FIX: Selecting VPP packages
[csit.git] / docs / lab / Testbeds_Xeon_Hsw_VIRL.md
1 ## FD.io CSIT Testbeds - Xeon Haswell
2
3 This is a low-level design implemented as an original FD.io CSIT lab based on
4 Cisco UCS-c240m4 servers based on Intel Xeon Haswell processors.
5
6 ### Server Hardware Configuration
7
8 Total of 10 Cisco UCS-c240 servers with Intel Xeon Haswell processors have been
9 used to built FD.io CSIT 3-Node Haswell (3n-hsw) performance testbeds and VIRL
10 functional testbeds. Following three HW configuration types of UCS x86 servers
11 are used:
12
13 ```
14  1. Type-1: Purpose - VPP functional and performance conformance testing.
15     - Quantity: 6 computers as SUT hosts (Systems Under Test).
16     - Physical connectivity:
17         - CIMC and host management ports.
18         - NIC ports connected in 3-node topologies.
19     - Main HW configuration:
20         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
21         - Processors: 2* E5-2699v3 2.3 GHz.
22         - RAM Memory: 16* 32GB DDR4-2133MHz.
23         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
24     - NICs configuration:
25         - Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
26             - PCIe Slot1: Cisco VIC 1385 2p40GE.
27             - PCIe Slot2: Intel NIC x520 2p10GE.
28             - PCIe Slot3: empty.
29         - Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
30             - PCIe Slot4: Intel NIC xl710 2p40GE.
31             - PCIe Slot5: Intel NIC x710 2p10GE.
32             - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
33         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
34  2. Type-2: Purpose - VPP functional and performance conformance testing.
35     - Quantity: 3 computers as TG hosts (Traffic Generators).
36     - Physical connectivity:
37         - CIMC and host management ports.
38         - NIC ports connected in 3-node topologies.
39     - Main HW configuration:
40         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
41         - Processors: 2* E5-2699v3 2.3 GHz.
42         - RAM Memory: 16* 32GB DDR4-2133MHz.
43         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
44     - NICs configuration:
45         - Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
46             - PCIe Slot1: Intel NIC xl710 2p40GE.
47             - PCIe Slot2: Intel NIC x710 2p10GE.
48             - PCIe Slot3: Intel NIC x710 2p10GE.
49         - Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
50             - PCIe Slot4: Intel NIC xl710 2p40GE.
51             - PCIe Slot5: Intel NIC x710 2p10GE.
52             - PCIe Slot6: Intel NIC x710 2p10GE.
53         - MLOM slot: empty.
54  3. Type-3: Purpose - VIRL functional conformance.
55     - Quantity: 3 computers as VIRL hosts.
56     - Physical connectivity:
57         - CIMC and host management ports.
58         - no NIC ports, standalone setup.
59     - Main HW configuration:
60         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
61         - Processors: 2* E5-2699v3 2.3 GHz.
62         - RAM Memory: 16* 32GB DDR4-2133MHz.
63         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
64     - NICs configuration:
65         - Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
66             - no cards.
67         - Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
68             - no cards.
69         - MLOM slot: empty.
70 ```
71
72 ## Testbeds1,2,3 Connectivity
73
74 ### Management Ports
75
76 Total of 10 UCSC-C240-M4SX servers is made available for FD.IO CSIT testbed. For
77 management purposes, each server must have following two ports connected to the
78 management network:
79
80 ```
81  1. 1GE CIMC port
82     - CIMC - Cisco Integrated Management Controller.
83     - Required for provides embedded server management with WebUI, CLI, SNMPv3,
84       IPMIv2.0.
85  2. 1GE management port
86     - hostOS management port.
87 ```
88
89 ### Naming Convention
90
91 Following naming convention is used within this page to specify physical
92 connectivity and wiring across defined CSIT testbeds:
93
94 ```
95  - testbedname: testbedN.
96  - hostname:
97     - traffic-generator: tN-tgW.
98     - system-under-testX: tN-sutX.
99  - portnames:
100     - tN-tgW-cY/pZ.
101     - tN-sutX-cY/pZ.
102  - where:
103     - N - testbed number.
104     - tgW - server acts as traffic-generator with W index.
105     - sutX - server acts as system-under-test with X index.
106     - Y - PCIe slot number denoting a NIC card number within the host.
107         - Y=1,2,3 - slots in Riser 1, Right PCIe Riser Board, NUMA node 0.
108         - Y=4,5,6 - slots in Riser 2, Left PCIe Riser Board, NUMA node 1.
109         - Y=m - the MLOM slot.
110     - Z - port number on the NIC card.
111 ```
112
113 ### 3-node Topology Testbeds for Performance
114
115 Nine servers are used to build three of 3-node topologies, with each topology
116 using two servers of Type-1 (SUT function) and one server of Type-2
117 (TG function). Server NIC cards are placed and NIC ports are connected using the
118 scheme defined in next sections.
119
120 ### LOM (CIMC) and Management networks
121
122 Each server has a LOM (Lights-Out-Management e.g. Cisco CIMC) and a Management
123 port, which are connected to two different VLANs.
124
125 ```
126  1. LOM (CIMC) VLAN:
127     - Subnet: 10.30.50.0/24
128     - Gateway: 10.30.50.1
129     - Broadcast: 10.30.50.255
130     - DNS1: 199.204.44.24
131     - DNS2: 199.204.47.54
132  2. Management Vlan:
133     - Subnet: 10.30.51.0/24
134     - Gateway: 10.30.51.1
135     - Broadcast: 10.30.51.255
136     - DNS1: 199.204.44.24
137     - DNS2: 199.204.47.54
138 ```
139 To access these hosts, an VPN connection is required.
140
141 #### LOM (CIMC) VLAN IP Addresses allocation
142
143 Name | Comment
144 ---- | -------
145 10.30.50.0 | network
146 10.30.51.1 | Router
147 10.30.50.2 | LF Reserved
148 10.30.50.3 | LF Reserved
149 10.30.50.4 | LF Reserved
150 10.30.50.5 | LF Reserved
151 10.30.50.6 | LF Reserved
152 10.30.50.7 | LF Reserved
153 10.30.50.8 | LF Reserved
154 10.30.50.9 | LF Reserved
155 10.30.50.10 | LF Reserved
156 10.30.50.11 | LF Reserved
157 10.30.50.12 | LF Reserved
158 10.30.50.13 | LF Reserved
159 10.30.50.14 | LF Reserved
160 10.30.50.15 | LF Reserved
161 10.30.50.16 | t1-tg1
162 10.30.50.17 | t1-sut1
163 10.30.50.18 | t1-sut2
164 10.30.50.20 | t2-tg1
165 10.30.50.21 | t2-sut1
166 10.30.50.22 | t2-sut2
167 10.30.50.24 | t3-tg1
168 10.30.50.25 | t3-sut1
169 10.30.50.26 | t3-sut-2
170 10.30.50.28 | t4-sut1
171 10.30.50.29 | t4-sut2
172 10.30.50.30 | t4-sut3
173 10.30.50.255 | Broadcast
174
175 #### Management VLAN IP Addresses allocation
176
177 Name | Comment
178 ---- | -------
179 10.30.51.0 | network
180 10.30.51.1 | Router
181 10.30.51.2 | LF Reserved
182 10.30.51.3 | LF Reserved
183 10.30.51.4 | LF Reserved
184 10.30.51.5 | LF Reserved
185 10.30.51.6 | LF Reserved
186 10.30.51.7 | LF Reserved
187 10.30.51.8 | LF Reserved
188 10.30.51.9 | netgate-1
189 10.30.51.10 | netgate-2
190 10.30.51.11 | netgate-3
191 10.30.51.12 | softiron-1
192 10.30.51.13 | softiron-2
193 10.30.51.14 | softiron-3
194 10.30.51.15 | LF Reserved
195 10.30.51.16 | t1-tg1
196 10.30.51.17 | t1-sut1
197 10.30.51.18 | t1-sut2
198 10.30.51.20 | t2-tg1
199 10.30.51.21 | t2-sut1
200 10.30.51.22 | t2-sut2
201 10.30.51.24 | t3-tg1
202 10.30.51.25 | t3-sut1
203 10.30.51.26 | t3-sut-2
204 10.30.51.28 | t4-sut1
205 10.30.51.29 | t4-sut2
206 10.30.51.30 | t4-sut3
207 10.30.51.31-10.30.51.105 | VIRL1
208 10.30.51.106-10.30.51.180 | VIRL2
209 10.30.51.181-10.30.51.254 | VIRL3
210 10.30.51.255 | Broadcast
211
212 ### Testbeds1,2,3 Naming: Servers, Ports
213
214 Each server in 3-node Topology has its NIC cards placed, and NIC cards and ports
215 indexed using defined naming convention:
216
217 ```
218  1. Server1 of Type-1:
219     - testbedname: testbed1.
220     - hostname: t1-sut1.
221     - CIMC IP: 10.30.50.17
222     - Host IP: 10.30.51.17
223     - portnames:
224         - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
225         - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
226         - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
227         - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
228         - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
229         - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
230         - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
231         - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
232         - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
233         - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
234  2. Server2 of Type-1:
235     - testbedname: testbed1.
236     - hostname: t1-sut2.
237     - CIMC IP: 10.30.50.18
238     - Host IP: 10.30.51.18
239     - portnames:
240         - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
241         - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
242         - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
243         - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
244         - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
245         - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
246         - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
247         - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
248         - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
249         - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
250  3. Server3 of Type-2:
251     - testbedname: testbed1.
252     - hostname: t1-tg1.
253     - CIMC IP: 10.30.50.16
254     - Host IP: 10.30.51.16
255     - portnames:
256         - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
257         - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
258         - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
259         - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
260         - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
261         - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
262         - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
263         - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
264         - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
265         - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
266         - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
267         - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
268  4. Server4 of Type-1:
269     - testbedname: testbed2.
270     - hostname: t2-sut1.
271     - CIMC IP: 10.30.50.21
272     - Host IP: 10.30.51.21
273     - portnames:
274         - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
275         - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
276         - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
277         - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
278         - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
279         - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
280         - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
281         - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
282         - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
283         - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
284  5. Server5 of Type-1:
285     - testbedname: testbed2.
286     - hostname: t2-sut2.
287     - CIMC IP: 10.30.50.22
288     - Host IP: 10.30.51.22
289     - portnames:
290         - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
291         - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
292         - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
293         - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
294         - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
295         - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
296         - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
297         - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
298         - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
299         - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
300  6. Server6 of Type-2:
301     - testbedname: testbed2.
302     - hostname: t2-tg1.
303     - CIMC IP: 10.30.50.20
304     - Host IP: 10.30.51.20
305     - portnames:
306         - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
307         - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
308         - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
309         - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
310         - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
311         - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
312         - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
313         - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
314         - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
315         - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
316         - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
317         - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
318  7. Server7 of Type-1:
319     - testbedname: testbed3.
320     - hostname: t3-sut1.
321     - CIMC IP: 10.30.50.25
322     - Host IP: 10.30.51.25
323     - portnames:
324         - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
325         - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
326         - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
327         - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
328         - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
329         - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
330         - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
331         - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
332         - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
333         - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
334  8. Server8 of Type-1:
335     - testbedname: testbed3.
336     - hostname: t3-sut2.
337     - CIMC IP: 10.30.50.26
338     - Host IP: 10.30.51.26
339     - portnames:
340         - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
341         - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
342         - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
343         - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
344         - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
345         - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
346         - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
347         - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
348         - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
349         - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
350  9. Server9 of Type-2:
351     - testbedname: testbed3.
352     - hostname: t3-tg1.
353     - CIMC IP: 10.30.50.24
354     - Host IP: 10.30.51.24
355     - portnames:
356         - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
357         - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
358         - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
359         - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
360         - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
361         - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
362         - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
363         - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
364         - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
365         - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
366         - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
367         - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
368 ```
369
370 ### Testbeds1,2,3 Network Connectivity
371
372 Listed nine servers are connected into the three of 3-node testbeds, testbed1,
373 testbed2 and testbed3, using defined naming convention as follows:
374
375 ```
376  1. testbed1:
377     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
378         - t1-tg1-c1/p1 to t1-sut1-c1/p2.
379         - t1-sut1-c1/p1 to t1-sut2-c1/p2.
380         - t1-sut2-c1/p1 to t1-tg1-c1/p2.
381     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
382         - t1-tg1-c2/p1 to t1-sut1-c2/p2.
383         - t1-sut1-c2/p1 to t1-sut2-c2/p2.
384         - t1-sut2-c2/p1 to t1-tg1-c2/p2.
385     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
386         - t1-tg1-c4/p1 to t1-sut1-c4/p2.
387         - t1-sut1-c4/p1 to t1-sut2-c4/p2.
388         - t1-sut2-c4/p1 to t1-tg1-c4/p2.
389     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
390         - t1-tg1-c5/p1 to t1-sut1-c5/p2.
391         - t1-sut1-c5/p1 to t1-sut2-c5/p2.
392         - t1-sut2-c5/p1 to t1-tg1-c5/p2.
393     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
394         - t1-tg1-c2/p1 to t1-sut1-cm/p2.
395         - t1-sut1-cm/p1 to t1-sut2-cm/p2.
396         - t1-sut2-cm/p1 to t1-tg1-c2/p2.
397     - TG loopback ports Intel NIC x710 2p10GE
398         - t1-tg1-c6/p1 to t1-tg1-c6/p2.
399
400  2. testbed2:
401     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
402         - t2-tg1-c1/p1 to t2-sut1-c1/p2.
403         - t2-sut1-c1/p1 to t2-sut2-c1/p2.
404         - t2-sut2-c1/p1 to t2-tg1-c1/p2.
405     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
406         - t2-tg1-c2/p1 to t2-sut1-c2/p2.
407         - t2-sut1-c2/p1 to t2-sut2-c2/p2.
408         - t2-sut2-c2/p1 to t2-tg1-c2/p2.
409     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
410         - t2-tg1-c4/p1 to t2-sut1-c4/p2.
411         - t2-sut1-c4/p1 to t2-sut2-c4/p2.
412         - t2-sut2-c4/p1 to t2-tg1-c4/p2.
413     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
414         - t2-tg1-c5/p1 to t2-sut1-c5/p2.
415         - t2-sut1-c5/p1 to t2-sut2-c5/p2.
416         - t2-sut2-c5/p1 to t2-tg1-c5/p2.
417     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
418         - t2-tg1-c2/p1 to t2-sut1-cm/p2.
419         - t2-sut1-cm/p1 to t2-sut2-cm/p2.
420         - t2-sut2-cm/p1 to t2-tg1-c2/p2.
421     - TG loopback ports Intel NIC x710 2p10GE
422         - t2-tg1-c6/p1 to t2-tg1-c6/p2.
423
424  3. testbed3:
425     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
426         - t3-tg1-c1/p1 to t3-sut1-c1/p2.
427         - t3-sut1-c1/p1 to t3-sut2-c1/p2.
428         - t3-sut2-c1/p1 to t3-tg1-c1/p2.
429     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
430         - t3-tg1-c2/p1 to t3-sut1-c2/p2.
431         - t3-sut1-c2/p1 to t3-sut2-c2/p2.
432         - t3-sut2-c2/p1 to t3-tg1-c2/p2.
433     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
434         - t3-tg1-c4/p1 to t3-sut1-c4/p2.
435         - t3-sut1-c4/p1 to t3-sut2-c4/p2.
436         - t3-sut2-c4/p1 to t3-tg1-c4/p2.
437     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
438         - t3-tg1-c5/p1 to t3-sut1-c5/p2.
439         - t3-sut1-c5/p1 to t3-sut2-c5/p2.
440         - t3-sut2-c5/p1 to t3-tg1-c5/p2.
441     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
442         - t3-tg1-c2/p1 to t3-sut1-cm/p2.
443         - t3-sut1-cm/p1 to t3-sut2-cm/p2.
444         - t3-sut2-cm/p1 to t3-tg1-c2/p2.
445     - TG loopback ports Intel NIC x710 2p10GE
446         - t3-tg1-c6/p1 to t3-tg1-c6/p2.
447 ```
448
449 ## Testbeds1,2,3 Server Specifications
450
451 ### Linux lscpu
452
453 ```
454  $ lscpu
455  Architecture:          x86_64
456  CPU op-mode(s):        32-bit, 64-bit
457  Byte Order:            Little Endian
458  CPU(s):                36
459  On-line CPU(s) list:   0-35
460  Thread(s) per core:    1
461  Core(s) per socket:    18
462  Socket(s):             2
463  NUMA node(s):          2
464  Vendor ID:             GenuineIntel
465  CPU family:            6
466  Model:                 63
467  Model name:            Intel(R) Xeon(R) CPU E5-2699 v3 @ 2.30GHz
468  Stepping:              2
469  CPU MHz:               2294.249
470  BogoMIPS:              4589.82
471  Virtualization:        VT-x
472  L1d cache:             32K
473  L1i cache:             32K
474  L2 cache:              256K
475  L3 cache:              46080K
476  NUMA node0 CPU(s):     0-17
477  NUMA node1 CPU(s):     18-35
478  Flags:                 fpu vme de pse tsc msr pae mce cx8 apic sep mtrr pge mca cmov pat pse36 clflush dts acpi mmx fxsr sse sse2 ss ht tm pbe syscall nx pdpe1gb rdtscp lm constant_tsc arch_perfmon pebs bts rep_good nopl xtopology nonstop_tsc aperfmperf eagerfpu pni pclmulqdq
479  dtes64 monitor ds_cpl vmx smx est tm2 ssse3 sdbg fma cx16 xtpr pdcm pcid dca sse4_1 sse4_2 x2apic movbe popcnt tsc_deadline_timer aes xsave avx f16c rdrand lahf_lm abm epb tpr_shadow vnmi flexpriority ept vpid fsgsbase tsc_adjust bmi1 avx2 smep bmi2 erms invpcid cqm xsaveopt
480  cqm_llc cqm_occup_llc dtherm arat pln pts
481 ```
482
483 ### Linux dmidecode pci
484
485 ```
486  $ dmidecode --type 9 | grep 'Handle\|Slot\|Type\|Address'
487  Handle 0x0046, DMI type 9, 17 bytes
488  System Slot Information
489      Designation: SlotID:1
490      Type: x8 PCI Express 3 x8
491      Bus Address: 0000:0a:02.0
492  Handle 0x0047, DMI type 9, 17 bytes
493  System Slot Information
494      Designation: SlotID:2
495      Type: x8 PCI Express 3 x8
496      Bus Address: 0000:0e:03.2
497  Handle 0x0048, DMI type 9, 17 bytes
498  System Slot Information
499      Designation: SlotID:3
500      Type: x8 PCI Express 3 x8
501      Bus Address: 0000:0d:03.0
502  Handle 0x0049, DMI type 9, 17 bytes
503  System Slot Information
504      Designation: SlotID:4
505      Type: x8 PCI Express 3 x8
506      Bus Address: 0000:85:02.2
507  Handle 0x004A, DMI type 9, 17 bytes
508  System Slot Information
509      Designation: SlotID:5
510      Type: x8 PCI Express 3 x16
511      Bus Address: 0000:87:03.0
512  Handle 0x004B, DMI type 9, 17 bytes
513  System Slot Information
514      Designation: SlotID:6
515      Type: x8 PCI Express 3 x8
516      Bus Address: 0000:84:02.0
517  Handle 0x004C, DMI type 9, 17 bytes
518  System Slot Information
519      Designation: SlotID:MLOM
520      Type: x8 Other
521      Bus Address: 0000:01:01.0
522  Handle 0x004D, DMI type 9, 17 bytes
523  System Slot Information
524      Designation: SlotID:HBA
525      Type: x8 Other
526      Bus Address: 0000:0c:02.2
527  Handle 0x004E, DMI type 9, 17 bytes
528  System Slot Information
529      Designation: SlotID:NVMe1
530      Type: x4 PCI Express 3 x4
531      Bus Address: 0000:82:01.0
532  Handle 0x004F, DMI type 9, 17 bytes
533  System Slot Information
534      Designation: SlotID:NVMe2
535      Type: x4 PCI Express 3 x4
536      Bus Address: 0000:83:01.1
537  Handle 0x0050, DMI type 9, 17 bytes
538  System Slot Information
539      Designation: SlotID:2.1
540      Type: x16 PCI Express 3 x16
541      Bus Address: 0000:00:1f.7
542  Handle 0x0051, DMI type 9, 17 bytes
543  System Slot Information
544      Designation: SlotID:2.2
545      Type: x16 PCI Express 3 x16
546      Bus Address: 0000:00:1f.7
547  Handle 0x0052, DMI type 9, 17 bytes
548  System Slot Information
549      Designation: SlotID:2.3
550      Type: x16 PCI Express 3 x16
551      Bus Address: 0000:00:1f.7
552  Handle 0x0053, DMI type 9, 17 bytes
553  System Slot Information
554      Designation: SlotID:2.4
555      Type: x16 PCI Express 3 x16
556      Bus Address: 0000:00:1f.7
557  Handle 0x0054, DMI type 9, 17 bytes
558  System Slot Information
559      Designation: SlotID:2.5
560      Type: x16 PCI Express 3 x16
561      Bus Address: 0000:00:1f.7
562  Handle 0x0055, DMI type 9, 17 bytes
563  System Slot Information
564      Designation: SlotID:5.1
565      Type: x8 PCI Express 3 x16
566      Bus Address: 0000:00:1f.7
567  Handle 0x0056, DMI type 9, 17 bytes
568  System Slot Information
569      Designation: SlotID:5.2
570      Type: x8 PCI Express 3 x16
571      Bus Address: 0000:00:1f.7
572  Handle 0x0057, DMI type 9, 17 bytes
573  System Slot Information
574      Designation: SlotID:5.3
575      Type: x8 PCI Express 3 x16
576      Bus Address: 0000:00:1f.7
577  Handle 0x0058, DMI type 9, 17 bytes
578  System Slot Information
579      Designation: SlotID:5.4
580      Type: x8 PCI Express 3 x16
581      Bus Address: 0000:00:1f.7
582  Handle 0x0059, DMI type 9, 17 bytes
583  System Slot Information
584      Designation: SlotID:5.5
585      Type: x8 PCI Express 3 x16
586      Bus Address: 0000:00:1f.7
587 ```
588
589 ### Linux dmidecode memory
590
591 ```
592  $ dmidecode -t memory
593  # dmidecode 2.12
594  SMBIOS 2.8 present.
595
596  Handle 0x0022, DMI type 16, 23 bytes
597  Physical Memory Array
598      Location: System Board Or Motherboard
599      Use: System Memory
600      Error Correction Type: Multi-bit ECC
601      Maximum Capacity: 1536 GB
602      Error Information Handle: Not Provided
603      Number Of Devices: 24
604
605  Handle 0x0024, DMI type 17, 34 bytes
606  Memory Device
607      Array Handle: 0x0022
608      Error Information Handle: Not Provided
609      Total Width: 72 bits
610      Data Width: 64 bits
611      Size: 32 GB
612      Form Factor: DIMM
613      Set: None
614      Locator: DIMM_A1
615      Bank Locator: NODE 0 CHANNEL 0 DIMM 0
616      Type: Other
617      Type Detail: None
618      Speed: 2133 MHz
619      Manufacturer: 0xAD00
620      Serial Number: 80EC7380
621      Asset Tag: DIMM_A1_AssetTag
622      Part Number: HMA84GL7MMR4N-TF
623      Rank: 4
624      Configured Clock Speed: 2133 MHz
625
626  Handle 0x0025, DMI type 17, 34 bytes
627  Memory Device
628      Array Handle: 0x0022
629      Error Information Handle: Not Provided
630      Total Width: 72 bits
631      Data Width: 64 bits
632      Size: 32 GB
633      Form Factor: DIMM
634      Set: None
635      Locator: DIMM_A2
636      Bank Locator: NODE 0 CHANNEL 0 DIMM 1
637      Type: Other
638      Type Detail: None
639      Speed: 2133 MHz
640      Manufacturer: 0xAD00
641      Serial Number: 80EC73D1
642      Asset Tag: DIMM_A2_AssetTag
643      Part Number: HMA84GL7MMR4N-TF
644      Rank: 4
645      Configured Clock Speed: 2133 MHz
646
647  Handle 0x0026, DMI type 17, 34 bytes
648  Memory Device
649      Array Handle: 0x0022
650      Error Information Handle: Not Provided
651      Total Width: Unknown
652      Data Width: Unknown
653      Size: No Module Installed
654      Form Factor: DIMM
655      Set: None
656      Locator: DIMM_A3
657      Bank Locator: NODE 0 CHANNEL 0 DIMM 2
658      Type: Other
659      Type Detail: None
660      Speed: Unknown
661      Manufacturer: NO DIMM
662      Serial Number: NO DIMM
663      Asset Tag: NO DIMM
664      Part Number: NO DIMM
665      Rank: Unknown
666      Configured Clock Speed: Unknown
667
668  Handle 0x0027, DMI type 17, 34 bytes
669  Memory Device
670      Array Handle: 0x0022
671      Error Information Handle: Not Provided
672      Total Width: 72 bits
673      Data Width: 64 bits
674      Size: 32 GB
675      Form Factor: DIMM
676      Set: None
677      Locator: DIMM_B1
678      Bank Locator: NODE 0 CHANNEL 1 DIMM 0
679      Type: Other
680      Type Detail: None
681      Speed: 2133 MHz
682      Manufacturer: 0xAD00
683      Serial Number: 80EC7325
684      Asset Tag: DIMM_B1_AssetTag
685      Part Number: HMA84GL7MMR4N-TF
686      Rank: 4
687      Configured Clock Speed: 2133 MHz
688
689  Handle 0x0028, DMI type 17, 34 bytes
690  Memory Device
691      Array Handle: 0x0022
692      Error Information Handle: Not Provided
693      Total Width: 72 bits
694      Data Width: 64 bits
695      Size: 32 GB
696      Form Factor: DIMM
697      Set: None
698      Locator: DIMM_B2
699      Bank Locator: NODE 0 CHANNEL 1 DIMM 1
700      Type: Other
701      Type Detail: None
702      Speed: 2133 MHz
703      Manufacturer: 0xAD00
704      Serial Number: 80EC7334
705      Asset Tag: DIMM_B2_AssetTag
706      Part Number: HMA84GL7MMR4N-TF
707      Rank: 4
708      Configured Clock Speed: 2133 MHz
709
710  Handle 0x0029, DMI type 17, 34 bytes
711  Memory Device
712      Array Handle: 0x0022
713      Error Information Handle: Not Provided
714      Total Width: Unknown
715      Data Width: Unknown
716      Size: No Module Installed
717      Form Factor: DIMM
718      Set: None
719      Locator: DIMM_B3
720      Bank Locator: NODE 0 CHANNEL 1 DIMM 2
721      Type: Other
722      Type Detail: None
723      Speed: Unknown
724      Manufacturer: NO DIMM
725      Serial Number: NO DIMM
726      Asset Tag: NO DIMM
727      Part Number: NO DIMM
728      Rank: Unknown
729      Configured Clock Speed: Unknown
730
731  Handle 0x002A, DMI type 17, 34 bytes
732  Memory Device
733      Array Handle: 0x0022
734      Error Information Handle: Not Provided
735      Total Width: 72 bits
736      Data Width: 64 bits
737      Size: 32 GB
738      Form Factor: DIMM
739      Set: None
740      Locator: DIMM_C1
741      Bank Locator: NODE 0 CHANNEL 2 DIMM 0
742      Type: Other
743      Type Detail: None
744      Speed: 2133 MHz
745      Manufacturer: 0xAD00
746      Serial Number: 80EC7329
747      Asset Tag: DIMM_C1_AssetTag
748      Part Number: HMA84GL7MMR4N-TF
749      Rank: 4
750      Configured Clock Speed: 2133 MHz
751
752  Handle 0x002B, DMI type 17, 34 bytes
753  Memory Device
754      Array Handle: 0x0022
755      Error Information Handle: Not Provided
756      Total Width: 72 bits
757      Data Width: 64 bits
758      Size: 32 GB
759      Form Factor: DIMM
760      Set: None
761      Locator: DIMM_C2
762      Bank Locator: NODE 0 CHANNEL 2 DIMM 1
763      Type: Other
764      Type Detail: None
765      Speed: 2133 MHz
766      Manufacturer: 0xAD00
767      Serial Number: 80EC732D
768      Asset Tag: DIMM_C2_AssetTag
769      Part Number: HMA84GL7MMR4N-TF
770      Rank: 4
771      Configured Clock Speed: 2133 MHz
772
773  Handle 0x002C, DMI type 17, 34 bytes
774  Memory Device
775      Array Handle: 0x0022
776      Error Information Handle: Not Provided
777      Total Width: Unknown
778      Data Width: Unknown
779      Size: No Module Installed
780      Form Factor: DIMM
781      Set: None
782      Locator: DIMM_C3
783      Bank Locator: NODE 0 CHANNEL 2 DIMM 2
784      Type: Other
785      Type Detail: None
786      Speed: Unknown
787      Manufacturer: NO DIMM
788      Serial Number: NO DIMM
789      Asset Tag: NO DIMM
790      Part Number: NO DIMM
791      Rank: Unknown
792      Configured Clock Speed: Unknown
793
794  Handle 0x002D, DMI type 17, 34 bytes
795  Memory Device
796      Array Handle: 0x0022
797      Error Information Handle: Not Provided
798      Total Width: 72 bits
799      Data Width: 64 bits
800      Size: 32 GB
801      Form Factor: DIMM
802      Set: None
803      Locator: DIMM_D1
804      Bank Locator: NODE 0 CHANNEL 3 DIMM 0
805      Type: Other
806      Type Detail: None
807      Speed: 2133 MHz
808      Manufacturer: 0xAD00
809      Serial Number: 80EC73D3
810      Asset Tag: DIMM_D1_AssetTag
811      Part Number: HMA84GL7MMR4N-TF
812      Rank: 4
813      Configured Clock Speed: 2133 MHz
814
815  Handle 0x002E, DMI type 17, 34 bytes
816  Memory Device
817      Array Handle: 0x0022
818      Error Information Handle: Not Provided
819      Total Width: 72 bits
820      Data Width: 64 bits
821      Size: 32 GB
822      Form Factor: DIMM
823      Set: None
824      Locator: DIMM_D2
825      Bank Locator: NODE 0 CHANNEL 3 DIMM 1
826      Type: Other
827      Type Detail: None
828      Speed: 2133 MHz
829      Manufacturer: 0xAD00
830      Serial Number: 80EC7330
831      Asset Tag: DIMM_D2_AssetTag
832      Part Number: HMA84GL7MMR4N-TF
833      Rank: 4
834      Configured Clock Speed: 2133 MHz
835
836  Handle 0x002F, DMI type 17, 34 bytes
837  Memory Device
838      Array Handle: 0x0022
839      Error Information Handle: Not Provided
840      Total Width: Unknown
841      Data Width: Unknown
842      Size: No Module Installed
843      Form Factor: DIMM
844      Set: None
845      Locator: DIMM_D3
846      Bank Locator: NODE 0 CHANNEL 3 DIMM 2
847      Type: Other
848      Type Detail: None
849      Speed: Unknown
850      Manufacturer: NO DIMM
851      Serial Number: NO DIMM
852      Asset Tag: NO DIMM
853      Part Number: NO DIMM
854      Rank: Unknown
855      Configured Clock Speed: Unknown
856
857  Handle 0x0030, DMI type 17, 34 bytes
858  Memory Device
859      Array Handle: 0x0022
860      Error Information Handle: Not Provided
861      Total Width: 72 bits
862      Data Width: 64 bits
863      Size: 32 GB
864      Form Factor: DIMM
865      Set: None
866      Locator: DIMM_E1
867      Bank Locator: NODE 1 CHANNEL 0 DIMM 0
868      Type: Other
869      Type Detail: None
870      Speed: 2133 MHz
871      Manufacturer: 0xAD00
872      Serial Number: 80E54252
873      Asset Tag: DIMM_E1_AssetTag
874      Part Number: HMA84GL7MMR4N-TF
875      Rank: 4
876      Configured Clock Speed: 2133 MHz
877
878  Handle 0x0031, DMI type 17, 34 bytes
879  Memory Device
880      Array Handle: 0x0022
881      Error Information Handle: Not Provided
882      Total Width: 72 bits
883      Data Width: 64 bits
884      Size: 32 GB
885      Form Factor: DIMM
886      Set: None
887      Locator: DIMM_E2
888      Bank Locator: NODE 1 CHANNEL 0 DIMM 1
889      Type: Other
890      Type Detail: None
891      Speed: 2133 MHz
892      Manufacturer: 0xAD00
893      Serial Number: 80E54235
894      Asset Tag: DIMM_E2_AssetTag
895      Part Number: HMA84GL7MMR4N-TF
896      Rank: 4
897      Configured Clock Speed: 2133 MHz
898
899  Handle 0x0032, DMI type 17, 34 bytes
900  Memory Device
901      Array Handle: 0x0022
902      Error Information Handle: Not Provided
903      Total Width: Unknown
904      Data Width: Unknown
905      Size: No Module Installed
906      Form Factor: DIMM
907      Set: None
908      Locator: DIMM_E3
909      Bank Locator: NODE 1 CHANNEL 0 DIMM 2
910      Type: Other
911      Type Detail: None
912      Speed: Unknown
913      Manufacturer: NO DIMM
914      Serial Number: NO DIMM
915      Asset Tag: NO DIMM
916      Part Number: NO DIMM
917      Rank: Unknown
918      Configured Clock Speed: Unknown
919
920  Handle 0x0033, DMI type 17, 34 bytes
921  Memory Device
922      Array Handle: 0x0022
923      Error Information Handle: Not Provided
924      Total Width: 72 bits
925      Data Width: 64 bits
926      Size: 32 GB
927      Form Factor: DIMM
928      Set: None
929      Locator: DIMM_F1
930      Bank Locator: NODE 1 CHANNEL 1 DIMM 0
931      Type: Other
932      Type Detail: None
933      Speed: 2133 MHz
934      Manufacturer: 0xAD00
935      Serial Number: 80E54218
936      Asset Tag: DIMM_F1_AssetTag
937      Part Number: HMA84GL7MMR4N-TF
938      Rank: 4
939      Configured Clock Speed: 2133 MHz
940
941  Handle 0x0034, DMI type 17, 34 bytes
942  Memory Device
943      Array Handle: 0x0022
944      Error Information Handle: Not Provided
945      Total Width: 72 bits
946      Data Width: 64 bits
947      Size: 32 GB
948      Form Factor: DIMM
949      Set: None
950      Locator: DIMM_F2
951      Bank Locator: NODE 1 CHANNEL 1 DIMM 1
952      Type: Other
953      Type Detail: None
954      Speed: 2133 MHz
955      Manufacturer: 0xAD00
956      Serial Number: 80E54236
957      Asset Tag: DIMM_F2_AssetTag
958      Part Number: HMA84GL7MMR4N-TF
959      Rank: 4
960      Configured Clock Speed: 2133 MHz
961
962  Handle 0x0035, DMI type 17, 34 bytes
963  Memory Device
964      Array Handle: 0x0022
965      Error Information Handle: Not Provided
966      Total Width: Unknown
967      Data Width: Unknown
968      Size: No Module Installed
969      Form Factor: DIMM
970      Set: None
971      Locator: DIMM_F3
972      Bank Locator: NODE 1 CHANNEL 1 DIMM 2
973      Type: Other
974      Type Detail: None
975      Speed: Unknown
976      Manufacturer: NO DIMM
977      Serial Number: NO DIMM
978      Asset Tag: NO DIMM
979      Part Number: NO DIMM
980      Rank: Unknown
981      Configured Clock Speed: Unknown
982
983  Handle 0x0036, DMI type 17, 34 bytes
984  Memory Device
985      Array Handle: 0x0022
986      Error Information Handle: Not Provided
987      Total Width: 72 bits
988      Data Width: 64 bits
989      Size: 32 GB
990      Form Factor: DIMM
991      Set: None
992      Locator: DIMM_G1
993      Bank Locator: NODE 1 CHANNEL 2 DIMM 0
994      Type: Other
995      Type Detail: None
996      Speed: 2133 MHz
997      Manufacturer: 0xAD00
998      Serial Number: 80E54247
999      Asset Tag: DIMM_G1_AssetTag
1000      Part Number: HMA84GL7MMR4N-TF
1001      Rank: 4
1002      Configured Clock Speed: 2133 MHz
1003
1004  Handle 0x0037, DMI type 17, 34 bytes
1005  Memory Device
1006      Array Handle: 0x0022
1007      Error Information Handle: Not Provided
1008      Total Width: 72 bits
1009      Data Width: 64 bits
1010      Size: 32 GB
1011      Form Factor: DIMM
1012      Set: None
1013      Locator: DIMM_G2
1014      Bank Locator: NODE 1 CHANNEL 2 DIMM 1
1015      Type: Other
1016      Type Detail: None
1017      Speed: 2133 MHz
1018      Manufacturer: 0xAD00
1019      Serial Number: 80E5421E
1020      Asset Tag: DIMM_G2_AssetTag
1021      Part Number: HMA84GL7MMR4N-TF
1022      Rank: 4
1023      Configured Clock Speed: 2133 MHz
1024
1025  Handle 0x0038, DMI type 17, 34 bytes
1026  Memory Device
1027      Array Handle: 0x0022
1028      Error Information Handle: Not Provided
1029      Total Width: Unknown
1030      Data Width: Unknown
1031      Size: No Module Installed
1032      Form Factor: DIMM
1033      Set: None
1034      Locator: DIMM_G3
1035      Bank Locator: NODE 1 CHANNEL 2 DIMM 2
1036      Type: Other
1037      Type Detail: None
1038      Speed: Unknown
1039      Manufacturer: NO DIMM
1040      Serial Number: NO DIMM
1041      Asset Tag: NO DIMM
1042      Part Number: NO DIMM
1043      Rank: Unknown
1044      Configured Clock Speed: Unknown
1045
1046  Handle 0x0039, DMI type 17, 34 bytes
1047  Memory Device
1048      Array Handle: 0x0022
1049      Error Information Handle: Not Provided
1050      Total Width: 72 bits
1051      Data Width: 64 bits
1052      Size: 32 GB
1053      Form Factor: DIMM
1054      Set: None
1055      Locator: DIMM_H1
1056      Bank Locator: NODE 1 CHANNEL 3 DIMM 0
1057      Type: Other
1058      Type Detail: None
1059      Speed: 2133 MHz
1060      Manufacturer: 0xAD00
1061      Serial Number: 80E5423C
1062      Asset Tag: DIMM_H1_AssetTag
1063      Part Number: HMA84GL7MMR4N-TF
1064      Rank: 4
1065      Configured Clock Speed: 2133 MHz
1066
1067  Handle 0x003A, DMI type 17, 34 bytes
1068  Memory Device
1069      Array Handle: 0x0022
1070      Error Information Handle: Not Provided
1071      Total Width: 72 bits
1072      Data Width: 64 bits
1073      Size: 32 GB
1074      Form Factor: DIMM
1075      Set: None
1076      Locator: DIMM_H2
1077      Bank Locator: NODE 1 CHANNEL 3 DIMM 1
1078      Type: Other
1079      Type Detail: None
1080      Speed: 2133 MHz
1081      Manufacturer: 0xAD00
1082      Serial Number: 80E5424D
1083      Asset Tag: DIMM_H2_AssetTag
1084      Part Number: HMA84GL7MMR4N-TF
1085      Rank: 4
1086      Configured Clock Speed: 2133 MHz
1087
1088  Handle 0x003B, DMI type 17, 34 bytes
1089  Memory Device
1090      Array Handle: 0x0022
1091      Error Information Handle: Not Provided
1092      Total Width: Unknown
1093      Data Width: Unknown
1094      Size: No Module Installed
1095      Form Factor: DIMM
1096      Set: None
1097      Locator: DIMM_H3
1098      Bank Locator: NODE 1 CHANNEL 3 DIMM 2
1099      Type: Other
1100      Type Detail: None
1101      Speed: Unknown
1102      Manufacturer: NO DIMM
1103      Serial Number: NO DIMM
1104      Asset Tag: NO DIMM
1105      Part Number: NO DIMM
1106      Rank: Unknown
1107      Configured Clock Speed: Unknown
1108 ```
1109
1110 ### Xeon Hsw Server BIOS Configuration
1111
1112 ```
1113  C240 / # scope bios
1114  C240 /bios # show advanced detail
1115  Set-up parameters:
1116     Intel(R) VT-d ATS Support: Enabled
1117     Adjacent Cache Line Prefetcher: Enabled
1118     All Onboard LOM Ports: Enabled
1119     Altitude: 300 M
1120     Bits per second: 115200
1121     Power Technology: Performance
1122     Channel Interleaving: Auto
1123     Intel(R) VT-d Coherency Support: Disabled
1124     Console Redirection: COM 0
1125     Number of Enabled Cores: All
1126     Energy Performance: Performance
1127     CPU Performance: Enterprise
1128     DCU IP Prefetcher: Enabled
1129     DCU Streamer Prefetch: Enabled
1130     Demand Scrub: Enabled
1131     Direct Cache Access Support: Auto
1132     Enhanced Intel Speedstep(R) Tec: Disabled
1133     Execute Disable: Enabled
1134     Flow Control: None
1135     Hardware Prefetcher: Enabled
1136     Intel(R) Hyper-Threading Techno: Disabled
1137     Intel(R) Turbo Boost Technology: Disabled
1138     Intel(R) VT: Enabled
1139     Intel(R) VT-d: Enabled
1140     Intel(R) Interrupt Remapping: Enabled
1141     Legacy USB Support: Enabled
1142     Extended APIC: XAPIC
1143     LOM Port 1 OptionROM: Enabled
1144     LOM Port 2 OptionROM: Enabled
1145     MMIO above 4GB: Enabled
1146     NUMA: Enabled
1147     PCI ROM CLP: Disabled
1148     Package C State Limit: C6 Retention
1149     Intel(R) Pass Through DMA: Disabled
1150     Patrol Scrub: Enabled
1151     xHCI Mode: Disabled
1152     All PCIe Slots OptionROM: Enabled
1153     PCIe Slot:1 OptionROM: Disabled
1154     PCIe Slot:2 OptionROM: Disabled
1155     PCIe Slot:3 OptionROM: Disabled
1156     PCIe Slot:4 OptionROM: Disabled
1157     PCIe Slot:5 OptionROM: Disabled
1158     PCIe Slot:6 OptionROM: Disabled
1159     PCIe Slot:HBA Link Speed: GEN3
1160     PCIe Slot:HBA OptionROM: Enabled
1161     PCIe Slot:MLOM OptionROM: Enabled
1162     PCIe Slot:N1 OptionROM: Enabled
1163     PCIe Slot:N2 OptionROM: Enabled
1164     Processor Power state C1 Enhanc: Disabled
1165     Processor C3 Report: Disabled
1166     Processor C6 Report: Disabled
1167     P-STATE Coordination: HW ALL
1168     Putty KeyPad: ESCN
1169     Energy Performance Tuning: BIOS
1170     QPI Link Frequency Select: Auto
1171     QPI Snoop Mode: Home Snoop
1172     Rank Interleaving: Auto
1173     Redirection After BIOS POST: Always Enable
1174     PCH SATA Mode: AHCI
1175     Select Memory RAS: Maximum Performance
1176     SR-IOV Support: Enabled
1177     Terminal Type: VT100
1178     Port 60/64 Emulation: Enabled
1179     Workload Configuration: Balanced
1180     CDN Support for VIC: Disabled
1181     Out-of-Band Management: Disabled
1182  C240-FCH1950V1H5 /bios/advanced #