401 ### 3-Node-SnowRidge (3n-snr)
1403 {{< figure src="/cdocs/testbed-3n-snr.svg" >}}
1406 - ServerG1 [Server-Type-G1]:
1407 - testbedname: testbed39.
1408 - hostname: s93-t39-sut1.
1409 - IPMI IP: 10.30.50.93
1410 - Host IP: 10.30.51.93
1412 - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1413 - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1414 - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
1415 - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
1416 - ServerG1 [Server-Type-G1]:
1417 - testbedname: testbed39.
1418 - hostname: s94-t39-sut2.
1419 - IPMI IP: 10.30.50.94
1420 - Host IP: 10.30.51.94
1422 - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1423 - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1424 - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1425 - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1426 - ServerF4 [Server-Type-F5]:
1427 - testbedname: testbed39.
1428 - hostname: s89-t39t310-tg1.
1429 - IPMI IP: 10.30.50.89
1430 - Host IP: 10.30.51.89
1432 - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1433 - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1434 - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1435 - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1438 ### 2-Node-SapphireRapids (2n-spr)
1440 {{< figure src="/cdocs/testbed-2n-spr.svg" >}}
1443 - SUT [Server-Type-H1]:
1444 - testbedname: testbed21.
1445 - hostname: s52-t21-sut1.
1446 - IPMI IP: 10.30.50.52
1447 - Host IP: 10.30.51.52
1449 - s52-t21-sut1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
1450 - s52-t21-sut1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
1451 - s52-t21-sut1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
1452 - s52-t21-sut1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
1453 - s52-t21-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1454 - s52-t21-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1455 - s52-t21-sut1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
1456 - s52-t21-sut1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
1457 - s52-t21-sut1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1458 - s52-t21-sut1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1459 - TG [Server-Type-H2]:
1460 - testbedname: testbed21.
1461 - hostname: s53-t21-tg1.
1462 - IPMI IP: 10.30.50.53
1463 - Host IP: 10.30.51.53
1465 - s53-t21-tg1-c10/p1 - 200GE-port1 ConnectX7-2p200GE.
1466 - s53-t21-tg1-c10/p2 - 200GE-port2 ConnectX7-2p200GE.
1467 - s53-t21-tg1-c4/p1 - 200GE-port1 ConnectX7-2p200GE.
1468 - s53-t21-tg1-c4/p2 - 200GE-port2 ConnectX7-2p200GE.
1469 - s53-t21-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1470 - s53-t21-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1471 - s53-t21-tg1-c9/p1 - 200GE-port1 ConnectX7-2p200GE.
1472 - s53-t21-tg1-c9/p2 - 200GE-port2 ConnectX7-2p200GE.
1473 - s53-t21-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1474 - s53-t21-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1475 - SUT [Server-Type-H3]:
1476 - testbedname: testbed22.
1477 - hostname: s54-t22-sut1.
1478 - IPMI IP: 10.30.50.54
1479 - Host IP: 10.30.51.54
1481 - s54-t22-sut1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1482 - s54-t22-sut1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1483 - s54-t22-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1484 - s54-t22-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1485 - s54-t22-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1486 - s54-t22-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1487 - s54-t22-sut1-c7/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1488 - s54-t22-sut1-c7/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1489 - s54-t22-sut1-c9/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1490 - s54-t22-sut1-c9/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1491 - s54-t22-sut1-c9/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1492 - s54-t22-sut1-c9/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1493 - TG [Server-Type-H4]:
1494 - testbedname: testbed22.
1495 - hostname: s55-t22-tg1.
1496 - IPMI IP: 10.30.50.55
1497 - Host IP: 10.30.51.55
1499 - s55-t22-tg1-c2/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1500 - s55-t22-tg1-c2/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1501 - s55-t22-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1502 - s55-t22-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1503 - s55-t22-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1504 - s55-t22-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1505 - SUT [Server-Type-H5]:
1506 - testbedname: testbed23.
1507 - hostname: s56-t23-sut1.
1508 - IPMI IP: 10.30.50.56
1509 - Host IP: 10.30.51.56
1511 - s56-t23-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1512 - s56-t23-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1513 - s56-t23-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1514 - s56-t23-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1515 - s56-t23-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1516 - s56-t23-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1517 - s56-t23-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1518 - s56-t23-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1519 - TG [Server-Type-H6]:
1520 - testbedname: testbed23.
1521 - hostname: s57-t23-tg1.
1522 - IPMI IP: 10.30.50.57
1523 - Host IP: 10.30.51.57
1525 - s57-t23-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1526 - s57-t23-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1527 - s57-t23-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1528 - s57-t23-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1529 - s57-t23-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1530 - s57-t23-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1531 - s57-t23-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1532 - s57-t23-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1533 - s57-t23-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1534 - s57-t23-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1535 - s57-t23-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1536 - s57-t23-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1537 - SUT [Server-Type-H5]:
1538 - testbedname: testbed24.
1539 - hostname: s58-t24-sut1.
1540 - IPMI IP: 10.30.50.58
1541 - Host IP: 10.30.51.58
1543 - s58-t24-sut1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1544 - s58-t24-sut1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1545 - s58-t24-sut1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1546 - s58-t24-sut1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1547 - s58-t24-sut1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1548 - s58-t24-sut1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1549 - s58-t24-sut1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1550 - s58-t24-sut1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1551 - TG [Server-Type-H6]:
1552 - testbedname: testbed24.
1553 - hostname: s59-t24-tg1.
1554 - IPMI IP: 10.30.50.59
1555 - Host IP: 10.30.51.59
1557 - s59-t24-tg1-c2/p1 - 200GE-port1 ConnectX7-2p200GE.
1558 - s59-t24-tg1-c2/p2 - 200GE-port2 ConnectX7-2p200GE.
1559 - s59-t24-tg1-c4/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1560 - s59-t24-tg1-c4/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1561 - s59-t24-tg1-c10/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1562 - s59-t24-tg1-c10/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1563 - s59-t24-tg1-c10/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1564 - s59-t24-tg1-c10/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1565 - s59-t24-tg1-c7/p1 - 200GE-port1 ConnectX7-2p200GE.
1566 - s59-t24-tg1-c7/p2 - 200GE-port2 ConnectX7-2p200GE.
1567 - s59-t24-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1568 - s59-t24-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1571 ### 3-Node-IcelakeD (3n-icxd)
1573 {{< figure src="/cdocs/testbed-3n-icxd.svg" >}}
1576 - ServerI1 [Server-Type-I1]:
1577 - testbedname: testbed31.
1578 - hostname: s32-t31-sut1.
1579 - IPMI IP: 10.30.50.32
1580 - Host IP: 10.30.51.32
1582 - s32-t31-sut1-c1/p1 - 25GE-port1 e822cq-2p25GE.
1583 - s32-t31-sut1-c1/p2 - 25GE-port2 e822cq-2p25GE.
1584 - ServerI1 [Server-Type-I1]:
1585 - testbedname: testbed31.
1586 - hostname: s33-t31-sut2.
1587 - IPMI IP: 10.30.50.33
1588 - Host IP: 10.30.51.33
1590 - s33-t31-sut2-c1/p1 - 25GE-port1 e822cq-2p25GE.
1591 - s33-t31-sut2-c1/p2 - 25GE-port2 e822cq-2p25GE.
1592 - ServerF3 [Server-Type-F5]:
1593 - testbedname: testbed31.
1594 - hostname: s90-t31t32-tg1.
1595 - IPMI IP: 10.30.50.90
1596 - Host IP: 10.30.51.90
1598 - s90-t31t32-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1599 - s90-t31t32-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1600 - s90-t31t32-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1601 - s90-t31t32-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1602 - ServerI1 [Server-Type-I1]:
1603 - testbedname: testbed32.
1604 - hostname: s34-t32-sut1.
1605 - IPMI IP: 10.30.50.34
1606 - Host IP: 10.30.51.34
1608 - s34-t32-sut1-c1/p1 - 25GE-port1 e822cq-2p25GE.
1609 - s34-t32-sut1-c1/p2 - 25GE-port2 e822cq-2p25GE.
1610 - ServerI1 [Server-Type-I1]:
1611 - testbedname: testbed32.
1612 - hostname: s35-t32-sut2.
1613 - IPMI IP: 10.30.50.35
1614 - Host IP: 10.30.51.35
1616 - s35-t32-sut2-c1/p1 - 25GE-port1 e822cq-2p25GE.
1617 - s35-t32-sut2-c1/p2 - 25GE-port2 e822cq-2p25GE.
1618 - ServerF3 [Server-Type-F5]:
1619 - testbedname: testbed32.
1620 - hostname: s90-t31t32-tg1.
1621 - IPMI IP: 10.30.50.90
1622 - Host IP: 10.30.51.90
1624 - s90-t31t32-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1625 - s90-t31t32-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1626 - s90-t31t32-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1627 - s90-t31t32-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1632 ### 1-Node-Skylake (1n-skx)
1636 - ring1 10GE-ports x710-4p10GE:
1637 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1638 - ring2 10GE-ports x710-4p10GE:
1639 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1640 - ring3 10GE-ports x710-4p10GE:
1641 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1642 - ring4 10GE-ports x710-4p10GE:
1643 - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1644 - ring5 100GE-ports e810-2p100GE:
1645 - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1646 - ring6 100GE-ports e810-2p100GE:
1647 - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1649 - ring1 10GE-ports x710-4p10GE:
1650 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1651 - ring2 10GE-ports x710-4p10GE:
1652 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1653 - ring3 10GE-ports x710-4p10GE:
1654 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1655 - ring4 10GE-ports x710-4p10GE:
1656 - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1657 - ring5 100GE-ports e810-2p100GE:
1658 - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1659 - ring6 100GE-ports e810-2p100GE:
1660 - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1663 ### 1-Node-ThunderX2 (1n-tx2)
1667 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1668 - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1669 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1670 - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1671 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1672 - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1673 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1674 - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1677 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1678 - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1679 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1680 - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1681 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1682 - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1683 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1684 - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1687 ### 1-Node-SapphireRapids (1n-spr)
1691 - ring1 100GE-ports e810-2p100GE:
1692 - s30-t15-sut1-c1/p1 to s30-t15-sut1-c2/p1.
1693 - ring2 100GE-ports e810-2p100GE:
1694 - s30-t15-sut1-c1/p2 to s30-t15-sut1-c2/p2.
1696 - ring1 100GE-ports e810-2p100GE:
1697 - s31-t16-sut1-c1/p1 to s31-t16-sut1-c2/p1.
1698 - ring2 100GE-ports e810-2p100GE:
1699 - s31-t16-sut1-c1/p2 to s31-t16-sut1-c2/p2.
1702 ### 2-Node-IxiaPS1L47 (2n-ps1)
1706 - link1 10GE-port x710-4p10GE on SUT:
1707 - t25-tg1-p1 to t25-sut1-c2/p1.
1708 - link2 10GE-port x710-4p10GE on SUT:
1709 - t25-tg1-p2 to t25-sut1-c2/p2.
1710 - link3 10GE-port x710-4p10GE on SUT:
1711 - t25-tg1-p3 to t25-sut1-c2/p3.
1712 - link4 10GE-port x710-4p10GE on SUT:
1713 - t25-tg1-p4 to t25-sut1-c2/p4.
1716 ### 2-Node-Cascadelake (2n-clx)
1720 - ring1 10GE-ports x710-4p10GE on SUT:
1721 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1722 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1723 - ring2 10GE-ports x710-4p10GE on SUT:
1724 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1725 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1726 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1727 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1728 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1729 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1730 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1731 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1732 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1733 - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1734 - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1735 - ring6 100GE-ports e810-2p100GE on TG:
1736 - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
1737 - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
1739 - ring1 10GE-ports x710-4p10GE on SUT:
1740 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1741 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1742 - ring2 10GE-ports x710-4p10GE on SUT:
1743 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1744 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1745 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1746 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1747 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1748 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1749 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1750 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1751 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1752 - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1753 - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1754 - ring6 100GE-ports e810-2p100GE on TG:
1755 - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
1756 - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
1758 - ring1 10GE-ports x710-4p10GE on SUT:
1759 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1760 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1761 - ring2 10GE-ports x710-4p10GE on SUT:
1762 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1763 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1764 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1765 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1766 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1767 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1768 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1769 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1770 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1771 - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1772 - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1775 ### 2-Node-Zen2 (2n-zn2)
1779 - ring1 10GE-ports x710-4p10GE on SUT:
1780 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1781 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1782 - ring2 10GE-ports x710-4p10GE on SUT:
1783 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1784 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1785 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1786 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1787 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1788 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1789 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1790 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1793 ### 2-Node-ThunderX2 (2n-tx2)
1797 - ring1 10GE-ports x520-2p10GE on SUTs:
1798 - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
1799 - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
1802 ### 2-Node-Icelake (2n-icx)
1806 - ring1 25GE-ports xxv710-DA2-2p25GE:
1807 - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
1808 - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
1809 - ring2 25GE-ports e810-XXVDA4-2p25GE:
1810 - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
1811 - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
1812 - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
1813 - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
1814 - ring3 100GE-ports e810-2CQDA2-2p100GE:
1815 - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
1816 - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
1817 - ring4 100GE-ports e810-2CQDA2-2p100GE:
1818 - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
1819 - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
1820 - ring5 200GE-ports ConnectX7-2p200GE:
1821 - s72-t212-tg1-c8/p1 to s71-t212-sut1-c8/p1.
1822 - s71-t212-sut1-c8/p2 to s72-t212-tg1-c8/p2.
1824 - ring1 25GE-ports xxv710-DA2-2p25GE:
1825 - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
1826 - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
1827 - ring2 25GE-ports e810-XXVDA4-2p25GE:
1828 - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
1829 - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
1830 - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
1831 - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
1832 - ring3 100GE-ports e810-2CQDA2-2p100GE:
1833 - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
1834 - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
1835 - ring4 100GE-ports e810-2CQDA2-2p100GE:
1836 - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
1837 - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
1838 - ring5 200GE-ports ConnectX7-2p200GE:
1839 - s84-t213-tg1-c8/p1 to s83-t213-sut1-c8/p1.
1840 - s83-t213-sut1-c8/p2 to s84-t213-tg1-c8/p2.
1842 - ring1 25GE-ports xxv710-DA2-2p25GE:
1843 - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
1844 - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
1845 - ring2 25GE-ports e810-XXVDA4-2p25GE:
1846 - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
1847 - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
1848 - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
1849 - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
1850 - ring3 100GE-ports e810-2CQDA2-2p100GE:
1851 - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
1852 - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
1853 - ring4 100GE-ports e810-2CQDA2-2p100GE:
1854 - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
1855 - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
1856 - ring5 200GE-ports ConnectX7-2p200GE:
1857 - s86-t214-tg1-c8/p1 to s85-t214-sut1-c8/p1.
1858 - s85-t214-sut1-c8/p2 to s86-t214-tg1-c8/p2.
1860 - ring1 25GE-ports xxv710-DA2-2p25GE:
1861 - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
1862 - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
1863 - ring2 25GE-ports e810-XXVDA4-2p25GE:
1864 - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
1865 - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
1866 - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
1867 - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
1868 - ring3 100GE-ports e810-2CQDA2-2p100GE:
1869 - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
1870 - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
1871 - ring4 100GE-ports e810-2CQDA2-2p100GE:
1872 - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
1873 - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
1874 - ring5 200GE-ports ConnectX7-2p200GE:
1875 - s88-t215-tg1-c8/p1 to s87-t215-sut1-c8/p1.
1876 - s87-t215-sut1-c8/p2 to s88-t215-tg1-c8/p2.
1879 ### 3-Node-Rangeley (3n-rng)
1885 ### 3-Node-Taishan (3n-tsh)
1889 - ring1 10GE-ports x520-2p10GE on SUTs:
1890 - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1891 - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1892 - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
1893 - ring2 25GE-ports cx4-2p25GE on SUTs:
1894 - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1895 - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1896 - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
1899 ### 3-Node-Altra (3n-alt)
1903 - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
1904 - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
1905 - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
1906 - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
1907 - ring2 100GE-ports ConnectX6-2p100GE Mellanox on SUTs:
1908 - s64-t34-tg1-c8/p1 - s62-t34-sut2-c8/p1.
1909 - s62-t34-sut1-c8/p1 - s63-t34-sut2-c8/p2.
1910 - s63-t34-sut1-c8/p2 - s64-t34-tg1-c8/p2.
1913 ### 3-Node-Icelake (3n-icx)
1917 - ring1 25GE-ports xxv710-DA2-2p25GE:
1918 - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
1919 - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
1920 - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
1921 - ring2 25GE-ports e810-XXVDA4-4p25GE:
1922 - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
1923 - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
1924 - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
1925 - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
1926 - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
1927 - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
1928 - ring3 100GE-ports e810-2CQDA2-2p100GE:
1929 - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
1930 - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
1931 - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
1932 - ring4 200GE-ports ConnectX6-2p200GE:
1933 - s67-t37-tg1-c10/p1 - s65-t37-sut1-c10/p2.
1934 - s65-t37-sut1-c10/p1 - s66-t37-sut2-c10/p2.
1935 - s66-t37-sut2-c10/p1 - s67-t37-tg1-c10/p2.
1937 - ring1 25GE-ports xxv710-DA2-2p25GE:
1938 - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
1939 - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
1940 - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
1941 - ring2 25GE-ports e810-XXVDA4-4p25GE:
1942 - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
1943 - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
1944 - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
1945 - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
1946 - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
1947 - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
1948 - ring3 100GE-ports e810-2CQDA2-2p100GE:
1949 - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
1950 - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
1951 - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
1952 - ring4 200GE-ports ConnectX6-2p200GE:
1953 - s80-t38-tg1-c10/p1 to s78-t38-sut1-c10/p1.
1954 - s78-t38-sut1-c10/p2 to s79-t38-sut2-c10/p2.
1955 - s79-t38-sut2-c10/p1 to s80-t38-tg1-c10/p2.
1958 ### 3-Node-SnowRidge (3n-snr)
1962 - ring1 25GE-ports e810-XXVDA4-4p25GE:
1963 - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
1964 - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
1965 - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
1966 - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
1967 - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
1968 - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
1971 ### 2-Node-SapphireRapids (2n-spr)
1975 - ring1 200GE-ports ConnectX7-2p200GE:
1976 - s53-t21-tg1-c2/p1 to s52-t21-sut1-c2/p1
1977 - s53-t21-tg1-c7/p1 to s52-t21-sut1-c7/p1
1978 - s52-t21-sut1-c4/p2 to s52-t21-sut1-c9/p2
1979 - ring2 200GE-ports ConnectX7-2p200GE:
1980 - s53-t21-tg1-c2/p2 to s52-t21-sut1-c2/p2
1981 - s53-t21-tg1-c7/p2 to s52-t21-sut1-c7/p2
1982 - s52-t21-sut1-c10/p1 to s52-t21-sut1-c11/p1
1983 - ring3 200GE-ports ConnectX7-2p200GE:
1984 - s53-t21-tg1-c4/p1 to s52-t21-sut1-c4/p1
1985 - s53-t21-tg1-c9/p1 to s52-t21-sut1-c9/p1
1986 - s52-t21-sut1-c10/p2 to s52-t21-sut1-c11/p2
1988 - ring1 100GE-ports e810-2CQDA2-2p100GE:
1989 - s55-t22-tg1-c4/p1 to s54-t22-sut1-c9/p2
1990 - s55-t22-tg1-c4/p2 to s54-t22-sut1-c4/p2
1991 - s54-t22-sut1-c9/p1 to s54-t22-sut1-c4/p1
1992 - ring2 25GE-ports e810-XXVDA4-4p25GE:
1993 - s55-t22-tg1-c2/p1 to s54-t22-sut1-c2/p1
1994 - s55-t22-tg1-c2/p2 to s54-t22-sut1-c7/p1
1995 - s54-t22-sut1-c2/p2 to s54-t22-sut1-c7/p2
1997 - ring1 200GE-ports ConnectX7-2p200GE:
1998 - s56-t23-sut1-c2/p1 to s57-t23-tg1-c2/p1.
1999 - s57-t23-tg1-c2/p2 to s56-t23-sut1-c2/p2.
2000 - ring2 100GE-ports e810-2CQDA2-2p100GE:
2001 - s56-t23-sut1-c4/p1 to s57-t23-tg1-c4/p1.
2002 - s57-t23-tg1-c4/p2 to s56-t23-sut1-c4/p2.
2003 - ring3 25GE-ports e810-XXVDA4-4p25GE:
2004 - s56-t23-sut1-c10/p1 to s57-t23-tg1-c10/p1.
2005 - s56-t23-sut1-c10/p2 to s57-t23-tg1-c10/p2.
2006 - s56-t23-sut1-c10/p3 to s57-t23-tg1-c10/p3.
2007 - s56-t23-sut1-c10/p4 to s57-t23-tg1-c10/p4.
2008 - ring4 200GE-ports ConnectX7-2p200GE:
2009 - s57-t23-tg1-c7/p1 to s57-t23-tg1-c7/p2.
2010 - ring5 100GE-ports e810-2CQDA2-2p100GE:
2011 - s57-t23-tg1-c9/p1 to s57-t23-tg1-c9/p2.
2013 - ring1 200GE-ports ConnectX7-2p200GE:
2014 - s58-t24-sut1-c2/p1 to s59-t24-tg1-c2/p1.
2015 - s59-t24-tg1-c2/p2 to s58-t24-sut1-c2/p2.
2016 - ring2 100GE-ports e810-2CQDA2-2p100GE:
2017 - s58-t24-sut1-c4/p1 to s59-t24-tg1-c4/p1.
2018 - s59-t24-tg1-c4/p2 to s58-t24-sut1-c4/p2.
2019 - ring3 25GE-ports e810-XXVDA4-4p25GE:
2020 - s58-t24-sut1-c10/p1 to s59-t24-tg1-c10/p1.
2021 - s58-t24-sut1-c10/p2 to s59-t24-tg1-c10/p2.
2022 - s58-t24-sut1-c10/p3 to s59-t24-tg1-c10/p3.
2023 - s58-t24-sut1-c10/p4 to s59-t24-tg1-c10/p4.
2024 - ring4 200GE-ports ConnectX7-2p200GE:
2025 - s59-t24-tg1-c7/p1 to s59-t24-tg1-c7/p2.
2026 - ring5 100GE-ports e810-2CQDA2-2p100GE:
2027 - s59-t24-tg1-c9/p1 to s59-t24-tg1-c9/p2.
2030 ### 3-Node-IcelakeD (3n-icxd)
2034 - ring1 25GE-ports e822cq-2p25GE:
2035 - s90-t31t32-tg1-c4/p1 to s32-t31-sut1-c1/p1.
2036 - s32-t31-sut1-c1/p2 to s33-t31-sut2-c1/p2.
2037 - s33-t31-sut2-c1/p1 to s90-t31t32-tg1-c4/p2.
2039 - ring1 25GE-ports e822cq-2p25GE:
2040 - s90-t31t32-tg1-c6/p1 to s34-t32-sut1-c1/p1.
2041 - s34-t32-sut1-c1/p2 to s35-t32-sut2-c1/p2.
2042 - s35-t32-sut2-c1/p1 to s90-t31t32-tg1-c6/p2.