196c956deaefdd8064837b5a6e514596caab2289
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14    1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
15    1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
16    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
17    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
19    1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
20    1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
21    1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
22 1. [Server Management](#server-management)
23    1. [Requirements](#requirements)
24    1. [Addressing](#addressing)
25    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
26    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
27 1. [Server Specifications](#server-specifications)
28    1. [Server Types](#server-types)
29    1. [Naming Convention](#naming-convention)
30 1. [Testbeds Configuration](#testbeds-configuration)
31    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
32       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
33       1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
34       1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
35       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
36       1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
37       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
38       1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
39       1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
40       1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
41       1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
42       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
43       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
44       1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
45       1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
46       1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
47       1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
48    1. [Per Testbed Wiring](#per-testbed-wiring)
49       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
50       1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
51       1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
52       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
53       1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
54       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
55       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
56       1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
57       1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
58       1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
59       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
60       1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
61       1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
62       1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
63       1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
64       1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
65 1. [Inventory](#inventory)
66    1. [Appliances](#appliances)
67    1. [Arm Servers](#arm-servers)
68    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
69    1. [Network Interface Cards](#network-interface-cards)
70    1. [Pluggables and Cables](#pluggables-and-cables)
71    1. [Other Parts](#other-parts)
72
73 ## Purpose
74
75 This note includes specification of the physical testbed infrastructure
76 hosted by LFN FD.io CSIT project.
77
78 ## Testbeds Overview
79
80 ### Summary List
81
82 ```
83  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx #snr
84  1. 1-Node-Haswell     nomad  hsw   na    4    4    0    4    0    0    0    0    0    0    0    0    0    0    0
85  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0    0    0    0
86  3. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0    0    0    0
87  4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0    1    0    0    0
88  5. 1-Node-AmpereAltra nomad  alt   na    2    2    0    0    0    0    0    0    0    0    2    0    0    0    0
89  6. 2-Node-Skylake     perf   skx   skx   3    3    3    0    6    0    0    0    0    0    0    0    0    0    0
90  7. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0    0    0    0
91  8. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0    0    0    0
92  9. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0    6    0    0    0
93 10. 2-Node-ThunderX2   perf   tx2   skx   1    1    .5   0    .5   0    0    0    1    0    0    0    0    0    0
94 11. 2-Node-Icelake     perf   icx   icx   4    4    4    0    0    0    0    0    0    0    0    0    0    8    0
95 12. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0    0    0    0
96 13. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0    0    0    0
97 14. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0    0    0    0
98 15. 3-Node-Altra       perf   alt   icx   1    2    .5   0    0    0    0    0    0    0    2    0    0    .5   0
99 16. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0    0    0    0
100 17. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    0    2    0    0
101 18. 3-Node-Icelake     perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    0    0    6    0
102 19. 3-Node-SnowRidge   perf   snr   icx   1    2    .5   0    0    0    0    0    0    0    0    0    0    .5   2
103                                  Totals: 34   44   21    4   17    1    2    3    3    2    4    7    2   15    2
104 ```
105
106 ### 1-Node-Skylake Xeon Intel (1n-skx)
107
108 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
109 ports connected back-to-back ([Server Types](#server-types)).
110 Used for FD.io VPP_Device functional driver tests.
111
112 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
113
114 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
115 ports connected back-to-back ([Server Types](#server-types)).
116 Used for FD.io VPP_Device functional driver tests.
117
118 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
119
120 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
121 NIC ports connected back-to-back ([Server Types](#server-types)).
122
123 Used for FD.io VPP_Device functional driver tests.
124
125 ### 2-Node-Skylake Xeon Intel (2n-skx)
126
127 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
128 (Server-Type-B2) connected in a 2-node circular topology
129 ([Server Types](#server-types)).
130 Used for FD.io performance tests.
131
132 ### 2-Node-Denverton Atom Intel (2n-dnv)
133
134 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
135 TG (Server-Type-B2) connected in a 2-node circular topology
136 ([Server Types](#server-types)).
137 Used for FD.io performance tests.
138
139 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
140
141 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
142 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
143 circular topology ([Server Types](#server-types)).
144 Used for FD.io TCP/IP and HTTP performance tests.
145
146 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
147
148 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
149 one TG (Server-Type-C3) connected in a 2-node circular topology
150 ([Server Types](#server-types)).
151 Used for FD.io performance tests.
152
153 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
154
155 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
156 one TG (Server-Type-D2) connected in a 2-node circular topology
157 ([Server Types](#server-types)).
158 Used for FD.io performance tests.
159
160 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
161
162 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
163 one TG (Server-Type-E31) connected in a 2-node circular topology
164 ([Server Types](#server-types)).
165 Used for FD.io performance tests.
166
167 ### 2-Node-Icelake Xeon Intel (2n-icx)
168
169 Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
170 one TG (Server-Type-F2) connected in a 2-node circular topology
171 ([Server Types](#server-types)).
172 Used for FD.io performance tests.
173
174 ### 3-Node-Haswell Xeon Intel (3n-hsw)
175
176 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
177 TG (Server-Type-A2) connected in a 3-node circular topology
178 ([Server Types](#server-types)).
179 Used for FD.io performance tests.
180
181 ### 3-Node-Skylake Xeon Intel (3n-skx)
182
183 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
184 TG (Server-Type-B2) connected in a 3-node circular topology.
185 Used for FD.io performance tests.
186
187 ### 3-Node-Rangeley Atom Testbeds
188
189 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
190 TG (Server-Type-2) connected in a 3-node circular topology
191 ([Server Types](#server-types)).
192 Used for FD.io performance tests.
193
194 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
195
196 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
197 TG (Server-Type-E31) connected in a 3-node circular topology
198 ([Server Types](#server-types)).
199 Used for FD.io performance tests.
200
201 ### 3-Node-Altra Arm Ampere (3n-alt)
202
203 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
204 TG (Server-Type-F4) connected in a 3-node circular topology
205 ([Server Types](#server-types)).
206 Used for FD.io performance tests.
207
208 ### 3-Node-Icelake Xeon Intel (3n-icx)
209
210 Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
211 TG (Server-Type-F3) connected in a 3-node circular topology
212 ([Server Types](#server-types)).
213 Used for FD.io performance tests.
214
215 ### 3-Node-SnowRidge Atom Intel (3n-snr)
216
217 Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
218 TG (Server-Type-F4) connected in a 3-node circular topology
219 ([Server Types](#server-types)).
220 Used for FD.io performance tests.
221
222
223 ## Server Management
224
225 ### Requirements
226
227 For management purposes, each server must have following two ports
228 connected to the management network:
229
230 ```
231 - 1GE IPMI port
232   - IPMI - Intelligent Platform Management Interface.
233   - Required for access to embedded server management with WebUI, CLI,
234     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
235 - 1GE/10GE/40GE management port
236   - hostOS management port for general system management.
237 ```
238
239 ### Addressing
240
241 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
242 Management port, which are connected to two different VLANs.
243
244 ```
245 1. LOM (IPMI) VLAN:
246     - Subnet: 10.30.50.0/24
247     - Gateway: 10.30.50.1
248     - Broadcast: 10.30.50.255
249     - DNS1: 199.204.44.24
250     - DNS2: 199.204.47.54
251 2. Management Vlan:
252     - Subnet: 10.30.51.0/24
253     - Gateway: 10.30.51.1
254     - Broadcast: 10.30.51.255
255     - DNS1: 199.204.44.24
256     - DNS2: 199.204.47.54
257 ```
258
259 To access these hosts, VPN connection is required.
260
261 ### LOM (IPMI) VLAN IP Addresses
262
263 Name         | Comment
264 ------------ | -------
265 10.30.50.0   | network
266 10.30.51.1   | Router
267 10.30.50.2   | LF Reserved
268 10.30.50.3   | LF Reserved
269 10.30.50.4   | LF Reserved
270 10.30.50.5   | LF Reserved
271 10.30.50.6   | LF Reserved
272 10.30.50.7   | LF Reserved
273 10.30.50.8   | LF Reserved
274 10.30.50.9   | LF Reserved
275 10.30.50.10  | LF Reserved
276 10.30.50.11  | LF Reserved
277 10.30.50.12  | LF Reserved
278 10.30.50.13  | LF Reserved
279 10.30.50.14  | LF Reserved
280 10.30.50.15  | LF Reserved
281 10.30.50.22  | s42-nomad
282 10.30.50.24  | s43-nomad
283 10.30.50.25  | s44-nomad
284 10.30.50.26  | s45-nomad
285 10.30.50.28  | s41-nomad
286 10.30.50.29  | s39-nomad
287 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
288 10.30.50.30  | s40-nomad
289 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
290 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
291 10.30.50.36  | s17-t33-sut1
292 10.30.50.37  | s18-t33-sut2
293 10.30.50.38  | fdio-marvell-dev
294 10.30.50.39  | s53-nomad
295 10.30.50.40  | s54-nomad
296 10.30.50.41  | s3-t21-sut1
297 10.30.50.42  | s4-t21-tg1
298 10.30.50.43  | s11-t31-sut1
299 10.30.50.44  | s12-t31-sut2
300 10.30.50.45  | s13-t31-tg1
301 10.30.50.46  | s19-t33t211-tg1
302 10.30.50.47  | s1-t11-sut1
303 10.30.50.48  | s2-t12-sut1
304 10.30.50.49  | s5-t22-sut1
305 10.30.50.50  | s6-t22-tg1
306 10.30.50.51  | s7-t23-sut1
307 10.30.50.52  | s8-t23-tg1
308 10.30.50.53  | s9-t24-sut1
309 10.30.50.54  | s10-t24-tg1
310 10.30.50.55  | s14-t32-sut1
311 10.30.50.56  | s15-t32-sut2
312 10.30.50.57  | s16-t32-tg1
313 10.30.50.58  | s25-t25-sut1
314 10.30.50.59  | s26-t25-tg1
315 10.30.50.65  | s52-nomad
316 10.30.50.66  | s51-nomad
317 10.30.50.67  | s49-nomad
318 10.30.50.68  | s50-nomad
319 10.30.50.69  | s27-t211-sut1
320 10.30.50.70  | s55-t13-sut1
321 10.30.50.71  | s56-t14-sut1
322 10.30.50.72  | s62-t34-sut1
323 10.30.50.73  | s63-t34-sut2
324 10.30.50.74  | s64-t34t36-tg1
325 10.30.50.75  | s65-t37-sut1
326 10.30.50.76  | s66-t37-sut2
327 10.30.50.77  | s67-t37-tg1
328 10.30.50.78  | s78-t38-sut1
329 10.30.50.79  | s79-t38-sut2
330 10.30.50.80  | s80-t38-tg1
331 10.30.50.81  | s71-t212-sut1
332 10.30.50.82  | s72-t212-tg1
333 10.30.50.83  | s83-t213-sut1
334 10.30.50.84  | s84-t213-tg1
335 10.30.50.85  | s85-t214-sut1
336 10.30.50.86  | s86-t214-tg1
337 10.30.50.87  | s87-t215-sut1
338 10.30.50.88  | s88-t215-tg1
339 10.30.50.89  | s89-t39t310-tg1
340 10.30.50.90  | s90-t311t312-tg1
341 10.30.50.91  | s58-nomad
342 10.30.50.92  | s59-nomad
343 10.30.50.93  | s93-t39-sut1
344 10.30.50.94  | s94-t39-sut2
345 10.30.50.255 | Broadcast
346 10.30.55.0   | network
347 10.30.55.1   | Router
348 10.30.55.10  | s28-t26t35-tg1
349 10.30.55.11  | s29-t26-sut1
350 10.30.55.12  | s30-t35-sut1
351 10.30.55.13  | s31-t35-sut2
352 10.30.55.14  | s46-nomad
353 10.30.55.15  | s47-nomad
354 10.30.55.16  | s48-nomad
355 10.30.55.17  | s57-nomad
356 10.30.55.18  | s33-t27-sut1
357 10.30.55.19  | s34-t27-tg1
358 10.30.55.20  | s35-t28-sut1
359 10.30.55.21  | s36-t28-tg1
360 10.30.55.22  | s37-t29-sut1
361 10.30.55.23  | s38-t29-tg1
362 10.30.55.24  | s60-t210-sut1
363 10.30.55.25  | s61-t210-tg1
364 10.30.55.255 | Broadcast
365
366 ### Management VLAN IP Addresses
367
368 Name         | Comment
369 -------------| -------
370 10.30.51.0   | network
371 10.30.51.1   | Router
372 10.30.51.2   | LF Reserved
373 10.30.51.3   | LF Reserved
374 10.30.51.4   | LF Reserved
375 10.30.51.5   | LF Reserved
376 10.30.51.6   | LF Reserved
377 10.30.51.7   | LF Reserved
378 10.30.51.8   | LF Reserved
379 10.30.51.15  | LF Reserved
380 10.30.51.22  | s42-nomad
381 10.30.51.24  | s43-nomad
382 10.30.51.25  | s44-nomad
383 10.30.51.26  | s45-nomad
384 10.30.51.28  | s41-nomad
385 10.30.51.29  | s39-nomad
386 10.30.51.30  | s40-nomad
387 10.30.51.36  | s17-t33-sut1
388 10.30.51.37  | s18-t33-sut2
389 10.30.51.38  | fdio-marvell-dev
390 10.30.51.39  | s53-nomad
391 10.30.51.40  | s54-nomad
392 10.30.51.44  | s3-t21-sut1
393 10.30.51.45  | s4-t21-tg1
394 10.30.51.46  | s11-t31-sut1
395 10.30.51.47  | s12-t31-sut2
396 10.30.51.48  | s13-t31-tg1
397 10.30.51.49  | s19-t33t211-tg1
398 10.30.51.50  | s1-t11-sut1
399 10.30.51.51  | s2-t12-sut1
400 10.30.51.52  | s5-t22-sut1
401 10.30.51.53  | s6-t22-tg1
402 10.30.51.54  | s7-t23-sut1
403 10.30.51.55  | s8-t23-tg1
404 10.30.51.56  | s9-t24-sut1
405 10.30.51.57  | s10-t24-tg1
406 10.30.51.58  | s14-t32-sut1
407 10.30.51.59  | s15-t32-sut2
408 10.30.51.60  | s16-t32-tg1
409 10.30.51.61  | s25-t25-sut1
410 10.30.51.62  | s26-t25-tg1
411 10.30.51.65  | s52-nomad
412 10.30.51.66  | s51-nomad
413 10.30.51.67  | s49-nomad
414 10.30.51.68  | s50-nomad
415 10.30.51.69  | s27-t211-sut1
416 10.30.51.70  | s55-t13-sut1
417 10.30.51.71  | s56-t14-sut1
418 10.30.51.72  | s62-t34-sut1
419 10.30.51.73  | s63-t34-sut2
420 10.30.51.74  | s64-t34t36-tg1
421 10.30.51.75  | s65-t37-sut1
422 10.30.51.76  | s66-t37-sut2
423 10.30.51.77  | s67-t37-tg1
424 10.30.51.78  | s78-t38-sut1
425 10.30.51.79  | s79-t38-sut2
426 10.30.51.80  | s80-t38-tg1
427 10.30.51.81  | s71-t212-sut1
428 10.30.51.82  | s72-t212-tg1
429 10.30.51.83  | s83-t213-sut1
430 10.30.51.84  | s84-t213-tg1
431 10.30.51.85  | s85-t214-sut1
432 10.30.51.86  | s86-t214-tg1
433 10.30.51.87  | s87-t215-sut1
434 10.30.51.88  | s88-t215-tg1
435 10.30.51.89  | s89-t39t310-tg1
436 10.30.51.90  | s90-t311t312-tg1
437 10.30.51.91  | s58-nomad
438 10.30.51.92  | s59-nomad
439 10.30.51.93  | s93-t39-sut1
440 10.30.51.94  | s94-t39-sut2
441 10.30.51.255 | Broadcast
442 10.32.8.0    | network
443 10.32.8.1    | Router
444 10.32.8.10   | s28-t26t35-tg1
445 10.32.8.11   | s29-t26-sut1
446 10.32.8.12   | s30-t35-sut1
447 10.32.8.13   | s31-t35-sut2
448 10.32.8.14   | s46-nomad
449 10.32.8.15   | s47-nomad
450 10.32.8.16   | s48-nomad
451 10.32.8.17   | s57-nomad
452 10.32.8.18   | s33-t27-sut1
453 10.32.8.19   | s34-t27-tg1
454 10.32.8.20   | s35-t28-sut1
455 10.32.8.21   | s36-t28-tg1
456 10.32.8.22   | s37-t29-sut1
457 10.32.8.23   | s38-t29-tg1
458 10.32.8.24   | s60-t210-sut1
459 10.32.8.25   | s61-t210-tg1
460 10.32.8.255  | Broadcast
461
462 ## Server Specifications
463
464 ### Server Types
465
466 FD.io CSIT lab contains following server types:
467 ```
468 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
469     - Quantity: 6 servers.
470     - Physical connectivity:
471         - CIMC and host management ports.
472         - NIC ports connected in 3-node topologies.
473     - Main HW configuration:
474         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
475         - Processors: 2* E5-2699v3 2.3 GHz.
476         - RAM Memory: 16* 32GB DDR4-2133MHz.
477         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
478     - NICs configuration:
479         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
480             - PCIe Slot1: empty.
481             - PCIe Slot2: empty.
482             - PCIe Slot3: empty.
483         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
484             - PCIe Slot4: empty.
485             - PCIe Slot5: empty.
486             - PCIe Slot6: empty
487         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
488 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
489     - Quantity: 3 servers.
490     - Physical connectivity:
491         - CIMC and host management ports.
492         - NIC ports connected in 3-node topologies.
493     - Main HW configuration:
494         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
495         - Processors: 2* E5-2699v3 2.3 GHz.
496         - RAM Memory: 16* 32GB DDR4-2133MHz.
497         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
498     - NICs configuration:
499         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
500             - PCIe Slot1: empty.
501             - PCIe Slot2: empty.
502             - PCIe Slot3: empty.
503         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
504             - PCIe Slot4: empty.
505             - PCIe Slot5: empty.
506             - PCIe Slot6: empty
507         - MLOM slot: empty.
508 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
509     - Quantity: 3 servers.
510     - Physical connectivity:
511         - CIMC and host management ports.
512         - no NIC ports, standalone setup.
513     - Main HW configuration:
514         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
515         - Processors: 2* E5-2699v3 2.3 GHz.
516         - RAM Memory: 16* 32GB DDR4-2133MHz.
517         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
518     - NICs configuration:
519         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
520             - no cards.
521         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
522             - no cards.
523         - MLOM slot: empty.
524 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
525     - Quantity: ---
526     - Physical connectivity:
527         - IPMI and host management ports.
528         - NIC ports connected into 2-node and 3-node topologies.
529     - Main HW configuration:
530         - Chassis: SuperMicro SYS-7049GP-TRT.
531         - Motherboard: SuperMicro X11DPG-QT.
532         - Processors: 2* Intel Platinum 8180 2.5 GHz.
533         - RAM Memory: 16* 16GB DDR4-2666MHz.
534         - Disks: 2* 1.6TB 6G SATA SSD.
535     - NICs configuration:
536         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
537             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
538             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
539             - PCIe Slot9 5e:00.xx: empty.
540         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
541             - PCIe Slot6 86:00.xx: empty.
542             - PCIe Slot8 af:00.xx: empty.
543             - PCIe Slot10 d8:00.xx: empty.
544 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
545     - Quantity: ---
546     - Physical connectivity:
547         - IPMI and host management ports.
548         - NIC ports connected into 2-node and 3-node topologies.
549     - Main HW configuration:
550         - Chassis: SuperMicro SYS-7049GP-TRT.
551         - Motherboard: SuperMicro X11DPG-QT.
552         - Processors: 2* Intel Platinum 8180 2.5 GHz.
553         - RAM Memory: 16* 16GB DDR4-2666MHz.
554         - Disks: 2* 1.6TB 6G SATA SSD.
555     - NICs configuration:
556         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
557             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
558             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
559             - PCIe Slot9 5e:00.xx: empty.
560         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
561             - PCIe Slot6 86:00.xx: empty.
562             - PCIe Slot8 af:00.xx: empty.
563             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
564 6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
565     - Quantity: TBD based on testbed allocation.
566     - Physical connectivity:
567         - Management: serial Port (usb) for console
568         - NIC ports connected into 2-node.
569     - Main HW configuration:
570         - Chassis: Netgate XG-2758-1u
571         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
572         - RAM Memory: 16GB ECC
573         - Disks: 150 GB
574     - NICs configuration:
575         - 2x 10Gb Intel 82599ES
576         - 4x 1GB Intel I354
577 7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
578     - Quantity: 2.
579     - Physical connectivity:
580         - IPMI and host management ports.
581         - NIC ports connected into 1-node topologies.
582     - Main HW configuration:
583         - Chassis: SuperMicro SYS-7049GP-TRT.
584         - Motherboard: SuperMicro X11DPG-QT.
585         - Processors: 2* Intel Platinum 8180 2.5 GHz.
586         - RAM Memory: 16* 16GB DDR4-2666MHz.
587         - Disks: 2* 1.6TB 6G SATA SSD.
588     - NICs configuration:
589         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
590             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
591             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
592             - PCIe Slot9 5e:00.xx: empty.
593         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
594             - PCIe Slot6 86:00.xx: empty.
595             - PCIe Slot8 af:00.xx: empty.
596             - PCIe Slot10 d8:00.xx: empty.
597 8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
598     - Quantity: 1.
599     - Physical connectivity:
600         - Host management interface: 10/100/1000-BaseT.
601         - 8-port 10GE SFP+ integrated NIC.
602     - Main HW configuration:
603         - Chassis: PS10GE4NG.
604         - Motherboard: SuperMicro X11DPG-QT.
605         - Processors: Quad-Core, Intel Processor.
606         - HW accelerators: FPGA offload.
607         - RAM Memory: 64GB.
608         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
609         - Physical Interfaces: 4 * 10GE SFP+.
610         - Operating System: Native IxOS.
611     - Interface configuration:
612         - Port-1: 10GE SFP+.
613         - Port-2: 10GE SFP+.
614         - Port-3: 10GE SFP+.
615         - Port-4: 10GE SFP+.
616 9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
617     - Quantity: 1.
618     - Physical connectivity:
619         - IPMI and host management ports.
620         - NIC ports.
621     - Main HW configuration:
622         - Chassis: SuperMicro SYS-7049GP-TRT.
623         - Motherboard: SuperMicro X11DPG-QT.
624         - Processors: 2* Intel Platinum 8180 2.5 GHz.
625         - RAM Memory: 16* 16GB DDR4-2666MHz.
626         - Disks: 2* 1.6TB 6G SATA SSD.
627     - NICs configuration:
628         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
629             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
630             - PCIe Slot4 3b:00.xx: empty.
631             - PCIe Slot9 5e:00.xx: empty.
632         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
633             - PCIe Slot6 86:00.xx: empty.
634             - PCIe Slot8 af:00.xx: empty.
635             - PCIe Slot10 d8:00.xx: empty.
636 10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
637     - Quantity: 4
638     - Physical connectivity:
639         - IPMI and host management ports.
640         - NIC ports.
641     - Main HW configuration:
642         - Chassis: SuperMicro SYS-E300-9A
643         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
644         - RAM Memory: 32GB ECC
645         - Disks: 480 GB
646     - NICs configuration:
647         - 2x 10Gb Intel x553 fiber ports
648         - 2x 10Gb Intel x553 copper ports
649         - 4x 1GB Intel I350 ports
650 11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
651     - Quantity: 1.
652     - Physical connectivity:
653         - IPMI and host management ports.
654         - NIC ports connected into 1-node testbed topologies.
655     - Main HW configuration:
656         - Chassis: SuperMicro SYS-7049GP-TRT.
657         - Motherboard: SuperMicro X11DPG-QT.
658         - Processors: 2* Intel Platinum 8280 2.7 GHz.
659         - RAM Memory: 12* 16GB DDR4-2933.
660         - Disks: 2* 1.92TB SATA SSD.
661     - NICs configuration:
662         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
663             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
664             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
665             - PCIe Slot9 5e:00.xx: empty.
666         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
667             - PCIe Slot6 86:00.xx: empty.
668             - PCIe Slot8 af:00.xx: empty.
669             - PCIe Slot10 d8:00.xx: empty.
670 12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
671     - Quantity: 3
672     - Physical connectivity:
673         - IPMI and host management ports.
674         - NIC ports connected into 2-node testbed topologies.
675     - Main HW configuration:
676         - Chassis: SuperMicro SYS-7049GP-TRT.
677         - Motherboard: SuperMicro X11DPG-QT.
678         - Processors: 2* Intel Gold 6252N 2.3 GHz.
679         - RAM Memory: 12* 16GB DDR4-2933.
680         - Disks: 2* 1.92TB SATA SSD.
681     - NICs configuration:
682         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
683             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
684             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
685             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
686         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
687             - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
688             - PCIe Slot8 af:00.xx: empty.
689             - PCIe Slot10 d8:00.xx: empty.
690 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
691     - Quantity: 3.
692     - Physical connectivity:
693         - IPMI and host management ports.
694         - NIC ports connected into 2-node testbed topologies.
695     - Main HW configuration:
696         - Chassis: SuperMicro SYS-7049GP-TRT.
697         - Motherboard: SuperMicro X11DPG-QT.
698         - Processors: 2* Intel Platinum 8280 2.7 GHz.
699         - RAM Memory: 12* 16GB DDR4-2933.
700         - Disks: 2* 1.92TB SATA SSD.
701     - NICs configuration:
702         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
703             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
704             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
705             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
706         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
707             - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
708             - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
709             - PCIe Slot10 d8:00.xx: empty.
710 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
711     - Quantity: 3.
712     - Physical connectivity:
713         - IPMI and host management ports.
714         - no NIC ports, standalone setup.
715     - Main HW configuration:
716         - Chassis: SuperMicro 1029P-WTRT.
717         - Motherboard: SuperMicro X11DDW-NT.
718         - Processors: 2* Intel Platinum 8280 2.7 GHz.
719         - RAM Memory: 12* 16GB DDR4-2933.
720         - Disks: 4* 1.92TB SATA SSD.
721     - NICs configuration:
722         - Numa0:
723             - no cards.
724         - Numa1:
725             - no cards.
726 15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
727     - Quantity: 1.
728     - Physical connectivity:
729         - IPMI and host management ports.
730         - NIC ports connected into 2-node testbed topologies.
731     - Main HW configuration:
732         - Chassis: SuperMicro AS-1114S-WTRT
733         - Processors: 1* AMD EPYC 7532 2.4 GHz.
734         - RAM Memory: 8* 32GB DDR4-2933.
735         - Disks: 1* 1TB SATA SSD.
736     - NICs configuration:
737         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
738             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
739             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
740             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
741 16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
742     - Quantity: 1.
743     - Physical connectivity:
744         - IPMI and host management ports.
745         - NIC ports connected into 2-node testbed topologies.
746     - Main HW configuration:
747         - Chassis: SuperMicro AS-1114S-WTRT
748         - Processors: 1* AMD EPYC 7532 2.4 GHz.
749         - RAM Memory: 8* 32GB DDR4-2933.
750         - Disks: 1* 1TB SATA SSD.
751     - NICs configuration:
752         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
753             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
754             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
755             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
756 17.  Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
757     - Quantity: 2
758     - Physical connectivity:
759         - IPMI and host management ports.
760         - NIC ports connected into 1-node topologies.
761     - Main HW configuration:
762         - Chassis: GIGABYTE Rack Mount
763         - Motherboard: MT91-FS4-00
764         - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
765         - RAM Memory: 16 * 16GB DIMM
766         - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
767     - NICs configuration:
768         - Numa0:
769             - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
770             - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
771         - Numa1:
772             - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
773             - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
774 18.  Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
775     - Quantity: 2
776     - Physical connectivity:
777         - IPMI(?) and host management ports.
778         - NIC ports connected into 3-node topology.
779     - Main HW configuration:
780         - Chassis: Huawei TaiShan 2280.
781         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
782         - RAM Memory: 8* 16GB DDR4-2400MT/s
783         - Disks: 1* 4TB SATA HDD
784     - NICs configuration:
785         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
786         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
787 19.  Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
788     - Quantity: 1
789     - Physical connectivity:
790         - IPMI and host management ports.
791         - NIC ports connected into 2-node topologies.
792     - Main HW configuration:
793         - Chassis: Gigabyte R181-T90 1U
794         - Motherboard: MT91-FS1
795         - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
796         - RAM Memory: 4* 32GB RDIMM
797         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
798     - NICs configuration:
799         - Numa0:
800             - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
801         - Numa1:
802             - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
803 20.  Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
804     - Quantity: 1
805     - Physical connectivity:
806         - IPMI and host management ports.
807         - NIC ports connected into 3-node topologies.
808     - Main HW configuration:
809         - Chassis: TBD
810         - Motherboard: TBD
811         - Processors: n* TBD
812         - RAM Memory: n* TBD
813         - Disks: TBD
814     - NICs configuration:
815         - Numa0:
816             - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
817             - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
818         - Numa1:
819             - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
820             - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
821 21.  Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
822     - Quantity: 1
823     - Physical connectivity:
824         - IPMI and host management ports.
825         - NIC ports connected into 2-node and 3-node topologies.
826     - Main HW configuration:
827         - Chassis: SuperMicro SYS-7049GP-TRT.
828         - Motherboard: SuperMicro X11DPG-QT.
829         - Processors: 2* Intel Platinum 8180 2.5 GHz.
830         - RAM Memory: 16* 16GB DDR4-2666MHz.
831         - Disks: 2* 1.6TB 6G SATA SSD.
832     - NICs configuration:
833         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
834             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
835             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
836             - PCIe Slot9 5e:00.xx: empty.
837         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
838             - PCIe Slot6 86:00.xx: empty.
839             - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
840             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
841 22. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
842     - Quantity: 8.
843     - Physical connectivity:
844         - IPMI and host management ports.
845         - NIC ports connected into 2-node or 3-node testbed topologies.
846     - Main HW configuration:
847         - Chassis: SuperMicro SYS-740GP-TNRT.
848         - Motherboard: Super X12DPG-QT6.
849         - Processors: 2* Intel Platinum 8358 2.6 GHz.
850         - RAM Memory: 16* 16GB DDR4-3200.
851         - Disks: 2* 960GB SATA SSD.
852     - NICs configuration:
853         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
854             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
855             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
856             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
857         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
858             - PCIe Slot6 86:00.xx: empty.
859             - PCIe Slot8 af:00.xx: empty.
860             - PCIe Slot10 d8:00.xx: empty.
861 23. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
862     - Quantity: 3.
863     - Physical connectivity:
864         - IPMI and host management ports.
865         - NIC ports connected into 2-node testbed topologies.
866     - Main HW configuration:
867         - Chassis: SuperMicro SYS-740GP-TNRT.
868         - Motherboard: Super X12DPG-QT6.
869         - Processors: 2* Intel Platinum 8358 2.6 GHz.
870         - RAM Memory: 16* 16GB DDR4-3200.
871         - Disks: 2* 960GB SATA SSD.
872     - NICs configuration:
873         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
874             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
875             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
876             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
877         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
878             - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
879             - PCIe Slot8 af:00.xx: empty.
880             - PCIe Slot10 d8:00.xx: empty.
881 24. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
882     - Quantity: 3.
883     - Physical connectivity:
884         - IPMI and host management ports.
885         - NIC ports connected into 3-node testbed topologies.
886     - Main HW configuration:
887         - Chassis: SuperMicro SYS-740GP-TNRT.
888         - Motherboard: Super X12DPG-QT6.
889         - Processors: 2* Intel Platinum 8358 2.6 GHz.
890         - RAM Memory: 16* 16GB DDR4-3200.
891         - Disks: 2* 960GB SATA SSD.
892     - NICs configuration:
893         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
894             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
895             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
896             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
897         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
898             - PCIe Slot6 86:00.xx: empty.
899             - PCIe Slot8 af:00.xx: empty.
900             - PCIe Slot10 d8:00.xx: empty.
901 25. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
902     - Quantity: 3.
903     - Physical connectivity:
904         - IPMI and host management ports.
905         - NIC ports connected into 2-node and/or 3-node testbed topologies.
906     - Main HW configuration:
907         - Chassis: SuperMicro SYS-740GP-TNRT.
908         - Motherboard: Super X12DPG-QT6.
909         - Processors: 2* Intel Platinum 8358 2.6 GHz.
910         - RAM Memory: 16* 16GB DDR4-3200.
911         - Disks: 2* 960GB SATA SSD.
912     - NICs configuration:
913         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
914             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
915             - PCIe Slot4 3b:00.xx: empty.
916             - PCIe Slot9 5e:00.xx: empty.
917         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
918             - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
919             - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
920             - PCIe Slot10 d8:00.xx: empty.
921 26. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
922     - Quantity: 2.
923     - Physical connectivity:
924         - IPMI and host management ports.
925     - Main HW configuration:
926         - Chassis: Gigabyte R152-P30-00 1U
927         - Motherboard: MP32-AR1-00
928         - Processors: 1* Ampere(R) Altra(R) Processor (Neoverse N1)
929         - RAM Memory: 4* 16GB RDIMM-3200MHz
930         - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
931 27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
932     - Quantity: 2
933     - Physical connectivity:
934         - IPMI and host management ports.
935         - NIC ports connected into 3-node testbed topology.
936     - Main HW configuration:
937         - Chassis: ?.
938         - Motherboard: ?.
939         - Processors: ?* Intel Atom P5362B 2.2 GHz.
940         - RAM Memory: ?* ?GB DDR4-2933.
941         - Disks: ?* ? SATA SSD.
942     - NICs configuration:
943         - Numa0: (x16, PCIe3.0 lane)
944             - PCIe Slot yy:00.xx: ?.
945 ```
946
947 ### Naming Convention
948
949 Following naming convention is used within this page to specify physical
950 connectivity and wiring across defined CSIT testbeds:
951
952 ```
953 - testbedname: testbedN.
954 - hostname:
955     - traffic-generator: tN-tgW.
956     - system-under-testX: tN-sutX.
957 - portnames:
958     - tN-tgW-cY/pZ.
959     - tN-sutX-cY/pZ.
960 - where:
961     - N - testbed number.
962     - tgW - server acts as traffic-generator with W index.
963     - sutX - server acts as system-under-test with X index.
964     - Y - PCIe slot number denoting a NIC card number within the host.
965     - Z - port number on the NIC card.
966 ```
967
968 ## Testbeds Configuration
969
970 ### Per Testbed Server Allocation and Naming
971
972 #### 1-Node-Skylake Servers (1n-skx) PROD
973
974 ```
975 - SUT [Server-Type-B6]:
976     - testbedname: testbed11.
977     - hostname: s1-t11-sut1.
978     - IPMI IP: 10.30.50.47
979     - Host IP: 10.30.51.50
980     - portnames:
981         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
982         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
983         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
984         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
985         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
986         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
987         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
988         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
989 - SUT [Server-Type-B6]:
990     - testbedname: testbed12.
991     - hostname: s2-t12-sut1.
992     - IPMI IP: 10.30.50.48
993     - Host IP: 10.30.51.51
994     - portnames:
995         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
996         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
997         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
998         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
999         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
1000         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
1001         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
1002         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
1003 ```
1004
1005 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
1006
1007 ```
1008 - SUT [Server-Type-E11]:
1009     - testbedname: testbed13
1010     - hostname: s55-t13-sut1
1011     - IPMI IP: 10.30.50.70
1012     - Host IP: 10.30.51.70
1013     - portnames:
1014         - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1015         - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1016         - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1017         - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1018         - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1019         - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1020         - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1021         - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1022 - SUT [Server-Type-E11]:
1023     - testbedname: testbed14
1024     - hostname: s56-t14-sut1
1025     - IPMI IP: 10.30.50.71
1026     - Host IP: 10.30.51.71
1027     - portnames:
1028         - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1029         - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1030         - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1031         - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1032         - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1033         - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1034         - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1035         - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1036 ```
1037
1038 #### 1-Node-Cascadelake Servers (1n-clx) PROD
1039
1040 ```
1041 - SUT [Server-Type-C1]:
1042     - testbedname: testbed11.
1043     - hostname: s32-t14-sut1.
1044     - IPMI IP: 10.30.55.17
1045     - Host IP: 10.32.8.17
1046     - portnames:
1047         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1048         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1049         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1050         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1051         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
1052         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
1053         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
1054         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
1055 ```
1056
1057 #### 2-Node-Skylake Servers (2n-skx) PROD
1058
1059 ```
1060 - SUT [Server-Type-B1]:
1061     - testbedname: testbed21.
1062     - hostname: s3-t21-sut1.
1063     - IPMI IP: 10.30.50.41
1064     - Host IP: 10.30.51.44
1065     - portnames:
1066         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1067         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1068         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1069         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1070         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1071         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1072 - TG [Server-Type-B2]:
1073     - testbedname: testbed21.
1074     - hostname: s4-t21-tg1.
1075     - IPMI IP: 10.30.50.42
1076     - Host IP: 10.30.51.45
1077     - portnames:
1078         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1079         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1080         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1081         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1082         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1083         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1084         - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1085         - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1086         - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1087         - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1088 - SUT [Server-Type-B1]:
1089     - testbedname: testbed22.
1090     - hostname: s5-t22-sut1.
1091     - IPMI IP: 10.30.50.49
1092     - Host IP: 10.30.51.52
1093     - portnames:
1094         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1095         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1096         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1097         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1098         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1099         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1100 - TG [Server-Type-B2]:
1101     - testbedname: testbed22.
1102     - hostname: s6-t22-tg1.
1103     - IPMI IP: 10.30.50.50
1104     - Host IP: 10.30.51.53
1105     - portnames:
1106         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1107         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1108         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1109         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1110         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1111         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1112         - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1113         - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1114         - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1115         - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1116 - SUT [Server-Type-B1]:
1117     - testbedname: testbed23.
1118     - hostname: s7-t23-sut1.
1119     - IPMI IP: 10.30.50.51
1120     - Host IP: 10.30.51.54
1121     - portnames:
1122         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1123         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1124         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1125         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1126         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1127         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1128 - TG [Server-Type-B2]:
1129     - testbedname: testbed23.
1130     - hostname: s8-t23-tg1.
1131     - IPMI IP: 10.30.50.52
1132     - Host IP: 10.30.51.55
1133     - portnames:
1134         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1135         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1136         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1137         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1138         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1139         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1140         - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1141         - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1142         - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1143         - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1144 - SUT [Server-Type-B1]:
1145     - testbedname: testbed24.
1146     - hostname: s9-t24-sut1.
1147     - IPMI IP: 10.30.50.53
1148     - Host IP: 10.30.51.56
1149     - portnames:
1150         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1151         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1152         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1153         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1154         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1155         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1156 - TG [Server-Type-B2]:
1157     - testbedname: testbed24.
1158     - hostname: s10-t24-tg1.
1159     - IPMI IP: 10.30.50.54
1160     - Host IP: 10.30.51.57
1161     - portnames:
1162         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1163         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1164         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1165         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1166         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1167         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1168         - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1169         - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1170         - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1171         - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1172 ```
1173
1174 #### 2-Node-Denverton Servers (2n-dnv) PROD
1175
1176 Note: ServerB28 (TG) is shared between testbed26 & testbed35
1177
1178 ```
1179 - TG [Server-Type-B2]:
1180     - testbednames: testbed26 and testbed35.
1181     - hostname: s28-t26t35-tg1.
1182     - IPMI IP: 10.30.55.10
1183     - Host IP: 10.32.8.10
1184     - portnames:
1185         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
1186         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
1187         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
1188         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
1189         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
1190         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
1191         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
1192         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
1193         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
1194         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
1195         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
1196         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
1197 - SUT [Server-Type-B10]:
1198     - testbednames: testbed26.
1199     - hostname: s29-t26-sut1.
1200     - IPMI IP: 10.30.55.11
1201     - Host IP: 10.32.8.11
1202     - portnames:
1203         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
1204         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
1205         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
1206         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
1207 ```
1208
1209 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
1210
1211 ```
1212 - SUT [Server-Type-B8]:
1213     - testbedname: testbed25.
1214     - hostname: s25-t25-sut1.
1215     - IPMI IP: 10.30.50.58
1216     - Host IP: 10.30.51.61
1217     - portnames:
1218         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1219         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1220         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1221         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1222 - TG [Server-Type-B7]:
1223     - testbedname: testbed25.
1224     - hostname: s26-t25-tg1.
1225     - IPMI IP: 10.30.50.59
1226     - Host IP: 10.30.51.62
1227     - portnames:
1228         - s26-t25-tg1-p1 - 10GE-port1.
1229         - s26-t25-tg1-p2 - 10GE-port2.
1230         - s26-t25-tg1-p3 - 10GE-port3.
1231         - s26-t25-tg1-p4 - 10GE-port4.
1232 ```
1233
1234 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1235
1236 ```
1237 - SUT [Server-Type-C2]:
1238     - testbedname: testbed27.
1239     - hostname: s33-t27-sut1.
1240     - IPMI IP: 10.30.55.18
1241     - Host IP: 10.32.8.18
1242     - portnames:
1243         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1244         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1245         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1246         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1247         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1248         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1249         - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1250         - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1251         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1252         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1253 - TG [Server-Type-C3]:
1254     - testbedname: testbed27.
1255     - hostname: s34-t27-tg1.
1256     - IPMI IP: 10.30.55.19
1257     - Host IP: 10.32.8.19
1258     - portnames:
1259         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1260         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1261         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1262         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1263         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1264         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1265         - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1266         - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1267         - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
1268         - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
1269         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1270         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1271 - SUT [Server-Type-C2]:
1272     - testbedname: testbed28.
1273     - hostname: s35-t28-sut1.
1274     - IPMI IP: 10.30.55.20
1275     - Host IP: 10.32.8.20
1276     - portnames:
1277         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1278         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1279         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1280         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1281         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1282         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1283         - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1284         - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1285         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1286         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1287 - TG [Server-Type-C3]:
1288     - testbedname: testbed28.
1289     - hostname: s36-t28-tg1.
1290     - IPMI IP: 10.30.55.21
1291     - Host IP: 10.32.8.21
1292     - portnames:
1293         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1294         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1295         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1296         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1297         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1298         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1299         - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1300         - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1301         - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
1302         - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
1303         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1304         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1305 - SUT [Server-Type-C2]:
1306     - testbedname: testbed29.
1307     - hostname: s37-t29-sut1.
1308     - IPMI IP: 10.30.55.22
1309     - Host IP: 10.32.8.22
1310     - portnames:
1311         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1312         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1313         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1314         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1315         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1316         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1317         - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1318         - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1319         - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1320         - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1321 - TG [Server-Type-C3]:
1322     - testbedname: testbed29.
1323     - hostname: s38-t29-tg1.
1324     - IPMI IP: 10.30.55.23
1325     - Host IP: 10.32.8.23
1326     - portnames:
1327         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1328         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1329         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1330         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1331         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1332         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1333         - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1334         - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1335         - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1336         - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1337 ```
1338
1339 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1340
1341 ```
1342 - SUT [Server-Type-D1]:
1343     - testbedname: testbed210.
1344     - hostname: s60-t210-sut1.
1345     - IPMI IP: 10.30.55.24
1346     - Host IP: 10.32.8.24
1347     - portnames:
1348         - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1349         - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1350         - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1351         - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1352         - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1353         - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1354         - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1355         - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1356 - TG [Server-Type-D2]:
1357     - testbedname: testbed210.
1358     - hostname: s61-t210-tg1.
1359     - IPMI IP: 10.30.55.25
1360     - Host IP: 10.32.8.25
1361     - portnames:
1362         - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1363         - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1364         - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1365         - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1366         - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1367         - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1368         - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1369         - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1370 ```
1371
1372 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1373
1374 Note: Server19 (TG) is shared between testbed33 & testbed211
1375
1376 ```
1377 - SUT [Server-Type-E22]:
1378     - testbedname: testbed211.
1379     - hostname: s27-t211-sut1.
1380     - IPMI IP: 10.30.50.69
1381     - Host IP: 10.30.51.69
1382     - portnames:
1383         - s27-t211-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1384         - s27-t211-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1385         - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1386         - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1387 - TG [Server-Type-E31]:
1388     - testbedname: testbed33 and testbed211.
1389     - hostname: s19-t33t211-tg1.
1390     - IPMI IP: 10.30.50.46
1391     - Host IP: 10.30.51.49
1392     - portnames:
1393         - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1394         - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1395         - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1396         - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1397         - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1398         - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1399         - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1400         - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1401         - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1402         - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1403         - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1404         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1405 ```
1406
1407 #### 2-Node-Icelake Servers (2n-icx) PROD
1408
1409 ```
1410 - SUT [Server-Type-F1]:
1411     - testbedname: testbed212.
1412     - hostname: s71-t212-sut1.
1413     - IPMI IP: 10.30.51.81
1414     - Host IP: 10.30.50.81
1415     - portnames:
1416         - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1417         - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1418         - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1419         - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1420         - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1421         - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1422         - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1423         - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1424 - TG [Server-Type-F2]:
1425     - testbedname: testbed212.
1426     - hostname: s72-t212-tg1.
1427     - IPMI IP: 10.30.51.82
1428     - Host IP: 10.30.50.82
1429     - portnames:
1430         - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1431         - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1432         - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1433         - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1434         - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1435         - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1436         - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1437         - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1438         - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1439         - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1440 - SUT [Server-Type-F1]:
1441     - testbedname: testbed213.
1442     - hostname: s83-t213-sut1.
1443     - IPMI IP: 10.30.51.83
1444     - Host IP: 10.30.50.83
1445     - portnames:
1446         - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1447         - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1448         - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1449         - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1450         - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1451         - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1452         - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1453         - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1454 - TG [Server-Type-F2]:
1455     - testbedname: testbed213.
1456     - hostname: s84-t213-tg1.
1457     - IPMI IP: 10.30.51.84
1458     - Host IP: 10.30.50.84
1459     - portnames:
1460         - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1461         - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1462         - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1463         - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1464         - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1465         - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1466         - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1467         - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1468         - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1469         - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1470 - SUT [Server-Type-F1]:
1471     - testbedname: testbed214.
1472     - hostname: s85-t214-sut1.
1473     - IPMI IP: 10.30.51.85
1474     - Host IP: 10.30.50.85
1475     - portnames:
1476         - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1477         - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1478         - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1479         - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1480         - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1481         - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1482         - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1483         - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1484 - TG [Server-Type-F2]:
1485     - testbedname: testbed214.
1486     - hostname: s86-t214-tg1.
1487     - IPMI IP: 10.30.51.86
1488     - Host IP: 10.30.50.86
1489     - portnames:
1490         - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1491         - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1492         - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1493         - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1494         - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1495         - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1496         - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1497         - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1498         - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1499         - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1500 - SUT [Server-Type-F1]:
1501     - testbedname: testbed215.
1502     - hostname: s87-t215-sut1.
1503     - IPMI IP: 10.30.51.87
1504     - Host IP: 10.30.50.87
1505     - portnames:
1506         - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1507         - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1508         - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1509         - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1510         - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1511         - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1512         - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1513         - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1514 - TG [Server-Type-F2]:
1515     - testbedname: testbed215.
1516     - hostname: s88-t215-tg1.
1517     - IPMI IP: 10.30.51.88
1518     - Host IP: 10.30.50.88
1519     - portnames:
1520         - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1521         - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1522         - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1523         - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1524         - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1525         - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1526         - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1527         - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1528         - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1529         - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1530 ```
1531
1532 #### 3-Node-Skylake Servers (3n-skx) PROD
1533
1534 ```
1535 - ServerB11 [Server-Type-B1]:
1536     - testbedname: testbed31.
1537     - hostname: s11-t31-sut1.
1538     - IPMI IP: 10.30.50.43
1539     - Host IP: 10.30.51.46
1540     - portnames:
1541         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1542         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1543         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1544         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1545         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1546         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1547 - ServerB12 [Server-Type-B1]:
1548     - testbedname: testbed31.
1549     - hostname: s12-t31-sut2.
1550     - IPMI IP: 10.30.50.44
1551     - Host IP: 10.30.51.47
1552     - portnames:
1553         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1554         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1555         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1556         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1557         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1558         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1559 - ServerB13 [Server-Type-B2]:
1560     - testbedname: testbed31.
1561     - hostname: s13-t31-tg1.
1562     - IPMI IP: 10.30.50.45
1563     - Host IP: 10.30.51.48
1564     - portnames:
1565         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1566         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1567         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1568         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1569         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1570         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1571         - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1572         - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1573         - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1574         - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1575 - ServerB14 [Server-Type-B1]:
1576     - testbedname: testbed32.
1577     - hostname: s14-t32-sut1.
1578     - IPMI IP: 10.30.50.55
1579     - Host IP: 10.30.51.58
1580     - portnames:
1581         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1582         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1583         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1584         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1585         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1586         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1587 - ServerB15 [Server-Type-B1]:
1588     - testbedname: testbed32.
1589     - hostname: s15-t32-sut2.
1590     - IPMI IP: 10.30.50.56
1591     - Host IP: 10.30.51.59
1592     - portnames:
1593         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1594         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1595         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1596         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1597         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1598         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1599 - ServerB16 [Server-Type-B2]:
1600     - testbedname: testbed32.
1601     - hostname: s16-t32-tg1.
1602     - IPMI IP: 10.30.50.57
1603     - Host IP: 10.30.51.60
1604     - portnames:
1605         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1606         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1607         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1608         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1609         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1610         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1611         - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1612         - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1613         - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1614         - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1615 ```
1616
1617 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1618
1619 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1620
1621 ```
1622 - ServerB22 [Server-Type-B5]:
1623     - testbedname: testbed35.
1624     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1625     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1626     - Host IP: 10.30.51.9
1627     - portnames:
1628         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1629         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1630     - 1GB ports (tbd)
1631 - ServerB23 [Server-Type-B5]:
1632     - testbedname: testbed35.
1633     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1634     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1635     - Host IP: 10.30.51.10
1636     - portnames:
1637         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1638         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1639     - 1GB ports (tbd)
1640 - ServerB24 [Server-Type-B5]:
1641     - testbedname: testbed35.
1642     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1643     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1644     - Host IP: 10.30.51.11
1645     - portnames:
1646         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1647         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1648     - 1GB ports (tbd)
1649 ```
1650
1651 #### 3-Node-Taishan Servers (3n-tsh) PROD
1652
1653 Note: Server19 (TG) is shared between testbed33 & testbed211
1654
1655 ```
1656 - SUT [Server-Type-E21]:
1657     - testbedname: testbed33.
1658     - hostname: s17-t33-sut1.
1659     - IPMI IP: 10.30.50.36
1660     - Host IP: 10.30.51.36
1661     - portnames:
1662         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1663         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1664         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1665         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1666 - SUT [Server-Type-E21]:
1667     - testbedname: testbed33.
1668     - hostname: s18-t33-sut2.
1669     - IPMI IP: 10.30.50.37
1670     - Host IP: 10.30.51.37
1671     - portnames:
1672         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1673         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1674         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1675         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1676 - TG [Server-Type-E31]:
1677     - testbedname: testbed33 and testbed211.
1678     - hostname: s19-t33t211-tg1.
1679     - IPMI IP: 10.30.50.46
1680     - Host IP: 10.30.51.49
1681     - portnames:
1682         - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1683         - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1684         - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1685         - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1686         - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1687         - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1688         - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1689         - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1690         - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1691         - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1692         - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1693         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1694 ```
1695
1696 #### 3-Node-Altra Servers (3n-alt) PROD
1697
1698 Note: Server64 (TG) is shared between testbed34 & testbed36
1699
1700 ```
1701 - SUT [Server-Type-E23]:
1702     - testbedname: testbed34.
1703     - hostname: s62-t34-sut1.
1704     - IPMI IP: 10.30.50.72
1705     - Host IP: 10.30.51.72
1706     - portnames:
1707         - s62-t34-sut1-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1708         - s62-t34-sut1-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1709         - s62-t34-sut1-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
1710         - s62-t34-sut1-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
1711 - SUT [Server-Type-E23]:
1712     - testbedname: testbed34.
1713     - hostname: s63-t34-sut2.
1714     - IPMI IP: 10.30.50.73
1715     - Host IP: 10.30.51.73
1716     - portnames:
1717         - s63-t34-sut2-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1718         - s63-t34-sut2-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1719         - s63-t34-sut2-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
1720         - s63-t34-sut2-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
1721 - TG [Server-Type-F4]:
1722     - testbedname: testbed34.
1723     - hostname: s64-t34t36-tg1.
1724     - IPMI IP: 10.30.50.74
1725     - Host IP: 10.30.51.74
1726     - portnames:
1727         - s64-t34-tg1-c1/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1728         - s64-t34-tg1-c1/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1729 ```
1730
1731 #### 3-Node-Denverton Servers (3n-dnv) PROD
1732
1733 ```
1734 - ServerB30 [Server-Type-B10]:
1735     - testbednames: testbed35.
1736     - hostname: s30-t35-sut1.
1737     - IPMI IP: 10.30.55.12
1738     - Host IP: 10.32.8.12
1739     - portnames:
1740         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1741         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1742         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1743         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1744 - ServerB31 [Server-Type-B10]:
1745     - testbednames: testbed35.
1746     - hostname: s31-t35-sut2.
1747     - IPMI IP: 10.30.55.13
1748     - Host IP: 10.32.8.13
1749     - portnames:
1750         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1751         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1752         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1753         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1754 ```
1755
1756 #### 3-Node-Icelake Servers (3n-icx) PROD
1757
1758 ```
1759 - ServerF1 [Server-Type-F1]:
1760     - testbedname: testbed37.
1761     - hostname: s65-t37-sut1.
1762     - IPMI IP: 10.30.50.75
1763     - Host IP: 10.30.51.75
1764     - portnames:
1765         - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1766         - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1767         - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1768         - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1769         - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1770         - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1771         - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1772         - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1773 - ServerF1 [Server-Type-F1]:
1774     - testbedname: testbed37.
1775     - hostname: s66-t37-sut2.
1776     - IPMI IP: 10.30.50.76
1777     - Host IP: 10.30.51.76
1778     - portnames:
1779         - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1780         - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1781         - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1782         - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1783         - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1784         - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1785         - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1786         - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1787 - ServerF3 [Server-Type-F3]:
1788     - testbedname: testbed37.
1789     - hostname: s67-t37-tg1.
1790     - IPMI IP: 10.30.50.77
1791     - Host IP: 10.30.51.77
1792     - portnames:
1793         - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1794         - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1795         - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1796         - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1797         - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1798         - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1799         - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1800         - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1801 - ServerF1 [Server-Type-F1]:
1802     - testbedname: testbed38.
1803     - hostname: s78-t38-sut1.
1804     - IPMI IP: 10.30.50.78
1805     - Host IP: 10.30.51.78
1806     - portnames:
1807         - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1808         - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1809         - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1810         - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1811         - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1812         - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1813         - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1814         - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1815 - ServerF1 [Server-Type-F1]:
1816     - testbedname: testbed38.
1817     - hostname: s79-t38-sut2.
1818     - IPMI IP: 10.30.50.79
1819     - Host IP: 10.30.51.79
1820     - portnames:
1821         - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1822         - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1823         - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1824         - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1825         - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1826         - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1827         - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1828         - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1829 - ServerF3 [Server-Type-F3]:
1830     - testbedname: testbed38.
1831     - hostname: s80-t38-tg1.
1832     - IPMI IP: 10.30.50.80
1833     - Host IP: 10.30.51.80
1834     - portnames:
1835         - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1836         - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1837         - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1838         - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1839         - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1840         - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1841         - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1842         - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1843 ```
1844
1845 #### 3-Node-SnowRidge Servers (3n-snr) PROD
1846
1847 ```
1848 - ServerG1 [Server-Type-G1]:
1849     - testbedname: testbed39.
1850     - hostname: s93-t39-sut1.
1851     - IPMI IP: 10.30.50.93
1852     - Host IP: 10.30.51.93
1853     - portnames:
1854         - s93-t39-sut1-c1/p1 - 100GE-port1 e810-DA2-2p100GE.
1855         - s93-t39-sut1-c1/p2 - 100GE-port2 e810-DA2-2p100GE.
1856 - ServerG1 [Server-Type-G1]:
1857     - testbedname: testbed39.
1858     - hostname: s94-t39-sut2.
1859     - IPMI IP: 10.30.50.94
1860     - Host IP: 10.30.51.94
1861     - portnames:
1862         - s94-t39-sut2-c1/p1 - 100GE-port1 e810-DA2-2p100GE.
1863         - s94-t39-sut2-c1/p2 - 100GE-port1 e810-DA2-2p100GE.
1864 - ServerF4 [Server-Type-F4]:
1865     - testbedname: testbed39.
1866     - hostname: s89-t39t310-tg1.
1867     - IPMI IP: 10.30.50.89
1868     - Host IP: 10.30.51.89
1869     - portnames:
1870         - s89-t39t310-tg1-c6/p1 - 100GE-port1 e810-DA2-2p100GE.
1871         - s89-t39t310-tg1-c6/p2 - 100GE-port1 e810-DA2-2p100GE.
1872 ```
1873
1874 ### Per Testbed Wiring
1875
1876 #### 1-Node-Skylake Wiring (1n-skx) PROD
1877
1878 ```
1879 - testbed11:
1880     - ring1 10GE-ports x710-4p10GE:
1881         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1882     - ring2 10GE-ports x710-4p10GE:
1883         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1884     - ring3 10GE-ports x710-4p10GE:
1885         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1886     - ring4 10GE-ports x710-4p10GE:
1887         - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1888     - ring5 100GE-ports e810-2p100GE:
1889         - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1890     - ring6 100GE-ports e810-2p100GE:
1891         - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1892 - testbed12:
1893     - ring1 10GE-ports x710-4p10GE:
1894         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1895     - ring2 10GE-ports x710-4p10GE:
1896         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1897     - ring3 10GE-ports x710-4p10GE:
1898         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1899     - ring4 10GE-ports x710-4p10GE:
1900         - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1901     - ring5 100GE-ports e810-2p100GE:
1902         - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1903     - ring6 100GE-ports e810-2p100GE:
1904         - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1905 ```
1906
1907 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1908
1909 ```
1910 - testbed13:
1911     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1912         - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1913     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1914         - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1915     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1916         - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1917     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1918         - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1919
1920 - testbed14:
1921     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1922         - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1923     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1924         - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1925     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1926         - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1927     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1928         - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1929 ```
1930
1931 #### 2-Node-Skylake Wiring (2n-skx) PROD
1932
1933 ```
1934 - testbed21:
1935     - ring1 10GE-ports x710-4p10GE on SUT:
1936         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1937         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1938     - ring2 10GE-ports x710-4p10GE on SUT:
1939         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1940         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1941     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1942         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1943         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1944     - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1945         - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
1946         - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
1947 - testbed22:
1948     - ring1 10GE-ports x710-4p10GE on SUT:
1949         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1950         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1951     - ring2 10GE-ports x710-4p10GE on SUT:
1952         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1953         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1954     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1955         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1956         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1957     - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1958         - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
1959         - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
1960 - testbed23:
1961     - ring1 10GE-ports x710-4p10GE on SUT:
1962         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1963         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1964     - ring2 10GE-ports x710-4p10GE on SUT:
1965         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1966         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1967     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1968         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1969         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1970     - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1971         - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
1972         - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
1973 - testbed24:
1974     - ring1 10GE-ports x710-4p10GE on SUT:
1975         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1976         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1977     - ring2 10GE-ports x710-4p10GE on SUT:
1978         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1979         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1980     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1981         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1982         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1983     - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1984         - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
1985         - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
1986 ```
1987
1988 #### 2-Node-Denverton Wiring (2n-dnv) PROD
1989
1990 ```
1991 - testbed26:
1992     - ring1 10GE-ports x553 copper port on SUT:
1993         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1994         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1995     - ring2 10GE-ports x553 fiber port on SUT:
1996         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1997         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1998 ```
1999
2000 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
2001
2002 ```
2003 - testbed25:
2004     - link1 10GE-port x710-4p10GE on SUT:
2005         - t25-tg1-p1 to t25-sut1-c2/p1.
2006     - link2 10GE-port x710-4p10GE on SUT:
2007         - t25-tg1-p2 to t25-sut1-c2/p2.
2008     - link3 10GE-port x710-4p10GE on SUT:
2009         - t25-tg1-p3 to t25-sut1-c2/p3.
2010     - link4 10GE-port x710-4p10GE on SUT:
2011         - t25-tg1-p4 to t25-sut1-c2/p4.
2012 ```
2013
2014 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
2015
2016 ```
2017 - testbed27:
2018     - ring1 10GE-ports x710-4p10GE on SUT:
2019         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
2020         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
2021     - ring2 10GE-ports x710-4p10GE on SUT:
2022         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
2023         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
2024     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2025         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
2026         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
2027     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2028         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
2029         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
2030     - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
2031         - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
2032         - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
2033     - ring6 100GE-ports e810-2p100GE on TG:
2034         - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
2035         - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
2036 - testbed28:
2037     - ring1 10GE-ports x710-4p10GE on SUT:
2038         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
2039         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
2040     - ring2 10GE-ports x710-4p10GE on SUT:
2041         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
2042         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
2043     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2044         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
2045         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
2046     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2047         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
2048         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
2049     - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
2050         - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
2051         - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
2052     - ring6 100GE-ports e810-2p100GE on TG:
2053         - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
2054         - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
2055 - testbed29:
2056     - ring1 10GE-ports x710-4p10GE on SUT:
2057         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
2058         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
2059     - ring2 10GE-ports x710-4p10GE on SUT:
2060         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
2061         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
2062     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2063         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
2064         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
2065     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2066         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
2067         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
2068     - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
2069         - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
2070         - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
2071 ```
2072
2073 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
2074
2075 ```
2076 - testbed210:
2077     - ring1 10GE-ports x710-4p10GE on SUT:
2078         - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
2079         - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
2080     - ring2 10GE-ports x710-4p10GE on SUT:
2081         - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
2082         - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
2083     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2084         - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
2085         - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
2086     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2087         - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
2088         - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
2089 ```
2090
2091 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
2092
2093 ```
2094 - testbed211:
2095     - ring1 10GE-ports x520-2p10GE on SUTs:
2096         - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
2097         - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
2098 ```
2099
2100 #### 2-Node-Icelake Wiring (2n-icx) PROD
2101
2102 ```
2103 - testbed212:
2104     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2105         - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
2106         - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
2107     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2108         - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
2109         - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
2110         - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
2111         - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
2112     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2113         - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
2114         - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
2115     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2116         - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
2117         - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
2118 - testbed213:
2119     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2120         - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
2121         - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
2122     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2123         - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
2124         - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
2125         - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
2126         - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
2127     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2128         - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
2129         - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
2130     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2131         - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
2132         - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
2133 - testbed214:
2134     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2135         - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
2136         - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
2137     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2138         - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
2139         - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
2140         - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
2141         - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
2142     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2143         - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
2144         - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
2145     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2146         - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
2147         - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
2148 - testbed215:
2149     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2150         - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
2151         - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
2152     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2153         - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
2154         - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
2155         - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
2156         - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
2157     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2158         - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
2159         - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
2160     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2161         - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
2162         - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
2163 ```
2164
2165 #### 3-Node-Skylake Wiring (3n-skx) PROD
2166
2167 ```
2168 - testbed31:
2169     - ring1 10GE-ports x710-4p10GE on SUTs:
2170         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
2171         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
2172         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
2173     - ring2 10GE-ports x710-4p10GE on SUT:
2174         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
2175         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
2176         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
2177     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2178         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
2179         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
2180         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
2181     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
2182         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
2183         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
2184         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
2185     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
2186         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
2187         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
2188 - testbed32:
2189     - ring1 10GE-ports x710-4p10GE on SUTs:
2190         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
2191         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
2192         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
2193     - ring2 10GE-ports x710-4p10GE on SUT:
2194         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
2195         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
2196         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
2197     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2198         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
2199         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
2200         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
2201     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
2202         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
2203         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
2204         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
2205     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
2206         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
2207         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
2208 ```
2209
2210 #### 3-Node-Rangeley Wiring (3n-rng) VERIFY
2211
2212 ```
2213 To be completed.
2214 ```
2215
2216 #### 3-Node-Taishan Wiring (3n-tsh) PROD
2217
2218 ```
2219 - testbed33:
2220     - ring1 10GE-ports x520-2p10GE on SUTs:
2221         - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
2222         - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
2223         - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
2224     - ring2 25GE-ports cx4-2p25GE on SUTs:
2225         - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
2226         - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
2227         - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
2228 ```
2229
2230 #### 3-Node-Altra Wiring (3n-alt) PROD
2231
2232 ```
2233 - testbed34:
2234     - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
2235         - s64-t34-tg1-cn/p2 - s62-t34-sut1-cn/p2.
2236         - s62-t34-sut1-cn/p1 - s63-t34-sut2-cn/p2.
2237         - s63-t34-sut2-cn/p1 - s64-t34-tg1-cn/p1.
2238     - ring2 100GE-ports ConnectX5-2p100GE on SUTs:
2239         - s64-t34-tg1-ck/p2 - s62-t34-sut1-ck/p2.
2240         - s62-t34-sut1-ck/p1 - s63-t34-sut2-ckp2.
2241         - s63-t34-sut2-ck/p1 - s64-t34-tg1-ck/p1.
2242 ```
2243
2244 #### 3-Node-Denverton Wiring (3n-dnv) PROD
2245
2246 ```
2247 - testbed35:
2248     - ring1 10GE-ports x553 copper port on SUTs:
2249         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
2250         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
2251         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
2252     - ring2 10GE-ports x553 fiber port on SUTs:
2253         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
2254         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
2255         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
2256 ```
2257
2258 #### 3-Node-Icelake Wiring (3n-icx) PROD
2259
2260 ```
2261 - testbed37:
2262     - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
2263         - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
2264         - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
2265         - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
2266     - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
2267         - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
2268         - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
2269         - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
2270         - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
2271         - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
2272         - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
2273     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
2274         - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
2275         - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
2276         - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
2277 - testbed38:
2278     - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
2279         - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
2280         - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
2281         - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
2282     - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
2283         - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
2284         - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
2285         - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
2286         - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
2287         - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
2288         - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
2289     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
2290         - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
2291         - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
2292         - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
2293 ```
2294
2295 #### 3-Node-SnowRidge Wiring (3n-snr) PROD
2296
2297 ```
2298 - testbed39:
2299     - ring1 100GE-ports e810-DA2-2p100GE on SUTs and TG:
2300         - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
2301         - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
2302         - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
2303 ```
2304
2305 ## Inventory
2306
2307 ### Appliances
2308
2309 ```
2310 1. Ixia PerfectStorm One Appliance
2311     - 1 * PS10GE4NG
2312         - Chassis: PS10GE4NG.
2313         - Motherboard: SuperMicro X11DPG-QT.
2314         - Processors: Quad-Core, Intel Processor.
2315         - HW accelerators: FPGA offload.
2316         - RAM Memory: 64GB.
2317         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
2318         - Physical Interfaces: 4 * 10GE SFP+.
2319         - Operating System: Native IxOS.
2320 ```
2321
2322 ### Arm Servers
2323
2324 ```
2325 1. Arm Cortex A-72 servers
2326     - 2 * ThunderX2 (VPP Device)
2327         - Chassis: GIGABYTE Rack Mount
2328         - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
2329         - RAM Memory: 16* 16GB DIMM
2330         - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
2331     - 1 * ThunderX2 (Performance)
2332         - Chassis: GIGABYTE Rack Mount
2333         - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
2334         - RAM Memory: 4* 32GB RDIMM
2335         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
2336     - 2 * Huawei TaiShan 2280.
2337         - Chassis: Huawei TaiShan 2280.
2338         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
2339         - RAM Memory: 8* 16GB DDR4-2400MT/s.
2340         - Disks: 1* 4TB SATA HDD.
2341     - 2 * Ampere Altra
2342         - Chassis: TBD
2343         - Processors: TBD
2344         - RAM Memory: TBD
2345         - Disks: TBD
2346 ```
2347
2348 ### Xeon and Atom Servers
2349
2350 ```
2351 1. Intel Xeon servers:
2352     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
2353         - Chassis: SuperMicro SYS-7049GP-TRT.
2354         - Motherboard: SuperMicro X11DPG-QT.
2355         - Processors: 2* Intel Platinum 8180 2.5 GHz.
2356         - RAM Memory: 16* 16GB DDR4-2666MHz.
2357         - Disks: 2* 1.6TB 6G SATA SSD.
2358 2. Intel Atom servers with Rangely processors.
2359     - 3 * Netgate XG-2758-1u
2360         - Chassis: Netgate XG-2758-1u
2361         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
2362         - RAM Memory: 16GB ECC
2363         - Disks: 150 GB
2364 ```
2365
2366 ### Network Interface Cards
2367
2368 ```
2369 1. 10GE NICs
2370     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
2371     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
2372     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
2373 2. 25GE NICs
2374     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
2375 3. 40GE NICs
2376     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
2377 4. 100GE NICs
2378     - 4 * mcx556a-edat NICs (not on site yet, in transit)
2379 ```
2380
2381 ### Pluggables and Cables
2382
2383 Pluggables:
2384
2385 ```
2386 1. 10GE SFP+
2387     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
2388     - 80 * 10G SR optic (generic, "Intel" compatible branded)
2389 2. 25GE SFP28
2390     - None
2391 3. 40GE QSFP+
2392     - None
2393 4. 100GE
2394     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
2395 ```
2396
2397 Standalone cables:
2398
2399 ```
2400 1. 10GE
2401     - None
2402 2. 25GE
2403     - None
2404 3. 40GE QSFP+
2405     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
2406 4. 100GE
2407     - None
2408 ```
2409
2410 ### Other Parts